This document is a comprehensive set of technical design and construction plans for the Video Management System Upgrade Phase 1 project at Baraga Correctional Facility in Baraga, Michigan, prepared by the State of Michigan Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division. The plans, dated November 19, 2021, with 50%, 90%, and 97% owner review updates through April 15, 2022, detail the installation and configuration of a new video security system across multiple buildings and perimeter locations at the facility. The project includes installation of numerous security cameras (both fixed and pan-tilt-zoom models) throughout eight housing units, administrative buildings, support services, education, and maintenance facilities, along with new and replacement communications infrastructure, networking equipment, fiber optic cabling, and monitoring stations. The scope encompasses camera mounting details, cable labeling specifications, equipment schedules, rack layouts, connectivity diagrams, and grounding details for the entire campus security system.
The plans specify extensive technical requirements including CAT-6 cabling systems, fiber optic backbone connectivity (both existing 12 and 24-strand single-mode and multimode configurations), Ethernet switches (including Cisco C9300 and C9200 series), network video recorders, multiple monitoring stations with LCD displays, uninterruptible power supplies, lightning arrestors, patch panels, and associated mounting hardware and accessories. Equipment manufacturers and part numbers are detailed throughout, including Panasonic, Axis, Hubbell, Cisco, Comnet, and NEC products. The construction plans require coordination between the electrical contractor for conduit and power installation and the communications contractor for all cabling, equipment installation, configuration, and testing. Key installation locations include nine perimeter cabinets (CAB-001 through CAB-009), multiple light poles throughout the facility perimeter, and communications rooms in the administration, education, support services, and maintenance buildings, with new rack installations specified where required to accommodate new server and networking equipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Plans 3 of 4 21301.pdf | ||
| Plans 4 of 4 21301.pdf | ||
| Addendum 1 21301.pdf | ||
| LEIN form 21301.pdf | ||
| Addendum 2 21301.pdf | ||
| Specification 21301.pdf | ||
| Plans 1 of 4 21301.pdf | ||
| Advertisement 21301.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TC101
TYPICAL PERIMETER CAMERA CABLE LABELS
AT FACEPLATE & PATCH PANEL
TC101
FIBER OPTIC CABLE AT PERIMETER CABINETS
LABELING AT PATCH PANEL
TC101
COMMUNICATIONS GROUNDING DETAIL
TC101
FIBER OPTIC PANEL
LABELING DETAIL
TC101
UTP PATCH PANEL (TYP)
TC101
TYPICAL DATA CABLE LABELING
AT FACEPLATE AND PATCH PANEL
TC101
TYPICAL FACEPLATE LABELING
COMMUNICATION CABLE SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
NETWORK EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
SECURITY EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
SECURITY SYMBOL LEGEND
SYMBOL DESCRIPTION
COMMUNICATION EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO.
ABBREVIATIONS
ABBREV. DESCRIPTION ABBREV. DESCRIPTION
PC
CAMERA EQUIPMENT SCHEDULE
MARK DESCRIPTION MANUFACTURER PART NO. DROP CEILING HARD
CEILING/WALL
BUILDING
EXTERIOR
BUILDING
EXTERIOR
CORNER
POLE MOUNT
TC101
CABLING LEGENDS,
DETAILS AND
SCHEDULES
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
AutoCAD SHX Text
%%UOUTLET IN CEILING
AutoCAD SHX Text
AAA-BBB-CCCC
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AA-BB-CCC
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AA-BB-CCC
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
AAA-BBB-CCCC
AutoCAD SHX Text
LABELS
AutoCAD SHX Text
AAA-BBB
AutoCAD SHX Text
CCCC
AutoCAD SHX Text
%%UWALL MOUNTED
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AA-BB-CCC
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text
AA-BB-CCC
AutoCAD SHX Text
%%UFIBER PANEL
AutoCAD SHX Text
FIBER CABLE
AutoCAD SHX Text
XXX-YYY/XXX-YYY ZZAA
AutoCAD SHX Text
%%URACK MOUNTED
AutoCAD SHX Text
%%UFIBER PANEL
AutoCAD SHX Text
XXX-YYY/XXX-YYY ZZAA
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
TELECOMMUNICATIONS
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text
#10 AWG
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
24 STRAND SM FIBER TO CAB-001
AutoCAD SHX Text
24 STRAND SM FIBER TO CAB-003
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
THIS IS CABINET CAB-002
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL (TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%URACK MOUNT FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UWALL MOUNT FIBER PANEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TO
AutoCAD SHX Text
CAB-001
AutoCAD SHX Text
SC CONNECTOR PANEL
AutoCAD SHX Text
24 SM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FIBER
AutoCAD SHX Text
CABLE
AutoCAD SHX Text
TO
AutoCAD SHX Text
CAB-003
AutoCAD SHX Text
24 SM
AutoCAD SHX Text
FIBER TO XXYY
AutoCAD SHX Text
FIBER TO XXYY
AutoCAD SHX Text
WRAP AROUND LABEL
AutoCAD SHX Text
BLANK PANEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL (TYP)
AutoCAD SHX Text
CAB-001 / CAB-002 12-SM
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LABEL PANELS CONSECUTIVELY IN THE COMM ROOM, A THRU Z
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONNECTIONS FOR PC'S (TYPICAL)
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ZZZZ
AutoCAD SHX Text
ADHESIVE LABEL WITH CAMERA NUMBER (TYP)
AutoCAD SHX Text %%uBACK OF FACEPLATE
AutoCAD SHX Text %%uBACK OF PATCH PANEL
AutoCAD SHX Text
AA-X-YY
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text
WRAP-AROUND LABEL
AutoCAD SHX Text 33-3204-02
AutoCAD SHX Text %%uIN COMM ROOM
AutoCAD SHX Text
AA-X-YY
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
AA-X
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
AA-X-YY
AutoCAD SHX Text
YY
AutoCAD SHX Text
YY
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text A-X
AutoCAD SHX Text
YY
AutoCAD SHX Text
YY
AutoCAD SHX Text
%%USURFACE MOUNT OUTLET
AutoCAD SHX Text
PAPER BEHIND
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
%%USTANDARD PLATE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text NOTES: 1. THE FIBER PANELS AT THE RACK AND AT THE EXTERIOR CABINETS SHALL BE LABELED TO IDENTIFY THE FIBER. 2. LABELS IDENTIFYING THE FIBER CABLES SHALL BE ENGRAVED LABELS WITH BLACK BACKGROUND AND WHITE LETTERS. 3. SIZE THE LABELS TO MATCH THE SIZE OF THE PANEL. PROVIDE A SAMPLE TO THE OWNER AND ENGINEER PRIOR TO PURCHASING 4. PROVIDE A WRAP-AROUND LABEL ON THE FIBER CABLE AS IT ENTERS THE PATCH PANEL. LASER PRINTED
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
ENGRAVED PHENOLIC LABEL
AutoCAD SHX Text
THIS IS CABINET CAB-002
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND SHALL BE SELF-LAMINATING. 3. WHEN LABELING PATCH PANELS IN A COMM ROOM, START AT THE TOP OF THE FIRST RACK AND THEN LABEL CONSECUTIVELY DOWN THE RACK AND THEN TOP TO BOTTOM IN OTHER RACKS.
AutoCAD SHX Text CAMERA CABLING LABEL A-Y-ZZ-YYY A = COMMUNICATIONS ROOM, A, B..ETC X = PATCH PANEL IN THAT RACK OR CABINET 1-X YY = PORT ON THAT PANEL FROM 01-24 ZZZZ = CAMERA NUMBER
AutoCAD SHX Text NOTES: 1. INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE 4. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL INSTALL A LABEL TO EACH PATCH PANEL DETAILING THE 4. THE CABLES SHALL BE TERMINATED ON THE PATCH PANEL COMM ROOM NUMBER AND THAT IT IS A SECURITY IN NUMERICAL CAMERA ORDER. NO EXCEPTIONS. PATCH PANEL. 2. ALL LABELS SHALL BE LASER PRINTED AND CUT TO FIT. 5. CABLES THAT ARE NOT CONNECTED TO A CAMERA SHALL BE ALL LABELS SHALL BE LASER PRINTED AND CUT TO FIT. 5. CABLES THAT ARE NOT CONNECTED TO A CAMERA SHALL BE ALL NUMBERS SHALL EXACTLY ALIGN WITH THE TERMINATED AT THE END OF THE PATCH PANELS AND SHALL LOCATION ON THE PATCH PANEL. NOT BE LABELED WITH THE ZZZ ON THEM. 3. EACH PORT SHALL BE LABELED FOR THE CAMERA NUMBER TO WHICH THE PORT IS CONNECTED IF IT IS CONNECTED TO A CAMERA.
AutoCAD SHX Text CAMERA CABLING LABEL A-X-YY AA = COMMUNICATIONS ROOM, A, B..ETC X = PATCH PANEL IN THAT RACK OR CABINET 1-X YY = PORT ON THAT PANEL FROM 01-48
AutoCAD SHX Text GROUNDING NOTES: 1. ALL GROUNDING CONNECTION SHALL BE ROUTED TO CLOSEST GROUND BAR. 2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE CONNECTED TO EARTH & ELECTRICAL GROUNDING SYSTEM. SEE ELECTRICAL DETAILS FOR MORE INFORMATION. 3. ALL BONDING CONNECTIONS SHALL BE MADE WITH TWO HOLE CRIMP LUGS ONLY AT THE GROUND BAR. 4. GROUND CONNECTIONS SHALL BE MADE WITH A MINIMUM OF #10 AWG CABLE. 5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED SHALL BE SELF-LAMINATING. AAA = CABINET NUMBER BBB = POLE NUMBER CCCC = CAMERA NUMBER 3. INSTALL LABEL ON FRONT OF EACH PANEL
AutoCAD SHX Text NOTES: 1. INSTALL A WRAP-AROUND LABEL AT EACH END OF EACH CABLE. 2. WRAP-AROUND LABELS SHALL BE LASER-PRINTED AND BE SELF-LAMINATING. XXX = CABINET OR BUILDING. CAB/ADM IN EXAMPLE YYY = CABINET NUMBER OR BUILDING ABBREVIATION ZZ = FIBER STRAND COUNT AA = MULTIMODE MM OR SINGLEMODE SM
AutoCAD SHX Text NOTES: 1. INSTALL A PAPER LABEL BEHIND THE PLASTIC WINDOW IN STANDARD PLATES THAT ARE EQUIPPED WITH THE WINDOWS. 2. PROVIDE ADHESIVE LABELS ON WALL PHONE PLATES AND SURFACE MOUNT OUTLETS AND PLATES WITHOUT LABELING WINDOWS. DATA CABLE LABEL AA = COMMUNICATIONS ROOM, A, B..ETC X = PATCH PANEL IN THAT RACK OR CABINET 1-X YY = PORT ON THAT PANEL FROM 01-48
AutoCAD SHX Text CAMERA CABLING LABEL A-X-YY AA = COMMUNICATIONS ROOM, A, B..ETC X = PATCH PANEL IN THAT RACK OR CABINET 1-X YY = PORT ON THAT PANEL FROM 01-48
AutoCAD SHX Text
6-PORT PANEL IN CABINET
AutoCAD SHX Text
TYPICAL CRIMP LUG CONNECTIVITY
AutoCAD SHX Text
TYPICAL FOR EACH PIECE OF EQUIPMENT
AutoCAD SHX Text
ETHERNET SWITCH
AutoCAD SHX Text
CABINET
AutoCAD SHX Text
LIGHTNING ARRESTORS
AutoCAD SHX Text
ELEC. EQUIP.
AutoCAD SHX Text
CONNECT TO GROUND BAR
AutoCAD SHX Text
24 STRAND, OUTDOOR RATED, SINGLE-MODE FIBER CABLE
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DX024DSLX9KR
AutoCAD SHX Text
EXTERIOR RATED CAT-6A SHIELDED CABLE FOR ETHERNET CONNECTIVITY
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M59199
AutoCAD SHX Text
PLENUM RATED, GREEN, CAT-6 CABLE FOR ETHERNET CONNECTIVITY.
AutoCAD SHX Text
MOHAWK
AutoCAD SHX Text M58286
AutoCAD SHX Text
CAT-6 RATED PATCH CORD. FIELD VERIFY LENGTH.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text HC6GNxx
AutoCAD SHX Text
HDMI MALE TO MALE CABLE, LENGTH AS SHOWN. CONNECT PC TO PLATE.
AutoCAD SHX Text
LEGRAND
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
24 STRAND, SINGLEMODE FIBER CABLE. PLENUM RATED
AutoCAD SHX Text
OCC
AutoCAD SHX Text
DX024SSLX9YP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NETWORK SWITCH WITH 8 PoE PORTS. OUTDOOR AND WIDE TEMPERATURE RANGE. SHALL HAVE THE FIBER OPTIC MODULES TO CONNECT TO ADMIN SWITCH. EQUIP WITH ALL APPROPRIATE SFP MODULES REQUIRED FOR A FULLY OPERATIONAL SYSTEM. PROVIDE A POWER SUPPLY FOR EACH SWITCH TO ALLOW 60 PoE WATTS PER PORT
AutoCAD SHX Text
COMNET
AutoCAD SHX Text
CNGE11FX3TX8MSPOEHOK. INCLUDES POWER SUPPLY AND SFP MODULE
AutoCAD SHX Text CORE ETHERNET SWITCH. CONNECT TO FIBER BACKBONE AND SERVERS. EQUIP WITH PORTS AND SFP MODULES. 10 GIGABIT CONNECTIVITY TO ALL BUILDINGS AND SERVERS. 1 GIGABIT CONNECTIVITY TO ALL PERIMETER CABINETS.
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
C9300 SERIES C9300X-24Y
AutoCAD SHX Text ETHERNET SWITCH - IN A BUILDING FOR CONNECTIVITY TO CAMERAS AND USER PC'S. 48 COPPER PORTS POE+ WITH 10 GIGABIT SFP MODULE. VERIFY FIBER TYPE
AutoCAD SHX Text
CISCO
AutoCAD SHX Text
C9200 SERIES C9200L-48P-4X
AutoCAD SHX Text
60 (OR MORE AS REQUIRED) WATT SINGLE PORT POWER INJECTOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
NA
AutoCAD SHX Text
NB
AutoCAD SHX Text
NC
AutoCAD SHX Text
ND
AutoCAD SHX Text VIDEO SECURITY SERVER FOR ARCHIVING AND PROCESSING VIDEO. PROVIDE AND INSTALL A SERVER OR SERVERS WITH THE PROCESSING AND STORAGE TO MEET THE OWNERS NEED AS DETAILED ON THE DRAWINGS AND SPECS.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text GENETEC DIRECTORY SERVER. INSTALL AND CONNECT. THERE SHALL BE ONE DIRECTORY SERVER AND ONE FAILOVER DIRECTORY SERVER AT THE SITE.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text SECURITY MONITORING PC. FOUR (4) HDMI OUTPUTS. EQUIP WITH SOFTWARE THAT ALLOWS NETWORK CONNECTION TO THE NVR AND HAS ANY AND ALL SOFTWARE REQUIRED. TO CONFIGURE, REVIEW AND COPY/WRITE VIDEO TO A DVD WRITER. PC SHALL HAVE GRAPHICS CARD TO SUPPORT FOUR (4) HDMI CONNECTIONS.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text 27" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A TABLE TOP MOUNT AND ALL CABLING REQUIRED.
AutoCAD SHX Text
NEC
AutoCAD SHX Text
EA273WMI-BK
AutoCAD SHX Text
15" LAPTOP FOR VIEWING VIDEO AND MAINTAINING THE VIDEO SYSTEM. SEE SPECS.
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text 55" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS. PROVIDE A MONITOR MOUNT AND ALL CABLING REQUIRED.
AutoCAD SHX Text
NEC
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
LCD PULL-OUT MOUNT FOR LCD DISPLAY.
AutoCAD SHX Text
CHIEF
AutoCAD SHX Text
TS525TU
AutoCAD SHX Text
32" COMMERCIAL GRADE LCD MONITOR FOR VIDEO SECURITY CAMERAS.
AutoCAD SHX Text
NEC
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text PENDANT MOUNT FOR LCD DISPLAY. PROVIDE APPROVED COLUMNS, CEILING PLATES AND EQUIPMENT REQUIRED FOR MOUNTING
AutoCAD SHX Text
CHIEF
AutoCAD SHX Text
LCM1U
AutoCAD SHX Text
MINI MONITORING PC. PROVIDE PC AND MOUNT TO BACK OF LCD DISPLAY
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
WIRELESS KEYBOARD/MOUSE KIT
AutoCAD SHX Text
ORION
AutoCAD SHX Text
BCD-WS-KBM-W
AutoCAD SHX Text KVM SWITCH. SIZE AS REQUIRED FOR ALL ARCHIVE AND DIRECTORY SERVERS PLUS TWO SPARE SERVERS IN THE FUTURE. CONNECT ALL AND PROVIDE CABLING FOR THE TWO SPARE PORTS. LABEL KVM FOR EACH SERVER.
AutoCAD SHX Text
TRIPP LITE
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
SD
AutoCAD SHX Text
SC
AutoCAD SHX Text
SB
AutoCAD SHX Text
SA
AutoCAD SHX Text
SE
AutoCAD SHX Text
SF
AutoCAD SHX Text
SG
AutoCAD SHX Text
SH
AutoCAD SHX Text
SJ
AutoCAD SHX Text
SK
AutoCAD SHX Text THIS SYMBOL WITH A NUMBER INSIDE REFERS TO KEYNOTES. REFER TO NOTES ON THE SHEET FOR ADDITIONAL INFORMATION
AutoCAD SHX Text EQUIPMENT SCHEDULE. THIS SYMBOL WITH LETTERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.
AutoCAD SHX Text CABLE SCHEDULE. THIS SYMBOL WITH NUMBERS INSIDE REFERS EQUIPMENT SCHEDULES, SEE DETAILS AND EQUIPMENT SCHEDULES ON TC101, TC301, TC501 AND TC701.
AutoCAD SHX Text ACCESS CONTROL SYMBOL. "XX" IS LETTERS. SEE DETAILS ON TC5XX SHEETS FOR EQUIPMENT, CABLING AND RACEWAY DETAILS.
AutoCAD SHX Text SECURITY CAMERA. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.
AutoCAD SHX Text SECURITY CAMERA WITH 180 DEGREE VIEWING. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.
AutoCAD SHX Text SECURITY CAMERA WITH 360 DEGREE VIEWING, SINGLE-IMAGER. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.
AutoCAD SHX Text SECURITY CAMERA WITH 360 DEGREE VIEWING, MULTI-IMAGER. PROVIDE AND INSTALL A NEW SECURITY CAMERA. SEE DETAILS ON TC1XX SHEETS.
AutoCAD SHX Text EXISTING SECURITY CAMERA TO REMAIN. LEAVE IN PLACE AND CONFIGURE ON NEW VMS SYSTEM
AutoCAD SHX Text
EXISTING SECURITY CAMERA TO BE REMOVED AND REPLACED. CONFIGURE ON NEW VMS SYSTEM
AutoCAD SHX Text COMPUTER. PROVIDE AND INSTALL A PC FOR THE SECURITY SYSTEM. SEE DETAILS ON TC5XX SHEETS FOR REQUIREMENTS
AutoCAD SHX Text
CAMERA IDENTIFIER - CCC = SITE CODE - YY = BUILDING NUMBER/XX = CAMERA NUMBER
AutoCAD SHX Text
POLE IDENTIFIER - PL = POLE
AutoCAD SHX Text NEW CAMERA POLE - CONTRACTOR TO INSTALL NEW POLE AT THIS LOCATION TO SUPPORT NEW CAMERA LOCATION. SEE ELECTRICAL DRAWINGS.
AutoCAD SHX Text NEW PERIMETER NETWORK CABINET WITH FIBER CONNECTIVITY. CABINET PROVIDES LOCAL CONNECTIONS TO CAMERAS AND LIGHTING FOR CONTROL. REFER TO DETAILS FOR CABINET EQUIPMENT BUILD OUTS.
AutoCAD SHX Text MONITOR AND MOUNT LOCATION - REFER TO DETAILS FOR MOUNTING AND CABLING REQUIREMENTS.
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
XX
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text
CCC-YYXX
AutoCAD SHX Text
CAB-XXX
AutoCAD SHX Text P
AutoCAD SHX Text
LCD.XX"
AutoCAD SHX Text R
AutoCAD SHX Text 2-POST RACK:7'x19" BLACK RELAY RACK EQUIPPED WITH ONE FULL-LENGTH 6" VERTICAL ORGANIZER. RELAY RACK IS TO BE CONFIGURED WITH VERTICAL & HORIZONTAL CABLE LADDER AS SHOWN ON THE DRAWINGS AND AS DESCRIBED IN THE SPECS. EACH RACK SHALL BE CONFIGURED WITH ONE (1) 6" WIDE VERTICAL ORGANIZER WITH A COVER.
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text 4-POST ADJUSTABLE RACK. PUNCHED 3/8" HOLES. EQUIP WITH TWO 6" VERTICAL ORGANIZERS. SHALL HAVE STANDARD SCREW HOLES FOR MOUNTING 19" RACK COMPONENTS. EQUIP WITH CABLE LADDER AS PER SPECS AND DETAILS.
AutoCAD SHX Text
ORTRONICS
AutoCAD SHX Text
19-84-SSDA2132
AutoCAD SHX Text POWER STRIP, VERTICAL, FOR BACK OF EACH RACK. SALL HAVE (6) NEMA 5-20R RECEPTACLES AND SHALL BE 18" LONG. PLUG INTO WALL OUTLET. ATTACH THE POWER STRIP TO THE BACK OF THE VERTICAL CABLE LADDER OF EACH RACK.
AutoCAD SHX Text
HOFFMAN
AutoCAD SHX Text
DP1N160620S
AutoCAD SHX Text
SINGLE RACK UNIT PATCH CORD ORGANIZER (PCO-1) WITH HINGED COVER.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HS13C
AutoCAD SHX Text PATCH PANEL-24 PORT, EQUIPPED WITH 8-PIN MODULAR JACKS TO MATCH THE CABLE COLOR AND CABLE TYPE BEING TERMINATED. PROVIDE ONE MODULAR JACK FOR EACH CABLE BEING TERMINATED. SEE SPEC AND DRAWINGS FOR COLORS. EQUIP WITH REAR CABLE ORGANIZER
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
PANEL:HPJ24 ORGANIZER:ECMBR3
AutoCAD SHX Text RACK MOUNT FIBER PANEL. USE WHEN TERMINATING 24 OR LESS FIBER STRANDS. PROVIDE EACH FIBER PANEL WITH "SC" SIX OR 12 PACKS AS REQUIRED FOR TERMINATION OF ALL FIBERS. PROVIDE SPLICE TRAY AND SHELF FOR FUSION SPLICES TO PIGTAILS.
