This file consists of detailed architectural and engineering plans for the Baraga Correctional Facility Video Management System Upgrade—Phase 1, a project undertaken by the State of Michigan Department of Technology, Management and Budget. The project involves the installation of a comprehensive video security system upgrade across multiple buildings at the 13924 Wadaga Road facility in Baraga, Michigan. The scope of work includes the design and installation of new security camera infrastructure, data cabling, fiber optic backbone connectivity, electrical power systems, and uninterruptible power supply (UPS) equipment. The plans cover seven housing units, an administrative building, an education building, a support services building, and a warehouse facility, with both existing condition floor plans and new installation diagrams provided for each structure. Matrix Consulting Engineers, Inc. served as the electrical engineer, while CommTech Design provided security system design. The project drawings were issued for bid on April 1, 2022, following 50%, 90%, and 97% owner review phases completed in November 2021, January 2022, and March 2022 respectively.
The project specifications detail two primary UPS installations: a 20 kilovolt-ampere system for the administrative building with a Liebert EXM unit and 13-minute battery runtime, and multiple 1.5 kilovolt-ampere rack-mounted units for distributed camera equipment backup power across facility locations. Electrical work includes new 20 kilovolt-ampere step-up transformers, conduit installation requirements specifying minimum three-quarter-inch trade size with defined strap distances based on height, and comprehensive grounding and surge protection for all exterior camera installations. The plans mandate field verification by contractors prior to work commencement, surface mounting of conduit where walls cannot be fished, and completion of electrical outages within two-hour windows with portable generator backup for extended disruptions. All wall and floor penetrations must be sealed to maintain original ratings, and relocated lighting and camera equipment requires functional verification before contractor departure from the site.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Plans 3 of 4 21301.pdf | ||
| Plans 4 of 4 21301.pdf | ||
| Addendum 1 21301.pdf | ||
| LEIN form 21301.pdf | ||
| Addendum 2 21301.pdf | ||
| Plans 2 of 4 21301.pdf | ||
| Specification 21301.pdf | ||
| Advertisement 21301.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING LIST:
TC101 SECURITY LEGENDS DETAILS AND SCHEDULES
TC102 DATA CABLING AND SECURITY MOUNTING DETAILS
TC103 SECURITY MOUNTING DETAILS
TC104 BARAGA PERIMETER CAMERA CONNECTIVITY DIAGRAM
TC106 BARAGA FIBER BACKBONE CONNECTIVITY
TC107 BARAGA RACK LAYOUTS
TC108 BARAGA RACK LAYOUTS
TC109 BARAGA RACK LAYOUTS
TC110 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC111 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC112 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC113 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC114 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC115 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC116 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC117 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC118 BARAGA SECURITY CAMERA ONE LINE DIAGRAMS
TC201 BARAGA 100 ADMIN BUILDING FIRST FLOOR - EXISTING
TC202 BARAGA 100 ADMIN BUILDING SECOND FLOOR - EXISTING
TC203 BARAGA 300 EDUCATION FIRST FLOOR - EXISTING
TC204 BARAGA 300 EDUCATION SECOND FLOOR - EXISTING
TC205 BARAGA HOUSING UNIT 1 FIRST FLOOR - EXISTING
TC206 BARAGA HOUSING UNIT 1 SECOND FLOOR - EXISTING
TC207 BARAGA HOUSING UNIT 2 FIRST FLOOR - EXISTING
TC208 BARAGA HOUSING UNIT 2 SECOND FLOOR - EXISTING
TC209 BARAGA HOUSING UNIT 3 FIRST FLOOR - EXISTING
TC210 BARAGA HOUSING UNIT 3 SECOND FLOOR - EXISTING
TC211 BARAGA HOUSING UNIT 4 FIRST FLOOR - EXISTING
TC212 BARAGA HOUSING UNIT 4 SECOND FLOOR - EXISTING
TC213 BARAGA HOUSING UNIT 5 FIRST FLOOR - EXISTING
TC214 BARAGA HOUSING UNIT 5 SECOND FLOOR - EXISTING
TC215 BARAGA HOUSING UNIT 6 FIRST FLOOR - EXISTING
TC216 BARAGA HOUSING UNIT 6 SECOND FLOOR - EXISTING
TC217 BARAGA HOUSING UNIT 7 FIRST FLOOR - EXISTING
TC218 BARAGA HOUSING UNIT 7 SECOND FLOOR - EXISTING
TC219 BARAGA HOUSING UNIT 8 FIRST FLOOR - EXISTING
TC220 BARAGA 200 SUPPORT SERVICES FIRST FLOOR - EXISTING
TC221 BARAGA 200 SUPPORT SERVICES SECOND FLOOR - EXISTING
TC222 BARAGA 500 WAREHOUSE - EXISTING
TC223 BARAGA SITE PLAN - EXISTING
TC301 BARAGA 100 ADMIN BUILDING FIRST FLOOR - NEW & REPLACE
TC302 BARAGA 100 ADMIN BUILDING SECOND FLOOR - NEW & REPLACE
TC303 BARAGA 300 EDUCATION FIRST FLOOR - NEW & REPLACE
TC304 BARAGA 300 EDUCATION SECOND FLOOR - NEW & REPLACE
TC305 BARAGA HOUSING UNIT 1 FIRST FLOOR - NEW & REPLACE
TC306 BARAGA HOUSING UNIT 1 SECOND FLOOR - NEW & REPLACE
TC307 BARAGA HOUSING UNIT 2 FIRST FLOOR - NEW & REPLACE
TC308 BARAGA HOUSING UNIT 2 SECOND FLOOR - NEW & REPLACE
TC309 BARAGA HOUSING UNIT 3 FIRST FLOOR - NEW & REPLACE
TC310 BARAGA HOUSING UNIT 3 SECOND FLOOR - NEW & REPLACE
TC311 BARAGA HOUSING UNIT 4 FIRST FLOOR - NEW & REPLACE
TC312 BARAGA HOUSING UNIT 4 SECOND FLOOR - NEW & REPLACE
TC313 BARAGA HOUSING UNIT 5 FIRST FLOOR - NEW & REPLACE
TC314 BARAGA HOUSING UNIT 5 SECOND FLOOR - NEW & REPLACE
TC315 BARAGA HOUSING UNIT 6 FIRST FLOOR - NEW & REPLACE
TC316 BARAGA HOUSING UNIT 6 SECOND FLOOR - NEW & REPLACE
TC317 BARAGA HOUSING UNIT 7 FIRST FLOOR - NEW & REPLACE
TC318 BARAGA HOUSING UNIT 7 SECOND FLOOR - NEW & REPLACE
TC319 BARAGA HOUSING UNIT 8 FIRST FLOOR - NEW & REPLACE
TC320 BARAGA 200 SUPPORT SERVICES FIRST FLOOR - NEW & REPLACE
TC321 BARAGA 200 SUPPORT SERVICES SECOND FLOOR - NEW & REPLACE
TC322 BARAGA 500 WAREHOUSE - NEW & REPLACE
TC323 BARAGA SITE PLAN - NEW & REPLACE
STATE OF MICHIGAN
BARAGA CORRECTIONAL FACILITY
VIDEO MANAGEMENT SYSTEM UPGRADE -PHASE 1
BARAGA CORRECTIONAL FACILITY
FILE NUMBER: 472/21301.JBB
13924 Wadaga Rd, Baraga, MI 49908
ELECTRICAL ENGINEER
MATRIX CONSULTING ENGINEERS, INC.
