This document is a set of specifications for a federal contract opportunity to renovate and expand the Urology Clinic at the Harry S. Truman Memorial Veterans' Hospital in Columbia, Missouri. The project involves the installation of various signage, cubicle curtain tracks, wall and door protection, toilet and bath accessories, fire extinguisher cabinets, countertops, and seismic restraint requirements for non-structural components. Key details include the project number (589A4-23-050), a description of the required products and services, and applicable industry standards and building codes. The solicitation number is 36C25524R0088 and the contracting agency is the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 15.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Harry S Truman Memorial Veterans Hospital Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
SIGNAGE & GRAPHICS ELEVS.
Fourth Floor South Elevators
Elevation at 4th Floor South Elevator Scale: 1/4” = 1’-0”
Elevation at 4th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”
1/4”=1’ 4th floor elevators - south A elevation
1/4”=1’ 4th floor elevators - south B elevation - adjacent wall
2’-0”
3’-0”
3’-4”3’-0”
CENTEREQ EQ
4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
Title
1/4”=1’ 4th floor elevators - south A elevation
1/4”=1’ 4th floor elevators - south B elevation - adjacent wall
2’-0”
3’-0”
3’-4”3’-0”
CENTEREQ EQ
4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
Title
3.12
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
SIGNAGE & GRAPHICS ELEVS.
Fifth Floor South Elevators
Elevation at 5th Floor South Elevator Scale: 1/4” = 1’-0”
Elevation at 5th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”
1/4”=1’ 5th floor elevators - south A elevation
1/4”=1’ 5th �oor elevators - south B elevation - adjacent wall
2’-0”
3’-0”
CENTEREQ EQ
4”
3’-0” 3’-4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
Title
1/4”=1’ 5th floor elevators - south A elevation
1/4”=1’ 5th �oor elevators - south B elevation - adjacent wall
2’-0”
3’-0”
CENTEREQ EQ
4”
3’-0” 3’-4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
3.13
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
SIGNAGE & GRAPHICS ELEVS.
Sixth Floor South Elevators
Elevation at 6th Floor South Elevator Scale: 1/4” = 1’-0”
Elevation at 6th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”
1/4”=1’ 6th �oor elevators - south A elevation
2’-0”
3’-0”
1/4”=1’ 6th floor elevators - south B elevation - adjacent wall
CENTEREQ EQ
4”
3’-0” 3’-4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
Title
1/4”=1’ 6th �oor elevators - south A elevation
2’-0”
3’-0”
1/4”=1’ 6th floor elevators - south B elevation - adjacent wall
CENTEREQ EQ
4”
3’-0” 3’-4”
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title
Title Title Title Title Title Title Title Title Title Title
B
Title Title Title Title Title Title Title Title Title Title
Title
Title
Title Title
Title
3.14
SE
CT
IO
N
M
ES
SA
GE
S
CH
ED
UL
E
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.1
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
B E ^ Veterans' Hospital A E2 ^ University Hospital B
B B02 J < J3 University Hospital
Restroom
B03 H Audiology Clinic / Speech Pathology B04 Cardiology / Thoracic Clinic B14 Cysto Urology Lab
Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine B B04 H listed above
B B05 F < F1 Meals on Wheels Nuclear Medicine South Elevators
University Hospital Tunnel
B01
B
INTERIOR MESSAGE SCHEDULE BASEMENT FLOOR
1-1 Price separately per floor
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.2
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
B B06 F < F1 University Hospital Tunnel
Meals on Wheels Nuclear Medicine South Elevators
< J2 Restroom
Meals on Wheels Nuclear Medicine South Elevators
B B08 J < J2 University Hospital Tunnel
North Elevators Restrooms
B B09 J > J3 Meals on Wheels Nuclear Medicine South Elevators
B B10 E ^ South Elevators A E2 ^ University Hospital B
B B11 J > J3 North Elevators Nuclear Medicine Restrooms University Hospital
B B12 J < J2 South Elevators Exit to Smoking Shelter
Engineering Control Center Freight Elevators Sterile Processing Warehouse Meals on Wheels
B B13 F < F1 Patient Effects Smoking Shelter
Meals on Wheels Nuclear Medicine University Hospital Tunnel
B B14 H listed above
B B07 J
INTERIOR MESSAGE SCHEDULE BASEMENT FLOOR
1-2
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.3
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 101 E Red Clinic page 1.8 E1
1 102 E Red Clinic E1
1 103 E White Clinic page 1.8 E1
1 104 E Blue Clinic page 1.8 E1
1 105 J ^ J2 Information
