National Institutes of Health ‐ Program of Requirements:
National Institute on Aging
NIH Division of Facilities Planning Page 54 of 54 RMF Engineers, Inc. │ Gaudreau, Inc. Architects January 11, 2016
12.0 Appendix
Appendix A: Model Plans
Appendix B: Space Data Sheets
Appendix C: Equipment Lists
Appendix D: NIH Design Requirements Manual (DRM) Chapter 11 Telecommunication
Amendment: NIH DRM Chapter 11
Appendix E: Pharmacy Requirement Design Guidelines
Appendix F: MRI Phillips Requirements
Appendix G: Sustainability Supplemental Information
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects
Appendix A: Model Plans
The Model Plans included in this Appendix are for illustrative purposes only and are to be used in conjunction with the Space Data Sheets found in Appendix B. Model Plan and Space Data Sheet associations can be found in Section 4, 4.2.3, Space Summary Form. The floor plans depicted are not intended to represent the final design layout but are being used to provide general information on the scope of work. The final design will be generated after the lease location has been determined.
LEGEND
Plan Legend
MAGNETIC WHITE BOARD
FLAT PANEL DISPLAY
REFRIGERATOR w/
WATER HOOK-UP
FREEZER
MICROWAVE
DISHWASHER
SINK
COPIER/FAX/SCANNER
RECYCLE/TRASH
SECURITY CAMERA
R
MW
S
DW
MFD
REC
SC
F
National Institutes of Health - Program of Requirements:
Model Plans
RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan Legend
Office (210 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan A1
Allocated Model Plan
Office (120 SF)
2' 4'0 8'
Workstation (30 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan A2
Workstation (48 SF)
2' 4'0 8'
Workstation (64 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
Workstation (30 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan B1
Protocol Meeting Room (252 SF, 8 Seats)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C1
Conference Room (540 SF, 30 Seats)
2' 4'0 8'
AV Closet 30 sf
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C2
Reception / Waiting Room (370 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
MFD
Reception Office (120 SF)
EXISTING EQUIPMENT
1. Zerox Copier
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C3
Participant Day Lounge (280 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C4
Equipment Storage (190 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C5
Medical Records Room (350 SF)
2' 4'0 8'
3.
2.
1.
1.
EXISTING EQUIPMENT
1. Aurora Mobile Storage System
2 Singles
2. Aurora Mobile Storage System
1 Double
3. Shelving on Walls
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C6
Staff Lounge (180 SF)
2' 4'0 8'
R
M W
1.
EXISTING EQUIPMENT
1. 30 Lockers
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C7
Staff Lounge (140 SF)
2' 4'0 8'
M W
1.
2.
EXISTING EQUIPMENT
1. Magic Chef Refridgerator / Freezer
2. Twist Air Refridgerator, Canby
Design Freezer on Top
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C8
Coffee Bar (60 SF)
2' 4'0 8'
S
R
MW
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C9
IT Office (220 SF; 3 @ 64 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C10
NIA Data Closet (2@ 80 SF) LAN Closet (2 @ 80 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C11
Business Center (300 SF)
2' 4'0 8'
M F
D
REC
REC
EXISTING EQUIPMENT
1. Zerox Copier
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C12
Lactation Room (80 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan C13
Private Participant Room (270 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D1
Semi-Private Participant
Room
(500 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D2
Semi-Private Participant Room (270 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D3
Clamp Room (500 SF)
2' 4'0 8'
4.
1. 2.
5. 5. 5. 5.
3.
R
EXISTING EQUIPMENT
1. YSI Turntable 2710
2. Supply Stand for YSI Equipment
3. Eppendorf Centrifuge 5415C
4. Sonall Centrifuge Legend RT
5. Harvard Pumps
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D4
Nourishment (35 SF)
2' 4'0 8'
MW
R
1.
