This document appears to be a product description and packaging specification for Mesh Drawers, which are part of the United States Marine Corps Cold Weather Clothing Base Layer Set Layering System. The drawers must be manufactured in accordance with MIL-DTL-32740 with Amendment 1, dated 25 March 2024. The pattern date is 17 August 2023, and the shade standard is available under Interim Roll Number 3893. The document provides detailed packaging, inspection, and marking requirements, including case lot quantities, testing of materials, and visual and dimensional acceptance criteria. A related federal contract opportunity is also described, which seeks market research for the Mesh Drawers (PGC 00472) as well as a Cold Weather Undershirt (PGC 00471). The opportunity is being issued by the Defense Logistics Agency.

View the file

Other files

File Type Posted
MIL-DTL-32740w Amd 1 25 Mar 2024.pdf PDF
MIL-DTL-32741w AMD 1 25 Mar 2024.pdf PDF
PGC 00471 TechData.doc DOC document
Market Survey Cold Weather Undershirt 00472.xlsx XLSX spreadsheet
Market Survey Cold Weather Drawers 00471.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(Drawers, Mesh, CW)

NSN(S) THIS PROCUREMENT

NSN

Size

UPC

8415-01-696-9369

X-SMALL

718020748054

8415-01-696-9376

SMALL

718020632544 8415-01-696-9408

MEDIUM

718020935393

8415-01-696-9409

LARGE

718020907895

8415-01-696-9443

X-LARGE

718020805481

8415-01-696-9446

XX-LARGE

718020809281

8415-01-696-9448

XXX-LARGE

718020810911

SECTION C- DESCRIPTION/SPECIFICATION

ITEM DESCRIPTION

DRAWERS, MESH, COLD WEATHER, BASELAYER

PART OF THE UNITED STATES MARINE CORPS COLD WEATHER CLOTHING BASE LAYER SET LAYERING SYSTEM.

DRAWERS SHALL BE MADE IN ACCORDANCE WITH MIL-DTL-32740 w/AMENDMENT 1, DATED 25 MARCH 2024.

PATTERN DATE: 17 AUGUST 2023

SHADE STANDARD IS AVAILABLE UNDER INTERIM ROLL NUMBER 3893. FOR SHADE ONLY.

Packaging examination. The fully packaged end item shall be examined for the defects listed below. The lot size shall be expressed in units of shipping containers. The sample unit shall be one shipping container fully packaged. The Inspection level shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.

Examine Defect

Marking Omitted; incorrect; illegible, of (exterior) improper size, location, sequence & Unit Pack, or method of application.

Materials Any component missing, damaged or not as specified.

Workmanship Inadequate application of components, such as: incomplete closure of container flaps, loose strapping, improper taping, or inadequate stapling. Bulged or distorted container.

Contents Number of intermediate containers per shipping container is more or less than required.

Number of items per container is more or less than required.

Palletization examination. The fully packaged and palletized end items shall be examined for the defects listed below. The lot size shall be expressed in units of palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.

The Inspection level shall be S-1 and the AQL, expressed in terms of defects per hundred units, shall be 6.5.

Examine Defect

Finished Length, width or height exceeds Dimensions specified maximum requirement.

Palletization Pallet pattern not as specified.

Interlocking of loads not as specified. Load not bonded with required straps as specified.

Weight Exceeds maximum load limits.

Marking Omitted; incorrect; illegible; of improper size, location, sequence or method of application.

DEVIATION/CHANGES TO MIL-STD-129R, WITH CHANGE 3, DATED 25 FEBRUARY 2023

DEVIATION/CHANGES TO MIL-STD-147E WITH CHANGE 2, DATED 27 JUNE 2019

DEVIATION/CHANGES TO ANSI/ASQC Z1.4: NOTE: THE MOST RECENT VERSION OF THIS DOCUMENT SHOULD BE USED. APPLICATION FOR COPIES SHOULD BE ADDRESSED TO:

AMERICAN SOCIETY FOR QUALITY

600 NORTH PLANKINTON AVENUE

MILWAUKEE, WISCONSIN 53203

SECTION D – PACKAGING AND MARKING

CASE LOT QUANTITY OF 30 DRAWERS SAME SIZE.

EACH DRAWERS SHALL BE PACKED IN A CLEAR, POLY BAG WITH REVERSE FLAP CLOSURE, WITH TAGS/LABELS CLEARLY VISIBLE.

TESTING OF THE PHYSICAL CHARACTERISTICS OF THE BASIC MATERIAL CLOTH IS REQUIRED.

CERTIFICATE OF COMPLIANCE IS ACCEPTABLE FOR OTHER COMPONENTS.

GENERAL INSPECTION LEVEL II IN ACCORDANCE WITH LASTEST VERSION OF ANSI/ASQ Z1.4 FOR VISUAL AND DIMENSIONAL.

END ITEM VISUAL: THE LOT SIZE SHALL BE EXPRESSED IN UNITS OF DRAWERS. THE SAMPLE UNIT SHALL BE ONE DRAWERS. THE INSPECTION LEVEL SHALL BE II AND THE ACCEPTABLE QUALITY LEVEL (AQL), EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 2.5.

END ITEM DIMENSIONAL: ANY DIMENSION NOT WITHIN THE SPECIFIED TOLERANCE SHALL BE CLASSIFIED AS A DEFECT. THE LOT SIZE SHALL BE EXPRESSED IN UNITS OF DRAWERS. THE SAMPLE UNIT SHALL BE ONE DRAWERS. THE INSPECTION LEVEL SHALL BE S-3 AND THE AQL, EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 4.0.

AS A MINIMUM ITEM SHALL BE PACKED IN A SNUG FITTING FIBERBOARD SHIPPING CONTAINER CONFORMING TO ASTM-D-5118, TYPE CF, STYLE RSC, GRADE 275 OR ECT44, VARIETY SW, CLASS DOMESTIC, WITH A DOUBLE WALL LINER. ANY COMMERCIAL CLOSURE METHOD CITED IN ASTM-D-1974 IS ACCEPTABLE EXCEPT STAPLING.

PACKAGING SHALL BE AS PER ASTM-D-3951, MIL-STD-129R, and MIL-STD-147E.

LOT NUMBERING SHALL BE IN ACCORDANCE WITH MIL-STD-129R AND DLA Troop Support Clothing & Textiles Additional Quality Assurance Requirements dated August 2021.