P09-Final Specifications VOL-1-Part-9.pdf

PDF 8 MB Posted

Attached to
Z2DA--Renovate and Expand Urology Clinic PN:589A4-23-050
Solicitation number
36C25524R0088
Issued by

About this file

This document is a set of specifications for a federal contract opportunity to renovate and expand the Urology Clinic at the Harry S. Truman Memorial Veterans' Hospital in Columbia, Missouri. The project involves the installation of various signage, cubicle curtain tracks, wall and door protection, toilet and bath accessories, fire extinguisher cabinets, countertops, and seismic restraint requirements for non-structural components. Key details include the project number (589A4-23-050), a description of the required products and services, and applicable industry standards and building codes. The solicitation number is 36C25524R0088 and the contracting agency is the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 15.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Harry S Truman Memorial Veterans Hospital Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

SIGNAGE & GRAPHICS ELEVS.

Fourth Floor South Elevators

Elevation at 4th Floor South Elevator Scale: 1/4” = 1’-0”

Elevation at 4th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”

1/4”=1’ 4th floor elevators - south A elevation

1/4”=1’ 4th floor elevators - south B elevation - adjacent wall

2’-0”

3’-0”

3’-4”3’-0”

CENTEREQ EQ

4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

Title

1/4”=1’ 4th floor elevators - south A elevation

1/4”=1’ 4th floor elevators - south B elevation - adjacent wall

2’-0”

3’-0”

3’-4”3’-0”

CENTEREQ EQ

4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

Title

3.12

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

SIGNAGE & GRAPHICS ELEVS.

Fifth Floor South Elevators

Elevation at 5th Floor South Elevator Scale: 1/4” = 1’-0”

Elevation at 5th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”

1/4”=1’ 5th floor elevators - south A elevation

1/4”=1’ 5th �oor elevators - south B elevation - adjacent wall

2’-0”

3’-0”

CENTEREQ EQ

4”

3’-0” 3’-4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

Title

1/4”=1’ 5th floor elevators - south A elevation

1/4”=1’ 5th �oor elevators - south B elevation - adjacent wall

2’-0”

3’-0”

CENTEREQ EQ

4”

3’-0” 3’-4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

3.13

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

SIGNAGE & GRAPHICS ELEVS.

Sixth Floor South Elevators

Elevation at 6th Floor South Elevator Scale: 1/4” = 1’-0”

Elevation at 6th Floor South Elevator - Adjacent Wall Scale: 1/4” = 1’-0”

1/4”=1’ 6th �oor elevators - south A elevation

2’-0”

3’-0”

1/4”=1’ 6th floor elevators - south B elevation - adjacent wall

CENTEREQ EQ

4”

3’-0” 3’-4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

Title

1/4”=1’ 6th �oor elevators - south A elevation

2’-0”

3’-0”

1/4”=1’ 6th floor elevators - south B elevation - adjacent wall

CENTEREQ EQ

4”

3’-0” 3’-4”

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title

Title Title Title Title Title Title Title Title Title Title

B

Title Title Title Title Title Title Title Title Title Title

Title

Title

Title Title

Title

3.14

SE

CT

IO

N

M

ES

SA

GE

S

CH

ED

UL

E

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.1

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

B E ^ Veterans' Hospital A E2 ^ University Hospital B

B B02 J < J3 University Hospital

Restroom

B03 H Audiology Clinic / Speech Pathology B04 Cardiology / Thoracic Clinic B14 Cysto Urology Lab

Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine B B04 H listed above

B B05 F < F1 Meals on Wheels Nuclear Medicine South Elevators

University Hospital Tunnel

B01

B

INTERIOR MESSAGE SCHEDULE BASEMENT FLOOR

1-1 Price separately per floor

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.2

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

B B06 F < F1 University Hospital Tunnel

Meals on Wheels Nuclear Medicine South Elevators

< J2 Restroom

Meals on Wheels Nuclear Medicine South Elevators

B B08 J < J2 University Hospital Tunnel

North Elevators Restrooms

B B09 J > J3 Meals on Wheels Nuclear Medicine South Elevators

B B10 E ^ South Elevators A E2 ^ University Hospital B

B B11 J > J3 North Elevators Nuclear Medicine Restrooms University Hospital

B B12 J < J2 South Elevators Exit to Smoking Shelter

Engineering Control Center Freight Elevators Sterile Processing Warehouse Meals on Wheels

B B13 F < F1 Patient Effects Smoking Shelter

Meals on Wheels Nuclear Medicine University Hospital Tunnel

B B14 H listed above

B B07 J

INTERIOR MESSAGE SCHEDULE BASEMENT FLOOR

1-2

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.3

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 101 E Red Clinic page 1.8 E1