1601 EAST GRAND RIVER
LANSING, MI 48906
(517) 487-2511
SECURITY DESIGN
COMMTECH DESIGN
6581 BELDING RD. NE, SUITE 101
ROCKFORD, MI 49341
(616) 863-8132
SECURITY DRAWING INDEXELECTRICAL DRAWING INDEX
BARAGA CORRECTIONAL FACILITY
13924 Wadaga Rd, Baraga, MI 49908
DRAWING LIST:
E-100 ELECTRICAL SYMBOLS, LEGENDS & LIGHT FIXTURE SCHEDULE
E-200 ELECTRICAL SITE PLAN
E-500 ADMIN BUILDING 100 1ST FLOOR POWER-NEW
E-501 ADMIN BUILDING 100 2ND FLOOR POWER-NEW
E-502 SUPPORT SERVICES BUILDING 200 1ST FLOOR POWER-NEW
E-503 SUPPORT SERVICES BUILDING 200 2ND FLOOR POWER-NEW
E-504 EDUCATION BUILDING 300 1ST FLOOR POWER-NEW
E-505 EDUCATION BUILDING 300 2ND FLOOR POWER-NEW
E-506 HOUSING UNIT 1 BUILDING 1ST FLOOR POWER-NEW
E-507 HOUSING UNIT 2 BUILDING 1ST FLOOR POWER-NEW
E-508 HOUSING UNIT 3 BUILDING 1ST FLOOR POWER-NEW
E-509 HOUSING UNIT 4 BUILDING 1ST FLOOR POWER-NEW
E-510 HOUSING UNIT 5 BUILDING 1ST FLOOR POWER-NEW
E-511 HOUSING UNIT 6 BUILDING 1ST FLOOR POWER-NEW
E-512 HOUSING UNIT 7 BUILDING 1ST FLOOR POWER-NEW
E-513 HOUSING UNIT 8 BUILDING MAIN POWER-NEW
E-514 MAINTENANCE BUILDING 500 FLOOR PLAN POWER-NEW
E-800 WALL FIELD BUILD-OUT FOR CAMERAS ON POLE FED FROM BUILDING DETAIL
E-801 TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM
COVER
C om m te ch
D es ig n
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
P . L
A C
H , R
A , D
IR
EC
TO
R
ST
A
TE
F
A C
IL
IT
IE
S
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
M a t r ix
AutoCAD SHX Text
SHEET NUMBER
AutoCAD SHX Text
472/21301.JBB
AutoCAD SHX Text file no.
AutoCAD SHX Text checked by
AutoCAD SHX Text drawn by
AutoCAD SHX Text consultant
AutoCAD SHX Text issue date
AutoCAD SHX Text acctg template.
AutoCAD SHX Text contract order no.
AutoCAD SHX Text 472AMFMaintproj
AutoCAD SHX Text consultant job no.
