Plans_TS-0007.pdf
PDF 23 MB Posted
- Attached to
- Tinker Lift Station Elimination, Area A
- Solicitation number
- TS-0007
- Issued by
- Oklahoma County, Oklahoma City, Oklahoma
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Anti Noncollusion Affidavit.pdf | ||
| Business Relationship Affidavit.pdf | ||
| TS-0007 Volume 1-Specs.pdf | ||
| TS-0007 Volume 2-Supplemental Provisions-TAFB.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
AL
E:
A S
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
EE
T
O F
C
IV
IL
D
AT
2-
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
1 109.03 AUDIO-VIDEO RECORDING PRE-CONSTRUCTION AND POST-CONSTRUCTION L.S. 1
2 109.05 SEDIMENT AND EROSION CONTROL L.S. 1
3 212 TRENCH EXCAVATION AND BACKFILL (0-10 FEET) L.F. 551
4 212 TRENCH EXCAVATION AND BACKFILL (0-15 FEET) L.F. 944
5 212 TRENCH EXCAVATION AND BACKFILL (0-20 FEET) L.F. 552
6 215 EMBEDMENT MATERIAL C.Y. 507
7 252 BORE AND STEEL ENCASEMENT (8-INCH CARRIER) L.F. 347
8 513 HYDROSTATIC PRESSURE TESTING L.S. 1
9 602 SEWER SERVICE CONNECTIONS E.A. 9
10 603 SEWER SERVICE LINE (4-INCH) L.F. 169
11 604 ABANDONING SEWER C.Y. 17
12 604 SEWER REMOVAL L.F. 107
13 608 SEWER FLOW CONTROL L.S. 1
14 613 DEFLECTION TEST (<24-INCHES) L.S. 1
15 615 SEWER LEAKAGE TEST (<24-INCHES) L.S. 1
16 616 (4-FOOT DIA.) SANITARY SEWER MANHOLE (0-6 FEET) E.A. 10
17 616 EXTRA DEPTH MANHOLE WALL (4-FOOT DIA.) V.F. 67
18 616 4-INCH MANHOLE DROP CONNECTION E.A 1
19 617 MANHOLE TESTING (ON LINES <24-INCHES) L.S. 1
20 629 ABANDONING MANHOLE E.A. 3
21 633 PVC SDR-35 SANITARY SEWER PIPE (8-INCH) L.F. 1,794
22 633 PVC C900 DR-18 SANITARY SEWER PIPE (8-INCH) L.F. 321
22 633 PVC SDR-35 SANITARY SEWER PIPE (4-INCH) L.F. 241
24 801 GPS AS-BUILT AND SURVEY L.S. 1
25 801 CONSTRUCTION STAKING (CONSTRUCTION SURVEY) L.S. 1
26 802 CONSTRUCTION SIGNING AND TRAFFIC CONTROL L.S. 1
27 810 SELECTIVE CLEARING AND GRUBBING L.S. 1
28 811 ABANDONING EXISTING LIFT STATION L.S. 4
29 811 EXISTING AERIAL CREEK CROSSING REMOVAL L.S. 1
30 814 PAVEMENT CUT AND PERMANENT REPAIR (ASPHALT) S.Y. 564
31 816 REMOVE (AND REPLACE) SIDEWALK (CONCRETE) S.Y. 2
32 840 SOLID SLAB SODDING S.Y. 5,580
33 SPT 1.3H FLOW METER AND ACCESSORIES E.A. 1
(6)
(7)(8)(9)
(10)(11)
PA
Y
IT
EM
N O
TE
AC
(5)
(9)(12)(14)
(4)
(3)
(2)
(13) (4)
TOPOGRAPHIC LEGEND
(1)
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\1400390-AC01.dwg
AutoCAD SHX Text
5/19/2025 9:13 AM
AutoCAD SHX Text
1) CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING AND SUBMITTING CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLETING AND SUBMITTING PRE-CONSTRUCTION AND POST-CONSTRUCTION DVDS OF THE PROJECT EXTENTS. THE RECORDINGS SHALL BE COLOR AUDIO-VIDEO AND RECORDED ON TWO SEPARATE DVD RECORDINGS. ONE DVD FOR POST-CONSTRUCTION AND ONE DVD FOR PRE-CONSTRUCTION. RECORDING SHALL INCLUDE ALL PROJECT LIMITS, STORAGE AREAS, AND OTHER AREAS CONTRACTOR OR ENGINEER DETERMINE PERTINENT. 2) THE COST OF ALL LABOR AND MATERIALS (UNLESS PAY ITEMS PROVIDED) REQUIRED FOR THE COST OF ALL LABOR AND MATERIALS (UNLESS PAY ITEMS PROVIDED) REQUIRED FOR THE INSTALLATION OF EROSION CONTROL MEASURES SHALL BE INCLUDED IN THE BID PRICE FOR THIS ITEM. THE CONTRACTOR SHALL IMPLEMENT EROSION CONTROL MEASURES AS NECESSARY TO PREVENT SEDIMENT FROM ENTERING THE STORM SEWER SYSTEM. PREVENT SEDIMENT FROM ENTERING THE STORM SEWER SYSTEM. 3) THE COST FOR THE STEEL CASING PIPE, CARRIER PIPE, EXCAVATION, BACKFILL, THE COST FOR THE STEEL CASING PIPE, CARRIER PIPE, EXCAVATION, BACKFILL, SHEETING, SHORING, BRACING, DRAINAGE, DISPOSAL OF ALL SURPLUS MATERIALS, TEMPORARY DAMS, AND BYPASS PUMPS, LABOR, TOOLS, EQUIPMENT, AND INCIDENTALS NECESSARY TO COMPLETE THIS WORK SHALL BE INCLUDED IN THIS PAY ITEM. 4) THE QUANTITIES ARE ESTIMATED AND THE CONTRACTOR IS RESPONSIBLE FOR LOCATING THE QUANTITIES ARE ESTIMATED AND THE CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL SERVICE CONNECTIONS AND CONNECTING IT TO THE NEW SEWER LINE. SEE GENERAL NOTE 15 FOR ADDITIONAL INFORMATION 5) PRICE BID TO INCLUDE COST ASSOCIATED WITH ESTABLISHING AND MAINTAINING PROJECT PRICE BID TO INCLUDE COST ASSOCIATED WITH ESTABLISHING AND MAINTAINING PROJECT EASEMENT OR RIGHT-OF-WAY LIMITS, VERTICAL CONTROL, AND HORIZONTAL CONTROL INCLUDING REFERENCE POINTS AND GPS AS-BUILT INFORMATION. SEE GENERAL NOTE 14 ON AC02 FOR ADDITIONAL INFORMATION. 6) THE COST OF ALL LABOR AND MATERIALS REQUIRED TO ADEQUATELY CONTROL TRAFFIC THE COST OF ALL LABOR AND MATERIALS REQUIRED TO ADEQUATELY CONTROL TRAFFIC DURING CONSTRUCTION SHALL BE INCLUDED IN THE BID PRICE FOR THIS ITEM. ALL TRAFFIC CONTROL DEVICES USED AND THEIR PLACEMENT SHALL CONFORM TO THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, CURRENT EDITION. SEE GENERAL NOTE 20 ON AC02 FOR ADDITIONAL INFORMATION. 7) USE TYPE A AGGREGATE TO BACKFILL EXCAVATION UNDER STREETS, DRIVES, AND CURB. USE TYPE A AGGREGATE TO BACKFILL EXCAVATION UNDER STREETS, DRIVES, AND CURB. COST OF BACKFILL TO BE INCLUDED IN BID PRICE FOR REMOVAL AND REPLACEMENT ITEMS. 8) THE QUANTITY OF TYPE A AGGREGATE BACKFILL IN TRENCH UNDER PAVEMENT AND THE QUANTITY OF TYPE A AGGREGATE BACKFILL IN TRENCH UNDER PAVEMENT AND AROUND MANHOLES IS INCLUDED IN PAVEMENT CUT AND REPAIR AND NOT A SEPARATE PAY ITEM. 9) THE COST OF SAW CUTTING PAVEMENT SHALL BE INCLUDED IN PAVEMENT CUT AND THE COST OF SAW CUTTING PAVEMENT SHALL BE INCLUDED IN PAVEMENT CUT AND PERMANENT REPAIR. 10) COST OF WATERING TO BE INCLUDED IN THE BID PRICE FOR SODDING. CONTRACTOR TO COST OF WATERING TO BE INCLUDED IN THE BID PRICE FOR SODDING. CONTRACTOR TO SUPPLY ADEQUATE WATERING TO PROMOTE GRASS GROWTH AND IN A MANNER APPROVED BY THE ENGINEER. 11) CONTRACTOR RESPONSIBLE FOR SODDING ALL DISTURBED GRASSY AREAS. SEE ALSO CONTRACTOR RESPONSIBLE FOR SODDING ALL DISTURBED GRASSY AREAS. SEE ALSO NOTES PERTAINING TO SPECIAL GOLF COURSE SOD MATERIALS. 12) ALL INSIDE SURFACES OF PRE-CAST CONCRETE MANHOLES MUST BE SHOP COATED NOT ALL INSIDE SURFACES OF PRE-CAST CONCRETE MANHOLES MUST BE SHOP COATED NOT LESS THAN 8 MILS ACCORDING TO PAY ITEM SECTION 616. NON-VENTED MANHOLES MUST BE SHOP COATED NOT LESS THAN 100 MILS. 13) ABANDONED SEWER SHALL BE FILLED WITH FLOWABLE FILL. ABANDONED SEWER SHALL BE FILLED WITH FLOWABLE FILL. 14) MANHOLE LIDS ARE TO BE PER DETAIL 13, SHEET 616.D OR NON-VENTED PER DETAIL 14, MANHOLE LIDS ARE TO BE PER DETAIL 13, SHEET 616.D OR NON-VENTED PER DETAIL 14, SHEET 616.E.
AutoCAD SHX Text
%%UPAY ITEM NOTES
AutoCAD SHX Text
NO.
AutoCAD SHX Text
ITEM
AutoCAD SHX Text
UNIT
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
ESTIMATED QUANTITIES
AutoCAD SHX Text
SPEC. NO.
AutoCAD SHX Text
PAY ITEM
AutoCAD SHX Text
NOTE
AutoCAD SHX Text A) THE COST OF ANY TEMPORARY FENCING AND THE REMOVAL AND REPLACEMENT OF ALL THE COST OF ANY TEMPORARY FENCING AND THE REMOVAL AND REPLACEMENT OF ALL FENCES, RETAINING WALLS, MISCELLANEOUS FOOTINGS, CONCRETE AND BRING PLANTERS, SHEDS, CONCRETE PADS, PORTABLE BUILDINGS, AND OTHER MISCELLANEOUS ITEMS SHALL BE CONSIDERED INCIDENTAL. FENCES AND OTHER ITEMS REMOVED DURING CONSTRUCTION SHALL BE REPLACED IN AS GOOD OR BETTER CONDITION. B) EARTHWORK REQUIRED TO REPLACE AND FILL AROUND MANHOLES, ANY REQUIRED EARTHWORK REQUIRED TO REPLACE AND FILL AROUND MANHOLES, ANY REQUIRED BORROW TO FILL AROUND MANHOLES, AND RE-CONNECTING EXISTING PIPE TO A REPLACED OR REHABILITATED MANHOLE SHALL BE CONSIDERED INCIDENTAL. C) THE CONTRACTOR IS RESPONSIBLE FOR ENSURING ANY OPEN EXCAVATION IS PROPERLY THE CONTRACTOR IS RESPONSIBLE FOR ENSURING ANY OPEN EXCAVATION IS PROPERLY DEWATERED. THE COST FOR DEWATERING SHALL BE CONSIDERED INCIDENTAL. D) EXISTING SEWER PIPE REMOVAL IN THE OPEN TRENCH FOR THE INSTALLATION OF THE NEW EXISTING SEWER PIPE REMOVAL IN THE OPEN TRENCH FOR THE INSTALLATION OF THE NEW SEWER SHALL BE CONSIDERED INCIDENTAL. E) CURB AND GUTTER REPAIRS SHALL BE CONSIDERED INCIDENTAL IN THE PROCESS OF CURB AND GUTTER REPAIRS SHALL BE CONSIDERED INCIDENTAL IN THE PROCESS OF PAVEMENT CUT AND PERMANENT REPLACEMENT. F) ALL COSTS NOT ASSOCIATED WITH A PAY ITEM SHALL BE CONSIDERED INCIDENTAL AND ALL COSTS NOT ASSOCIATED WITH A PAY ITEM SHALL BE CONSIDERED INCIDENTAL AND COVERED IN OTHER PAY ITEMS. G) SEE DRAWING NOTES PERTAINING TO INDIVIDUAL LIFT STATIONS. SEE DRAWING NOTES PERTAINING TO INDIVIDUAL LIFT STATIONS. H) TREE ROOT PROTECTION MEASURES ARE CONSIDERED INCIDENTAL TO TRENCH EXCAVATION TREE ROOT PROTECTION MEASURES ARE CONSIDERED INCIDENTAL TO TRENCH EXCAVATION CONSTRUCTION ACTIVITIES. SEE DETAIL A3 ON SHEET C500. C500. . I) SANITARY SEWER CLEANOUTS, WYE CONNECTIONS, AND TAPS ARE CONSIDERED INCIDENTAL SANITARY SEWER CLEANOUTS, WYE CONNECTIONS, AND TAPS ARE CONSIDERED INCIDENTAL WITH SANITARY SEWER SERVICE CONNECTIONS. J) FENCING ASSOCIATED WITH TREE ROOT PROTECTION SHALL BE INCLUDED IN ESTIMATED FENCING ASSOCIATED WITH TREE ROOT PROTECTION SHALL BE INCLUDED IN ESTIMATED QUANTITY ITEM NO. 2, SEDIMENT AND EROSION CONTROL.
AutoCAD SHX Text
%%UINCIDENTAL NOTES
AutoCAD SHX Text
SANITARY SEWER MANHOLE (EXISTING)
AutoCAD SHX Text
SANITARY SEWER CLEANOUT (EXISTING)
AutoCAD SHX Text
SIGN/TRAFFIC/UTILITY
AutoCAD SHX Text
SANITARY SEWER UNDERGROUND (EXISTING)
AutoCAD SHX Text
SANITARY SEWER UNDERGROUND (EXISTING - ASSUMED LOCATION)
AutoCAD SHX Text
WATERLINE UNDERGROUND
AutoCAD SHX Text
POWER ELECTRIC OVERHEAD
AutoCAD SHX Text
FENCE
AutoCAD SHX Text
POWER ELECTRIC UNDERGROUND
AutoCAD SHX Text
COMMUNICATIONS LINE UNDERGROUND
AutoCAD SHX Text
GAS UNDERGROUND
AutoCAD SHX Text
TREES
AutoCAD SHX Text
SANITARY SEWER MANHOLE (PROPOSED)
AutoCAD SHX Text
SANITARY SEWER 2-WAY CLEANOUT (PROPOSED)
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text W
AutoCAD SHX Text V
AutoCAD SHX Text W
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text C
AutoCAD SHX Text
LIMITS OF CONSTRUCTION/LIMITS OF DISTURBANCE
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
WATER VALVE
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
WATER MANHOLE
AutoCAD SHX Text
IRRIGATION CONTROL VALVE
AutoCAD SHX Text
ELECTRIC BOX
AutoCAD SHX Text
ELECTRIC METER
AutoCAD SHX Text
POWER POLE
AutoCAD SHX Text
PULLBOX
AutoCAD SHX Text
COMMUNICATIONS MANHOLE
AutoCAD SHX Text
BOLLARD
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
UNDERGROUND UTILITY (UNKNOWN)
AutoCAD SHX Text
SANITARY SEWER UNDERGROUND (EXISTING)
AutoCAD SHX Text
SANITARY SEWER UNDERGROUND (PROPOSED)
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
C
IV
IL
D
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
AC
02 3
G
EN
ER
AL
N O
TE
S
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\G-003 GENERAL NOTES.dwg
AutoCAD SHX Text
5/15/2025 11:28 AM
AutoCAD SHX Text
%%UGENERAL CONSTRUCTION NOTES
AutoCAD SHX Text
1) UNLESS SPECIFIED OTHERWISE, ALL CONSTRUCTION AND MATERIALS SHALL BE IN UNLESS SPECIFIED OTHERWISE, ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE MOST RECENT VERSION OF THE CITY OF OKLAHOMA CITY STANDARD SPECIFICATIONS FOR CONSTRUCTION OF PUBLIC IMPROVEMENTS AND SHALL BE UNDER THE SUPERVISION OF THE CITY ENGINEER OF OKLAHOMA CITY OR HIS REPRESENTATIVE. 2) CONSTRUCTION STANDARDS SHALL BE IN ACCORDANCE WITH CITY OF OKLAHOMA CITY CONSTRUCTION STANDARDS SHALL BE IN ACCORDANCE WITH CITY OF OKLAHOMA CITY STANDARDS AND DEPARTMENT OF ENVIRONMENTAL QUALITY REGULATIONS AND TINKER AIR FORCE BASE. 3) THE BIDDER SHALL EXAMINE CAREFULLY THE SITE OF THE PROPOSED WORK TO BE THE BIDDER SHALL EXAMINE CAREFULLY THE SITE OF THE PROPOSED WORK TO BE SATISFIED AS TO THE CHARACTER AND QUANTITY OF WORK TO BE PERFORMED. 4) THE CONTRACTOR SHALL TAKE ACTIONS TO BE SATISFIED AS TO THE ACCURACY OF ALL THE CONTRACTOR SHALL TAKE ACTIONS TO BE SATISFIED AS TO THE ACCURACY OF ALL MEASUREMENTS PRIOR TO CONSTRUCTION. 5) ALL WORK AND/OR MATERIALS THAT DO NOT HAVE A PAY ITEM WILL BE CONSIDERED ALL WORK AND/OR MATERIALS THAT DO NOT HAVE A PAY ITEM WILL BE CONSIDERED INCIDENTAL WITH THE COST INCLUDED IN OTHER ITEMS. NO ADDITIONAL COMPENSATION WILL BE PROVIDED. ANY REFERENCE TO PAY ITEMS, BID ITEMS, BASIS OF PAYMENT AND PAYMENT METHODS IN STANDARD DRAWINGS DO NOT APPLY. 6) THE CONTRACTOR IS REQUIRED TO COMPLY WITH THE REQUIREMENTS OUTLINED IN THE THE CONTRACTOR IS REQUIRED TO COMPLY WITH THE REQUIREMENTS OUTLINED IN THE OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY (ODEQ) GENERAL PERMIT FOR STORM WATER DISCHARGES FROM CONSTRUCTION ACTIVITIES (OKR10). IN BRIEF, THE CONTRACTOR IS REQUIRED TO SUBMIT TINKER AFB’S NOTICE OF INTENT (NOI) FORM TO S NOTICE OF INTENT (NOI) FORM TO THE TAFB STORM WATER PROGRAM MANAGEMENT OFFICE REQUESTING FOR THE AUTHORIZATION TO DISCHARGE POLLUTANTS FOR THE CONSTRUCTION ACTIVITY. THE DEVELOPMENT AND IMPLEMENTATION OF A STORM WATER POLLUTION PREVENTION PLAN IS REQUIRED AND MUST BE SUBMITTED WITH THE NOI. THIS PLAN SHALL PROVIDE FOR THE CONTROL OF STORM WATER RUNOFF FROM CONSTRUCTION ACTIVITIES TO REDUCE STORM WATER CONTAMINATION. THE NOI AND SWPPP MUST BE SUBMITTED AND AUTHORIZED PRIOR TO DISCHARGING ANY POLLUTANTS. THE TAFB ENVIRONMENTAL OFFICE CAN BE CONTACTED AT (405) 734-1228 TO OBTAIN FURTHER INFORMATION. 7) FOR PROJECTS DISTURBING OVER AN ACRE OF LAND, THE CONTRACTOR IS REQUIRED TO FOR PROJECTS DISTURBING OVER AN ACRE OF LAND, THE CONTRACTOR IS REQUIRED TO SUBMIT TO THE ODEQ DEQ FORM 605-002A, NOTICE OF INTENT FOR STORM WATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY ON SITES OF ONE ACRE OR MORE ACRES. THE CONTRACTOR MUST PROVIDE A COPY OF THE CERTIFICATION AUTHORIZING THE DISCHARGE FROM THE ODEQ TO THE TAFB STORM WATER PROGRAM MANAGEMENT OFFICE BEFORE ANY CONSIDERATION WILL BE GIVEN FOR AUTHORIZATION FOR THE TAFB NOI. 8) THE COST OF DEVELOPING A STORM WATER POLLUTION PREVENTION PLAN, OBTAINING A THE COST OF DEVELOPING A STORM WATER POLLUTION PREVENTION PLAN, OBTAINING A STORM WATER DISCHARGE PERMIT AND ANY OTHER STATE OR FEDERAL LAND OR WATER DISTURBING PERMITS SHALL BE INCLUDED IN THE BID ITEM EROSION AND SEDIMENT CONTROL. A STORM WATER DISCHARGE PERMIT IS REQUIRED BEFORE ANY LAND DISTURBING ACTIVITIES CAN BEGIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTIVITIES CAN BEGIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND REPLACEMENT OF ALL EROSION CONTROL MEASURES REQUIRED TO OBTAIN THE PERMITS. 9) CONTRACTOR SHALL CONSTRUCT SILT FENCES, SILT DIKES, OR OTHER PHYSICAL BARRIERS CONTRACTOR SHALL CONSTRUCT SILT FENCES, SILT DIKES, OR OTHER PHYSICAL BARRIERS AS NECESSARY AROUND DISTURBED AREAS TO CONTROL EROSION, OFF-SITE SILTATION, AND COMPLY WITH APPLICABLE ENVIRONMENTAL LAWS AND REGULATIONS. 10) IF AN EROSION CONTROL PLAN IS REQUIRED BY THE PERMITTING PROCESS, THE IF AN EROSION CONTROL PLAN IS REQUIRED BY THE PERMITTING PROCESS, THE CONTRACTOR SHALL PREPARE A PLAN AND A COPY OF THE EROSION CONTROL PLAN MUST BE ON SITE AT ALL TIMES AND MADE AVAILABLE TO THE INSPECTOR UPON REQUEST. 11) CONTRACTOR IS TO KEEP STREETS CLEAN OF ALL CONSTRUCTION RELATED MATERIAL AT CONTRACTOR IS TO KEEP STREETS CLEAN OF ALL CONSTRUCTION RELATED MATERIAL AT ALL TIMES. CLEAN UP STREETS SHALL BE DONE AS NEEDED TO MAINTAIN CLEAN STREETS. 12) THE CONTRACTOR MAY REQUEST SUBSTITUTION OF ALTERNATE METHODS OF CONSTRUCTION THE CONTRACTOR MAY REQUEST SUBSTITUTION OF ALTERNATE METHODS OF CONSTRUCTION FROM THAT CALLED FOR, SUBJECT TO APPROVAL BY THE ENGINEER. THE CONTRACTOR SHALL THEN BE PAID THE LESSER OF THE SUM OF THE ASSOCIATED BID ITEMS FOR THE RESPECTIVE METHODS. 13) COORDINATES SPECIFIED FOR STRUCTURES ARE APPROXIMATE AND SHALL BE VERIFIED BY COORDINATES SPECIFIED FOR STRUCTURES ARE APPROXIMATE AND SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION OF THE STRUCTURES. 14) THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GPS "AS-BUILT" SURVEY, FOLLOWING THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GPS "AS-BUILT" SURVEY, FOLLOWING THE COMPLETION OF CONSTRUCTION, FOR EVERY 100 FEET ALONG THE ALIGNMENT OF THE PROJECT. LOCATION OF MANHOLES, RIM ELEVATIONS, INVERTS, CASINGS, VALVES, METERS, PUMPS, AND SIMILAR APPURTENANCES SHALL BE LOCATED. AN AUTOCAD DRAWING AND COORDINATE DATA SHEET INCLUDING POINT DESCRIPTIONS, FLOW LINES AND COORDINATES DATA SHALL BE SUBMITTED TO THE PROJECT ENGINEER FOR APPROVAL THIS TASK MUST BE PERFORMED BY A REGISTERED PROFESSIONAL LAND SURVEYOR. ALL DRAWINGS MUST BE SIGNED AND CERTIFIED BY A REGISTERED PROFESSIONAL LAND SURVEYOR. DATA SUBMITTED SHALL BE TIED TO THE OKLAHOMA STATE PLANE COORDINATE SYSTEM. 15) SERVICE CONNECTIONS ARE APPROXIMATE AND SHALL BE FIELD ADJUSTED BY THE SERVICE CONNECTIONS ARE APPROXIMATE AND SHALL BE FIELD ADJUSTED BY THE CONTRACTOR BASED ON LOCATION OF EXISTING SERVICE LINES. SERVICE CONNECTIONS MUST BE MEASURED TO DETERMINE THE FOOTAGE FROM THE NEAREST DOWNSTREAM MANHOLE OR GPS COORDINATES (IF PROVIDED). THESE MEASUREMENTS OR GPS DATA SHALL BE PROVIDED TO THE INSPECTOR FOR AS-BUILT INFORMATION. SERVICE LINE CONNECTIONS WILL ALSO NEED TO BE INCLUDED ON THE AS-BUILT PLANS. 16) CONTRACTOR IS RESPONSIBLE FOR NECESSARY SHEETING AND SHORING TO KEEP THE CONTRACTOR IS RESPONSIBLE FOR NECESSARY SHEETING AND SHORING TO KEEP THE TRENCH SIDE VERTICAL WHERE THE EXCAVATION SLOPE WOULD DAMAGE IMPROVEMENTS AND AS REQUIRED BY OSHA. THE CONTRACTOR SHALL EXERCISE ALL PRECAUTIONS AND TAKE NECESSARY STEPS TO PROTECT EXISTING STRUCTURES, IMPROVEMENTS, SIDEWALKS, PAVEMENT, FENCES, LANDSCAPING, ETC. ANY DAMAGE TO EXISTING ITEMS TO REMAIN SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE. COST OF SHEET PILING OR TRENCH BRACING TO BE INCLUDED IN OTHER ITEMS OF WORK. 17) THE CONTRACTOR SHALL KEEP ANY OPEN TRENCH DRAINED. COST TO BE INCLUDED IN THE CONTRACTOR SHALL KEEP ANY OPEN TRENCH DRAINED. COST TO BE INCLUDED IN OTHER ITEMS OF WORK. 18) CONTRACTOR SHALL PROVIDE ACCESS TO ALL PROPERTY AT ALL TIMES. CONTRACTOR SHALL PROVIDE ACCESS TO ALL PROPERTY AT ALL TIMES. 19) CONTRACTORS SHALL BE REQUIRED TO OBTAIN AN APPROVED DIG PERMIT PRIOR TO CONTRACTORS SHALL BE REQUIRED TO OBTAIN AN APPROVED DIG PERMIT PRIOR TO COMMENCING CONSTRUCTION. THIS PERMIT MAY REQUIRE UP TO 21 DAYS TO PROCESS AND THE CONTRACTOR SHOULD PLAN ACCORDINGLY. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION INSPECTOR FIVE (5) BUSINESS DAYS PRIOR TO COMMENCING WORK ON A PROJECT SITE. AFTER A WORK DELAY EXCEEDING TWENTY-FOUR HOURS, THE CONSTRUCTION INSPECTOR SHALL BE NOTIFIED ONE (1) BUSINESS DAY PRIOR TO RESUMING WORK ON A PROJECT SITE. FAILURE OF THE CONTRACTOR TO COMPLY WITH THESE REQUIREMENTS MAY RESULT IN REMOVAL OF WORK COMPLETED PRIOR TO MAKING THE PROPER NOTIFICATIONS, IN ORDER TO PERFORM REQUIRED INSPECTIONS, AT NO ADDITIONAL COST TO THE CITY. 20) CLOSURES OF PAVED AREAS (E.G. ROADS, LANES, PARKING) OR FACILITIES OR PORTIONS CLOSURES OF PAVED AREAS (E.G. ROADS, LANES, PARKING) OR FACILITIES OR PORTIONS OF FACILITIES (E.G. DOORWAYS, AISLES, RESTROOMS) FREQUENTLY AFFECT MORE THAN ONE FACILITY OR ORGANIZATION AND REQUIRE EXTENSIVE COORDINATION. FOR THIS REASON, THE CONTRACTOR SHALL SUBMIT ALL REQUESTS FOR CLOSURES, IN WRITING, TO THE TAFB A MINIMUM OF 45 DAYS IN ADVANCE OF THE PROPOSED CLOSURE. 21) THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF ALL PAVEMENT MARKINGS THAT THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF ALL PAVEMENT MARKINGS THAT WILL BE IN CONFLICT WITH THE PROPOSED WORK. 22) THE CONTRACTOR SHALL MAINTAIN ACCESS ON ALL STREETS AND TO FACILITIES DURING THE CONTRACTOR SHALL MAINTAIN ACCESS ON ALL STREETS AND TO FACILITIES DURING REGULAR BUSINESS HOURS FOR EACH ESTABLISHMENT. 23) TRENCHING OPERATION ACROSS DRIVEWAYS AND MINOR ROADWAYS SHALL BE TRENCHING OPERATION ACROSS DRIVEWAYS AND MINOR ROADWAYS SHALL BE ACCOMPLISHED 1/2 WIDTH AT A TIME WHENEVER POSSIBLE SO THAT NO ROADWAY IS COMPLETELY CLOSED UNLESS APPROVED BY TAFB. 24) ANY DAMAGE TO A FINISHED OR EXISTING SURFACE TO REMAIN, RESULTING FROM ANY DAMAGE TO A FINISHED OR EXISTING SURFACE TO REMAIN, RESULTING FROM CONSTRUCTION ZONE PAVEMENT MARKERS OR TUBE CHANNELIZERS AND THE ADHESIVE USED IN THEIR INSTALLATION, SHALL BE REPAIRED AT THE CONTRACTORS EXPENSE AND TO THE SATISFACTION OF THE ENGINEER. 25) ALL P.C. CONCRETE PAVEMENT, CURBS, DRIVEWAYS, AND SIDEWALKS DISTURBED BY THIS ALL P.C. CONCRETE PAVEMENT, CURBS, DRIVEWAYS, AND SIDEWALKS DISTURBED BY THIS PROJECT SHALL BE REPLACED WITH HIGH EARLY STRENGTH (HES) CONCRETE, 4000 P.S.I. MIN. 26) THE CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING ALL DISTURBED AREAS TO DRAIN THE CONTRACTOR SHALL BE RESPONSIBLE FOR GRADING ALL DISTURBED AREAS TO DRAIN AS GOOD OR BETTER THAN EXISTING CONDITIONS. 27) THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL EROSION CONTROL REQUIRED UNTIL THE CONTRACTOR WILL BE RESPONSIBLE FOR ALL EROSION CONTROL REQUIRED UNTIL THE AREA IS ACCEPTED BY THE CONTRACTING OFFICER AS BEING RETURNED TO ITS ORIGINAL CONDITION. WHEN A TEMPORARY GROUND COVER IS NEEDED UNTIL WARM-SEASON GRASSES CAN BE ESTABLISHED, THE GROUND SHALL BE COVERED WITH AN APPROPRIATELY ANCHORED BIODEGRADABLE MATERIAL SUCH AS STRAW/NATIVE HAY MULCH, EROSION CONTROL BLANKETS, HYDROMULCH, OR SIMILAR MATERIAL. COOL-SEASON GRASSES AND CEREAL GRAINS, SUCH AS RYEGRASS AND WHEAT ARE NOT PERMITTED WITHOUT ADVANCE APPROVAL FROM THE BASE NATURAL RESOURCES FUNCTION AND CONTRACTING OFFICER. HOWEVER, PERMANENT NATIVE WARM-SEASON GRASSES SHALL BE ESTABLISHED PRIOR TO CONTRACT COMPLETION. ALL GRASSES MUST BE NATIVE AND COMPLY WITH THE TAFB INTEGRATED NATURAL RESOURCES MANAGEMENT PLAN, UNLESS WAIVED BY THE TAFB CONTRACTING OFFICER. 28) REMOVED MATERIAL TO BECOME PROPERTY OF CONTRACTOR AND IT SHALL BE DISPOSED REMOVED MATERIAL TO BECOME PROPERTY OF CONTRACTOR AND IT SHALL BE DISPOSED OF IN A MANNER APPROVED BY THE ENGINEER. 29) ALL PAVEMENT REMOVALS TO BE ON NEAT SAWED LINES. ALL PAVEMENT REMOVALS TO BE ON NEAT SAWED LINES. 30) THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, WHETHER THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, WHETHER PRIVATE OR PUBLIC PRIOR TO EXCAVATING. THE INFORMATION AND DATA SHOWN WITH RESPECT TO THE EXISTING UNDERGROUND FACILITIES AT OR ADJACENT TO THE SITE IS APPROXIMATED. THE OWNER AND ENGINEER SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF ANY SUCH INFORMATION OR DATA; AND THE CONTRACTOR SHALL HAVE FULL RESPONSIBILITY FOR REVIEWING AND CHECKING ALL INFORMATION OR DATA; FOR LOCATING ALL UNDERGROUND FACILITIES DURING CONSTRUCTION, FOR THE SAFETY AND PROTECTION THEREOF, AND REPAIRING ANY DAMAGE TO THERETO RESULTING FROM THE WORK, THE COST OF ALL WHICH WILL BE CONSIDERED AS HAVING BEEN INCLUDED IN OTHER ITEMS OF WORK. THE CONTRACTOR SHALL ASSUME THAT ADDITIONAL UNDERGROUND LINES DO EXIST AND ARE NOT SHOWN ON THESE DRAWINGS. CONTRACTOR SHALL NOTIFY ANY AFFECTED UTILITY COMPANIES OR AGENCIES AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION. BEFORE EXCAVATION CALL "OKIE" PIPE LINE LOCATORS AT (405) 840-5032 OR (800) 522-6543. EXISTING UTILITIES CONFLICTING WITH PROPOSED IMPROVEMENTS SHALL BE BROUGHT TO THE ENGINEER'S IMMEDIATE ATTENTION PRIOR TO BEGINNING CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING UTILITY COMPANIES PRIOR TO COMMENCING WORK. LIKEWISE, THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WORK AND THAT OF THE INVOLVED UTILITIES IN THE PROJECT AREA. THE CONTRACTOR SHALL ANCHOR POWER POLES IF NECESSARY DURING CONSTRUCTION. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR NECESSARY SHIELDING REQUIRED FOR OVERHEAD POWER LINES THAT MAY CROSS THE WORK AREA. COORDINATION OF THE POWER POLE'S ANCHOR AND SHIELDING REQUIREMENTS WILL BE THE CONTRACTOR'S RESPONSIBILITY. 31) ANY DAMAGE TO EXISTING UTILITIES OR IRRIGATION SYSTEMS SHALL BE REPAIRED BY THE ANY DAMAGE TO EXISTING UTILITIES OR IRRIGATION SYSTEMS SHALL BE REPAIRED BY THE CONTRACTOR AT HIS OWN EXPENSE. 32) THERE ARE SEVERAL LOCATIONS WHERE THE CONTRACTOR WILL HAVE TO PLACE THE THERE ARE SEVERAL LOCATIONS WHERE THE CONTRACTOR WILL HAVE TO PLACE THE SEWER NEXT TO AND UNDER EXISTING UTILITIES SUCH AS WATER SERVICE LINES, NATURAL GAS LINES, AND IRRIGATION SYSTEMS. THE COST OF HAND DIGGING AROUND THESE UTILITIES OR TREES AND PLACING THE SEWER SHALL BE INCLUDED IN THE PRICE BID OF OTHER ITEMS. 33) CONTRACTOR SHALL LOCATE THE DEPTH OF ALL UTILITIES WITHIN 10 FEET OF A UTILITY CONTRACTOR SHALL LOCATE THE DEPTH OF ALL UTILITIES WITHIN 10 FEET OF A UTILITY AND SANITARY SEWER CROSSING BEFORE THE EXCAVATION OF THE SANITARY SEWER TRENCH IS STARTED. THE CONTRACTOR SHALL DOCUMENT THE LOCATION AND DEPTH OF UTILITY CROSSINGS AND VERIFY THAT A 2 FOOT MINIMUM VERTICAL CLEARANCE IS AVAILABLE BETWEEN ANY WATER LINE. IF TWO FOOT OF VERTICAL CLEARANCE IS NOT AVAILABLE, CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY BEFORE STARTING INSTALLATION. 34) CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOR THE REMOVAL & DISPOSAL OF TRANSITE PIPE, IF ANY. 35) IF THE TELEVISION INSPECTION REVEALS A SAG IN THE SEWER LINE LARGER THAN IF THE TELEVISION INSPECTION REVEALS A SAG IN THE SEWER LINE LARGER THAN ONE-HALF THE DIAMETER OF THE PIPE, THEN POINT REPAIR THAT SECTION OF PIPE TO PROVIDE A UNIFORM GRADE. 36) WHEN INSTALLING SANITARY SEWER PIPE THROUGH A CASING, END SEALS SHALL BE USED WHEN INSTALLING SANITARY SEWER PIPE THROUGH A CASING, END SEALS SHALL BE USED AND SOIL TIGHT PLUGS SHALL BE PROVIDED AT NO COST, UNLESS NOTED ON THE PLANS SOIL TIGHT PLUGS SHALL BE PROVIDED AT NO COST, UNLESS NOTED ON THE PLANS AND PAY ITEMS. THE PLUGS SHALL BE CONSTRUCTED SO THAT NO SOIL INFILTRATION ITEMS. THE PLUGS SHALL BE CONSTRUCTED SO THAT NO SOIL INFILTRATION CAN OCCUR. PROPOSED PLUGGING PROCEDURE SHALL BE APPROVED BY THE ENGINEER OR INSPECTOR PRIOR TO INSTALLATION. 37) CONTRACTOR SHALL BACKFILL ALL EXCAVATION PITS AND/OR TRENCHES BEFORE LEAVING CONTRACTOR SHALL BACKFILL ALL EXCAVATION PITS AND/OR TRENCHES BEFORE LEAVING JOB SITE AND SHALL PLACE SAFETY FENCES AROUND EXCAVATION AREAS AS NEEDED DURING CONSTRUCTION TO PROTECT ALL PERSONNEL IN THE AREA. 38) THE CONTRACTOR SHALL BE RESPONSIBLE FOR MANAGING ALL SANITARY SEWER FLOW THE CONTRACTOR SHALL BE RESPONSIBLE FOR MANAGING ALL SANITARY SEWER FLOW AND SEWER LINE SERVICES AND WATER LINE SERVICES DURING CONSTRUCTION IN A MANNER APPROVED BY THE CITY OF OKLAHOMA CITY, AND ALL COSTS SHALL BE INCIDENTAL. COST OF ANY TEMPORARY PIPE, PUMPING, CONNECTIONS, OR COVERING/PLUGGING OF PIPE FOR BYPASSING EXISTING SEWER FLOW FROM CONSTRUCTION AREAS AS NEEDED FOR CONSTRUCTION PHASING TO BE INCLUDED IN PRICE BID. 39) THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROMPT REPLACEMENT AND/OR THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROMPT REPLACEMENT AND/OR REPAIR OF ALL EXISTING ADA IMPROVEMENTS DAMAGED OR DISTURBED DURING CONSTRUCTION. 40) FUSION BONDED SADDLES ARE REQUIRED ON ALL SERVICES ON NEW HDPE/PVC PIPE FUSION BONDED SADDLES ARE REQUIRED ON ALL SERVICES ON NEW HDPE/PVC PIPE USED FOR TRENCHLESS CONSTRUCTION. WYE FITTINGS CONNECTIONS ARE REQUIRED ON ALL OPEN CUT SERVICES. 41) ALL MANHOLES THAT ARE TO BE REPLACED IN PAVED AREAS SHALL HAVE NON-VENTED ALL MANHOLES THAT ARE TO BE REPLACED IN PAVED AREAS SHALL HAVE NON-VENTED LIDS WITH RAINGUARD INFLOW PROTECTORS. ALL COSTS TO BE INCLUDED IN PRICE BID FOR SANITARY SEWER MANHOLES. 42) ANY MANHOLES THAT ARE REPLACED ARE TO BE BUILT TO AN ELEVATION NOT LESS THAN ANY MANHOLES THAT ARE REPLACED ARE TO BE BUILT TO AN ELEVATION NOT LESS THAN THAT OF THE EXISTING GROUND SURFACE, OR AS SHOWN ON THE DRAWINGS. MANHOLES TO BE FLUSH WITH PAVEMENT IN PAVED AREAS. 43) CONTRACTOR SHALL CLEAN OUT ANY MANHOLE INVERT BEFORE INSPECTOR OR ENGINEER CONTRACTOR SHALL CLEAN OUT ANY MANHOLE INVERT BEFORE INSPECTOR OR ENGINEER APPROVES INVERT AND BENCH RECONSTRUCTION. ALL COSTS OF CLEANING BENCH AND INVERT TO BE INCLUDED IN OTHER ITEMS OF WORK. 44) COMPACTION OF TRENCH BACKFILL SHALL BE 95% STANDARD PROCTOR DENSITY. COMPACTION OF TRENCH BACKFILL SHALL BE 95% STANDARD PROCTOR DENSITY. 45) THE CONTRACTOR SHALL INSTALL ALL SANITARY SEWERS AND SEWER APPURTENANCES IN THE CONTRACTOR SHALL INSTALL ALL SANITARY SEWERS AND SEWER APPURTENANCES IN ACCORDANCE WITH SECTION 600 OF THE OKC STANDARD SPECIFICATIONS FOR THE CONSTRUCTION OF PUBLIC IMPROVEMENTS. 46) PROPOSED CLEANOUTS SHALL BE BI-DIRECTIONAL AND INSTALLED WITHIN 10 FEET PROPOSED CLEANOUTS SHALL BE BI-DIRECTIONAL AND INSTALLED WITHIN 10 FEET MAXIMUM OF THE BUILDING FOUNDATION.
AutoCAD SHX Text
%%UGENERAL CONSTRUCTION NOTES CONTINUED...
%%UGENERAL CONSTRUCTION NOTES CONTINUED...
SH
T C0
SH
EE
T C0
SHEET C006
SHEET C007
TINKER AFB
ARNOLD ST
AI
R
D
EP
O T
BL
VD
VANDENBERG ST
M
ITCHELL AVE
RAWLINGS AVE
RESERVE RD
AI
R
D
EP
O T
BL
VD
M
ITC
H
ELL AVE
TWINING DR
COOK AVE
M cN
AR
N
EY
A
VE
TINKER GOLF COURSE
70037016 7005 1014
70387041
7028C
C R
U
TC
H O
C R
EE
K
NEW MH
A1
NEW MH
A2
NEW MH
A3
NEW MH
A4
ROUTE A - NEW 8"
PVC SEWER
ESTIMATED EXISTING SERVICE
CONNECTIONS TO REMAIN IN
PLACE
NEW MH B1
ROUTE B - NEW 8"
PVC SEWER
NEW MH B3
NEW MH B5
LIFT STATION #7038
TO BE ABANDONED
NEW MH C1
NEW CO
LIFT STATION #7043
TO BE ABANDONED
ABANDONED EX SERVICE
CONNECTION
ROUTE C - NEW
8" PVC SEWER
CONNECT TO
EX SMHP-772
LOCATION OF
SITE 2 ROUTE B
RESERVE ROAD
LOCATION OF
SITE 3 ROUTE C
LIFT STATION #7007
TO BE ABANDONED
CP 190
LIFT STATION #6642
TO BE ABANDONED
NEW MH B4
NEW MH C2
EXISTING SOUTH SANITARY
CREEK CROSSING
ABANDONED EXISTING
PIPE FROM EX
SMHP-836 TO EXISTING
SERVICE CONNECTION
EXISTING AERIAL SEWER LINE
CREEK CROSSING TO BE REMOVED
FROM SMPH-833 TO SMPH-836
(SEE DETAIL A5, SHEET C500)
LOCATION OF
SITE 1 ROUTE A
SHEET C002
NEW CO
NEW CO
NEW CO
NEW CO
NEW MH B2
R
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
C
IV
IL
D
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
400'0 200'
NORTH
SCALE: 1" = 200'
LOCATION MAP1
C
SI
TE
S O
VE
RV
IE
W
A
ND
LO
CA
TI
O
N M
AP
PROPOSED
EXISTING
TO BE REMOVED/ABANDONED
LEGEND
SURVEY CONTROL
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\1400390-LOCATION PLAN.dwg
AutoCAD SHX Text
3/7/2025 1:24 PM
AutoCAD SHX Text
POINT#
AutoCAD SHX Text
NORTHING
AutoCAD SHX Text
EASTING
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
HORIZONTAL DATUM: STATE PLANE, NAD83, OKLAHOMA NORTH
AutoCAD SHX Text
VERTICAL DATUM: NAVD88
AutoCAD SHX Text
OFF SITE HORIZONTAL AND VERTICAL CONTROL
AutoCAD SHX Text 157287.72
AutoCAD SHX Text 2149147.83
AutoCAD SHX Text 1245.21
AutoCAD SHX Text
#4 BAR W/ "LEMKE" CAP
AutoCAD SHX Text
CP 188
AutoCAD SHX Text 156550.02
AutoCAD SHX Text 2142993.82
AutoCAD SHX Text 1211.98
AutoCAD SHX Text
#4 BAR W/ "LEMKE" CAP
CP 190
CR
UT
CH
O
C
RE
EK
(UIP)
(U
IP
(TBA)
(UIP)
(TBR)
(TBA)
(TBA)
(UIP)
(UIP)
(UIP)
(UIP)
(UIP)
(UIP)
(TBA)
(UIP)
(TBA)
ARNOLD STREET
(UIP)
REMOVE APPROXIMATELY 100' OF
EXISTING AERIAL SANITARY CREEK
CROSSING AND CONCRETE SUPPORT
PEDESTALS (SEE DETAIL A5, SHEET C500)
M
IT
C H
EL
L
AV
E
M
IT
CH
EL
L
AV
E
(TBA)
40' 80'0
NORTH
C
DE
M
O
LI
TI
O
N
PL
AN
SI
TE
RO
UT
E
A
SCALE: 1" = 40'
DEMOLITION PLAN - SITE 1 ROUTE A1
ABBREVIATIONS
TBA = TO BE ABANDONED IN-PLACE
TBR = TO BE REMOVED
UIP = USE IN PLACE
VCP = VITRIFIED CLAY PIPE
PHOTO 3 - EXISTING SANITARY CREEK
CROSSING SOUTH OF ARNOLD STREET BRIDGE
PHOTO 4 - EXISTING SANITARY CREEK
CROSSING SOUTH OF ARNOLD STREET BRIDGE
SOUTH SANITARY CREEK CROSSING NOTE:
CONTRACTOR SHALL PROVIDE A GENERAL CLEAN-UP OF THE STREAM BED FROM THE
CENTERLINE OF THE SEWER NORTH TO THE CENTER LINE OF THE ARNOLD STREET
BRIDGE AND SOUTH FOR THE SAME DISTANCE. THE CLEAN-UP SHALL INCLUDE THE
REMOVAL OF TRASH, GARBAGE, AND SCRAP MATERIALS FROM THE STREAM BANK OF
CRUTCHO CREEK. LIVE TREES AND BRUSH SHALL REMAIN IN-PLACE WHILST LOOSE
LIMBS AND LOOSE BRUSH ARE TO BE REMOVED. CLEAN-UP PROCEDURES AND
METHODS MUST BE SUBMITTED AS A SHOP DRAWING AND APPROVED BY THE
ENGINEER AND TAFB NATURAL RESOURCE (405 836-2941).
PHOTO 1 - EXISTING SANITARY CREEK
CROSSING NORTH OF ARNOLD STREET BRIDGE
PHOTO 2 - EXISTING SANITARY CREEK
CROSSING NORTH OF ARNOLD STREET BRIDGE
NORTH SANITARY CREEK CROSSING NOTE:
THE STREAM BED NORTH OF THE BRIDGE SHALL BE CLEANED AFTER
REMOVAL OF THE ELEVATED SEWER LINE FOR A DISTANCE OF 50-FEET
NORTH OF THE CENTERLINE OF THE ARNOLD STREET BRIDGE.
REMOVAL AND CLEARING IN CREEK PROCEDURES AND METHODS
MUST BE SUBMITTED AS A SHOP DRAWING AND APPROVED BY THE
ENGINEER AND TAFB NATURAL RESOURCE (405 736-2941).
R
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
C
IV
IL
D
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
AutoCAD SHX Text COULD NOT VERIFY EXACT LOCATION OF CONNECTION TO SANITARY SYSTEM, APPROXIMATE AND ASSUMED LOCATION SHOWN WITH SS|A| LINETYPE
AutoCAD SHX Text
ASPHALT CART PATH
AutoCAD SHX Text
CLEANOUT COULD NOT OPEN
AutoCAD SHX Text
CLEANOUT LID:1217.76 FL:1216.78
AutoCAD SHX Text
CLEANOUT LID:1218.21 FL:1215.12
AutoCAD SHX Text SMHP-833 RIM:1201.67 SE 8" VCP FL:1191.36 FL:1191.36 1191.36 NE 8" VCP FL:1191.54FL:1191.541191.54
AutoCAD SHX Text SMHP-836 RIM:1204.21 SW 8" VCP FL:1194.23 FL:1194.23 1194.23 NE 6" VCP FL:1194.30FL:1194.301194.30
AutoCAD SHX Text SMHP-781 RIM:1201.68 N 36" PVC FL:1187.53 FL:1187.53 1187.53 SW 36" PVC FL:1187.68 FL:1187.68 1187.68 SE 24" PVC FL:1189.75FL:1189.751189.75
AutoCAD SHX Text
SMHP-772 RIM:1210.63 WNW 24" PVC FL:1193.80 SW 24" PVC FL:1193.80
AutoCAD SHX Text
SPUP-107 RIM:1209.21
AutoCAD SHX Text SMHP-1170 RIM:1212.43 SW 6" VCP FL:1208.91 FL:1208.91 1208.91 NE 6" VCP FL:1208.94 FL:1208.94 1208.94 NNE 8" VCP FL:1212.43FL:1212.431212.43
AutoCAD SHX Text
GAS PIPELINE MARKERS
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\1400390-DEMOLITION PLANS.dwg
5/15/2025 3:24 PM
RESERVE RD
7028C
(UIP)
(UIP)
(UIP)
(UIP)
(TBA)
(UIP)
(TBA)
(UIP)
(UIP)
(UIP)
(UIP)
(UIP)(UIP)
(UIP)
(U
IP
) (UIP)
(U
IP)
(U
IP)
(UIP)
(U
IP
(U
IP
(UIP)
(UIP)
(UIP)
(UIP)
(UIP)
NOTE: THE EXISTING SANITARY SEWER
SHOWN IS FROM THE DATA COLLECTED IN
THE PRELIMINARY SURVEY. THE GIS UTILITY
INFORMATION IS NOT SHOWN FOR CLARITY.
EXISTING LIFT STATION #7043
TO BE ABANDONED
ABANDONMENT OF LIFT STATIONS WILL CONSIST OF
A) REMOVING THE PUMP BASIN AND ALL PUMPS, MOTORS, COUPLINGS, VALVES, CONTROL
PANELS, INSTRUMENTATION, ELECTRICAL SERVICE, AND ALL APPURTENANCES ABOVE
FINISHED GRADE; AND
B) CUTTING DOWN UNNEEDED FACILITIES TO FOUR FEET BELOW GRADING, FILLING WITH
CEMENT STABILIZED SAND, AND COVERING WITH HARD PAVEMENT TO MATCH EXISTING
GRADE. WHERE LIFT STATIONS ARE LOCATED IN SIDEWALKS, THE EXCAVATION WILL BE
FILLED WITH TYPE A AGGREGATE AND THE SIDEWALK REPAIRED WITH CONCRETE IN
LIKE NEW OR BETTER CONDITION. ELECTRICAL AND CONTROL WIRING WILL BE
REMOVED BACK TO SOURCE AND CONDUIT WILL BE CUT UNDERGROUND AND
ABANDONED IN-PLACE. ANY EXISTING ASSOCIATED FORCE MAIN THAT WILL NO LONGER
BE UTILIZED WILL BE PROPERLY BULKHEAD CAPPED AND ABANDONED.
RESERVE RD
AI
R
D
EP
O T
BL
VD
40' 80'0
NORTH
SCALE: 1" = 40'
DEMOLITION PLAN - SITE 3 ROUTE C1
C
DE
M
O
LI
TI
O
N
PL
AN
SI
TE
RO
UT
E
C
ABBREVIATIONS
TBA = TO BE ABANDONED
TBR = TO BE REMOVED
UIP = USE IN PLACE
VCP = VITRIFIED CLAY PIPE
R
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
C
IV
IL
D
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
AutoCAD SHX Text
SOLAR PANEL
AutoCAD SHX Text SMHP-1414 RIM:1230.10 NNE 12" PVC FL:1210.78 SSW 12" PVC FL:1210.83 NNE 6" MTL FL:1223.70 NE 4" PVC FL:1223.72 NW 4" PVC FL:1223.92
AutoCAD SHX Text SMHP-531 RIM:1230.08 NNE 12" PVC FL:1211.89 SSW 12" PVC FL:1211.93 W 6" PVC FL:1226.64
AutoCAD SHX Text SMHP-1387 RIM:1229.73 S 4" PVC FL:1223.27 SW 6" PVC FL:1219.82 E 8" PVC FL:1219.69 NW 12" PVC FL:1212.60
AutoCAD SHX Text
SMHP-1385 RIM:1229.23 NW 8" PVC FL:1220.93 NE 8" PVC FL:1220.93
AutoCAD SHX Text
SMHP-515 RIM:1231.28 NW 8" PVC FL:1222.28 NE 8" PVC FL:1222.38
AutoCAD SHX Text SMHP-522 RIM:1229.92 SW 8" PVC FL:1221.57 SE 8" PVC FL:1221.63 NE 2" PVC FL:1227.75
AutoCAD SHX Text
SMHP-524 RIM:1228.93 W 8" PVC:1220.53 SE 8" PVC:1220.59
AutoCAD SHX Text
LIFT STATION RIM:1231.43 2" PVC SOUTH TOP OF PIPE:1230.89 BOTTOM:1229.56
AutoCAD SHX Text
SMHP-1384 RIM:1231.07 SW 8" PVC FL:1222.33 SE 8" PVC FL:1222.33
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\1400390-DEMOLITION PLANS.dwg
5/15/2025 3:24 PM
SS
SS
SS
SS
SS
SS
S
SS
SS
SS
A3
STA 7+46.32
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156667.38
EASTING: 2143522.23
RIM: 1216.63
DEPTH: 13.38
N FL IN: PROP 8" PVC 1203.33
SW FL OUT: PROP 8" C900 DR-18 PVC 1203.25
A2
STA 4+25.38
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156542.52
EASTING: 2143226.58
RIM: 1213.80
DEPTH: 12.28
NE FL IN: PROP 8" C900 DR-18 PVC 1201.65
S FL OUT: PROP 8" PVC 1201.52
ABANDONED EXISTING
PIPE FROM EXISTING
SMHP-836 TO NEW
MANHOLE A2
SSSSSSSS
S
S
A4
STA 11+31.54
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 157052.54
EASTING: 2143529.58
RIM: 1215.89
DEPTH: 10.65
S FL OUT: PROP 8" PVC 1205.24
S FL IN: 8 '' PVC PIPE 1205.24
A1
STA 2+30.61
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156361.05
EASTING: 2143297.33
RIM: 1216.40
DEPTH: 15.90
N FL IN: PROP 8" PVC 1200.55
SW FL OUT: PROP 8" PVC 1200.50
PAVEMENT
REPLACEMENT
19 SY
160 OPEN TRENCH AND
220' - BORING FOR THIS
SECTION OF PIPE
(A3 TO A4)
ROUTE A
STA 0+00.00
INSTALL A
BATTERY-POWERED ADA
TRITON+ FLOW METER WITH
A PEAK COMO (CS4), AND
SURFACE COMBO (CS5-V).
MOUNT THE FLOW METER
TO THE MANHOLE RIM WITH
MONITOR BRACKET/FLANGE
(P/N 140-0009)
PAVEMENT
REPLACEMENT
4 SY
PAVEMENT
REPLACEMENT
1 SY
CONSTRUCTION
LIMITS
10'x10'
BORE PIT
20'x10'
BORE PIT
PAVEMENT
REPLACEMENT
1 SY
SS
SS
SS
SS
SS
SS
SS
STA 11+26.54
4" WYE CONNECTION
TO 8" PVC MAIN
STA 10+17.87
END BORING
STA 7+97.87
BEGIN BORING
STA 4+18.26
END BORING
UNDER STREET
STA 3+40.26
BEGIN BORING
UNDER STREET
STA 6+46.88
STA 6+54.07
CONNECT EXISTING LATERALS
TO PR 8" PVC MAIN
30' CO
NSTRUCTIO
N
LIM
ITS
(TYP.)
10'
10'
20' 10'
5' 25'
30' CONST. LIMITS
(TYP.) 10
10' 20'
S
SS
SS
SS
SS
SS
SS
S
SS
SS
SS
A3
STA 7+46.32
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156667.38
EASTING: 2143522.23
RIM: 1216.63
DEPTH: 13.38
N FL IN: PROP 8" PVC 1203.33
SW FL OUT: PROP 8" C900 DR-18 PVC 1203.25
A2
STA 4+25.38
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156542.52
EASTING: 2143226.58
RIM: 1213.80
DEPTH: 12.28
NE FL IN: PROP 8" C900 DR-18 PVC 1201.65
S FL OUT: PROP 8" PVC 1201.52
ABANDONED EXISTING
PIPE FROM EXISTING
SMHP-836 TO NEW
MANHOLE A2
SSSSSSSS
S
S
A4
STA 11+31.54
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 157052.54
EASTING: 2143529.58
RIM: 1215.89
DEPTH: 10.65
S FL OUT: PROP 8" PVC 1205.24
S FL IN: 8 '' PVC PIPE 1205.24
A1
STA 2+30.61
PROPOSED SANITARY SEWER MANHOLE (48")
NORTHING: 156361.05
EASTING: 2143297.33
RIM: 1216.40
DEPTH: 15.90
N FL IN: PROP 8" PVC 1200.55
SW FL OUT: PROP 8" PVC 1200.50
PAVEMENT
REPLACEMENT
19 SY
160 OPEN TRENCH AND
220' - BORING FOR THIS
SECTION OF PIPE
(A3 TO A4)
ROUTE A
STA 0+00.00
INSTALL A
BATTERY-POWERED ADA
TRITON+ FLOW METER WITH
A PEAK COMO (CS4), AND
SURFACE COMBO (CS5-V).
MOUNT THE FLOW METER
TO THE MANHOLE RIM WITH
MONITOR BRACKET/FLANGE
(P/N 140-0009)
PAVEMENT
REPLACEMENT
4 SY
PAVEMENT
REPLACEMENT
1 SY
CONSTRUCTION
LIMITS
10'x10'
BORE PIT
20'x10'
BORE PIT
PAVEMENT
REPLACEMENT
1 SY
SS
SS
SS
SS
SS
SS
SS
STA 11+26.54
4" WYE CONNECTION
TO 8" PVC MAIN
STA 10+17.87
END BORING
STA 7+97.87
BEGIN BORING
STA 4+18.26
END BORING
UNDER STREET
STA 3+40.26
BEGIN BORING
UNDER STREET
STA 6+46.88
STA 6+54.07
CONNECT EXISTING LATERALS
TO PR 8" PVC MAIN
NOTE:
ALL EXISTING TREES SHALL BE PROTECTED
DURING CONSTRUCTION.
ANY CONSTRUCTION WITHIN THE CANOPY OF
TREES REQUIRES A TREE ROOT PROTECTION
PLAN PER TAFB SPECS.
' C
ONSTR
UCTIO
N LI
MITS
20' CO
NSTRUCTIO
N LIM
ITS
ALL DAMAGED ROAD, CURB, & GUTTER
TO BE RESTORED IN SAME OR BETTER
CONDITION AT CONTRACTORS EXPENSE
5' 15'
-0+40 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+40
A2 STA 4+25.38
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1213.80
DEPTH: 12.28
NE FL IN: PROP 8" C900 DR-18 PVC 1201.65
S FL OUT: PROP 8" PVC 1201.52
A3 STA 7+46.32
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1216.63
DEPTH: 13.38
N FL IN: PROP 8" PVC 1203.33
SW FL OUT: PROP 8" C900 DR-18 PVC 1203.25
INSTALL 321 LF OF 8 INCH
C900 DR-18 PVC
SANITARY SEWER
(SEE NOTE 1)
EXISTING
GRADE
SMHP-772 STA 0+00.00
RIM: 1210.63
DEPTH: 16.83
NE FL IN: PROP 8" PVC 1195.13
W FL OUT: EX 24'' PVC 1193.80
EXISTING GRADEEXISTING
CART
PATH
EXISTING
PAVEMENT
PROP 8" PVC
0.50%
PROP 8" C900 DR-18 PVC
0.50%
PROP 8" PVC
2.33%
INSTALL 231 LF OF 8 INCH
SANITARY SEWER
EXISTING
PAVEMENT
EXISTING
PAVEMENT EXISTING
CART PATH
A2
A3
A1 STA 2+30.61
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1216.40
DEPTH: 15.90
N FL IN: PROP 8" PVC 1200.55
SW FL OUT: PROP 8" PVC 1200.50
SMHP-772
A1
A4
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
UNKNOWN UTILITY
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
220 LF OF STEEL
CASING FOR BORING
(8-INCH CARRIER)
EXISTING UNDERGROUND ELECTRIC
OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
EXISTING GAS LINE
(SIZE AND DEPTH
UNKNOWN)
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
THE LOCATION OF EXISTING SANITARY LATERALS
SHOWN ARE CONSIDERED TO BE APPROXIMATE
ONLY. THE CONTRACTOR SHALL VERIFY THE
EXACT LOCATION OF THE EXISTING SANITARY
LATERALS CONTRACTOR IN THE FIELD.
UNKNOWN UTILITY
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWNUNKNOWN UTILITIES
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
UNDERGROUND
ELECTRIC
OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
EXISTING GAS LINE
(SIZE AND DEPTH
UNKNOWN)
EXISTING SAN LINE
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
UNKNOWN UTILITIES
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
EXISTING WATER
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
EXISTING WATER
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
SELECT FILL,
CLASS "A" AGGREGATE,
COMPACTED TO 100%
UNDER PAVEMENT SECTIONS
RE: TAFB DET. A-UT-1
(TYP.)
A4STA 11+31.54
PROPOSED SANITARY SEWER MANHOLE (48")
MH: A4
RIM: 1215.89
DEPTH: 10.65
S FL OUT: PROP 8" PVC 1205.24
S FL IN: 8 '' PVC PIPE 1205.24
A4
PROP 8" PVC
0.50%
STA. 11+26.54
INV. EL. = 1205.44
4" WYE CONNECTION
TO PROPOSED 8"
PVC MAIN
STA. 10+17.87
END BORINGSTA. 7+97.87
START BORING
STA. 4+18.26
END BORING
UNDER STREET
STA. 3+40.26
START BORING
UNDER STREET
INSTALL 195 LF OF 8 INCH
SANITARY SEWER
INSTALL 385 LF OF 8 INCH
SANITARY SEWER
78 LF OF STEEL
CASING FOR BORING
(8-INCH CARRIER)
-0+40 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+40
A2 STA 4+25.38
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1213.80
DEPTH: 12.28
NE FL IN: PROP 8" C900 DR-18 PVC 1201.65
S FL OUT: PROP 8" PVC 1201.52
A3 STA 7+46.32
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1216.63
DEPTH: 13.38
N FL IN: PROP 8" PVC 1203.33
SW FL OUT: PROP 8" C900 DR-18 PVC 1203.25
INSTALL 321 LF OF 8 INCH
C900 DR-18 PVC
SANITARY SEWER
(SEE NOTE 1)
EXISTING
GRADE
SMHP-772 STA 0+00.00
RIM: 1210.63
DEPTH: 16.83
NE FL IN: PROP 8" PVC 1195.13
W FL OUT: EX 24'' PVC 1193.80
EXISTING GRADEEXISTING
CART
PATH
EXISTING
PAVEMENT
PROP 8" PVC
0.50%
PROP 8" C900 DR-18 PVC
0.50%
PROP 8" PVC
2.33%
INSTALL 231 LF OF 8 INCH
SANITARY SEWER
EXISTING
PAVEMENT
EXISTING
PAVEMENT EXISTING
CART PATH
A2
A3
A1 STA 2+30.61
PROPOSED SANITARY SEWER MANHOLE (48")
RIM: 1216.40
DEPTH: 15.90
N FL IN: PROP 8" PVC 1200.55
SW FL OUT: PROP 8" PVC 1200.50
SMHP-772
A1
A4
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
UNKNOWN UTILITY
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
220 LF OF STEEL
CASING FOR BORING
(8-INCH CARRIER)
EXISTING UNDERGROUND ELECTRIC
OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
EXISTING GAS LINE
(SIZE AND DEPTH
UNKNOWN)
WATER LINE PER OKC GIS DATA
(SIZE AND DEPTHS UNKNOWN)
THE LOCATION OF EXISTING SANITARY LATERALS
SHOWN ARE CONSIDERED TO BE APPROXIMATE
ONLY. THE CONTRACTOR SHALL VERIFY THE
EXACT LOCATION OF THE EXISTING SANITARY
LATERALS CONTRACTOR IN THE FIELD.
UNKNOWN UTILITY
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWNUNKNOWN UTILITIES
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
UNDERGROUND
ELECTRIC
OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
EXISTING GAS LINE
(SIZE AND DEPTH
UNKNOWN)
EXISTING SAN LINE
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
UNKNOWN UTILITIES
PER OKC GIS DATA
(SIZE AND DEPTHS
UNKNOWN)
EXISTING WATER
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
EXISTING WATER
PER OKC GIS DATA
(SIZE & DEPTH
UNKNOWN)
SELECT FILL,
CLASS "A" AGGREGATE,
COMPACTED TO 100%
UNDER PAVEMENT SECTIONS
RE: TAFB DET. A-UT-1
(TYP.)
A4STA 11+31.54
PROPOSED SANITARY SEWER MANHOLE (48")
MH: A4
RIM: 1215.89
DEPTH: 10.65
S FL OUT: PROP 8" PVC 1205.24
S FL IN: 8 '' PVC PIPE 1205.24
A4
PROP 8" PVC
0.50%
STA. 11+26.54
INV. EL. = 1205.44
4" WYE CONNECTION
TO PROPOSED 8"
PVC MAIN
STA. 10+17.87
END BORINGSTA. 7+97.87
START BORING
STA. 4+18.26
END BORING
UNDER STREET
STA. 3+40.26
START BORING
UNDER STREET
INSTALL 195 LF OF 8 INCH
SANITARY SEWER
INSTALL 385 LF OF 8 INCH
SANITARY SEWER
78 LF OF STEEL
CASING FOR BORING
(8-INCH CARRIER)
R
EV
N
O
D
AT
E D
R W
N C
H
KD
R
EM
AR
KS
SC
SH
O
W N
C
IT
Y O
F O
KL
AH
O M
A C
IT
Y
PR
O
JE
C
T N
O . T
S-
T
IN
KE
R A
FB
L
IF
T
ST
AT
IO
N
E
LI
M
IN
AT
IO
N
AR
EA
A
TS
-0
SH
EE
T N
O
SH
C
IV
IL
D
-2
D R
AW
N
B Y:
P M
G /M
R K
C H
EC
KE
D B
Y:
M
JS
40' 80'0
M
AT
C H
L
IN
E
ST
A
+0
SCALE: 1" = 40'
PLAN VIEW - SITE 1 ROUTE A1
SCALE: 1" = 40' (H) ; 1" = 4' (V)
PROFILE VIEW - SITE 1 ROUTE A2
C
SA
NI
TA
RY
S
EW
ER
S
IT
E
RO
UT
E
A
PL
AN
A
ND
P
RO
FI
LE
NOTES:
1) THE SEPARATION BETWEEN THE EXISTING WATER LINES AND NEW
SANITARY SEWER BETWEEN MH A2 AND MH A3 IS LESS THAN 10-FEET.
THE NEW 8-INCH SANITARY SEWER SHALL BE C900 DR-18 PVC AND
PRESSURE TESTED TO ASSURE WATER TIGHTNESS OF JOINTS
ADJACENT TO THE EXISTING WATER LINE PRIOR TO BACKFILLING IN
ACCORDANCE WITH OKLAHOMA DEQ REQUIREMENTS
2) TINKER AFB GOLF COURSE SPECIAL INSTRUCTIONS:
A) CONTRACTOR SHALL WORK DILIGENTLY TO MINIMIZE DISRUPTIONS TO
GOLF COURSE OPERATIONS AND MAINTENANCE DURING
CONSTRUCTION.
B) TO MINIMIZE DAMAGE TO EXISTING SOD, CONTRACTOR WILL PROVIDE A
PLYWOOD OR OTHER SURFACE TO PROTECT THE SOD AND CART PATHS
FROM VEHICLE DAMAGE.
C) ANY SOD DAMAGED DURING CONSTRUCTION SHALL BE REPLACED WITH
TAHOMA 31 SOD ON CLOSELY CUT APRONS DIRECTLY ADJACENT TO THE
PRACTICE PUTTING GREEN SURFACE AND 9 IRON/ASTRO BERMUDA
GRASS SOD ON ALL OTHER DISTURBED AREAS OF THE GOLF COURSE.
WHERE ASPHALT CART PATHS ARE DAMAGE THEY SHALL BE REPLACED
IN LIKE OR BETTER CONDITION.
D) ACCESS TO THE MAIN PARKING LOT MUST REMAIN OPEN FOR THE
ENTIRE DURATION OF CONSTRUCTION ON THE GOLF COURSE. THE
CONTRACTOR SHALL PROVIDE A PLAN TO MAINTAIN ACCESS TO THE
ENGINEER AS A SHOP DRAWING. THE PLAN MUST SHOW SIGNAGE,
TRENCH PROTECTION, AND ANY OTHER REQUIRED TRAFFIC CONTROL
DETAILS DEEMED NECESSARY.
E) CONTRACTOR WILL COORDINATE CONSTRUCT SEQUENCING WITH THE
ENGINEER AND THE GOLF COURSE STAFF.
3) THE EXISTING UTILITIES SHOWN IN THE PLAN VIEW ON THIS SHEET ARE
A COMBINATION OF FIELD DATA COLLECTION AND GIS DATA. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE EXISTING UTILITY
LOCATIONS.
4) CONTRACTOR MUST SUBMIT AN OUTAGE REQUEST FOR ANY
INTERRUPTION IN ROADS, SIDEWALKS, OR PARKING LOTS AT LEAST 45
CALENDAR DAYS IN ADVANCE OF IMPACTS.
NO
RTH
AutoCAD SHX Text COULD NOT VERIFY EXACT LOCATION OF CONNECTION TO SANITARY SYSTEM, APPROXIMATE AND ASSUMED LOCATION SHOWN WITH SS|A| LINETYPE
AutoCAD SHX Text
ARNOLD STREET
AutoCAD SHX Text H
AutoCAD SHX Text S
AutoCAD SHX Text H
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text C
AutoCAD SHX Text V
AutoCAD SHX Text G
AutoCAD SHX Text V
AutoCAD SHX Text G
AutoCAD SHX Text
MITCHELL AVENUE
AutoCAD SHX Text
14" TREE (TAGGED 5853)
AutoCAD SHX Text
20" TREE
AutoCAD SHX Text
24" TREE
AutoCAD SHX Text
8" TREE
AutoCAD SHX Text
24" CEDAR
AutoCAD SHX Text
24" TREE
AutoCAD SHX Text
14" TREE (TAGGED 4912)
AutoCAD SHX Text
RETAINING WALL
AutoCAD SHX Text
ASPHALT CART PATH
AutoCAD SHX Text
ASPHALT CART PATH
AutoCAD SHX Text
ASPHALT CART PATH
AutoCAD SHX Text
CLEANOUT COULD NOT OPEN
AutoCAD SHX Text
CLEANOUT LID:1217.76 FL:1216.78
AutoCAD SHX Text
CLEANOUT LID:1218.21 FL:1215.12
AutoCAD SHX Text SMHP-772 RIM:1210.63 NW FL IN: PROP. 8" PVC 1195.47 WNW 24" PVC FL:1193.80 SW 24" PVC FL:1193.80
AutoCAD SHX Text
SPUP-107 RIM:1209.21
AutoCAD SHX Text SMHP-1170 RIM:1212.43 SW 6" VCP FL:1208.91 FL:1208.91 1208.91 NE 6" VCP FL:1208.94 FL:1208.94 1208.94 NNE 8" VCP FL:1212.43FL:1212.431212.43
AutoCAD SHX Text P:\140_CivInf\1400390 COC Tinker AFB Lft Stn TS0007\21DesignWorking\CIVL\05AutoCAD\2Sheets\1400390-PLAN & PROFILES.dwg
5/19/2025 11:05 AM
11+00 11+50 12+00 12+50 13+00 13+50
EX
IS
TI
N
G M
ET
AL
B U
IL
D
IN
G
(B
LD
G
2)
EXISTING WATER LINE
PER OKC GIS DATA
(SIZE AND
DEPTHS UNKNOWN)
EXISTING UNDERGROUND
ELEC PER OKC GIS DATA
(SIZE AND
DEPTHS UNKNOWN)
SELECT FILL,
CLASS "A" AGGREGATE,
COMPACTED TO 100%
UNDER PAVEMENT SECTIONS
RE: TAFB DET. A-UT-1
(TYP.)
INSTALL 174 LF OF 4 INCH
SANITARY SEWER
PROP 4" PVC
2.00%
EXISTING
PAVEMENT
STA. 12+95.48
PROPOSED 2-WAY
CLEANOUT
STA. 11+26.54
INV. EL. = 1205.44
4" WYE CONNECTION
TO PROPOSED 8"
PVC MAIN
11+00 11+50 12+00 12+50 13+00 13+50
EX
IS
TI
N
G M
ET
AL
B U
IL
D
IN
G
(B
LD
G
2)
EXISTING WATER LINE
PER OKC GIS DATA
(SIZE AND
DEPTHS UNKNOWN)
EXISTING UNDERGROUND
ELEC PER OKC GIS DATA
(SIZE AND
DEPTHS UNKNOWN)
SELECT FILL,
CLASS "A" AGGREGATE,
COMPACTED TO 100%
UNDER PAVEMENT SECTIONS
RE: TAFB DET. A-UT-1
(TYP.)
INSTALL 174 LF OF 4 INCH
SANITARY SEWER
PROP 4" PVC
2.00%
EXISTING
PAVEMENT
STA. 12+95.48
PROPOSED 2-WAY
CLEANOUT
STA. 11+26.54
INV. EL. = 1205.44
4" WYE CONNECTION
TO PROPOSED 8"
PVC MAIN
S
ROUTE A
CONSTRUCTION
LIMITS
PAVEMENT
REPLACEMENT
36 SY
SS
SS
SS
STA 12+90.48
PROPOSED
2-WAY CLEANOUT
10' FROM BUILDING FOUNDATION
STA 13+00.48
CONNECT PROPOSED LATERAL
TO EXISTING BUILDING
(BLDG 6642)
STA 11+26.54
4" WYE CONNECTION
TO 8" PVC MAIN
PROPOSED
MANHOLE A4
' C
ONST
RUCTI
ON LI
MIT
S
(T
YP
S
ROUTE A
CONSTRUCTION
LIMITS
PAVEMENT
REPLACEMENT
36 SY
SS
SS
SS
STA 12+90.48
PROPOSED
2-WAY CLEANOUT
10' FROM BUILDING FOUNDATION
STA 13+00.48
CONNECT PROPOSED LATERAL
TO EXISTING BUILDING
(BLDG 6642)
STA 11+26.54
4" WYE CONNECTION
TO 8" PVC MAIN
NOTE:
CONTRACTOR SHALL MAINTAIN
CARTPATH ACCESS TO BLDG 6642
DURING CONSTRUCTION
EXISTING LIFT STATION #6642
TO BE ABANDONED
ABANDONMENT OF LIFT STATIONS WILL CONSIST OF
A) REMOVING THE PUMP BASIN AND ALL PUMPS, MOTORS,
COUPLINGS, VALVES, CONTROL PANELS, INSTRUMENTATION,
ELECTRICAL SERVICE, AND ALL APPURTENANCES ABOVE
FINISHED GRADE; AND
B) CUTTING DOWN UNNEEDED FACILITIES TO FOUR FEET
BELOW GRADING, FILLING WITH CEMENT STABILIZED SAND,
AND COVERING WITH TOPSOIL TO GRADE. WHERE LIFT
STATIONS ARE LOCATED IN SIDEWALKS, THE EXCAVATION
WILL BE FILLED WITH TYPE A AGGREGATE AND THE
SIDEWALK REPAIRED WITH CONCRETE IN LIKE NEW OR
BETTER CONDITION. ELECTRICAL AND CONTROL WIRING
WILL BE REMOVED BACK TO SOURCE AND CONDUIT WILL BE
CUT UNDERGROUND AND ABANDONED IN-PLACE. ANY
EXISTING ASSOCIATED SERVICE LINES & FORCE MAIN THAT
WILL NO LONGER BE UTILIZED WILL BE…