P-2026-000067 Addendum FOUR.pdf

PDF 215 KB Posted

Attached to
South Region Operations Center (SROC) - Paint Entire Complex
Solicitation number
IFB 410 P-2026-000067 6
Issued by
Palm Beach County, Florida

About this file

This is Addendum Four to a painting contract for the Palm Beach County Board of County Commissioners, Facilities Development and Operations Department, Capital Improvements Division, for the South Region Operations Center (SROC) Paint Entire Complex project (P-2026-000067). The addendum addresses responses to requests for information from prospective bidders regarding paint and coating product substitutions and scope clarifications. The project involves preparing, priming, and painting all wall surfaces of eleven buildings (K, L, N, O, P, Q, R, M, T, W), two sides of all exterior doors and frames, exterior of all roll-up doors, the chiller enclosure, front monument sign, bollards, fire backflow piping, knee walls, area containment walls, light poles, and all previously painted surfaces connected to or in direct relation to these areas according to Tnemec Coatings Inc. specifications. Bidders must acknowledge receipt of this addendum and all previously issued addenda by signing and attaching the addendum to their bid form, with failure to do so potentially resulting in bidder disqualification.

The addendum denies a substitution request from ID Painting Corp. to use Sherwin Williams Paint and Coatings in place of the specified Tnemec products, detailing specific deficiencies in ASTM testing results, solids by volume, durability performance, salt fog exposure hours, adhesion strength, and exterior weathering resistance. The response clarifies that Sherwin Williams products do not provide sufficient documentation to qualify as equal or better alternatives to the specified high-performance Tnemec coatings, which are designed for South Florida's extreme weathering conditions. An additional clarification was provided to Cunano Builders Corporation confirming that utility doors, excluding roll-up doors, are included in the painting scope of work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BOARD OF COUNTY COMMISSIONERS

PALM BEACH COUNTY, FLORIDA

FACILITIES DEVELOPMENT AND OPERATIONS DEPARTMENT

CAPITAL IMPROVEMENTS DIVISION

PROJECT NAME: South Region Operations Center (SROC) - Paint Entire Complex

PROJECT NUMBER: P-2026-000067

ADDENDUM NUMBER: FOUR

DATE OF ISSUANCE: 7/7/2026

TO: Prospective Bidders

This addendum forms a part of the contract documents, modifies the original bid documents and shall be as binding as if contained therein. Acknowledge receipt of this addendum in the space provided on the "Bid Proposal Form". Failure to do so may subject the Bidder to disqualification.

This Addendum consists of two (2) pages.

RESPONSES TO REQUESTS FOR INFORMATION:

1. ID PAINTING CORP.

Question #1: Substitution request to use Sherwin Willams Paint and Coatings

Response: The Manufacturer did not submit sufficient ASTM Testing Results to be included as equal or better options to the specified basis of design high performance coatings. Examples below.

• Submittal does not include ASTM Testing for Macropoxy 646.

• SW HI Solids Polyurethane is less Solids by Volume than Tnemec Series

1095 EnduraShield.

• SW HI Solids Polyurethane does not list QUV Testing for exterior UV

Exposure.

• SW HI Solids Polyurethane does not list ASTM D5894 for Cyclic Salt

Fog/UV Exposure.

• Tnemec Series 1095 EnduraShield provides a harder finish, ASTM

D3363.

• SW Fluorokem HS does not meet AAMA 2604 or AAMA 2605 for extreme South Florida Weathering. Tnemec Series 1070 Fluoronar meets both.

• Tnemec Series 1070 Fluoronar lists testing in B117 Salt fog for over

10,000 hours, while SW Fluorokem HS is only 3,000 hours.

• SW Fluorokem HS lists "Pass" for ASTM D4141 EMMAQUA. This test method for UV Resistance is not a pass or fail, there should be quantitative data.

• SW Fluorokem HS does not list exterior UV results, including ASTM

D4141, ASTM D6695, or ASTM D4587.

• Tnemec Series 1070 Fluoronar provides a harder finish per ASTM D3363.

• SW Macropoxy HS is lower Solids by Volume than Series 135

Chembuild.

• Tnemec Series 135 Chembuild lists better adhesion results per ASTM

D4541.

• Tnemec Series 135 Chembuild lists 4,000 hours when testing over rust metal in ASTM B117 Salt Fog, while SW Macropoxy HS only lists 1,000 hours on clean, abrasive blasted steel.

• SW Conflex XL is lower Solids by Volume than Series 156 EnviroCrete.

• SW Conflex XL does not list adhesion strength, or QUV Exposure.

• SW Duration is less Solids by Volume than Series 1026 Enduratone.

• SW Duration does not list any ASTM Performance Results. Such as, MVT, QUV Exposure, Xenon Arc Weathering, or any exterior testing.

2. CUNANO BUILDERS CORPORATION

Question #1: Are the utility doors (excluding the roll-up doors) going to be painted?

Response:

See Scope of Work item “a.”

a. The contractor shall prepare, prime, and paint all wall surfaces of buildings K, L, N, O, P,Q, R, M, T, W, including 2 sides of all exterior doors and frames, exterior of all rollup doors, the chiller enclosure, front monument sign, bollards, fire backflow piping, knee walls, area containment walls, light poles, and all previously painted surfaces connected to or in direct relation to these areas according to the specifications provided by Tnemec Coatings Inc. attached as Exhibit

“1”.

PLEASE ACKNOWLEDGE RECEIPT OF THIS ADDENDUM NO. FOUR (4), AND ANY

PREVIOUSLY ISSUED ADDENDA, BY SIGNING BELOW AND ATTACHING THIS

ADDENDUM TO YOUR BID FORM. THIS ADDENDUM MUST BE SIGNED BY AN

AUTHORIZED AGENT AND ATTACHED TO YOUR BID FORM, AND RECEIPT OF

THIS ADDENDUM MUST BE ACKNOWLEDGED ON THE “BID PROPOSAL FORM”.

FAILURE TO DO THIS MAY RESULT IN BIDDER’S DISQUALIFICATION.

ACKNOWLEDGMENT OF RECEIPT: _____________________________________

END OF ADDENDUM - 4