AutoCAD SHX Text 1065_24B
AutoCAD SHX Text sheet title
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text
VIDEO MANAGEMENT SYSTEM UPGRADE- PHASE 1
AutoCAD SHX Text
BARAGA CORRECTIONAL FACILITY
AutoCAD SHX Text
BARAGA, MICHIGAN
AutoCAD SHX Text
YXXXX
AutoCAD SHX Text
VIDEO SECURITY FLOOR PLANS
AutoCAD SHX Text 11/19/21
AutoCAD SHX Text
50%%% OWNER REVEIW
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text 1/24/22
AutoCAD SHX Text
90%%% OWNER REVIEW
AutoCAD SHX Text
CONSULTING ENGINEERS, INC
AutoCAD SHX Text
FAX: 517.487.2544
AutoCAD SHX Text
PHONE: 517.487.2511
AutoCAD SHX Text
LANSING, MI 48906
AutoCAD SHX Text
1601 E. GRAND RIVER AVE.
AutoCAD SHX Text
MATRIX PROJECT:
AutoCAD SHX Text WEB: www.matrixceinc.com
AutoCAD SHX Text 3/7/22
AutoCAD SHX Text
97%%% OWNER REVIEW
AutoCAD SHX Text 4/15/22
AutoCAD SHX Text
ISSUE FOR BID
X
X
X
TVSS
VFD
TRANSIENT VOLTAGE SURGE SUPPRESSION
VARIABLE FREQUENCY DRIVEDUPLEX RECEPTACLE
DOCK LIGHT FIXTURE
TELEPHONE / DATA OUTLET
ADDENDUM NOTE
PLAN NOTE
DEMOLITION NOTE
THREE PHASE MOTOR
ELECTRICAL SYMBOLS LEGEND
J
SINGLE RECEPTACLE (120 VOLT)
EMERGENCY RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
FLUSH FLOOR BOX
SURFACE FLOOR BOX
SPECIAL EQUIPMENT RECEPTACLE
TELEPHONE OUTLET
DATA OUTLET
POWER POLE
JUNCTION BOX
WALL JUNCTION BOX
PULL (JUNCTION) BOX
UNDERFLOOR JUNCTION BOX
OUTLETS
LIGHT FIXTURE
STRIP FIXTURE
IN-GRADE LIGHT FIXTURE
SPOTLIGHT (number of heads shown) EXIT SIGN (face & direction as shown)
WALL MOUNT LIGHT FIXTURE
CEILING LIGHT FIXTURE
TRACK & FIXTURE
STREET TYPE POLE FIXTURE
POLE MOUNTED LIGHT FIXTURE
EXTERIOR WALL MOUNT LIGHT FIXTURE
WALLPACK LIGHT FIXTURE
SPECIAL PURPOSE LIGHT FIXTURE
HIGH BAY LIGHT FIXTURE
EMERGENCY EGRESS LIGHT FIXTURE
(number of heads shown)
EMERGENCY LIGHT FIXTURE
FIXTURES
SWITCHES
SINGLE-POLE SWITCH
DIMMER SWITCH
TIME SWITCH
KEY SWITCH
MANUAL MOTOR SWITCH
THERMAL OVERLOAD SWITCH
SWITCH WITH PILOT LIGHT
FOUR-WAY SWITCH
THREE-WAY SWITCH
CIRCUITRY and RACEWAYS
UNDERFLOOR DUCT
BUS DUCT
PLUGMOLD AS SPECIFIED
WIREMOLD AS SPECIFIED
FLEXIBLE PIGTAILS/CONNECTIONS
"CONDUIT RUN CONTINUES" INDICATION
END OF CONDUIT RUN, CAP AND STAKE
END OF CONDUIT RUN
HOME RUN (with circuit numbers)
CONDUIT STUB DOWN
CONDUIT STUB UP
CONDUIT INSTALLED
CONDUIT INSTALLED
MECHANICAL
ELECTRIC WATER HEATER
ELECTRIC UNIT HEATER
PIPE TRACE HEATER
RESISTANCE HEATER, KW SHOWN
SINGLE PHASE MOTOR
SERVICE and EQUIPMENT
THERMOSTAT
CAPACITOR
ENCLOSED CIRCUIT BREAKER
TRANSFER SWITCH
WIREWAY
GROUND CONNECTION PER N.E.C.
TELEPHONE TERMINAL BOARD
GENERATOR, KW SHOWN
CURRENT TRANSFORMERS
UTILITY METER, AS REQUIRED
WEATHERHEAD
PANELBOARD, FLUSH MOUNTED
PANELBOARD, SURFACE MOUNTED
COMB. STARTER (BY x/C U.O.N.)
MAGNETIC STARTER (BY x/C U.O.N.)
DISCONNECT SWITCH (fuse size shown)
TRANSFORMER
CONTROL
xxVA connection by x/C) IRRIGATION CONTROLLER (120 volt
LIGHTING CONTACTOR
CONTROL TRANSFORMER
buttons indicated) PUSHBUTTON STATION (number of TIME CLOCK (24 hour U.O.N.)
PHOTOCELL (voltage as required)
HUMIDISTAT
DESIGNATIONS
(by E.C.)
(by others)
TT
G
WW
PC
CT
TS
T
H
TC
IC
T
1,3
OR
PM
WM
BD
UFD
F S
J
J
D
WH
PP
J
CEILING MOUNTED WIFI
POLE
PUMP
PANEL
P
PNL
PVC
PRV-
P-
PB
POLY VINYL CLORIDE
POWER ROOF VENTILATOR
PULL BOX
GENERAL CONTRACTOR
GROUND
HUMIDIFIERH-
GND
GFI
GC
GROUND FAULT INTERUPTER
ABBREVIATIONS LEGEND
POWER
SWITCH
RECEPT
SF-
SWBD
TCC
SPEC
SW
RGC
RTU-
PWR
VOLTS
WATTS
UF
V
W
UL
VL
UNO
UH-
TS
TYP
TR
ROOF TOP UNIT
RECEPTACLE
SWITCHBOARD
UNDER FLOOR
SPECIFICATIONS
RIGID GALVANIZED STEEL CONDUIT
UNLESS NOTED OTHERWISE
UNDERWRITERS' LABORATORIES, INC.
TAMPER PROOF RECEPTACLE
TAMPER PROOF SWITCH
TEMPERATURE CONTROL CONTRACTOR
VERIFY LOCATION WITH OWNER
TYPICAL
UNIT HEATER
SUPPLY FAN
WITH
WITHOUT
W/
XFMR
W/O
WP
TRANSFORMER
WEATHER PROOF
HOUR
LIGHT
JUNCTION BOX
LIGHT CONTROL
ISOLATED GROUND
HORSEPOWER
MINIMUM
MOUNT
MAKE-UP AIR UNIT
MOTOR CONTROL CENTER
MAIN LUG ONLY
MOUNTED
MOUNTING
MAXIMUM
LIGHTING
LT FLEX
MTD
MUAU-
MTG
MLO
MIN
MT
MC
MAX
MCC
LTG
IG
LC
LT
IMC
JB
HR
HVAC
HOA
HP
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NOT TO SCALE
NIGHT LIGHTNL
NTS
NO
NIC
NC
HAND-OFF-AUTO SELECTOR SWITCH
HEATING/VENTILATING/AIR CONDITIONING
INTERMEDIATE METAL CONDUIT
LIQUID TIGHT FLEXIBLE METAL CONDUIT
MECHANICAL CONTRACTOR
HID HIGH INTENSITY DISCHARGE
A
AC
AFF
ACU-
AHJ
AHU-
AS
B-
BC
AIC
ATS
BLDG
CHLR-
CND (C)
CKT BKR
CKT
CUH-
CU-
DISC
DFU-
EF-
EC
DWH-
EBB-
DWG
CT-
EXIST (E)
EWC
FLEX
FLA
FLR
FSES
FLUOR
EMT
ABOVE FINISHED FLOOR
AIR CONDITIONING UNIT
AMPS
ABOVE COUNTER
AIR HANDLING UNIT
AUTOMATIC TRANSFER SWITCH
AMPS INTERUPTING CAPACITY
AUTHORITY HAVING JURISDICTION
ABOVE SHELF
BOILER
BUILDING
BELOW COUNTER
CHILLER
DOMESTIC WATER HEATER
CABINET UNIT HEATER
CIRCUIT
CIRCUIT BREAKER
CONDUIT
CONDENSING UNIT
COOLING TOWER
DUCT FURNACE
DRAWING
DISCONNECT
FOOD SERVICE EQUIP. SUPPLIER
ELECTRIC WATER COOLER
ELECTRICAL CONTRACTOR
ELECTRIC BASEBOARD
ELECTRICAL METALLIC TUBING
EXISTING
EXHAUST FAN
FLOOR
FLUORESCENT
FLEXIBLE CONDUIT
FULL LOAD AMPS
EM EMERGENCY
F/S FIRE/SMOKE
FU- FURNACE
GENERAL ELECTRICAL NOTES
1. ALL WALL AND FLOOR PENETRATIONS ARE TO BE SEALED WITH LIKE
MATERIAL TO MAINTAIN ORIGINAL RATING.
