P530 AIMF_PLANS_DRAFT_20250728_Part1.pdf
PDF 20 MB Posted
- Solicitation number
- W912HV26Z0007
About this file
These documents are 65% design submittal drawings for a P530 Aircraft Intermediate Maintenance Facility project for the US Army Corps of Engineers Japan District, located at Kadena Air Base in Okinawa, Japan. The project involves constructing a two-story maintenance facility with comprehensive architectural, structural, mechanical, electrical, telecommunications, and fire protection design plans. Key design features include multiple specialized areas for maintenance and production control, comprehensive life safety systems, fire protection measures meeting US testing standards, and detailed specifications for building systems across electrical, plumbing, mechanical, and telecommunications domains. The project is scheduled for July 2025 and involves multiple consulting firms including Woolpert (architecture and engineering), Crawford Consulting (cost estimating), and ESC (geotechnical and site survey). The design drawings include extensive technical details covering everything from building layout and occupant load to fire suppression, exit routes, and equipment specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
O U
N T
A
IN
S P
A R
K W
A Y
S U
IT
E
F A
IR
V
IE
W
H E
IG
H
T S
I
L
-2
.6
.7
W O
O L
P E
R T
In c
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
Q K
K A
H A
B D
E L A
Z
IZ
H A
B D
E L A
Z
IZ
R K
N O
L L E
M L O
H S
E
D
E S
IG
N
S U
B M
IT
T
A L
G-001
C O
V E
R S
H E
E T
C O
M F
L E
A C
T O
K
IN
A W
A J
A K
A D
E N
A A
F B
O
K
IN
A W
A J A
P A
N
P A
IR
C
R A
F T
I N
T E
R M
E D
IA
T
E M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
W H
V D
J A
P A
N D
IS
T
R
IC
T U n it
A P
O A
P
-5
J U
L Y
W H
V D
G
-0
OKINAWA CITY
KADENA CITY
KADENA AIR BASE
58 329
ENGINEERING DIVISION
US ARMY ENGINEER DISTRICT, JAPAN
P530 - AIRCRAFT INTERMEDIATE
MAINTENANCE FACILITY
KADENA AIR BASE, JAPAN
PROJECT TEAM
Architecture and Engineering:
Woolpert 343 Fountains Parkway, Suite 100 Fairview Heights, IL 62208 tel: (618) 632-7004
Cost Estimating:
Crawford Consulting 239 Highland Avenue East Pittsburgh, PA 15112 tel: (412) 823-0400 / fax: (412) 823-2004
SEAL:
LOCATION MAP
PREPARED BY U.S. ARMY ENGINEER DISTRICT, JAPAN
U.S. ARMY ENGINEER DISTRICT, JAPAN
PROJECT MANAGER DATE
CHIEF, ENGINEER BRANCH DATE
THIS PROJECT WAS DESIGNED BY JAPAN DISTRICT OF THE U.S. ARMY CORPS OF ENGINEERS. THE INITIALS OR SIGNATURES AND REGISRTATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS
REQUIRED BY ER 1110-1-8152.
CIVIL STRUCTURAL FIRE PROTECTION MECHANICAL ELECTRICALPLUMBING COMMUNICATIONS
(NAME AND LICENSE)
Project Number: XXX Solicitation Number: XXX
Contract Number: XXX
VICINITY MAP
Geotechnical and Site Survey:
ESC (Enviromental Science Corportation) ESC Building 1553-231 Ishikawa Iha Uruma City, Okinawa, Japan 904-1115 tel: (+81) 98-989-0426
ARCHITECTURAL
(NAME AND LICENSE)(NAME AND LICENSE)(NAME AND LICENSE)(NAME AND LICENSE)(NAME AND LICENSE)(NAME AND LICENSE)(NAME AND LICENSE)
YOKOTA AB
HOKKAIDO
MISAWA AB
NAF ATSUGI
YOKOSUKA NP
IKEGO
IWO JIMA
KADENA AB
PROJECT SITE
OKINAWA
KYUSHU
SASEBO NB
MCAS IWAKUNI
CAMP FUJI
CAMP ZAMA
SAGAMIHARA HOUSING
AREA SAGAMI GENERAL
DEPOT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
DRAFT
F
O U
N T
A
IN
S P
A R
K W
A Y
S U
IT
E
F A
IR
V
IE
W
H E
IG
H
T S
I
L
-2
.6
.7
W O
O L
P E
R T
In c
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
C H
E C
K E
D B
Y
US Army Corps of Engineers ®
IS
O
A
A
D R
A W
IN
G
C O
D E
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
Q K
K A
H A
B D
E L A
Z
IZ
H A
B D
E L A
Z
IZ
R K
N O
L L E
M L O
H S
E
D
E S
IG
N
S U
B M
IT
T
A L
G-002
S H
E E
T I
N D
E X
C O
M F
L E
A C
T O
K
IN
A W
A J
A K
A D
E N
A A
F B
O
K
IN
A W
A J A
P A
N
P A
IR
C
R A
F T
I N
T E
R M
E D
IA
T
E M
A
IN
T E
N A
N C
E F
A C
IL
IT
Y
W H
V D
J A
P A
N D
IS
T
R
IC
T U n it
A P
O A
P
-5
J U
L Y
W H
V D
G
-0
SHEET INDEX
SHEET
NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
G-003 HAUL ROUTE, SITE LOCATION, AND VICINITY MAPS
LIFE SAFETY
GI001 CODE SUMMARY SHEET
GI101 FIRST FLOOR LIFE SAFETY PLAN
GI102 SECOND FLOOR LIFE SAFETY PLAN
GEOTECHNICAL
B-101 BORING LOCATION MAP
B-102 BORING LOGS
B-103 BORING LOGS
SURVEY / MAPPING
V-100 OVERALL EXISTING CONDITIONS
V-101 EXISTING CONDITIONS
V-102 EXISTING CONDITIONS
CIVIL
C-001 LEGEND
CD101 DEMOLITION PLAN
CD102 DEMOLITION PLAN
CS101 SITE PLAN
CS102 SITE PLAN
CS103 GEOMETRIC PLAN
CS104 GEOMETRIC PLAN
CS105 GEOMETRIC POINT TABLE
CJ101 JOINTING PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CS503 SITE DETAILS
SHEET INDEX
SHEET
NUMBER SHEET NAME
ELECTRICAL
E-001 ELECTRICAL LEGENDS
ES001 ELECTRICAL SITE PLAN
ES002 ELECTRICAL SITE PLAN PHOTOMETRICS
E-101 ELECTRICAL FIRST FLOOR OVERALL LIGHTING PLAN
E-101A ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA A
E-101B ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA B
E-101C ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA C
E-101D ELECTRICAL FIRST FLOOR LIGHTING PLAN - AREA D
E-102 ELECTRICAL SECOND FLOOR OVERALL LIGHTING PLAN
E-102A ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREA A
E-102B ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREA B
E-102C ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREA C
E-102D ELECTRICAL SECOND FLOOR LIGHTING PLAN - AREA D
SHEET INDEX
SHEET
NUMBER SHEET NAME
INTERIORS
I-101 FIRST FLOOR FURNITURE PLAN
I-102 SECOND FLOOR FURNITURE PLAN
FIRE ALARM
FA001 FIRE ALARM MNS GENERAL NOTES
FA101 FIRST FLOOR FIRE ALARM MNS
FA102 SECOND FLOOR FIRE ALARM MNS
FA401 FIRE ALARM RISER DIAGRAM SECTION
FA601 FIRE ALARM MNS OPERATIONAL MATRIX
FA602 FIRE ALARM MNS CONCEPTUAL RISER
FA603 FIRE ALARM MNS DETAILS
FIRE SUPPRESSION
FX001 FIRE SUPPRESSION GENERAL NOTES
FX101 FIRST FLOOR FIRE SUPPRESSION
FX102 SECOND FLOOR FIRE SUPPRESSION
FX401 ENLARGED FIRE SUPPRESSION PLANS AND SECTIONS
FX501 FIRE SUPPRESSION DETAILS
FX502 FIRE SUPPRESSION DETAILS
PLUMBING
P-001 GENERAL NOTES, LEGENDS , AND ABBREVIATIONS
P-100 FOUNDATION - OVERALL PLAN
P-100A FOUNDATION PLAN - AREA A
P-100B FOUNDATION PLAN - AREA B
P-100C FOUNDATION PLAN - AREA C
P-100D FOUNDATION PLAN - AREA D
P-101 SANITARY AND STORM FIRST FLOOR - OVERALL PLAN
P-101A SANITARY AND STORM FIRST FLOOR - AREA A
P-101B SANITARY AND STORM FIRST FLOOR - AREA D
P-101C SANITARY AND STORM FIRST FLOOR- AREA C
P-101D SANITARY AND STORM FIRST FLOOR - AREA D
P-102 SANITARY AND STORM SECOND FLOOR OVERALL PLAN
P-102A SANITARY AND STORM SECOND FLOOR - AREA A
P-102B SANITARY AND STORM SECOND FLOOR - AREA B
P-102C SANITARY AND STORM SECOND FLOOR - AREA C
P-102D SANITARY AND STORM SECOND FLOOR - AREA D
P-103 ROOF PLAN - OVERALL
P-120 DOMESTIC WATER FIRST FLOOR - OVERALL PLAN
P-121A DOMESTIC WATER FIRST FLOOR - AREA A
P-121B DOMESTIC WATER FIRST FLOOR - AREA B
P-121C DOMESTIC WATER FIRST FLOOR- AREA C
P-121D DOMESTIC WATER FIRST FLOOR - AREA D
P-122 DOMESTIC WATER SECOND FLOOR OVERALL PLAN
P-122C DOMESTIC WATER SECOND FLOOR - AREA C
P-122D DOMESTIC WATER SECOND FLOOR - AREA D
P-130 COMPRESSED AIR AND RADON FIRST FLOOR - OVERALL PLAN
P-131A COMPRESSED AIR AND RADON FIRST FLOOR - AREA A
P-131B COMPRESSED AIR AND RADON FIRST FLOOR - AREA B
P-131C COMPRESSED AIR AND RADON FIRST FLOOR- AREA C
P-131D COMPRESSED AIR AND RADON FIRST FLOOR - AREA D
P-501 DETAILS
P-502 DETAILS
P-503 DETAILS - COMPRESSED AIR SCHEMATIC DIAGRAM
P-504 DETAILS - COMPRESSED AIR
P-601 SCHEDULES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
E-201 ELECTRICAL FIRST FLOOR OVERALL POWER PLAN
E-201A ELECTRICAL FIRST FLOOR POWER PLAN - AREA A
E-201B ELECTRICAL FIRST FLOOR POWER PLAN - AREA B
E-201C ELECTRICAL FIRST FLOOR POWER PLAN - AREA C
E-201D ELECTRICAL FIRST FLOOR POWER PLAN - AREA D
E-202 ELECTRICAL SECOND FLOOR AND LOW ROOF OVERALL POWER PLAN
E-202A ELECTRICAL SECOND FLOOR AND LOW ROOF POWER PLAN - AREA A
E-202B ELECTRICAL SECOND FLOOR AND LOW ROOF POWER PLAN - AREA B
E-202C ELECTRICAL SECOND FLOOR AND LOW ROOF POWER PLAN - AREA C
E-202D ELECTRICAL SECOND FLOOR AND LOW ROOF POWER PLAN - AREA D
E-203 UPPER ELECTRICAL ROOF POWER PLAN
E-301 LIGHTNING PROTECTION & GROUNDING PLAN
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS
E-601 ELECTRICAL ONE-LINE DIAGRAM
E-602 ELECTRICAL EQUIPMENT REQUIREMENTS
E-701 ELECTRICAL PANELBOARD SCHEDULES
E-702 ELECTRICAL PANELBOARD SCHEDULES
E-703 ELECTRICAL PANELBOARD SCHEDULES
E-704 ELECTRICAL LIGHTING FIXTURE SCHEDULE & LIGHT PLATES
E-705 ELECTRICAL LIGHT PLATES
E-706 ELECTRICAL LIGHT PLATES
E-707 ELECTRICAL LIGHT PLATES
E-708 EQUIPMENT SCHEDULE
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS LEGENDS
TS101 TELECOMMUNICATIONS SITE PLAN
TS102 TELECOMMUNICATIONS SITE PLAN DETAILS
T-101 FIRST FLOOR TELECOM & SYSTEMS PLAN
T-102 SECOND FLOOR TELECOM & SYSTEMS PLAN
T-103 FIRST FLOOR TELECOM & SYSTEMS - PATHWAY PLAN
T-104 SECOND FLOOR TELECOM & SYSTEMS- PATHWAY PLAN
T-105 FIRST FLOOR PUBLIC ADDRESS SYSTEM PLAN
T-106 SECOND FLOOR PUBLIC ADDRESS SYSTEM PLAN
T-401 ENLARGED TELECOM PLANS
T-402 ENLARGED TELECOM PLANS
T-403 TELECOM RACK ELEVATIONS
T-404 TELECOM RACK ELEVATIONS
T-501 TELECOMMUNICATIONS DETAILS
T-502 TELECOMMUNICATIONS DETAILS
T-503 TELECOMMUNICATIONS DETAILS
T-504 TELECOMMUNICATIONS DETAILS
T-601 BACKBONE CABLE RISER DIAGRAM
T-602 TELECOMMUNICATIONS RISER DIAGRAMS
T-603 TELECOMMUNICATIONS RISER DIAGRAMS
T-701 CABLE PULL SCHEDULES
T-702 CABLE PULL SCHEDULES
T-703 CABLE PULL SCHEDULES
P-904 COMPRESSED AIR RISER DIAGRAM
MECHANICAL
M-001 MECHANICAL LEGENDS
M-002 MECHANICAL NOTES
MH101 MECHANICAL FIRST FLOOR HVAC PLAN
MH101A MECHANICAL FIRST FLOOR HVAC PLAN - AREA A
MH101B MECHANICAL FIRST FLOOR HVAC PLAN - AREA B
MH101C MECHANICAL FIRST FLOOR HVAC PLAN - AREA C
MH101D MECHANICAL FIRST FLOOR HVAC PLAN - AREA D
MH102 MECHANICAL SECOND FLOOR AND ROOF HVAC PLAN
MH102A MECHANICAL SECOND FLOOR AND ROOF HVAC PLAN - AREA A
MH102B MECHANICAL SECOND FLOOR AND ROOF HVAC PLAN - AREA B
MH102C MECHANICAL SECOND FLOOR AND ROOF HVAC PLAN - AREA C
MH102D MECHANICAL SECOND FLOOR AND ROOF HVAC PLAN - AREA D
MP101 MECHANICAL FIRST FLOOR PIPING PLAN
MP101C MECHANICAL FIRST FLOOR PIPING PLAN - AREA C
MP101D MECHANICAL FIRST FLOOR PIPING PLAN - AREA D
MP102 MECHANICAL SECOND FLOOR PIPING PLAN
MP102D MECHANICAL SECOND FLOOR PIPING PLAN - AREA D
M-103 MECHANICAL FIRST FLOOR HVAC ZONING PLAN
M-104 MECHANICAL SECOND FLOOR HVAC ZONING PLAN
M-301 MECHANICAL SECTIONS
M-302 MECHANICAL SECTIONS
M-401 ENLARGED MECHANICAL PLANS
M-402 ENLARGED MECHANICAL PLANS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-504 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-701 CHILLED WATER PIPING DIAGRAM, CONTROL POINTS, AND SEQUENCE OF
OPERATIONS
M-702 CHILLER CONTROL POINTS LIST
M-703 CHILLED WATER PLANT CONTROL POINTS LIST
M-704 DOAS-1 AIRFLOW AND CONTROL DIAGRAMS
M-705 AHU-1, 2, 3 AIRFLOW AND CONTROL DIAGRAMS
M-706 AHU CONTROL POINTS LIST
M-707 DOAS & VAV CONTROL POINTS LIST
M-708 MISCELLANEOUS CONTROL DIAGRAMS
M-709 MISCELLANEOUS CONTROL POINTS LISTS
M-710 MISCELLANEOUS CONTROL POINTS LISTS
P-90
P-901
2 DOMESTIC RISER DIAGRAM
WASTE & VENT RISER DIAGRAMS
CS50 SITE DETAILS
CG101 GRADING PLAN
CG102 GRADING PLAN
CG201 SECTIONS
CG202 SECTIONS
CG301 EROSION CONTROL PLAN
CG302 EROSION CONTROL PLAN
CG501 EROSION CONTROL DETAILS
CG502 EROSION CONTROL DETAILS
CG503 DRAINAGE DETAILS
CU101 UTILITY PLAN
CU102 UTILITY PLAN
CU201 WATER LINE PROFILES
CU202 STORM SEWER PROFILES
CU203 SANITARY SEWER PROFILES
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CU503 UTILITY DETAILS
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES
S-002 GENERAL STRUCTURAL NOTES
S-003 GENERAL STRUCTURAL NOTES
S-101 FOUNDATION PLAN
S-102 SECOND FLOOR AND LOW ROOF FRAMING PLAN
S-103 ROOF FRAMING PLAN
S-201 CONCRETE WALL ELEVATIONS
S-202 CONCRETE WALL ELEVATIONS
S-203 CONCRETE WALL ELEVATIONS
S-204 CONCRETE WALL ELEVATIONS
S-205 CONCRETE WALL ELEVATIONS
S-401 ENLARGED STAIR PLANS & SECTIONS
S-402 ENLARGED STAIR PLANS & SECTIONS
S-403 ENLARGED ELEVATOR & DETAILS
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
S-503 FOUNDATION DETAILS
S-504 FRAMING DETAILS
S-505 FRAMING DETAILS
S-601 PILE CAP SCHEDULE & DETAILS
S-602 STRUCTURAL FOUNDATION AND SLAB SCHEDULES
S-603 CONCRETE COLUMN SCHEDULE & DETAILS
S-604 CONCRETE GIRDER SCHEDULE & DETAILS
ARCHITECTURE
A-001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
A-101 FIRST FLOOR PLAN
A-102 SECOND FLOOR PLAN
A-111 FIRST FLOOR REFLECTED CEILING PLAN
A-112 SECOND FLOOR REFLECTED CEILING PLAN
A-121 ROOF PLAN
A-131 AIR BARRIER PLANS AND SECTION
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-301 BUILDING SECTIONS
A-302 BUILDING SECTIONS
A-311 WALL SECTIONS
A-312 WALL SECTIONS
A-313 WALL SECTIONS
A-314 WALL SECTIONS
A-401 ENLARGED RESTROOM PLANS AND ELEVATIONS
A-402 ENLARGED FLOOR PLANS AND ELEVATIONS
A-403 ENLARGED STAIR PLANS AND ELEVATIONS
A-404 ENLARGED ELEVATOR PLAN AND SECTIONS
A-405 TOILET ACCESSORIES
A-501 PARTITION TYPES
A-502 TYP. PARTITION AND CEILING DETAILS
A-521 RAILING DETAILS
A-531 SECTION DETAILS
A-532 ROOF DETAILS
A-533 MISC DETAILS
A-601 DOOR SCHEDULE AND TYPES
A-602 WINDOW & STOREFRONT SCHEDULES, TYPES AND DETAILS
A-603 LOUVER SCHEDULE, TYPES AND DETAILS
A-611 DOOR DETAILS
A-612 DOOR DETAILS
A-701 FINISH SCHEDULE AND FINISH LEGEND
A-702 FIRST FLOOR FINISH PLAN
A-703 SECOND FLOOR FINISH PLAN
A-704 INTERIOR DETAILS
A-801 SIGNAGE DETAILS
A-802 SIGNAGE SCHEDULE AND DETAILS
A-803 FIRST FLOOR SIGNAGE PLAN
A-804 SECOND FLOOR SIGNAGE PLAN
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C H
EC
KE
D B
Y:
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
JA
PA
N D
IS
TR
IC
T
U N
IT
AP
O
A P
4-
W
2H
V1 9D
IS
O A
C
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y W
2H
V1 9D
R
. L
EK
BE
R
G
S.
T
IN
IU
S
A.
B
AR
T
R . K
N O
LL
E
D
ES
IG
N
S U
BM
IT
TA
L
JU
LY
N D
V
IC
IN
IT
Y M
AP
S
H
AU
L R
O U
TE
, S
IT
E
LO
C
AT
IO
N
G-003
NOT TO SCALE
VICINITY MAPJ14
OKINAWA
YOMITAN
KIN
GINOZA
NAHA
ITOMAN
PROJECT
LOCATION
NOT TO SCALE
LOCATION MAPA14
COLL
INSON DRIVE
P530
PROJECT
LOCATION
OFF-SITE
PARKING
PROPOSED
CONTRACTOR STAGING/
LAYDOWN AREA
GATE 3
GATE 1
P530
PROJECT
LOCATION
OFF-SITE PARKING
PROJECT LOCATION
DOUGLAS BLVD
COLLINSON DR
DOUGLAS BLVD
NOT TO SCALE
HAUL ROUTED1
PROPOSED
CONTRACTOR STAGING/
LAYDOWN AREA
DOUGLAS BLVD
FAIRCHILD
APPLICABLE CODES AND STANDARDS
INTERNATIONAL BUILDING CODE (IBC) (2024)
NFPA 1, FIRE CODE (2024)
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2022)
NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
(2022)
NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR
APPURTENANCES (2022)
NFPA 33, STANDARD FOR SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE
MATERIALS (2024)
NFPA 69, STANDARD ON EXPLOSION PREVENTION SYSTEM (2024)
NFPA 70, NATIONAL ELECTRIC CODE (2023)
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE (2022)
NFPA 101, LIFE SAFETY CODE (2024)
NFPA 170, STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS (2024)
UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, WITH CHANGE 6 (MAY 2021) UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, WITH CHANGE 2
(JUL 2022)
SUMMARY OF FIRE PROTECTION FEATURES
PROJECT INCLUDES THE FOLLOWING FIRE PROTECTION FEATURES:
WET PIPE SPRINKLER SYSTEM
FIRE ALARM AND DETECTION SYSTEM
FIRE-RESISTANCE RATED CONSTRUCTION
EMERGENCY LIGHTING AND EXIT SIGNS
TWO-WAY COMMUNICATION SYSTEM FOR ELEVATOR LOBBY
PORTABLE FIRE EXTINGUISHERS
APPROVED EQUIVALENCIES
NOT APPLICABLE - NO EQUIVALENCIES HAVE BEEN REQUESTED FOR THIS PROJECT.
CLASSIFICATION OF OCCUPANCY
IBC CHAPTER 3
FACILITY IS CLASSIFIED AS A MIXED-USE OCCUPANCY AND INCLUDES:
ASSEMBLY GROUP A-3 (TRAINING / CONFERENCE)
BUSINESS GROUP B (BREAKROOM, OFFICES, SECURITY)
FACTORY AND INDUSTRIAL F-1 (SHOPS-ARMAMENT, BATTERY, COMPOSITES, ENGINE, NDI,
TIRE & WHEEL, TOOL, WELDING; MAINTENANCE BAY)
HIGH HAZARD H-3 (AVIATION, LIFE SUPPORT, O2 ROOM, PAINT BOOTH)
STORAGE S-1 (TIRE STORAGE, PARTS STORAGE, HAZMAT)
BUILDING AREA SEPARATION
IBC 508
A 1-HOUR FIRE RESISTANCE RATED WALLS ARE PROVIDED TO SEPARATE HIGH HAZARD H-3
OCCUPANCY FROM ADJACENT F-1 OCCUPANCIES FOR A FULLY SPRINKLERED BUILDING PER IBC
TABLE 508.4.
TYPE OF CONSTRUCTION
IBC CHAPTER 6
TYPE II-B (NON-COMBUSTIBLE, NON-RATED)
FIRE-RESISTANCE RATED BUILDING COMPONENTS
IBC TABLE 601
COMPONENT REQUIRED PROVIDED
PRIMARY STRUCTURAL FRAME 0-HOURS 0-HOURS
EXTERIOR BEARING WALLS 0-HOURS 0-HOURS
INTERIOR BEARING WALLS 0-HOURS 0-HOURS
EXTERIOR NONBEARING WALLS AND PARTITIONS 0-HOURS (NOTE 1)
INTERIOR NONBEARING WALLS AND PARTITIONS 0-HOURS (NOTE 2)
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 0-HOURS 0-HOURS
ROOF CONSTRUCTION AND SECONDARY MEMBERS 0-HOURS 0-HOURS
NOTE 1: REFER TO THE "BUILDING SEPARATION AND EXPOSURE PROTECTION" SECTION OF THIS
CODE SUMMARY FOR REQUIRED EXTERIOR WALL RATINGS.
NOTE 2: REFER TO THE "REQUIRED INTERIOR SEPARATION" SECTION OF THIS CODE SUMMARY FOR
ADDITIONAL INTERIOR WALL RATINGS.
HEIGHT LIMITATIONS
IBC SECTION 503 AND 504
TYPE II-B CONSTRUCTION; SPRINKLER PROTECTED
OCCUPANCY TABULAR VALUE PROVIDED
HIGH HAZARD H-3 16.7 M 9.6 M
OCCUPANCY TABULAR VALUE PROVIDED
ASSEMBLY A-3 3 STORIES 2 STORIES
HIGH HAZARD H-3 2 STORIES 1 STORY
TABULAR VALUE = FOR SPRINKLER PROTECTED BUILDING PER IBC.
OVERALL BUILDING COMPLIES WITH THE MOST RESTRICTIVE FOR THE OCCUPANCIES INVOLVED.
AREA LIMITATIONS
IBC SECTION 504 AND 506
TYPE II-B CONSTRUCTION; SPRINKLER PROTECTED
AREA PER FLOOR
FIRST FLOOR
OCCUPANCY TABULAR VALUE FRONTAGE PERMITTED PROVIDED
ASSEMBLY A-3 2,647.6 SM 1,958.7 SM 4,633.3 SM 1,245.0 SM
HIGH HAZARD H-3 1,300.6 SM N/A 1,300.6 SM 108.1 SM
SECOND FLOOR
OCCUPANCY TABULAR VALUE FRONTAGE PERMITTED PROVIDED
ASSEMBLY A-3 2,647.6 SM 1,958.7 SM 4,633.3 SM 847.2 SM
TABULAR VALUE = FOR SPRINKLER PROTECTED BUILDING PER IBC.
FRONTAGE = FRONTAGE INCREASE ALLOWANCE PER IBC.
TOTAL BUILDING AREA
AREA PERMITTED = 1,300.6 SM + (2 X 4,633.3 SM) = 10,567.2 SM
AREA PROVIDED = 1,245.0 SM + 108.1 SM + 847.2 SM = 2,200.3 SM
OVERALL BUILDING COMPLIES WITH THE MOST RESTRICTIVE FOR THE OCCUPANCIES INVOLVED.
BUILDING SEPARATION AND EXPOSURE
PROTECTION
IBC TABLE 601
EXTERIOR BEARING WALL FOR A TYPE II B CONSTRUCTION ARE NOT REQUIRED TO HAVE A FIRE-
RESISTANCE RATING.
IBC TABLE 705.8
THE FIRE SEPARATION FOR ALL SIDES OF THE BUILDINGS IS 10 M OR GREATER. NO ADDITIONAL
FIRE-RESISTANCE RATING IS REQUIRED.
IBC TABLE 705.9
FOR SPRINKLERED BUILDINGS WITH UNPROTECTED OPENINGS WITH A FIRE SEPARATION GREATER
THAN 10 M, THERE IS NO LIMIT TO THE ALLOWABLE AREA FOR OPENINGS.
INCIDENTAL USE AREAS
IBC 509
THERE ARE NO INCIDENTAL USE AREAS AS IDENTIFIED PER IBC TABLE 509.1
MEANS OF EGRESS ILLUMINATION
NFPA 101 7.8
MEANS OF EGRESS ILLUMINATION IS REQUIRED. AUTOMATIC DIMMERS NOT PERMITTED.
REFER TO ELECTRICAL PLANS E-1-01 AND E-102 FOR ADDITIONAL INFORMATION.
EMERGENCY LIGHTING
NFPA 101 7.9
EMERGENCY LIGHTING IS REQUIRED. EMERGENCY LIGHTING WILL PROVIDE AN INITIAL
ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE 10.8 LUX, MEASURED ALONG THE PATH OF
EGRESS AT THE FLOOR LEVEL. AUTOMATIC DIMMERS NOT PERMITTED. REFER TO ELECTRICAL
PLANS E-101 AND E-102 FOR ADDITIONAL INFORMATION.
MEANS OF EGRESS MARKING
NFPA 101 7.10
ILLUMINATED EXIT SIGNAGE IS REQUIRED AT EXITS AND DIRECTIONAL EXIT SIGNAGE REQUIRED
ALONG THE PATH OF EGRESS TRAVEL. REFER TO ELECTRICAL PLANS E-101 AND E-102 FOR
ADDITIONAL INFORMATION.
WATER SUPPLY
IBC, NFPA 24
FIRE HYDRANTS AND THE BUILDING FIRE SUPPRESSION SYSTEMS ARE SUPPLIED BY THE EXISTING
UNDERGROUND WATER DISTRIBUTION SYSTEM. THIS SYSTEM OF UNDERGROUND PIPING HAS
SUFFICIENT CAPACITY TO SUPPLY THE FIRE PROTECTION WATER DEMANDS FOR THE NEW
BUILDING. TO MEET THE PRESSURE REQUIREMENTS, A FIRE PUMP WILL NOT BE INSTALLED AS PART
OF THIS PROJECT.
REFER TO FIRE SUPPRESSION PLANS FX101 FOR ADDITIONAL INFORMATION.
CALCULATED FIRE-FLOW
NFPA 1 TABLE 18.4.5.2.1
FIRE-FLOW IS THE WATER DEMAND (FLOW AND PRESSURE) TO BE PROVIDED AT THE FIRE
HYDRANTS SERVING A PROPERTY FOR FIRE DEPARTMENT USE. NOTE THAT SINCE THE FACILITY IS
SPRINKLER PROTECTED, REDUCTIONS TO THE FIRE-FLOW APPLY.
CONSTRUCTION TYPE TYPE II-B / TYPE II (000)
SPRINKLER SYSTEM YES, PER NFPA 13 WITH QUICK RESPONSE SPRINKLERS
NUMBER OF STORIES 2 STORIES
BUILDING HEIGHT 9.6 M (APPROX.)
FIRE-FLOW CALCULATION AREA 1,889.4 SM (TOTAL BUILDING AREA, ALL FLOORS)
TABULAR FIRE-FLOW 11,355 LPM AT 137.9 KPA
PERMITTED REDUCTIONS YES, REDUCED BY 75% SINCE BUILDING PROTECTED BY
QUICK RESPONSE SPRINKLERS; BUT NOT LESS THAN 3,785
LPM
TABULAR REDUCED FIRE-FLOW 3,785 LPM AT 137.9 KPA
FIRE-FLOW DURATION 2 HOURS
THE FIRE-FLOW IS PROVIDED BY THE CITY WATER SUPPLY SYSTEM SERVING THE SITE. THE FIRE- FLOW IS REQUIRED TO BE PROVIDED BY THE HYDRANTS SERVING THE SITE AT A MINIMUM OF 137.9
KPA.
FIRE HYDRANTS
UFC 3-600-01
FIRE HYDRANTS ARE REQUIRED TO BE PROVIDED SO THAT EACH PART OF THE EXTERIOR
WALL OF THE BUILDING IS WITHIN 106 M OF A FIRE HYDRANT.
THE SERVICE LATERAL FOR A HYDRANT MAY SERVE NOT MORE THAN TWO HYDRANTS AND
SHALL BE A MINIMUM OF 150 MM.
A HYDRANT IS REQUIRED TO BE PROVIDED WITHIN 45 M OF THE FIRE DEPARTMENT
CONNECTION
REFER TO CIVIL PLANS CU101 FOR ADDITIONAL INFORMATION.
FIRE DEPARTMENT CONNECTION (FDC)
UFC 3-600-01 9-3.5.8.4
FIRE DEPARTMENT CONNECTION (FDC) PROVIDED ON THE WALL OF THE SPRINKLER ROOM WITHIN
45 M OF A HYDRANT.
REFER TO FIRE SUPPRESSION PLANS FX101 FOR ADDITIONAL INFORMATION.
POST INDICATING VALVE (PIV)
NFPA 24 6.2.9(6)
A PIV WILL NOT BE PROVIDED ON THE INCOMING FIRE SUPPRESSION WATER SERVICE LINE. AN INDICATING CONTROL VALVE IN A FIRE-RATED ROOM ACCESSIBLE FROM THE EXTERIOR WILL BE PROVIDED IN ITS PLACE. THE INDICATING CONTROL VALVE WILL BE THE OS&Y VALVES AS PART OF
THE BACKFLOW PREVENTER ASSEMBLY WITHIN THE 1-HOUR FIRE-RESISTANCE-RATED FIRE
PROTECTION ROOM.
REFER TO LIFE SAFETY PLAN GI101 AND FIRE SUPPRESSION PLAN FX101 FOR ADDITIONAL
INFORMATION.
AUTOMATIC FIRE SUPPRESSION SYSTEMS
IBC AND NFPA 13
PROVIDE AUTOMATIC WET PIPE SPRINKLER SYSTEM THROUGHOUT THE BUILDING PER NFPA13.
QUICK RESPONSE SPRINKLERS REQUIRED THROUGHOUT THE SYSTEM.
THE FOLLOWING SPRINKLER HAZARD CLASSIFICATIONS ARE EXPECTED IN THE BUILDING:
LIGHT HAZARD – COMMON AREAS, CORRIDORS, OFFICES, ETC.
ORDINARY HAZARD – MECHANICAL ROOMS, UTILITY ROOMS, JANITOR’S CLOSET, ETC.
EXTRA HAZARD – NOT EXPECTED IN THE BUILDING.
REFER TO FIRE SUPPRESSION PLANS FX101 ADN FX102 FOR ADDITIONAL INFORMATION.
BACKFLOW PREVENTION
IBC AND NFPA 13
PROVIDE DOUBLE-CHECK BACKFLOW PREVENTION ASSEMBLY FOR THE FIRE SUPPRESSION
SYSTEM. LOCATE BACKFLOW PREVENTION ASSEMBLY IN ACCORDANCE WITH LOCAL
REQUIREMENTS WITHIN THE FIRE PROTECTION ROOM. PROVIDE A BACKFLOW PREVENTION
ASSEMBLY TEST CONNECTION WITHIN THE FIRE PROTECTION ROOM.
REFER TO FIRE SUPPRESSION PLANS FX101 AND FX401 FOR ADDITIONAL INFORMATION.
STANDPIPE SYSTEM
UFC 3-600-01
THE BUILDING IS TWO STORIES IN HEIGHT, WITH THE HIGHEST LEVEL OF THE BUILDING LOCATED LESS THAN 9,144 MM ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT ACCESS. NO STANDPIPE
SYSTEM IS REQUIRED, AND NOT PROVIDED.
FIRE PUMP
UFC 3-600-01 AND NFPA 20
BASED ON THE PRELIMINARY HYDRAULICS THE WATER SUPPLY IS SUFFICIENT FOR THE BULDING
FIRE SUPPRESSION SYSTEM. NO FIRE PUMP WILL BE REQUIRED.
REFER TO FIRE SUPPRESSION PLANS FX101 FOR ADDITIONAL INFORMATION.
PORTABLE FIRE EXTINGUISHERS
UFC 3-600-01 AND NFPA 101
PROVIDE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH NFPA 10.
REFER TO ARCHITECTURAL PLANS A-101 AND A-102 FOR ADDITIONAL INFORMATION.
SPECIAL SUPPRESSION SYSTEMS
N/A - NO SPECIAL SUPPRESSION SYSTEMS WILL BE INSTALLED.
FIRE DETECTION AND ALARM SYSTEMS
NFPA 101 AND NFPA 72
PROVIDE ADDRESSABLE, CLASS B, FIRE DETECTION AND FIRE ALARM SYSTEM. PROVIDE PUBLIC
SPACES WITH STROBES PER NFPA 72 AND ADA STANDARDS. THE FIRE ALARM SYSTEM SHALL
INCLUDE MANUAL PULL STATIONS, SMOKE DETECTORS, HEAT DETECTORS, DUCT SMOKE
DETECTORS, HORN/STROBE OR SPEAKER/STROBE NOTIFICATION APPLIANCES, TRANSMITTER,
ELECTRICAL SUPERVISION OF SPRINKLER SYSTEM ALARM AND SUPERVISORY DEVICES, AND
ELECTRICAL SUPERVISION OF FIRE PUMP CONTROLLER. PROVIDE NOTIFICATION APPLIANCES WITH
CLEAR STROBES MARKED "ALERT". VISIBLE NOTIFICATION WILL BE INSTALLED IN NORMALLY
OCCUPIED SPACES LARGER THAN 84 SM, AND ANY SPACE WHERE NORMALLY PRESENT AMBIENT
NOISE WOULD REQUIRE HEARING PROTECTION.
REFER TO FIRE ALARM PLANS FA101 AND FA102 FOR ADDITIONAL INFORMATION.
MASS NOTIFICATION SYSTEM
UFC 3-600-01
PROVIDE MASS NOTIFICATION SYSTEM (MNS) COMBINED WITH THE FIRE ALARM SYSTEM. MNS
SYSTEM SHALL BE PROVIDED WITH A MICROPHONE AND HAS THE ABILITY TO PERFORM PUBLIC
ADDRESS (PA) PAGING FUNCTIONS. MASS NOTIFICATION SYSTEM MESSAGES AND FIRE ALARM
MESSAGES SHALL TAKE PRIORITY OVER PUBLIC ADDRESS ANNOUNCEMENTS.
PROVIDE THE FOLLOWING FEATURES FOR THE COMBINED FIRE ALARM AND MASS NOTIFICATION:
AUDIBILITY AND INTELLIGIBILITY THROUGHOUT BUILDING.
SCROLLING LED TEXT SIGNS AT EACH EXIT AND SUBSTANTIAL MEANS OF EGRESS.
LOCAL OPERATING CONSOLE (LOC) WITHIN THE MAIN PANEL.
ADDITIONAL LOCAL OPERATING CONSOLE (LOC) AT PRIMARY AND SECONDARY ENTRANCES.
WEATHERPROOF SPEAKERS WILL BE PROVIDED ON THE EXTERIOR OF THE BUILDING.
BACK-UP AMPLIFIER PROVIDED FOR THE COMBINATION FIRE ALARM/MASS NOTIFICATION
SYSTEM.
REFER TO FIRE ALARM PLANS FA101 AND FA102 FOR ADDITIONAL INFORMATION.
CARBON MONOXIDE (CO) SYSTEM
UFC 3-600-01 AND NFPA 72
CO DETECTION IS REQUIRED IN EACH MECHANICAL OR UTILITY SPACE CONTAINING FUEL-FIRED APPLIANCES OR EQUIPMENT. CO DETECTION IS ALSO REQUIRED OUTSIDE OF THE MECHANICAL OR UTILITY SPACE WHERE THE ADJACENT AREA IS SERVED BY A SEPARATE AIR HANDING SYSTEM. CO DETECTION WILL NOT BE PROVIDED AS PART OF THIS PROJECT. NO FUEL FIRED APPLIANCES OR
EQUIPMENT WILL BE INSTALLED. NO GAS LINES UTILITIES WILL BE INSTALLED.
CONNECTION TO REPORTING SYSTEM
UFC 3-600-01 9-18.3 AND NFPA 72
THE FAMNS WILL TRANSMIT TO A REPORTING SYSTEM. THESE SYSTEMS WILL TRANSMIT A SIGNAL FROM THE BUILDING VIA A MONACO BT-XM IN-BUILDING COMMUNICATOR TO STATION #2. FROM STATION #2, THE SIGNAL WILL BE TRANSMITTED TO THE INSTALLATION FIRE STATION. THE FIRE
REPORTING PORTION OF THE SYSTEM SHALL BE COMPATIBLE WITH THE EXISTING SIGNAL
COMMUNICATIONS SYSTEM. NARROWBAND SIGCOM ONE-WAY TRANSMITTER SHALL INCLUDE
ANTENNA, ANTENNA SUPPORT, REQUIRED CABLES AND CONNECTORS, SURGE SUPPRESSORS,
APPURTENANCES, CONDUIT AND WIRE BETWEEN THE TRANSMITTER AND ANTENNA, AND CONDUIT
AND WIRE BETWEEN THE TRANSMITTER AND BUILDING 120VAC POWER SUPPLY. IF AN INDIVIDUAL
CUTOFF SWITCH IS NECESSARY, PROVIDE DEDICATED RED COLORED CUTOFF SWITCH BETWEEN
THE 120VAC POWER SOURCE AND TRANSMITTER.
REFER TO FIRE ALARM PLANS FA602 AND FA603 FOR ADDITIONAL INFORMATION.
PUBLIC ADDRESS SYSTEM
A PUBLIC ADDRESS SYSTEM WILL BE INSTALLED AS PART OF THIS PROJECT. THE PUBLIC ADDRESS SYSTEM WILL NOT BE A PART OF THE BUILDING MASS NOTIFICATION SYSTEM (MNS). THE MNS WILL
OVERRIDE THE PUBLIC ADDRESS SYSTEM WHEN AN MNS MESSAGE IS ACTIVATED. PROVIDE
SYSTEM PROGRAMMING SUCH THAT AUTOMATIC FIRE ALARM/MNS MESSAGES HAVE HIGHEST
PRIORITY AND PAGING FUNCTIONS HAVE LOWEST PRIORITY. STROBES SHALL NOT ILLUMINATE
DURING PUBLIC ADDRESS ANNOUNCEMENTS.
REFER TO FIRE ALARM PLANS FA601 FOR ADDITIONAL INFORMATION.
EMERGENCY AIR DISTRIBUTION SHUTOFF SYSTEM
UFC 4-010-01, SECTION B-4.3
PROVIDE EMERGENCY AIR DISTRIBUTION SHUTOFF SYSTEM IN ACCORDANCE WITH UFC 4-010-01, SECTION B-4.3. PROVIDE DISTINCTLY COLORED AND DISTINCTLY IDENTIFIABLE STANDALONE
SWITCHES LOCATED ACCORDING TO UFC 4-010-01. SWITCHES ARE REQUIRED TO BE MUSHROOM
SWITCHES WITH COVERS OR PUSH BUTTONS WITH COVERS, DEDICATED TO SHUTTING DOWN AIR
MOVEMENT SYSTEMS, AIR MOVEMENT COMPONENTS, AIR CONDITIONING AND HEATING SYSTEMS,
AND DAMPERS AS REQUIRED BY UFC 4-010-01.
THIS SYSTEM IS DETAILED IN THE MECHANICAL DESIGN AND IS LISTED HEREIN FOR REFERENCE
ONLY.
ELEVATOR EMERGENCY OPERATION
IBC AND ASME A17.1
PROVIDE ELEVATOR EMERGENCY OPERATIONS (PHASE I AND PHASE II):
PHASE I ELEVATOR RECALL, INITIATED BY SMOKE DETECTION.
PHASE II FIRE FIGHTER OPERATION OF THE ELEVATOR AFTER THE ELEVATOR HAS BEEN
RECALLED.
PRIMARY RECALL LOCATION = FIRST FLOOR
ALTERNATE RECALL LOCATION = SECOND FLOOR
ELEVATOR PROTECTION
UFC 3-600-01, 4-16
ELEVATOR TYPE = ELECTRIC TRACTION
PROVIDE 1-HOUR FIRE RESISTANCE RATED CONSTRUCTION FOR ELEVATOR HOISTWAYS AND THE
ELEVATOR MACHINE ROOMS. ELEVATOR DOORS RATED AT 60 MINUTES ARE ACCEPTABLE TO HOST
NATION REQUIREMENTS. SMOKE DETECTORS IN EACH ELEVATOR LOBBY AND IN THE ELEVATOR
MACHINE ROOMS. THESE SMOKE DETECTORS SHALL INITIATE PHASE I ELEVATOR RECALL. THE
PRIMARY RECALL LOCATION IS REQUIRED TO BE THE FIRST FLOOR, AND THE ALTERNATE RECALL
LOCATION IS REQUIRED BE THE SECOND FLOOR.
SPRINKLER(S) WITH LISTED GUARDS ARE REQUIRED WITHIN THE ELEVATOR MACHINE ROOMS.
ADDITIONALLY, A SUPERVISED SHUT-OFF VALVE, CHECK VALVE, WATERFLOW SWITCH (WITH NO TIME DELAY CAPABILITY), AND TEST VALVE SHALL BE PROVIDED IN THE SPRINKLER PIPING SERVING THE MACHINE ROOMS. THESE ITEMS ARE REQUIRED TO BE LOCATED OUTSIDE AND ADJACENT TO
THE AREA THEY SERVE. FLOW SWITCH ACTUATION OF THE WATERFLOW SWITCH SHALL REMOVE
POWER TO THE ELEVATOR(S) SERVED BY THAT MACHINE ROOM BY SHUNT TRIP BREAKER.
AN INSPECTOR'S TEST CONNECTION IS REQUIRED FOR EACH WATERFLOW SWITCH ASSOCIATED
WITH THE ELEVATOR MACHINE ROOMS. THE TEST CONNECTION IS REQUIRED TO BE LOCATED
OUTSIDE THE MACHINE ROOM WITH THE TEST CONNECTION PIPING ROUTED TO A FLOOR DRAIN
LOCATION THAT CAN ACCEPT FULL FLOW OR WHERE WATER MAY BE DISCHARGED WITHOUT
PROPERTY DAMAGE. DISCHARGE TO A FLOOR DRAIN MAY BE PERMITTED ONLY IF THE DRAIN IS SIZED TO ACCOMMODATE FULL FLOW (MINIMUM OF 40 GPM). DISCHARGE TO SERVICE SINKS OR A
SIMILAR PLUMBING FIXTURES IS NOT PERMITTED.
REFER TO FIRE SUPPRESSION FX101, FX102 AND FIRE ALARM PLANS FA101, FA102 FOR ADDITIONAL
INFORMATION.
ELEVATOR LOBBY TWO-WAY COMMUNICATION
UFC 3-600-01 10.7.6, NFPA 101 7.2.12
PROVIDE TWO-WAY COMMUNICATION SYSTEM FOR THE ELEVATOR LANDING ON THE SECOND
FLOOR FOR COMMUNICATION BETWEEN THE ELEVATOR LANDING AND A CENTRAL CONTROL POINT
LOCATED NEAR THE MAIN ENTRANCE ON THE FIRST FLOOR.
DIRECTIONS FOR THE USE OF THE SYSTEM, INSTRUCTIONS FOR SUMMONING ASSISTANCE VIA THE TWO-WAY COMMUNICATION SYSTEM, AND WRITTEN IDENTIFICATION OF THE LOCATION SHALL BE
POSTED ADJACENT TO THE TWO-WAY COMMUNICATION SYSTEM.
THE TWO-WAY COMMUNICATION SYSTEM SHALL INCLUDE BOTH AUDIBLE AND VISIBLE SIGNALS.
REFER TO ELEVATOR SPECIFICATION 14 21 23 FOR ADDITIONAL INFORMATION.
FIRE DEPARTMENT VEHICLE ACCESS
UFC 3-600-01 9-1.1
FIRE DEPARTMENT VEHICLE ACCESS IS REQUIRED WITHIN 10 M OF THE BUILDING AND SHALL
SUPPORT THE SIZE AND WEIGHT OF THE LOCAL FIRE DEPARTMENT VEHICLES. MINIMUM CLEAR
WIDTH IS 6 M.
THE BUILDING WILL BE LOCATED BEHIND A SECURED FENCE, ACCESSED FROM TWO VEHICLE
ACCESS GATES. ACCESS CONTROL OF THE VEHICLE GATES WILL BE PROVIDED TO RESPONDING
FIRE DEPARTMENT. THE BUILDING WILL BE PROVIDED WITH VEHICLE DRIVE ACCESS AROUND THE
ENTIRE PERIMETER.
REFER TO CIVIL PLANS CS101 FOR ADDITIONAL INFORMATION.
RESPONDING PERSONNEL ACCESS
NFPA 1
PRIMARY ENTRANCE IS THE MAIN DOORS TO THE OFFICE AREA ON THE FIRST FLOOR AT ENTRY 100.
SECONDARY ENTRANCES ARE PROVIDED AT ALL OTHER SIDES OF THE BUILDING. THE BUILDING
WILL BE PROVIDED WITH A 24 HOUR SECURITY PRESENCE THAT CAN PROVIDE ACCESS TO
RESPONDING PERSONNEL.
TWO-WAY RADIO ENHANCEMENT SYSTEM
NFPA 1221
TWO-WAY RADIO COMMUNICATION SHALL BE ASSESSED DURING CONSTRUCTION. WITH SIGNAL
DETERIORATION, PROVIDE TWO-WAY RADIO COMMUNICATION ENHANCEMENT SYSTEM TO
INCREASE RADIO SIGNAL STRENGTH FOR FIRE DEPARTMENT COMMUNICATION. THE TWO-WAY
RADIO COMMUNICATION ENHANCEMENT SYSTEM IS REQUIRED TO COMPLY WITH NFPA 72.
ROOF ACCESS
IBC 1011.12
ROOF ACCESS WILL BE PROVIDED FROM TWO ROOF HATCHES, ABOVE FIRST FLOOR MECHANICAL
ROOMS. THESE ROOF HATCHES WILL PROVIDE ACCESS TO THE LOW ROOF ABOVE THE FIRST
FLOOR. THE ROOF ABOVE THE SECOND FLOOR WILL BE ACCESSED FROM AN EXTERIOR FIXED
LADDER, ACCESSED FROM THE LOW ROOF.
REFER TO ARCHITECTURAL PLANS A-121 FOR ADDITIONAL INFORMATION.
HAZARDOUS MATERIALS
HAZARDOUS MATERIALS WILL BE STORED WITHIN THE BUILDING IN A DEDICATED ROOM AND
LOCKERS. STORAGE AND USE OF HAZARDOUS MATERIALS WILL COMPLY WITH GOVERNMENT AND
LOCAL REGULATIONS.
SMOKE MANAGEMENT
N/A - SMOKE MANAGEMENT IS NOT REQUIRED FOR THIS PROJECT.
REQUIRED INTERIOR SEPARATIONS
COMPONENT REQUIRED RATING PROVIDED RATING
EXIT ENCLOSURE 1-HOUR 1-HOUR
ELEVATOR HOISTWAY 1-HOUR 1-HOUR
ELEVATOR MACHINE ROOM 1-HOUR 1-HOUR
SHAFTS 1-HOUR 1-HOUR
FIRE PROTECTION ROOM 1-HOUR 1-HOUR
ELECTRICAL ROOM (EQUIP >1200 AMPS) 1-HOUR 1-HOUR
ELECTRICAL ROOM (EQUIP <1200 AMPS) SMOKE PARTITION (NR) SMOKE PARTITION (NR)
MECHANICAL ROOMS SMOKE PARTITION (NR) SMOKE PARTITION (NR)
CORRIDOR WALLS (NR) (NR)
AVIATION LIFE SUPPORT / 02 ROOM 2-HOUR 2-HOUR
PAINT SPACES 2-HOUR 2-HOUR
BATTERY STORAGE 1-HOUR 1-HOUR
NOTE: (NR) = NON-RATED
VERTICAL OPENINGS
IBC
EXCEPT FOR THE SHAFTS, EXIT STAIRS, AND ELEVATORS, THERE ARE NO ADDITIONAL VERTICAL OPENINGS IN THE BUILDING. PLEASE REFER TO THE "REQUIRED INTERIOR SEPARATIONS" SECTION
OF
THIS CODE SUMMARY FOR THE PROTECTION REQUIREMENTS OF THE SHAFTS AND ELEVATORS.
(VERTICAL OPENINGS INCLUDE ATRIUMS, CONVENIENCE OPENINGS, TWO-STORY OPENINGS, AND
OPEN STAIRS, ETC.)
INTERIOR FINISH REQUIREMENTS
NFPA 101 CHAPTER 10
INTERIOR FINISH SHALL COMPLY WITH THE CRITERIA FOR MOST RESTRICTIVE OCCUPANCY, WITH
PERMITTED REDUCTION FOR COMPLETE AUTOMATIC SPRINKLER SYSTEM:
COMPONENT INTERIOR FINISH FLOOR FINISH
EXITS A OR B I OR II
EXIT ACCESS CORRIDORS A, B OR C I OR II
OTHER SPACES A, B, OR C NOT APPLICABLE
FOR INTERIOR FINISH:
CLASSIFICATION FLAME SPREAD INDEX SMOKE DEVELOPMENT INDEX
CLASS A 0 - 25 0 - 450
CLASS B 26 - 75 0 - 450
CLASS C 76 - 200 0 - 450
FOR FLOOR FINISH:
CLASSIFICATION CRITICAL RADIANT FLUX
CLASS I >0.45 W/SQ.CM
CLASS II 0.22 - 0.45 W/SQ.CM
OCCUPANT LOAD
NFPA 101
USE OCCUPANT LOAD FACTOR (OLF)
ASSEMBLY (LESS CONCENTRATED) 1.4 SM PER PERSON (NET)
BUSINESS (LESS CONCENTRATED) 14 SM PER PERSON (GROSS)
INDUSTRIAL (GENERAL AND HIGH HAZARD) 9.3 SM PER PERSON (GROSS)
STORAGE (GENERAL) 46.5 SM PER PERSON (GROSS)
REFER TO LIFE SAFETY PLANS FOR TABULAR CALCULATIONS OF OCCUPANT LOAD AND
IDENTIFICATION OF OCCUPANT LOAD FACTOR USED FOR EACH SPACE.
NUMBER OF EXITS
NFPA 101 7.4
MINIMUM NUMBER OF EXITS ARE REQUIRED FOR EACH STORY AS FOLLOWS:
FOR AN OCCUPANT LOAD OF LESS THAN 500 PERSONS - NOT LESS THAN 2 EXITS
STORY OCCUPANT LOAD EXITS REQUIRED EXITS PROVIDED
FIRST FLOOR LESS THAN 500 2 12
SECOND FLOOR LESS THAN 500 2 2
REQUIRED SEPARATION OF EXITS
NFPA 101 7.5
IF TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED, THEY SHALL BE ARRANGED AND
PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-THIRD OF THE MAXIMUM OVERALL
DIAGONAL OF THE SPACE, ROOM, STORY OR BUILDING SERVED.
SPACE OVERALL DIAGONAL MINIMUM SEPARATION PROVIDED
MAINTENANCE BAY 27.31 M 9.1 M 21.6 M
TRAINING / CONF 15.82 M 5.27 M 11.43 M
EXIT CAPACITY AND EXIT WIDTH
NFPA 101 7.2, 7.3
COMPONENT EGRESS CAPACITY FACTOR HIGH HAZARD
STAIRWAYS 7.3 MM PER PERSON 18 MM PERSON
LEVEL COMPONENTS AND RAMPS 5 MM PER PERSON 10 MM PERSON
REQUIRED EXIT WIDTH FOR THE MEANS OF EGRESS:
MINIMUM CLEAR WIDTH OF DOORS IS 810 MM
MINIMUM WIDTH OF STAIRS IS 1120 MM
MINIMUM WIDTH OF RAMPS IS 1120 MM
MINIMUM WIDTH CORRIDORS IS 1120 MM
EGRESS ARRANGEMENT
NFPA 101
USE TRAVEL DIST. COMMON PATH DEAD END CORRIDOR
ASSEMBLY (<50 PERSONS) 76 M (MAX) 6.1 M (MAX) 6.1 M (MAX)
ASSEMBLY (>50 PERSONS) 76 M (MAX) 23 M (MAX) 6.1 M (MAX)
BUSINESS 91 M (MAX) 30 M (MAX) 15 M (MAX)
INDUSTRIAL - GENERAL 76 M (MAX) 30 M (MAX) 15 M (MAX)
INDUSTRIAL - HIGH HAZARD 23 M (MAX) N/A N/A
STORAGE - ORDINARY HAZARD 122 M (MAX) 30 M (MAX) 30 M (MAX)
FIRE PROTECTION RELATED ITEMS THAT SHALL
BE U.S. PRODUCTS
THE FOLLOWING FIRE PROTECTION RELATED ITEMS SHALL BE U.S. TESTING METHODS (E.G.,
ASTM/UL/FM) WITH TESTING LABELS AS REQUIRED. THESE ITEMS SHALL NOT BE SUBSTITUTED WITH JAPANESE TESTING METHODS (E.G., JIS, JASS, ETC.). FOR EXAMPLE, A JAPANESE FIRE DOOR WITH UL DOCUMENTATION THAT THE DOOR HAS PASSED ANSI/UL WOULD BE ACCEPTABLE IN US FUNDED
PROJECTS.
FIRE SUPPRESSION SYSTEM INCLUDING VALVES, ALARM VALVES, SPRINKLER HEADS (PIPES
AND FITTINGS OF JAPANESE MANUFACTURER MAY MEET THE FUNCTIONAL REQUIREMENTS)
FIRE PUMPS INCLUDING MOTORS, CONTROLLERS, DRIVES, AND VALVES
FIRE ALARM AND MASS NOTIFICATION SYSTEMS INCLUDING PANELS, INITIATING DEVICES,
NOTIFICATION APPLIANCES, SMOKE ALARMS (CONDUCTORS AND CONDUITS OF JAPANESE
MANUFACTURERS MAY MEET THE FUNCTIONAL REQUIREMENTS)
ENGINEERING TECHNICIAN REQUIREMENTS FOR DEVELOPMENT OF FIRE SUPPRESSION
SYSTEMS AND ALARM SHOP DRAWINGS, CALCULATIONS, AND MATERIAL SUBMITTALS
FIRE DOORS AND FRAME ASSEMBLIES
FIRE DAMPERS AND SMOKE DAMPERS
INTERIOR FINISHES WITH FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS
INSULATION WITH FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS
PLENUM RATED CABLES
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
IS
O
A
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
W
2H V-
-D
-0
W
2H V1
9D
J.
ZI
MM
ER
MA
N
A.
M
ILL
ER
R.
K
NO
LL
E
M.
M
EA
DE
GI001
C O
D E
SU
M
M
AR
Y
SH
EE
T
C O
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
W
2H V1
9D
JA
PA
N D
IS
TR
IC
T
U ni t 3
AP
O A
P
4-
JU
LY
W
2H V1
9D
_ G
I00
D
ES
IG
N
S U
BM
IT
TA
L
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
LIFE SAFETY LEGEND
1-HOUR FIRE BARRIER
45-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
FIRE DAMPERS REQUIRED FOR
TRANSFER DUCTED SYSTEMS
PENETRATING 1-HOUR WALLS
1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
1-HOUR EXIT ENCLOSURE
60-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
2-HOUR FIRE BARRIER
90-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
FIRE DAMPERS REQUIRED FOR DUCTED
SYSTEMS
2-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
XXX EXIT IDENTIFIER
TRAVEL DISTANCE (TD)
COMMON PATH OF TRAVEL (CPT)
DEAD END (DE) CORRIDOR
EXIT SIGN
(SEE ELECTRICAL PLANS)
(FOR REFERENCE ONLY)
PORTABLE FIRE
EXTINGUISHER
SURFACE MOUNTED CABINET
TYPE = DRY CHEMICAL
RATING = 2A:B:C (MINIMUM)
FEC-SURF
2-HOUR EXIT ENCLOSURE
90-MIN RATED OPENING PROTECTIVES
(DOORS AND WINDOWS)
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
2-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
SMOKE PARTITION
DOORS TO RESIST THE PASSAGE OF
SMOKE; SMOKE SEALS NOT REQUIRED
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
SMOKE DAMPERS REQUIRED FOR AIR
TRANSFER OPENINGS
PORTABLE FIRE EXTINGUISHER
WALL BRACKET
TYPE = DRY CHEMICAL
RATING = 2A:B:C (MINIMUM)BRKT
EXIT
IDENTIFIER
DOOR
CLEAR WIDTH
(MM)
DOOR CAPACITY
FACTOR
(MM/PERSON)
DOOR
CAPACITY
(PERSONS)
STAIR
WIDTH
(IN)
STAIR
CAP.FACTOR
(MM/PERSON)
STAIR
CAPACITY
(PERSONS)
LIMITING
CAPACITY
(PERSONS)
ACTUAL
USE
(PERSONS)
EXIT SUMMARY - FIRST FLOOR
TOTAL 129
692 850 5 170 N/A 170 7N/A N/A
903 1700 5 340 N/A 340N/A N/A
904 1700 5 340 N/A 340N/A N/A
847 850 5 170 N/A 170N/A N/A 0
929 1700 5 340 N/A 340N/A N/A 8
865 1700 5 340 N/A 340N/A N/A 1
933 1700 5 340 N/A 340N/A N/A 1
897 850 5 170 N/A 170N/A N/A 21
641 850 5 170 N/A 170 26N/A N/A
640 850 5 170 N/A 170 26N/A N/A
19 850 5 170 N/A 170 0N/A N/A
18 850 5 170 N/A 170 14N/A N/A
860 1700 5 340 N/A 340N/A N/A 15
880 850 5 170 N/A 170N/A N/A 8
THE FOLLOWING FIRE PROTECTION RELATED
ITEMS SHALL MEET U.S. TESTING METHODS (E.G.,
ASTM/UL/FM) WITH TESTING LABELS AS
REQUIRED. THESE ITEMS SHALL NOT BE
SUBSTITUTED WITH JAPANESE TESTING
METHODS (E.G., JIS, JASS, ETC.). FOR EXAMPLE,
A JAPANESE FIRE DOOR WITH UL
DOCUMENTATION THAT THE DOOR HAS PASSED
ANSI/UL WOULD BE ACCEPTABLE IN US FUNDED
PROJECTS.
FIRE SUPPRESSION SYSTEM INCLUDING
VALVES, ALARM VALVES, SPRINKLER
HEADS (PIPES AND FITTINGS OF JAPANESE
MANUFACTURER MAY MEET THE
FUNCTIONAL REQUIREMENTS)
FIRE PUMPS INCLUDING MOTORS,
CONTROLLERS, DRIVES, AND VALVES
FIRE ALARM AND MASS NOTIFICATION
SYSTEMS INCLUDING PANELS, INITIATING
DEVICES, NOTIFICATION APPLIANCES,
SMOKE ALARMS (CONDUCTORS AND
CONDUITS OF JAPANESE
MANUFACTURERS MAY MEET THE
FUNCTIONAL REQUIREMENTS)
ENGINEERING TECHNICIAN
REQUIREMENTS FOR DEVELOPMENT OF
FIRE SUPPRESSION SYSTEMS AND ALARM
SHOP DRAWINGS, CALCULATIONS, AND
MATERIAL SUBMITTALS
FIRE DOORS AND FRAME ASSEMBLIES
FIRE DAMPERS AND SMOKE DAMPERS
INTERIOR FINISHES WITH FLAME SPREAD
AND SMOKE DEVELOPMENT RATINGS
INSULATION WITH FLAME SPREAD AND
SMOKE DEVELOPMENT RATINGS
PLENUM RATED CABLES
FIRE PROTECTION PRODUCT NOTES
VESTIBULE
MATERIAL /
TOOL SHOP
WELDING
SHOP
MMCO/MMC
OFFICE
102A
NDI SHOP -
INSPECTION
CALIBRATION
TIRE
STORAGE
115A
NDI SHOP -
TEST
116A
HAZMAT
TIRE &
WHEEL
SHOP
CLEAN RM 2
108B
STORAGE
108A
AWSE
(ARMAMENT
WEAPONS
SUPPORT
EQUIPMENT)
WOMEN
BREAK
PAINT
ROOM
119D
MECHANICAL
120A
AVIATION
LIFE
SUPPORT
DRY /CURE
119B
LEAD ACID
BATT
118B
ELEVATOR
NIPR COMM
ELECTRICAL
SECURITY
MEN
NI-CAD BATT
118A
BATTERY
SHOP
MAINTENANCE
BAY
MAINTENANCE/
PRODUCTION
CONTROL
ELEVATOR
EQUIPMENT
STAIR
STAIR
CORRIDOR
100A
COMPOSITE
SHOP
CLEAN RM 1
108C
PARTS
STORAGE
ENGINE
SHOP - RFI
STORAGE
CORRIDOR
PAINT SHOP
- PREP &
PAINTING
STORAGE
119A
EXIT
120C
EXIT
116D
EXIT
109F
EXIT
109B
EXIT
EXIT
EXIT
EXIT
EXIT
100C
EXIT
117B
EXIT
120A
O2 ROOM
120B
23.1
TD3
10.0
CPT2
4.3
DE
22.7
TD2
15.2
CPT3
17.1
CPT1
25.6
TD1
A B C D E F G H
20.0
TD4
FIRE
PROTECTION
MECHANICAL
JAN
100B
MECHANICAL
113A
EXIT
113C
EXIT
113A
BRKT
BRKT BRKT
FEC-SR
BRKT
EXIT
123B
VESTIBULE
119C
FEC-SURF
FEC-SURF
FEC-SURF
FEC-SURF
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
IS
O
A
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
W
2H V-
-D
-0
W
2H V1
9D
J.
ZI
MM
ER
MA
N
A.
M
ILL
ER
R.
K
NO
LL
E
M.
M
EA
DE
GI101
FI
R
ST
F
LO
O
R L
IF
E
SA
FE
TY
P
LA
N
C O
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
W
2H V1
9D
JA
PA
N D
IS
TR
IC
T
U ni t 3
AP
O A
P
4-
JU
LY
W
2H V1
9D
_ G
I10
D
ES
IG
N
S U
BM
IT
TA
L
EGRESS ARRANGEMENT - FIRST FLOOR
MARK LENGTH (M) FROM ROOM TO ROOM
CPT1 17.1 PAINT ROOM 119D CORRIDOR 117
CPT2 10.0 CLEAN RM 1 108C CORRIDOR 100A
CPT3 15.2 MMCO/MMC OFFICE 102A CORRIDOR 100A
DE 4.3 CORRIDOR 117 CORRIDOR 117
TD1 25.6 NI-CAD BATT 118A CORRIDOR 117
TD2 22.7 WELDING SHOP 111 MAINTENANCE BAY 109
TD3 23.1 NIPR COMM 107 VESTIBULE 100
TD4 20.0 TIRE STORAGE 115A MAINTENANCE BAY 109
OCCUPANT LOAD - FIRST FLOOR
ROOM
NO. ROOM NAME OCCUPANCY USE AREA OLF
OCCUPANT
LOAD
100 VESTIBULE BUSINESS 6 m² 14 1
100A CORRIDOR BUSINESS 47 m² 14 4 100B JAN BUILDING EQUIPMENT ROOM 3 m² 27.9 1 101 SECURITY BUSINESS 8 m² 14 1 102 MAINTENANCE/ PRODUCTION CONTROL BUSINESS 26 m² 14 2
102A MMCO/MMC OFFICE BUSINESS 14 m² 14 1 103 MEN BUSINESS 11 m² 14 1 104 WOMEN BUSINESS 6 m² 14 1 105 BREAK BUSINESS 6 m² 14 1 106 ELECTRICAL BUILDING EQUIPMENT ROOM 8 m² 27.9 1 107 NIPR COMM STORAGE (GENERAL) 10 m² 46.5 1 108 COMPOSITE SHOP INDUSTRIAL (GENERAL) 21 m² 9.3 3
108A STORAGE STORAGE (GENERAL) 8 m² 46.5 1 108B CLEAN RM 2 INDUSTRIAL (GENERAL) 15 m² 9.3 2 108C CLEAN RM 1 INDUSTRIAL (GENERAL) 15 m² 9.3 2 109 MAINTENANCE BAY INDUSTRIAL (GENERAL) 229 m² 9.3 25 110 MATERIAL / TOOL SHOP INDUSTRIAL (GENERAL) 52 m² 9.3 6 111 WELDING SHOP INDUSTRIAL (GENERAL) 45 m² 9.3 5 112 HAZMAT INDUSTRIAL (GENERAL) 9 m² 9.3 1 113 PARTS STORAGE INDUSTRIAL (GENERAL) 123 m² 9.3 14
113A MECHANICAL BUILDING EQUIPMENT ROOM 10 m² 27.9 1
114 AWSE (ARMAMENT WEAPONS SUPPORT
EQUIPMENT)
INDUSTRIAL (GENERAL) 64 m² 9.3 7
115 TIRE & WHEEL SHOP INDUSTRIAL (GENERAL) 57 m² 9.3 7 115A TIRE STORAGE STORAGE (GENERAL) 9 m² 46.5 1 116 NDI SHOP - INSPECTION CALIBRATION INDUSTRIAL (GENERAL) 37 m² 9.3 5
116A NDI SHOP - TEST INDUSTRIAL (GENERAL) 11 m² 9.3 2 117 CORRIDOR BUSINESS 48 m² 14 4 118 BATTERY SHOP INDUSTRIAL (GENERAL) 14 m² 9.3 2
118A NI-CAD BATT STORAGE (GENERAL) 8 m² 46.5 1 118B LEAD ACID BATT STORAGE (GENERAL) 9 m² 46.5 1 119 PAINT SHOP - PREP & PAINTING INDUSTRIAL (HIGH HAZARD) 34 m² 9.3 4
119A STORAGE STORAGE (GENERAL) 4 m² 46.5 1 119B DRY /CURE INDUSTRIAL (HIGH HAZARD) 5 m² 9.3 1 119C VESTIBULE NO OCCUPANCY 5 m² 0 119D PAINT ROOM INDUSTRIAL (HIGH HAZARD) 22 m² 9.3 3 120 AVIATION LIFE SUPPORT INDUSTRIAL (HIGH HAZARD) 61 m² 9.3 7
120A MECHANICAL BUILDING EQUIPMENT ROOM 8 m² 27.9 1 120B O2 ROOM INDUSTRIAL (HIGH HAZARD) 4 m² 9.3 1 121 STAIR NO OCCUPANCY 22 m² 0 122 ENGINE SHOP - RFI STORAGE INDUSTRIAL (GENERAL) 36 m² 9.3 4 123 STAIR NO OCCUPANCY 22 m² 0 124 ELEVATOR EQUIPMENT NO OCCUPANCY 9 m² 0 125 ELEVATOR NO OCCUPANCY 8 m² 0 126 FIRE PROTECTION NO OCCUPANCY 12 m² 0 127 MECHANICAL BUILDING EQUIPMENT ROOM 37 m² 27.9 2
Total 129
1 : 100
FIRST FLOOR LIFE SAFETY PLAN
A1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NORTH
0 2000
SCALE: 1: 100
EXIT
IDENTIFIER
DOOR
CLEAR WIDTH
(MM)
DOOR CAPACITY
FACTOR
(MM/PERSON)
DOOR
CAPACITY
(PERSONS)
STAIR
WIDTH
(MM)
STAIR
CAP.FACTOR
(MM/PERSON)
STAIR
CAPACITY
(PERSONS)
LIMITING
CAPACITY
(PERSONS)
ACTUAL
USE
(PERSONS)
EXIT SUMMARY - SECOND FLOOR
TOTAL
7.3
7.3
LIFE SAFETY LEGEND
1-HOUR FIRE BARRIER
45-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
FIRE DAMPERS REQUIRED FOR
TRANSFER DUCTED SYSTEMS
PENETRATING 1-HOUR WALLS
1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
1-HOUR EXIT ENCLOSURE
60-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
1-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
2-HOUR FIRE BARRIER
90-MIN RATED DOORS
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
FIRE DAMPERS REQUIRED FOR DUCTED
SYSTEMS
2-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
XXX EXIT IDENTIFIER
TRAVEL DISTANCE (TD)
COMMON PATH OF TRAVEL (CPT)
DEAD END (DE) CORRIDOR
EXIT SIGN
(SEE ELECTRICAL PLANS)
(FOR REFERENCE ONLY)
PORTABLE FIRE
EXTINGUISHER
SURFACE MOUNTED CABINET
TYPE = DRY CHEMICAL
RATING = 2A:B:C (MINIMUM)
FEC-SURF
2-HOUR EXIT ENCLOSURE
90-MIN RATED OPENING PROTECTIVES
(DOORS AND WINDOWS)
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
2-HOUR RATED FIRESTOPPING FOR
PENETRATIONS PER UL LISTED METHOD
SMOKE PARTITION
DOORS TO RESIST THE PASSAGE OF
SMOKE; SMOKE SEALS NOT REQUIRED
DOORS REQUIRED TO BE SELF-CLOSING
AND POSITIVE LATCHING
SMOKE DAMPERS REQUIRED FOR AIR
TRANSFER OPENINGS
PORTABLE FIRE EXTINGUISHER
WALL BRACKET
TYPE = DRY CHEMICAL
RATING = 2A:B:C (MINIMUM)BRKT
THE FOLLOWING FIRE PROTECTION RELATED
ITEMS SHALL MEET U.S. TESTING METHODS (E.G.,
ASTM/UL/FM) WITH TESTING LABELS AS
REQUIRED. THESE ITEMS SHALL NOT BE
SUBSTITUTED WITH JAPANESE TESTING
METHODS (E.G., JIS, JASS, ETC.). FOR EXAMPLE,
A JAPANESE FIRE DOOR WITH UL
DOCUMENTATION THAT THE DOOR HAS PASSED
ANSI/UL WOULD BE ACCEPTABLE IN US FUNDED
PROJECTS.
FIRE SUPPRESSION SYSTEM INCLUDING
VALVES, ALARM VALVES, SPRINKLER
HEADS (PIPES AND FITTINGS OF JAPANESE
MANUFACTURER MAY MEET THE
FUNCTIONAL REQUIREMENTS)
FIRE PUMPS INCLUDING MOTORS,
CONTROLLERS, DRIVES, AND VALVES
FIRE ALARM AND MASS NOTIFICATION
SYSTEMS INCLUDING PANELS, INITIATING
DEVICES, NOTIFICATION APPLIANCES,
SMOKE ALARMS (CONDUCTORS AND
CONDUITS OF JAPANESE
MANUFACTURERS MAY MEET THE
FUNCTIONAL REQUIREMENTS)
ENGINEERING TECHNICIAN
REQUIREMENTS FOR DEVELOPMENT OF
FIRE SUPPRESSION SYSTEMS AND ALARM
SHOP DRAWINGS, CALCULATIONS, AND
MATERIAL SUBMITTALS
FIRE DOORS AND FRAME ASSEMBLIES
FIRE DAMPERS AND SMOKE DAMPERS
INTERIOR FINISHES WITH FLAME SPREAD
AND SMOKE DEVELOPMENT RATINGS
INSULATION WITH FLAME SPREAD AND
SMOKE DEVELOPMENT RATINGS
PLENUM RATED CABLES
FIRE PROTECTION PRODUCT NOTES
ELEVATOR
NIPR COMM
CO
210B
XO
210A
TRAINING /
CONFERENCE
QUALITY
ASSURANCE
OFFICE
MEN
LOCKER
CORRIDOR
WOMEN
LOCKER
BREAK
MECH.
STAIR
STAIR
JAN.
SIPR CAFE
EXIT
EXIT
11.1
CPT2
32.2
TD1
A B C D E F G H
ADMIN
DEPARTMENT
SEL
210C
OPEN TO BELOW
FIRST FLOOR LOW ROOF
FIRST FLOOR LOW ROOF
MOTHERS
ROOM
3.4
DE
BRKT
BRKT
FIRST FLOOR LOW ROOF
29.4
CPT1
FEC-SURF
23.8
TD2
ELECTRICAL
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
C H
EC
KE
D B
Y:
US Army Corps of Engineers ®
IS
O
A
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
W
2H V-
-D
-0
W
2H V1
9D
J.
ZI
MM
ER
MA
N
A.
M
ILL
ER
R.
K
NO
LL
E
M.
M
EA
DE
GI102
SE
C
O N
D F
LO
O
R L
IF
E
SA
FE
TY
P
LA
N
C O
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y
W
2H V1
9D
JA
PA
N D
IS
TR
IC
T
U ni t 3
AP
O A
P
4-
JU
LY
W
2H V1
9D
_ G
I10
D
ES
IG
N
S U
BM
IT
TA
L
EGRESS ARRANGEMENT - SECOND FLOOR
MARK LENGTH (M) FROM ROOM TO ROOM
CPT1 29.4 MECH. 203
CPT2 11.1 SEL 210C CORRIDOR 200
DE 3.4 CORRIDOR 200 CORRIDOR 200
TD1 32.2 MEN LOCKER 209 STAIR 215
TD2 23.8 TRAINING / CONFERENCE 207 STAIR 213
OCCUPANT LOAD - SECOND FLOOR
ROOM
NO. ROOM NAME OCCUPANCY USE AREA OLF
OCCUPANT
LOAD
200 CORRIDOR BUSINESS 66 m² 14 5 201 NIPR COMM IT EQUIPMENT 9 m² 28 1 202 ELECTRICAL BUILDING EQUIPMENT ROOM 12 m² 27.9 1 203 MECH. BUILDING EQUIPMENT ROOM 12 m² 27.9 1 204 SIPR CAFE BUSINESS (COLLAB <41.8 SM) 9 m² 2.8 4 205 QUALITY ASSURANCE OFFICE BUSINESS 26 m² 14 2 206 BREAK BUSINESS 14 m² 14 1 207 TRAINING / CONFERENCE ASSEMBLY (LESS CONC.) 105 m² 1.4 76 208 WOMEN LOCKER BUSINESS 19 m² 14 2 209 MEN LOCKER BUSINESS 42 m² 14 3 210 ADMIN DEPARTMENT BUSINESS 27 m² 14 2
210A XO BUSINESS 9 m² 14 1 210B CO BUSINESS 13 m² 14 1 210C SEL BUSINESS 9 m² 14 1 211 MOTHERS ROOM BUSINESS 9 m² 14 1 212 JAN. BUILDING EQUIPMENT ROOM 3 m² 27.9 1 213 STAIR NO OCCUPANCY 22 m² 0 214 ELEVATOR NO OCCUPANCY 8 m² 0 215 STAIR NO OCCUPANCY 27 m² 0
Total 103
1 : 100
SECOND FLOOR LIFE SAFETY PLAN
A1
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
NORTH
0 2000
SCALE: 1: 100
D
CI
C I
D
D
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
ASPHALT
D
CB
D
D
C I
C I
D
C I
C I
C I
C
I D CB
C I
CB
CB
CB
CB
D
PROTECTIVE
PILLAR, TYP
CB
PROTECTIVE
PILLAR, TYP
CB
CB
CB
PROTECTIVE
PILLAR, TYP
CB
CB
CB
D
WATER FAUCET
UNKNOWN
ELECTRICAL BOX
D
D
CB
CB
T
CB
CB
C I
D
E PARKING AREA 1
LIGHT CONTROL
PANEL
CI
C O
LL
IN
SO
N
D R
IV
E
B-1
B-2
B-5
B-4
B-3
X
X
X
X
X
X
X
X
X
X X
X
X
X
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C H
EC
KE
D B
Y:
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
JA
PA
N D
IS
TR
IC
T
U N
IT
AP
O
A P
4-
W
2H
V1 9D
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y W
2H
V1 9D
EK
BE
R
G
S.
T
IN
IU
S
A.
B
AR
T
R . K
N O
LL
E
D
ES
IG
N
S U
BM
IT
TA
L
JU
LY
LEGEND
0 6.25 12.5m
PLAN
NORTH
BO
IN
G
L O
C
AT
IO
N
M
AP
B-101SCALE 1:250
BORING LOCATION
SCALE = 1:250
BORING LOCATION MAPA1
BENCHMARK
R6-406
ELEV: 54.047
BENCHMARK
R6-407
ELEV: 55.686
BENCHMARK
R6-201
ELEV:52.068
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
T
T
T
ASPHALT
ASPHALT
ASPHALT
EXTERIOR UNIT
MATERIAL STORAGE AREA
TREES
B-A
B-B
TANK
EX BLDG
PA
LM
BE
AC
H
ST
RE
ET
ASPHALT
PARKING
ASPHALT
PARKING
BO
IN
G
L O
C
AT
IO
N
M
AP
B-102
3 F
OU
NT
AI
NS
P
AR
KW
AY
SU
IT
E
FA
IR
VI
EW
H
EI
GH
TS
, I
L
8-
8.6
.70
W
OO
LP
ER
T, In c.
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
C H
EC
KE
D B
Y:
A
D R
AW
IN
G C
O D
E:
B
C
D
E
F
G
1 2 3 4 5 6
SHEET ID
Japan District
7 8 9 10
H
J
K
L
M
N
P
Q
R
11 12 13 14 15 16 17 18 19 20 21
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
JA
PA
N D
IS
TR
IC
T
U N
IT
AP
O
A P
4-
W
2H
V1 9D
M
FL
EA
C
T O
KI
N
AW
A
JA
K
AD
EN
A
AF
B, O
KI
N
AW
A, J
AP
AN
P5
A
IR
C
R
AF
T
IN
TE
R
M
ED
IA
TE
M
AI
N
TE
N
AN
C E
FA
C
IL
IT
Y W
2H
V1 9D
EK
BE
R
G
S.
T
IN
IU
S
A.
B
AR
T
R . K
N O
LL
E
D
ES
IG
N
S U
BM
IT
TA
L
JU
LY
LEGEND
0 6.25 12.5m
PLAN
NORTH
SCALE 1:250
BORING LOCATION
SCALE = 1:250
BORING LOCATION MAPA1
| 01 - GENERAL |
| G-001 - COVER SHEET |
| G-002 - SHEET INDEX |
| G-003 - AND VICINITY MAPS HAUL ROUTE, SITE LOCATION, |
| 02 - LIFE SAFETY |
| GI001 - CODE SUMMARY SHEET |
| GI101 - FIRST FLOOR LIFE SAFETY PLAN |
| GI102 - SECOND FLOOR LIFE SAFETY PLAN |
| 03 - GEOTECHNICAL |
| B-101 - BORING LOCATION MAP |
| B-102 - BORING LOCATION MAP |
| B-103 - BORING LOGS |
| 04 - SURVEY MAPPING |
| V-100 - OVERALL EXISTING CONDITIONS |
| V-101 - EXISTING CONDITIONS |
| V-102 - EXISTING CONDITIONS |
| 05 - CIVIL |
| C-001 - LEGEND |
| CD101 - DEMOLITION PLAN |
| CD102 - DEMOLITION PLAN |
| CS101 - SITE PLAN |
| CS102 - SITE PLAN |
| CS103 - GEOMETRY PLAN |
| CS104 - GEOMETRIC PLAN |
| CS105 - LEGEND |
| CJ101 - JOINTING PLAN |
| CS501 - SITE DETAILS |
| CS502 - SITE DETAILS |
| CS503 - SITE DETAILS |
| CS504 - SITE DETAILS |
| CG101 - GRADING PLAN |
| CG102 - GRADING PLAN |
| CG201 - SECTIONS |
| CG202 - SECTIONS |
| CG301 - EROSION CONTROL PLAN |
| CG302 - EROSION CONTROL PLAN |
| CG501 - EROSION CONTROL DETAILS |
| CG502 - EROSION CONTROL DETAILS |
| CG503 - DRAINAGE DETAILS |
| CU101 - UTILITY PLAN |
| CU102 - UTILITY PLAN |
File details come from the government source that posted it. Updated .