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
FPR3SP
AutoCAD SHX Text FIBER OPTIC CABLE STOWAGE RING. WALL MOUNTED. 12" OR 24". PROVIDE AND INSTALL TO SUPPORT BEND RADIUS REQUIREMENTS OF THE FIBER CABLE`
AutoCAD SHX Text
LEVITON
AutoCAD SHX Text
12" #48900-IFR / 24" #48900-OFR
AutoCAD SHX Text
WALL MOUNT FIBER OPTIC PATCH PANEL. PROVIDE LC TYPE CONNECTORS
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
FTU1SP
AutoCAD SHX Text
CAT-6 POE LIGHTNING ARRESTOR. INSTALL AND CONNECT TO GROUND WITH WIRE
AutoCAD SHX Text
RAYCAP
AutoCAD SHX Text
NJ2010B
AutoCAD SHX Text
SURFACE MOUNT BOX FOR NEW CABLES IN PERIMETER CABINET. SIZE AS REQUIRED
AutoCAD SHX Text
HUBBELL
AutoCAD SHX Text
HSB SERIES.
AutoCAD SHX Text
POE POWER INJECTOR
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text
SEE SPECS
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text H
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text J
AutoCAD SHX Text K
AutoCAD SHX Text L
AutoCAD SHX Text 2G
AutoCAD SHX Text
TWO-GANG BOX - PROVIDED BY EC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
AC
AutoCAD SHX Text ABOVE COUNTER - INSTALL BACKBOX SAME HEIGHT AS OTHER ELECTRICAL OUTLETS ABOVE THE COUNTER.
AutoCAD SHX Text
PBO
AutoCAD SHX Text
PROVIDED BY OTHERS
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
PCO-1
AutoCAD SHX Text
PATCH CORD ORGANIZER - 1 UNIT HIGH
AutoCAD SHX Text
AFG
AutoCAD SHX Text
ABOVE FINISHED GROUND
AutoCAD SHX Text
PCO-2
AutoCAD SHX Text
PATCH CORD ORGANIZER - 2 UNITS HIGH
AutoCAD SHX Text
AWG
AutoCAD SHX Text
AMERICAN WIRE GAUGE
AutoCAD SHX Text
PER
AutoCAD SHX Text
PROTECTED ENTRANCE TERMINAL
AutoCAD SHX Text
C-EMT
AutoCAD SHX Text
EMT TYPE CONDUIT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
QUANITY
AutoCAD SHX Text
EC
AutoCAD SHX Text
ELECTRICAL CONTRACTOR
AutoCAD SHX Text NOTES: 1. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURERS. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURERS. 2. PROVIDE AND INSTALL ALL APPROVED ANCHORS AND MOUNTING EQUIPMENT REQUIRED FOR PROVIDE AND INSTALL ALL APPROVED ANCHORS AND MOUNTING EQUIPMENT REQUIRED FOR MOUNTING. 3. INSTALL EQUIPMENT IN WEATHER PROOF BOX.INSTALL EQUIPMENT IN WEATHER PROOF BOX.
AutoCAD SHX Text
SL
AutoCAD SHX Text
SM
AutoCAD SHX Text
FIBER CABLE
AutoCAD SHX Text
CA
AutoCAD SHX Text
EXTERIOR 4K. POLE OR BUILDING MOUNTED
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-S2571LN
AutoCAD SHX Text
WV-QWL500-W
AutoCAD SHX Text
PACA4W ADD (WV-QWL500-W)
AutoCAD SHX Text
PAPM4W ADD (WV-QWL500-W)
AutoCAD SHX Text
EXTERIOR PTZ CAMERA. POLE OR BUILDING MOUNTED 30 X ZOOM MINIMUM
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-X6531N OR WV-X6533LN
AutoCAD SHX Text
WV-Q122A
AutoCAD SHX Text
PACA4GR ADD (WV-Q122A)
AutoCAD SHX Text
PAPM4GR ADD (WV-Q122A)
AutoCAD SHX Text
INDOOR AND OUTDOOR 360 FISHEYE SINGLE IMAGER 12 MEGAPIXEL
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-S4576LM
AutoCAD SHX Text
WV-QWL500-W
AutoCAD SHX Text
PACA4W ADD (WV-QWL500-W)
AutoCAD SHX Text
PAPM4W ADD (WV-QWL500-W)
AutoCAD SHX Text
INDOOR SHORT DISTANCE CAMERA. 2MP. DROP OR HARD CEILING
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-S2536LN
AutoCAD SHX Text
WV-QWL500-W
AutoCAD SHX Text
PACA4W ADD (WV-QWL500-W)
AutoCAD SHX Text
PAPM4W ADD (WV-QWL500-W)
AutoCAD SHX Text
INDOOR 5 MP DROP OR HARD CEILING
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-S2251L
AutoCAD SHX Text
WV-QWL500-W
AutoCAD SHX Text
PACA4W ADD (WV-QWL500-W)
AutoCAD SHX Text
PAPM4W ADD (WV-QWL500-W)
AutoCAD SHX Text
SEGREGATION CELL, VANDAL PROOF, CORNER MOUNT CAMERA. 1440 X 1080
AutoCAD SHX Text
AXIS
AutoCAD SHX Text
Q9216-SLV
AutoCAD SHX Text
OBSERVATION CELL CAMERA. ANTI-LIGATURE. CORNER MOUNT
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
FREEZER AND COOLER CAMERA. MULTI POINT PEN SIZE
AutoCAD SHX Text
AXIS
AutoCAD SHX Text
F-1035E CONTROL UNIT: F44
AutoCAD SHX Text
MULTI-HEAD CAMERA 270 DEGREES CORNER MOUNT
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
WV-X8571N
AutoCAD SHX Text
PWM850W
AutoCAD SHX Text
PACA4W ADD (PWM850W)
AutoCAD SHX Text
PAP4W ADD (PWM850W)
AutoCAD SHX Text
MULTI-HEAD CAMERA 360 DEGREES POLE MOUNT
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
WV-QWL500-W
AutoCAD SHX Text
WV-QCL101-W [*2] ADD (PS485W)
AutoCAD SHX Text
INDOOR PTZ CAMERA. VISITING ROOM. DROP OR HARD CEILING
AutoCAD SHX Text
PANASONIC
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
CB
AutoCAD SHX Text
CC
AutoCAD SHX Text
CD
AutoCAD SHX Text
CE
AutoCAD SHX Text
CF
AutoCAD SHX Text
CG
AutoCAD SHX Text
CH
AutoCAD SHX Text
CJ
AutoCAD SHX Text
CK
AutoCAD SHX Text
CL
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/21301.JBB
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text acctg template.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472AMFMaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_24B
AutoCAD SHX Text sheet title
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text
VIDEO MANAGEMENT SYSTEM UPGRADE- PHASE 1
AutoCAD SHX Text
BARAGA CORRECTIONAL FACILITY
AutoCAD SHX Text
BARAGA, MICHIGAN
AutoCAD SHX Text
YXXXX
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text 11/19/21
AutoCAD SHX Text
50%%% OWNER REVEIW
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text 1/24/22
AutoCAD SHX Text
90%%% OWNER REVIEW
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. GRAND RIVER AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text 3/7/22
AutoCAD SHX Text
97%%% OWNER REVIEW
AutoCAD SHX Text 4/15/22
AutoCAD SHX Text
ISSUE FOR BID
TC102
SECURITY CAMERA
CONNECTIVITY CODE
TC102
SECURITY CAMERA
CONNECTIVITY CODE
TC102
NEW PC AND MONITOR
FOR CAMERA SYSTEM
TC102
CONNECTIVITY CODE
TC102
CONNECTIVITY CODE
TC102
CONNECTIVITY CODE
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
P2
P4
P6
P8
P1
P3
P5
100/1000 SFP
P10 Link/ActiveP9
Console
FAULT
9600.N.8.1
PWR2
PWR1
R.M.
PWR
Communication Networks
TM
www.comnet.net 203-796-5300
P7
10/100/1000T
100/1000 SFP
10/100/1000T
P9
P10
P7 P8 P5 P6 P3 P4 P1 P2
PoE
MEAN WELLDRP-240-48
SWITCHING REGULATOR
POWER FACTOR CORRECTION
INPUT: 100-240VAC 3.5A
OUTPUT: 48V 5.0A
MADE IN TAIWAN
LN-V-V+V+V
DC OK
CNGE2FE8MSPOE
P2
P4
P6
P8
P1
P3
P5
100/1000 SFP
P10 Link/ActiveP9
Console
FAULT
9600.N.8.1
PWR2
PWR1
R.M.
PWR
Communication Networks
TM
www.comnet.net 203-796-5300
P7
10/100/1000T
100/1000 SFP
10/100/1000T
P9
P10
P7 P8 P5 P6 P3 P4 P1 P2
PoE
MEAN WELLDRP-240-48
SWITCHING REGULATOR
POWER FACTOR CORRECTION
INPUT: 100-240VAC 3.5A
OUTPUT: 48V 5.0A
MADE IN TAIWAN
LN-V-V+V+V
DC OK
TC102
NETWORK CABINET DETAIL
TYPICAL FOR PERIMETER CABINETS 4
TC102
WALLFIELD BUILD-OUT FOR CAMS ON POLES
THAT ARE FED FROM A BUILDING
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
TC102
NEW PC FOR CAMERA SYSTEM
REPLACE EXISTING
PC-MINI-NEW
PC-MINI-REP
PC-NEW
PC-REP
TC102
CABLING DETAILS
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
DATA
AutoCAD SHX Text
BLANK
AutoCAD SHX Text
SC
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
%%UABOVE DROP CEILING INSTALLATION
AutoCAD SHX Text
%%UOPEN CEILING INSTALLATION
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB1OW SURFACE BOX HUBBELL HSB1OW HUBBELL HSB1OW HSB1OW 1 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 1 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text
%%UEXTERIOR CAMERA CABLING
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB2OW SURFACE BOX HUBBELL HSB2OW HUBBELL HSB2OW HSB2OW 2 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 2 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text INSTALLATION NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING.
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 SURFACE BOX HUBBELL HSB4OW SURFACE BOX HUBBELL HSB4OW HUBBELL HSB4OW HSB4OW 3 CAT-6 CABLES-GREEN MOHAWK M58286 CAT-6 CABLES-GREEN MOHAWK M58286 MOHAWK M58286 M58286 3 CAT-6 JACK HUBBELL HXJ6GNCAT-6 JACK HUBBELL HXJ6GNHUBBELL HXJ6GNHXJ6GN
AutoCAD SHX Text
EXTERIOR CAMERA ON WALL
AutoCAD SHX Text
15' CABLE SERVICE LOOP. SUPPORT TO STRUCTURE
AutoCAD SHX Text
CAT-6 CABLE TO COMM RM.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
15' CABLE SERVICE LOOP. SUPPORT TO STRUCTURE
AutoCAD SHX Text
CAT-6 CABLE TO COMM RM.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
15' CABLE SERVICE LOOP. SUPPORT TO STRUCTURE
AutoCAD SHX Text
EXTERIOR CAMERA ON WALL
AutoCAD SHX Text
15' CABLE SERVICE LOOP. SUPPORT TO STRUCTURE
AutoCAD SHX Text
CAT-6 CABLE TO COMM RM.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
EXTERIOR CAMERA ON WALL
AutoCAD SHX Text
15' CABLE SERVICE LOOP. SUPPORT TO STRUCTURE
AutoCAD SHX Text
CAT-6 CABLE TO COMM RM.
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text PARTS CONNECTIVITY CODE CONNECTIVITY CODE QTY DESCRIPTION MANUFACTURER PART # DESCRIPTION MANUFACTURER PART # MANUFACTURER PART # PART # 1 GFI PLATE-STAINLESS HUBBELL SS26 GFI PLATE-STAINLESS HUBBELL SS26 HUBBELL SS26 SS26 2 CAT-6 CABLE MOHAWK M58281 CAT-6 CABLE MOHAWK M58281 MOHAWK M58281 M58281 2 CAT-6 JACK HUBBELL HXJ6OW CAT-6 JACK HUBBELL HXJ6OW HUBBELL HXJ6OW HXJ6OW 1 TWO HOLE GFI PLATE HUBBELL ISF2GYTWO HOLE GFI PLATE HUBBELL ISF2GYHUBBELL ISF2GYISF2GY
AutoCAD SHX Text
DATA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
DATA
AutoCAD SHX Text
LABEL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NOTES: 1. PROVIDE A SURFACE MOUNT BOX TO THE BUILDING PROVIDE A SURFACE MOUNT BOX TO THE BUILDING STRUCTURE NEAR THE SECURITY CAMERA LOCATION. 2. HEIGHT IS AT 18" UNLESS OTHERWISE NOTED ON THE HEIGHT IS AT 18" UNLESS OTHERWISE NOTED ON THE PLANS. 3. SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL SEE CEILING PLAN FOR INSTALLATION. EC TO INSTALL CONDUIT FOR LOCATIONS WHERE THE CAMERA IS IN AN OPEN CEILING. 4. USE ONLY SECURITY SCREWS WITH THESE PLATES. USE ONLY SECURITY SCREWS WITH THESE PLATES. 5. LABEL THE FACEPLATE WITH A LASER PRINTED LABELLABEL THE FACEPLATE WITH A LASER PRINTED LABEL
AutoCAD SHX Text 1" CONDUIT WITH A NYLON BUSHING. STUB TO: ABOVE DROP CEILING OR TO BOTTOM OF STRUCTURAL STEEL IN OPEN CEILING AREA TO AN ACCESSIBLE CEILING AREA
AutoCAD SHX Text
1-GANG BACKBOX HUBBELL-BELL #5387-0
AutoCAD SHX Text
EXISTING GREEN CAT-6 PATCH CABLE
AutoCAD SHX Text NOTES: 1. INSTALL A NEW PC TO THIS LOCATION. SEE FLOORPLANS. INSTALL A NEW PC TO THIS LOCATION. SEE FLOORPLANS. 2. ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO CALL IF THERE IS AN ISSUE WITH THE PC. SEE DESIGNER FOR STICKER. 3. PROVIDE AND INSTALL A MONITOR AND KEYBOARD/MOUSE PROVIDE AND INSTALL A MONITOR AND KEYBOARD/MOUSE 4. CONNECT PC TO THE LCD AND KEYBOARD/MOUSE. CONNECT PC TO THE LCD AND KEYBOARD/MOUSE. 5. SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITYSETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY
AutoCAD SHX Text
NEW DESKTOP MONITOR
AutoCAD SHX Text
EXISTING CAMERA NETWORK FACEPLATE
AutoCAD SHX Text
SC
AutoCAD SHX Text
GREEN CAT-6 PATCH CABLE
AutoCAD SHX Text NOTES: 1. INSTALL A NEW PC TO THIS LOCATION. SEE FLOORPLANS. INSTALL A NEW PC TO THIS LOCATION. SEE FLOORPLANS. 2. REMOVE EXISTING PC AND PROVIDE TO THE OWNER AT THEIR REMOVE EXISTING PC AND PROVIDE TO THE OWNER AT THEIR LOCATION. 3. ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO CALL IF THERE IS AN ISSUE WITH THE PC. SEE DESIGNER FOR STICKER. 4. CONNECT PC TO THE LCD AND KEYBOARD/MOUSE. IF THERE CONNECT PC TO THE LCD AND KEYBOARD/MOUSE. IF THERE ARE MULTIPLE LCD'S, CONNECT TO ALL EXISTING LCD'S 5. PROVIDE REMOVED PC TO THE OWNER AT THEIR DESIGNATED PROVIDE REMOVED PC TO THE OWNER AT THEIR DESIGNATED WAREHOUSE. 6. SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITYSETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY
AutoCAD SHX Text
CAMERA NETWORK FACEPLATE
AutoCAD SHX Text
DESKTOP MONITOR
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
%%UFRONT VIEW
AutoCAD SHX Text
MOUNTING POLE
AutoCAD SHX Text
TYPICAL COMM CONDUITS
AutoCAD SHX Text
TO LIGHT POLES AND
AutoCAD SHX Text
OTHER CABINETS
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text
NA
AutoCAD SHX Text
EXISTING MODULAR JACKS IN SURFACE MOUNT BOX.
AutoCAD SHX Text
MODULAR JACKS IN SURFACE MOUNT BOX. TERMINATE ALL NEW CABLES HERE FOR TESTING
AutoCAD SHX Text
CAT-6 PATCH (TYP)
AutoCAD SHX Text KEYED NOTES: PROVIDE ONE (1) SURGE SUPPRESSOR FOR EACH CAT-6 CABLE THAT IS FED INTO THE CABINET, NEW AND EXISTING. CONNECT TO GROUND BAR. ENSURE DIRECTION OF ARRESTOR IS CORRECT. SEE ONE LINE FOR QUANTITY OF EXISTING CAMERAS AND NEW CAMERAS AT EACH CABINET. CONNECT NEW SHIELDED CABLES AND LIGHTNING SUPPRESSORS TO THE GROUND BAR. ONE CONNECTION FOR EACH. INSTALL NEW POE INJECTORS FOR EACH PTZ CAMERA. REMOVE EXISTING AND PROVIDE TO THE OWNER. MOUNT TO CABINET AND CONNECT TO POWER. PROVIDE PATCH CABLES TO CONNECT CAMERAS TO ETHERNET SWITCH PROVIDE NEW ETHERNET SWITCH AND SFP MODULE FOR SWITCH. CONNECT TO FIBER BACKBONE AND CORE SWITCH IN ADMIN BUILDING. PROVIDE EXISTING SWITCH TO THE OWNER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. CABINETS ARE EXISTING AT PERIMETER OF SITE. SEE SITE CABINETS ARE EXISTING AT PERIMETER OF SITE. SEE SITE PLANS FOR LOCATIONS 2. SEE SITE PLANS AND CAMERA ONE-LINE FOR LOCATIONS SEE SITE PLANS AND CAMERA ONE-LINE FOR LOCATIONS WHERE NEW CAMERAS AND CAMERA CABLES ARE TO BE INSTALLED. 3. REPLACE ALL THE EXISTING LIGHTNING ARRESTORS. CONNECT REPLACE ALL THE EXISTING LIGHTNING ARRESTORS. CONNECT TO NEW AND EXISTING MODULAR JACKS. 4. DRESS ALL CABLING WHEN ROUTING WITHIN CABINET. UTILIZE DRESS ALL CABLING WHEN ROUTING WITHIN CABINET. UTILIZE WIRE DUCT WHENEVER POSSIBLE. 5. AT NO TIME SHALL PROTECTED, UNPROTECTED AND POWER AT NO TIME SHALL PROTECTED, UNPROTECTED AND POWER CABLES COME IN CONTACT WITH EACH OTHER. MAINTAIN SEPARATION BETWEEN 300 AND 600 VOLT RATED CABLES. 6. REFER TO ELECTRICAL DRAWINGS AND/OR SPECIFICATIONS REFER TO ELECTRICAL DRAWINGS AND/OR SPECIFICATIONS FOR ADDITIONAL CONDUIT AND CABINET REQUIREMENTS.
AutoCAD SHX Text
ETHERNET SWITCH
AutoCAD SHX Text
POWER SUPPLY FOR ENET SWITCH -TO REMAIN
AutoCAD SHX Text
CAT-6 PATCH CABLES (TYP)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FUTURE SWITCH
AutoCAD SHX Text
FIBER OPTIC PATCH CABLE
AutoCAD SHX Text
PLUG STRIP -EXIST
AutoCAD SHX Text J
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL NEW SURGE SUPPRESSOR/ LIGHTNING ARRESTOR
AutoCAD SHX Text
GROUND BAR-EXIST
AutoCAD SHX Text
EXISTING FIBER OPTIC PATCH PANEL
AutoCAD SHX Text
RESERVED FOR ELECTRICAL
AutoCAD SHX Text K
AutoCAD SHX Text
CAT-6 CABLES TO NEW CAMERAS AT PERIMETER. SEE CAMERA ONE-LINE FOR QTY
AutoCAD SHX Text
AutoCAD SHX Text
POE INJECTORS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UFRONT VIEW
AutoCAD SHX Text J
AutoCAD SHX Text
GROUND BAR
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
ND
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
EXISTING SHELF ON WALL
AutoCAD SHX Text KEYED NOTES: PLYWOOD WALLFIELD IS EXISTING UNLESS NOTED ON THE FLOORPLANS TO INSTALL A NEW ONE. WHERE REQUIRED, INSTALL A 4' X 4' X 3/4" FIRE-RATED PLYWOOD. CONFIRM LOCATION WITH OWNER AND ENGINEER BEFORE INSTALLATION. PROVIDE ONE (1) SURGE SUPPRESSOR FOR EACH CAT-6 CABLE THAT IS FED INTO THE BUILDING FROM OUTSIDE THE BUILDING'S "CONE OF PROTECTION". REPLACE EXISTING SURGE SUPPRESSORS. CONNECT NEW SHIELDED CABLES AND LIGHTNING SUPPRESSORS TO THE GROUND BAR. ONE CONNECTION FOR EACH. INSTALL NEW POE INJECTORS FOR EACH PTZ CAMERA. REMOVE EXISTING AND PROVIDE TO THE OWNER. MOUNT TO CABINET AND CONNECT TO POWER. PROVIDE PATCH CABLES TO CONNECT CAMERAS TO ETHERNET SWITCH SEE FLOORPLANS AND SITE PLANS FOR NEW CABLING REQUIRED FOR NEW CAMERAS. INSTALL CABLE FROM CAMERA TO WALLFIELD AND FROM WALLFIELD TO COMM ROOM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. WALLFIELD EXISTS UNLESS SPECIFICALLY NOTED TO INSTALL A WALLFIELD EXISTS UNLESS SPECIFICALLY NOTED TO INSTALL A NEW ONE. SEE FLOORPLANS FOR NOTES ON NEW WALLFIELDS. ALL EQUIPMENT SHALL BE SECURELY MOUNTED TO THE WALLFIELD. 2. ANY NEW CABLES SHALL BE TERMINATED ONTO MODULAR ANY NEW CABLES SHALL BE TERMINATED ONTO MODULAR JACKS AND INTO SURFACE MOUNT BOXES. SEE CAMERA ONE LINE TO SEE WHERE NEW CAMERAS AND CABLES ARE TO BE INSTALLED 3. AT NO TIME SHALL UNPROTECTED AND PROTECTED CABLES AT NO TIME SHALL UNPROTECTED AND PROTECTED CABLES COME IN CONTACT WITH EACH OTHER. 4. WHERE OUTDOOR CAT-6 CABLES ROUTE THROUGH A BUILDING WHERE OUTDOOR CAT-6 CABLES ROUTE THROUGH A BUILDING THEY SHALL BE INSTALLED INSIDE CONDUIT. 5. LABEL ALL POWER INJECTORS FOR THE CAMERA THEY LABEL ALL POWER INJECTORS FOR THE CAMERA THEY CONNECT TO.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONNECT TO UPS
AutoCAD SHX Text
SURGE SUPPRESSOR, LIGHTNING ARRESTOR
AutoCAD SHX Text
AutoCAD SHX Text
2'X2' FIREPROOF PLYWOOD WALLFIELD
AutoCAD SHX Text
CAT-6 CABLE TO PATCH PANEL IN RACK (TYP)
AutoCAD SHX Text
TYPICAL COMM CONDUITS TO LIGHT POLES AND OTHER CABINETS
AutoCAD SHX Text
CAT-6 CABLES TO CAMERAS TYPICAL
AutoCAD SHX Text
HIGH POWER POE INJECTORS FOR PTZ CAMS
AutoCAD SHX Text
INSTALL NEW UPS. SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
CAT-6 PATCH CABLES
AutoCAD SHX Text
CAT-6 CABLES FROM PANEL IN COMM ROOM.
AutoCAD SHX Text
EXISTING PLUG STRIP
AutoCAD SHX Text
INSTALL D-RINGS WHERE REQUIRED
AutoCAD SHX Text K
AutoCAD SHX Text
EXISTING POWER OUTLET
AutoCAD SHX Text
EXISTING MODULAR JACKS IN SURFACE MOUNT BOX.
AutoCAD SHX Text
AutoCAD SHX Text
POE INJECTORS
AutoCAD SHX Text
EXISTING CAT-6 CABLES TO CAMERAS
AutoCAD SHX Text
NEW CAT-6 CABLES TO CAMERAS. SEE CAMERA ONE-LINE AND SITE PLAN FOR QTY.
AutoCAD SHX Text K
AutoCAD SHX Text
MODULAR JACKS IN SURFACE MOUNT BOX. TERMINATE ALL NEW CABLES HERE FOR TESTING
AutoCAD SHX Text
MODULAR JACKS IN SURFACE MOUNT BOX. TERMINATE ALL NEW CABLES HERE FOR TESTING
AutoCAD SHX Text
NEW CAT-6 CABLES TO CAMERAS. SEE CAMERA ONE-LINE AND SITE PLAN FOR QTY.
AutoCAD SHX Text
CONNECT POWER INJECTORS TO POWER STRIP
AutoCAD SHX Text
EXISTING LCD AND MOUNT
AutoCAD SHX Text NOTES: 1. INSTALL A NEW MINI PC TO THIS LOCATION. SEE INSTALL A NEW MINI PC TO THIS LOCATION. SEE FLOORPLANS. 2. REMOVE EXISTING PC AND PROVIDE TO THE OWNER AT THEIR REMOVE EXISTING PC AND PROVIDE TO THE OWNER AT THEIR LOCATION. 3. ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO CALL IF THERE IS AN ISSUE WITH THE PC. SEE DESIGNER FOR STICKER. 4. CONNECT PC TO THE LCD AND WIRELESS KEYBOARD/MOUSE. CONNECT PC TO THE LCD AND WIRELESS KEYBOARD/MOUSE. 5. PROVIDE REMOVED PC TO THE OWNER AT THEIR DESIGNATED PROVIDE REMOVED PC TO THE OWNER AT THEIR DESIGNATED WAREHOUSE. 6. SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY 7. SETUP CAMERAS THE OWNER WISHES TO VIEW. PROVIDE SETUP CAMERAS THE OWNER WISHES TO VIEW. PROVIDE KEYBOARD AND MOUSE TO OWNER IN ADMIN BUILDING
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
PROVIDE NEW WIRELESS KEYBOARD AND MOUSE
AutoCAD SHX Text NOTES: 1. INSTALL A NEW MINI PC TO THIS LOCATION. SEE INSTALL A NEW MINI PC TO THIS LOCATION. SEE FLOORPLANS. 2. INSTALL NEW LCD AND PENDANT MOUNT. SUPPORT FROM INSTALL NEW LCD AND PENDANT MOUNT. SUPPORT FROM BUILDING STRUCTURE. BOTTOM OF LCD SHALL BE AT 7' AFF. 3. ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO ADD AN ORANGE STICKER TO THE PC THAT DETAILS WHO TO CALL IF THERE IS AN ISSUE WITH THE PC. SEE DESIGNER FOR STICKER. 4. CONNECT PC TO THE LCD AND WIRELESS KEYBOARD/MOUSE. CONNECT PC TO THE LCD AND WIRELESS KEYBOARD/MOUSE. 5. SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY SETUP ON THE GENETEC SYSTEM AND TEST CONNECTIVITY 6. SETUP CAMERAS THEY OWNER WISHES TO VIEW. PROVIDE SETUP CAMERAS THEY OWNER WISHES TO VIEW. PROVIDE KEYBOARD AND MOUSE TO OWNER IN ADMIN BUILDING
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
PROVIDE NEW WIRELESS KEYBOARD AND MOUSE
AutoCAD SHX Text
ATTACH MINI PC TO BACK OF LCD. PROVIDE MOUNTING HARDWARE
AutoCAD SHX Text
SJ
AutoCAD SHX Text
NEW LCD AND MOUNT
AutoCAD SHX Text
ATTACH MINI PC TO BACK OF LCD. PROVIDE MOUNTING HARDWARE
AutoCAD SHX Text
SH
AutoCAD SHX Text
SK
AutoCAD SHX Text
SK
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text
SL
AutoCAD SHX Text
SJ
AutoCAD SHX Text
SH
AutoCAD SHX Text
SL
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/21301.JBB
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text acctg template.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472AMFMaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_24B
AutoCAD SHX Text sheet title
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text
VIDEO MANAGEMENT SYSTEM UPGRADE- PHASE 1
AutoCAD SHX Text
BARAGA CORRECTIONAL FACILITY
AutoCAD SHX Text
BARAGA, MICHIGAN
AutoCAD SHX Text
YXXXX
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text 11/19/21
AutoCAD SHX Text
50%%% OWNER REVEIW
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text 1/24/22
AutoCAD SHX Text
90%%% OWNER REVIEW
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. GRAND RIVER AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text 3/7/22
AutoCAD SHX Text
97%%% OWNER REVIEW
AutoCAD SHX Text 4/15/22
TC103
CAMERA POLE MOUNTING DETAIL
TC103
INTERIOR CORNER MOUNT CAMERA
RACEWAY & SEALANT DETAIL
TC103
PARAPET MOUNT
CAMERA INSTALLATION 3
TC103
HARD CEILING MOUNT CAMERA
RACEWAY & SEALANT DETAIL
TC103
TYPICAL OPEN-CEILING (PENDANT)
CAMERA INSTALLATION
TC103
TYPICAL DRYWALL OR DROP-CEILING
CAMERA INSTALLATION9
TC103
TYPICAL INTERIOR WALL/CEILING MOUNT
CAMERA INSTALLATION
TC103
EXTERIOR CORNER, WALL MOUNT
CAMERA INSTALLATION 2
TC103
CAMERA THROUGH WALL
RACEWAY & SEALANT DETAIL
TC103
TYPICAL DRYWALL OR DROP-CEILING
CAMERA INSTALLATION
TC103
BARAGA SECURITY
MOUNTING DETAILS
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
AutoCAD SHX Text
%%UMETAL & WOOD POLES
AutoCAD SHX Text
16' AFG MINIMUM OR 2' ABOVE RAZORWIRE MINIMUM
AutoCAD SHX Text
SEE ELECTRICAL DRAWINGS FOR ACTUAL CONDUIT REQUIREMENTS AND ROUTING
AutoCAD SHX Text
22' AFG MINIMUM
AutoCAD SHX Text
PTZ CAMERA HEIGHT
AutoCAD SHX Text
FIXED CAMERA HEIGHT
AutoCAD SHX Text
STUB TO ACCESSIBLE CEILING
AutoCAD SHX Text
CAT-6 CABLE
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text NOTES: 1. ALL CAMERAS AND HARDWARE SHALL BE INSTALLED WITH ALL CAMERAS AND HARDWARE SHALL BE INSTALLED WITH SECURE SCREWS 2. INSTALL PATCH CORD FROM CAT-6 CONNECTOR TO CAMERA. INSTALL PATCH CORD FROM CAT-6 CONNECTOR TO CAMERA. 3. INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW THE DROP CEILING. 4. CONTRACTOR SHALL PROVIDE BRACKETS TO POSITION CAMERA CONTRACTOR SHALL PROVIDE BRACKETS TO POSITION CAMERA INSIDE CORNER MOUNT. 5. POSITION CAMERA TO COVER ENTIRE AREA OF THE CELL.POSITION CAMERA TO COVER ENTIRE AREA OF THE CELL.
AutoCAD SHX Text
INTERIOR CORNER MOUNT
AutoCAD SHX Text
SECURITY CAMERA
AutoCAD SHX Text
WALL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
OVERHANG PARAPET MOUNT
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text NOTES: 1. CORE THRU WALL TO CONNECT THE CONDUIT TO A BACKBOX. CORE THRU WALL TO CONNECT THE CONDUIT TO A BACKBOX. 2. ATTACH THE CAMERA MOUNT TO THE WALL. ATTACH THE CAMERA MOUNT TO THE WALL. 3. PROVIDE A DRIP LOOP ON THE CABLES AS THEY ROUTE FROM THE MOUNT TO THE BACKBOX. PROVIDE A DRIP LOOP ON THE CABLES AS THEY ROUTE FROM THE MOUNT TO THE BACKBOX. 4. ALL CAMERAS AND HARDWARE SHALL BE INSTALLED WITH APPROVED ANCHORS.ALL CAMERAS AND HARDWARE SHALL BE INSTALLED WITH APPROVED ANCHORS.
AutoCAD SHX Text
WEATHERPROOF SURFACE-MOUNT BACKBOX
AutoCAD SHX Text
PARAPET MOUNT
AutoCAD SHX Text
VIDEO & CONTROL & POWER CABLE
AutoCAD SHX Text INSTALL A 3/4" CONDUIT THROUGH THE WALL AT LOCATION REQUIRED FOR PROPER CAMERA INSTALLATION. COORDINATE HEIGHT WITH OWNER PRIOR TO INSTALLATION.
AutoCAD SHX Text NOTES: 1. INSTALL PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. INSTALL PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. 2. INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW THE CEILING. INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW THE CEILING. 3. ALL CAMERAS SHALL BE INSTALLED WITH APPROVED ANCHORS. ALL CAMERAS SHALL BE INSTALLED WITH APPROVED ANCHORS. 4. WHERE CAMERA BACKBOX IS NOT LARGE ENOUGH FOR CAT-6 CONNECTOR THE CONTRACTOR SHALL WHERE CAMERA BACKBOX IS NOT LARGE ENOUGH FOR CAT-6 CONNECTOR THE CONTRACTOR SHALL PROVIDE A BACKBOX NEXT TO CAMERA FOR CONNECTION OF CAT-6 JACK.
AutoCAD SHX Text
HARD CEILING
AutoCAD SHX Text
RACEWAY OR CONDUIT
AutoCAD SHX Text
CAMERA
AutoCAD SHX Text
STUB TO ACCESSIBLE CEILING
AutoCAD SHX Text
SINGLE GANG BACKBOX FOR 8-PIN CAT-6 MODULAR JACK
AutoCAD SHX Text
4" SQUARE DEEP BACKBOX
AutoCAD SHX Text
USE IN LOCATION WHERE SIGHT LINES REQUIRE.
AutoCAD SHX Text
OR
AutoCAD SHX Text KEYED NOTES: PROVIDE ONE (1) SURGE SUPPRESSOR FOR EACH CAT-6 CABLE AT EACH POLE. INSTALL INSIIDE A NEW JUCNTION BOX. CONNECT TO GROUND AT THE POLE. SEE ELECTRICAL DRAWINSG FOR DETAILS. VERIFY HEIGHT ON THE POLE FOR THE NEW CAMERAS WITH THE OWNER PRIOR TO CONDUIT AND CAMERA INSTALALTION. ALL CAMERAS SHALL BE HIGH ENOUGH TO SEE OVER THE FENCE. SECURE JUNCTION BOX, CAMERA MOUNT AND CONDUIT TO THE POLE WITH METAL STRAPS. ENSURE THEY DO NOT BREAK IN WARM WEATHER. THIS HAS HAPPENED TO STRAPS THAT WERE TOO TIGHT OR DID NOT HAVE A RUBBER STRIP BETWEEN THE POLE AND STRAP.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: 1. POLE EXISTS. CAMERA MAY ALREADY BE INSTALLED. SEE SITE POLE EXISTS. CAMERA MAY ALREADY BE INSTALLED. SEE SITE PLAN. INSTALL NEW CAMERAS WHERE SHOWN ON SITE PLAN OR CAMERA ONE LINE. 2. WHEN INSTALLING A NEW CAMERA INSTALL CONDUIT FROM WHEN INSTALLING A NEW CAMERA INSTALL CONDUIT FROM THE PERIMETER CABINET TO THE POLE. SEE ELECTRICAL FOR SPECIFICS. 3. INSTALL JUNCTION BOX AT BOTTOM OF POLE FOR INSTALL JUNCTION BOX AT BOTTOM OF POLE FOR TERMINATION OF CABLE AND INSTALLATION OF LIGHTNING ARRESTOR. SEE ELECTRICAL FOR BOX SIZE. 4. WHERE NO JUNCTION BOX IS EXISTING AT THE BOTTOM OF WHERE NO JUNCTION BOX IS EXISTING AT THE BOTTOM OF THE POLE, INSTALL A JUNCTION BOX. BACKPULL CABLE TO THE NEW JUNCTION BOX FROM THE CAMERA. TERMINATE AND TEST AND LABEL CABLE. 5. INSTALL CONDUIT AND PATCH CABLE FROM JUNCTION BOX TO INSTALL CONDUIT AND PATCH CABLE FROM JUNCTION BOX TO THE CAMERA. CONNECT CAMERA AND TEST. 6. SEE ELECTRICAL DIAGRAMS FOR GROUNDING OF LIGHTNING SEE ELECTRICAL DIAGRAMS FOR GROUNDING OF LIGHTNING ARRESTOR. 7. INSTALL CONDUIT FROM JUNCTION BOX TO CAMERA BOX FOR INSTALL CONDUIT FROM JUNCTION BOX TO CAMERA BOX FOR NEW CAMERA LOCATIONS.
AutoCAD SHX Text
POLE BASE
AutoCAD SHX Text
CONDUIT TO PERIMETER CABINET
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
CONDUIT
AutoCAD SHX Text NOTES: 1. INSTALL CAMERA IN A PENDANT MOUNT SUPPORTED BY CONDUIT TO THE DECK INSTALL CAMERA IN A PENDANT MOUNT SUPPORTED BY CONDUIT TO THE DECK OR STRUCTURE. 2. INSTALL THE PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE INSTALL THE PATCH CABLE FROM CAT-6 CONNECTOR TO CAMERA. SHALL BE PLENUM RATED. 3. INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW.INSTALL A LABEL ON THE CAMERA THAT IS VISIBLE FROM BELOW.
AutoCAD SHX Text
TYPICAL INSTALLATION FOR INTERIOR CAMERA IN AN OPEN CEILING PENDANT MOUNT
AutoCAD SHX Text
CONFIRM CAMERA HEIGHT WITH DESIGNER PRIOR TO INSTALLATION
AutoCAD SHX Text
CONDUIT EXTENSION COLUMN, CUSTOM LENGTH
AutoCAD SHX Text
DOUBLE GANG BOX
AutoCAD SHX Text
CAT-6 CONNECTOR
AutoCAD SHX Text
CAT-6 CAMERA CABLE
AutoCAD SHX Text
CAT-6 PATCH CABLE
AutoCAD SHX Text NOTES: 1. INSTALL CAMERAS RECESSED IN DROP CEILING OR DRYWALL CEILING.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .