This document is a civil engineering drawing for the Tomoka Farms Road Landfill 2024 Gas Collection and Control System (GCCS) Expansion, prepared by SCS Engineers for the Volusia County Solid Waste and Recycling Division Public Works Department. The drawing represents the existing conditions of the South Cell, detailing the current landfill gas infrastructure including extraction wells (EW), horizontal collectors (HC), air supply pipes, condensate discharge pipes, leachate sumps, and cell boundaries. The drawing is dated July 2025 and uses an aerial survey from June 28, 2023, with previous landfill gas collection system as-built drawings referenced from HDR (August 24, 2021) and Peavey & Associates (August 11, 2023, and January 24, 2025).

The technical drawing provides a comprehensive site plan with topographical contours, showing a detailed network of gas collection pipes ranging from 4" to 12" in diameter, multiple extraction wells, and associated infrastructure. The drawing includes a legend identifying various components such as existing wells, horizontal collectors, access risers, leachate sumps, and cell boundaries. The scale is 1" = 125' with north orientation, and the document is professionally sealed by a Professional Engineer named Stephanie M. Liptak, indicating compliance with engineering standards and regulatory requirements for landfill gas management and infrastructure planning.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U E

4 -12"Ø HDPE PIPES

HC

HC

HC

HC

10"

EW-25R

EW-2

EW-59

EW-1

EW-60

EW-56

EW-55

EW-57

LS-1LCR-1

HC

HC

HC

HCEW-30

HWLCO-2

HWLCO-1

6"

10"

4"

6"

6"

EW-73

EW-57

6"

10"

6"

V-1

CV-1AV-1

V-2CV-2

AV-2

6"

8"

10"

8"

10"

8"

8" 6"

HC-18B

HC-8B

HC-7B

HC-26B

HW-20B HW-21B

HW-23B

HW-22B

EW-26

EW-77

6"

EW-29EW-28

EW-27

HC-11B

EW-88

EW-58

CS-14

CS-17

AP-16

AP-4

AP-7 AP-15AP-6

CS-12

CS-3

AP-20CS-13AP-21CS-15 AP-8

AP-5 CS-16CS-18

AP-9

EW-926"

P

DRAWING NO.

SCALE:

DATE:

PR

O

J.

N

O

DS

N

. B Y:

DW

N

. B Y:

CH

K.

B Y:

Q /A

R

VW

B Y:

AP

P.

B Y:

PR

O

JE

CT

T

IT

LE

CADD FILE:

SH

EE

T

TI

TL

E

CL

IE

N T

SHEET of

DA

TE

RE

V

DE

SC

RI

PT

IO

N

CH

K.

BY

S

C S

E N

G

IN

E E

R S

S

TE

A R

N S

, C O

N R

A D

A N

D S

C H

M

ID

T C

O N

S U

LT

IN

G E

N G

IN

E

E R

S

S

S E

M O

R A

N B

LV

D

, O R

LA

N

D O

, F L

P

H

7)

-3

F

A X

N O

3)

-1

FL

O

R

ID

A F

IR

M

R E

G

IS

TR

A

TI

O

N R

Y-

AS SHOWN

JULY 2025

SM

L

SM

L

KG

B

SM

L

SM

L

.1

TO

M

O K

A F

A R

M S

R O

A D

L A

N D

FI

LL

G C

C S

E X

P A

N S

IO

N

V O

LU

S

IA

C

O U

N

TY

S O

LI

D

W A

S

TE

A N

D R

E C

Y C

LI

N

G D

IV

IS

IO

N

P U

B

LI

C W

O R

K S

D E

P A

R

TM

E N

T

This item has been digitally signed and sealed by Stephanie M. Liptak, P.E. on the date adjacent to the seal.

Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

E X

IS

TI

N G

C O

N D

IT

IO

N S

S O

U

TH

C E

LL

09219088.14_EX-COND.DWG

NOTES:

1. EXISTING CONTOURS BASED ON AERIAL SURVEY PROVIDED BY HDR DATED

JUNE 28, 2023

2. LANDFILL GAS COLLECTION AND CONTROL SYSTEM AS-BUILT DRAWINGS BY

HDR, ON AUGUST 24, 2021, AND PEAVEY & ASSOCIATES, ON AUGUST 11,

2023, AND JANUARY 24, 2025.

EXISTING AIR SUPPLY PIPE

EXISTING CONDENSATE DISCHARGE PIPE

EXISTING LFG HEADER / LATERAL PIPE

EXISTING LFG HORIZONTAL COLLECTOR PIPE

EXISTING BLIND FLANGE

EXISTING CONDENSATE SUMP

EXISTING LEACHATE CLEANOUT

EXISTING WELL - GAS EXTRACTION

EXISTING WELL - HORIZONTAL

EXISTING HORIZONTAL WELL REMOTE

AP-## EXISTING ACCESS RISER

EXISTING LEACHATE SUMP

EXISTING LEACHATE CLEANOUT RISER WELLHEADHWLCO-##

LS-##

EXISTING CELL BOUNDARY

EW-##

HW-##B

HC-##A

CS-##

LCR-##

LEGEND:

0 12562.5

1" = 125'

250N

AutoCAD SHX Text 4-12"HDPE PIPES 1-E INV ELEV=.28.10 1-W INV. ELEV.=28.45 2-E INV ELEV=28.20 2-W INV. ELEV.=28.30 3-E INV ELEV.=28.30 3-W INV. ELEV.=28.40 4-E INV ELEV.=28.30 4-W INV. ELEV.=28.40

AutoCAD SHX Text

CONC. MES WITH RIPRAP

AutoCAD SHX Text

CONC. MES

AutoCAD SHX Text

(APPROXIMATE)

AutoCAD SHX Text

LIMITS OF REFUSE

AutoCAD SHX Text 5.0%

AutoCAD SHX Text

CS-4

AutoCAD SHX Text 4"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 16"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text

RISER

AutoCAD SHX Text

BLOWER FLARE

AutoCAD SHX Text

STATION

AutoCAD SHX Text

CS-1

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text

LIMITS OF REFUSE

AutoCAD SHX Text

(APPROXIMATE)

AutoCAD SHX Text 14"%%c

AutoCAD SHX Text 16"%%c

AutoCAD SHX Text 14"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 4"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text

CS-3

AutoCAD SHX Text 6"%%c

AutoCAD SHX Text 8"%%c

AutoCAD SHX Text 10"%%c

AutoCAD SHX Text 4"%%c

AutoCAD SHX Text 16"%%c

AutoCAD SHX Text

EW-31

AutoCAD SHX Text

EW-33

AutoCAD SHX Text

EW-32

AutoCAD SHX Text

EW-7

AutoCAD SHX Text

EW-8

AutoCAD SHX Text

EW-46

AutoCAD SHX Text

EW-28

AutoCAD SHX Text

EW-2

AutoCAD SHX Text

EW-3

AutoCAD SHX Text

EW-30

AutoCAD SHX Text

EW-5

AutoCAD SHX Text

EW-4

AutoCAD SHX Text

EW-1

AutoCAD SHX Text

TYPICAL EXTRACTION WELL

AutoCAD SHX Text

LATERAL TRENCH

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

SUMP #2

AutoCAD SHX Text

SUMP #3

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

CONDENSATE

AutoCAD SHX Text

SUMP #4

AutoCAD SHX Text

BLIND FLANGE

AutoCAD SHX Text

TOP ELEV. = 88.28

AutoCAD SHX Text

WELL 2902

AutoCAD SHX Text

WELL 4402

AutoCAD SHX Text

WELL 4502

AutoCAD SHX Text

NW-05

AutoCAD SHX Text

NW-06

AutoCAD SHX Text

NW-07

AutoCAD SHX Text

WELL 4002

AutoCAD SHX Text

WELL 3902

AutoCAD SHX Text

NW-10

AutoCAD SHX Text

WELL 4702

AutoCAD SHX Text

NW-12

AutoCAD SHX Text

EW-48

AutoCAD SHX Text

NW-14

AutoCAD SHX Text

NW-08

AutoCAD SHX Text

NW-02

AutoCAD SHX Text

EXISTING CORRUGATED PLASTIC

AutoCAD SHX Text

STORMWATER LINES (TYP,)

AutoCAD SHX Text 22"

AutoCAD SHX Text 14"

AutoCAD SHX Text 16"

AutoCAD SHX Text 10"

AutoCAD SHX Text

LINE SECTIONS INSTALLED

AutoCAD SHX Text

CORRUGATED PLASTIC STORMWATER

AutoCAD SHX Text

BY VOLUSIA COUNTY (TYP.)

AutoCAD SHX Text 10"

AutoCAD SHX Text

BLIND

AutoCAD SHX Text

FLANGE

AutoCAD SHX Text

CS-2

Sheets and Views
EXISTING CONDITIONS SOUTH CELL

File details come from the government source that posted it. Updated .