1 102 E Red Clinic E1

1 103 E White Clinic page 1.8 E1

1 104 E Blue Clinic page 1.8 E1

1 105 J ^ J2 Information

Red Clinic

1 106 H Audiology Clinic / Speech Pathology 3 108 Cardiology / Thoracic Clinic 145 Cysto Urology Lab

Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

1-3

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.4

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 107 F > F1 Blue Clinic Red Clinic White Clinic

Emergency Department Information

1 108 H listed above

1 109 F < F1 Blue Clinic Red Clinic White Clinic

Admissions / Eligibilty Agent Cashier Emergency Department Information Pharmacy Pre-Registration Travel

1 110 E ^ Red Clinic E1

1 111 J > J3 Check-In Red Clinic White Clinic Blue Clinic

1 112 J > J3 Release of Information Pharmacist Counseling

1 113 E ^ Travel Agent Cashier page 1.8 E1

1 114 E ^ Pharmacy page 1.8 E1

1 115 J > J1 Blue Clinic Red Clinic White Clinic

Audiology Clinic / Speech Pathology Details Office Emergency Department Imaging

OEF / OIF / OND

Patient Representative Same Day Surgery

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

1-4

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.5

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 116 E ^ Emergency Department A E1

Red / White / Blue Clinics > ^ Information B < Red / White / Blue Clinics

1 117 E Admissions / Eligibility > A E2 < Admissions / Eligibility B

1 118 G Admissions / Eligibilty 2 121 Agent Cashier

Audiology Clinic / Speech Pathology Blue Clinic Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Details Office Emergency Department Imaging Outpatient Lab

OEF / OIF / OND

Patient Representative Patriot Cafe / Store Pharmacy Police Pre-Registration Release of Information Red Clinic Same Day Surgery Silver Clinic Travel Vending / ATM White Clinic

Auditorium Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Sleep Disorders Center Specialty Clinic Urology

Chapel

EEO

Hospital Director Truman Community Living Center Vending Voluntary Service

1-5

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.6

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 118 4 Medicine Inpatient Unit

121 Step Down Unit continued Dialysis

Compensation & Pension Clinic Fee Basis

MCCR

Service Representatives Vending

6 Intensive Care Unit 6 Surgery / Medicine

Nuclear Medicine Meals on Wheels

1 119 E < Pharmacist Counseling A E2 Pharmacist Counseling > B

1 120 E Information page 1.8 E1

1 121 G listed above

1 122 E Restrooms page 1.8 E2

1 123 J ^ J1 Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Details Office Dental Clinic Imaging Outpatient Lab Patriot Cafe / Store Same Day Surgery Silver Clinic

1 124 E < Admissions / Eligibility J3

1 125 E Pre-Registration E2

1-6

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.7

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 126 J ^ J1

Admissions / Eligibility Agent Cashier Details Office Emergency Department Information

OEF / OIF / OND

Pharmacy Patient Representative Pre-Registration Red / White / Blue Clinics Silver Clinic Travel

1 127 J < J1 Audiology Clininc / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Details Office Imaging Patriot Cafe / Store Same Day Surgery Silver Clinic

Emergency Department Pre-Registration Red / White / Blue Clinics

1 128 E Imaging page 1.8 E1

1 129 J ^ J1 Audiology Clininc / Speech Pathology Cardiology Lab Cysto Urology Lab Same Day Surgery South Elevators

Details Office Patriot Cafe / Store Patient Representative Silver Clinic Vending / ATM

1-7

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.8

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 130 E < Details Office A E2 Details Office > B

1 131 J > J1 Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery

Dental Clinic Outpatient Lab Patriot Cafe / Store Silver Clinic Vending / ATM

1 132 E < Vending / ATM A E2 Vending / ATM > B

1 133 J ^ J1 Dental Clinic Cardiology / Thoracic Clinic Cysto Urology Lab Outpatient Lab Patroit Cafe / Store

Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery Vending / ATM

Silver Clinic

1 134 J ^ J1 Information Main Lobby

Silver Clinic

Audiology Clinic / Speech Pathology Details Office Imaging Same Day Surgery Vending / ATM

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

1-8

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.9

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 135 E Main Lobby E2

1 136 E Silver Clinic E1

1 137 E < Audiology Clinic / Speech Pathology A E1 Audiology Clinic / Speech Pathology > B

1 138 E < Patriot Cafe A E1 Patriot Cafe > B

1 139 E Patriot Store E1

1 140 E ^ South Elevators A E2 ^ Main Lobby B

1 141 E < Surgery A E1 Surgery > B

1 142 J > J3 Audiology Clinic / Speech Pathology Details Office Imaging

1 143 E Same Day Surgery E1

1 144 J < J3 Dental Clinic Outpatient Lab Patriot Cafe / Store South Elevators

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

1-9

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.10

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 145 H listed above

1 146 F ^ F2 Cardiology / Thoracic Clinic Cysto Urology Lab Police

Admissions / Eligibility Agent Cashier Dental Clinic Information Patriot Café / Store Pharmacy Pre-Registration Outpatient Lab Red / White / Blue Clinics Silver Clinic Travel

Audiology Clinic / Speech Pathology Cardio Lab Details Office Emergency Department Imaging

OEF / OIF / OND

Patient Representative Same Day Surgery Vending / ATM

1 147 E ^ Main Lobby E2

1 148 J ^ J1 Dental Clinic

Outpatient Lab

Cardiology / Thoracic Clinic Cysto Urology Lab Police Same Day Surgery

INTERIOR MESSAGE SCHEDULE 1ST FLOOR

1-10

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.11

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 149 J < J3

Patriot Cafe / Store Information / Main Lobby Silver Clinic

Dental Clinic

Outpatient Lab

1 150 E < Outpatient Lab A E1 Outpatient Lab > B

1 151 E Dental Clinic E1

1 152 E Police E2

1 153 J < J2 Patriot Cafe / Store Information / Main Lobby Silver Clinic South Elevators

Cardiology / Thoracic Clinic

1 154 E Cardiology / Thoracic Clinic > E1

1 155 J < J3 Patriot Café / Store Information / Main Lobby Police South Elevators

1 156 E < Cardiology / Thoacic Clinic A E1 Cardiology / Thoracic Clinic > B

1 157 E < Urology Procedures Clinic A E1 Urology Procedures Clinic > B

1-11

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.12

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

1 158 E Cardiology / Thoracic Clinic E1

1 159 J < J3 Information / Main Lobby Patriot Café / Store Silver Clinic

1 160 J > J3 Outpatient Lab Dental Clinic South Elevators

INTERIOR MESSAGE SCHEDULE FIRST FLOOR

1-12

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.13

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

2 201 E Endoscopy Clinic / E1 Pulmonary Function Testing

2 202 E Specialty Clinic E1

2 203 E E2 not used

2 204 F < F1 Bronze Clinic Eye Clinic modify height

> if needed Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic

VIST

2 205 H Audiology Clinic / Speech Pathology 3 207 Cardiology / Thoracic Clinic 231 Cysto Urology Lab

Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

INTERIOR MESSAGE SCHEDULE SECOND FLOOR

1-13

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.14

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

2 206 F < F1 Endpscopy Clinic / Pulmonary Function Testing Specialty Clinic

VIST

Bronze Clinic Eye Clinic ENT Clinic Urology (Coumadin) Warfarin Clinic

2 207 H listed above

2 208 E Restroom page 1.8 E1

2 209 E Eye Clinic E1

2 210 J ^ J1 Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic

VIST

Eye Clinic

Bronze Clinic Restroom

2 211 I < Endoscopy Clinic / Pulmonary Function Testing Eye Clinic Specialty Clinic

VIST

Bronze Clinic Restroom Urology

2 212 J ^ J2 Restroom

Bronze Clinic

INTERIOR MESSAGE SCHEDULE SECOND FLOOR

1-14

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.15

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

2 213 E Bronze Clinic E1

2 214 J ^ J2 Bronze Clinic Eye Clinic Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic

VIST

2 215 E Optical Shop E2

2 216 J < J2 Green Team Clinics

2 217 J < J3 Green Team Clinics

Physical Medicine / Rehabilitation

2 218 E Green Clinic E1

2 219 E Green Clinic > E1

2 220 J < J2 Bronze Clinic Eye Clinic Endoscopy Clinic / Pulmonary Function Testing Specialty Clinic

VIST

Auditorium Physical Medicine / Rehabilitation

INTERIOR MESSAGE SCHEDULE SECOND FLOOR

1-15

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.16

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

2 221 J ^ J2 Auditorium EEG Lab Prosthetics South Elevators

Physical Medicine / Rehabilitation Occupational Therapy / Physical Therapy

2 222 E Physical Medicine / E1 Rehabilitation Occupational Therapy / Physical Therapy

2 223 E Physical Medicine / E1 Rehabilitation

2 224 J < J3 Brace & Amputee Clinic SCI & MS Clinic

2 225 J < J2 Occupational Therapy / Physical Therapy

Cardiac Rehabilitation Sleep Disorders Center

2 226 E Green Team Clinics E1

2 227 E Green Clinic E1

2 228 E Green Team Clinics E1

2 229 J > J2 Green Team Clinics

INTERIOR MESSAGE SCHEDULE SECOND FLOOR

1-16

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.17

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

2 230 E Green Clinic > E2

2 231 H listed above

2 232 F ^ F2 Auditorium

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Physical Medicine / Rehabilitation Specialty Clinic

Green Clinic

2 233 J ^ J1 Auditorium

Physical Medicine / Rehabilitation Occupational Therapy / Physical Therapy

Green Clinic South Elevators

2 234 E Physical Medicine / E1 Rehabilitation

Occupational Therapy / Physical Therapy

2 235 E < Cardiac Rehabilitation A E1 Cardiac Rehabilitation > B

2 236 E < Sleep Disorder Clinic A E1 Sleep Disorder Clinic > B

2 237 E Auditorium E1

2 238 J ^ J2 Physical Medicine / Rehabilitation Occupational Theraphy / Physical Therapy

Prosthetics Cardiac Rehabilitation Sleep Disorders Center

INTERIOR MESSAGE SCHEDULE SECOND FLOOR

1-17

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.18

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

3 301 J > J3

3 302 J > J2 Vending Truman Community Living Center

3 303 E Vending E2

3 304 J ^ J2 Vending

South Elevators

3 305 E ? E1

3 306 J < J2 Chapel Craft Room Home Based Primary Care Medical Library Medical Media

Vending

3 307 J ^ J3 Public Telephone Vending

INTERIOR MESSAGE SCHEDULE THIRD FLOOR

1-18

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.19

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

3 308 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine / Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

3 309 F ^ F2 Chapel Human Resources Medical Library Nursing Education Voluntary Service

Truman Community Living Center

EEO

Home Based Primary Care Hospital Director Medical Media Vending

INTERIOR MESSAGE SCHEDULE THIRD FLOOR

1-19

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.20

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

3 310 J ^ J2 Hospital Director Medical Media Vending

Chapel Human Resources Medical Library Nursing Education Voluntary Service

3 311 E Human Resources E1

3 312 J > J3 Chapel Home Based Primary Care Medical Library Medical Media Nursing Education

3 313 J > J3 Home Based Primary Care Medical Library Medical Media Nursing Education

3 314 J > J2 Home Based Primary Care

Chapel Medical Library

INTERIOR MESSAGE SCHEDULE THIRD FLOOR

1-20

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.21

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

4 401 E Step Down Unit E2

4 402 J < J2 Dialysis Rooms 420-432

Step Down Unit

4 403 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

4 404 F < F1 4 Medicine Inpatient Unit Rooms 405-417 Rooms 455-459

Dialysis Rooms 420-432 Step Down Unit Waiting

4 405 E 4 Medicine Inpatient Unit E2

INTERIOR MESSAGE SCHEDULE FOURTH FLOOR

1-21

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.22

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

5 501 E Vending E2

5 502 J > J3 Vending

5 503 J < J2

5 504 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Cafe / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

INTERIOR MESSAGE SCHEDULE FIFTH FLOOR

1-22

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.23

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

5 505 F < F1 Compensation / Pension Clinic

AFGE Local 903 AFGE Local 3399 DAV Lounge Employee Health Fee Basis

MCCR

Service Representatives Vending

5 506 E Compensation / E2 Pension Clinic

INTERIOR MESSAGE SCHEDULE FIFTH FLOOR

1-23

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.24

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

6 601 J < J2

6 602 E 6 Surg / Med E2

6 603 H Audiology Clinic / Speech Pathology Cardiology / Thoracic Clinic Cysto Urology Lab Dental Clinic Emergency Clinic Imaging Outpatient Lab Patriot Café / Store Red / White / Blue Clinics Same Day Surgery Silver Clinic

Bronze Clinic Endoscopy Center / Pulmonary Function Testing Eye Clinic Green Clinic Physical Medicine & Rehabilitation Specialty Clinic Urology

Truman Community Living Center

Medicine Inpatient Unit Dialysis

Compensation & Pension Clinic

Intensive Care Unit

Nuclear Medicine

INTERIOR MESSAGE SCHEDULE SIXTH FLOOR

1-24

Columbia, Missouri Improve Interior Wayfinding

Date: July 22, 2014 Project: 1122.01

1 Memorial Drive, Suite 1800

St. Louis, Missouri 63102

Phone: (314) 621 4343

Fax: (314) 621 0261

Email: info@fox-arch.com

Message Schedule

4.25

Note: Sign company must verify with owner each sign message before production of sign

Harry S. Truman Memorial Veterans' Hospital - Columbia, Missouri 589A4-11-111

FLOOR LOCATION SIGN TYPE SIGN TEXT SIDE QUANTITY LAYOUT/

SYMBOL

NOTES REVISED

DATE

6 604 F ^ F2 6 ICU Waiting Restroom

Intensive Care Unit

6 Surg / Med 6 Surg / Med Waiting Vending

6 605 E Intensive Care Unit E1

INTERIOR MESSAGE SCHEDULE SIXTH FLOOR

1-25

VA PROJECT #589A4-23-050 01-01-21

10 21 23 - 1

SECTION 10 21 23

CUBICLE CURTAIN TRACKS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies cubicle curtain track (C.C.T.).

1.2 RELATED WORK

A. Section 09 51 00, ACOUSTICAL CEILINGS: Acoustical ceiling tile and suspension systems.

1.3 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Shop Drawings: Showing layout of tracks and method of anchorage.

C. Manufacturer's Literature and Data:

1. Cubicle curtain track.

1.4 DELIVERY, STORAGE AND HANDLING

A. Deliver material in original package marked to identify the contents, brand name, and the name of the manufacturer or supplier.

B. Store in dry and protected location. Store so as to not bend or warp the tracks.

C. Do not open packages until contents are needed for installation, unless verification inspection is required.

1.5 WARRANTY

A. Construction Warranty: Cubicle curtain tracks are subject to the terms of the Article “Warranty of Construction,” FAR clause 52.246-21.

1.6 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation only.

B. ASTM International (ASTM):

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)

B456-17.................Electrodeposited Coatings for Copper Plus

Nickel Plus Chromium and Nickel Plus Chromium

C. Aluminum Association (AA):

DAF 45-09...............Designation System for Aluminum Finishes

10 21 23 - 2

D. American Architectural Manufacturers Association (AAMA):

2603-20.................Voluntary Specification, Performance

Requirements and Test Procedures for Pigmented

Organic Coatings on Aluminum Extrusions and

Panels (with Coil Coating Appendix)

E. The National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06 Series.......Metal Finishes Manual

PART 2 - PRODUCTS

2.1 CUBICLE CURTAIN TRACKS

A. Channel Tracks (Surface Mounted Type): Extruded aluminum, ASTM B221M (B221), alloy 6063, temper T5 or T6, channel shaped, with smooth inside raceway for curtain carriers.

B. Curtain Carriers: Nylon carriers, with nylon wheels on metal or nylon axles.

1. Equip each carrier with either stainless steel, chromium plated brass or steel hooks with swivel, or nickel chromium plated brass or stainless steel bead chain

2. Hook for bead chain may be the same material and finish as the bead chain or may be chromium plated steel.

3. Provide 2.2 carriers for every 305 mm (1 foot) of each section of each track length, plus one (1) additional carrier.

C. End Stop Connectors, Ceiling Flanges and Other Accessories: Fabricate from the same material with the same finish as the tracks or from nylon.

D. Hangers and Fittings: Fabricate from the same material with the same finish as the tracks. Hangers may be round or square for channel tracks and round for tubular tracks. Design fittings to be compatible with design of tracks and to safely transmit the track load to the hangers.

E. At end of each section of track, make provision for insertion and removal of carriers. Design to prevent accidental removal of carrier.

Provide operating mechanism shall be removable with common tools.

2.2 FASTENERS

A. Exposed Fasteners, Screws and Bolts: Stainless steel or chromium/nickel plated brass.

10 21 23 - 3

B. Concealed Fasteners, Screws and Bolts: Hot-dip galvanized.

C. Metal Clips: Anchor curtain tracks to exposed grid of lay-in acoustical tile ceilings, with concealed metal (butterfly) type or two piece snap locking type ceiling clip of high strength spring steel.

1. When it is not possible to install the metal ceiling clip, the cubicle curtain track may be screwed to the ceiling grid.

2.3 FINISHES

A. Baked Enamel or Powder Coat Finish: AAMA 2603.

2.4 FABRICATION

A. Weld and grind smooth joints of fabricated components.

B. Form tracks and bends of lengths that will produce the minimum number of joints. Make track sections up to 4877 mm (16 feet) without joints.

Form corner bend on a 305 mm (12 inch) radius.

C. Provide steel anchor plates, supports, and anchors for securing components to building construction.

D. Form flat surface without distortion.

E. Shop assemble components and package complete with anchors and fittings.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install tracks after finish painting and ceiling finishing operations are complete.

B. Install track level and hangers plumb and securely anchor to the ceiling to form a rigid installation.

C. Anchor surface mounted curtain tracks directly to exposed grid of lay-in acoustical tile ceilings with suitable fasteners, spaced approximately 610 mm (24 inches) on center.

D. Anchor surface mounted curtain tracks to concrete, plaster and gypsum board ceilings with a minimum of 3 mm (1/8-inch) diameter fastenings or concealed clips spaced not more than 914 mm (3 feet) on center.

E. Install suspended track 2210 mm (87 inches) above the finished floor, with hangers spaced no more than 1219 mm (4 feet) on center. At ceiling line, provide flange fittings secured to hangers with set screws.

Secure track to walls with flanged fittings and to hangers with special fittings.

F. Fasten end stop caps to prevent them from being forced out by the striking weight of carriers.

10 21 23 - 4

G. Remove damaged or defective components and replace with new components or repair to the original condition.

H. Install track rigid, plumb, level and true, and securely anchored to the overhead construction.

I. Verify that carrier units operate smoothly and easily over the full range of travel.

- - - E N D - - -

10 26 00 - 1

SECTION 10 26 00

WALL AND DOOR PROTECTION

A. This section specifies base rails, handrail/wall guard combinations, corner guards and high impact wall covering.

1.2 RELATED WORK

A. Sustainable Design Requirements: Section 01 81 13, SUSTAINABLE

CONSTRUCTION REQUIREMENTS.

B. Armor plates and kick plates not specified in this section: Section 08

71 00, DOOR HARDWARE.

C. Color and texture of aluminum and resilient material: COLOR SCHEDULE

KEY in drawings.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Manufacturer with a minimum of three (3) years’ experience in providing items of type specified.

1. Obtain wall and door protection from single manufacturer.

B. Installer’s Qualifications: Installers are to have a minimum of three

(3) years’ experience in the installation of units required for this project.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Shop Drawings: show design and installation details.

C. Manufacturer's Literature and Data:

1. Handrail/Wall Guard Combinations.

2. Wall Guards.

3. Corner Guards.

4. High Impact Wall covering.

D. Test Report: Showing that resilient material complies with specified fire and safety code requirements.

E. Manufacturer’s qualifications.

F. Manufacturer’s warranty.

1.5 DELIVERY AND STORAGE

A. Deliver materials to the site in original sealed packages or containers marked with the name and brand, or trademark of the manufacturer.

B. Protect from damage from handling and construction operations before, during and after installation.

10 26 00 - 2

C. Store in a dry environment of approximately 21 degrees C (70 degrees F) for at least 48 hours prior to installation.

1.6 WARRANTY

A. Construction Warranty: Comply with FAR clause 52.246-21 “Warranty of

Construction”.

B. Manufacturer Warranty: Manufacturer shall warranty their wall and door protection for a minimum of five (5) years from date of installation and final acceptance by the Government. Submit manufacturer warranty.

1.7 APPLICABLE PUBLICATIONS

A. publications listed below form a part of this specification to extent referenced. publications are referenced in text by basic designation only.

B. ASTM International (ASTM):

A240/A240M-20...........Chromium and Chromium-Nickel Stainless Steel

Plate, Sheet, and Strip for Pressure Vessels and For General Applications

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Shapes, and Tubes (Metric)

D256-10(2018)...........Determining the Izod Pendulum Impact Resistance of Plastics

D635-18.................Rate of Burning and/or Extent and Time of

Burning of Self-Supporting Plastics in a

Horizontal Position

E84-20..................Surface Burning Characteristics of Building

Materials

C. Aluminum Association (AA):

DAF 45-09...............Designation System for Aluminum Finishes

D. American Architectural Manufacturers Association (AAMA):

611-14..................Voluntary Specification for Anodized

Architectural Aluminum

E. Code of Federal Regulation (CFR):

40 CFR 59(2020) Subpart D National Volatile Organic Compound

Emission Standards for Architectural Coatings

F. The National Association of Architectural Metal Manufacturers (NAAMM):

AMP 500-06..............Metal Finishes Manual

G. National Fire Protection Association (NFPA):

10 26 00 - 3

80-2019.................Standard for Fire Doors and Other Opening

Protectives

H. SAE International (SAE):

J 1545-2014-10..........Instrumental Color Difference Measurement for

Exterior Finishes, Textiles and Colored Trim.

I. Underwriters Laboratories Inc. (UL):

Annual Issue............Building Materials Directory

PART 2 - PRODUCTS

2.1 MATERIALS

A. Aluminum Extruded: ASTM B221M (B221), Alloy 6063, Temper T5 or T6.

Provide aluminum alloy used for colored anodizing coating as required.

B. Resilient Material:

1. Provide resilient material consisting of high impact resistant extruded acrylic vinyl, polyvinyl chloride, or injection molded thermal plastic conforming to the following:

a. Minimum impact resistance of 960.8 N-m/m (18 feet-pounds/square inch) when tested in accordance with ASTM D256 (Izod impact, feet-pounds per inch notched).

b. Class 1 fire rating when tested in accordance with ASTM E84, having a maximum flame spread of 25 and a smoke developed rating of 450 or less.

c. Rated self-extinguishing when tested in accordance with

ASTM D635.

d. Provide material labeled and tested by Underwriters Laboratories or other approved independent testing laboratory.

e. Provide resilient material for protection on fire rated doors and frames assemblies that is listed by the testing laboratory performing the tests.

f. Provide resilient material installed on fire rated wood/steel door and frame assemblies that have been tested on similar type assemblies. Test results of material tested on any other combination of door and frame assembly are not acceptable.

g. Provide integral color with colored components matched in accordance with SAE J 1545 to within plus or minus 1.0 on the

CIE-LCH scales.

2.2 CORNER GUARDS

A. Resilient and stainless steel surface mounted corner guards, angle guards and end guards:

10 26 00 - 4

1. Wing size: Reference drawings for wing sizes and heights.

2. Surface mounted.

3. Reference drawings for locations, manufacturer, size and color.

2.3 WALL GUARDS AND HANDRAILS

A. Resilient Wall Guards and Handrails:

1. Handrail/Wall Guard Combination:

a. Snap-on covers of resilient material, minimum 2 mm (0.078-inch) thick.

b. Free-floating on a continuous, extruded aluminum retainer, minimum 1.82 mm (0.072-inch) thick.

c. Anchor to wall at maximum 762 mm (30 inches) on center.

2. Wall Guards:

a. Snap-on covers of resilient material, minimum 2.54 mm (0.100-inch) thick. Free-floating over 51 mm (2 inch) wide aluminum retainer clips, minimum 2.28 mm (0.090-inch) thick, anchored to wall at maximum 610 mm (24 inches) on center, supporting a continuous aluminum retainer, minimum 1.57 mm (0.062-inch) thick.

3. Provide handrails and wall guards with prefabricated end closure caps, inside and outside corners, concealed splices, cushions, mounting hardware and other accessories as required. End caps and corners to be field adjustable to assure close alignment with handrails and wall guards. Screw or bolt closure caps to aluminum retainer in a concealed manner.

B. Aluminum Wall Guards: Extruded aluminum, closed tubular bumper assembly mounted on wall brackets.

1. Provide wall bumper with factory fabricated end closure caps, and inside and outside corner assemblies, concealed splice plates, and other accessories standard with the manufacturer.

2. Fabricate tubular wall guards from material with a nominal wall thickness of 6.35 mm (0.250-inch), form grooves for and provide two (2) strips of continuous polyvinyl chloride cushion bumper inserts.

3. Fabricate adjustable wall brackets from aluminum having a nominal wall thickness of 5.08 mm (0.20-inch). Fasten bumper to brackets with 6.35 mm (1/4-inch) diameter aluminum or stainless steel bolts with locknuts.

10 26 00 - 5

2.4

2.5 HIGH IMPACT WALL COVERING

A. Provide wall covering/panels consisting of high impact rigid acrylic vinyl or polyvinyl chloride resilient material.

B. Panel sizes to be 0.61 x 1.21 meter (2 x 4 feet).

C. Submit fire rating and extinguishing test results for resilient material.

D. Submit statements attesting that the items comply with specified fire and safety code requirements.

E. Rigid Vinyl Acrylic Wall Covering: Wall covering thickness to be 0.71 mm (0.028 inch).

F. High Impact Wall Panels: Wall panel face and edge thickness to be 0.71 mm (0.028 inch). Panel face to be factory banded to a 9.53 mm (0.375 inch) thick fiberboard core. The backside of the panel is to be laminated with a moisture resistant vapor barrier.

G. Provide adhesive as recommended by the wall covering manufacturer. Provide adhesive with VOC content of 250 g/L or less when calculated according to 40 CFR 59, (EPA Method 24).

2.6 FASTENERS AND ANCHORS

A. Provide fasteners and anchors as required for each specific type of installation.

B. Where type, size, spacing or method of fastening is not shown or specified in construction documents, submit shop drawings showing proposed installation details.

2.7 FINISH

A. Aluminum: In accordance with AA DAF-45.

1. Exposed aluminum: AAMA 611 AA-M12C22A31 chemically etched medium matte, with clear anodic coating, Class II Architectural, .01 mm

(0.4 mil) thick.

2. Concealed aluminum: Mill finish as fabricated, uniform in color and free from surface blemishes.

B. Stainless Steel: In accordance with NAAMM AMP 500 finish Number 4.

C. Resilient Material: Embossed textures and color in accordance with

SAE J1545.

PART 3 - INSTALLATION

3.1 RESILIENT CORNER GUARDS

A. Install corner guards on walls in accordance with manufacturer's instructions.

10 26 00 - 6

3.2 RESILIENT WALL GUARDS HANDRAILS WALL GUARD HANDRAIL COMBINATION

A. Secure guards to walls with mounting brackets and fasteners in accordance with manufacturer's details and instructions.

3.3 HIGH IMPACT WALL COVERING

A. Surfaces to receive protection to be clean, smooth and free of obstructions.

B. Install protectors after frames are in place but preceding installation of doors in accordance with approved shop drawings and manufacturer’s specific instructions.

C. Apply with adhesive in controlled environment according to manufacturer’s recommendations.

D. Protection installed on fire rated doors and frames to be installed according to NFPA 80 and installation procedures listed in UL Building

Materials Directory; or, equal listing by other approved independent testing laboratory establishing the procedures.

10 28 00 - 1

SECTION 10 28 00

TOILET, BATH, AND LAUNDRY ACCESSORIES

A. SUMMARY:

1. Section Includes: Toilet and bath accessories at toilets, baths, locker rooms and other areas indicated on drawings.

2. Provided by Owner; Installed by Contractor (refer to drawings for locations and quantities

a. Paper towel dispenser.

b. Toilet tissue dispenser.

c. Soap dispenser.

d. Sharps Disposals.

e. Glove box holders f.

g. Hand Sanitizer Dispenser

j. Feminine Disposal

3. Provided by Contractor; Installed by Contractor

a. Grab Bars.

b. Robe hooks.

c. Metal framed mirror

1.2 RELATED WORK

A. Section 10 21 23, CUBICLE CURTAIN TRACKS.

B. DIVISION 22, PLUMBING

1.3 APPLICABLE PUBLICATIONS

A. Comply with references to extent specified in this section.

B. American Society of Mechanical Engineers (ASME):

1. B18.6.4-98(R2005) Thread Forming and Thread Cutting Tapping

Screws and Metallic Drive Screws inch.

C. American Welding Society (AWS):

D10.4-86(2000)..........Welding Austenitic Chromium-Nickle Stainless

Steel Piping and Tubing.

D. ASTM International (ASTM):

A269/A269M-15a(2019)....Seamless and Welded Austenitic Stainless Steel

Tubing for General Service.

A312/A312M-19...........Seamless, Welded, and Heavily Cold Worked

Austenitic Stainless Steel Pipes.

10 28 00 - 2

A653/A653M-20...........Steel Sheet, Zinc-Coated (Galvanized) or

Zinc-Iron Alloy-Coated (Galvannealed) by the

Hot-Dip Process.

A666-15.................Annealed or Cold-Worked Austenitic Stainless

Steel Sheet, Strip, Plate, and Flat Bar.

A1011/A1011M-18a........Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved

Formability, and Ultra-High Strength.

B30-20..................Copper Alloys in Ingot Form.

B75/B75M-20.............Seamless Copper Tube.

B221-14.................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.

B221M-13................Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric).

B456-17.................Electrodeposited Coatings of Copper Plus Nickel

Plus Chromium and Nickel Plus Chromium.

B824-17.................General Requirements for Copper Alloy Castings.

C1036-16................Flat Glass.

C1048-18................Heat-Strengthened and Fully Tempered Flat

Glass.

D635-18.................Rate of Burning and/or Extent and Time of

Burning of Plastics in a Horizontal Position.

F446-19.................Grab Bars and Accessories Installed in the

Bathing Area.

E. Federal Specifications (Fed. Spec.):

A-A-3002................Mirror, Glass.

FF-S-107C(2)............Screws, Tapping and Drive.

WW-P-541/8B(1)..........Plumbing Fixtures (Accessories, Land Use).

F. National Architectural Metal Manufacturers(NAAMM):

AMP 500-06..............Metal Finishes Manual.

1.4 SUBMITTALS

A. Submittal Procedures: Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. Submittal Drawings:

1. Show size, configuration, and fabrication, anchorage and installation details.

2. Show mounting locations and heights.

10 28 00 - 3

C. Manufacturer's Literature and Data:

1. Description of each product to be supplied by the GC.

2. Installation instructions.

D. Operation and Maintenance Data:

1. Care instructions for each exposed finish product.

1.5 QUALITY ASSURANCE

A. Manufacturer Qualifications:

1. Regularly manufactures specified products.

1.6 DELIVERY

A. Deliver products in manufacturer's original sealed packaging.

B. Mark packaging, legibly. Indicate manufacturer's name or brand, type, color, production run number, and manufacture date.

C. Before installation, return or dispose of products within distorted, damaged, or opened packaging.

1.7 STORAGE AND HANDLING

A. Store products indoors in dry, weathertight facility.

B. Protect products from damage during handling and construction operations.

1.8 WARRANTY

A. Construction Warranty: FAR clause 52.246-21, "Warranty of

Construction."

PART 2 - PRODUCTS

2.1 MATERIALS

A. Aluminum: ASTM B221M (ASTM B221), Alloy 6063-T5 and Alloy 6463-T5.

B. Stainless Steel:

1. Plate Or Sheet: ASTM A666, Type 304, 0.8 mm (0.031 inch) thick unless otherwise specified.

2. Tubing: ASTM A269/A269M, Grade TP 304, seamless or welded.

3. Pipe: ASTM A312/A312M; Grade TP 304.

C. Steel Sheet: ASTM A653/A653M, zinc-coated (galvanized) coating designation G90.

D. Chrome Plating (Service Condition Number SC 2): ASTM B456.

E. Brass Castings: ASTM B30.

F. Copper:

1. Tubing: ASTM B75/B75M.

2. Castings: ASTM B824.

G. Glass:

10 28 00 - 4

1. ASTM C1036, Type 1, Class 1, Quality q2, for mirrors, and for mirror doors in medicine cabinets.

2.2 PRODUCTS - GENERAL

A. Provide each product from one manufacturer.

2.3 PAPER TOWEL DISPENSERS

A.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .