This document appears to be a set of architectural drawings and specifications for the "Improve Interior Wayfinding" project at the Harry S Truman Memorial Veterans Hospital in Columbia, Missouri, dated July 22, 2014. The project involves the installation of interior wall graphics, including printed vinyl wallcoverings, letters, and icons, to provide wayfinding and directional information throughout the facility. The drawings provide detailed specifications for the graphic designs, materials, and installation methods in the main lobby, corridors, elevator cores, and other key areas of the hospital. No federal contract opportunity details are included in this document.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Harry S Truman Memorial Veterans Hospital Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
WALL GRAPHICS
Interior Wall Graphics 1
5 - First Floor Main Lobby - Truman’s Quote Elevation Scale: 1/2” = 1’-0” 2.6
1/2”=1’ main lobby - truman’s quote
6’-0”
CENTER
8’-0”
CENTER
EQ
EQ
9’-4” V.I.F.
0’-6” V.I.F.
3’-4”
CENTER
EQ
EQ EQ
12’-1/2” V.I.F.
3’-7” 3’-7”
Footlight MT LightFont:
Color: Pantone Solid Coated
7528 C - Image
7499 C - Background
7530 C- Text
EQ
3/8” 3/8” 3/8”
B 2.10
B Detail @ Wall Section Scale: 1’-0” = 1’-0”
A Detail @ Overlapping Joint Scale: 1’-0” = 1’-0”
A 2.10
Wall Graphic - printed vinyl wallcovering, adhered to 3/8” thick substrate
Artwork by architect.
SIGN CO. TO SUPPLY VINYL GRAPHIC IMAGE
APPLIED TO 3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF SUBSTRATE.
G.C. TO INSTALL ON “Z” CLIPS
EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
2” EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL ON 2 CLIPS
REVEAL STRIP
SIGN CO. TO SUPPLY VINYL
GRAPHIC IMAGE APPLIED TO
3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF
SUBSTRATE. G.C. TO INSTALL
ON “Z” CLIPS
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
REVEAL MOULDING
2”
3/8”
STAINLESS STEEL
CORNER GUARD
2” 3/8”
SIGN CO. TO SUPPLY VINYL GRAPHIC IMAGE
APPLIED TO 3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF SUBSTRATE.
G.C. TO INSTALL ON “Z” CLIPS
EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
2” EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL ON 2 CLIPS
REVEAL STRIP
SIGN CO. TO SUPPLY VINYL
GRAPHIC IMAGE APPLIED TO
3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF
SUBSTRATE. G.C. TO INSTALL
ON “Z” CLIPS
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
REVEAL MOULDING
2”
3/8”
STAINLESS STEEL
CORNER GUARD
2” 3/8”
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
1/2”=1’ entrance corridor to south elevators basement - 6 floor
V.I.F.
EQ.
EQ.
1’-0”
1’-0”
0’-2”
EQ
CENTER
EQ
0’-4”
0’-5”
EQ
EQ
EQ
ALIGN WITH EXISTING
PERPENDICULAR
PARTITION
EXISTING S.S.
CORNER GUARD
EXISTING COLUMN
(DASHED)
ALIGN
WALL GRAPHICS
Interior Wall Graphics 2
2 - First Floor Entrance Corridor Elevation Scale: 1/2” = 1’-0”
APPLIED VINYL
LETTERS & ICON
ON PAINTED WALL
2.7
Wall Graphic - printed vinyl letters & icon adhered to wall by sign company
Colors:
Accent Blue: S-3 Text, Arrow: T-5
Fonts:
Helvetica Bold
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
WALL GRAPHICS
Interior Wall Graphics 3
2.8
3 - First Floor Travel Elevation Scale: 1/4” = 1’-0”
3 - First Floor Pharmacy Elevation Scale: 1/4” = 1’-0”
3 - First Floor Travel & Agent Cashier Elevation Scale: 1/4” = 1’-0”
1/4”=1’ -0” 1st floor Travel & Agent Cashier Elevation
1/4”=1’ -0” 1st floor Travel Elevation
1/4”=1’ -0” 1st floor Outpatient Pharmacy Elevation
CENTER CENTER
3” 6”
3”
3” 6”
3”
3” 6”
3”
CENTER
EQEQ
CENTER
EQEQ
6”
6” 6”
6”
1/4”=1’ -0” 1st floor Travel & Agent Cashier Elevation
1/4”=1’ -0” 1st floor Travel Elevation
1/4”=1’ -0” 1st floor Outpatient Pharmacy Elevation
CENTER CENTER
3” 6”
3”
3” 6”
3”
3” 6”
3”
CENTER
EQEQ
CENTER
EQEQ
6”
6” 6”
6”
1/4”=1’ -0” 1st floor Travel & Agent Cashier Elevation
1/4”=1’ -0” 1st floor Travel Elevation
1/4”=1’ -0” 1st floor Outpatient Pharmacy Elevation
CENTER CENTER
3” 6”
3”
3” 6”
3”
3” 6”
3”
CENTER
EQEQ
CENTER
EQEQ
6”
6” 6”
6”
Wall Graphic - printed vinyl letters & icon adhered to wall by sign company
Colors:
Text, Icons: T-5
Font:
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
4A - Basement North Elevator Core Scale: 1/2” = 1’-0”
Wall Graphic: Printed vinyl letters adhered to wall panels by sign company
Colors:
Accent Blue: S-3 Text, Arrow & Icon: T-5
Fonts:
Helvetica Bold
WALL GRAPHICS
Wall Graphic - Basement 4A & 4B
2.9
1/2”=1’ basement- entrance corridor to elevations north
ALIGN
CENTER
JOINT IN WALL COVERING
0’-9” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-9”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-1” TRIM REVEAL
EQ.
EQ.
0’-9” 1’-0” V.I.F.
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ basement-inside portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
A 2.9
A Detail @ Corner & Overlapping Joint Scale: 1’-0” = 1’-0”
1/2”=1’ basement- entrance corridor to elevations north
ALIGN
CENTER
JOINT IN WALL COVERING
0’-9” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-9”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-1” TRIM REVEAL
EQ.
EQ.
0’-9” 1’-0” V.I.F.
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ basement-inside portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
4B - Basement North Elevator Core Scale: 1/4” = 1’-0”
SIGN CO. TO SUPPLY VINYL GRAPHIC IMAGE
APPLIED TO 3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF SUBSTRATE.
G.C. TO INSTALL ON “Z” CLIPS
EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
2” EXISTING WALL
REVEAL STRIP
3/8” THICK CLAD HIGH IMPACT
WALL PANEL ON 2 CLIPS
REVEAL STRIP
SIGN CO. TO SUPPLY VINYL
GRAPHIC IMAGE APPLIED TO
3/8” SUBSTRATE, IMAGE TO
WRAP AROUND ALL EDGES OF
SUBSTRATE. G.C. TO INSTALL
ON “Z” CLIPS
3/8” THICK CLAD HIGH IMPACT
WALL PANEL
REVEAL MOULDING
2”
3/8”
STAINLESS STEEL
CORNER GUARD
2” 3/8”
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
5A - First Floor North Elevator Core Scale: 1/2” = 1’-0”
1/2”=1’ main lobby - entrance corridor to elevations north
0’-10” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-10”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-5” SOFFIT
0’-1” TRIM REVEAL
1’-10” V.I.F.
EQ.
EQ.
0’-10”
ALIGN
CENTER
JOINT IN WALL COVERING
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ main lobby - portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
WALL GRAPHICS
Wall Graphic - First Floor 5A & 5B
2.10
A 2.9
Wall Graphic: Printed letters & icons adhered to wall panels by sign company
Colors:
Accent Blue: S-3 Text, Arrow & Icon: T-5
Fonts:
Helvetica Bold
1/2”=1’ main lobby - entrance corridor to elevations north
0’-10” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-10”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-5” SOFFIT
0’-1” TRIM REVEAL
1’-10” V.I.F.
EQ.
EQ.
0’-10”
ALIGN
CENTER
JOINT IN WALL COVERING
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ main lobby - portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
5B - First Floor North Elevator Core Scale: 1/4” = 1’-0”
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
18 - Second Floor North Elevator Core Scale: 1/2” = 1’-0”
WALL GRAPHICS
Wall Graphic - Second Floor 6A & 6B
2.11 1/2”=1’ 2nd floor - entrance corridor to elevations north
0’-10” V.I.F.
SOFFIT
ALIGN
CENTER
JOINT IN WALL COVERING
0’-8” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-8”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-1” TRIM REVEAL
0’-4 1/2” 0’-5 1/2”
EQ.
EQ.
0’-8”
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ 2nd floor portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
A 2.9
Wall Graphic: Printed vinyl letters & icons adhered to wall panels by sign company
Colors:
Accent Blue: S-3 Text, Arrow & Icon: T-5
Fonts:
Helvetica Bold
1/2”=1’ 2nd floor - entrance corridor to elevations north
0’-10” V.I.F.
SOFFIT
ALIGN
CENTER
JOINT IN WALL COVERING
0’-8” CENTER1’-6” 1’-6”
0’-2”2” SS CORNER
GUARD EQ EQ
0’-8”
2” SS CORNER
GUARD
0’-2”
0’-4”
EQ
EQ
0’-1” TRIM REVEAL
0’-4 1/2” 0’-5 1/2”
EQ.
EQ.
0’-8”
INSIDE OF PORTAL SOLID
BLUE WALL PANEL
1/4”=1’ 2nd floor portal
INSIDE OF PORTAL
SOLID BLUE WALL PANEL
19 - Second Floor North Elevator Core Scale: 1/4” = 1’-0”
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
WALL GRAPHICS
Typical Elevator Graphic 7
Typical South Elevator Band above door: Printed vinyl letters adhered to wall by sign company
Colors:
Text: T-5
Font:
1/2”=1’ Typ. South Elevator Band Above Door Basement, 2nd, 3rd, 4th, 5th and 6th Floor
EXISTING TV
0’-11 3/4”
- 1’-3/4” V.I.F.
1”=1’ Typ. South Elevator Band Above Door Basement, 2nd, 3rd, 4th, 5th and 6th Floor
CENTER
EQEQ
0’-11 3/4”
- 1’-0” V.I.F.
CENTER
0’-4 1/2” CENTER
EQ
EQ
0’- 3/4”
0’-4 1/2” CENTER
1/2”=1’ Typ. South Elevator Band Above Door Basement, 2nd, 3rd, 4th, 5th and 6th Floor
EXISTING TV
0’-11 3/4”
- 1’-3/4” V.I.F.
1”=1’ Typ. South Elevator Band Above Door Basement, 2nd, 3rd, 4th, 5th and 6th Floor
CENTER
EQEQ
0’-11 3/4”
- 1’-0” V.I.F.
CENTER
0’-4 1/2” CENTER
EQ
EQ
0’- 3/4”
0’-4 1/2” CENTER
7 - Typical South Elevator Band Above Door Basement, 1st, 2nd, 3rd, 4th 5th and 6th Floor Scale: 1/2” = 1’-0”
Typical South Elevator Band Above Door Basement, 1st, 2nd, 3rd, 4th 5th and 6th Floor Scale: 1” = 1’-0”
Key plan Scale: NTS
N
N
SA
B
2.12
APPLIED VINYL LETTERS
ON PAINTED WALL
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
WALL GRAPHICS
Typical Elevator Graphic 8 & 9
Typical North A & B Elevator Band above door: Printed vinyl letters adhered to wall by sign company
Colors:
Text: T-5
Font:
Helvetica Bold
CENTER
EQEQ
EQ
EQ
CENTER
EQEQ
CENTER
0’-10”
0’-4 1/2” CENTER
EQ
EQ
0’- 3/4”
0’-4 1/2” CENTER
1/2”=1’ Typ. North B Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’- 3 1/4” V.I.F.
0’-4 1/2” CENTER
0’-11 3/4”
- 1’-5 3/4” V.I.F.
1/2”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
1”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’-5 3/4” V.I.F.
CENTER
EQEQ
EQ
EQ
CENTER
EQEQ
CENTER
0’-10”
0’-4 1/2” CENTER
EQ
EQ
0’- 3/4”
0’-4 1/2” CENTER
1/2”=1’ Typ. North B Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’- 3 1/4” V.I.F.
0’-4 1/2” CENTER
0’-11 3/4”
- 1’-5 3/4” V.I.F.
1/2”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
1”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’-5 3/4” V.I.F.
8 - Typical North A Elevator Band Above Door Basement, 1st 2nd Floor Scale: 1/2” = 1’-0”
CENTER
EQEQ
EQ
EQ
CENTER
EQEQ
CENTER
0’-10”
0’-4 1/2” CENTER
EQ
EQ
0’- 3/4”
0’-4 1/2” CENTER
1/2”=1’ Typ. North B Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’- 3 1/4” V.I.F.
0’-4 1/2” CENTER
0’-11 3/4”
- 1’-5 3/4” V.I.F.
1/2”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
1”=1’ Typ. North A Elevator Band Above Door Basement, 1st Floor, 2nd Floor
0’-11 3/4”
- 1’-5 3/4” V.I.F.
Typical North A Elevator Band Above Door Basement, 1st 2nd Floor Scale: 1” = 1’-0”
9 - Typical North B Elevator Band Above Door Basement, 1st 2nd Floor Scale: 1/2” = 1’-0”
Key plan Scale: NTS
N
N
SA
B
2.13
APPLIED VINYL LETTERS
ON PAINTED WALL
Columbia, Missouri Improve Interior Wayfinding
Date: July 22, 2014 Project: 1122.01
1 Memorial Drive, Suite 1800
St. Louis, Missouri 63102
Phone: (314) 621 4343
Fax: (314) 621 0261
Email: info@fox-arch.com
10 - Typical South Elevator Door Basement - 6th Floor Scale: 1” = 1’-0”
Typical North A & B & South Elevator Door Wall Graphic: Printed vinyl wallcovering adhered to elevator door by sign company
Colors:
Background: S-1 Text: S-3 Highlighted Text: T-5
Font: Helvetica Medium
WALL GRAPHICS
Typical Elevator Graphic 10 & 11
BASEMENT
1ST FLOOR
EQ.EQ.
CENTER
5TH FLOOR
BASEMENT
4TH FLOOR
3RD FLOOR
2ND FLOOR
6TH FLOOR
EQ.EQ.
CENTER
1”=1’ Typ. North A & B Elevator Door basement - 2nd Floor
EQ.
EQ.
1’-8” 2’-0”
4’-0”
0’-2”
0’-1” 0’-2”
CENTER EQ.EQ. 2’-0”
1’-3 1/2”
CENTER
CENTER
1”=1’ Typ. South Elevator Door basement -6th Floor
EQ.
EQ.
1’-8” 2’-0”
4’-0”
0’-2”
0’-1” 0’-2”
CENTER EQ.EQ. 2’-0”
1’-3 1/2”
CENTER
CENTER
BASEMENT
1ST FLOOR
EQ.EQ.
CENTER
5TH FLOOR
BASEMENT
4TH FLOOR
3RD FLOOR
2ND FLOOR
6TH FLOOR
EQ.EQ.
CENTER
1”=1’ Typ. North A & B Elevator Door basement - 2nd Floor
EQ.
EQ.
1’-8” 2’-0”
4’-0”
0’-2”
0’-1” 0’-2”
CENTER EQ.EQ. 2’-0”
1’-3 1/2”
CENTER
CENTER
1”=1’ Typ. South Elevator Door basement -6th Floor
EQ.
EQ.
1’-8” 2’-0”
4’-0”
0’-2”
0’-1” 0’-2”
CENTER EQ.EQ. 2’-0”
1’-3 1/2”
CENTER
CENTER
Key plan Scale: NTS
N
N
SA
B
11 - Typical North A & B Elevator Door Basement - 2nd Floor Scale: 1” = 1’-0”
2.14