REF. DRAWINGS SEVEN BAYS AS-BUILT DRAWING

OF

SHEET

REVISED

DATE:

TECH. REVIEW:

DESIGNED: DRAWING NO.

NATE KROHN

DECEMBER 2005

DRAFT

PROPOSED:

AT:

COUNTY: STATE:

APPLICATION BY:

LOCATE PARK FACILITIES/UTILITIES

SEVEN BAYS MARINA

LINCOLN WASHINGTON

U.S. DEPT. OF INTERIOR

NATIONAL PARK SERVICE

LAKE ROOSEVELT N.R.A.NORTH

50050

SCALE OF FEET

70024-B

606-70024 (1989)

Ex. Fire Hydrant (In-operable)

Sprinkler System Shut-Off Valve

2" Shut-Off Valve

To Dock System

2" Meter

To Campground

2" Shut-Off Valve

Main Water Shut-Off

Gravel Parking Lot

Gravel

CTEC Storage

Gravel Parking/Storage

4" Backflow Preventer (In-Operable)

(2) Propane Tanks

Temp Plug & Block

Temp Plug

Temp Plug & Block

Boat Launch

Emergency Propane

Underground Fuel Tanks

Fuel Tank Vent Line

Gravel Road

ABS Piranha 5 Duplex Lift Station

Inv. 1286.90

Top 1294.40

48" SS MH Top 1294.40

10 LF 8" PVC @ 1%

Grease Trap

4" San. Sewer

3" PVC Sanitary Sewer Force Main 3" PVC Sanitary Sewer Force Main

8" PVC (Class 125)

Dosing Tank W/ Dosing Counter

2500 Gallon Septic Tank (Typical)

6" PVC (Class 160)

1 1/4" Sch. 40 Laterals W/

13/16" Orifice at 6 O'clock

At 3' Spacing (Typical)

Gravel Road

To Campground

To Campground

Go ve rnm en t B ou nd ary

L ine

Vault Toilet

Dumpster Pad

Dock G

Dock F

Dock E

Dock A

Dock B

Houseboat Dock

Dock J

Dock K

Dock I

Gas Dock Building

Gas Pump

Gas Shut-Off To Docks

Water Shut-Off To Docks

Turf/Day Use Area

Power Fuel Reels (2) Power Electrical Reel

Electrical Panel/Emergency Shut-Off To Docks

Fee Station

Transformer

Electrical Meter &

& Block

Frost Free

Spiket (Typ.)KEY NOTES

Location Of Water and Sewer Lines From The Concrete Bulkhead To The

Refer To Drawing 606-70021 For Building Details

Refer To Drawing 606-70024 For Utility Details

Docks I, J and K Should Be Disconnected At Lake Elevation 1260'

If Lake Elevation Is Projected To Go Below 1250', Docks I, J and K

Dock Utilities (Electrical, Water, Fuel,Sewer) For Docks I, J and K Are Not

10,000 lb Anchor (Replaced Summer, 2005 Including Cable)

10,000 lb Anchors

Wench Cable

All Dock Anchors Are 3,500 Pounds Unless Labeled Otherwise

All Underground Electric Lines Under Roadways And Parking Lots Are Encased

In Sch. 40 Grey Conduit - Contact: Inland Power (Davenport) (800) 747-7151

(2) 2" Fuel Lines

Covered Moorage Dock System High Water Mark (Elevation 1290')

Conc. Stairs Down (Typ.)

Conc. Bulkhead

En d Of

Pa vem ent

Fuel Tank Vent

Government Boundary Line

4" Shut-Off Valve

2" Fuel Line

Lake Roosevelt High Water Mark (Elevation 1290')

Government Boundary Line

LEGEND

Refrigeration

As Of 12/2005 This Anchor Is On

The North Side Of The Boat

Launch (Needs To Be Re-Designed)

Come-Along Tied To Conc. Stairs (Typical Docks A&B)

Catch Basin

Sanitary Sewer Line

Water Line

Three Phase Underground Electric Line

(Lid Is 12-16" Below Grade)

Identified On This Map

Should Be Moved Out Of The Marina

Valves/Manhole Are Estimated (Field Verify)

BuildingTransformer Electrical Meter &

Vault (Typ.)

3 Phase Transformer

Power Pole

Storage Bldg.

M# 70108588

M# 85179362

3,500 Dock Anchor Unless Labeled Otherwise

Electrical Transformer

M Electrical Meter

Overhead Power Pole

Overhead Power

To Campground

3 Phase Electrical Transformer Vault

Gas Pump

Boat Launch Parking Lot

N 59000

N 59500

N 59500

Log Parking Barriers (Typ,)

6" Gate Valve

Pole Building

Campground -Route Unknown

6" Water Line To RRE

Propane Shutoff Underground Power To

Shut-Off

Propane Tank (Installed Spring 2006)M

B F P

H B

HB

HB

G

G

M

M

HLam Typewritten Text

THIS IS INFORMATIONAL ONLY, CONTRACTOR SHALL FIELD VERIFY CONDITIONS.

HLam Line

HLam Line

HLam Line

HLam Line

HLam Line

HLam Line

HLam Line

HLam Typewritten Text

LOWER MOUNTING HEIGHT OF

ELECTRICAL SERVICE TO I DOCK

HLam Typewritten Text

HOSE REEL TO BE

REMOVED

HLam Typewritten Text

GANGWAY

HLam Typewritten Text

FUEL HOUSE AND WAYNE

DISPENSER TO BE

REMOVED

HLam Typewritten Text

OVERHEAD LIGHT

HLam Typewritten Text

GAS BOY DISPENSER

TO BE REMOVED.

INSTALL NEW TWIN

DISPENSER

HLam Typewritten Text

STRAIN RELIEF

CONNECTION

LOCATION

HLam Line

HLam Typewritten Text

PROPOSED LOCATION OF

TRANSITION SUMP, TO BE

VERIFIED.

FLEX HOSE FROM THIS POINT

TO HOSE REEL LOCATION.

FLEX PIPE FROM THIS POINT

TO FUEL HOUSE

HLam Line

HLam Line

HLam Typewritten Text

APPROXIMATE

STAGING AREA

TO BE DELINEATED

BY THE COR

HLam Line

HLam Oval

HLam Typewritten Text

GAS PUMP

TO BE

REMOVED

HLam Line

Swelch Typewritten Text Attachment 3: Drawing and Photos

Swelch Typewritten Text Repair electrical and fuel systems, Seven Bays marina, Lake Roosevelt NRA

SEVEN BAYS MARINA

Inspect and repair overhead light on I dock

Replace light fixtures and support posts on J dock

Swelch Typewritten Text

Swelch Typewritten Text Attachment 3: Drawing and Photos

Swelch

Remove, dispose dispenser

Relocate this dispenser to location of the dispenser above

Swelch Typewritten Text

Swelch

Attachment 3: Drawing and Photos

Lower mounting height to 24 inches above deck , secure support

Swelch

Attachment 3: Drawing and Photos

Attachment A 7 Bays NPS AS BUILT DRAFT
Layout1

Photos for SOW

File details come from the government source that posted it. Updated .