2. ALL CONDUITS SHALL BE FIELD ROUTED ALONG EXISTING PIPING
AND STRUCTURAL STEEL.
3. CONTRACTORS SHALL VISIT THE PROJECT SITE DURING PRE-BID
WALK THROUGH TO DETERMINE THE EXACT EXTENT OF THE
DEMOLITION WORK REQUIRED BEFORE BIDDING THE PROJECT.
4. REMOVE ALL EXISTING OBSOLETE EXPOSED CONDUIT, WIRE AND
UNUSED EQUIPMENT WHERE WORK IS BEING DONE EXCEPT ITEMS
NOTED OTHERWISE.
5. WHERE BUILDING SURFACES ARE DAMAGED BY THE REMOVAL OF
OLD WORK, SURFACES SHALL BE PATCHED TO MATCH ADJACENT.
6. EXISTING WORK WHICH IS PRESENTLY CONCEALED AND WHICH WILL
REMAIN CONCEALED AND DOES NOT INTERFERE WITH ANY NEW
WORK OF ANY TRADE NEED NOT BE REMOVED. HOWEVER, ALL
CONDUIT SHALL BE CAPPED BELOW FINISH SURFACE AND THEN
PATCHED AND PAINTED TO MATCH, OR AS NOTED.
7. EXISTING OPENINGS, WHICH ARE TO BE REUSED, SHALL BE
MODIFIED OR ENLARGED TO SUIT THE NEW SYSTEMS AS REQUIRED.
PROVIDE ALL REQUIRED CUTTING AND PATCHING.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING THE EXISTING
WALLS TO MATCH THE ADJACENT SURFACES BEHIND ALL SURFACE
MOUNTED EQUIPMENT.
9. CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND LOADS
PRIOR TO INSTALLING SERVICE TO EQUIPMENT.
10. DRAWINGS ARE BASED ON EXISTING RECORD DOCUMENT AND
CASUAL FIELD OBSERVATION. REPORT ANY DISCREPANCIES TO
ENGINEER FOR CLARIFICATION.
11. MINIMUM RACEWAY SIZE; 34" TRADE SIZE. REFER TO SPECIFICATION
260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS.
12. ALL CONDUIT ABOVE 10 FOOT SHALL MEET THE FOLLOWING
REQUIREMENTS:
12.1. STRAP DISTANCE: 5 FEET.
12.2. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED-
GRC.
12.3. FITTINGS: COMPRESSION.
12.4. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES.
13. ALL CONDUIT BELOW 10 FOOT SHALL MEET THE FOLLOWING
REQUIREMENTS:
13.1. STRAP DISTANCE: 3 FEET.
13.2. FASTENERS: 2 HOLE WITH SECURITY SCREWS.
13.3. CONDUIT: INTERIOR EMT, EXTERIOR EXPOSED/ CONCEALED -
GRC.
13.4. FITTINGS: COMPRESSION.
13.5. BELL BOXES: FS TYPE.
13.6. NO KNOCKOUTS.
13.7. SECURE CONDUIT WITHIN 12 INCHES OF BOXES AND
ENCLOSURES
14. ALL EXPOSED WIRING SHALL BE IN CONDUIT. OPEN LOW VOLTAGE
WIRING ABOVE CEILINGS IS ACCEPTABLE.
15. CONDUITS SHALL BE INSTALLED STRAIGHT AND LEVEL AND SHALL BE
PARALLEL OR PERPENDICULAR TO THE BUILDING LINES.
16. CONTRACTOR SHALL VERIFY ALL VOLTAGES BEFORE CONNECTING
ANY EQUIPMENT.
17. ALL LOCATIONS WHERE THE WALLS CAN'T BE FISHED SHALL BE
SURFACE MOUNTED CONDUIT FOLLOWING NOTES 11 AND 12 ABOVE.
18. ALL WALLS THAT ARE ACCESSIBLE SHALL BE FISHED AND DEVICE
CUT INTO WALL.
19. ALL EXTERIOR CONCEALED CONDUIT UNDERGROUND SHALL BE RNC,
TYPE EPC-40-PVC
20. ANY ELECTRICAL OUTAGE SHALL NOT LAST OVER 2-HOURS. FOR
OUTAGES OVER PORTABLE GENERATORS SHALL BE USED TO
REPLACE ANY ELECTRICAL SERVICE EXCEEDING THAT DURATION.
21. UPON RELOCATING LIGHTS AND CAMERAS CONTRACTOR SHALL
VERIFY THAT THE LIGHTS AND CAMERAS ARE WORKING PROPERLY
PRIOR TO LEAVING THE SITE.
22. CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED
COMPONENTS, RACEWAYS, WIRE, AND HARDWARE, AS INDICATED ON
DRAWINGS.
