This pre-solicitation notice and related solicitation document outline requirements for an indefinite-delivery/indefinite-quantity multiple award construction contract for fire protection projects. The Naval Facilities Engineering Command Southeast seeks to award approximately five design-build and design-bid-build IDIQ contracts for fire protection construction and repair services, including design. Services include fire suppression, water supply, foam, gaseous agent, alarm, and life safety systems. The total value of all contracts is $99 million over five years. Task orders will typically range from $150,000 to $9 million. Offerors must submit experience on a minimum of three and maximum of five relevant projects. The two-phase solicitation process will select proposals providing the best value, with the highest rated offeror receiving the initial task order. The pre-solicitation notice states that the solicitation will be available on FedBizOpps 15 days after posting. Phase one proposals will be due no less than 30 days after solicitation release.
N6945018R0502-0002.pdf
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N6945018R0502-0003.pdf | ||
| N6945018R0502-0001.pdf | ||
| N6945018R0502.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this amendment is to extend the proposal due date and provide revisions to Factor 2-Experience.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 27-Jul-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6945018R0502
X 9B. DATED (SEE ITEM 11)
14-Jun-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
27-Jul-2018
CODE
NAVFAC SOUTHEAST
ACQUISITION CORE
BLDG 903, PO BOX 30
NAS JACKSONVILLE
JACKSONVILLE FL 32212-0030
N69450 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N6945018R0502
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
AMENDMENT 0002
1) The proposal due date is changed to Tuesday 14 August 2018 NLT 3:00 PM ET.
2) Section 00150 III.F.3. (b) Non/Cost Price Factors is revised as follows (changes are in bold):
DELETE:
Provide one (1) original, four (4) copies and one (1) electronic copy (CD format) of the solicitation submittal requirements identified below.
REPLACE WITH:
Provide one (1) original, one (1) copy and one (1) electronic copy (CD format) of the solicitation submittal requirements identified below.
3) Section00150 III.F.3. (b) (2) (i) Solicitation Submittal Requirements to revise as follows (changes are in blue):
DELETE:
(1) Construction and Design Experience:
Submit a minimum of three (3) and a maximum of five (5) relevant design-build projects.
DEFINITION OF A RELEVANT PROJECT: Projects must have been completed by the offeror as the prime contractor in which the offeror’ s firm has self-performed the fire protection system installation efforts or prime subcontractor in which the offerors firm has self-performed the fire protection system installation efforts within the last seven (7) years from the date of the RFP. All projects must have a minimum fire protection construction cost of $750,000 and the fire protection construction cost shall be clearly indicated.
To be considered relevant each project shall be either new construction or renovation project which includes design and installation of at least two of the following fire protection systems: 1. Fire Suppression System (automatic sprinklers, gaseous or foam systems); 2. Fire Alarm Systems (fire detection system, fire notification systems, fire reporting systems, or mass notification systems); 3. Fire Water Supply Systems (fire mains, tanks or fire pumps).
Design and installation for each relevant project shall include; survey of existing conditions, layout and design, calculations, drawing and product data submittals, installation, and commissioning.
Projects must indicate fire protection scope of work was self-performed by offeror, work that was Sub- Contracted out will not be considered.
Experience in multiple project types may be considered a benefit to the Government and offerors may be rated higher.
If the Offeror is a Joint Venture (JV), relevant project experience should be submitted for projects completed by the Joint Venture entity. If the Joint Venture does not have shared experience, each member of the Joint Venture must submit at least one relevant project where they were the prime contractor or subcontractor. If each member of the JV does not have at least one relevant project, then the offeror will be considered unacceptable. Offerors are still limited to a total of five (5) projects combined.
If an Offeror is utilizing experience information of affiliates/subsidiaries/parent/LLC/LTD member companies (name is not exactly as stated on the SF1442), the proposal shall clearly demonstrate that the affiliate/subsidiary/parent firm will have meaningful involvement in the performance of the contract.
Only individual task orders issued against an IDIQ contract will be considered, we will not consider an IDIQ contract as a whole.
The attached Construction & Design Experience Project Data Sheet (Exhibit A) is MANDATORY and SHALL be used to submit project information.
The Offeror MAY NOT utilize experience of a subcontractor to demonstrate fire protection construction & design experience under this evaluation factor.
(1) Key Personnel
Submit resume(s) of the following team member(s). Resumes shall include professional licenses and certifications, number of years of experience, firms they have worked for, a list of relevant projects that they have completed, and their role on these projects. Resumes for each individual shall be limited to one double sided page or two single sided pages in length. (Note: Do NOT submit resumes of more than two pages in length; only the first two pages will be evaluated if more than two pages are submitted):
(1) Project Fire Protection Engineer - Must be registered professional engineer (FPE-PE) who has passed the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES) and with demonstrated experience on at least five
(5) fire protection-specific projects. Must have at least five (5) years of fire protection design experience since becoming registered as a licensed fire protection engineer and completion of the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES).
REPLACE WITH:
(1) Construction and Design Experience:
Submit a minimum of three (3) and a maximum of five (5) relevant design-build projects.
DEFINITION OF A RELEVANT PROJECT: Relevant projects must have been self-performed by the offeror (either as prime contractor or as subcontractor) within the last seven (7) years from the date of this RFP.
Self-performed means that the offeror conducted both the National Institute for Certification in Engineering Technology (NICET) design and installation of the fire protection system. Relevant projects shall be either new construction or renovation work, and must have a minimum fire protection cost of $750,000. The fire protection cost must be clearly indicated in the proposal. In addition, each relevant project must include at least two of the following fire protection systems: 1. Fire Suppression System (automatic sprinklers, gaseous or foam systems); 2. Fire Alarm Systems (fire detection system, fire notification systems, fire reporting systems, or mass notification systems); 3. Fire Water Supply Systems (fire mains, tanks or fire pumps).
NICET shop drawing package design and system installation for each relevant project shall include; survey of existing conditions, layout and design, calculations, drawing and product data submittals, installation, and commissioning.
Projects must indicate fire protection scope of work was self-performed by offeror, work that was Sub- Contracted out will not be considered.
If the Offeror is a Joint Venture (JV), relevant project experience should be submitted for projects completed by the Joint Venture entity. If the Joint Venture does not have shared experience, each member of the Joint Venture must submit at least one relevant project where they were the prime contractor or subcontractor. If each member of the JV does not have at least one relevant project, then the offeror will be considered unacceptable. Offerors are still limited to a total of five (5) projects combined.
If an Offeror is utilizing experience information of affiliates/subsidiaries/parent/LLC/LTD member companies (name is not exactly as stated on the SF1442), the proposal shall clearly demonstrate that the affiliate/subsidiary/parent firm will have meaningful involvement in the performance of the contract.
Only individual task orders issued against an IDIQ contract will be considered, we will not consider an IDIQ contract as a whole.
The attached Fire Protection Construction & Design Experience Project Data Sheet (Exhibit A) is MANDATORY and SHALL be used to submit project information.
The Offeror MAY NOT utilize experience of a subcontractor to demonstrate fire protection construction & design experience under this evaluation factor.
(2) Key Personnel
Submit resume(s) of the following team member(s). Resumes shall include professional licenses and certifications, number of years of experience, firms they have worked for, a list of relevant projects (minimum three (3) and maximum five (5) that they have completed, and their role on these projects. Resumes for each individual shall be limited to one double sided page or two single sided pages in length. (Note: Do NOT submit resumes of more than two pages in length; only the first two pages will be evaluated if more than two pages are submitted):
(1) Project Fire Protection Engineer - Must be registered professional engineer (FPE-PE) who has passed the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES) and with demonstrated experience on at least five
(5) fire protection-specific projects. Must have at least five (5) years of fire protection design experience since becoming registered as a licensed fire protection engineer and completion of the fire protection engineering written examination administered by the National Council of Examiners for Engineering and Surveys (NCEES).
(2) NICET Level IV Sprinkler Designer – Must be a National Institute for Certification in Engineering
Technology Level IV fire suppression certified, provide NICET Level IV certification number in resume. Must have at least fire (5) years of fire suppression system design experience since becoming NICET Level IV certified.
(3) NICET Level IV Fire Alarm Designer – Must be a National Institute for Certification in Engineering
Technology Level IV fire alarm certified, provide NICET Level IV certification number in resume.
Must have at least fire (5) years of fire alarm system design experience since becoming NICET Level IV certified.
All other terms and conditions remain unchanged.
SECTION 00010 - SOLICITATION CONTRACT FORM
The required response date/time has changed from 17-Jul-2018 03:00 PM to 14-Aug-2018 03:00 PM.
The number of offeror copies required has decreased by 3 from 4 to 1.
(End of Summary of Changes)