PAR 202511400 Technical Exhibits.pdf

PDF 2 MB Posted

Attached to
AD Project # 202511400 Massachusetts Parole Board-Bridgewater, Brockton, Randolph, or Stoughton
Solicitation number
BD-26-1019-DCP06-OOL01-129855
Issued by
Massachusetts

About this file

This is a Technical Exhibits document for the Massachusetts Department of Capital Asset Management and Maintenance (DCAMM) in support of RFP #202511400 for office space to house the Massachusetts Parole Board in Bridgewater, Brockton, Randolph, or Stoughton. The document provides detailed design standards and specifications for tenant improvements required across multiple functional areas, including a reception counter with ballistic glass protection (UL 752 Level 1 certified), perimeter shelving systems, a wellness room with sink and refrigerator, staff support spaces with water cooler and marker boards, typical office and huddle rooms, interior signage standards, and a dual-way window intercom system. The specifications detail electrical outlet placements, data connectivity requirements, ADA compliance standards, wire management infrastructure, lighting requirements, and finish materials including laminate counters, vinyl base, and paint-grade wood components. The project encompasses approximately 3,000 square feet of usable area, with DCAMM considering spaces between 2,600 and 3,400 square feet, for a 10-year lease term.

The technical exhibits establish baseline design and construction standards that contractors must meet or exceed while maintaining responsibility for code compliance and ADA accessibility throughout all improvements. Materials and equipment specifications include stainless steel deal trays (Creative Industries Model 1411-S or similar), intercom systems (Retevis RT-9908 or equivalent to be purchased by the user agency), and ADA-compliant signage manufactured by Takeform with raised text and Braille in specified typefaces and color options. All contractor work must comply with applicable building codes, and final shop drawings require approval from DCAMM prior to submittal, with the project architect responsible for verifying dimensions and overall code compliance. The exhibits function as reference standards rather than prescriptive requirements, allowing flexibility in specific design solutions while establishing the minimum technical and operational parameters for the leased space.

View the file

Other files

File Type Posted
PAR 202511400 Ten-Year Lease Proposal Form.docx DOCX document
PAR 202511400 RFP.pdf PDF
PAR 202511400 Estoppel Certificate.pdf PDF
PAR 202511400 SNDA.pdf PDF
PAR 202511400 SAFS.pdf PDF
PAR 202511400 Warning.pdf PDF
PAR 202511400 RNDA.pdf PDF
PAR 202511400 10-year Office Lease.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER

LOCATION. 18" AFF UNLESS NOTED

SYMBOL KEY

QUAD ELECTRICAL OUTLET

18" AFF UNLESS NOTED. OUTLET TO BE ALWAYS ON

2.5" GROMMETS

WM

WIRE MANAGEMENT TRAY

5' -0

10" X 12" STAINLESS STEEL DEAL TRAY PROVIDED BY

CONTRACTOR

2' -2

(3) 2.5" GROMMETS ON BOTH COUNTERS AND

THROUGH WALL FOR ELECTRIC AND DATA CORDS FOR

INTERCOM. 12" FROM TRAY . FEED INTO CABLE TRAY.

SPEAKER TO BE INSTALLED AS PER SPECS

COUNTER NOT TO PROJECT MORE THAN 4" FROM THE

WALL. AGENCY TO VALIDATE IF 12" REQUIRED AS A

WRITING SURFACE

1' -8

B

5'-0" CLEARANCE REQUIRED IN FRONT OF RECEPTION

COUNTER FOR PRIVACY

7'-0"A

WM

WM

INTERCOM

SPEAKER

2' -1

0"

WELDED

STEEL FRAME

STAINLESS STEEL DEAL TRAY

PROVIDED BY CONTRACTOR

(12"X10")

SUPPORT AS NEEDED

BALLISTIC GLASS SEE NOTES

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

BALLISTIC GLASS WINDOW

INTERCOM SYSTEM 48" AFF

M

AX

T O

P O

F C

O U

N

TE

R

4' -2

M

IN

IM

U M

G

LA

SS

H

EI

G

H T

7'-0" MINIMUM WIDTH OF GLASS

CEILING HEIGHT

VARIES

2 MINIMUM RECESSED CAN

LIGHTS OVER WORKSURFACE

GROMMET AND

INTERCOM SPEAKER

1/2" GWB OVER

BALLISTIC FIBERGLASS

ON METAL STUDDING

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL

STUDDING BOTH SIDES OF

WALL

2' -1

0"

BALLISTIC GLASS SEE

NOTES

DEAL TRAY SEE NOTES

STAFF SIDERECEPTION AREA

1/2" GWB OVER BALLISTIC

FIBERGLASS ON METAL

STUDDING BOTH SIDES OF

WALL

1'-0"

WALL TO UNDERSIDE OF

DECK1'-0"

CEILING HEIGHT PER

PROJECT SPECIFICATIONS

COUNTER SUPPORTS AS

NEEDED

PLASTIC LAMINATE

COUNTERS ON 34" PLYWOOD

SUBSTRATE. LAMINATE ON

ALL EXPOSED SURFACES.