23. ALL WORK DONE WITHOUT APPROVED SHOP DRAWINGS IS AT
CONTRACTORS RISK.
24. UPON RELOCATING LIGHTS AND CAMERAS CONTRACTOR SHALL
VERIFY THAT THE LIGHTS AND CAMERAS AREA WORKING PROPERLY
PRIOR TO LEAVING THE SITE.
20 KVA UPS - EQUIPMENT SPECIFICATION
20KW UNINTERRUPTABLE POWER SUPPLY (UPS)
PROVIDE UNINTERRUPTABLE POWER SUPPLY (UPS). UPS SHALL BE
LIEBERT EXM 20KW RATED, HIGH EFFICIENCY, DOUBLE CONVERSION,
CONTINUOUS DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 480VAC, 60HZ,
3-PHASE, 3-WIRE PLUS GROUND. OUTPUT VOLTAGE OF 208/120VAC, 60HZ,
3-PHASE, 4-WIRE PLUS GROUND. 65KAIC RATED. CONTINUOUS DUTY
STATIC BYPASS SWITCH, BACKLIT LCD CONTROL PANEL. INCLUDE FRONT
ACCESS, INDOOR RATED IP-20 ENCLOSURE. 13MIN. HITACHI-CSB
#HRL1234W-F2FR BATTERIES.
PROVIDE ONE 20KVA STEP-UP TRANSFORMER, 208:480/277VAC, 3-PHASE,
4-WIRE. PQI MODEL EY-60-020-208:480/277-150-K4-AL-ZS. TRANSFORMER
SHALL INCLUDE INDICATED 3-POLE OUTPUT BREAKERS.
INCLUDES SYSTEM START-UP SERVICES, USER TRAINING AND TWO-YEAR,
ON-SITE WARRANTY SERVICE FOR PARTS & LABOR.
SEQUENCE OF EQUIPMENT INSTALL:
1. INSTALL NEW 20KVA UPS ON RACK.
2. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.
3. REMOVE OLD UPS.
TYPICAL RACK MOUNTED 1500VA UPS- EQUIPMENT SPECIFICATION
1500VA UNINTERRUPTIBLE POWER SUPPLY (UPS)
PROVIDE RACK-MOUNTABLE, UNINTERRUPTIBLE POWER SUPPLY (UPS).
UPS SHALL BE 1.5KVA RATED, HIGH EFFICIENCY, DOUBLE CONVERSION,
CONTINUOUS DUTY, ON-LINE TYPE. INPUT VOLTAGE OF 120VAC, 60HZ,
1-PHASE, 3-WIRE PLUS GROUND. OUTPUT VOLTAGE OF 120VAC, 60HZ,
1-PHASE, 4-WIRE PLUS GROUND. 65KAIC RATED. INTEGRATED
MAINTENANCE BYPASS SWITCH, BACKLIT LCD CONTROL PANEL. INCLUDE
WEB CARD AND ALARM RELAY BOARD FOR REMOTE MONITORING,
INDOOR RATED IP-20 ENCLOSURE. ENERGY SEALED CELL BATTERIES.
5-MINUTE RUN TIME. SELF DIAGNOSTICS. HARD-WIRED TERMINALS FOR
CONNECTION TO EXTERNAL 120VAC, 1PH POWER PANEL.
LIEBERT GXT5-15000
INSTALLER PROVIDED INPUT AND OUTPUT CABLING SHALL BE FLEXIBLE
CONDUIT TO ALLOW UPS POD BYPASS MODULE WITHOUT POWERING
DOWN THE LOAD.
INCLUDE SYSTEM START-UP SERVICES, USER TRAINING AND TWO-YEAR,
ON-SITE WARRANTY SERVICE FOR PARTS & LABOR.
SEQUENCE OF EQUIPMENT INSTALL:
1. INSTALL NEW 1500VA UPS ON RACK.
2. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.
3. REMOVE OLD UPS.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-100
ELECTRICAL SITE
PLAN - NEW
JKB
JFS
C
XX
X X
X X
X X
XX
X X
X X
X X X
X
X
XXXXXX
X
X
X
X X
XX
X X
X X
X
X
X
X
X
XX
X X
X X
X X
X
X X
X
X
X
X
X
XX
X X
X
X
X
X
X
X
X X
X X
X
X
X X X X X
X
X
X
X
XX
X X
X X
X X X X X X X X
X X
X X
XXXX
X
X X X
X X
X X
X
X X
X
XXXXXXXXX
X X
X
X
X X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X X X X
X X
X X
X X
X
X
X X
X X
X
X
X
X
X X
X X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
XX
X X
X X
X X
X
X
X X X X X X X X X X X X X X X X X X X X X
XX
X X
X X
X X
X X
X X
X X
X X
X
X
X X
X
X
X
X X X X X X X X X X X X X X X X X X
X X
X
X
X
X
X
X
X
X
X
X
XX
XXXXXXXXXX
X X X X X X X X X X
X
X
X
X X
X X
XXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X X
DRAWING SHEETS
E502 E503
DRAWING SHEETS
E506
DRAWING SHEETS
E507
DRAWING SHEETS
E510
DRAWING SHEETS
E504 E505
DRAWING SHEETS
E500 E501
DRAWING SHEETS
E508
DRAWING SHEETS
E509
DRAWING SHEETS
E511
DRAWING SHEETS
E512
DRAWING SHEETS
E513
DRAWING SHEETS
E514
PL-214PL-139
PL-142
PL-138
PL-207PL-206
PL-208
PL-209
PL-210
PL-211PL-212PL-213
PL-215
PL-216
PL-217
PL-204 PL-205
PL-137
PL-136
PL-135
PL-134
PL-133
PL-132
PL-131PL-127PL-126PL-124PL-123PL-122
PL-121
PL-120PL-116
PL-115
PL-114
PL-113
PL-112
PL-111
PL-110
PL-109
PL-108
PL-107
PL-103
PL-102 PL-101 PL-100
PL-158
PL-157
PL-148
PL-147
PL-146 PL-145 PL-144
PL-143
PL-141
PL-140
PL-125
PL-128
PL-129
PL-130
PL-117
PL-118
PL-119
PL-104
PL-105
PL-106
ELECTRICAL KEY NOTES
INSTALL SURGE PROTECTION DEVICES / JUNCTION BOXES
TO CAMERA ON POLE.