House Keeping Closet (40 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
EXISTING EQUIPMENT
1. Scotsman Touch Free Water/Ice
Dispenser
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D5
Team Lead Room (200 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D6
IT Support Assistant (30 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D7
Nurse's Station (200 SF)
2' 4'0 8'
Medication Room (50 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
R
1.
R
EXISTING EQUIPMENT
1. Pyxis
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D8
Nurse Practitioner Office (128 SF)
2' 4'0 8'
Nurse Practitioner Files (80 SF)
FILE CLOSET
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D9
Clinical Recruiters Office (128 SF)
2' 4'0 8'
Recruiters Office Files (80 SF)
FILE CLOSET
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D10
Pharmacy w/Cleam Room (500 SF)
2' 4'0 8'
Pharmacy Clean Closet (40 SF)
3.
1.
2.
4.
6.
5.
EXISTING EQUIPMENT
1. So Low Ultra Low Freezer
2. Norlake Refridgerator
3. Norlake Tow Way Rrefridgerator
4. Skytron Sink
5. Steriguard BSC
6. Quincy Lab Incubator
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D11
Clean Utility (190 SF)
2' 4'0 8'
1.
Soiled Utility (70 SF)
SCALE: 1/4" = 1'-0"
2' 4'0 8'
EXISTING EQUIPMENT
1. Scotsman Touch Free Water/Ice
Dispenser
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan D12
Exam Room (130 SF)
2' 4'0 8'
1.
2.
3.
4.
5. 6.
7.
1.
3.
2.
EXISTING EQUIPMENT
1. Exam Table Model 5140-6
2. EMG
3. GE View Box
4. Nicolet
5. Nicolet EA-4
6. Viasys
7. Welch Allyn DX system
EXISTING EQUIPMENT
(Typical)
1. Exam Table Model 5140-6
2. Welch Allyn CX Unit
3. GE View Box
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E1
Procedure Room (400 SF)
2' 4'0 8'
2.
5.
4. 3.
6.
1.
R
R
EXISTING EQUIPMENT
1. Bio-safety Cabinet Nuair 3828530
2. Flammable Safety Cabinet
3. Prima Extend Arm (ceiling mounted)
4. Hill Rom Surgical Light (ceiling mounted)
5. View Box
6. Sterix Flexmatic Sink
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E2
Infusion Room (800 SF)
2' 4'0 8'
4. 4. 4.
4.
4.
8.
7.
6.
8.
8. 8. 8.
1.
5.
3.
2.2.
2.
2. 2.
EXISTING EQUIPMENT
1. Centrifuge, Sorval Legend
2. Television (ceiling)
3. Entertainment Center (ceiling)
4. Stryker #3110 Recliners
5. Hill Rom Stretcher
6. Thermo 900 -80 Freezer
7. Hill Rom Stretcher
8. Hill Rom Support Carts
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E3
Apheresis Room (740 SF)
2' 4'0 8'
Office (80 sf)
8.
7.
4.4.4. 1.
2.
1.
2. 2.
3.
6.
EXISTING EQUIPMENT
1. Hill Rom Carts
2. Dacor 5211 Recliners
3. Entertainment Center
4. Cobe Spectra
6. Mini Lab Bench w/drawers
& doors underneath
7. Sink
8. Enthermics EC770 Blanket Warmer
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E4
Lab / Blood Draw Room (200 SF)
2' 4'0 8'
4.
1. 2.
3.
EXISTING EQUIPMENT
1. Thermo 708 -80 Freezer
2. Baxter Cryo Fridge 1lr421 aba
3. Stadiometer
4. SR Scale 125L
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E5
Consult Room (100 SF)
3.
SCALE: 1/4" = 1'-0"
2' 4'0 8' Vision Testing (100 SF)Tongue Testing (100 SF)
3.
2. 2.
4. 5.
6.1.
2.
