This is a Technical Exhibits document for the Massachusetts Department of Capital Asset Management and Maintenance (DCAMM) in support of RFP #202511400 for office space to house the Massachusetts Parole Board in Bridgewater, Brockton, Randolph, or Stoughton. The document provides detailed design standards and specifications for tenant improvements required across multiple functional areas, including a reception counter with ballistic glass protection (UL 752 Level 1 certified), perimeter shelving systems, a wellness room with sink and refrigerator, staff support spaces with water cooler and marker boards, typical office and huddle rooms, interior signage standards, and a dual-way window intercom system. The specifications detail electrical outlet placements, data connectivity requirements, ADA compliance standards, wire management infrastructure, lighting requirements, and finish materials including laminate counters, vinyl base, and paint-grade wood components. The project encompasses approximately 3,000 square feet of usable area, with DCAMM considering spaces between 2,600 and 3,400 square feet, for a 10-year lease term.
The technical exhibits establish baseline design and construction standards that contractors must meet or exceed while maintaining responsibility for code compliance and ADA accessibility throughout all improvements. Materials and equipment specifications include stainless steel deal trays (Creative Industries Model 1411-S or similar), intercom systems (Retevis RT-9908 or equivalent to be purchased by the user agency), and ADA-compliant signage manufactured by Takeform with raised text and Braille in specified typefaces and color options. All contractor work must comply with applicable building codes, and final shop drawings require approval from DCAMM prior to submittal, with the project architect responsible for verifying dimensions and overall code compliance. The exhibits function as reference standards rather than prescriptive requirements, allowing flexibility in specific design solutions while establishing the minimum technical and operational parameters for the leased space.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| PAR 202511400 Ten-Year Lease Proposal Form.docx | DOCX document | |
| PAR 202511400 RFP.pdf | ||
| PAR 202511400 Estoppel Certificate.pdf | ||
| PAR 202511400 SNDA.pdf | ||
| PAR 202511400 SAFS.pdf | ||
| PAR 202511400 Warning.pdf | ||
| PAR 202511400 RNDA.pdf | ||
| PAR 202511400 10-year Office Lease.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER
LOCATION. 18" AFF UNLESS NOTED
SYMBOL KEY
QUAD ELECTRICAL OUTLET
18" AFF UNLESS NOTED. OUTLET TO BE ALWAYS ON
2.5" GROMMETS
WM
WIRE MANAGEMENT TRAY
5' -0
10" X 12" STAINLESS STEEL DEAL TRAY PROVIDED BY
CONTRACTOR
2' -2
(3) 2.5" GROMMETS ON BOTH COUNTERS AND
THROUGH WALL FOR ELECTRIC AND DATA CORDS FOR
INTERCOM. 12" FROM TRAY . FEED INTO CABLE TRAY.
SPEAKER TO BE INSTALLED AS PER SPECS
COUNTER NOT TO PROJECT MORE THAN 4" FROM THE
WALL. AGENCY TO VALIDATE IF 12" REQUIRED AS A
WRITING SURFACE
1' -8
B
5'-0" CLEARANCE REQUIRED IN FRONT OF RECEPTION
COUNTER FOR PRIVACY
7'-0"A
WM
WM
INTERCOM
SPEAKER
2' -1
0"
WELDED
STEEL FRAME
STAINLESS STEEL DEAL TRAY
PROVIDED BY CONTRACTOR
(12"X10")
SUPPORT AS NEEDED
BALLISTIC GLASS SEE NOTES
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
BALLISTIC GLASS WINDOW
INTERCOM SYSTEM 48" AFF
M
AX
T O
P O
F C
O U
N
TE
R
4' -2
M
IN
IM
U M
G
LA
SS
H
EI
G
H T
7'-0" MINIMUM WIDTH OF GLASS
CEILING HEIGHT
VARIES
2 MINIMUM RECESSED CAN
LIGHTS OVER WORKSURFACE
GROMMET AND
INTERCOM SPEAKER
1/2" GWB OVER
BALLISTIC FIBERGLASS
ON METAL STUDDING
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL
STUDDING BOTH SIDES OF
WALL
2' -1
0"
BALLISTIC GLASS SEE
NOTES
DEAL TRAY SEE NOTES
STAFF SIDERECEPTION AREA
1/2" GWB OVER BALLISTIC
FIBERGLASS ON METAL
STUDDING BOTH SIDES OF
WALL
1'-0"
WALL TO UNDERSIDE OF
DECK1'-0"
CEILING HEIGHT PER
PROJECT SPECIFICATIONS
COUNTER SUPPORTS AS
NEEDED
PLASTIC LAMINATE
COUNTERS ON 34" PLYWOOD
SUBSTRATE. LAMINATE ON
ALL EXPOSED SURFACES.
GROMMETS TO BE PROVIDED
WIRE MANAGEMENT TRAY
2 14" EDGE BAND TO
ACOMODATE DEAL TRAY.
2 RECESSED CAN LIGHTS
MIN. OVER WORKSURFACE
WELDED STEEL FRAME, TO
MEET LEVEL 1 BALLISTICS
COUNTER SUPPORTS AS
NEEDED
NOTES FOR EXHIBIT 2.2
· GLASS IN WINDOW TO BE UL 752 LEVEL 1 BALLISTIC RESISTANT LAMINATED GLASS
ASSEMBLY, CONSTRUCTED PER ASTM C1172, AND COMPLIANT WITH ANSI Z97.1
CLASS A AND CPSC 16 CFR 1201 CATEGORY II, AS APPLICABLE. SAFETY GLASS
SHALL CONFORM TO ASTM C1036.
· DEAL TRAY STAINLESS STEEL 12 X 10 DROP IN MODEL TO ALLOW TRANSFER OF
SMALL ITEMS. CREATIVE INDUSTRIES MODEL1411-S OR SIMILAR
· INTERCOM SYSTEM TO BE PROVIDED BY USER AGENCY. SIMILAR TO RETEVIS
RT-9908 WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY VOICE,WINDOW
SPEAKER INTERCOM SYSTEM. OUTLET, AND 3 GROMMETS TO BE PROVIDED AS
NOTED.
· BOTH SIDES OF WALL BETWEEN AGENCY AND PUBLIC TO BE 1/2" GWB OVER
BALLISTIC FIBERGLASS ON METAL STUDS
· COUNTER DEPTH MINIMUM 12" EACH SIDE. SUPPORTS TO HAVE HOLE TO LOCK
LAPTOP AND CHANNEL FOR WIRE MANAGEMENT
· COUNTER FINISH TO BE SELECTED BY PROJECT ARCHITECT WITH APPROVAL FROM
AGENCY.
· WALL WITH TRANSACTION COUNTER AND GLASS TO DECK
· 4" STRAIGHT VINYL WALL BASE THROUGH OUT
· IF DOOR HAS DOOR CLOSER ROOM IS REQUIRED TO BE 6" LONGER, FOR EACH
DOOR. IF BOTH DOORS HAVE CLOSER ROOM WOULD NEED TO BE MINIMUM OF
12'-0" X 8'-0"
· NOTE DRAWING FOR REFERENCE DETAILS ON GLASS FRAME AND CONFIGURATION
TO BE DETERMINED BY CONTRACTOR.
· DATA JACK FOR ETHERNET CABLE TO BE PATCHED ACCORDING TO
SPECIFICATIONS PROVIDED BY USER AGENCY.
· WIRE MANAGEMENT TRAY TO BE INCLUDED AS SHOWN
NOTE DRAWING IS FOR REFERENCE ONLY ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND
CODE COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY WITH ADA GUIDELINES.
ARCHITECT IS RESPONSIBLE TO CONFIRM THAT ADA ROOM MEETS COMPLIANCE
SCALE AS NOTED
DATE 01/14/2026
CREATED BY: BRK
CHECKED BY: JM/KH
RECEPTION COUNTER WITH BALLISTIC GLASS
TECHNICAL EXHIBIT #2.2
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS
RESPONSIBLE TO MEET APPLICABLE CODESELEVATION A SCALE 1/2" = 1'-0"SECTION BSCALE 1/2" = 1'-0"
PLAN SCALE 3/8" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 1/14/2026 10:32:43 AM
A
14"-24"
EQUAL
36" O.C. MAXEQUALEQUAL
4" PLYWOOD SUPPORTS 36"
MAX ON CENTER WITH EDGE
BLOCKING
ARCHITECT RESPONSIBLE
FOR CLEARANCE FROM
CEILING
SHELF CLEATS 1 X 3
MINIUMUM
2X 4 BLOCKING AT BASE.
ADD RUBBER BASE TO FINISH
BLOCKING REQUIRED FOR
EACH SHELF. SIZE TO BE
DETERMINED BY ARCHITECT
OR CONTRACTOR FOR
HEAVY DUTY SUPPORT
NOTES
1. TYPICAL SHELVING 14" AND 24" DEEP. TYPICAL DISTANCE
BETWEEN SHELVES 14". QUANTITY OF SHELVES TO BE
DETERMINED BY AGENCY.
2. SHOP DRAWINGS REQUIRED FOR FINAL APPROVAL.
DIMENSIONS TO BE APPROVED BY DCAMM/UA PRIOR TO
SUBMITTAL PROCESS.
3. 3/4" PLYWOOD SHELF WITH MINIMUM 14" LIP ON FRONT OF
SHELF FOR BLOCKING AND TO SECURE ITEMS ON SHELF'
4. CONTRACTOR RESPONSIBLE TO ADD BLOCKING AS NEEDED.
5. WHEN SHELVING IS BACK TO BACK PROVIDE CONSTRUCTION
GRADE 5/8" PLYWOOD THE ENTIRE LENGTH OF BACK TO
BACK SHELVING.
6. WOOD TO BE PAINT GRADE AND SEALED PRIOR TO PAINTING.
EDGE BANDING REQUIRED ON ALL PLYWOOD EDGES
NOTE DRAWING IS FOR REFERENCE ONLY
ARCHITECT IS RESPONSIBLE TO VERIFY DIMENSIONS AND CODE
COMPLIANCE. ALL GOVERNMENT PROPERTIES ARE TO COMPLY
WITH ADA GUIDELINES
SCALE AS NOTED
DATE 02/11/2026
CREATED BY: BRK
CHECKED BY:
PERIMETER SHELVING
TECHNICAL EXHIBIT #3
ELEVATION A
PLAN SCALE 1/4" = 1'-0"
SCALE 1/2" = 1'-0"
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/11/2026 10:29:53 AM
INTERCOM PURCHASED BY USER AGENCY. LAST UNIT
PURCHASED FROM AMAZON.COM : RETEVIS RT-9908
WINDOW SPEAKER,WINDOW INTERCOM DUAL-WAY
VOICE,WINDOW SPEAKER INTERCOM SYSTEM FOR
BUSINESS,BANK,TICKET WINDOW : ELECTRONICS
SCALE NTS
DATE 09/04/ 2025
CREATED BY: BRK
CHECKED BY:
DUAL WAY WINDOW INTERCOM SYSTEM
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
TECHNICAL EXHIBIT # 9
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 9/5/2025 3:02:57 PM
42 AFF
MINUMUM
TABLE
1'-6"
CLEAR
RESILIENT
FLOORING
CARPET
2'
-1 0"
8'-0"
REFRIGERATOR
NIC
34" MINIMUM WIDTH AND
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
3' -6
S
EC
TI
O
N A
1' -6
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
ROOMS WITH PLUMBING: KITCHEN / WELLNESS
DUPLEX ELECTRICAL
OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER
OUTLETS PER
LOCATION
WELLNESS ROOM NOTES
· FURNITURE SHOWN TO BE PROVIDED BY TENANT
· LIGHTS TO BE DIMMABLE
· FLOORING AT SINK TO BE RESILIENT FLOORING
· IF SIDE LIGHT PROVIDED ENTIRE WINDOW TO BE
PRIVACY FILM
· MIRROR & BULLETIN BOARD NOT PROVIDED BY
CONTRACTOR
WELLNESS ROOM
TECHNICAL EXHIBIT #13
PLAN TYPICAL 80 SQ FT
SCALE 1/2" =1'-0"
SCALE 1/4" = 1'-0"
SCALE as noted
DATE 10/07/2025
CREATED BY: BK
CHECKED BY : CB and EA
SINK SECTION SCALE 1/2" = 1'-0"
ELEVATION OF MILLWORK WELLNESS ROOM
EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/7/2025 3:17:15 PM
AutoCAD SHX Text
REF
2' -1
0"3' -6
1' -6
2'-0" 1'-6"3'-0"
1' -3
2'
-6
3'-0"
24" MINIMUM HEIGHT
CLEARANCE. 17" KNEE
SPACE MINIMUM.
S
EC
TI
O
N A
1'-6"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
DATA OUTLETS. 2 PER OUTLETS PER LOCATION
H20
MARKER BOARD AND/OR
TACK BOARD TBD
8' -0
"C H
C H
C
H 07C
H
42"
AFF
42"
AFF
QUENCH WATER COOLER
AND WALL PHONE TBD
A
MARKER BOARD AND
TACK BOARD ALIGN
BOTTOM
WITH COUNTER
30 x 60
30 x 60
30 x 60
A
42"
AFF
42"
AFF
H20
WALL PHONE TBD
QUENCH WATER COOLER
2' -3
2' -1
0"
1'-5"
9"
REMOVABLE
PANEL
SCALE AS NOTED
DATE 06/06/2025
CREATED BY: BRK
CHECKED BY: CB
STAFF SUPPORT
TECHNICAL EXHIBIT #14
ELEVATION A OF MILLWORK STAFF SUPPORT ROOM
PLAN KEY
SCALE 1/2" =1'-0"
SCALE 1/4" =1'-0"TYPICAL PLAN 200 SQ FT STAFF SUPPORT SPACE
SCALE 1/4" =1'-0"TYPICAL PLAN 400 SQ FT STAFF SUPPORT SPACE
NOTES
PLANS SHOW PREFERRED OPTION FOR QUENCH WATER COOLERS BY MOST AGENCIES . VALIDATE
LOCATION WITH AGENCY. SOME AGENCIES PREFER COUNTER TOP OPTIONS WHEN SPACE PERMITS
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES INCLUDING ADA COMPLIANCE
SINK SECTION A SCALE 1/2" = 1'-0"
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 6/3/2025 5:06:37 PM
AutoCAD SHX Text
REFRIGERATOR NIC
WALL WITH SIDELIGHT WALL AND SIDELIGHTWALL WITH NO SIDELIGHT
SIGNAGE - INSTALLATION FOR PERMANENT IDENTIFICATION OF WALLED SPACES (WALL/GLASS) MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR (AFF) MEASURED TO THE BASELINE OF THE RAISED TEXT.
· THE ABOVE RECOMMENDED PLACEMENT IS INTENDED TO MEET THE SIGN LOCATION REQUIREMENTS OF THE 2010 ADA
STANDARDS. SEC.703.4.1
· SIGN ALIGNMENT TO BE MOUNTED ON SURFACE ADJACENT TO THE LATCH SIDE OF THE DOOR, WITHIN 2" - 4" FROM THE
DOOR TRIM.
Conference
Conference
Conference
PLACE SIGN ON SIDELIGHT PLACE SIGN ON WALL PLACE SIGN ON WALL
SIGN 2" - 4" FROM FRAME
5' -4
1' -1
0"
1'-4"
ROOM ID SIGNAGEGLAZING FILM
1/4" TEMPERED GLAZING
1'-6"
R
AI
SE
D
T
EX
T
" A
FF
R
AI
SE
D
T
EX
T
" A
FF
R
AI
SE
D
T
EX
T
" A
FF
SIGN 2" - 4" FROM FRAME SIGN 2" - 4" FROM FRAME
1'-4"
1'-6"
1' -1
0" 3'
-6
3' -6
INTERIOR SIGNAGE STANDARDS
NOTE BACKERS REQUIRED WHEN MOUNTED ON GLASS. BACKER COLOR TO BE CONFIRMED BY AGENCY.
CONTRACTOR RESPONSIBLE TO MEET ADA COMPLIANCE ON ALL SIGNS. INCLUDING INSTALLATION.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE AND DRAWINGS ABOVE. INSERT TEXT TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS. ALL SIGNS TO BE POSTED BY CONTRACTOR. ADDITIONAL MATERIAL AND PRINTING INSTRUCTIONS TO BE SUPPLIED TO AGENCY FOR FUTURE SIGNS.
SIGNS CAN BE PURCHASED THROUGH TAKEFORM STYLE VIVID (TAKEFORM.NET). ORDERS AND QUESTIONS CAN BE PLACED BY EMAILING MIKE R. HUNGERFORD 1.800.528.1398 MRH@TAKEFORM.NET. FINAL SIGNAGE OPTIONS AND
SIGNS TO BE SUBMITTED TO DCAMM PROJECT MANGER FOR APPROVAL.
TAKEFORM ROOM SIGNS ARE TYPE J.3B VVAW-01001105-R9DO1. TAKEFORM COLROS DARK BLUE PMS 539C OR SILVER
CMYK 8,9,5,35
TAKEFORM WORKSATION SIGNS ARE TYPE L.b VV1AW-01000701-R9D01
THIS IS FOR INTERNAL AGENCY SPACE ONLY. THESE SIGNS ARE NOT APPLICABLE FOR BATHROOM OR BUILDING CORE
SIGNS
GLAZING FILM: 3M CRYSTAL, DUSTED (7725SE-314) OR EQUAL
· GLAZING FILM TO BE INSTALLED ON THE ROOM SIDE OF THE GLAZING USING MANUFACTURER APPROVED
PRODUCTS AND INSTALLATION INSTRUCTIONS. GLASS DOORS TO HAVE MATCHING FILM
· A MANUFACTURER APPROVED SIGNAGE BACKER SHALL BE MOUNTED ON THE ROOM SIDE OF THE GLAZING
DIRECTLY BEHIND THE ROOM ID SIGNAGE. THE BACKER SHALL BE SIMILAR SIZE TO THE ROOM ID SIGNAGE SO THAT IT FULLY COVER THE BACK OF THE SIGNAGE. IF GLAZING FILM IS SPECIFIED, THE SIGNAGE BACKER
SHALL BE MOUNTED ON TOP OF THE GLAZING FILM.
Conference
TYPICAL WORKSTATION SIGNS
5"W X 3.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED
TYPICAL OFFICE SIGNS
CONFERENCE, OFFICES, FOCUS ROOMS, PHONE ROOMS, HUDDLE ROOMS
5"W X 5.5"H WITH INSERT
MOUNTED WITH MAGNET, PIN OR CUBICLE HANGER
DEPENDING ON WORKSTATIONS SPECIFIED.
ROOM NUMBERS MUST BE RENDERED IN RAISED COPY WITH BRAILLE PER CODE. INSERT TEXT
TO BE APTOS FONT PRINTED ON POLYESTER MEDIA PER DRAWINGS AND CALLOUTS.
W5209.05
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
OPTIONS FOR BACKGROUND
PMS 539C DARK BLUE
OR SILVER
GRAPHIC PRINTED ON INSERT
WINDOW SIZE 4.5W X 2.5 H
TECHNICAL EXHIBIT #15
SIGNAGE FOR LEASING PROJECTS
SCALE AS NOTED
DATE 06/06/ 2025
CREATED BY: BK
CHECKED BY: AB
NOTE EXHIBITS ARE FOR REFERENCE ONLY. CONTRACTOR IS RESPONSIBLE TO MEET APPLICABLE CODES
DETAILS SCALE 6" = 1'-0"
ELEVATIONS SCALE 1/8" = 1'-0"
NOTES
T:\Projects\_LEASING EXHIBIT UPDATES\2.0 Design-Drawings\Working\LEASING EXHIBITS_UPDATE 2026.dwg, 2/12/2026 10:24:32 AM
CH-O
10'-0"
'-0
TB
D
8W
30x72
6' -0
" C H
-O
10'-0"
'-0
TBD 48W
30x72
6' -0
4' -0
4' -0
MINIMUM 9'-0"
DUPLEX ELECTRICAL OUTLET
18" AFF UNLESS NOTED
QUAD ELECTRICAL OUTLET 18" AFF
UNLESS NOTED. OUTLETS TO BE ALWAYS
ON.
DATA OUTLETS. 2 PER OUTLETS
PER LOCATION
10'-0"
'-0
TABLE
36x72
3'-0" MIN.
5' -0
CH-O
10'-0"
5' -0
'-0
TB
D
8W
30x72
5' -0
5' -0
MONITORS ON ARMS
OR MOUNTED TO WALL
WITH HDMI FOR
MONITOR CONNECTED
TO DOCKING STATION
ON TABLE
TYPICAL OFFICE 100 SQ FT
SCALE 1/4" = 1'- 0"
DATE 10/07/ 2025
CREATED BY: BRK
CHECKED BY: JW
TYPICAL OFFICE AND HUDDLE ROOMS
TECHNICAL EXHIBIT #17
TYPICAL OFFICE 120 SQ FT TYPICAL FLEX OFFICE OR HUDDLE 120 SQ FT
NOTES
· OUTLETS SHOWN ARE TO BE ALWAYS ON.
· SWITCHED OUTLETS TO BE CLEARLY NOTED
· MONITOR ARMS ARE SELECTED BY USER
AGENCY.
EXHIBITS ARE FOR REFERENCE ONLY.
CONTRACTOR IS RESPONSIBLE TO MEET
APPLICABLE CODES INCLUDING ADA COMPLIANCE
T:\Administrative\Boiler Plate\Leasing\2.0 Design-Drawings\CAD\LEASING SPACE STANDARDS.dwg, 10/16/2025 4:21:22 PM
| Technical Exhibit 2.2 Typical Transaction Transaction Counter (Ballistic Glass) |
| Sheets and Views |
| TE2.2 Ballistic |
| Technical Exhibit 3- Perimeter Shelving |
| Sheets and Views |
| TE3 Shelving |
| Technical Exhibit 9- Dual Way Window Intercom System |
| Sheets and Views |
| Intercom TE 9 |
| Technical Exhibit 13 Wellness Room |
| Sheets and Views |
| WELLNESS TE13 |
| Technical Exhibit 14 Staff Support] |
| Sheets and Views |
| STAFF SUP. TE 14 |
| Technical Exhibit 15 Signage |
| Sheets and Views |
| TE15 Signage |
| Technical Exhibit 17 Typical Office and Huddle |
| Sheets and Views |
| OFFICE HUDDLE TE17 |
File details come from the government source that posted it. Updated .