DIRECTIONAL BORE BETWEEN CAB-1 AND BUILDING 500 TO
ADD FIBER FOR CABINETS AND CONTROL WIRING FOR (4)
SALLY PORT MICROWAVES. ADD INTERDUCT WITH 25 PAIR
COPPER AND FIBER OPTIC CABLE. SEE DETAIL E-200/A.
INSTALL SURGE PROTECTION DEVICES IN ATTIC TO CAMERA
ON BUILDING.
1 1
1 1
3 3
GUARD
TOWER 1
HAND
HOLE
CAB-1
TO
MAINTENANCE
BUILDING 500
25 PAIR COPPER
(1) 1-1/4" CONDUIT
FIBER CABLE
(1) 1-1/4" CONDUIT
FIBER CABLE AND 25 PAIR COPPER
(1) 3" CONDUIT WITH INTERDUCT
A E-200
DIRECTIONAL BORE DETAIL
SCALE: N.T.S.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-200
ELECTRICAL SITE
POWER PLAN - NEW
JKB
JFS
N
SCALE: 1" = 100'
25080400 20 160
ELECTRICAL - BARAGA SITE PLAN
ELECTRICAL KEY NOTES
PROVIDE A DEDICATED RECEPTACLE FROM NEW SUB PANEL
ON SECOND FLOOR.
1 1 1
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-500
ELECTRICAL BUILDING 100
1ST FLOOR POWER PLAN -
NEW
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA ADMIN BUILDING 100
1ST FLOOR POWER-NEW
EXISTING PANEL LP-XX
277/480V-3PH-4W
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW 20KVA UPS FOR CAMERAS. SEE
DETAIL E-501/A.
RE-FEED EXISTING RECEPTACLES FROM NEW SUB PANEL.
PROVIDE AND INSTALL NEW 120V RECEPTACLE FROM NEW
SUB PANEL.
EX FIBER PANEL AND
VIDEO SECURITY SWITCH
ON RACK
NEW FIBER PANEL
AND VIDEO RACK
NEW SUB PANEL
NEW 20KVA
UPS
NEW 20KVA
XFMR
1 3
PANEL
NEW SUB
RP-XA
120/208V 3Ø, 4W
70A / MCB
NEW 30 KVA XFMR
PRIMARY: 480V
SECONDARY: 208V
208 VOLTS
208 VOLTS
208 VOLTS
480 VOLTS
480 VOLTS
480 VOLTS
NEW 20KVA UPS
(3) #8 AWG
(1) #10 AWG GND
(1) 3/4" CND
EXTEND
EXISTING
WIRES
(3) #3 AWG
(1) #6 AWG GND
(1) 1" CND
(3) #4 AWG
(1) #8 AWG GND
(1) 1" CND
(3) #4 AWG
(1) #8 AWG GND
(1) 1" CND
90A
25A / 3P
25A / 3P
FROM LP-XX
45A / 3P
TO SITE CABINETS
TO SITE CABINETS
A E-501
20 KVA UPS DETAIL
SCALE: N.T.S.
70A
NEW 20 KVA XFMR
PRIMARY: 208V
SECONDARY: 480V
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-501
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA ADMIN BUILDING 100
2ND FLOOR POWER-NEW
ELECTRICAL BUILDING 100
2ND FLOOR POWER PLAN -
NEW
PROVIDE AND INSTALL NEW RACK AND NEW 1500VA RACK
MOUNTED UPS TO BACK UP CAMERAS. COORDINATE WITH
COMMTECH ON RACK DESIGN AND LOCATION.
PROVIDE A DEDICATED GENERATOR POWERED CIRCUIT
FROM NEAREST 120V PANEL, PROVIDE AND INSTALL 20A-1P
BREAKER AS REQUIRED.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-502
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA SUPPORT SERVICES BUILDING 200
1ST FLOOR POWER-NEW
ELECTRICAL BUILDING 200
1ST FLOOR POWER PLAN -
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK1
ELECTRICAL KEY NOTES
REPLACE EXISTING CAMERA UPS WITH NEW RACK 1500VA
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK LOCATION.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-503
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA SUPPORT SERVICES BUILDING 200
2ND FLOOR POWER-NEW
ELECTRICAL BUILDING 200
PROVIDE AND INSTALL NEW 1500VA UPS TO BACK UP
CAMERAS. COORDINATE WITH COMMTECH ON UPS
LOCATION.
PROVIDE A DEDICATED GENERATOR POWERED CIRCUIT
FROM NEAREST 120V PANEL, PROVIDE AND INSTALL 20A-1P
BREAKER AS REQUIRED.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-504
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA EDUCATION BUILDING 300
1ST FLOOR POWER-NEW
ELECTRICAL BUILDING 300
1ST FLOOR POWER PLAN -
REPLACE EXISTING EQUIPMENT WITH NEW RACK MOUNTED
1500VA UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND
VIDEO SECURITY
SWITCH ON RACK
TEX
EXISTING
PANEL
LP-X
EXISTING
PANEL
LP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-505
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA EDUCATION BUILDING 300
2ND FLOOR POWER-NEW
ELECTRICAL BUILDING 300
REPLACE EXISTING CAMERA UPS WITH NEW RACK 1500VA
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-506
ELECTRICAL HOUSING
UNIT 1 POWER PLAN - NEW
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 1 BUILDING
1ST FLOOR POWER-NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-507
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 2 BUILDING
1ST FLOOR POWER-NEW
ELECTRICAL HOUSING
UNIT 2 POWER PLAN - NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-508
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL-BARAGA HOUSING UNIT 3 BUILDING
1ST FLOOR POWER-NEW
UNIT 3 POWER PLAN - NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-509
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 4 BUILDING
1ST FLOOR POWER-NEW
UNIT 4 POWER PLAN - NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-510
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 5 BUILDING
1ST FLOOR POWER-NEW
UNIT 5 POWER PLAN - NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-511
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 6 BUILDING
1ST FLOOR POWER-NEW
UNIT 6 POWER PLAN - NEW
MOUNTED UPS TO BACK UP EQUIPMENT IN EXISTING RACK.