EXISTING EQUIPMENT
1. GE View Box
EXISTING EQUIPMENT
1. Tongue Table w/Nikon D5000
(on stand)
2. Zeiss Axiovert 200 Scope w/
HAL Imager
EXISTING EQUIPMENT
1. Visual Accuity Charts
2. Lights
3. Zeiss Ocular Peripheral Vision
Scope
4. Nidek Auto Keratometer
5. Reichert al200 Auto Lensometer
6. Proprioception System
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E6
Testing Rooms (110 SF x3)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E7
Testing Work Room (200 SF)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E8
Doppler Testing (100 SF x2)
2' 4'0 8'
2.1. 1.
2.
3.
EXISTING EQUIPMENT
1. Doppler/ABI Colin
2. Hill Rom Stretcher w/BP Cuffs
EXISTING EQUIPMENT
1. Hill Rom 511 Stretcher
2. Phillips IE33
3. Support Stand
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E9
Testing Storage (90 SF x2)
2' 4'0 8'
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E10
2' 4'0 8'
Tech Work (250 SF)
EXISTING EQUIPMENT
1. Code Cart Harloff Metronic Lifepack 12
2. Treadmill
3. Medgraphic Computer Stand
4. GE Medical Bedside Monitoring System
5. Herman Miller Supply Stand
6. Overhead "Room in Use"
SCALE: 1/4" = 1'-0"
2' 4'0 8'
Treadmill Testing (175 SF)
1.
2.
3.
4.5.
4.
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E11
Strength Testing (170 SF)
1.
2. 1.
3.
4.
5.
EXISTING EQUIPMENT
1. Biodex Computer Support Stand
2. Biodex Strength Machine
3. Kim Com Strength Machine
4. Kim Com Control Panel
5. Overhead "Room in Use"
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E12
DEXA Testing (140 SF)
2.
1.
3.
EXISTING EQUIPMENT
1. GE DXA Scanner
2. Computer Stand
3. Overhead "Room in Use"
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E13
VEMP Testing (110 SF)
1.
3.
4.
2.
2.
EXISTING EQUIPMENT
1. Intercoustics
2. Computer Stations
3. Reclining Chair
4. Overhead "Room In Use Lights"
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E14
General Storage (230 SF)
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E15
Gait Testing (390 SF)
1.
2.
1.
1.
1.
1.
1.
1.
1.
1.
1.3.
EXISTING EQUIPMENT
1. Vicon Cameras Monfrotto 3047
(wall mounted)
2. Computer Stations
3. Raised Floor (entire room)
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E16
Clean Utility (200 SF)
1.
EXISTING EQUIPMENT
1. Scotsman Touch Free Water/Ice
Dispenser
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E17
Equipment Room 390 sf
Magnet Room 490 sf
Control Room 350 sf
ADA Compliant Locker/Toilet Room 80 sf
Storage 35 sf
Waiting Room 150 sf
Corridor 157 sf
MRI Suite (1,652 SF)
SCALE: 1/8" = 1'-0"
4' 8'0 16'
1.
2.3.
