PDX 2026-518 (04) GI3.01.pdf
PDF 370 KB Posted
- Solicitation number
- 147755
- Issued by
- Multnomah County, Oregon
About this file
This is a work control plan drawing for the Portland International Airport Passenger Boarding Bridges Floor Replacement project in Oregon. The document is a technical drawing (Sheet GI3.01) dated October 2026 that illustrates the typical gate work control plan for passenger boarding bridge (PBB) floor replacement operations. The drawing provides a scaled layout of a gate area showing the aircraft parking envelope, temporary safety controls, and construction personnel access points. Key safety requirements include candlesticks positioned at maximum 8-foot intervals along the aircraft parking envelope with continuous red warning rope per Port safety requirements, red warning rope and temporary signage at the exterior stairs of the PBB restricting access to construction personnel only, and moveable stanchions with temporary signage at the holdroom door to the PBB inside the terminal. The drawing is designed for reference purposes only and indicates that the drawing scale is reduced 50 percent when printed on 11-inch by 17-inch sheet size.
The document serves as a design control and safety planning reference for construction contractors undertaking floor replacement work on the airport's passenger boarding bridges. No specific pricing, contract term, set-asides, incumbent contractor information, or funding details are provided in this technical drawing. The plan is primarily intended to guide on-site construction personnel regarding temporary safety barriers, work zones, and restricted access areas during the floor replacement project execution at Portland International Airport.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
G
NO
PARKING
BUS
ONLY
NO
PARKING
BUS
ONLY
10/23/2026 lig ht da rk gr ay bl ac k
DESIGN NUMBER PROJECT NUMBER
2"
G R
AP
H
IC
S
C
AL
E-
FO
R R
EF
ER
EN
C
E O
N
LY
gr ay
11:06:06 AMx:\pdx pbb carpet\d-drawings\00 current\gi3.01.dwg DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 11" x 17"
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
SUBMITTED BY
DRAWING NO.
1/ 4"
1/
2" 1"
BY REVISIONS APP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
NO.DATE BY REVISIONS APPNO.
TYPE:
DISC. SHT. NO.
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
A
LL
T H
R
EE
P
LA
N
ES
A R
E
VI
SI
BL
E.
T
H
IS
G U
ID
AN
C E
IS
P
R O
VI
D
ED
F
O R
R
EF
ER
EN
C E
O N
LY
D R
AW
IN
G S
C
AL
E
IS
R E
D U
C E
D
0% W
H
EN
S H
EE
T
SI
ZE
IS
1" x
7"
DATE
PORTLAND INTERNATIONAL AIRPORT
PASSENGER BOARDING BRIDGES FLOOR REPLACEMENT
WORK CONTROL PLAN - TYPICAL GATE
ERIC HEIN
D. CALEM
A. LASKEY
D. CALEM
OCTOBER 2026
04 CD
PDX 2026-518 GI3.012026D017 103105
SCALE:
WORK CONTROL PLAN - TYPICAL GATE
1" = 20'1
N
E3
LEGEND:
KEY NOTE(S) :
1. CANDLESTICKS AT 8'-0" O.C. MAX. WITH CONTINUOUS
RED WARNING ROPE PER PORT SAFETY REQUIREMENTS
ALONG AIRCRAFT PARKING ENVELOPE STRIPING -
CONFIRM EXTENTS WITH THE PORT PRIOR TO
CONSTRUCTION
2. RED WARNING ROPE AND TEMPORARY SIGNAGE AT
BOTTOM OF THE PBB EXTERIOR STAIRS STATING
"CONSTRUCTION PERSONNEL ONLY"
3. MOVEABLE STANCHIONS AND TEMPORARY SIGNAGE AT
HOLDROOM DOOR TO PBB INSIDE TERMINAL STATING
"CONSTRUCTION PERSONNEL ONLY"
EXISTING ITEM TO REMAIN
TEMPORARY CAUTION CANDLESTICKS AT
8'-0" O.C. MAX. WITH CONTINUOUS RED
CAUTION ROPE
TYP.
SCALE: IN FEET
0' 10' 20' 40' 60'
| Sheets and Views |
| GI3.01 |
| 2026-10-23T11:17:40-0700 | |
| Dave Calem |
File details come from the government source that posted it. Updated .