GROMMETS TO BE PROVIDED

WIRE MANAGEMENT TRAY

2 14" EDGE BAND TO

ACOMODATE DEAL TRAY.

2 RECESSED CAN LIGHTS

MIN. OVER WORKSURFACE

WELDED STEEL FRAME, TO

MEET LEVEL 1 BALLISTICS

COUNTER SUPPORTS AS

NEEDED

NOTES FOR EXHIBIT 2.2

· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS

ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1

CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS

SHALL CONFORM TO ASTM C1036.

· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF

SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR

· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS

RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW

SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS

NOTED.

· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER

BALLISTIC FIBERGLASS ON METAL STUDS

· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK

LAPTOP AND CHANNEL FOR WIRE MANAGEMENT

· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM

AGENCY.

· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK

· 4" STRAIGHT VINYL WALL BASE THROUGH OUT

· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH

DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF

12'-0" X 8'-0"

· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION

TO BE DETERMINED BY CONTRACTOR.

· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO

SPECIFICATIONS PROVIDED BY USER AGENCY.

· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN

NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND

CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.

ARCHITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE

SCALE AS NOTED

DATE 01/14/2026

CREATED BY: BRK

CHECKED BY: JM/KH

RECEPTION COUNTER WITH BALLISTIC GLASS

TECHNICAL EXHIBIT #2.2

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS

RESPONSIBLE TO MEET APPLICABLE CODESELEVATION A SCALE 1/2" = 1'-0"SECTION BSCALE 1/2" = 1'-0"

PLAN SCALE 3/8" = 1'-0"

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 1/14/2026 10:32:43 AM

A

14"-24"

EQUAL

36" O.C. MAXEQUALEQUAL

4" PLYWOOD SUPPORTS 36"

MAX ON CENTER WITH EDGE

BLOCKING

ARCHITECT RESPONSIBLE

FOR CLEARANCE FROM

CEILING

SHELF CLEATS 1 X 3

MINIUMUM

2X 4 BLOCKING AT BASE.

ADD RUBBER BASE TO FINISH

BLOCKING REQUIRED FOR

EACH SHELF. SIZE TO BE

DETERMINED BY ARCHITECT

OR CONTRACTOR FOR

HEAVY DUTY SUPPORT

NOTES

1. TYPICAL SHELVING 14" AND 24" DEEP. TYPICAL DISTANCE

BETWEEN SHELVES 14". QUANTITY OF SHELVES TO BE

DETERMINED BY AGENCY.

2. SHOP DRAWINGS REQUIRED FOR FINAL APPROVAL.

DIMENSIONS TO BE APPROVED BY DCAMM/UA PRIOR TO

SUBMITTAL PROCESS.

3. 3/4" PLYWOOD SHELF WITH MINIMUM 14" LIP ON FRONT OF

SHELF FOR BLOCKING AND TO SECURE ITEMS ON SHELF'

4. CONTRACTOR RESPONSIBLE TO ADD BLOCKING AS NEEDED.

5. WHEN SHELVING IS BACK TO BACK PROVIDE CONSTRUCTION

GRADE 5/8" PLYWOOD THE ENTIRE LENGTH OF BACK TO

BACK SHELVING.

6. WOOD TO BE PAINT GRADE AND SEALED PRIOR TO PAINTING.

EDGE BANDING REQUIRED ON ALL PLYWOOD EDGES

NOTE DRAWING IS FOR REFERENCE ONLY

ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND CODE

COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY

WITH ADA GUIDELINES

SCALE AS NOTED

DATE 02/11/2026

CREATED BY: BRK

CHECKED BY:

PERIMETER SHELVING

TECHNICAL EXHIBIT #3

ELEVATION A

PLAN SCALE 1/4" = 1'-0"

SCALE 1/2" = 1'-0"

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/11/2026 10:29:53 AM

INTERCOM PURCHASED BY USER AGENCY. LAST UNIT

PURCHASED FROM AMAZON.COM : RETEVIS RT-9908

WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY

VOICE,WINDOW SPEAKER INTERCOM SYSTEM FOR

BUSINESS,BANK,TICKET WINDOW : ELECTRONICS

SCALE NTS

DATE 09/04/ 2025

CREATED BY: BRK

CHECKED BY:

DUAL WAY WINDOW INTERCOM SYSTEM

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE

TECHNICAL EXHIBIT # 9

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 9/5/2025 3:02:57 PM

42 AFF

MINUMUM

TABLE

1'-6"

CLEAR

RESILIENT

FLOORING

CARPET

2'

-1 0"

8'-0"

REFRIGERATOR

NIC

34" MINIMUM WIDTH AND

24" MINIMUM HEIGHT

CLEARANCE. 17" KNEE

SPACE MINIMUM.

3' -6

S

EC

TI

O

N A

1' -6

2' -3

2' -1

0"

1'-5"

9"

REMOVABLE

PANEL

ROOMS WITH PLUMBING: KITCHEN / WELLNESS

DUPLEX ELECTRICAL

OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER

OUTLETS PER

LOCATION

WELLNESS ROOM NOTES

· FURNITURE SHOWN TO BE PROVIDED BY TENANT

· LIGHTS TO BE DIMMABLE

· FLOORING AT SINK TO BE RESILIENT FLOORING

· IF SIDE LIGHT PROVIDED ENTIRE WINDOW TO BE

PRIVACY FILM

· MIRROR & BULLETIN BOARD NOT PROVIDED BY

CONTRACTOR

WELLNESS ROOM

TECHNICAL EXHIBIT #13

PLAN TYPICAL 80 SQ FT

SCALE 1/2" =1'-0"

SCALE 1/4" = 1'-0"

SCALE as noted

DATE 10/07/2025

CREATED BY: BK

CHECKED BY : CB and EA

SINK SECTION SCALE 1/2" = 1'-0"

ELEVATION OF MILLWORK WELLNESS ROOM

EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/7/2025 3:17:15 PM

AutoCAD SHX Text

REF

2' -1

0"3' -6

1' -6

2'-0" 1'-6"3'-0"

1' -3

2'

-6

3'-0"

24" MINIMUM HEIGHT

CLEARANCE. 17" KNEE

SPACE MINIMUM.

S

EC

TI

O

N A

1'-6"

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

DATA OUTLETS. 2 PER OUTLETS PER LOCATION

H20

MARKER BOARD AND/OR

TACK BOARD TBD

8' -0

"C H

C H

C

H 07C

H

42"

AFF

42"

AFF

QUENCH WATER COOLER

AND WALL PHONE TBD

A

MARKER BOARD AND

TACK BOARD ALIGN

BOTTOM

WITH COUNTER

30 x 60

30 x 60

30 x 60

A

42"

AFF

42"

AFF

H20

WALL PHONE TBD

QUENCH WATER COOLER

2' -3

2' -1

0"

1'-5"

9"

REMOVABLE

PANEL

SCALE AS NOTED

DATE 06/06/2025

CREATED BY: BRK

CHECKED BY: CB

STAFF SUPPORT

TECHNICAL EXHIBIT #14

ELEVATION A OF MILLWORK STAFF SUPPORT ROOM

PLAN KEY

SCALE 1/2" =1'-0"

SCALE 1/4" =1'-0"TYPICAL PLAN 200 SQ FT STAFF SUPPORT SPACE

SCALE 1/4" =1'-0"TYPICAL PLAN 400 SQ FT STAFF SUPPORT SPACE

NOTES

PLANS SHOW PREFERRED OPTION FOR QUENCH WATER COOLERS BY MOST AGENCIES . VALIDATE

LOCATION WITH AGENCY. SOME AGENCIES PREFER COUNTER TOP OPTIONS WHEN SPACE PERMITS

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE

SINK SECTION A SCALE 1/2" = 1'-0"

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 6/3/2025 5:06:37 PM

AutoCAD SHX Text

REFRIGERATOR NIC

WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT

SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR (AFF) MEASURED TO THE BASELINE OF THE RAISED TEXT.

· THE ABOVE RECOMMENDED PLACEMENT IS INTENDED TO MEET THE SIGN LOCATION REQUIREMENTS OF THE 2010 ADA

STANDARDS. SEC.703.4.1

· SIGN ALIGNMENT TO BE MOUNTED ON SURFACE ADJACENT TO THE LATCH SIDE OF THE DOOR, WITHIN 2" - 4" FROM THE

DOOR TRIM.

Conference

Conference

Conference

PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL

SIGN 2" - 4" FROM FRAME

5' -4

1' -1

0"

1'-4"

ROOM ID SIGNAGEGLAZING FILM

1/4" TEMPERED GLAZING

1'-6"

R

AI

SE

D

T

EX

T

" A

FF

R

AI

SE

D

T

EX

T

" A

FF

R

AI

SE

D

T

EX

T

" A

FF

SIGN 2" - 4" FROM FRAME SIGN 2" - 4" FROM FRAME

1'-4"

1'-6"

1' -1

0" 3'

-6

3' -6

INTERIOR SIGNAGE STANDARDS

NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.

CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.

SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND

SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.

TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER

CMYK 8,9,5,35

TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01

THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE

SIGNS

GLAZING FILM: 3M CRYSTAL, DUSTED (7725SE-314) OR EQUAL

· GLAZING FILM TO BE INSTALLED ON THE ROOM SIDE OF THE GLAZING USING MANUFACTURER APPROVED

PRODUCTS AND INSTALLATION INSTRUCTIONS. GLASS DOORS TO HAVE MATCHING FILM

· A MANUFACTURER APPROVED SIGNAGE BACKER SHALL BE MOUNTED ON THE ROOM SIDE OF THE GLAZING

DIRECTLY BEHIND THE ROOM ID SIGNAGE. THE BACKER SHALL BE SIMILAR SIZE TO THE ROOM ID SIGNAGE SO THAT IT FULLY COVER THE BACK OF THE SIGNAGE. IF GLAZING FILM IS SPECIFIED, THE SIGNAGE BACKER

SHALL BE MOUNTED ON TOP OF THE GLAZING FILM.

Conference

TYPICAL WORKSTATION SIGNS

5"W X 3.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED

TYPICAL OFFICE SIGNS

CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS

5"W X 5.5"H WITH INSERT

MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER

DEPENDING ON WORKSTATIONS SPECIFIED.

ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT

TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.

W5209.05

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

OPTIONS FOR BACKGROUND

PMS 539C DARK BLUE

OR SILVER

GRAPHIC PRINTED ON INSERT

WINDOW SIZE 4.5W X 2.5 H

TECHNICAL EXHIBIT #15

SIGNAGE FOR LEASING PROJECTS

SCALE AS NOTED

DATE 06/06/ 2025

CREATED BY: BK

CHECKED BY: AB

NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES

DETAILS SCALE 6" = 1'-0"

ELEVATIONS SCALE 1/8" = 1'-0"

NOTES

T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/12/2026 10:24:32 AM

CH-O

10'-0"

'-0

TB

D

8W

30x72

6' -0

" C H

-O

10'-0"

'-0

TBD 48W

30x72

6' -0

4' -0

4' -0

MINIMUM 9'-0"

DUPLEX ELECTRICAL OUTLET

18" AFF UNLESS NOTED

QUAD ELECTRICAL OUTLET 18" AFF

UNLESS NOTED. OUTLETS TO BE ALWAYS

ON.

DATA OUTLETS. 2 PER OUTLETS

PER LOCATION

10'-0"

'-0

TABLE

36x72

3'-0" MIN.

5' -0

CH-O

10'-0"

5' -0

'-0

TB

D

8W

30x72

5' -0

5' -0

MONITORS ON ARMS

OR MOUNTED TO WALL

WITH HDMI FOR

MONITOR CONNECTED

TO DOCKING STATION

ON TABLE

TYPICAL OFFICE 100 SQ FT

SCALE 1/4" = 1'- 0"

DATE 10/07/ 2025

CREATED BY: BRK

CHECKED BY: JW

TYPICAL OFFICE AND HUDDLE ROOMS

TECHNICAL EXHIBIT #17

TYPICAL OFFICE 120 SQ FT TYPICAL FLEX OFFICE OR HUDDLE 120 SQ FT

NOTES

· OUTLETS SHOWN ARE TO BE ALWAYS ON.

· SWITCHED OUTLETS TO BE CLEARLY NOTED

· MONITOR ARMS ARE SELECTED BY USER

AGENCY.

EXHIBITS ARE FOR REFERENCE ONLY.

CONTRACTOR IS RESPONSIBLE TO MEET

APPLICABLE CODES INCLUDING ADA COMPLIANCE

T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/16/2025 4:21:22 PM

Technical Exhibit 2.2 Typical Transaction Transaction Counter (Ballistic Glass)
Sheets and Views
TE2.2 Ballistic
Technical Exhibit 3- Perimeter Shelving
Sheets and Views
TE3 Shelving
Technical Exhibit 9- Dual Way Window Intercom System
Sheets and Views
Intercom TE 9
Technical Exhibit 13 Wellness Room
Sheets and Views
WELLNESS TE13
Technical Exhibit 14 Staff Support]
Sheets and Views
STAFF SUP. TE 14
Technical Exhibit 15 Signage
Sheets and Views
TE15 Signage
Technical Exhibit 17 Typical Office and Huddle
Sheets and Views
OFFICE HUDDLE TE17

File details come from the government source that posted it. Updated .