ADA Bench
"Magnet in Use" sign above door
"Magnet in Use" sign above door
Raised Floor - This room only
EXISTING EQUIPMENT
1. Enthermics ec340 Blanket Warmer
2. Ferno Washington Stretcher
3. Contrast Injector, Spectra Solaris
National Institutes of Health - Program of Requirements:
Model Plans
NIH Division of Planning RMF Engineers, Inc. │ Gaudreau, Inc. Architects Model Plan E18
Coffee Bar
60 sf
67 sf
67 sfMEN
WOMEN
PRIVATE
PARTICIPANT
ROOM
270 SF
WCWC
PRIVATE
PARTICIPANT
ROOM
270 SF
WCWC
PRIVATE
PARTICIPANT
ROOM
270 SF
PRIVATE
PARTICIPANT
ROOM
270 SF
PRIVATE
PARTICIPANT
ROOM
270 SF
WC
SEMI - PRIVATE
PARTICIPANT
ROOM
500 SF
SEMI -PRIVATE
PARTICIPANT
ROOM
270 SF
SEMI - PRIVATE
PARTICIPANT
ROOM
500 SF
SEMI - PRIVATE
PARTICIPANT
ROOM
500 SF
WC
WCWCWCWC
CLAMP ROOM
500 SF
NURSES
STATION
200 SF
HOUSE KPING
40 SF
NOUR
35 SF
PHARMACY
W/ CLEAN
ROOM
500 SF
NURSE
PRACTITIONER
OFFICE
128 SF
CLINICAL
RECRUITERS
OFFICE
128 SF
RECRU
FILE
ROOM
80 SF
NURSE
PRAC
FILE
80 SF
CLEAN UTILITY
190 SF
IN PARTICIPANT AREAS
EXAM
ROOM
130 SF
EXAM
ROOM
130 SF
EXAM
ROOM
130 SF
EXAMROOM130 SF
EXAMROOM130 SF
PROCEDURE
ROOM
400 SF
INFUSION
ROOM
800 SF
APHERESIS
ROOM
740 SF
TREADMILL ROOM
175 SF
GAIT TESTING
390 SF
TESTING
DOPPLER
100 SF
TESTING
DOPPLER
100 SF
LAB
BLOOD
SAMPLE
200 SF
VISION
TESTING
100 SF
TONGUE
TESTING
100 SF
CONSULT
ROOM
100 SF
CONSULTROOM100 SF
TESTING
ROOM
110 SF
STRENGTH
175 SF
MED RM
50 SF
IT SUPPORT
ASSIST 30 SF
SUPER NURSE
SPEC 30 SF
SOILED
UTILITY
70 SF
SUPPORT SPACE
RESEARCH OFFICE SPACE
PARTICIPANT
LOUNGE
280 SF
TEAM
LEADS
OFFICE
200 SF
PHARM CL CL
44 SF
WC
STAFF LOUNGE
180 SF
NIA DATA
CLOSET
80 SF
LAN CLOSET
80 SF
RECEPTION
150 SF WAITING AREA
420 SF
CONFERENCE ROOM
530 SF
PROTOCOL
MEETING
ROOM
250 SF
BUSINESS
CENTER
300 SF RECEPTION
170 SF
MEDICAL
RECORDS
350 SF
STAFF
LOUNGE/
STORAGE
140 SF
NIA DATA
CLOSET
90 SF
TESTING
WORK
ROOM
200 SF
ELEVATOR
LOBBY
TESTING
STOR. 90 SF
VEMP
TESTING
110 SF
TESTING
ROOM
110 SF
TESTING
ROOM
110 SF
GENERAL
STORAGE
230 SF
EQUIP
STORAGE
190 SF
LAN CLOSET
80 SF
OFFICE A
210 SF
OFFICE B
120 SF
DEXA ROOM
120 SFWORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION B
48 SF
IT OFFICE
220 SF
WORKSTATION A
30 SF
AV
50 SF
TECH
WORK
ROOM
250 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORK
STATION C
64 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
WORKSTATION A
30 SF
CLEAN
UTILITY
200 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
WORK
STATION C
64 SF
OFFICE B
120 SF
OFFICE B
120 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
WORKSTATION D
30 SF
COPY STATION
60 SF
TOILET
40 SF
TOILET
40 SF
OUT PARTICIPANT / PROTOCOL
TESTING AREAS
NOTE:
THIS STUDY PLAN IS INCLUDED FOR GENERAL
ILLUSTRATIVE PURPOSES ONLY AND IS NOT
INTENDED TO DEPICT THE FINAL DESIGN LAYOUT.
National Institutes of Health - Program of Requirements:
Model Plans
RMF Engineers, Inc. │ Gaudreau, Inc. Architects Study Plan
RMF Engineers, Inc. │ Gaudreau, Inc. Architects
Appendix B: Space Data Sheets
The Space Data Sheets included in this Appendix are for information only and are to be reviewed in conjunction with the Model Plans found in Appendix A. Model Plan and Space Data Sheet associations can be found in Section 4, 4.2.3, Space Summary Forms. The Space Data Sheets are not intended to represent the final design content but are being used to provide general information on the scope of work. The final design will be generated after the lease location has been determined.