Red Clinic
1 106 H Audiology Clinic / Speech Pathology 3 108 Cardiology / Thoracic Clinic 145 Cysto Urology Lab
Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
1-3
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.4
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 107 F > F1 Blue Clinic Red Clinic White Clinic
Emergency Department Information
1 108 H listed above
1 109 F < F1 Blue Clinic Red Clinic White Clinic
Admissions / Eligibilty Agent Cashier Emergency Department Information Pharmacy Pre-Registration Travel
1 110 E ^ Red Clinic E1
1 111 J > J3 Check-In Red Clinic White Clinic Blue Clinic
1 112 J > J3 Release of Information Pharmacist Counseling
1 113 E ^ Travel Agent Cashier page 1.8 E1
1 114 E ^ Pharmacy page 1.8 E1
1 115 J > J1 Blue Clinic Red Clinic White Clinic
Audiology Clinic / Speech Pathology Details Office Emergency Department Imaging
OEF / OIF / OND
Patient Representative Same Day Surgery
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
1-4
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.5
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 116 E ^ Emergency Department A E1
Red / White / Blue Clinics > ^ Information B < Red / White / Blue Clinics
1 117 E Admissions / Eligibility > A E2 < Admissions / Eligibility B
1 118 G Admissions / Eligibilty 2 121 Agent Cashier
Audiology Clinic / Speech Pathology Blue Clinic Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Details Office Emergency Department Imaging Outpatient Lab
OEF / OIF / OND
Patient Representative Patriot Cafe / Store Pharmacy Police Pre-Registration Release of Information Red Clinic Same Day Surgery Silver Clinic Travel Vending / ATM White Clinic
Auditorium Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Sleep Disorders Center Specialty Clinic Urology
Chapel
EEO
Hospital Director Truman Community Living Center Vending Voluntary Service
1-5
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.6
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 118 4 Medicine Inpatient Unit
121 Step Down Unit continued Dialysis
Compensation & Pension Clinic Fee Basis
MCCR
Service Representatives Vending
6 Intensive Care Unit 6 Surgery / Medicine
Nuclear Medicine Meals on Wheels
1 119 E < Pharmacist Counseling A E2 Pharmacist Counseling > B
1 120 E Information page 1.8 E1
1 121 G listed above
1 122 E Restrooms page 1.8 E2
1 123 J ^ J1 Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Details Office Dental Clinic Imaging Outpatient Lab Patriot Cafe / Store Same Day Surgery Silver Clinic
1 124 E < Admissions / Eligibility J3
1 125 E Pre-Registration E2
1-6
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.7
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 126 J ^ J1
Admissions / Eligibility Agent Cashier Details Office Emergency Department Information
OEF / OIF / OND
Pharmacy Patient Representative Pre-Registration Red / White / Blue Clinics Silver Clinic Travel
1 127 J < J1 Audiology Clininc / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Details Office Imaging Patriot Cafe / Store Same Day Surgery Silver Clinic
Emergency Department Pre-Registration Red / White / Blue Clinics
1 128 E Imaging page 1.8 E1
1 129 J ^ J1 Audiology Clininc / Speech Pathology Cardiology Lab Cysto Urology Lab Same Day Surgery South Elevators
Details Office Patriot Cafe / Store Patient Representative Silver Clinic Vending / ATM
1-7
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.8
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 130 E < Details Office A E2 Details Office > B
1 131 J > J1 Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery
Dental Clinic Outpatient Lab Patriot Cafe / Store Silver Clinic Vending / ATM
1 132 E < Vending / ATM A E2 Vending / ATM > B
1 133 J ^ J1 Dental Clinic Cardiology / Thoracic Clinic Cysto Urology Lab Outpatient Lab Patroit Cafe / Store
Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery Vending / ATM
Silver Clinic
1 134 J ^ J1 Information Main Lobby
Silver Clinic
Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery Vending / ATM
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
1-8
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.9
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 135 E Main Lobby E2
1 136 E Silver Clinic E1
1 137 E < Audiology Clinic / Speech Pathology A E1 Audiology Clinic / Speech Pathology > B
1 138 E < Patriot Cafe A E1 Patriot Cafe > B
1 139 E Patriot Store E1
1 140 E ^ South Elevators A E2 ^ Main Lobby B
1 141 E < Surgery A E1 Surgery > B
1 142 J > J3 Audiology Clinic / Speech Pathology Details Office Imaging
1 143 E Same Day Surgery E1
1 144 J < J3 Dental Clinic Outpatient Lab Patriot Cafe / Store South Elevators
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
1-9
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.10
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 145 H listed above
1 146 F ^ F2 Cardiology / Thoracic Clinic Cysto Urology Lab Police
Admissions / Eligibility Agent Cashier Dental Clinic Information Patriot Café / Store Pharmacy Pre-Registration Outpatient Lab Red / White / Blue Clinics Silver Clinic Travel
Audiology Clinic / Speech Pathology Cardio Lab Details Office Emergency Department Imaging
OEF / OIF / OND
Patient Representative Same Day Surgery Vending / ATM
1 147 E ^ Main Lobby E2
1 148 J ^ J1 Dental Clinic
Outpatient Lab
Cardiology / Thoracic Clinic Cysto Urology Lab Police Same Day Surgery
INTERIOR MESSAGE SCHEDULE 1ST FLOOR
1-10
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.11
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 149 J < J3
Patriot Cafe / Store Information / Main Lobby Silver Clinic
Dental Clinic
Outpatient Lab
1 150 E < Outpatient Lab A E1 Outpatient Lab > B
1 151 E Dental Clinic E1
1 152 E Police E2
1 153 J < J2 Patriot Cafe / Store Information / Main Lobby Silver Clinic South Elevators
Cardiology / Thoracic Clinic
1 154 E Cardiology / Thoracic Clinic > E1
1 155 J < J3 Patriot Café / Store Information / Main Lobby Police South Elevators
1 156 E < Cardiology / Thoacic Clinic A E1 Cardiology / Thoracic Clinic > B
1 157 E < Urology Procedures Clinic A E1 Urology Procedures Clinic > B
1-11
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.12
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
1 158 E Cardiology / Thoracic Clinic E1
1 159 J < J3 Information / Main Lobby Patriot Café / Store Silver Clinic
1 160 J > J3 Outpatient Lab Dental Clinic South Elevators
INTERIOR MESSAGE SCHEDULE FIRST FLOOR
1-12
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.13
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
2 201 E Endoscopy Clinic / E1 Pulmonary Function Testing
2 202 E Specialty Clinic E1
2 203 E E2 not used
2 204 F < F1 Bronze Clinic Eye Clinic modify height
> if needed Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic
VIST
2 205 H Audiology Clinic / Speech Pathology 3 207 Cardiology / Thoracic Clinic 231 Cysto Urology Lab
Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
INTERIOR MESSAGE SCHEDULE SECOND FLOOR
1-13
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.14
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
2 206 F < F1 Endpscopy Clinic / Pulmonary Function Testing Specialty Clinic
VIST
Bronze Clinic Eye Clinic ENT Clinic Urology (Coumadin) Warfarin Clinic
2 207 H listed above
2 208 E Restroom page 1.8 E1
2 209 E Eye Clinic E1
2 210 J ^ J1 Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic
VIST
Eye Clinic
Bronze Clinic Restroom
2 211 I < Endoscopy Clinic / Pulmonary Function Testing Eye Clinic Specialty Clinic
VIST
Bronze Clinic Restroom Urology
2 212 J ^ J2 Restroom
Bronze Clinic
INTERIOR MESSAGE SCHEDULE SECOND FLOOR
1-14
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.15
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
2 213 E Bronze Clinic E1
2 214 J ^ J2 Bronze Clinic Eye Clinic Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic
VIST
2 215 E Optical Shop E2
2 216 J < J2 Green Team Clinics
2 217 J < J3 Green Team Clinics
Physical Medicine / Rehabilitation
2 218 E Green Clinic E1
2 219 E Green Clinic > E1
2 220 J < J2 Bronze Clinic Eye Clinic Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic
VIST
Auditorium Physical Medicine / Rehabilitation
INTERIOR MESSAGE SCHEDULE SECOND FLOOR
1-15
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.16
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
2 221 J ^ J2 Auditorium EEG Lab Prosthetics South Elevators
Physical Medicine / Rehabilitation Occupational Therapy / Physical Therapy
2 222 E Physical Medicine / E1 Rehabilitation Occupational Therapy / Physical Therapy
2 223 E Physical Medicine / E1 Rehabilitation
2 224 J < J3 Brace & Amputee Clinic SCI & MS Clinic
2 225 J < J2 Occupational Therapy / Physical Therapy
Cardiac Rehabilitation Sleep Disorders Center
2 226 E Green Team Clinics E1
2 227 E Green Clinic E1
2 228 E Green Team Clinics E1
2 229 J > J2 Green Team Clinics
INTERIOR MESSAGE SCHEDULE SECOND FLOOR
1-16
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.17
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
2 230 E Green Clinic > E2
2 231 H listed above
2 232 F ^ F2 Auditorium
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Physical Medicine / Rehabilitation Specialty Clinic
Green Clinic
2 233 J ^ J1 Auditorium
Physical Medicine / Rehabilitation Occupational Therapy / Physical Therapy
Green Clinic South Elevators
2 234 E Physical Medicine / E1 Rehabilitation
Occupational Therapy / Physical Therapy
2 235 E < Cardiac Rehabilitation A E1 Cardiac Rehabilitation > B
2 236 E < Sleep Disorder Clinic A E1 Sleep Disorder Clinic > B
2 237 E Auditorium E1
2 238 J ^ J2 Physical Medicine / Rehabilitation Occupational Theraphy / Physical Therapy
Prosthetics Cardiac Rehabilitation Sleep Disorders Center
INTERIOR MESSAGE SCHEDULE SECOND FLOOR
1-17
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.18
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
3 301 J > J3
3 302 J > J2 Vending Truman Community Living Center
3 303 E Vending E2
3 304 J ^ J2 Vending
South Elevators
3 305 E ? E1
3 306 J < J2 Chapel Craft Room Home Based Primary Care Medical Library Medical Media
Vending
3 307 J ^ J3 Public Telephone Vending
INTERIOR MESSAGE SCHEDULE THIRD FLOOR
1-18
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.19
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
3 308 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
3 309 F ^ F2 Chapel Human Resources Medical Library Nursing Education Voluntary Service
Truman Community Living Center
EEO
Home Based Primary Care Hospital Director Medical Media Vending
INTERIOR MESSAGE SCHEDULE THIRD FLOOR
1-19
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.20
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
3 310 J ^ J2 Hospital Director Medical Media Vending
Chapel Human Resources Medical Library Nursing Education Voluntary Service
3 311 E Human Resources E1
3 312 J > J3 Chapel Home Based Primary Care Medical Library Medical Media Nursing Education
3 313 J > J3 Home Based Primary Care Medical Library Medical Media Nursing Education
3 314 J > J2 Home Based Primary Care
Chapel Medical Library
INTERIOR MESSAGE SCHEDULE THIRD FLOOR
1-20
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.21
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
4 401 E Step Down Unit E2
4 402 J < J2 Dialysis Rooms 420-432
Step Down Unit
4 403 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
4 404 F < F1 4 Medicine Inpatient Unit Rooms 405-417 Rooms 455-459
Dialysis Rooms 420-432 Step Down Unit Waiting
4 405 E 4 Medicine Inpatient Unit E2
INTERIOR MESSAGE SCHEDULE FOURTH FLOOR
1-21
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.22
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
5 501 E Vending E2
5 502 J > J3 Vending
5 503 J < J2
5 504 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
INTERIOR MESSAGE SCHEDULE FIFTH FLOOR
1-22
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.23
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
5 505 F < F1 Compensation / Pension Clinic
AFGE Local 903 AFGE Local 3399 DAV Lounge Employee Health Fee Basis
MCCR
Service Representatives Vending
5 506 E Compensation / E2 Pension Clinic
INTERIOR MESSAGE SCHEDULE FIFTH FLOOR
1-23
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.24
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
6 601 J < J2
6 602 E 6 Surg / Med E2
6 603 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Café / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic
Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology
Truman Community Living Center
Medicine Inpatient Unit Dialysis
Compensation & Pension Clinic
Intensive Care Unit
Nuclear Medicine
INTERIOR MESSAGE SCHEDULE SIXTH FLOOR
1-24
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
Message Schedule
4.25
Note: Sign company must verify with owner each sign message before production of sign
Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111
FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/
SYMBOL
NOTES REVISED
DATE
6 604 F ^ F2 6 ICU Waiting Restroom
Intensive Care Unit
6 Surg / Med 6 Surg / Med Waiting Vending
6 605 E Intensive Care Unit E1
INTERIOR MESSAGE SCHEDULE SIXTH FLOOR
1-25
VA PROJECT #589A4-23-050 01-01-21
10 21 23 - 1
SECTION 10 21 23
CUBICLE CURTAIN TRACKS
PART 1 - GENERAL
1.1 DESCRIPTION
A. This section specifies cubicle curtain track (C.C.T.).
1.2 RELATED WORK
A. Section 09 51 00, ACOUSTICAL CEILINGS: Acoustical ceiling tile and suspension systems.
1.3 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Shop Drawings: Showing layout of tracks and method of anchorage.
C. Manufacturer's Literature and Data:
1. Cubicle curtain track.
1.4 DELIVERY, STORAGE AND HANDLING
A. Deliver material in original package marked to identify the contents, brand name, and the name of the manufacturer or supplier.
B. Store in dry and protected location. Store so as to not bend or warp the tracks.
C. Do not open packages until contents are needed for installation, unless verification inspection is required.
1.5 WARRANTY
A. Construction Warranty: Cubicle curtain tracks are subject to the terms of the Article “Warranty of Construction,” FAR clause 52.246-21.
1.6 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.
B. ASTM International (ASTM):
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)
B456-17.................Electrodeposited Coatings for Copper Plus
Nickel Plus Chromium and Nickel Plus Chromium
C. Aluminum Association (AA):
DAF 45-09...............Designation System for Aluminum Finishes
10 21 23 - 2
D. American Architectural Manufacturers Association (AAMA):
2603-20.................Voluntary Specification, Performance
Requirements and Test Procedures for Pigmented
Organic Coatings on Aluminum Extrusions and
Panels (with Coil Coating Appendix)
E. The National Association of Architectural Metal Manufacturers (NAAMM):
AMP 500-06 Series.......Metal Finishes Manual
PART 2 - PRODUCTS
2.1 CUBICLE CURTAIN TRACKS
A. Channel Tracks (Surface Mounted Type): Extruded aluminum, ASTM B221M (B221), alloy 6063, temper T5 or T6, channel shaped, with smooth inside raceway for curtain carriers.
B. Curtain Carriers: Nylon carriers, with nylon wheels on metal or nylon axles.
1. Equip each carrier with either stainless steel, chromium plated brass or steel hooks with swivel, or nickel chromium plated brass or stainless steel bead chain
2. Hook for bead chain may be the same material and finish as the bead chain or may be chromium plated steel.
3. Provide 2.2 carriers for every 305 mm (1 foot) of each section of each track length, plus one (1) additional carrier.
C. End Stop Connectors, Ceiling Flanges and Other Accessories: Fabricate from the same material with the same finish as the tracks or from nylon.
D. Hangers and Fittings: Fabricate from the same material with the same finish as the tracks. Hangers may be round or square for channel tracks and round for tubular tracks. Design fittings to be compatible with design of tracks and to safely transmit the track load to the hangers.
E. At end of each section of track, make provision for insertion and removal of carriers. Design to prevent accidental removal of carrier.
Provide operating mechanism shall be removable with common tools.
2.2 FASTENERS
A. Exposed Fasteners, Screws and Bolts: Stainless steel or chromium/nickel plated brass.
10 21 23 - 3
B. Concealed Fasteners, Screws and Bolts: Hot-dip galvanized.
C. Metal Clips: Anchor curtain tracks to exposed grid of lay-in acoustical tile ceilings, with concealed metal (butterfly) type or two piece snap locking type ceiling clip of high strength spring steel.
1. When it is not possible to install the metal ceiling clip, the cubicle curtain track may be screwed to the ceiling grid.
2.3 FINISHES
A. Baked Enamel or Powder Coat Finish: AAMA 2603.
2.4 FABRICATION
A. Weld and grind smooth joints of fabricated components.
B. Form tracks and bends of lengths that will produce the minimum number of joints. Make track sections up to 4877 mm (16 feet) without joints.
Form corner bend on a 305 mm (12 inch) radius.
C. Provide steel anchor plates, supports, and anchors for securing components to building construction.
D. Form flat surface without distortion.
E. Shop assemble components and package complete with anchors and fittings.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install tracks after finish painting and ceiling finishing operations are complete.
B. Install track level and hangers plumb and securely anchor to the ceiling to form a rigid installation.
C. Anchor surface mounted curtain tracks directly to exposed grid of lay-in acoustical tile ceilings with suitable fasteners, spaced approximately 610 mm (24 inches) on center.
D. Anchor surface mounted curtain tracks to concrete, plaster and gypsum board ceilings with a minimum of 3 mm (1/8-inch) diameter fastenings or concealed clips spaced not more than 914 mm (3 feet) on center.
E. Install suspended track 2210 mm (87 inches) above the finished floor, with hangers spaced no more than 1219 mm (4 feet) on center. At ceiling line, provide flange fittings secured to hangers with set screws.
Secure track to walls with flanged fittings and to hangers with special fittings.
F. Fasten end stop caps to prevent them from being forced out by the striking weight of carriers.
10 21 23 - 4
G. Remove damaged or defective components and replace with new components or repair to the original condition.
H. Install track rigid, plumb, level and true, and securely anchored to the overhead construction.
I. Verify that carrier units operate smoothly and easily over the full range of travel.
- - - E N D - - -
10 26 00 - 1
SECTION 10 26 00
WALL AND DOOR PROTECTION
A. This section specifies base rails, handrail/wall guard combinations, corner guards and high impact wall covering.
1.2 RELATED WORK
A. Sustainable Design Requirements: Section 01 81 13, SUSTAINABLE
CONSTRUCTION REQUIREMENTS.
B. Armor plates and kick plates not specified in this section: Section 08
71 00, DOOR HARDWARE.
C. Color and texture of aluminum and resilient material: COLOR SCHEDULE
KEY in drawings.
1.3 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: Manufacturer with a minimum of three (3) years’ experience in providing items of type specified.
1. Obtain wall and door protection from single manufacturer.
B. Installer’s Qualifications: Installers are to have a minimum of three
(3) years’ experience in the installation of units required for this project.
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Shop Drawings: show design and installation details.
C. Manufacturer's Literature and Data:
1. Handrail/Wall Guard Combinations.
2. Wall Guards.
3. Corner Guards.
4. High Impact Wall covering.
D. Test Report: Showing that resilient material complies with specified fire and safety code requirements.
E. Manufacturer’s qualifications.
F. Manufacturer’s warranty.
1.5 DELIVERY AND STORAGE
A. Deliver materials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer.
B. Protect from damage from handling and construction operations before, during and after installation.
10 26 00 - 2
C. Store in a dry environment of approximately 21 degrees C (70 degrees F) for at least 48 hours prior to installation.
1.6 WARRANTY
A. Construction Warranty: Comply with FAR clause 52.246-21 “Warranty of
Construction”.
B. Manufacturer Warranty: Manufacturer shall warranty their wall and door protection for a minimum of five (5) years from date of installation and final acceptance by the Government. Submit manufacturer warranty.
1.7 APPLICABLE PUBLICATIONS
A. publications listed below form a part of this specification to extent referenced. publications are referenced in text by basic designation only.
B. ASTM International (ASTM):
A240/A240M-20...........Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and For General Applications
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)
D256-10(2018)...........Determining the Izod Pendulum Impact Resistance of Plastics
D635-18.................Rate of Burning and/or Extent and Time of
Burning of Self-Supporting Plastics in a
Horizontal Position
E84-20..................Surface Burning Characteristics of Building
Materials
C. Aluminum Association (AA):
DAF 45-09...............Designation System for Aluminum Finishes
D. American Architectural Manufacturers Association (AAMA):
611-14..................Voluntary Specification for Anodized
Architectural Aluminum
E. Code of Federal Regulation (CFR):
40 CFR 59(2020) Subpart D National Volatile Organic Compound
Emission Standards for Architectural Coatings
F. The National Association of Architectural Metal Manufacturers (NAAMM):
AMP 500-06..............Metal Finishes Manual
G. National Fire Protection Association (NFPA):
10 26 00 - 3
80-2019.................Standard for Fire Doors and Other Opening
Protectives
H. SAE International (SAE):
J 1545-2014-10..........Instrumental Color Difference Measurement for
Exterior Finishes, Textiles and Colored Trim.
I. Underwriters Laboratories Inc. (UL):
Annual Issue............Building Materials Directory
PART 2 - PRODUCTS
2.1 MATERIALS
A. Aluminum Extruded: ASTM B221M (B221), Alloy 6063, Temper T5 or T6.
Provide aluminum alloy used for colored anodizing coating as required.
B. Resilient Material:
1. Provide resilient material consisting of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic conforming to the following:
a. Minimum impact resistance of 960.8 N-m/m (18 feet-pounds/square inch) when tested in accordance with ASTM D256 (Izod impact, feet-pounds per inch notched).
b. Class 1 fire rating when tested in accordance with ASTM E84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less.
c. Rated self-extinguishing when tested in accordance with
ASTM D635.
d. Provide material labeled and tested by Underwriters Laboratories or other approved independent testing laboratory.
e. Provide resilient material for protection on fire rated doors and frames assemblies that is listed by the testing laboratory performing the tests.
f. Provide resilient material installed on fire rated wood/steel door and frame assemblies that have been tested on similar type assemblies. Test results of material tested on any other combination of door and frame assembly are not acceptable.
g. Provide integral color with colored components matched in accordance with SAE J 1545 to within plus or minus 1.0 on the
CIE-LCH scales.
2.2 CORNER GUARDS
A. Resilient and stainless steel surface mounted corner guards, angle guards and end guards:
10 26 00 - 4
1. Wing size: Reference drawings for wing sizes and heights.
2. Surface mounted.
3. Reference drawings for locations, manufacturer, size and color.
2.3 WALL GUARDS AND HANDRAILS
A. Resilient Wall Guards and Handrails:
1. Handrail/Wall Guard Combination:
a. Snap-on covers of resilient material, minimum 2 mm (0.078-inch) thick.
b. Free-floating on a continuous, extruded aluminum retainer, minimum 1.82 mm (0.072-inch) thick.
c. Anchor to wall at maximum 762 mm (30 inches) on center.
2. Wall Guards:
a. Snap-on covers of resilient material, minimum 2.54 mm (0.100-inch) thick. Free-floating over 51 mm (2 inch) wide aluminum retainer clips, minimum 2.28 mm (0.090-inch) thick, anchored to wall at maximum 610 mm (24 inches) on center, supporting a continuous aluminum retainer, minimum 1.57 mm (0.062-inch) thick.
3. Provide handrails and wall guards with prefabricated end closure caps, inside and outside corners, concealed splices, cushions, mounting hardware and other accessories as required. End caps and corners to be field adjustable to assure close alignment with handrails and wall guards. Screw or bolt closure caps to aluminum retainer in a concealed manner.
B. Aluminum Wall Guards: Extruded aluminum, closed tubular bumper assembly mounted on wall brackets.
1. Provide wall bumper with factory fabricated end closure caps, and inside and outside corner assemblies, concealed splice plates, and other accessories standard with the manufacturer.
2. Fabricate tubular wall guards from material with a nominal wall thickness of 6.35 mm (0.250-inch), form grooves for and provide two (2) strips of continuous polyvinyl chloride cushion bumper inserts.
3. Fabricate adjustable wall brackets from aluminum having a nominal wall thickness of 5.08 mm (0.20-inch). Fasten bumper to brackets with 6.35 mm (1/4-inch) diameter aluminum or stainless steel bolts with locknuts.
10 26 00 - 5
2.4
2.5 HIGH IMPACT WALL COVERING
A. Provide wall covering/panels consisting of high impact rigid acrylic vinyl or polyvinyl chloride resilient material.
B. Panel sizes to be 0.61 x 1.21 meter (2 x 4 feet).
C. Submit fire rating and extinguishing test results for resilient material.
D. Submit statements attesting that the items comply with specified fire and safety code requirements.
E. Rigid Vinyl Acrylic Wall Covering: Wall covering thickness to be 0.71 mm (0.028 inch).
F. High Impact Wall Panels: Wall panel face and edge thickness to be 0.71 mm (0.028 inch). Panel face to be factory banded to a 9.53 mm (0.375 inch) thick fiberboard core. The backside of the panel is to be laminated with a moisture resistant vapor barrier.
G. Provide adhesive as recommended by the wall covering manufacturer. Provide adhesive with VOC content of 250 g/L or less when calculated according to 40 CFR 59, (EPA Method 24).
2.6 FASTENERS AND ANCHORS
A. Provide fasteners and anchors as required for each specific type of installation.
B. Where type, size, spacing or method of fastening is not shown or specified in construction documents, submit shop drawings showing proposed installation details.
2.7 FINISH
A. Aluminum: In accordance with AA DAF-45.
1. Exposed aluminum: AAMA 611 AA-M12C22A31 chemically etched medium matte, with clear anodic coating, Class II Architectural, .01 mm
(0.4 mil) thick.
2. Concealed aluminum: Mill finish as fabricated, uniform in color and free from surface blemishes.
B. Stainless Steel: In accordance with NAAMM AMP 500 finish Number 4.
C. Resilient Material: Embossed textures and color in accordance with
SAE J1545.
PART 3 - INSTALLATION
3.1 RESILIENT CORNER GUARDS
A. Install corner guards on walls in accordance with manufacturer's instructions.
10 26 00 - 6
3.2 RESILIENT WALL GUARDS HANDRAILS WALL GUARD HANDRAIL COMBINATION
A. Secure guards to walls with mounting brackets and fasteners in accordance with manufacturer's details and instructions.
3.3 HIGH IMPACT WALL COVERING
A. Surfaces to receive protection to be clean, smooth and free of obstructions.
B. Install protectors after frames are in place but preceding installation of doors in accordance with approved shop drawings and manufacturer’s specific instructions.
C. Apply with adhesive in controlled environment according to manufacturer’s recommendations.
D. Protection installed on fire rated doors and frames to be installed according to NFPA 80 and installation procedures listed in UL Building
Materials Directory; or, equal listing by other approved independent testing laboratory establishing the procedures.
10 28 00 - 1
SECTION 10 28 00
TOILET, BATH, AND LAUNDRY ACCESSORIES
A. SUMMARY:
1. Section Includes: Toilet and bath accessories at toilets, baths, locker rooms and other areas indicated on drawings.
2. Provided by Owner; Installed by Contractor (refer to drawings for locations and quantities
a. Paper towel dispenser.
b. Toilet tissue dispenser.
c. Soap dispenser.
d. Sharps Disposals.
e. Glove box holders f.
g. Hand Sanitizer Dispenser
j. Feminine Disposal
3. Provided by Contractor; Installed by Contractor
a. Grab Bars.
b. Robe hooks.
c. Metal framed mirror
1.2 RELATED WORK
A. Section 10 21 23, CUBICLE CURTAIN TRACKS.
B. DIVISION 22, PLUMBING
1.3 APPLICABLE PUBLICATIONS
A. Comply with references to extent specified in this section.
B. American Society of Mechanical Engineers (ASME):
1. B18.6.4-98(R2005) Thread Forming and Thread Cutting Tapping
Screws and Metallic Drive Screws inch.
C. American Welding Society (AWS):
D10.4-86(2000)..........Welding Austenitic Chromium-Nickle Stainless
Steel Piping and Tubing.
D. ASTM International (ASTM):
A269/A269M-15a(2019)....Seamless and Welded Austenitic Stainless Steel
Tubing for General Service.
A312/A312M-19...........Seamless, Welded, and Heavily Cold Worked
Austenitic Stainless Steel Pipes.
10 28 00 - 2
A653/A653M-20...........Steel Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the
Hot-Dip Process.
A666-15.................Annealed or Cold-Worked Austenitic Stainless
Steel Sheet, Strip, Plate, and Flat Bar.
A1011/A1011M-18a........Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved
Formability, and Ultra-High Strength.
B30-20..................Copper Alloys in Ingot Form.
B75/B75M-20.............Seamless Copper Tube.
B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric).
B456-17.................Electrodeposited Coatings of Copper Plus Nickel
Plus Chromium and Nickel Plus Chromium.
B824-17.................General Requirements for Copper Alloy Castings.
C1036-16................Flat Glass.
C1048-18................Heat-Strengthened and Fully Tempered Flat
Glass.
D635-18.................Rate of Burning and/or Extent and Time of
Burning of Plastics in a Horizontal Position.
F446-19.................Grab Bars and Accessories Installed in the
Bathing Area.
E. Federal Specifications (Fed. Spec.):
A-A-3002................Mirror, Glass.
FF-S-107C(2)............Screws, Tapping and Drive.
WW-P-541/8B(1)..........Plumbing Fixtures (Accessories, Land Use).
F. National Architectural Metal Manufacturers(NAAMM):
AMP 500-06..............Metal Finishes Manual.
1.4 SUBMITTALS
A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Submittal Drawings:
1. Show size, configuration, and fabrication, anchorage and installation details.
2. Show mounting locations and heights.
10 28 00 - 3
C. Manufacturer's Literature and Data:
1. Description of each product to be supplied by the GC.
2. Installation instructions.
D. Operation and Maintenance Data:
1. Care instructions for each exposed finish product.
1.5 QUALITY ASSURANCE
A. Manufacturer Qualifications:
1. Regularly manufactures specified products.
1.6 DELIVERY
A. Deliver products in manufacturer's original sealed packaging.
B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.
C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.
1.7 STORAGE AND HANDLING
A. Store products indoors in dry, weathertight facility.
B. Protect products from damage during handling and construction operations.
1.8 WARRANTY
A. Construction Warranty: FAR clause 52.246-21, "Warranty of
Construction."
PART 2 - PRODUCTS
2.1 MATERIALS
A. Aluminum: ASTM B221M (ASTM B221), Alloy 6063-T5 and Alloy 6463-T5.
B. Stainless Steel:
1. Plate Or Sheet: ASTM A666, Type 304, 0.8 mm (0.031 inch) thick unless otherwise specified.
2. Tubing: ASTM A269/A269M, Grade TP 304, seamless or welded.
3. Pipe: ASTM A312/A312M; Grade TP 304.
C. Steel Sheet: ASTM A653/A653M, zinc-coated (galvanized) coating designation G90.
D. Chrome Plating (Service Condition Number SC 2): ASTM B456.
E. Brass Castings: ASTM B30.
F. Copper:
1. Tubing: ASTM B75/B75M.
2. Castings: ASTM B824.
G. Glass:
10 28 00 - 4
1. ASTM C1036, Type 1, Class 1, Quality q2, for mirrors, and for mirror doors in medicine cabinets.
2.2 PRODUCTS - GENERAL
A. Provide each product from one manufacturer.
2.3 PAPER TOWEL DISPENSERS
A.
This is the start of the file's text. The full file is on GovTribe.