COORDINATE WITH COMMTECH ON RACK DESIGN.
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK 1
EXISTING
PANEL RP-X
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-512
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 7 BUILDING
1ST FLOOR POWER-NEW
UNIT 7 POWER PLAN - NEW
2 2
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW RACK MOUNTED UPS TO BACK
UP EQUIPMENT IN EXISTING RACK. COORDINATE WITH
COMMTECH ON RACK DESIGN.
PROVIDE A DEDICATED GENERATOR POWERED CIRCUIT
FROM NEAREST 120V PANEL, PROVIDE AND INSTALL 20A-1P
BREAKER AS REQUIRED.
SEQUENCE OF EQUIPMENT INSTALL TO BE COMPLETED AFTER NEW RACH
HAS BEEN INTALLED:
1. INSTALL NEW 1500VA UPS ON NEW DATA RACK.
2. RELOCATE CAMERA EQUIPMENT POWER TO NEW UPS.
3. REMOVE OLD UPS.
GENERAL ELECTRICAL NOTES
EX FIBER PANEL AND VIDEO
SECURITY SWITCH ON RACK
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-513
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA HOUSING UNIT 8 BUILDING
MAIN POWER-NEW
UNIT 8 POWER PLAN - NEW
EX FIBER PANEL AND
VIDEO SECURITY
SWITCH ON RACK
ELECTRICAL KEY NOTES
PROVIDE AND INSTALL NEW RACK MOUNTED UPS TO BACK
UP EQUIPMENT IN EXISTING RACK. COORDINATE WITH
COMMTECH ON RACK DESIGN.
PROVIDE A DEDICATED GENERATOR POWERED CIRCUIT
FROM NEAREST 120V PANEL, PROVIDE AND INSTALL 20A-1P
BREAKER AS REQUIRED.
RELOCATE MICROWAVE CONTROLLER TO THIS GENERAL
LOCATION. FEED (4) MICROWAVES IN SALLY PORT.
DIRECTIONAL BORE TO HAND HOLE BETWEEN CAB-1
AND GUARD TOWER 1. ADD INTERDUCT, 25 PAIR
COPPER, AND FIBER.
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-514
ELECTRICAL BUILDING
500 POWER PLAN - NEW
JKB
JFS
N
SCALE: 1/8" = 1'-0"
0 1 5 10 20
ELECTRICAL- BARAGA MAINTENANCE BUILDING 500
FLOOR PLAN POWER-NEW
CAMERA JUNCTION BOX INSTALLATION DETAIL
SCALE: N.T.S.
#10 AWG
#10 AWG
#10 AWG
#10 AWG
ETHERNET SWITCH
CABINET
LIGHTING ARRESTORS
ELECTRICAL EQUIPMENT
TYPICAL FOR EACH
PIECE OF
EQUIPMENT
CONNECT TO GROUND BAR
#10 AWG
TELECOMMUNICATIONS GROUND BAR
GROUND BAR TYPICAL
TYPICAL CRIMP LUG CONNECTIVITY
1. ALL GROUNDING CONNECTIONS SHALL BE ROUTED TO CLOSEST
GROUND BAR.
2. GROUND BAR WILL BE PROVIDED WITH THE CABINET AND WILL BE
CONNECTED TO THE EARTH & ELECTRICAL GROUNDING SYSTEM.
3. ALL BONDING CONNECTIONS SHALL BE MAKE WITH TWO HOLE
CRIMP LUGS ONLY AT THE GROUND BAR.
4. FROND CONNECTIONS SHALL BE MAKE WITH A MINIMUM OF #10
AWG CABLE.
5. ALL GROUND WIRES SHALL HAVE GREEN INSULATION.
GROUNDING NOTES
COMMUNICATIONS GROUNDING DETAIL
SCALE: N.T.S.
K K
POWER STRIP FED FROM
UPS.
SURGE SUPPRESSORS,
LIGHTING ARRESTORS.
POE INJECTORS.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX. TERMINATE
ALL NEW CABLES HERE FOR TESTING.
TYPICAL COMMUNICATION CONDUITS TO
LIGHT POLES AND OTHER CABINETS.
GROUND BAR.
EXISTING CAT 6 CABLES TO CAMERAS.
EXISTING CAT 6 CABLES TO CAMERAS.
EXISTING CAT 6 CABLES TO CAMERAS.
2'X2' FIREPROOF PLYWOOD
WALLFIELD.
NEW CAT 6 CABLES TO CAMERAS.
NEW CAT 6 CABLES TO CAMERAS.
EXISTING CAT 6 CABLES TO CAMERAS.
NEW CAT 6 CABLES TO CAMERAS.
NEW CAT 6 CABLES TO CAMERAS.
CAT-6 PATCH CABLES
ADD D-RINGS WHERE NECCESARY.
WALL FIELD BUILD-OUT FOR CAMERAS ON POLES FED FROM BUILDINGS DETAIL
SCALE: N.T.S.
CAT-6 CABLE TO
COMMUNICATIONS
ROOM.
15" DATA SERVICE LOOP. SUPPORT TO
STRUCTURE.
EXTERIOR CAMERA MOUNTED
TO BUILDING WALL.
NEW CAT-6 PATCH CABLE.
SURGE PROTECTION DEVICE.
EXTERIOR CAMERA CABLING DETAIL
SCALE: N.T.S.
2 K
MOUNTING POLE
TYPICAL
COMMUNICATIONS
CONDUITS TO LIGHT
POLES AND OTHER
CABINETS.
MODULAR JACKS IN SURFACE MOUNT BOX.
TERMINATE ALL NEW CABLES HERE FOR
TESTING.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX. TERMINATE
ALL NEW CABLES HERE FOR TESTING.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX.
EXISTING MODULAR JACKS IN
SURFACE MOUNT BOX.
MOUNTING POLE
SURGE PROTECTION DEVICES,
LIGHTING ARRESTORS.