Space Data Sheets National Institute on Aging
Space Type: Office and Support
Space Type: Office SF: 210 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3' x 7' Wood Electrical Raceway
Frames: Aluminum frames with glass panel AV Display / Control
Windows: Room Control
Glass Aluminum framed glass front along door wall Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Office should be located in the Clinical Director's suite and adjacent to associated staff. Natural light is preferable.
Staff office furnished and appointed to accommodate private / confidential level work and periodic in-room meetings.
Space Data 1
Space Type: Office and Support
Space Type: Office SF: 120 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3' x 7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Office should be located adjacent to associated staff.
Staff office furnished and appointed to accommodate private / confidential level work and periodic in-room meetings.
Space Data 1a
Space Type: Office and Support
Space Type: Workstation SF: 64, 48, 30 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors Electrical Raceway
Frames: AV Display / Control
Windows: Room Control
Glass Microphones
Card access Whips
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Workstations should be located adjacent to associated staff or clinical function.
Open workstation to provide efficient accommodatiojn of staff and collaborative work environment.
Surrounding panel heights may vary.
Space Data 1b
All power and telecom/data services shall be provided in a concealed fashion either via recessed floor boxes or wall boxes. No power poles will be permitted.
Workstation panel height will be no taller than 5' A.F.F. Coordinate all lighting and HVAC distribution / control and utility services with this requirement.
Space Type: Office and Support
Space Type: Meeting Room SF: 252 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Aluminum frames with glass panel AV Display / Control
Windows: Room Control
Glass Aluminum framed with glass front along door wall Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1c
Meeting room should be located adjacent to associated clinical function.
Space furnished and appointed to accommodate private / confidential meetings.
Provide dimmable lighting controls and room darkening along all glass walls
Space Type: Office and Support
Space Type: Conference Rm/AV SF: 540 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry Lockable with wood veneer
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Podium
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink GFI within 6' of sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating Analog Phone
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1d
Conference room should be located adjacent to reception area / suite entry and direct access to AV closet
Space furnished and appointed to accommodate private / confidential meetings. The prominance of the room will require upgraded finishes.
Provide dimmable lighting controls and room darkening along all glass walls
Space Type: Office and Support
Space Type: Reception / Waiting SF: 370 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser Panic Button tied into building security
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors Electrical Raceway
Frames: AV Display / Control
Windows: Room Control
Glass Microphones
Card access suite access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1e
Reception / waiting should be located adjacent to conference room and direct access to suite entry.
Comfortable reception / waiting space provided for suite visitors prior to being escorted into suite.
A panic button is required at this location which is tied into building security.
Space Type: Office and Support
Space Type: Participant Day Lounge SF: 280 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Unit
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Aluminum frames with glass panel AV Display / Control
Windows: Room Control
Glass Aluminum framed with glass front along door wall Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1f
Participant day lounge should be located adjacent to patient rooms and in a secluded area near the nurse's station and coffee bar. Natural light is preferable.
Comfortable lounge space provided for participants exclusive use.
Space Type: Office and Support
Space Type: Equipment Storage SF: 190 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirrors
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets convenience
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1g
Equipment storage should be located in the inpatient area.
Open space intended to provide storage needs for miscellaneous equipment -hospital gurney, wheelchairs, rolling carts, etc.
Provide for flexibility of configuration management.
Space Type: Office and Support
Space Type: Medical Records SF: 350 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs File Cabinets
Other Chairs High Density Filing
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1h
Medical records should be located near the nurse's station and inpatient associated staff.
Medical records space provides secure location for sensitive patient records and miscellaneous filing.
High density filing requires enhanced floor live load (typical 250 psf) structure along with track recessed into the floor slab.
