This is a project plan document for the Lahaina Small Boat Harbor Front Row Piers and Dinghy Dock Repairs prepared by the State of Hawaii Department of Land and Natural Resources, Division of Boating and Ocean Recreation. The project is located in Lahaina on the Island of Maui, Hawaii (T.M.K.: (2) 4-6-001: 002) and is designated as Job Number B46CM71B. The scope of work requires contractors to furnish and pay for all materials, tools, equipment, labor, and incidental work necessary for the repair and restoration of the front row piers and dinghy dock, including water and electrical utilities, in accordance with the Notice to Bidders, Proposal documents, Plans, Specifications, Permitting Documents, and General Conditions.
The plans document contains comprehensive technical drawings and specifications across multiple sheets, including existing site plans, boring logs, demolition plans and photographs, erosion and sediment control plans and details, general and enlarged site plans, water system site plans, layout plans, foundation plans, finger pier and mooring pile plans, typical deck sections, pile embedment details, and electrical infrastructure specifications. The electrical work includes 480/277V and 120/240V service equipment with detailed fault current calculations for multiple slip connections, switchboard details, transformer pad details, and electrical rack and bollard specifications. The project incorporates precast/prestressed pile systems and appears to involve significant structural restoration work across the harbor's front row infrastructure.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF LAND AND NATURAL RESOURCES
LAHAINA SMALL BOAT HARBOR
FRONT ROW PIERS AND
DINGHY DOCK REPAIRS
LAHAINA, ISLAND OF MAUI, HAWAI’I
T.M.K.: (2) 4-6-001: 002
JOB NO. B46CM71B
STATE OF HAWAI’I
DIVISION OF BOATING AND OCEAN RECREATION
C-00
B
I US
AHAWA I
Q.H.MAILLI
W
WO
C-01
GENERAL NOTES
AHAWA I
Q.H.MAILLI
W
WO
C-02
EROSION AND SEDIMENT
CONTROL NOTES
AHAWA I
Q.H.MAILLI
W
WO
EXISTING SITE PLAN
C-03
AHAWA I
Q.H.MAILLI
W
WO
BORING LOGS
C-04
AHAWA I
Q.H.MAILLI
W
WO
DEMOLITION PLAN
C-05
AHAWA I
Q.H.MAILLI
W
WO
DEMOLITION PHOTOGRAPHS - 1
C-06
AHAWA I
Q.H.MAILLI
W
WO
DEMOLITION PHOTOGRAPHS - 2
C-07
AHAWA I
Q.H.MAILLI
W
WO
DEMOLITION PHOTOGRAPHS - 3
C-08
AHAWA I
Q.H.MAILLI
W
WO
EROSION AND SEDIMENT
CONTROL PLAN
C-09
AHAWA I
Q.H.MAILLI
W
WO
GENERAL SITE PLAN
C-10
AHAWA I
Q.H.MAILLI
W
WO
ENLARGED SITE PLAN
C-11
AHAWA I
Q.H.MAILLI
W
WO
WATER SYSTEM SITE PLAN
C-12
AHAWA I
Q.H.MAILLI
W
WO
EROSION AND SEDIMENT
CONTROL DETAILS
C-13
AHAWA I
Q.H.MAILLI
W
WO
MISCELLANEOUS DETAILS
C-14
EMBEDMENT LENGTH SCHEDULE
TYPICAL REBAR SPLICE AND
LAYOUT PLAN
LAYOUT PLAN
FOUNDATION PLAN
FOUNDATION PLAN
FINGER PIER AND MOORING PILE PLAN
TYPICAL FINGER PIER PLAN
TYPICAL FLOATING DOCK PLAN
FINGER PIER AND MOORING PILE FRAMING PLAN
TYPICAL FINGER PIER FRAMING PLAN
SECTION THROUGH CENTERLINE AT FINGER PIER
SECTION THROUGH PILE CENTERLINE AT FLOATING DOCK
TYPICAL DECK SECTIONS
20" OCTAGONAL PRECAST/PRESTRESSED PILE
PILE EMBEDMENT DETAILSECTION
PILE PICK UP POINTS
SECTION AT TYPICAL PILE CAP SECTION
From To Isc at Source (A) VLL Phase Length (ft) # Sets Conductor
Size Conductor
Type Conduit
Type C f m Isc(available) (A) Note
Utility XFMR Secondary 480/277V Service Equipment 26,800 amps 480 V 3 10'-0'' 1 #3/0 Copper Nonmetallic 13,923 0.0695 0.9351 25,059 amps
480/277V Service Equipment
Enclosed Circuit Breaker 25,059 amps 480 V 3 220'-0'' 1 #1/0 Copper Nonmetallic 9,317 2.1352 0.3190 7,993 amps
Point to Point Fault Current Calculations
From To Isc at Source (A) VLL Phase Length (ft) # Sets Conductor
Size Conductor
Type Conduit
Type C f m Isc(available) (A) Note
Utility XFMR Secondary 120/240V Service Equipment 25,700 amps 240 V 1 10'-0'' 1 #300kcmil Copper Nonmetallic 20,868 0.1026 0.9069 23,308 amps
120/240V Service Equipment Slip 0 23,308 amps 240 V 1 173'-0'' 1 #4 Copper Nonmetallic 3,826 8.7826 0.1022 2,383 amps 120/240V Service Equipment Slip 1 23,308 amps 240 V 1 173'-0'' 1 #4 Copper Nonmetallic 3,826 8.7826 0.1022 2,383 amps 120/240V Service Equipment Slip 2 23,308 amps 240 V 1 175'-0'' 1 #4 Copper Nonmetallic 3,826 8.8841 0.1012 2,358 amps 120/240V Service Equipment Slip 3 23,308 amps 240 V 1 175'-0'' 1 #4 Copper Nonmetallic 3,826 8.8841 0.1012 2,358 amps 120/240V Service Equipment Slip 4 23,308 amps 240 V 1 210'-0'' 1 #4 Copper Nonmetallic 3,826 10.6610 0.0858 1,999 amps 120/240V Service Equipment Slip 6 23,308 amps 240 V 1 242'-0'' 1 #4 Copper Nonmetallic 3,826 12.2855 0.0753 1,754 amps 120/240V Service Equipment Slip 7 23,308 amps 240 V 1 280'-0'' 1 #2 Copper Nonmetallic 6,044 8.9982 0.1000 2,331 amps 120/240V Service Equipment Slip 8 23,308 amps 240 V 1 280'-0'' 1 #2 Copper Nonmetallic 6,044 8.9982 0.1000 2,331 amps 120/240V Service Equipment Slip 9 23,308 amps 240 V 1 305'-0'' 1 #2 Copper Nonmetallic 6,044 9.8016 0.0926 2,158 amps 120/240V Service Equipment Slip 10 23,308 amps 240 V 1 305'-0'' 1 #2 Copper Nonmetallic 6,044 9.8016 0.0926 2,158 amps 120/240V Service Equipment Slip 11 23,308 amps 240 V 1 350'-0'' 1 #1 Copper Nonmetallic 7,493 9.0727 0.0993 2,314 amps 120/240V Service Equipment Slip 12 23,308 amps 240 V 1 350'-0'' 1 #1 Copper Nonmetallic 7,493 9.0727 0.0993 2,314 amps 120/240V Service Equipment Slip 13 23,308 amps 240 V 1 386'-0'' 1 #1 Copper Nonmetallic 7,493 10.0058 0.0909 2,118 amps 120/240V Service Equipment Slip 14 23,308 amps 240 V 1 386'-0'' 1 #1 Copper Nonmetallic 7,493 10.0058 0.0909 2,118 amps 120/240V Service Equipment Slip 15 23,308 amps 240 V 1 440'-0'' 1 #1/0 Copper Nonmetallic 9,317 9.1727 0.0983 2,291 amps 120/240V Service Equipment Slip 16 23,308 amps 240 V 1 440'-0'' 1 #1/0 Copper Nonmetallic 9,317 9.1727 0.0983 2,291 amps 120/240V Service Equipment Slip 17 23,308 amps 240 V 1 475'-0'' 1 #1/0 Copper Nonmetallic 9,317 9.9024 0.0917 2,138 amps 120/240V Service Equipment Slip 18/19 23,308 amps 240 V 1 475'-0'' 1 #1/0 Copper Nonmetallic 9,317 9.9024 0.0917 2,138 amps 120/240V Service Equipment Slip 20 23,308 amps 240 V 1 511'-0'' 1 #1/0 Copper Nonmetallic 9,317 10.6529 0.0858 2,000 amps 120/240V Service Equipment Slip 21 23,308 amps 240 V 1 511'-0'' 1 #1/0 Copper Nonmetallic 9,317 10.6529 0.0858 2,000 amps 120/240V Service Equipment Slip 22 23,308 amps 240 V 1 532'-0'' 1 #2/0 Copper Nonmetallic 11,424 9.0452 0.0996 2,320 amps 120/240V Service Equipment Slip 22 23,308 amps 240 V 1 532'-0'' 1 #2/0 Copper Nonmetallic 11,424 9.0452 0.0996 2,320 amps 120/240V Service Equipment Slip 23 23,308 amps 240 V 1 580'-0'' 1 #2/0 Copper Nonmetallic 11,424 9.8613 0.0921 2,146 amps 120/240V Service Equipment Slip 23 23,308 amps 240 V 1 580'-0'' 1 #2/0 Copper Nonmetallic 11,424 9.8613 0.0921 2,146 amps
Point to Point Fault Current Calculations
ORNEJ.
I L
LY
LL
SA
ENGINEER
PROFESSIONAL
A.
S.
U.IAWAH
I
No. 11658-E
LICENSED
E-302
SWITCHBOARD DETAIL 1
I L
LY
LL
SA
ENGINEER
PROFESSIONAL
A.
S.
U.IAWAH
I
No. 11658-E
LICENSED
E-303
SWITCHBOARD DETAIL 2
I L
LY
LL
SA
ENGINEER
PROFESSIONAL
A.
S.
U.IAWAH
I
No. 11658-E
LICENSED
E-304
ELECTRICAL RACK AND BOLLARD
I L
LY
LL
SA
ENGINEER
PROFESSIONAL
A.
S.
U.IAWAH
I
No. 11658-E
LICENSED
E-305
TRANSFORMER PAD DETAIL
| Sheets and Views |
| C-00 Lahaina SBH Front Row - Title Sheet-C-00 |
| C-01 Lahaina SBH Front Row - General Notes-C-01 |
| C-02 Lahaina SBH Front Row - Erosion and Sediment Control Notes-C-02 |
| C-03 Lahaina SBH Front Row - Existing Site Plan-C-03 |
| C-04 Lahaina SBH Front Row - Boring Logs-C-04 |
| C-06 to C-08 Lahaina SBH Front Row - Demolition Photographs-C-06 |
| C-06 to C-08 Lahaina SBH Front Row - Demolition Photographs-C-07 |
| C-06 to C-08 Lahaina SBH Front Row - Demolition Photographs-C-08 |
| C-09 Lahaina SBH Front Row - Erosion and Sediment Control Plan-C-09 |
| C-13 to C-14 Lahaina SBH Front Row - Miscellaneous Details-C-13 |
| C-13 to C-14 Lahaina SBH Front Row - Miscellaneous Details-C-14 |
File details come from the government source that posted it. Updated .