PGC 00471 TechData.doc
DOC document 43 KB Posted
- Solicitation number
- Not on record
- Issued by
-
Defense Logistics Agency
About this file
This document appears to be a technical data sheet for a Cold Weather Undershirt (PGC 00471) that is part of the United States Marine Corps Cold Weather Clothing Base Layer Set. The undershirt shall be made in accordance with MIL-DTL-32741 with Amendment 1, dated 25 March 2024, and has a pattern date of 17 August 2023.
The technical data sheet provides detailed specifications for the undershirt, including NSN numbers, sizes, UPC codes, packaging requirements, and inspection/testing standards. It specifies that the undershirt shall be packed in clear poly bags and shipped in snug-fitting fiberboard containers. Packaging must comply with ASTM, MIL-STD-129R, and MIL-STD-147E standards. Visual and dimensional inspections are required, with specified lot sizes, sample units, inspection levels, and acceptable quality levels.
The related federal contract opportunity is a Request for Market Research for both the Cold Weather Undershirt (PGC 00471) and Cold Weather Drawers (PGC 00472), which shall be made in accordance with MIL-DTL-32741 and MIL-DTL-32740, respectively, with Amendment 1 dated 25 March 2024. The opportunity is being issued by the Defense Logistics Agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MIL-DTL-32740w Amd 1 25 Mar 2024.pdf | ||
| MIL-DTL-32741w AMD 1 25 Mar 2024.pdf | ||
| Market Survey Cold Weather Undershirt 00472.xlsx | XLSX spreadsheet | |
| PGC 00472 TechData.doc | DOC document | |
| Market Survey Cold Weather Drawers 00471.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(Undershirt, Mesh, CW)
NSN(S) THIS PROCUREMENT
NSN
Size
UPC
8415-01-696-8286
X-SMALL
718020783635
8415-01-696-8303
SMALL
718020862415 8415-01-696-8304
MEDIUM
718020757889
8415-01-696-8305
LARGE
718020958989
8415-01-696-8306
X-LARGE
718020658278
8415-01-696-8307
XX-LARGE
718020731452
8415-01-696-8308
XXX-LARGE
718020997209
SECTION C- DESCRIPTION/SPECIFICATION
ITEM DESCRIPTION
UNDERSHIRT, MESH, COLD WEATHER, BASELAYER
PART OF THE UNITED STATES MARINE CORPS COLD WEATHER CLOTHING BASE LAYER SET LAYERING SYSTEM.
UNDERSHIRT SHALL BE MADE IN ACCORDANCE WITH MIL-DTL-32741 w/AMENDMENT 1, DATED 25 MARCH 2024.
PATTERN DATE: 17 AUGUST 2023
SHADE STANDARD IS AVAILABLE UNDER INTERIM ROLL NUMBER 3893. FOR SHADE ONLY.
Packaging examination. The fully packaged end item shall be examined for the defects listed below. The lot size shall be expressed in units of shipping containers. The sample unit shall be one shipping container fully packaged. The Inspection level shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.
Examine Defect
Marking Omitted; incorrect; illegible, of (exterior) improper size, location, sequence & Unit Pack, or method of application.
Materials Any component missing, damaged or not as specified.
Workmanship Inadequate application of components, such as: incomplete closure of container flaps, loose strapping, improper taping, or inadequate stapling. Bulged or distorted container.
Contents Number of intermediate containers per shipping container is more or less than required.
Number of items per container is more or less than required.
Palletization examination. The fully packaged and palletized end items shall be examined for the defects listed below. The lot size shall be expressed in units of palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.
The Inspection level shall be S-1 and the AQL, expressed in terms of defects per hundred units, shall be 6.5.
Examine Defect
Finished Length, width or height exceeds Dimensions specified maximum requirement.
Palletization Pallet pattern not as specified.
Interlocking of loads not as specified. Load not bonded with required straps as specified.
Weight Exceeds maximum load limits.
Marking Omitted; incorrect; illegible; of improper size, location, sequence or method of application.
DEVIATION/CHANGES TO MIL-STD-129R, WITH CHANGE 3, DATED 25 FEBRUARY 2023
DEVIATION/CHANGES TO MIL-STD-147E WITH CHANGE 2, DATED 27 JUNE 2019
DEVIATION/CHANGES TO ANSI/ASQC Z1.4: NOTE: THE MOST RECENT VERSION OF THIS DOCUMENT SHOULD BE USED. APPLICATION FOR COPIES SHOULD BE ADDRESSED TO:
AMERICAN SOCIETY FOR QUALITY
600 NORTH PLANKINTON AVENUE
MILWAUKEE, WISCONSIN 53203
SECTION D – PACKAGING AND MARKING
CASE LOT QUANTITY OF 20 UNDERSHIRTS SAME SIZE.
EACH UNDERSHIRT SHALL BE PACKED IN A CLEAR, POLY BAG WITH REVERSE FLAP CLOSURE, WITH TAGS/LABELS CLEARLY VISIBLE.
TESTING OF THE PHYSICAL CHARACTERISTICS OF THE BASIC MATERIAL CLOTH IS REQUIRED.
CERTIFICATE OF COMPLIANCE IS ACCEPTABLE FOR OTHER COMPONENTS.
GENERAL INSPECTION LEVEL II IN ACCORDANCE WITH LASTEST VERSION OF ANSI/ASQ Z1.4 FOR VISUAL AND DIMENSIONAL.
END ITEM VISUAL: THE LOT SIZE SHALL BE EXPRESSED IN UNITS OF UNDERSHIRTS. THE SAMPLE UNIT SHALL BE ONE UNDERSHIRT. THE INSPECTION LEVEL SHALL BE II AND THE ACCEPTABLE QUALITY LEVEL (AQL), EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 2.5.
END ITEM DIMENSIONAL: ANY DIMENSION NOT WITHIN THE SPECIFIED TOLERANCE SHALL BE CLASSIFIED AS A DEFECT. THE LOT SIZE SHALL BE EXPRESSED IN UNITS OF UNDERSHIRTS. THE SAMPLE UNIT SHALL BE ONE UNDERSHIRT. THE INSPECTION LEVEL SHALL BE S-3 AND THE AQL, EXPRESSED IN TERMS OF DEFECTS PER HUNDRED UNITS, SHALL BE 4.0.
AS A MINIMUM ITEM SHALL BE PACKED IN A SNUG FITTING FIBERBOARD SHIPPING CONTAINER CONFORMING TO ASTM-D-5118, TYPE CF, STYLE RSC, GRADE 275 OR ECT44, VARIETY SW, CLASS DOMESTIC, WITH A DOUBLE WALL LINER. ANY COMMERCIAL CLOSURE METHOD CITED IN ASTM-D-1974 IS ACCEPTABLE EXCEPT STAPLING.
PACKAGING SHALL BE AS PER ASTM-D-3951, MIL-STD-129R, and MIL-STD-147E.
LOT NUMBERING SHALL BE IN ACCORDANCE WITH MIL-STD-129R AND DLA Troop Support Clothing & Textiles Additional Quality Assurance Requirements dated August 2021.
File details come from the government source that posted it. Updated .