Space Type: Office and Support
Space Type: Staff Lounge SF: 180 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor ADA grab bars in single occupant toilet
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer ADA sink in single occupant toilet
Refrigerator plumbing connection Dishwasher
Microwave Oven counter mounted / ADA accessible ADA toilet in single occupant toilet
Recycling Containers Sink standard in counter
Water Dispenser Eye wash
Ice Machine plumbing for ice maker
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1i
Should be located near the inpatient area and preferrably with natural light.
Staff lounge for staff collaboration, refreshment or lunch. Atmosphere should be casual in style, collaborative in arrangement, spatially open but acoustically arranged to minimize disturbing noise from being transmitted to other areas.
Staff lounge should be configured for ADA accessibility.
Space should include an in-room single occupant toilet. Should have direct exhaust to ensure heat and odors do not migrate to adjacent spaces.
Space Type: Office and Support
Space Type: Staff Lounge SF: 140 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator plumbing connection Dishwasher
Microwave Oven counter mounted / ADA accessible Coffee Machine
Recycling Containers Sink standard in counter
Water Dispenser Eye wash
Ice Machine plumbing for ice maker
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1j
Should be located near the research office area and preferrably with natural light.
Staff lounge for staff collaboration, refreshment or lunch. Atmosphere should be casual in style, collaborative in arrangement, spatially open but acoustically arranged to minimize disturbing noise from being transmitted to other areas.
Staff lounge should be configured for ADA accessibility.
This space should have direct exhaust to ensure heat and odors do not migrate to adjacent spaces.
Space Type: Office and Support
Space Type: Coffee Bar SF: 60 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator plumbing connection Dishwasher
Microwave Oven counter mounted / ADA accessible Coffee Machine with water source
Recycling Containers Sink standard in counter
Water Dispenser
Ice Machine plumbing for ice maker
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors Electrical Raceway
Frames: AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1k
Should be located adjacent to reception/waiting and inpatient area.
Open area coffee bar for participant and staff refreshment. Coffee bar should be configured for ADA accessibility.
Space Type: Office and Support
Space Type: IT Office SF: 220 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1m
Should be located adjacent to research offices with direct access to a data closet.
IT staff office furnished and appointed to accommodate various tech functions including the storage, repair, and updating of computers and computer related components.
Preferred space to be woithout natural light.
Space Type: Office and Support
Space Type: NIA Data Closet/LAN SF: 80 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Red Emergency Plug emergency powered receptacles
Cypher lock Wireless Access
Fire Rating Racks
Folding Wall
Special Plumbing, HVAC or Lighting:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1n
Should be located thru-out the space with one NIA data closet located in the IT Office.
To support miscellaneous storage and IT needs of NIA and CIT. See Appendix D for CIT requirements
Provide flexibility of configuration management. Two closets will be dedicated for NIA Data and two closetsw will be dedicated for CIT LAN.
Dedicated cooling will be required along with power and cooling on the emergency generator in (1) NIA data closet. (1) NIA data closet and (2) LAN closets wll require emergency power.
Special Considerations: (2) LAN closets: 2000 BTU/hr & 1.5 KW, (2) 20A 120V NEMA 5-20 recept. (1) NIA data closet: 2500 BTU/hr & 2 KW,
(2) 20A 120V NEMA recept. (1) NIA data closet: 25000BTU/hr & 15 KW, 20KVA UPS or multiple 3KVA rack mounted UPS.
Space Type: Office and Support
Space Type: Business Center SF: 300 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects Space Data 1o
Should be centrally located in the research offce area.
Space provided to support miscellaneous administrative needs.
Space Type: Office and Support
Space Type: Lactation Room SF: 80 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Desk and Work Surface Work Station
Credenza Work Carrel
Conference Table Tackable Surface
Counter Space Base cabinetry
Reception Desk Wall Cabinetry
White Board Projector
Flat Panel Display Projection Screen
Modular Tables Shelving
Unique Monitor Mail Provisions
Desk Chairs Lockers
Other Chairs Mirror
Soft Seating Wall Display
Laundry Cart Mobile Shelving Units
Equipment / Appliances
Copier / Printer Vending Machine
Refrigerator Dishwasher
Microwave Oven Coffee Machine
Recycling Containers Sink
Water Dispenser
Ice Machine
Architectural Requirements Power and Data
Floor 2x2 carpet tile Duplex Outlets
Base vinyl cove base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Microphones
Card access Video Conference
Cypher lock Wireless Access
Fire Rating
Folding Wall
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Should be located convenient to staff.
Space provided to support nursing mother's use.
Space Data 1p
Space Type: Clinical / Research
Space Type: Private Participant Rm SF: 270 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Hospital Bed with rolling side table Desk and Work Surface
Patient Room Recliner Work Station / Carrel
Lockable Wardrobe Tackable Surface
Counter Space Base cabinetry
Flat Panel Display Wall Cabinetry
Soft Seating Desk Chairs
Modular Tables Slhelving
Exam Table ADA Grab Bars in ADA accessible bathroom
Crash Cart Work Bench
Mobile Cart Privacy Curtain
Treatment Recliner Blanket Warmer
Roller Stools Mobile Shelving Unit
Procedure Table Laundry Cart
Equipment / Appliances
Copier / Printer Ice Machine
Refrigerator ADA Toilet in ADA accessible bathroom
Freezer ADA Shower in ADA accessible bathroom
Oxygen & Suction ADA Sink in ADA accessible bathroom
Fume Hood Surgical Sink
Microwave Eye Wash
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 4'-0" Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Overhead Bed Light
Glass Microphones
Card access Nurse Call
Cypher lock Wireless Access
Fire Rating
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Should be located in a private area adjacent to the nurse's station and requires natural light.
Comfortable, relaxing and private space provided for participants staying over-night.
Space Data 2
Space should include an in-room, ADA accessible bathroom with nurse call. Bathroom requires direct exhaust to ensure heat and odors do not
Space Type: Clinical / Research
Space Type: Semi-Private Part Rm SF: 500, 270 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Hospital Bed with rolling side table Desk and Work Surface
Patient Room Recliner Work Station / Carrel
Lockable Wardrobe Tackable Surface
Counter Space Base cabinetry
Flat Panel Display Wall Cabinetry
Soft Seating Desk Chairs
Modular Tables Slhelving
Exam Table ADA Grab Bars in ADA accessible bathroom
Crash Cart Work Bench
Mobile Cart Privacy Curtain
Treatment Recliner Blanket Warmer
Roller Stools Mobile Shelving Unit
Procedure Table Laundry Cart
Equipment / Appliances
Copier / Printer Ice Machine
Refrigerator ADA Toilet in ADA accessible bathroom
Freezer ADA Shower in ADA accessible bathroom
Oxygen & Suction ADA Sink in ADA accessible bathroom
Fume Hood Surgical Sink
Microwave Eye Wash
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 4'-0" Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Overhead Bed Light
Glass Microphones
Card access Nurse Call
Cypher lock Wireless Access
Fire Rating
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Should be located in a private area adjacent to the nurse's station and requires natural light.
Comfortable, relaxing and private space provided for participants staying over-night.
Space should include an in-room, ADA accessible bathroom with nurse call. Bathroom requires direct exhaust to ensure heat and odors do not
Space Data 2a
Space Type: Clinical / Research
Space Type: Clamp Room SF: 500 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Hospital Bed with rolling side table Desk and Work Surface
Patient Room Recliner Work Station / Carrel
Lockable Wardrobe Tackable Surface
Counter Space Base cabinetry
Flat Panel Display Wall Cabinetry
Soft Seating Desk Chairs
Modular Tables File Cabinet
Exam Table White Board
Crash Cart ADA Grab Bars in ADA accessible bathroom
Mobile Cart Privacy Curtain
Treatment Recliner Blanket Warmer
Roller Stools Mobile Shelving Unit
Procedure Table Laundry Cart
Equipment / Appliances
Copier / Printer Ice Machine
Refrigerator Centrifuge
Freezer undercounter -20 Testing Equipment refer to equipment list
ADA Shower in ADA accessible bathroom Sink
ADA Toilet in ADA accessible bathroom Surgical Sink
ADA Sink in ADA accessible bathroom Eye Wash
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 4' x 0' Wood Task Lighting
Frames: Hollow Metal AV Display / Control
Windows: Overhead Bed Light
Glass Red Emergency Plug Emergency powered receptacle
Card access Nurse Call
Cypher lock Wireless Access
Fire Rating
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Should be located adjacent to the nurse's station near inparticipant rooms.
Clinical space furnished and appointed to accommodate testing procedures.
Space should include an ADA accessible toilet. Bathroom requires exhaust to ensure odors do not migrate to adjacent spaces.
Space Data 2b
Space Type: Clinical / Research
Space Type: Nourishment SF: 35 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Hospital Bed with rolling side table Desk and Work Surface
Patient Room Recliner Work Station / Carrel
Lockable Wardrobe Tackable Surface
Counter Space Base cabinetry
Flat Panel Display Wall Cabinetry
Soft Seating Desk Chairs
Modular Tables File Cabinet
Exam Table White Board
Crash Cart Work Bench
Mobile Cart Privacy Curtain
Treatment Recliner Blanket Warmer
Roller Stools Mobile Shelving Unit
Procedure Table Laundry Cart
Equipment / Appliances
Copier / Printer Ice Machine plumbing connection
Refrigerator undercounter Centrifuge
Freezer Testing Equipment
Oxygen & Suction Sink
Fume Hood Surgical Sink
Microwave Eye Wash
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors Task Lighting under cabinet
Frames: AV Display / Control
Windows: Room Control
Glass Red Emergency Plug
Card access Nurse Call
Cypher lock Wireless Access
Fire Rating
Special Plumbing, HVAC or Lighting: Other Special Considerations:
NIH Division of Planning
RMF Engineers, Inc. I Gaudreau, Inc. Architects
Should be located adjacent to the nurse's station near inparticipant rooms.
Easily accessible niche to provide nourishment for overnight participants.
Ice machine requires drain, cold water, and filter for ice.
Space Data 2c
Space Type: Clinical / Research
Space Type: Housekeeping Closet SF: 40 Adjacencies
Occupancy: Business
Space Description Comment:
Major Furnishing
Hospital Bed with rolling side table Desk and Work Surface
Patient Room Recliner Work Station / Carrel
Lockable Wardrobe Tackable Surface
Counter Space Base cabinetry
Flat Panel Display Wall Cabinetry
Soft Seating Desk Chairs
Modular Tables File Cabinet
Exam Table Shelving / Hooks
Crash Cart Work Bench
Mobile Cart Privacy Curtain
Treatment Recliner Blanket Warmer
Roller Stools Mobile Shelving Unit
Procedure Table Laundry Cart
Equipment / Appliances
Copier / Printer Ice Machine
Refrigerator Centrifuge
Freezer Testing Equipment
Oxygen & Suction Sink Janitor sink w/drain on floor
Fume Hood Surgical Sink
Microwave Eye Wash
Architectural Requirements Power and Data
Floor seamless vinyl flooring Duplex Outlets GFI req'd within 6' of sink
Base integral coved base Data Ports
Walls GWB, painted USB Ports
Ceiling ACT, 2x2 Floor Box
Ceiling Height 9'-0" min. Ceiling Mtd
Doors 3'-7' Wood Electrical Raceway
Frames: Hollow Metal AV Display / Control
Windows: Room Control
Glass Red Emergency Plug
Card access Nurse Call
Cypher lock Wireless Access
F…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .