P09-Drawings-Part-2.pdf

PDF 8 MB Posted

Attached to
Z2DA--Renovate and Expand Urology Clinic PN:589A4-23-050
Solicitation number
36C25524R0088
Issued by

About this file

This document appears to be a set of drawings and specifications for the renovation and expansion of the Urology Clinic at a Department of Veterans Affairs (VA) facility in Columbia, Missouri. The project involves modifying the existing layout, adding new wall protection and other finishes, and updating the fire sprinkler, fire alarm, mechanical, and plumbing systems. Key details include:

The project is solicitation number 36C25524R0088, with project number 589A4-23-050, and is being procured by the VA's Veterans Integrated Service Network 15. The renovation will take place in phases to allow the clinic to remain operational. The drawings indicate the areas of demolition and new construction, with details on the wall protection, millwork, signage, fire suppression, HVAC, and plumbing systems required. The project appears to be a full facility renovation, with the contractor responsible for coordinating new systems with the existing conditions.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FEC

WALL PROTECTION LEGEND

CORNER GUARD

END WALL GUARD

ANGLE WALL GUARD

HANDRAIL WITH CRASH RAIL (HR-1, CR-X)

KEY:

CG-X.X

REFERS TO COLOR, REF CSK

REFERS TO HEIGHT, REF CSK

GENERAL NOTES

1. INSTALL ALL WALL CORNER GUARDS, END GUARDS, & ANGLE GUARDS

ABOVE FLOOR BASE.

2. INSTALL ALL RIGID VINYL SHEET ABOVE FLOOR BASE.

3. REFER TO COLOR SCHEDULE KEY AND SPECIFICATIONS MANUAL FOR

WALL PROTECTION MANUFACTURER, SIZE & COLOR.

4. "F" STANDS FOR FULL HEIGHT.

RIGID WALL COVERING WITH CRASH RAIL

AND WALL GUARD (RWC-2.3, CR-2, WG-1)

RIGID WALL COVERING (RWC-X.X)

CRASH RAIL (CR-X)

CORR.

C1C18

TLT.

C189

URO

PROCEDURE

C184

TLT.

C182

EXAM #7

C101G

EXAM #5

C101E

EXAM #3

C101C

EXAM #1

C101A

TLT.

C177A

NAVIGATOR

SWAMP

D150

TLT.

D150A

WAITING

C177

CORR.

C1D5

MSA

C178

CORR.

C1C19

CORR.

C1C19

CLEAN

UTILITY

C179

EXAM #2

C101B

TLT.

C181

NURSE

ALCOVE

HALL

C101

HALL

C101

EXAM #4

C101D

EXAM #6

C101F

NAVIGATOR

C183

TLT.

C180

EQUIP.

URO

PROCEDURE

C186

STOR.

C185

PROVIDER

SWAMP

C187

CORR.

C1C18

CORR.

C1C18

S U

P P

L

IE

S

SOILED

C188

ALCOVE

EQUIP.

CG-2.F

CG-2.F

RWC-2.4

RWC-2.4

EG-1.F

EG-2.F

EG-2.F

HR-1, CR-1

RWC-2.4

R W

C -2

.4

R W

C -2

.4

R W

C -2

.4

CG-2.F

RWC-2.4

CG-1.F

R W

C -2

.4

RWC-2.4

CG-2.F

R W

C -2

.4

RWC-2.4

RWC-2.4

RWC-2.4

CG-2.F

R W

C -2

.4

CG-1.F

HR-1, CR-1HR-1, CR-1

CG-2.F

CG-1.F

HR-1, CR-1HR-1, CR-1HR-1, CR-1

HR-1, CR-1HR-1, CR-1

CG-1.F CG-1.F

HR-1, CR-1 HR-1, CR-1 HR-1, CR-1

CG-1.F

CG-2.FCG-2.F

CG-1.F

CG-1.F

CG-1.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

RWC-2.4

H R

-1 C

R -1

CG-1.F

CG-1.F

CG-1.F

CG-1.F

CG-2.F

R W

C -2

.4

RWC-2.4

R W

C -2

.4

CG-2.F CG-2.F

CG-2.F

RWC-2.4

RWC-2.4

RWC-2.4

RWC-2.4

ELEC

D194

CR-2

CR-2

CR-2CR-2

CR-2

C R

-2

C R

-2

CR-2

CR-2

CR-2

CR-2

C R

-2

CR-2

CG-1.F

C1C2

C192

C191

C1C9 C1C9 C1D5 C1D9

C1D9

C1D1

C1C1C1C2

C105

C103 C102

D151

D100A

#6

A .F

.F

R E

F C

S K

GYP. BD.

FASTENER

CONTINUOUS

ALUMINUM RETAINER

MOUNTING BRACKET

2" 1 1/2"

3 1/2"

CLEAR SILICONE CAULK

AT TOP OF BRACKET &

WALL JOINT

VINYL COVER

1/2" BRACKET SPACER

MACHINE SCREW WITH

SERRATED FLANGE

NUT

/1

N T

S

TOP CAP, REF SPEC & CSK

RIGID WALL COVERING (RWC) OR

HYGIENIC WALL CLADDING (HWC) AS

SCHEDULED

CLEAR SILICONE CAULK AT

TOP CAP & WALL JOINT

A .F

.F

R E

F C

S K

GYP. BD.

RIGID WALL COVERING

(RWC) WHERE OCCURS

GYP. BD.

HIGH-IMPACT

RESILIENT COVER

FASTENER

CONTINUOUS

ALUMINUM

RETAINER

BLOCK'G

AS REQ'D

CONTINUOUS

IMPACT BUMPER

CLEAR SILICONE CAULK

AT TOP OF CRASH RAIL

& WALL JOINT

BASE AS

SCHEDULED

A .F

.F

R E

F C

S K

HIGH-IMPACT

RESILIENT COVER

FASTENER

CONTINUOUS

ALUMINUM

RETAINER

BLOCK'G

AS REQ'D

CONTINUOUS

IMPACT BUMPER

/4

CLEAR SILICONE CAULK AT

TOP OF WALL GUARD &

WALL JOINT

RIGID WALL COVERING

(RWC) AS SCHEDULED

GYP. BD.

RIGID WALL COVERING

(RWC) AS SCHEDULED

INSTALL RESILIENT BASE TO

WP W/ SPECIAL ADHESIVE AS

RECOMMENDED BY

MANUFACTUER

INSTALL BOTTOM OF WP

1/16" FROM FINISHED

FLOOR

GYP. BD.

GYP. BD.

METAL COVE CAP

COVE STICK AS REQ'D

BY MANUFACTURER

SHEET FLOORING

MATERIAL, REF.

FINISH SCHED. & CSK

CLEAR SILICONE CAULK AT

COVE CAP & BOTTOM OF RWC

RIGID WALL COVERING

(RWC) AS SCHEDULED

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h in ch o ne fo ot on e q ua rt er i nc h th re e e ig ht hs o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e a nd on e h al f in ch es o ne f oo t th re e in es ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI301

WALL PROTECTION PLAN - 1ST FLOOR

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

1/4" = 1'-0" D2

WALL PROTECTION PLAN - 1ST FLOOR

N

0' 2'-8" 5'-4" 10'-8"

3" = 1'-0" A5

DETAIL - HANDRAIL

6" = 1'-0"

A4

DETAIL - WALL PROTECTION TOP CAP

3" = 1'-0" B4

DETAIL - CRASH RAIL

3" = 1'-0" A3

DETAIL - WALL GUARD

6" = 1'-0" B3

DETAIL - WALL PROT AT RESILIENT BASE

6" = 1'-0"

B5

DETAIL - WALL PROT AT COVE BASE

# Revision Date

A. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS

AT THE PROJECT SITE.

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

REFER TO GI002 AND GI003 SHEETS FOR MOUNTING HEIGHTS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

10053E

M1801

26.01 12.02

M1801

M1801 26.01

26.01

12.02 12.02

M1803

M3073

10058E

F3200

A5108

10054E

26.01

26.01

B6

AI501

D6

AI501

D5

AI501

A5107

A5077

A5145

A1012

A5082

A5075

6.40D

30" 33" FILLER

31" 33" FILLER

26.01

26.01

6.40E

6.40B

6.40A

9.09

6.40E

26.31

12.22

26.01

26.01

D5

AI501

D6

AI501

B6

AI501

6.40D

26.01

A5077

A5107

A5145

A1012

A5082

A5075

M3073

FILLER 30" 30"

FILLER 30" 30"

9.09 6.40E

9.07

6.40E

26.31 26.01

6.40B

6.40A

12.22

CG-1.F

M1801

M1801

10047E

A1015

10047E

10048E 10048E

A1015 10046E

10043E

26.01

26.01

12.02 9.07

M1801 M1801

10047E

A1015 A1015

10053E

26.01

12.0212.02

A1015

10047E

10043E 10045E

M1801 M1801

A1015

10040E

10046E

10044E 10048E

CG-1.F

12.02

6.40D 26.01

F3200

M1803

M3073

A5082

A5075

24"

15"

6.40E

6.40B

12.22

9.09

F3200

M1803

10054E

26.01

26.01

A5108

10053E

M1801

A1015

M1801

10040E

A1015

CG-1.F

9.07

10054E

A5108

F3200

M1803

M3073

10058E

26.01

26.01

A5082

A5075

6.40B

6.40D

6.40A

12.22

6.40E

6.40E

26.31 A1012

A5145

A5107

A5077 26.01

26.01

30" 33" FILLER

30" 33" FILLER

9.09

B6

AI501

D5

AI501

D6

AI501

6.40D

6.40A

6.40B

A5075

A5082 A1012

A5145

A5107

A5077

26.01

12.22

6.40E

26.31

FILLER 33" 30"

FILLER 33" 30"

6.40E

9.09

D6

AI501

D5

AI501

B6

AI501

M1803

F3200

10054N

10013E

A5108

CG-2.F

26.01

9.07

7.81

M1803

F3200

A5108

M9066

CG-2.F

10013E

26.01

9.07

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI401

INTERIOR ELEVATIONS

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

KEYNOTES

KEY VALUE KEYNOTE TEXT

6.40A HPDL BASE CABINET.

6.40B HPDL WALL CABINET WITH SLOPED TOP U.O.N.

6.40D HPDL SINK ENCLOSURE.

6.40E HPDL FINISHED END.

7.81 FLOOR EXPANSION JOINT ASSEMBLY.

9.07 CORNER GUARD, REF. WALL PROTECTION PLAN AND SPECS.

9.09 WALL BASE AS SCHEDULED.

12.02 CUSTOM FURNITURE SYSTEM BY VA.

12.22 SOLID SURFACE COUNTERTOP WITH INTEGRAL LAVATORY.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

26.31 LIGHT FIXTURE, REF. ELECTRICAL.

1/4" = 1'-0" C2

ELEV - HALL C101 MSA REGISTRATION

DESK

1/4" = 1'-0" C1

ELEV - CORR. C1C19 MSA

REGISTRATION DESKS

1/4" = 1'-0" B5

ELEV - C101C EXAM ROOM - E

1/4" = 1'-0"

B4

ELEV - C101C EXAM ROOM - W

1/4" = 1'-0" B1

ELEV - C101D EXAM ROOM - W

1/4" = 1'-0" C6

ELEV - C178 MSA - E

1/4" = 1'-0"

C3

ELEV - C178 MSA - N

1/4" = 1'-0" C4

ELEV - C178 MSA - S

1/4" = 1'-0" B3

ELEV - C101B EXAM ROOM - S

1/4" = 1'-0"

B2

ELEV - C101D EXAM ROOM - E

1/4" = 1'-0" C5

ELEV - C178 MSA - W

1/4" = 1'-0" D5

ELEV - C101F EXAM ROOM - W

1/4" = 1'-0"

D6

ELEV - C101B EXAM ROOM - E

1/4" = 1'-0" D4

ELEV - C101G EXAM ROOM - E

1/4" = 1'-0"

D3

ELEV - C101G EXAM ROOM - W

1/4" = 1'-0" D2

ELEV - C101E EXAM ROOM - E

2.81

10011E

10037E

26.01

9.09B

9.09C

A5200

A5090

7.81

10011E

10037E

7.80

9.09B

9.09C

B2

AI101

2.81

7.81

2.81

9.09B

9.09C

A5090

A5200

2.81

" 9.09B

9.09C

B6

AI501

10013E

10014E

6.40D

12.25

26.31

26.01

26.01

40" 30" 1"

FILLER 36" 33" 18"

6.40E

6.40B

10020.2E

10020E

6.40B

6.40E

10018E

B4

AI501

D4

AI501

D3

AI501

A5075

A5082

B6

AI501

FILLER 24" 30"

12.25

6.40D

10013E

10014E

10021E

24 1/2" 30" 1"

26.01

26.31

6.40E

6.40E

D4

AI501

________ D3

AI501

A5082

A5075

6.40B

C3

AI501

10057E

R4650

9.07 9.07

6.40A

9.09

FILLER

30"

23"

6.40E

CG-1.F CG-1.F

C5

AI501

B5

AI501

FILLER

27" 24" 27"

FILLER

7.81

6.40J

6.40J

6.40A 6.40A

26.31

9.07

26.01

10038E

12.21 26.01

9.09

9.07

FILLER27"24"27"FILLER

7.80

CG-1.F

CG-1.F

12.26

C5

AI501

B5

AI501

C4

AI501

FILLER 36" 36" 36" FILLER

9.07

10008E

6.40J

6.40J

26.31

26.31

26.01

26.01 12.21

6.40A

FILLER 36" 36" 36" FILLER

9.09

6.40A

CG-2.F

A. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS

AT THE PROJECT SITE.

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

REFER TO GI002 AND GI003 SHEETS FOR MOUNTING HEIGHTS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

10015E

10018E

10023E

FILLER 24" 24"

6.40E

6.40B

B3

AI501

1.09

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI402

INTERIOR ELEVATIONS

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

1/4" = 1'-0" D4

ELEV - C180 TOILET - E

1/4" = 1'-0"

D2

ELEV - C180 TOILET - N

1/4" = 1'-0" D3

ELEV - C180 TOILET - S

1/4" = 1'-0"

D5

ELEV - C180 TOILET - W

1/4" = 1'-0" B5

ELEV - C186 URO PRECEDURE ROOM

1/4" = 1'-0"

B4

ELEV - C184 URO PRECEDURE ROOM - W

1/4" = 1'-0" C3

ELEV - HALL C101 EQUIP STORAGE - N

1/4" = 1'-0"

C4

ELEV - HALL C101 EQUIP STORAGE - S

1/4" = 1'-0" C5

ELEV - C1C18 SUPPLY STORAGE

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.09 EXISTING DOOR TO REMAIN. CONTRACTOR RESPONSIBLE FOR

SAFE STORAGE/PROTECTION AND REPLACING OF ANY DAMAGED

COMPONENTS DURING CONSTRUCTION.

2.81 PLUMBING FIXTURES & ALL TLT ACCESSORIES SHALL BE

CAREFULLY REMOVED FOR RE-INSTALLATION AFTER NEW TILE.

CONTRACTOR RESPONSIBLE FOR SAFE STORAGE/PROTECTION

AND REPLACING OF ANY DAMAGED FIXTURES DURING

CONSTRUCTION.

6.40A HPDL BASE CABINET.

6.40B HPDL WALL CABINET WITH SLOPED TOP U.O.N.

6.40D HPDL SINK ENCLOSURE.

6.40E HPDL FINISHED END.

6.40J HPDL WALL CABINET.

7.80 INT. WALL EXPANSION JOINT ASSEMBLY.

7.81 FLOOR EXPANSION JOINT ASSEMBLY.

9.07 CORNER GUARD, REF. WALL PROTECTION PLAN AND SPECS.

9.09 WALL BASE AS SCHEDULED.

9.09B WALL TILE PT-2.

9.09C WALL TILE PT-3.

12.21 SOLID SURFACE COUNTERTOP.

12.25 STAINLESS STEEL COUNTERTOP W/ INTEGRATED SINK, REF.

SPECS.

12.26 DO NOT ATTACH COUNTERTOP TO WALL CLEAT DUE TO

EXPANSION JOINT.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

26.31 LIGHT FIXTURE, REF. ELECTRICAL.

1/4" = 1'-0" B3

ELEV - C184 URO PRECEDURE ROOM - E

A. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS

AT THE PROJECT SITE.

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

REFER TO GI002 AND GI003 SHEETS FOR MOUNTING HEIGHTS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

A5082

A1067

A5075

22.01

9.09B

9.09C

B2

AI101

22.01 22.10A

A1067

A5082

A5109

A5200

A5109A5109

A5090

A5075

26.01

9.09B

9.09C

F2010

9.09C

9.09B

22.10A

F2010

A5200

A5109A5109

A5090

26.01

A5109

9.09C

9.09B

22.01

A1067

A5075

A5082

9.09C

9.09B

22.01

22.10A

A1067

A5082

A5075

A5200

A5109A5109A5109

26.01

A5090

9.09C

9.09B

9.09B

9.09C

A5109

A5200

A5090

A5109A5109

22.10A

26.01

9.09C

9.09B

26.01

22.10A F2010

A5200

A5109

A5090

A5109

A5109

9.09B

9.09C

22.10A

22.01 A5109

A5090

A5200

A5109

A1067

A5109

26.01

26.01

9.09B

9.09C

A5082

A5200

F2010

9.09B

9.09C

22.01

A1067

A5075

A5082

26.01

9.09B

9.09C

10037E

10011E 2.81

26.01

" 9.09B

9.09C

A5090

A5200

2.81

2.81

26.01

9.09C

9.09B

A5200

A5090 10011E

10037E

9.09B

9.09C

B2

AI101

2.81

9.09B

9.09C

1.09

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI403

INTERIOR ELEVATIONS

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.09 EXISTING DOOR TO REMAIN. CONTRACTOR RESPONSIBLE FOR

SAFE STORAGE/PROTECTION AND REPLACING OF ANY DAMAGED

COMPONENTS DURING CONSTRUCTION.

2.81 PLUMBING FIXTURES & ALL TLT ACCESSORIES SHALL BE

CAREFULLY REMOVED FOR RE-INSTALLATION AFTER NEW TILE.

CONTRACTOR RESPONSIBLE FOR SAFE STORAGE/PROTECTION

AND REPLACING OF ANY DAMAGED FIXTURES DURING

CONSTRUCTION.

9.09B WALL TILE PT-2.

9.09C WALL TILE PT-3.

10.44 FIRE ALARM, REF. FIRE ALARM PLAN.

22.01 SINK, REF. PLUMBING.

22.10A ADA TOILET, REF. PLUMBING.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

1/4" = 1'-0" D5

ELEV - D150A TOILET - E

1/4" = 1'-0"

D4

ELEV - D150A TOILET - N

1/4" = 1'-0" D3

ELEV - D150A TOILET - S

1/4" = 1'-0"

D2

ELEV - D150A TOILET - W

1/4" = 1'-0" C5

ELEV - C117A WAITING ROOM TOILET - E

1/4" = 1'-0"

C4

ELEV - C117A WAITING ROOM TOILET - N

1/4" = 1'-0" C3

ELEV - C117A WAITING ROOM TOILET - S

1/4" = 1'-0"

C2

ELEV - C117A WAITING ROOM TOILET - W

1/4" = 1'-0" B5

ELEV - C181 TLT. - E

1/4" = 1'-0" B4

ELEV - C181 TLT. - N

1/4" = 1'-0"

B3

ELEV - C181 TLT. - S

1/4" = 1'-0" B2

ELEV - C181 TLT. - W

1/4" = 1'-0" A5

ELEV - C182 TOILET - E

1/4" = 1'-0"

A4

ELEV - C182 TOILET - N

1/4" = 1'-0" A3

ELEV - C182 TOILET - S

1/4" = 1'-0"

A2

ELEV - C182 TOILET - W

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

VERTICAL BRACING

HPDL ON 3/4" PART

BD SLOPED TOP

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

VALANCE FOR U.C. LIGHTING

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

3/4" SCRIBE

FACE OF SOFFIT

17"

VALANCE FOR U.C. LIGHTING

1" ADJ. SHELVES

SUPPORTED BY 32MM

SYSTEM

MELAMINE FINISH ON

PART. BD., INTERIOR

2x WD. BLOCK'G

AS REQ'D., TYP.

1x WD. BLOCK'G AS

REQ'D., TYP.

1/4" BACK

BASE AS SCHEDULED

PULL, TYP., REF. SPEC.

PULL, TYP., REF. SPEC.

HPDL FINISH ON 3/4"

PART. BD., EXTERIOR

OTHERWISE NOTED IN ELEV.

24" - UNLESS

3"

LOCK WHERE SHOWN ON

ELEVS, REF SPEC, TYP.

R E

F E

L E

V A

T

IO

N S

25"

/4

SOLID SURFACE TOP W/

SQUARE, EASED EDGE

ON 3/4" PLYWD OR MDF &

4" THERMOFORMED

COVED BACK & SIDE

SPLASH W/ TOP EASED

EDGE

1x WD. BLOCK'G AS REQ'D., TYP.

25"

DASHED LINES REPRESENT

OUTLINE OF ADA CLEARANCE

AND OPEN BOTTOM OF

ENCLOSURE

M

IN

A D

A

A D

A

M

IN

ADA

6" MAX

ADA

11" MIN

/2

/2

1"

HPDL FRONT APRON ON 3/4"

PART. BD. W/ 3MM EDGE

BANDING

REMOVABLE APRON, HPDL ON 3/4"

PART. BD. W/ 3MM EDGE BANDING;

CLEAT TO ADJ. SURFACES.

FAUCET, REF. PLUMB'G

SOLID SURFACE TOP W/ NO-DRIP

EDGE ON 3/4" MARINE GRADE

PLYWD OR MDF & 4"

THERMOFORMED COVED BACK &

SIDE SPLASH W/ EASED TOP EDGE

AND SEAMED UNDERMOUNT

INTEGRAL SINK (REF. SPEC) NO

OVERFLOW IN CLINICAL AREAS

/2

/4

ADA

8" MIN

NO BOTTOM PANEL

LAVATORY CARRIER EQUAL TO ZURN

Z1236 (SIZE LENGTH TO C-TOP DEPTH),

REF PLUMB'G SPEC & COORDINATE W/

GENERAL CONTRACTOR; PAINT

EXPOSED SURFACES TO MATCH ADJ

WALL. COORDINATE W/ INSTALLATION

OF MILLWORK; SECURELY FASTEN

CARRIER TO C-TOP SUBSTRATE.

NOTE: PROVIDE FINISHED END

PANELS WHEN SIDES ARE EXPOSED

PLAN VIEW

LAVATORY CARRIER EQUAL TO

ZURN Z1236 (SIZE LENGTH TO C-

TOP DEPTH), REF PLUMB'G SPEC

& COORDINATE W/ GENERAL

CONTRACTOR; PAINT EXPOSED

SURFACES TO MATCH ADJ WALL.

COORDINATE W/ INSTALLATION

OF MILLWORK.

INTEGRAL SEAMED

UNDERMOUNT SINK, NO

OVERFLOW (REF. SPEC)

CORIAN 8252 (BASIS OF DESIGN)

INSTALL ADDITIONAL 3/4"

SUBSTRATE LAYER AT CARRIER

ARMS & SECURELY FASTEN

LINE OF COUNTERTOP AND

APRON BELOW

1" ADJ. SHELVES

SUPPORTED BY 32MM

SYSTEM

MELAMINE FINISH ON

PART. BD., INTERIOR

2x WD. BLOCK'G

AS REQ'D., TYP.

1x WD. BLOCK'G AS

REQ'D., TYP.

1/4" BACK

BASE AS SCHEDULED

PULL, TYP., REF. SPEC.

PULL, TYP., REF. SPEC.

HPDL FINISH ON 3/4"

PART. BD., EXTERIOR

OTHERWISE NOTED IN ELEV.

24" - UNLESS

3"

LOCK WHERE SHOWN ON

ELEVS, REF SPEC, TYP.

R E

F E

L E

V A

T

IO

N S

25"

/4

SOLID SURFACE TOP W/

NO-DRIP EDGE ON 3/4"

MARINE GRADE PLYWD

OR MDF & 4"

THERMOFORMED COVED

BACK & SIDE SPLASH W/

TOP EASED EDGE

/2

1" ADJ. SHELVES

SUPPORTED BY 32MM

SYSTEM

MELAMINE FINISH ON

PART. BD., INTERIOR

2x WD. BLOCK'G

AS REQ'D., TYP.

1x WD. BLOCK'G AS

REQ'D., TYP.

1/4" BACK

BASE AS SCHEDULED

PULL, TYP., REF. SPEC.

PULL, TYP., REF. SPEC.

HPDL FINISH ON 3/4"

PART. BD., EXTERIOR

30"

3"

LOCK WHERE SHOWN ON

ELEVS, REF SPEC, TYP.

R E

F E

L E

V A

T

IO

N S

31"

/4

SOLID SURFACE TOP W/

SQUARE, EASED EDGE

ON 3/4" PLYWD OR MDF &

4" THERMOFORMED

COVED BACK & SIDE

SPLASH W/ TOP EASED

EDGE

INCLUDE 32MM SYSTEM

FOR FUTURE FLEXIBILITY

HPDL FINISH ON

PART. BD., INTERIOR

2x WD. BLOCK'G

AS REQ'D., TYP.

1x WD. BLOCK'G AS

REQ'D., TYP.

1/4" BACK

BASE AS SCHEDULED4

R E

F E

L E

V A

T

IO

N S

25"

/4

SOLID SURFACE TOP W/

SQUARE, EASED EDGE

ON 3/4" PLYWD OR MDF &

4" THERMOFORMED

COVED BACK & SIDE

SPLASH W/ TOP EASED

EDGE

3MM EDGEBANDING

OTHERWISE NOTED IN ELEV.

24" UNLESS

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

VERTICAL BRACING

HPDL ON 3/4" PART

BD SLOPED TOP

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

21"

HPDL FINISH ON

PART. BD., INTERIOR

3MM EDGEBANDING

3MM EDGEBANDING

16GA 316 STAINLESS STEEL

TOP W/ BOX MARINE EDGE;

REF. SPECS

BASE AS

SCHEDULED

1X WD. BLOCK'G AS REQ'D. TYP.

/2

R E

F E

L E

V A

T

IO

N S

1"

/4

25"

STAINLESS STEEL REINFORCING

HAT CHANNELS, MARINE GARDE

PLYWOOD BACKING WITH WHITE

LAMINATE FACING

16GA 316 STAINLESS STEEL

TOP W/ BOX MARINE EDGE;

REF. SPECS

BASE AS SCHEDULED

LAVATORY CARRIER EQUAL TO

ZURN Z1236 (SIZE LENGTH TO C-

TOP DEPTH), REF PLUMB'G SPEC

& COORDINATE W/ GENERAL

CONTRACTOR; PAINT EXPOSED

SURFACES TO MATCH ADJ WALL.

COORDINATE W/ INSTALLATION

OF MILLWORK; SECURELY

FASTEN CARRIER TO C-TOP

SUBSTRATE.

M

IN

A D

A

/2

/4

A D

A

M

IN

ADA

6" MAX

ADA

11" MIN

ADA

8" MIN

1"

25"

1"

/4

/2

HPDL FRONT APRON ON 3/4"

PART. BD. W/ 3MM EDGE

BANDING

14" X 16" X 5 1/2" INTEGRAL

STAINLESS STEEL SINK

REMOVABLE APRON, HPDL ON 3/4"

PART. BD. W/ 3MM EDGE BANDING;

CLEAT TO ADJ. SURFACES.

1x WD. BLOCK'G AS REQ'D., TYP.

NO BTTOM PANEL

FAUCET, REF. PLUMB'G

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

VERTICAL BRACING

HPDL ON 3/4" PART

BD SLOPED TOP

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI501

MILLWORK SECTION DETAILS

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

1" = 1'-0" B6

SECTION - TYPICAL WALL CABINET

1" = 1'-0"

B5

SECTION - WALL CABINET AT SOFFIT

1" = 1'-0" C5

SECTION - TYPICAL BASE CABINET

1" = 1'-0" D6

SECTION - TYPICAL SINK ENCLOSURE

1" = 1'-0"

D5

SECTION - TYPICAL BASE CABINET W/

NO DRIP EDGE

1" = 1'-0" C3

SECTION - DEEP BASE CABINET

1" = 1'-0"

C4

SECTION - OPEN BASE CABINET

1" = 1'-0" B4

SECTION - WALL CABINET WITH OPEN

BOTTOM SHELVES

1" = 1'-0" D4

SECTION - OPEN STAINLESS STEEL

COUNTERTOP

1" = 1'-0" D3

SECTION - TYPICAL STAINLESS STEEL

SINK ENCLOSURE

1" = 1'-0" B3

SECTION - WALL CABINET, NO UCL

FEC

A:

G:

DOOR MOUNT

9"

Authorized Personnel Only

10"

BACKGROUND COLOR:

CSS OFF-WHITE,

BOLD COPY COLOR:

BLACK

SIGN LEGEND

C:

Crash Cart

WALL MOUNT

9"

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: FIRE RED,

GRAPHIC & COPY

COLOR: WHITE

BABY CHANGING STATION

LOCATED IN MAIN CORRIDOR

IN RESTROOM ####

E:

FLAG WALL MOUNT

9"

Z:

DOOR MOUNT

9"

BIOHAZARD

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: ORANGE,

GRAPHIC & COPY

COLOR: BLACK

K:

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND &

MARGIN COLOR:

METALLIC SILVER,

GRAPHIC & BOLD

COPY COLOR: BLACK

9"

WALL MOUNTED

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

3/8" RADIUS

CORNERS

RESTROOM

WALL MOUNT

9"

1" X 1/32" ADA TACTILE

BOLD COPY & GRADE 2

BRAILLE

B:

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

RESTROOM

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

RAISED SYMBOL

9"

ROOM #

R.1:

WALL OR DOOR MOUNT

ROOM NAME

1" X 1/32" ADA TACTILE

BOLD NUMERALS AND

GRADE 2 BRAILLE,

COPY COLOR: BLACK

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: METALLIC

SILVER

UPPER/LOWER PANELS -

MAGNETICALLY

REMOVEABLE F-UNIT

WALL MOUNT

R:

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED

BACKGROUND COLOR -

METALLIC SILVER

5-3/16" X 9" CLEAR

ACETATE INSERT

BOLD BLACK COPY

GRAPHIC WATERMARK

"WAVING US FLAG" ON

1/16" CLEAR ACRYLIC

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

9"

ROOM #

1" X 1/32" ADA TACTILE

BOLD NUMERALS AND

GRADE 2 BRAILLE,

COPY COLOR: BLACK

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: METALLIC

SILVER

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

WALL / DOOR MOUNT

D:

FLAG WALL MOUNT

9"

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

3/8" RADIUS

CORNERS

CHECK-OUT

TEXT ON BOTH SIDES

OF SIGN

1" X 1/32" BOLD COPY

F:

Fire Extinguisher

9"

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: FIRE RED,

GRAPHIC & COPY

COLOR: WHITE

1" X 1/32" BOLD COPY

WALL MOUNT

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

CLEAR ACRYLIC

SLEEVE TO ACCEPT

8 1/2" X 11" PAPER

PATIENT INSTRUCTIONS

SIGNAGE NOTES

1. SIGN LOCATION ID DISTINGUISHED WITH SIGN TAG NUMBER EQUAL TO THE ROOM NUMBER AND SIGN TYPE (EX: A313-P)

2. REFERENCE GRAPHICAL SIGN ILLUSTRATIONS FOR SIGNAGE REQUIRING ROOM NUMBERS.

3. VA, ARCHITECT, CONTRACTOR, AND SIGNAGE SUPPLIER TO MEET AND AGREE ON SIGNAGE COPY/MESSAGE/TEXT PRIOR TO SIGNAGE SUBMITTAL

DOCUMENTS FOR APPROVAL.

4. SIGNAGE SUBMITTAL TO INCLUDE VISUAL GRAPHIC OF EACH INDIVIDUAL SIGN IN PROJECT.

5. WALL MOUNTED SIGNS TO BE MECHANICALLY FASTENED TO WALL.

6. SIGNAGE DESIGN AND MATERIALS TO MATCH EXISTING HSTVA SIGNAGE STANDARDS, REF SPEC.

7. ALL SIGNAGE TO BE IN COMPLIANCE WITH ADA & ABA ACCESSIBILITY STANDARDS FOR FEDERAL FACILITIES.

8. SQUARE SATIN ANODIZED ALUMINUM FRAME.

9. SIGN COMPANY TO PURCHASE ALL GRAPHIC IMAGES FOR THE HOSPITAL. SIGN COMPANY RESPONSIBLE FOR MODIFYING BACKGROUND ON IMAGES.

10. SIGN COMPANY TO PROVIDE OWNER WITH SOFTWARE, PRINTER, MATERIALS & INSTRUCTIONAL CLASS ON HOW TO UPDATE CHANGEABLE SIGNS.

11. SIGN COMPANY TO PROVIDE DISC OF TEMPLATE LAYOUT DRAWINGS, COLOR, AND TYPOGRAPHY SPECS FOR ALL CHANGEABLE SIGNS INCLUDING DIRECTORY, DIRECTIONALS, AND OVERHEADS.

12. SIGNAGE INSTALLER TO COORDINATE LOCATIONS OF CEILING HUNG SIGNS WITH FIRE PROTECTION SPRINKLER HEADS ACCORDING TO NFPA REGULATIONS.

13. SIGNAGE MOUNTED TO GLASS SHALL HAVE BLANK FACE PLATE ON OPPOSITE SIDE TO CONCEAL ATTACHMENT METHOD.

PROVIDER

SWAMP

C187

STOR.

C185

URO

PROCEDURE

C186

TLT.

C180

NAVIGATOR

C183

EXAM #6

C101F

EXAM #4

C101D

EXAM #2

C101B

CLEAN

UTILITY

C179

MSA

C178

CORR.

C1D5

CORR.

C1C19

TLT.

C177A

EXAM #1

C101AEXAM #3

C101C

EXAM #5

C101E

TLT.

C181

NURSE

ALCOVE

EXAM #7

C101G

TLT.

C182

EQUIP.

HALL

C101

HALL

C101HALL

C101CORR.

C1C18

CORR.

C1C18

CORR.

C1C18

TLT.

C189

URO

PROCEDURE

C184

SOILED

C188

S U

P P

L

IE

S

NAVIGATOR

SWAMP

D150

TLT.

D150A

WAITING

C177

R R

A

R

R

R R R R

K

R

R R RR R R

R

R

R

R.1

K

B

B

A

E B

R

B

B

R

B

E L E

C

D

EQUIP.

ALCOVE

R.1

A

Z

C

O

O.V

D

F

E

O.V

G

G

D151

D100A

#6

C1D9C1D5C1C9C1C9

C1C2

C192

C191

C1C1

C1D1

C105

C103 C102

OVERHEAD SIGN LEGEND

6' - 0"

TEXT VERIFIED BY VA

SIZES VARY FOR EACH TYPE

C1D5-O EAST FACING SIDE:

6' - 0"

TEXT VERIFIED BY VA

SIZES VARY FOR EACH TYPE

C1D5-O WEST FACING SIDE:

C1C19-O.V:

CHECK-IN VINYL LETTERS APPLIED TO SOFFIT

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

AI601

SIGNAGE PLAN & SCHEDULE - 1ST

FLOOR

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

JSJIEP

N

0' 2'-0" 4'-0" 8'-0"1/4" = 1'-0" D2

SIGNAGE PLAN - 1ST FLOOR

SIGNAGE SCHEDULE

ARCH. ROOM

NUMBER ARCH. ROOM NAME SIGN TYPE SIGN TYPE DESCRIPTION MOUNTING SURFACE SIGN COPY SINGLE-SIDED/SIDE A SIGN COPY SIDE B NOTES

CRASH CART C LOCATOR SIGN WALL CRASH CART

C1C18 CORR. A AUTHORIZED ONLY DOOR AUTHORIZED PERSONNEL ONLY

C1C18 CORR. R ROOM SIGN WALL PROCEDURE

C1C19 CORR. F FIRE EXTINGUISHER WALL FIRE EXTINGUISHER

C1D5 CORR. G PAPER SLEEVE WALL - REFERENCE LEGEND FOR COPY

C1D5 CORR. O OVERHEAD WAYFINDING OVERHEAD UROLOGY CLINIC UROLOGY CLINIC REF. SIGN DETAILS FOR COPY ON BOTH SIDES

C1D5 CORR. R ROOM SIGN WALL UROLOGY CLINIC

C101A EXAM #1 R ROOM SIGN WALL EXAM #1

C101B EXAM #2 R ROOM SIGN WALL EXAM #2

C101C EXAM #3 R ROOM SIGN WALL EXAM #3

C101D EXAM #4 R ROOM SIGN WALL EXAM #4

C101E EXAM #5 R ROOM SIGN WALL EXAM #5

C101F EXAM #6 R ROOM SIGN WALL EXAM #6

C101G EXAM #7 R ROOM SIGN WALL EXAM #7

C177A TLT. B RESTROOM SIGNAGE WALL RESTROOM

C177A TLT. G PAPER SLEEVE DOOR - REFERENCE LEGEND FOR COPY

C177A TLT. K BABY CHANGING WALL REFERENCE LEGEND FOR COPY

C178 MSA D ROOM SIGN FLAG/WALL CHECK-OUT

C178 MSA O.V APPLIED LETTERING SOFFIT CHECK-IN #1 6" VINYL LETTERS ON SOFFIT

C178 MSA O.V APPLIED LETTERING SOFFIT CHECK-IN #2 6" VINYL LETTERS ON SOFFIT

C178 MSA R ROOM SIGN WALL MSA

C179 CLEAN UTILITY R ROOM SIGN WALL CLEAN UTILITY

C180 TLT. B RESTROOM SIGNAGE WALL RESTROOM

C181 TLT. B RESTROOM SIGNAGE WALL RESTROOM

C181 TLT. E RESTROOM SIGNAGE FLAG/WALL RESTROOM RESTROOM

C182 TLT. B RESTROOM SIGNAGE WALL RESTROOM

C183 NAVIGATOR R ROOM SIGN WALL NAVIGATOR

C184 URO PROCEDURE R ROOM SIGN WALL PROCEDURE #1

C184 URO PROCEDURE R ROOM SIGN WALL PROCEDURE #1

C185 STORAGE R ROOM SIGN WALL EQUIPMENT STORAGE

C186 URO PROCEDURE A AUTHORIZED ONLY DOOR AUTHORIZED PERSONNEL ONLY

SIGNAGE SCHEDULE

ARCH. ROOM

NUMBER ARCH. ROOM NAME SIGN TYPE SIGN TYPE DESCRIPTION MOUNTING SURFACE SIGN COPY SINGLE-SIDED/SIDE A SIGN COPY SIDE B NOTES

C186 URO PROCEDURE R ROOM SIGN WALL PROCEDURE #2

C186 URO PROCEDURE R ROOM SIGN WALL PROCEDURE #2

C186 URO PROCEDURE R.1 SMALL ROOM SIGN WALL URO PROCEDURE

C187 PROVIDER SWAMP R ROOM SIGN WALL PROVIDER SWAMP

C188 SOILED R ROOM SIGN WALL SOILED

C188 BIOHAZARD Z WARNING SIGN DOOR BIOHAZARD

C189 TLT. B RESTROOM SIGNAGE WALL RESTROOM

D150 NAVIGATOR SWAMP A AUTHORIZED ONLY DOOR AUTHORIZED PERSONNEL ONLY

D150 NAVIGATOR SWAMP R ROOM SIGN WALL NAVIGATOR SWAMP

D150A TLT. B RESTROOM SIGNAGE WALL RESTROOM

D150A TLT. E RESTROOM SIGNAGE FLAG/WALL RESTROOM RESTROOM

D150A TLT. K BABY CHANGING WALL REFERENCE LEGEND FOR COPY

D194 ELEC R.1 SMALL ROOM SIGN DOOR ELECTRICAL

APPLY TO ALL FIRE SUPPRESSION SHEETS

FIRE PROTECTION WORK SHALL INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING:

A. ENTIRE PROJECT REMODEL AREA OF THE FACILITY IS CURRENTLY PROTECTED WITH AN AUTOMATIC FIRE

SPRINKLER SYSTEM. REVISE SYSTEM PER CONTRACT DRAWINGS AND SPECIFICATIONS.

B. UPON COMPLETION OF THIS PROJECT, THE FIRE SPRINKLER SYSTEM SHALL REMAIN A FULL, COMPLETE, AND OPERABLE SYSTEM THAT IS IN COMPLIANCE WITH THE REQUIREMENTS OF THE DEPARTMENT OF VETERANS ADMINISTRATION, INCLUDING ALL PIPING AND ALL VALVES, ETC. PROVIDE NEW VALVES AND

FIRE PROTECTION EQUIPMENT WHERE NOTED ON THE PLANS.

C. EXISTING COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM IS SERVED BY AN ELECTRIC HORIZONTAL SPLIT CASE FIRE PUMP RATED FOR 750 GPM AT 83 PSI, 3560 RPM. PRESSURE AT 150 PER CAPACITY IS 57 PSI. B.H.P. IS 51.5 WITH ONE STAGE. MAXIMUM BHP IS 55.5. MAXIMUM SUCTION IS 223 PSI.

D. ALL AREAS OF THE BUILDING INDICATED SHALL BE SPRINKLERED ACCORDING TO THE LATEST EDITION OF APPLICABLE NFPA STANDARDS, SPECIFICALLY NFPA 13 AND 25. ENTIRE SYSTEM SHALL BE INSTALLED PER THE REQUIREMENTS OF THE DEPARTMENT OF VETERAN'S AFFAIRS (VA). THIS FACILITY IS SERVICED BY THE COLUMBIA, MISSOURI, FIRE DEPARTMENT. FIREPROOF ALL WALL AND FLOOR PENETRATIONS.

E. SEISMIC BRACING WILL BE REQUIRED IN ACCORDANCE WITH NFPA 13 DESIGN GUIDELINES. BUILDING IS

IN SEISMIC DESIGN CATEGORY 'C'.

F. COORDINATE CONSTRUCTION TO KEEP EXISTING SPRINKLER SYSTEM IN SERVICE AS LONG AS POSSIBLE.

COORDINATE WITH INTERIM LIFE SAFETY MEASURES (ISLM) IN SPEC SECTION GENERAL REQUIREMENTS.

PROVIDE FIRE WATCH IN ACCORDANCE WITH CURRENT FIRE CODES FOR AREAS OF THE BUILDING THAT ARE OUT OF SERVICE. PROVIDE UPRIGHT STYLE SPRINKLERS TO PROTECT THE PROJECT AREA DURING

CONSTRUCTION.

G. DESIGN SHALL BE BASED ON HYDRAULIC CALCULATIONS PER NFPA 13 AS MODIFIED BY THE DIVISION 21 SPECIFICATION, WITH SHOP DRAWINGS PREPARED ACCORDING TO THE REQUIREMENTS OF THE VA.

CALCULATIONS SHALL BEGIN WITH THE REMOTE SPRINKLER AND END AT THE CONNECTION TO THE

EXISTING DOMESTIC WATER SUPPLY. FIELD VERIFY EXISTING CONDITIONS.

H. COORDINATE ALL FIRE ALARM CONNECTION REQUIREMENTS WITH THE FIRE ALARM INSTALLING

CONTRACTOR.

I. DRAWINGS ARE DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF WORK AND GENERAL

ARRANGEMENT OF THE SYSTEM. COORDINATE THE SPRINKLER SYSTEM LAYOUT WITH ALL

ARCHITECTURAL, STRUCTURAL, HVAC, PLUMBING AND ELECTRICAL COMPONENTS. PROVIDE OFFSETS

AS NECESSARY TO AVOID CONFLICTS.

J. DOCUMENTS PROVIDE THE GENERAL AREAS TO BE PROTECTED/RENOVATED AS PART OF THIS PROJECT AND THE GUIDELINES TO BE FOLLOWED BY THE SPRINKLER INSTALLING CONTRACTOR WHEN DESIGNING THE ACTUAL SPRINKLER LAYOUT. THE EXACT NUMBER, TYPE, COVERAGE, ETC., OF SPRINKLERS SHALL BE DETERMINED BY THE CONTRACTOR AND SHALL BE SUBJECT TO APPROVAL BY ALL AUTHORITIES

HAVING JURISDICTION - SPECIFICALLY, THE DEPARTMENT OF VETERAN'S AFFAIRS.

K. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES AND HEIGHTS, AND LOCATIONS OF EXPOSED STRUCTURE. COORDINATE ALL SPRINKLER LOCATIONS IN AS AESTHETIC SPACING AS POSSIBLE.

CONTRACTOR SHALL ALSO CONFIRM EXISTING CEILING LOCATIONS THAT ARE TO REMAIN. REVIEW

SPRINKLER PLANS WITH ARCHITECT/ENGINEER BEFORE INSTALLATION.

L. ALL PIPING AND SPRINKLERS IN EXPOSED AREAS SHALL BE CLOSELY COORDINATED WITH

ARCHITECTURAL AND STRUCTURAL FEATURES, DUCTWORK AND LIGHTS. EXPOSED SPRINKLERS SHALL BE UPRIGHT UNLESS SPECIFICALLY SHOWN OTHERWISE ON THE DRAWINGS. PROVIDE ADDITIONAL SPRINKLERS AS NECESSARY TO OVERCOME ANY OBSTRUCTIONS TO THE SPRINKLER SPRAY PATTERNS

AS REQUIRED BY NFPA 13.

M. ALL SPRINKLERS IN GYP. BOARD AND LAY-IN CEILINGS SHALL BE SEMI-RECESSED PENDENT TYPE WITH FACTORY APPLIED WHITE FINISH, UNLESS NOTED OTHERWISE. ALL SPRINKLERS IN SOFFITS SHALL BE SEMI-RECESSED SIDEWALLS WITH FLAT FACE AND FACTORY APPLIED WITH WHITE FINISH, UNLESS NOTED OTHERWISE. PER VA DESIGN GUIDELINES, ALL SPRINKLERS SHALL BE UL LISTED AND FM APPROVED FOR QUICK RESPONSE, EXCEPT WHERE SPECIFICALLY NOTED DIFFERENTLY ON THE PLANS.

N. PROVIDE AUXILIARY DRAINS FOR ALL LOW SPOTS, TYPICAL. WHERE LESS THAN 5 GALLONS OF WATER IS TRAPPED, PER NFPA 13 DESIGN GUIDELINES, A CAPPED MAIN MAY BE PROVIDED IN LIEU OF AN AUXILIARY

DRAIN VALVE.

O. EXISTING SPRINKLER SYSTEM PROVIDED FROM AVAILABLE SHOP DRAWINGS AND SITE OBSERVATION THAT DID NOT NECESSARILY INCLUDE FULL ABOVE CEILING OBSERVATION. CONTRACTORS SHALL FIELD

VERIFY EXISTING CONDITIONS PRIOR TO CREATION OF SHOP DRAWING SUBMITTAL.

P. SPRINKLERS SHOWN ADJACENT TO AIR OUTLETS/INLETS AND LIGHT FIXTURES SHALL BE LOCATED 6" MINIMUM FROM BOTH. ALL SPRINKLERS IN LAY-IN CEILINGS SHALL BE INSTALLED WITHIN 3" OF THE CENTER OF CEILING TILE. NOTIFY ARCHITECT/ENGINEER OF CONFLICTS. SHOW ALL LIGHTS, HVAC DIFFUSERS, AND ALL HEAT PRODUCING PIECES OF EQUIPMENT (I.E. CABINET UNIT HEATERS) ON

SPRINKLER LAYOUT DRAWINGS.

Q. PROVIDE HIGHER TEMPERATURE RATED SPRINKLERS IN ACCORDANCE WITH NFPA 13 DESIGN

GUIDELINES FOR NY SPRINKLER INSTALLED WITHIN 30 INCHES OF A SUPPLY AIR DIFFUSER OR HEAT

PRODUCING EQUIPMENT.

R. SPRINKLER CONTRACTOR TO FIELD VERIFY EXISTING SPRINKLER SYSTEM FOR AREAS OF THE BUILDING WHERE THE SYSTEM IS BEING REMOVED, MODIFIED, OR REMODELED PRIOR TO CREATION OF THEIR

SHOP DRAWING SUBMITTAL. VERIFY PIPE SIZES AND LOCATIONS.

S. SEE DIVISION 21 SPECIFICATION SECTIONS FOR ADDITIONAL REQUIREMENTS.

T. SPRINKLER CONTRACTOR TO DETERMINE AVAILABLE WATER PRESSURES AND FLOW FROM LOCAL WATER DEPARTMENT. CONTRACTOR SHALL SUBMIT HYDRANT FLOW TEST DATA THAT IS NOT MORE THAN ONE YEAR OLDER THAN THE DATE OF SHOP DRAWING SUBMITTAL. CONTRACTOR SHALL ALSO USE

CURRENT FIRE PUMP TESTING DATA INCLUDED IN PROJECT SPECIFICATIONS.

U. SPRINKLER CONTRACTOR SHALL COORDINATE ALL CEILING HEIGHTS WITH GENERAL CONTRACTOR BEFORE MAKING FINAL PIPE DROPS TO SPRINKLERS. A COST EXTRA IS NOT ACCEPTED IF CEILING HEIGHTS CHANGE AFTER DROPS HAVE BEEN INSTALLED AND COORDINATION DID NOT OCCUR PRIOR TO

INSTALLATION.

V. COORDINATE INSTALLATION OF ALL PIPING SYSTEMS WITH GENERAL CONTRACTOR TO PREVENT PIPING FREEZEUPS. NOTIFY ARCHITECT AND ENGINEER OF AREAS FOR POTENTIAL FREEZEUP CONCERNS.

W. ALL EXPOSED PIPING IN ALL PUBLIC AND STORAGE SPACES SHALL BE PAINTED. SPRINKLER INSTALLER

SHALL BE RESPONSIBLE FOR THE PROTECTION OF THE SPRINKLERS DURING THE PAINTING OF ALL

EXPOSED PIPING. SPRINKLER CONTRACTOR SHALL INSPECT ALL SPRINKLERS UPON COMPLETION OF

PAINTING TO VERIFY NO OVERSPRAY. SPRINKLER CONTRACTOR SHALL CLEAN ANY OVER-SPRAY OR

REPLACE AFFECTED SPRINKLERS WHERE OVER-SPRAY CANNOT BE REMOVED. PAINT COLOR TO MATCH CEILING FINISH IN AREA OF PIPE UNLESS NOTED OTHERWISE ON DRAWING. PROVIDE PIPE MATERIAL

ACCEPTABLE FOR PAINTING.

X. APPLICABLE UL CONSTRUCTION DETAILS SHALL BE USED WHERE RATED ASSEMBLIES ARE PENETRATED

BY SPRINKLER PIPING SYSTEM.

Y. ALL HOLES FOR PIPING AND CONDUIT SHALL BE DRILLED OR CORE DRILLED. NO BREAKING OF

CONCRETE OR C.M.U. SHALL BE PERMITTED.

Z. SEAL ALL WALL PENETRATIONS AND PROVIDE A WALL PLATE ON EACH SIDE OF THE PIPE PENETRATION.

WHERE EXPOSED PIPING IS IN A PUBLIC SPACE, THE WALL PLATE SHALL MATCH THE WALL FINISH COLOR.

PIPE OPENINGS THROUGH FIRE RATED WALLS SHALL BE CAULKED WITH A FIRE RETARDANT

INTUMESCENT MATERIAL. SEE SPECIFICATIONS.

AA. PROVIDE SPRINKLER PROTECTION BELOW ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND

HVAC DUCTS 4'-0" AND GREATER, AS REQUIRED BY THE LATEST EDITION OF NFPA 13.

BB. COORDINATE WITH PLUMBING, MECHANICAL HVAC, AND ELECTRICAL WORK. DO NOT INSTALL SPRINKLER PIPING BELOW SUSPENDED EQUIPMENT, EXCEPT AS REQUIRED TO BE IN ACCORDANCE WITH NFPA 13 DESIGN GUIDELINES FOR EXPOSED CONSTRUCTION. DO NOT INSTALL SPRINKLER PIPING WITHIN

CLEARANCE SPACES FOR MECHANICAL OR ELECTRICAL EQUIPMENT.

CC. ROUTE SPRINKLER PIPING AS HIGH AS POSSIBLE THROUGHOUT STRUCTURE, UNLESS SPECIFICALLY

NOTED OTHERWISE ON DRAWINGS.

DD. SUPPORT ALL PIPING FROM STRUCTURE. SEE DETAILS 1 AND 2 ON THIS SHEET.

EE. ALL MATERIALS FOR THIS PROJECT SHALL COMPLY WITH THE "BUY AMERICAN" REQUIREMENTS

OUTLINED IN THE CONTRACT SPECIFICATIONS.

FF. CEILING GRID PROVIDED FOR COORDINATION PURPOSES. SEE ARCHITECTURAL PLANS FOR FINAL GRID AND CEILING HEIGHTS. SEE MECHANICAL AND ELECTRICAL PLANS FOR SYMBOL IDENTIFICATION.

GG. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING, PAINTING, REPAIRING OR REPLACEMENT OF ALL WALLS, CEILINGS, OR OTHER BUILDING ELEMENTS WHICH ARE DISTURBED AS PART OF THE

DEMOLITION OR INSTALLATION OF FIRE SPRINKLER WORK.

HH. REMOVE AND RE-INSTALL LAY-IN CEILINGS AS NECESSARY FOR INSTALLATION OF PIPING AND SPRINKLERS. WHERE CEILING MATERIALS ARE DAMAGED DURING INSTALLATION OF SPRINKLER PIPE OR SPRINKLER HEADS, NEW MATERIALS SHALL BE INSTALLED. NEW MATERIALS SHALL MATCH EXISTING

MATERIALS.

II. SPRINKLER CONTRACTOR SHALL REVIEW AREAS WHERE NEW CEILINGS OCCUR. PROVIDE SPRINKLING

OF THE AREA ABOVE THESE CEILINGS WHERE REQUIRED BY REFERENCED CODES.

JJ. ALL NEW SPRINKLER DROPS SHALL BE INSTALLED ON FLEXIBLE DROPS.

KK. ROUTE SPRINKLER PIPING AROUND ELECTRICAL, DATA, IT, COMM AND ALL OTHER ROOMS DESIGNATED TO ELECTRICAL COMPONENTS AND/OR PANELS. PROTECT THESE AREAS WITH SIDEWALL SPRINKLERS

WHEN POSSIBLE WITHOUT ROUTING PIPE EXPOSED IN PUBLIC AREAS.

GENERAL FIRE SUPPRESSION NOTES

FIRE SUPPRESSION SYMBOLS

LEGEND

(AS APPLICABLE)

SPRINKLER MAIN (X DENOTES SPRINKLER ZONE NUMBER IF APPLICABLE)

FIRE DEPARTMENT CONNECTION PIPE

FIRE TEST HEADER PIPE

DESCRIPTIONSYMBOL

F FIRE MAIN PIPE

FTH

FDC

SM-X

POST INDICATOR VALVE

PRESSURE GAUGE

EXPOSED PENDANT SPRINKLER

SEMI-RECESSED PENDANT SPRINKLER

CONCEALED PENDANT SPRINKLER

UPRIGHT SPRINKLER

PIV

POINT OF DISCONNECT

NEW CONNECTION POINT

EXPOSED SIDEWALL SPRINKLER

DRY CONCEALED PENDANT SPRINKLER

SEMI-RECESSED SIDEWALL SPRINKLER

CONCEALED SIDEWALL SPRINKLER

DRY EXPOSED PENDANT SPRINKLER

DRY SEMI-RECESSED PENDANT SPRINKLER

DC

D

DR

R

C

R

C

NOTE: ITEMS SHOWN IN HALFTONE ARE EXISTING TO REMAIN.

ITEMS SHOWN IN DARK DASHED LINE ARE TO BE DEMOLISHED.

ITEMS SHOWN IN DARK BOLD SOLID LINE ARE NEW TO BE PROVIDED.

PIPE SIZE INDICATED ON PLANS.

1. ALL EXISTING ITEMS AND ASSOCIATED PIPING, ACCESSORIES, SUPPORTS, AND HANGARS

INDICATED BY BOLD, DASHED, HEAVY LINES OR IDENTIFIED BY NOTES, SHALL BE

COMPLETELY REMOVED. PRIOR TO PROPER DISPOSAL OF REMOVED ITEMS, OWNER SHALL

HAVE FIRST RIGHT OF REFUSAL.

2. KEEP EXISTING SPRINKLER SYSTEM IN SERVICE AS MUCH AS IS FEASIBLE. PROVIDE FIRE

WATCH IF OUTAGE IS TO BE OVER 4 HOURS IN DURATION.

3. CONTRACTOR TO NOTIFY COR (ISLM FOR LIFE SAFETY) OF OUTAGE REQUEST 10 DAYS

PRIOR TO MINOR OUTAGES AND 15 DAYS PRIOR TO MAJOR OUTAGES.

4. DRAWINGS INDICATE APPROXIMATE ROUTING OF PIPING, DUCTWORK AND MAJOR

COMPONENTS AND DO NOT INCLUDE ALL OFFSETS, FITTINGS, VALVES, ETC. CONTRACTOR

SHALL FIELD VERIFY EXACT SIZE AND ROUTING PRIOR TO REMOVAL OR RELOCATION.

CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF MISCELLANEOUS FIRE

SUPPRESSION ITEMS LOCATED ON OR IN ANY WALLS TO BE REMOVED.

5. ALL OPENINGS THROUGH WALLS AND FLOOR SLABS NOT BEING REUSED SHALL BE

PATCHED WITH LIKE MATERIALS AND PAINTED TO MATCH EXISTING.

FIRE SUPPRESSION DEMOLITION NOTES:

BEAM CLAMP

ZINC COATED

ALL THREADED ROD

HANGER RING

S T

E E

L

HANGER NOTES

1"-1 1/4" EVERY 12'-0"

1 1/2"-6" EVERY 15'-0"

3/8" ROD 1"-4", 1/2" ROD 6"

GENERAL NOTES:

1. HANG ALL ARMOVERS LONGER THAN 2'-0".

2. ALL HANGERS PER NFPA 13.

3. THERE SHALL BE NOT LESS THAN ONE HANGER FOR

EACH SECTION OF PIPE.

4. ALL RODS SHALL BE ZINC COATED UNLESS OTHERWISE NOTED.

RESTRAINING

STRAP

S T

E E

L

TYPICAL LATERAL SWAY BRACE ASSEMBLY TYPICAL LONGITUDINAL SWAY BRACE ASSEMBLY

TWO TYPICAL FOUR-WAY SWAY BRACE ASSEMBLIES

1. PROVIDE STRUCTURAL CALCULATIONS IN ACCORDANCE WITH NFPA 13 INSTALLATION GUIDELINES FOR INSTALLATION IN A SEISMIC ZONE. SEE

STRUCTURAL PLANS AND SPECIFICATIONS FOR RISK AREA DETAILS.

2. ANY SEISMIC BRACING NOTED WITHIN NFPA 13 IS PERMITTED. DETAILS ABOVE ARE TYPICAL METHODS APPROVED FOR USE.

NOTES:

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:232047

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

on e e ig ht h on e q ua rt er i nc h th re e e ig o ne f oo t on e h al f ne f oo t th re e q ua rt er s on e in ch on e h al f in ch es o ne f oo t th re e in ne f oo t

CONSULTANTS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STREET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

ARCHITECT OF RECORD:

12700 WEST DODGE ROAD

OMAHA, NEBRASKA 68154

402.330.5900

2550 UNIVERSITY AVE. W., SUITE 423-S

ST. PAUL, MINNESOTA 55114

651.251.7570

330 N MEAD ST, SUITE 100

WICHITA, KANSAS 67202

316.262.2500

03/22/2024

FG101

FIRE SUPPRESSION SYMBOLS

LEGEND, GENERAL NOTES, AND

DETAILS

RENOVATE & EXPAND

UROLOGY CLINIC

800 HOSPITAL DRIVE COLUMBIA, MO 65201

03-22-2024

589A4-23-050

FINAL BID DOCUMENTS

MKMDGK

NOTICE:

DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND

CLEARANCES FROM ARCHITECTURAL, STRUCTURAL,

SHOP AND OTHER APPROPRIATE DRAWINGS OR AT

SITE. LAY OUT AND COORDINATE ALL WORK PRIOR TO

INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR

OPERATION, MAINTENANCE, AND CODES.

VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT

FABRICATE PRIOR TO VERIFICATION OF CLEARANCES

FOR ALL TRADES. THIS NOTICE APPLIES TO ALL

FIRE SUPPRESSION PLANS.

NOT TO SCALE

1 HANGER DETAILS WITH SEISMIC RESTRAINTS

SCALE: 12" = 1'-0"

2 ACCEPTABLE SWAY BRACING DETAILS

JT

FEC

SD

S

S

S

R

R

R R

R R R

R R

R

R R

R

R

R

R R R

R

R

RR

C

T T

T

R

R

R

R

R

R

R

RR

C

C

C

C

R

R

RR

R

R

R

R R

R

R

R R

FIRST FLOOR KEY PLAN

N

JKLMMa LaPQ Nb

NO SPRINKLERS IN THIS ROOM

2 2

C1C9

C184

D100A

D151

C1C1

C1D9

C102C103

G163

C189

C188

C185

C187

C186

C193

C180

C182

C181

C105

D194

C1C19

C179

C178

D151C

C101C

C101B

D151B

D150

C101E

C1C2

C101A

C101D

C101

C1C20

#6

C1D5

C186B

1. ANY WORK TO BE DONE THAT AFFECTS AREAS OUTSIDE OF THE SCOPE OF THIS

PROJECT SHALL BE PERFORMED AT NIGHT.

2. PLANS REFLECT THE RATED WALL LOCATIONS. RATED WALLS ARE IDENTIFIED

BY THE COLORED BOLD LINES. SEE BUILDING & LIFE SAFETY REQUIREMENTS

LEGEND FOR WALL RATING DESIGNATIONS.

GENERAL NOTES:

OMAHA | LINCOLN | COLORADO SPRINGS | SIDNEY

FARRIS ENGINEERING

farris-usa.com

FE#:23204…

This is the start of the file's text. The full file is on GovTribe.