Plans - 20 MAR 2-26_D6_Tipton _DC.pdf
PDF 19 MB Posted
- Attached to
- Tipton Building Re-Roof
- Solicitation number
- 645-DOTRFQ-2734-2026
- Issued by
- Muscatine County, Iowa
About this file
This is a set of architectural plans issued by the Iowa Department of Transportation (Iowa DOT) for the Tipton Maintenance Garage roof repair project located at 2092 Moscow County Road X54, Tipton, Iowa 52772 (Project Number BG-1T11 (019)--80-16). The plans detail the complete removal and replacement of the existing shingle roof with 26-gauge metal roof panels, including removal of ridge vents, gutters, flashing, and all roofing materials down to the substrate. The project includes repair of damaged roof sheathing, installation of bituminous underlayment over the entire roof, salvage and reinstallation of existing gutters, installation of new reglets and metal flashing at wall interfaces, and incorporation of metal rake trim and snow guards. The plans are dated March 20, 2026, and encompass eight sheets including cover, existing condition images, detailed roof plan with dimensions of approximately 40 feet by 24 feet, and multiple construction details at various scales showing reglet, gutter edge, and rake edge specifications.
The contractor is responsible for field verification of all roof dimensions, slopes, and system locations, and must provide weather-proofing tarps during construction and manage all debris removal to EPA-compliant waste management facilities. The contractor must notify the owner immediately of any structural issues discovered during demolition, provide uplift diagrams demonstrating compliance with ASCE 7-10 or 7-16 wind pressure standards, and coordinate all metal trim and panel specifications with the manufacturer. The plans emphasize contractor accountability for damage to existing and newly installed items not designated for removal, and require submission of an appropriate roofing system design meeting specified wind uplift pressures with manufacturer verification of all metal components prior to installation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Project Manual - D6-TIPTON MG ADDITION ROOF REPAIR 05-08-2026 02-37-22 PM.pdf | ||
| 1386968-event.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION: SITE LOCATION:
TIPTON MG
MG ADDITION
4 5
CEDAR
IOWA COUNTY AND DISTRICT KEY
PROJECT:
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES / RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
D6-TIPTON MG ADDITION
ROOF REPAIR
BG-1T11 (019)--80-16
2092 Moscow County Rd X54, Tipton, IA 52772
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A001
COVER
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
DAMAGED ROOF AREA,
CONTRACTOR TO NOTIFY OWNER
AFTER DEMO TO THE EXTENT OF
DAMAGE AND IF STRUCTURAL
ISSUES ARE PRESENT
REMOVE RIDGE VENT
REMOVE ALL SHINGLES
AND UNDERLAYMENT
REMOVE
GUTTERS AND
SALVAGE FOR
REUSE, TYP.
SEE A003 FOR ENLARGED IMAGES
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A002
IMAGES
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
DEMOLITION NOTES
1. ROOF CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS, ROOF SLOPES AND LOCATIONS OF ROOF
SYSTEMS (V.I.F. = VERIFY INFIELD).
2. ROOF CONTRACTOR TO FIX, PATCH, REINFORCE, AND REPAIR EXISTING ROOF PRIOR TO INSTALLATION
OF NEW ROOFING SYSTEM.
3. ROOF CONTRACTOR TO PROVIDE A TARP FOR WEATHER-PROOFING ROOF DURING CONSTRUCTION.
4. ROOF CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS TO A WASTE MANAGEMENT FACILITY PER
EPA REQUIREMENTS.
5. ROOF CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL DEBRIS FOR DISPOSAL OFF SITE.
6. ROOF CONTRACTOR IS RESPONSIBLE FOR DAMAGE TO EXISTING & NEWLY INSTALLED ITEMS NOT
NOTED FOR REMOVAL - CONTACT OWNER IMMEDIATELY IF DAMAGE OCCURS.
7. REMOVE GUTTERS, SALVAGE FOR REUSE
EXISTING CONDITIONS AT DAMAGED
AREA AND DEMO NOTES
REMOVE ALL FLASHING AND
SEALANT ON BOTH SIDES
OF ROOF, CLEAN BRICK IN
PREPARATION FOR REGLET
AND FLASHING
REMOVE ALL ROOFING
AND UNDERLAYMENT
REMOVE AND SALVAGE
GUTTER FOR REUSE
REMOVE ALL
ROOFING AND
UNDERLAYMENT
REMOVE ALL FLASHING
AND SEALANT ON BOTH
SIDES OF ROOF, CLEAN
BRICK IN PREPARATION
FOR REGLET AND
FLASHING
REMOVE WALL ANCHOR
AND CLEAN AREA IN
PREPARATION FOR
REGLET
REMOVE ALL ROOFING AND
UNDERLAYMENT
REMOVE ALL FLASHING AND
SEALANT ON BOTH SIDES
OF ROOF, CLEAN BRICK IN
PREPARATION FOR REGLET
AND FLASHING
CUT PVC AND REMOVE LOWER
PORTION
REMOVE WALL ANCHOR
AND CLEAN AREA IN
PREPARATION FOR REGLET
CUT PVC AND REMOVE
LOWER PORTION
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A003
IMAGES
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
EXISTING CONDITIONS AT DAMAGED
AREA AND DEMO NOTES
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A004
IMAGES
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A005
IMAGES
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
A103
EXISTING MG
40' - 0" VERIFY
CONT. RIDGE VENT.
MODIFY SUBSTRATE IF
NEEDED TO FACILITATE
NEW VENT TYP.
NEW REGLET AT
WALL TYP.
V
E R
IF
Y
A102
A103
TYP.
AREA OF ROOF
SHEATHING REPAIR
METAL ROOF
PANELS PER MFG.
TYP.
WALL LINE
BELOW, TYP.
SALVAGED GUTTERS
REINSTALLED, TYP.
BITUMINOUS
UNDERLAYMENT
OVER ENTIRE
ROOF
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A101
PLAN AND NOTES
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
1/8" = 1'-0"A101
1 ROOF PLAN
N O
R T
H
ROOF PLAN NOTES
1. CONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL ADDITIONAL DEBRIS AND DISPOSAL OFF SITE
2. STRUCTURAL ISSUES AND REPAIRS ARE INCLUDED IN THIS PROPOSAL. CONTRACTOR TO NOTIFY
OWNER IMMEDIATELY OF THESE ISSUES.
3. CONTRACTOR TO PROVIDE APPROPRIATE ROOFING SYSTEM IN ACCORDANCE WITH ASCE 7-10 OR 7-16
TO MEET DESIGN WIND UPLIFT PRESSURES.
4. CONTRACTOR TO PROVIDE UPLIFT DIAGRAM SHOWING PRESSURES/LOADS FOR REVIEW.
5. VERIFY ALL METAL TRIMS AND PANELS WITH METAL PANEL SUPPIER
EXISTING BUILDING
26 GA. METAL
ROOF PANEL
PER MFG.
METAL
RAKE TRIM
PER MFG.
EXISTING
METAL
FASCIA TO
REMAIN
BITUMINOUS UNDERLAYMENT OVER ENTIRE ROOF
EXISTING MG
NEW REGLET AND FLASHING
SALVAGED GUTTERS
REINSTALLED, TYP.
A103
EXISTING BUILDING ADDITION
A102
CONT RIDGE VENT, TYP.
METAL RAKE TRIMEXIST METAL
FASCIA TRIM
TO REMAIN
VERIFY
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A102
DETAILS
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
1/8" = 1'-0"A102
2 NORTH ELEVATION
3" = 1'-0"A102
1 RAKE EDGE DETAIL
DEPTH PER MFG.
W
ID
T H
P E
R M
F G
METAL FLASHING
BACKER ROD AND SEALANT
OVER SOFT METAL WEDGE
FOR FRICTION FIT
EXISTING ROOF SHEATHING
EXTERIOR BRICK WALL SURFACE
PRE-FINISHED METAL
COUNTERFLASHING
26 GA. METAL ROOF PANELS
ANCHOR PER SPEC. WITH
METAL FINISH TRIM AT WALL
BITUMINOUS UNDERLAYMENT
TURNED UP WALL
V E
R
IF
Y O
V E
R A
L L
W
M F
G
SALVAGED
GUTTER
REINSTALLED
EXISTING BUILDING
26 GA. METAL ROOF PANEL, PER MFG.
ATTACH PER SPEC.CORRUGATED
CLOSURE STRIP,
PER MFG.
BITUMINOUS UNDERLAYMENT
OVER ENTIRE ROOF
METAL ROOF
SNOW GUARD
PER MFG.
GUTTER
APRON
PER MFG.
Project Number
Date
IOWA DEPARTMENT OF TRANSPORTATION
ARCHITECTURAL SERVICES /
RESOURCES & ACQUISITION BUREAU
800 Lincoln Way Ames, Iowa 50010 www.iowadot.gov
DISTRICT:
A103
DETAILS
BG-1T11 (019)--80-16
D6-TIPTON
MG ADDITION
ROOF REPAIR 20 MAR 2026
3" = 1'-0"A103
1 REGLET DETAIL
3" = 1'-0"A103
2 GUTTER EDGE DETAIL
| Sheets |
| A001 - COVER |
| A002 - IMAGES |
| A003 - IMAGES |
| A004 - IMAGES |
| A005 - IMAGES |
| A101 - PLAN AND NOTES |
| A102 - DETAILS |
| A103 - DETAILS |
File details come from the government source that posted it. Updated .