POE INJECTORS
POWER SUPPLY FOR
ETHERNET SWITCH-
TO REMAIN
ETHERNET SWITCH FUTURE SWITCH
POWER SUPPLY FOR
ETHERNET SWITCH-
FUTURE
EXISTING FIBER OPTIC PATCH
PANEL
RESERVED FOR ELECTRICAL
PLUG STRIP- EXISTING
GROUND BAR- EXISTING
NETWORK CABINET DETAIL - TYPICAL FOR PERIMETER CABINETS
SCALE: N.T.S.
GRADE
EXISTING
CONDUITS.
CAMERA MOUNTED ON POLE DETAIL
SCALE: N.T.S.
EXISTING REBAR
CAGES.
EXISTING ANCHOR BOLTS
BOLT PATTERN FIELD
VERIFY PATTERN
EXISTING
GROUT UNDER POLE BASE
EXISTING
GROUND ROD
EXISTING
CADWELD
HANDHOLE
EXISTING FIXED CAMERA
MOUNTING HEIGHT
EXISTING
1" TYPE C
JUNCTION BOX
16' AFG MINIMUM
OR 2' ABOVE
RAZORWIRE
MINIMUM
EXISTING JUNCTION
BOX
EXISTING
1" PVC (CAMERA CABLE) FROM
CABINET
EXISTING
FLEXIBLE, WATER-PROOF
RUBBER COUPLING.
EXISTING
1" RGS LOW VOLTAGE
CONDUIT
EXISTING
CONCRETE BASE OR
PRECAST BASE.
EXISTING POLE
22' AFG MINIMUM
EXISTING PTZ CAMERA
MOUNTING HEIGHT
TO UPS.
TO POWER SOURCE
ELECTRICAL KEY NOTES
RE-TERMINATE EXISTING CAT 6 CABLE FROM CAMERA HEAD AT SURGE
PROTECTION DEVICE. PROVIDE AND INSTALL NEW CAT 6 CABLE FROM SURGE
PROTECTION DEVICE TO CAMERA HEAD.
NEW 1" CONDUIT TO CAMERA
EXISTING 1" CONDUIT TO
CABINET
NEW SURGE
SUPPRESSOR
RAY CAP CAT6-POE-I
EXISTING 8"W X 8"H X 4"D
ENCLOSURE, NEMA 4, HINGED
JUNCTION BOX. HOFFMAN
A808CHNF WITH A8P8G PANEL
OR EQUAL.
PROVIDE WITH PAD
LOCKABLE HASP
STAINLESS
STEEL PIPE
STRAP, TYP.
STEEL
CHANNEL,
UNISTRUT OR
EQ.
EXISTING #6 COPPER
GROUND WIRE IN 3/4" PVC
CONDUIT TO 3/4" X 8' GROUND
ROD.
POLE
EXISTING CONNECT
GROUND WIRE TO
GROUND BAR.
JUMPER TO TSS WITH #12G.
SIDE VIEWFRONT VIEW
TSS EXISTING 1"x3"x1/4" TK.
COPPER GROUND BAR.
NEW 1" CONDUIT
NEW BACK BOX C
om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-800
ELECTRICAL DETAILS
TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM
SCALE: N.T.S.
CAB-XXX
ETHERNET
SWITCH
POE
INJECTOR
SURGE
PROTECTOR
SURGE
PROTECTOR
PERIMETER CABINET
CONNECT TO GROUND BAR
#10 AWG TYP.
EXISTING CAT-6 CABLE IN CONDUIT
NEW CAT-6 PATCH
CABLE IN CONDUIT
EXISTING JUNCTION BOX
EXISTING
FIXED CAMERA
L
NA
J
J
ETHERNET SWITCH
POE POWER
INJECTOR
SURGE PROTECTION
DEVICE
SURGE PROTECTION
DEVICE
MODULAR JACKS IN SURFACE MOUNT BOX.
TERMINATE ALL NOW CABLES HERE FOR
TESTING.
SHIELDED CAT-6 PATCH
CABLE FROM POLE TO
CABINET.
CAT-6 PATCH
CABLE
NEW CAT-6 PATCH
CABLE
GROUND CABLE
GROUND CABLE
GROUND ROD
FIXED OR PTZ CAMERA
ON POLE
CAMERA CONNECTIVITY AT CABINET CAMERA CONNECTIVITY AT POLE
TYPICAL PERIMETER CAMERA CONNECTIVITY DIAGRAM
SCALE: N.T.S.
NEW 1" CONDUIT
NEW CAT-6 PATCH
CABLE IN CONDUIT
EXISTING JUNCTION BOX
NEW 1" CONDUIT
EXISTING
FIXED CAMERA
C om m te ch
D es ig n
472/21301.JBB
file no.
checked by drawn by consultant issue date acctg template.
contract order no.
472AMFMaintproj consultant job no.
1065_24B sheet title
YXXXX
C O
U R
TL
AN
D S
T.
, S
U
IT
E
R
O C
KF
O
R D
, M
IC
H
IG
AN
W W
W .C
O M
M
TE
C H
D
ES
IG
N
.C O
M
VIDEO SECURITY FLOOR
PLANS
11/19/21 50% OWNER REVEIW
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L
A C
H R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
1/24/22 90% OWNER REVIEW
M a t r ix
3/07/22 97% OWNER REVIEW
04/01/22 BID SET
E-801
ELECTRICAL
DIAGRAMS
| E100-2131601-30x42 |
| E200-2131601-30x42 |
| E500-2131601-30x42 |
| E501-2131601-30x42 |
| E502-2131601-30x42 |
| E503-2131601-30x42 |
| E504-2131601-30x42 |
| E505-2131601-30x42 |
| E506-2131601-30x42 |
| E507-2131601-30x42 |
| E508-2131601-30x42 |
| E509-2131601-30x42 |
| E510-2131601-30x42 |
| E511-2131601-30x42 |
| E512-2131601-30x42 |
| E513-2131601-30x42 |
| E514-2131601-30x42 |
| E800-2131601-30x42 |
| E801-2131601-30x42 |
File details come from the government source that posted it. Updated .