| N68335-12-R-0112 ATTACHMENT 008 RTCASS FRACAS REPORT | ||||||
| Customer | Date Created | Boeing PN | Item Name | Turn In Fail Description | Received Date (Boeing) | |
| Non-Fleet | 10-Dec-08 | 3841AS1880-01 | Rubidium | Unit fault lite is on - fault is killing entire 2A1 buss. | ||
| Non-Fleet | 10-Dec-08 | 3841AS2010-01 | Signal Generator | 10MHz Ref output of RFSG#00 not functioning. | 13-Sep-09 | |
| Non-Fleet | 18-Dec-08 | 3841AS1610-01 | 32VDC Power Supply | 0-32 VDC power supply failed to initialize at power up. | 11-May-09 | |
| Non-Fleet | 18-Dec-08 | 3841AS1610-02 | 100VDC Power Supply | 0-100 VDC power supply failed to initialize at power up. | 11-May-09 | |
| Non-Fleet | 18-Dec-08 | 3841AS1610-01 | 32VDC Power Supply | 0-32 VDC power supply failed to initialize at power up. | 11-May-09 | |
| Non-Fleet | 08-Jan-09 | 3841AS1610-03 | 450VDC Power Supply | 450 VDC power supply failed to initiatize at power up. | 11-May-09 | |
| Non-Fleet | 09-Jan-09 | 3841AS1610-02 | 100VDC Power Supply | 0-100 VDC power supply failed to initialize at power up. | 18-May-09 | |
| Non-Fleet | 20-Jan-09 | 3841AS1880-01 | Rubidium | Failed STRG SMAT test 2830, PCOF=2A1A11 & 2A1A12. | 26-Jan-09 | |
| Non-Fleet | 21-Jan-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | EPO: ACPSHV: ACPS event detected: Emergency Shutdown SRQ2 - DC Error on Channel: 1 - location 2A5PSI. | 10-Jul-09 | |
| Non-Fleet | 27-Jan-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Power Supply causes RT CASS Bench to fail Calibration test number 5053. | 11-May-09 | |
| Non-Fleet | 28-Jan-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | During CAL, Error Boxes caused CAL to halt,. | 11-May-09 | |
| Non-Fleet | 09-Feb-09 | 3841AS1830-01 | Pulse Generator | PGEN fails to initiatize. | 09-Feb-09 | |
| Non-Fleet | 12-Feb-09 | 3841AS1610-03 | 450VDC Power Supply | Power Supply caused emergency sense condition. | 11-May-09 | |
| Non-Fleet | 17-Feb-09 | 3841AS1830-01 | Pulse Generator | STRG failed background IST. | 23-Feb-09 | |
| Non-Fleet | 17-Feb-09 | 3841AS1580-01 | Waveform Digitizer | WFRD failed SMAT test 4405. | 25-Feb-09 | |
| Non-Fleet | 19-Feb-09 | 3841AS1231-01 | CASS to M9 CRB | DTI CRB fails Calibration and RTSMAT. | 18-Feb-09 | |
| Non-Fleet | 19-Feb-09 | 3841AS1230-01 | Digital CRB (DTI) | Fails RTSMATIO test 2448. At OEM Fail burst, CPP, Window and phase | 20-Mar-09 | |
| Non-Fleet | 20-Feb-09 | 3841AS1610-01 | 32VDC Power Supply | Power Supply causes IEHMERR (Yellow screen message) on RT Launch which shuts down RT. | 11-May-09 | |
| Non-Fleet | 20-Feb-09 | 3841AS1610-01 | 32VDC Power Supply | Power Supply causes IEHMERR (Yellow screen message) on RT Launch which shuts down RT. | 11-May-09 | |
| Non-Fleet | 20-Feb-09 | 3841AS1610-01 | 32VDC Power Supply | Power Supply causes IEHMERR (Yellow screen message) on RT Launch which shuts down RT. | 11-May-09 | |
| Non-Fleet | 23-Feb-09 | 3841AS1231-01 | CASS to M9 CRB | DTI CRB fails Calibration and RTSMAT. | 18-Feb-09 | |
| Non-Fleet | 23-Feb-09 | 3841AS1880-01 | Rubidium | Fails to initialize. | 23-Feb-09 | |
| Non-Fleet | 02-Mar-09 | 3841AS2010-02 | Signal Generator | RFSG # 2 fail IST. | 10-Mar-09 | |
| Non-Fleet | 16-Mar-09 | 3841AS1230-01 | Digital CRB (DTI) | Intermittant channel operation on J2B and J3B. Fails channels 36-39;44-47 | 10-Jul-09 | |
| Non-Fleet | 26-Mar-09 | 3841AS1230-01 | Digital CRB (DTI) | CCA will not initialize. | 10-Jul-09 | |
| Non-Fleet | 26-Mar-09 | 3841AS1230-01 | Digital CRB (DTI) | Hard failures during SMAT. At OEM fails channels 28,29,30 and burst | 10-Jul-09 | |
| Non-Fleet | 30-Mar-09 | 3841AS1610-01 | 32VDC Power Supply | Power Supply causes IEHMERR (Yellow screen message) on RT Launch which shuts down RT. | 03-Apr-09 | |
| Non-Fleet | 30-Mar-09 | 3841AS1840-01 | Multimeter, Digital, VXI | DMM fails SMAT and CAL. | 03-Apr-09 | |
| Non-Fleet | 07-Apr-09 | 3841AS1314-01 | VT-6000-RT Switch Module | Caused GPIB relay failure slot J6 1A2A1 during ULAS testing. | 08-May-09 | |
| Non-Fleet | 07-Apr-09 | 3841AS1240-01 | Central Resource Board (CRB) | 1A1A10 fails IST, fails SMAT TN1080,.022, fails M9 selftest.exe - A for SR_REF and SR_Loopback for slot 10. | 18-May-09 | |
| Non-Fleet | 09-Apr-09 | 3841AS2010-01 | Signal Generator | RFSG # 00 will report selftest error EC: -79991000 during power up SMAT test step 1080.46 fails (MV=N/A UL=N/A LL=N/A). | 25-Aug-09 | |
| Non-Fleet | 28-Apr-09 | 3841AS1860-01 | SGMA (Teradyne claims Rubidium 05020208 received on this RMA) | SGMA fails IST, SMAT and CAL. | 28-Apr-09 | |
| Non-Fleet | 28-Apr-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | 1 - 135 VAC Power Supply fails SMAT and CAL. | 29-Apr-09 | |
| Non-Fleet | 26-May-09 | 3841AS1230-01 | Digital CRB (DTI) | Causes "overflow stack" and TS11, TS12, TS13 and output status light on PS1 to not come on. | 10-Jul-09 | |
| Non-Fleet | 08-Jun-09 | 3841AS1830-01 | Pulse Generator | STRG/PGEN fails to initialize. | 09-Jun-09 | |
| Non-Fleet | 08-Jun-09 | 3841AS1880-01 | Rubidium | RBCLK fails to initialize. | 09-Jun-09 | |
| Non-Fleet | 10-Jun-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | 2A5PS1 - Error on station power up - Instrument power down - EPO: ACPS Event Detected ! Emergency Shutdown SRQ.2 0X0000002 - DC Error on channel 1. | 10-Jul-09 | |
| Non-Fleet | 11-Jun-09 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA fails IST. | 02-Jun-09 | |
| Non-Fleet | 15-Jun-09 | 3841AS1231-01 | CASS to M9 CRB | Fails DTI confidence test. | 06-Jul-09 | |
| USAF | 16-Jun-09 | 3841AS2010-01 | Signal Generator | RFSG # 2, Self test error, EC: - 79991000, Self test failed. | 06-Jul-09 | |
| USAF | 16-Jun-09 | 3841AS2115-02 | Down Converter | Broken trigger-in connector. | 30-Jun-09 | |
| Non-Fleet | 17-Jun-09 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA 1A1A3 received bad from supply, CCA does not initialize. | 06-Jul-09 | |
| Non-Fleet | 22-Jun-09 | 3841AS1580-01 | Waveform Digitizer | WFRD fails SMAT, T4180 & T4185, channel B 50 ohm. | 30-Jun-09 | |
| Non-Fleet | 23-Jun-09 | 3841AS1580-01 | Waveform Digitizer | WFRD fails calibration. | 30-Jun-09 | |
| Non-Fleet | 29-Jun-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Unit failed, suspect soft start circuitry. | 10-Jul-09 | |
| Non-Fleet | 30-Jun-09 | 3841AS1240-01 | Central Resource Board (CRB) | Received to fill OC06 requirement but received bad. Fails M9 self test. Missing Screw At Front panel. | 18-May-09 | |
| Non-Fleet | 30-Jun-09 | 3841AS1840-01 | Multimeter, Digital, VXI | Attempted to reset DMM, failed to communicate. Powered down and reseated DMM, still fails to communicate. | 21-Sep-09 | |
| Non-Fleet | 30-Jun-09 | 3841AS1230-01 | Digital CRB (DTI) | DTI card fails SMAT. | 25-Aug-09 | |
| Non-Fleet | 30-Jun-09 | 3841AS1610-03 | 450VDC Power Supply | Calibration failure: DCPSCO FTN4586 MV 0.5436 ADC UL 0.4 LL 0.2, PCOF 1A5PS6. SMAT Passes. | 08-Jul-09 | |
| Non-Fleet | 08-Jul-09 | 3841AS1580-01 | Waveform Digitizer | Fails CALIBRATION. | 18-Jul-09 | |
| Non-Fleet | 08-Jul-09 | 3841AS1580-01 | Waveform Digitizer | Fails CALIBRATION. | 05-Aug-09 | |
| USAF | 09-Jul-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | 2A5PS1 - Error on station power up - Instrument power down - EPO: ACPS Event Detected ! Emergency Shutdown SRQ.2 0X0000002 - DC Error on channel 1. Reports under voltage during power up and an emergency shutdown of all instrument power occurs. | 12-Aug-09 | |
| Non-Fleet | 10-Jul-09 | 3841AS1580-01 | Waveform Digitizer | WFRD failure during SMAT: test 1480 MV 44.8 ohm ADC UL 55 ohm LL 45 ohm. | 05-Aug-09 | |
| Non-Fleet | 14-Jul-09 | 3841AS1580-01 | Waveform Digitizer | Intermittent failure during WFRD CAL. In the process of running WFRD CAL, the WFRD took longer than expected (6 minutes, per the CAL test program) to complete Self-Cal. As a result, CAL failed. Re-ran, this time manually awaiting self-cal completio | 12-Sep-09 | |
| Non-Fleet | 14-Jul-09 | 3841AS1610-01 | 32VDC Power Supply | Asset failed power up. | 04-Aug-09 | |
| USAF | 14-Jul-09 | 3841AS1610-01 | 32VDC Power Supply | 1A5PS2 32VDC power supply fails IST during OSV. | 04-Aug-09 | |
| USAF | 20-Jul-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | AC power supply 2A5PS3 reports under voltage during power up and an emergency shutdown of all instrument power occurs. | 04-Aug-09 | |
| Non-Fleet | 27-Jul-09 | 3841AS1860-01 | SGMA | Fails IST. | 07-Aug-09 | |
| Non-Fleet | 29-Jul-09 | 3841AS1580-01 | Waveform Digitizer | Fails Calibration CH B. | 31-Aug-09 | |
| Non-Fleet | 29-Jul-09 | 3841AS1315-01 | VT-5000-RT Switch Module | 1A2A4 Fails INIT. | 19-Aug-09 | |
| Non-Fleet | 29-Jul-09 | 3841AS1230-01 | Digital CRB (DTI) | Fails IST & SMAT Test Group 03. | 31-Aug-09 | |
| Non-Fleet | 29-Jul-09 | 3841AS1830-01 | Pulse Generator | Fails IST & SMAT. | 31-Aug-09 | |
| Non-Fleet | 31-Jul-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | AC power supply fails to power up. Subject supply went bad in UAA008, pulled one out of UAA007. ETI applies to the power supply that came out of UAA008. | 03-Aug-09 | |
| Non-Fleet | 03-Aug-09 | 3841AS1811-01 | Chassis Assembly, VXI, Low Pwr, Opt A | Causes backplane to hang up. | 10-Aug-09 | |
| Non-Fleet | 03-Aug-09 | 3841AS1830-01 | Pulse Generator | Problem Desc: fails SMAT CAL 12, reported 5 returned 10 | 04-Aug-09 | |
| Non-Fleet | 04-Aug-09 | 3841AS1230-01 | Digital CRB (DTI) | Causes DTI initialization and IST failures for DTI #07. | 31-Aug-09 | |
| Non-Fleet | 11-Aug-09 | 3841AS1830-01 | Pulse Generator | Fails to initialize during power up. | 31-Aug-09 | |
| Non-Fleet | 12-Aug-09 | 3841AS2010-01 | Signal Generator | Fails to initialize during power up. | 31-Aug-09 | |
| Non-Fleet | 12-Aug-09 | 3841AS1860-01 | SGMA | 2A1A3 - Unit contiuously fails IST. Alignment also failed - fault light on. | 12-Sep-09 | |
| Non-Fleet | 13-Aug-09 | 3841AS1860-01 | SGMA | Fails station initialization, IST & Calibration. | 31-Aug-09 | |
| Non-Fleet | 14-Aug-09 | 3841AS1880-01 | Rubidium | 2A1A12 - Trigger Board Failure. | 24-Sep-09 | |
| Non-Fleet | 17-Aug-09 | 3841AS1610-01 | 32VDC Power Supply | Fails Calibration and TG04. | 31-Aug-09 | |
| Non-Fleet | 18-Aug-09 | 3841AS1880-01 | Rubidium | Fails to communicate, no clock to 1A3. | 31-Aug-09 | |
| Non-Fleet | 18-Aug-09 | 3841AS1860-01 | SGMA (Black Fin) | SGMA fails SMAT/Calibration and Field Calibration. Found a pulled pin on 1 A2W35 P35 and the SGMA J1 connection. Pulled pin has been fixed but the asset was still bad. | 15-Sep-09 | |
| Non-Fleet | 19-Aug-09 | 3841AS1240-01 | Central Resource Board (CRB) | DTI CRB fails SMAT user clock DSKEW. | 28-Aug-09 | |
| Non-Fleet | 25-Aug-09 | 3841AS1850-01 | Counter/Timer, VXI | FTIC Fails Cal TN2710, TN2712 intermittently. Always fails TN2728. | 28-Oct-09 | |
| Non-Fleet | 25-Aug-09 | 3841AS1230-01 | Digital CRB (DTI) | RTSMAT DTI Failure TN 2466. | 12-Sep-09 | |
| Non-Fleet | 26-Aug-09 | 3841AS1860-01 | SGMA | SGMA # 00 Fails IST, SMAT, and CAL. | 12-Sep-09 | |
| Non-Fleet | 26-Aug-09 | 3841AS1230-01 | Digital CRB (DTI) | Channel Card Fails IST and SMAT. SMAT failures at #2432 and #2541 for pins J13_17A, J13_18B. | 31-Aug-09 | |
| Non-Fleet | 26-Aug-09 | 3841AS1860-01 | SGMA (Black Fin) | Fails station IST. | 14-Sep-09 | |
| Non-Fleet | 04-Sep-09 | 3841AS1230-01 | Digital CRB (DTI) | Causes failure of DTI calibration Test# 5775. | 09-Sep-09 | |
| USAF | 11-Sep-09 | 3841AS1240-01 | Central Resource Board (CRB) | 1A1A10 Fails Digital Test # 2495 in both Test Stations (UAA082/UAA081). | 11-Sep-09 | |
| Non-Fleet | 14-Sep-09 | 3841AS1230-01 | Digital CRB (DTI) | SMAT Provided a PCOF of 1A1A3 channel card. | 25-Aug-09 | |
| Non-Fleet | 14-Sep-09 | 3841AS1230-01 | Digital CRB (DTI) | SMAT Provided a PCOF of 1A1A4 channel card. | 25-Aug-09 | |
| Non-Fleet | 14-Sep-09 | 3841AS1220-01 | Slot 0 Controller | Found bent pin on 1A1A0 slot ) controller card. | 25-Aug-09 | |
| Non-Fleet | 14-Sep-09 | 3841AS1610-01 | 32VDC Power Supply | Replaced 1A1A0 and Station shut down with a yellow screen. Troubleshooting procedures determined that a DCPS was not responding on the GPIB Communication Bus. | 25-Aug-09 | |
| Non-Fleet | 14-Sep-09 | 3841AS1314-01 | VT-6000-RT Switch Module | SMAT E-T-E failed test 1324 with a MV of 2.2VDC, UL .85, LL .545. PCOF provided was 1A2A1. | 28-Aug-09 | |
| Non-Fleet | 15-Sep-09 | 3841AS1220-01 | Slot 0 Controller | After powering up the station, the 1A1 would not report. It was determined that a pin at J1 was crushed. | 15-Sep-09 | |
| Non-Fleet | 15-Sep-09 | 3841AS1314-01 | VT-6000-RT Switch Module | OTPS 10 IDST Fails Test 1105, MV 170 Kohms, UL 205 Kohms, LL 194 Kohms. | 25-Sep-09 | |
| Non-Fleet | 18-Sep-09 | 3841AS1315-01 | VT-5000-RT Switch Module | Caused V22 OTPS001 test 4310 to fail, GPI passed IST and SMAT. Swapped with LFS out of UAA007 and test 4310 passed. | 29-Sep-09 | |
| Non-Fleet | 21-Sep-09 | 3841AS1860-01 | SGMA (Black Fin) | SGMA continuously fails IST. | 29-Sep-09 | |
| Non-Fleet | 22-Sep-09 | 3841AS1240-01 | Central Resource Board (CRB) | DTI CRB fails SMAT failed test 2494 and user clock DSKEW. | 22-Sep-09 | |
| Non-Fleet | 22-Sep-09 | 3841AS1610-01 | 32VDC Power Supply | Causes power up problems. | 28-Sep-09 | |
| Non-Fleet | 24-Sep-09 | 3841AS1830-01 | Pulse Generator | Will not initialize. | 20-Oct-09 | |
| Non-Fleet | 24-Sep-09 | 3841AS1880-01 | Rubidium | STRG fails RTSMAT test 5455 no signal. Rubidium Osc. Caused failure. | 25-Sep-09 | |
| Non-Fleet | 02-Oct-09 | 3841AS1860-01 | SGMA (Black Fin) | Fails to initialize during IST. | 02-Oct-09 | |
| Non-Fleet | 02-Oct-09 | 3841AS1850-01 | Counter/Timer, VXI | FTIC fails to calibrate. | 02-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS1230-01 | Digital CRB (DTI) | DTI fails SMAT. | 05-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS1880-01 | Rubidium | 100 MHz distribution Board is bad, INA and INB ECL Ports bad. | 05-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS1890-01 | Arbitrary Waveform Generator | ECL Output stuck in Channel 1 Dig Out Pins 8 & 23. | 05-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS2010-01 | Signal Generator | FAILED TEST 1080.047 UNIT RFSG # 1 Probable cause of failure 2A3A2 SMAT Entry Pt. 14 Test # 7815 MV = 0.0000MHZ Probable cause of failure 2A3A2. | 08-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS1880-01 | Rubidium | Replaced Rub. Osc. , it lasted approximately 3 days and failed; will not initialize, R&R'd again with one out of UAA008 on 2 Oct. and it is still working. Please initiate a request for document UAA007 9278 CH54. | 05-Oct-09 | |
| Non-Fleet | 05-Oct-09 | 3841AS1830-01 | Pulse Generator | STRG fails to Cal. Please initiate a request for document UAA050 9282 JA23. | 05-Oct-09 | |
| Non-Fleet | 07-Oct-09 | 3841AS2010-01 | Signal Generator | Fails SMAT / IST. | 28-Oct-09 | |
| Non-Fleet | 08-Oct-09 | 3841AS1811-01 | Chassis Assembly, VXI, Low Pwr, Opt A | TS22 was reported as being over temp and shut the station down. | 08-Oct-09 | |
| Non-Fleet | 08-Oct-09 | 3841AS1830-01 | Pulse Generator | The STRG will not initialize. | 13-Oct-09 | |
| Non-Fleet | 13-Oct-09 | 3841AS1240-01 | Central Resource Board (CRB) | Fails Calibration. | 13-Oct-09 | |
| Non-Fleet | 20-Oct-09 | 3841AS1840-01 | Multimeter, Digital, VXI | Fails Calibration Test # 2310, reads open, intermittent. | 20-Oct-09 | |
| Non-Fleet | 22-Oct-09 | 3841AS1730-01 | DCPS Isolation Assy | While running SMAT, test 3316 failed. MV: 99.996 VDC UL: 5 LL: N/A with a PCOF of 1A5A1, 2A2A1A13. Loaded R43 to see if the failure still occurred. It did but with a different diagnostic procedure and a PCOF of only the 1A5A1. The 1A5A1 was removed and i | 23-Oct-09 | |
| Non-Fleet | 22-Oct-09 | 3841AS2115-03 | Spectrum Analyzer / RF Pwr Meter | Fails Calibration TG14, communication reset error, hangs up station. | 23-Oct-09 | |
| Non-Fleet | 04-Nov-09 | 3841AS1850-01 | Counter/Timer, VXI | Fails hysteresis at 100-120 Mhz for both channels and appears to have the wrong firmware load. | 09-Nov-09 | |
| Non-Fleet | 04-Nov-09 | 3841AS1580-01 | Waveform Digitizer | Failing Ch A input impedence verification for 50-ohms and channel B has excessive noise of the magnitude of 4mV. | 04-Nov-09 | |
| Non-Fleet | 04-Nov-09 | 3841AS1850-01 | Counter/Timer, VXI | Fails channel B/2 100Mhz frequency check. | 04-Nov-09 | |
| Non-Fleet | 06-Nov-09 | 3841AS1850-01 | Counter/Timer, VXI | Fails Calibration test 2720. | 13-Nov-09 | |
| Non-Fleet | 06-Nov-09 | 3841AS1850-01 | Counter/Timer, VXI | Fails Calibration test 2728. | 09-Nov-09 | |
| Fleet | 10-Aug-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 07-Aug-09 | |
| Fleet | 26-Aug-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 25-Aug-09 | |
| Fleet | 18-Nov-09 | 3841AS1830-01 | Pulse Generator | CND | 28-Oct-09 | |
| Fleet | 16-Oct-09 | 3841AS1840-01 | Multimeter, Digital, VXI | DMM FAILS SELFTEST CAUSING BENCH TO BE INOP. POC SGT MCARDLE EXT. 6267 | 16-Oct-09 | |
| Fleet | 03-Nov-09 | 3841AS1840-01 | Multimeter, Digital, VXI | DMM fails self-test making bench inop | 03-Nov-09 | |
| Fleet | 18-Nov-09 | 3841AS2115-02 | Down Converter | Instrument failed calibration for frequency response with approximately -8dB power hole at frequency around 24Ghz | 12-Nov-09 | |
| Fleet | 26-Aug-09 | 3841AS1580-01 | Waveform Digitizer | FLEET DATA NEEDED | 25-Aug-09 | |
| Fleet | 31-Jul-09 | 3841AS1860-01 | SGMA (Black Fin) | VERIFIED BAD DURING INITIAL POWER UP PROCEDURES. | 22-Jul-09 | |
| Fleet | 09-Sep-09 | 3841AS1860-01 | SGMA (Black Fin) | FLEET DATA NEEDED | 25-Aug-09 | |
| Fleet | 31-Jul-09 | 3841AS1610-03 | 450VDC Power Supply | 450 VOLT POWER SUPPLY CAUSES BENCH TO SHUT DOWN BEFORE BOOT UP PROCESS IS COMPLETE. | 28-Jul-09 | |
| Fleet | 03-Nov-09 | 3841AS1610-01 | 32VDC Power Supply | DC POWER SUPPLY FAILED ON START UP DCPS OUTPUT VOLTAGE TOO LOW | 09-Nov-09 | |
| Fleet | 03-Nov-09 | 3841AS1610-01 | 32VDC Power Supply | FLEET DATA NEEDED | 09-Nov-09 | |
| Fleet | 26-Aug-09 | 3841AS1315-01 | VT-5000-RT Switch Module | FAILS SMAT Test #1122. Diagnostic test # 8008. | 07-Aug-09 | |
| Fleet | 16-Oct-09 | 3841AS1536-01 | Relay Driver, SMP7500 | FLEET DATA NEEDED | 16-Oct-09 | |
| Fleet | 30-Oct-09 | 3841AS1880-01 | Rubidium | FLEET DATA NEEDED | 12-Nov-09 | |
| FLEET | 25-Sep-09 | 3841AS2310-01 | Computer | N/A | 24-Sep-09 | |
| Fleet | 03-Nov-09 | 3841AS1535-01 | RF Switch, SMP6101 | Switch assembly was found bad while troubleshooting. Verified bad | 03-Nov-09 | |
| Non-Fleet | 28-Apr-09 | 3841AS1314-01 | VT-6000-RT Switch Module | GPIB relay failure Slot J7 1A2A1 Occured during ULAS Testing of RT SMAT program | 08-May-09 | |
| Fleet | 28-Oct-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 01-Nov-09 | |
| Fleet | 30-Oct-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 30-Oct-09 | |
| Fleet | 02-Nov-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 10-Nov-09 | |
| Fleet | 12-Nov-09 | 3841AS1830-01 | Pulse Generator | Level error 50 ohm channel 2 | 10-Nov-09 | |
| Fleet | 12-Nov-09 | 3841AS1830-01 | Pulse Generator | FLEET DATA NEEDED | 10-Nov-09 | |
| Fleet | 28-Sep-09 | 3841AS2115-02 | Down Converter | SPEC AN CAUSES BENCH TO HAVE POWER UP FAILURES. | 28-Sep-09 | |
| Fleet | 28-Oct-09 | 3841AS2115-02 | Down Converter | Fault Details: 1). Instrument was received with the following parts missing: 2 LO cables (N8201-20120) and 50 ohm load (1810-0118) on instrument's front panel. | ||
| 2). Power on, instrument fails auto alignment for Preamp error (dead PA): New Preamp is requi | 28-Oct-09 | |||||
| Fleet | 15-Oct-09 | 3841AS1580-01 | Waveform Digitizer | Instrument fails power up procedure | 14-Oct-09 | |
| Fleet | 31-Jul-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Causes RTCASS bench to fail powerup | 28-Jul-09 | |
| Fleet | 26-Aug-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | AC POWER SUPPLY 2A5PS1 PREVENTS BENCH FROM POWERING UP PROPERLY | 25-Aug-09 | |
| Fleet | 06-Oct-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Fails self test | 05-Oct-09 | |
| Fleet | 15-Oct-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | ACPS2 CAUSES BENCH TO FAIL SELF-TEST | 13-Oct-09 | |
| Fleet | 16-Oct-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | POWER SUPPLY FAILS SELF TEST CAUSING BENCH DOWNTIME. | 16-Oct-09 | |
| Non-Fleet | 18-Nov-09 | 3841AS1850-01 | Counter/Timer, VXI | Fails calibration test # 2728. | 15-Jan-10 | |
| Non-Fleet | 19-Nov-09 | 3841AS2010-01 | Signal Generator | While station running backgroued IST, RFSG # 02 (2A5A1) failed, ran self test on RFSG # 02 and failed with an "EC" error. Cycled station power and re-ran test. Still fails. | 20-Nov-09 | |
| Non-Fleet | 04-Nov-09 | 3841AS2115-02 | Down Converter | Test 7852.008 failed. MV: -25.508 Dbm UL: -1.5 LL: -9.63. The test failed all 3 repeats. PCOF 2A4A1. The 2A4A1 was removed from UAA001 and installed into UAA002. RTSMAT passed all tests. | 02-Nov-09 | |
| Non-Fleet | 24-Nov-09 | 3841AS1610-03 | 450VDC Power Supply | Fails SMAT TEST # 3603, HWPL TEST. | 15-Jan-10 | |
| Non-Fleet | 30-Nov-09 | 3841AS1315-01 | VT-5000-RT Switch Module | GPIB Switch Card 1A2A4 relay failure due to excessive current. | 24-Nov-09 | |
| Non-Fleet | 02-Dec-09 | 3841AS2115-02 | Down Converter | SPECAN # 00 (DOWNCONVERTER) will not perform internal alignment. Specan # 00 initially failed to align and IST on 11/5/09 before station was powered down for extended time and failed again upon power up on 11/23/09. Failure is repeatable, SPECAN # 00 self | 02-Dec-09 | |
| Non-Fleet | 02-Dec-09 | 3841AS1880-01 | Rubidium | 2A1A12 FSD causes STRGCAL to fail test 3423.008 with a MV= 0.1E -38, UL= 0.106E -07, LL= 0.940E -08. | 02-Dec-09 | |
| Fleet | 23-Nov-09 | 3841AS1580-01 | Waveform Digitizer | WFRD fails calibration. Needs to be replaced. | 03-Dec-09 | |
| Fleet | 20-Nov-09 | 3841AS1860-01 | SGMA (Black Fin) | SGMA fails IST, SMAT | 08-Dec-09 | |
| Fleet | 16-Nov-09 | 3841AS2115-02 | Down Converter | SPECAN does not initialize | 08-Dec-09 | |
| Fleet | 03-Dec-09 | 3841AS2010-01 | Signal Generator | Fails to initialize during power up | 03-Dec-09 | |
| Fleet | 01-Dec-09 | 3841AS1830-01 | Pulse Generator | Fails to initialize and fails IST | 14-Dec-09 | |
| Fleet | 23-Nov-09 | 3841AS1230-01 | Digital CRB (DTI) | DTU CCA causes bench to have DTI failures | 23-Nov-09 | |
| Fleet | 23-Nov-09 | 3841AS1230-01 | Digital CRB (DTI) | DTU CCA causes bench to have DTI failures | 23-Nov-09 | |
| Non-Fleet | 17-Dec-09 | 3841AS1315-01 | VT-5000-RT Switch Module | OTPS # 5, UUT 450 fails test 700, NDX15 with MV 32 Ohms swapped 1A2A4 from sta 10 which allowed the test to pass with MV 0.9. Check of the path indicated 0.3 Ohms. | 09-Mar-10 | |
| Non-Fleet | 22-Dec-09 | 3841AS1860-01 | SGMA (Black Fin) | Unit Fails Instrument Self Test (IST) - CH3 RSL -90V L-L, Exp 0.00, Act 180.011. Field Cal did not correct this problem. | 29-Dec-09 | |
| USAF | 23-Dec-09 | 3841AS2360-01 | System Monitor CCA | ACPSPM # O fault causes station instrument power to shut down. Removed environmental monitor CCA. Causes same failure in second station. | 20-Jan-10 | |
| Non-Fleet | 04-Jan-10 | 3841AS1230-01 | Digital CRB (DTI) | Part received from supply, Installed in station UAA001. 1A1A7 would not pass IST. Removed part and installed in station UAA002. Still would not pass IST. | 08-Jan-10 | |
| Non-Fleet | 04-Jan-10 | 3841AS2010-01 | Signal Generator | Unit Fails Instrument Self Test (IST) | 13-Jan-10 | |
| USAF | 06-Jan-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI # 03 causes SMAT to fail TN 2558. | 10-Feb-10 | |
| Non-Fleet | 08-Jan-10 | 3841AS1880-01 | Rubidium | No output. | 12-Jan-10 | |
| Non-Fleet | 11-Jan-10 | 3841AS1610-02 | 100 VDC Power Supply | Came with station UAA031 and it has a broken "J2 AC IN" Connector. | 13-Jan-10 | |
| Fleet | 18-Dec-09 | 3841AS1230-01 | Digital CRB (DTI) | DTU CHANNEL CARD CAUSES BENCH TO HAVE DTI FAILURES. | 15-Dec-09 | |
| FLEET | 21-Jan-10 | 3841AS1231-01 | CASS to M9 CRB | V0911493485E01 - 1A1A10A1 VCID WILL NOT PASS SELF TEST | 17-Dec-09 | |
| Fleet | 21-Dec-09 | 3841AS1610-01 | 32VDC Power Supply | 32 VDC POWER SUPPLY CAUSES BENCH NOT TO POWER UP | 21-Dec-09 | |
| Fleet | 11-Jan-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Causes RTCASS failures | 11-Jan-10 | |
| Fleet | 11-Jan-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | ACPS CAUSES FAILURES IN RTCASS | 05-Jan-10 | |
| Non-Fleet | 19-Jan-10 | 3841AS1532-01 | Base Unit | Causes signature resistor errors and TG 1 failures. FAILS -2.2 V WILL NOT STAY ON | 16-Nov-09 | |
| Non-Fleet | 19-Jan-10 | 3841AS1230-01 | Digital CRB (DTI) | While running SMAT to verify new DTI functions properly, another DTI # 03 failed SMAT. The station was powered down to swap DTI # 03 with # 02. After power up, DTI # 02 would not pass IST. This was a DTI received in October and not tested until the 1A1 wa | 29-Jan-10 | |
| Non-Fleet | 20-Jan-10 | 3841AS1230-01 | Digital CRB (DTI) | 1/7/2010 Time: Installed replacement DTI channel card in the 1A1A3 slot and ran SMAT. Failed test 2524, PCOF of 1A1A3. Atempted calibration, failed. Moved suspect card to station UAA002, fails in the same manner. | 27-Jan-10 | |
| Non-Fleet | 22-Jan-10 | 3841AS2115-02 | Down Converter | 2A4A1 (Downconverter) SPECAN # 00 S/N US46400183 was received properly packaged 12/16/09, However when removing the asset from the sealed box it was noticed the two hard lines connected to the front of the asset, N8201-20128 Rev B, were bent inwards towar | 02-Feb-10 | |
| Non-Fleet | 09-Feb-10 | 3841AS1580-01 | Digitizer | WFRD fails CAL T/N 3016, MV 51.95 ohms. | 24-Feb-10 | |
| Non-Fleet | 09-Feb-10 | 3841AS1580-01 | Waveform Digitizer | WFRD fails CAL at TN 3326.006, DC offset at 200Mhz. Swapped CAL ID's, cleaned and checked all internal and external cables used. | 24-Feb-10 | |
| Non-Fleet | 10-Feb-10 | 3841AS1860-01 | SGMA | Fails to initialize. Verified SGMA all three input channels dead. | 11-Feb-10 | |
| Fleet | 27-Jan-10 | 3841AS2010-02 | Signal Generator | SYNTHESIZER FAILS TO COMMUNICATE WITH THE RTCASS BENCH. ANOTHER RF SYNTHESIZER WAS INSTALLED AND COMMUNICATED PERFECTLY. | 28-Jan-10 | |
| Fleet | 08-Feb-10 | 3841AS2010-01 | Signal Generator | CAUSES RT BENCH TO FAIL SELF MAINTENANCE | 09-Feb-10 | |
| Fleet | 14-Jan-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | AC PS HB02 Causes RTCASS to Fail | 14-Jan-10 | |
| Fleet | 28-Jan-10 | 3841AS1580-01 | Waveform Digitizer | WFRD FAILS DURING CASS TESTING | 28-Jan-10 | |
| Fleet | 14-Jan-10 | 3841AS1580-01 | Waveform Digitizer | CAUSES RTCASS TO FAIL SMAT AND CAL | 14-Jan-10 | |
| Fleet | 11-Jan-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA WILL NOT PASS SMAT | 14-Jan-10 | |
| Fleet | 28-Jan-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS ALIGNMENT AND INSTRUMENT SELF TEST | 28-Jan-10 | |
| Fleet | 22-Jan-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS SMAT/CALIBRATION PER 16-30USM702-2-1 | 25-Jan-10 | |
| Fleet | 14-Jan-10 | 3841AS1860-01 | SGMA (Black Fin) | SYNCHRO TEST SET FAILS | 15-Jan-10 | |
| Fleet | 04-Feb-10 | 3841AS1850-01 | Counter/Timer, VXI | FTIC CAUSES RTCASS ASSETS TO FAIL POWER UP | 07-Feb-10 | |
| Fleet | 21-Jan-10 | 3841AS1880-01 | Rubidium | WILL NOT OSCILLATE | 21-Jan-10 | |
| Fleet | 08-Feb-10 | 3841AS1830-01 | Pulse Generator | STRG IS VERIFIED BAD DURING TROUBLESHOOTING | 08-Feb-10 | |
| Non-Fleet | 12-Feb-10 | 3841AS1890-01 | Waveform Generator | Fails SMAT test # 4900 and will not adjust with calibration. | 19-Feb-10 | |
| Non-Fleet | 16-Feb-10 | 3841AS1830-01 | Pulse Generator | Fails DTI SMAT TG02 test # 2480 and 2482. | 19-Feb-10 | |
| Non-Fleet | 19-Feb-10 | 3841AS1860-01 | SGMA | Fails Calibration Test # 6118 MV = 44.978 Deg UL = 45.0137 Deg LL = 44.9937 Deg. OEM reports failure report as stating - RTCAL R40 produces an Error during SGMA Field Calibration routine. | ||
| Manual field calibration from SFP functions without error. | 04-Mar-10 | |||||
| Non-Fleet | 19-Feb-10 | 3841AS1580-01 | Waveform Digitizer | WFRD Fails Calibration intermittently, also causes STRG to fail calibration. | 22-Feb-10 | |
| Non-Fleet | 24-Feb-10 | 3841AS1860-01 | SGMA | SGMA # 00 Fails to Align: (2A1A3) failed to align and subsequently fails IST. Reset of the SGMA and station power cycle does not cleart he failure. | 17-Mar-10 | |
| Non-Fleet | 01-Mar-10 | 3841AS1880-01 | Rubidium | 2A1A12 CCA - Rubidium Standard will not initialize. Also, shield for J4 came off during replacement. | 02-Mar-10 | |
| Non-Fleet | 10-Mar-10 | 3841AS1880-01 | Rubidium | No card in the 2A1 chassis will initialize when this card is installed. Therefore, suspect a MXI bus interface failure. | 17-Mar-10 | |
| Fleet | 13-Nov-09 | 3841AS1315-01 | VT-5000-RT Switch Module | GPIB SWITCH CARD 1A2A5 RELAY FAILURE DUE TO EXCESSIVE CURRENT. TPS induced failure. | 24-Nov-09 | |
| Non-Fleet | 15-Mar-10 | 3841AS2115-02 | Down Converter | Cannot Align. | 17-Mar-10 | |
| Non-Fleet | 15-Mar-10 | 3841AS1850-01 | Counter/Timer, VXI | Fails Calibration Test # 2728. | 24-Mar-10 | |
| USAF | 16-Mar-10 | 3841AS1610-01 | 32VDC Power Supply | SMAT failed test 3312 with a reading of MV = -4 ohms LL = 1000 ohms. Diagnostic test number 8485.02 failed with a MV = -4 ohms LL = 1000 ohms. PCOF = 1A4PS2. Swapped 1A4PS2 with 1A4PS1. SMAT failed test 3312 with a reading of MV = -4 ohms LL = 1000 ohms. | 16-Mar-10 | |
| Fleet | 11-Feb-10 | 3841AS1231-01 | CASS to M9 CRB | CIB CAUSES DTI SMAT TO FAIL TESTING. | 12-Feb-10 | |
| Fleet | 11-Feb-10 | 3841AS1860-01 | SGMA (Black Fin) | Bench fails SGMA CAL Test # 6006.001 | 11-Feb-10 | |
| Fleet | 22-Feb-10 | 3841AS1840-01 | Multimeter, Digital, VXI | DMM FAILS INITIALIZATION | 25-Feb-10 | |
| Fleet | 23-Feb-10 | 3841AS1860-01 | SGMA (Black Fin) | GMA WILL NOT PASS SELF TEST IAW RTCASS | 23-Feb-10 | |
| Fleet | 10-Mar-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI#4 FAILS SELF TEST | 10-Mar-10 | |
| Fleet | 10-Mar-10 | 3841AS1860-01 | SGMA (Black Fin) | CAUSES RTCASS BENCH TO FAIL IST TEST NUMBER 6715 DURING RTSMAT FOR SGMA | 10-Mar-10 | |
| Fleet | 17-Mar-10 | 3841AS1580-01 | Waveform Digitizer | WFRD FAILS CALIBRATION INTERMITTENTLY, ALSO CAUSES PGEN TO FAIL CALIBRATION. | 17-Mar-10 | |
| Non-Fleet | 19-May-09 | 3841AS1880-01 | Rubidium | RBCLK fails to initialize | 09-Jun-09 | |
| Fleet | 12-Mar-10 | 3841AS2360-01 | System Monitor CCA | Monitor card does not communicate with station assets. | 12-Mar-10 | |
| Fleet | 12-Mar-10 | 3841AS2360-01 | System Monitor CCA | CPU Fails Power up diagnostics | 12-Mar-10 | |
| Fleet | 12-Mar-10 | 3841AS2360-01 | System Monitor CCA | Environmental card will not communicate with station assets. | 12-Mar-10 | |
| Fleet | 12-Mar-10 | 3841AS2360-01 | System Monitor CCA | Causes bench to not read environmental sensors | 12-Mar-10 | |
| Fleet | 02-Mar-10 | 3841AS2010-01 | Signal Generator | CAUSES RT BENCH TO FAIL SELF MAINTENANCE | 03-Mar-10 | |
| Fleet | 05-Mar-10 | 3841AS2010-02 | Signal Generator | SIGNAL GENERATOR FAILS TO INITIALIZE DURING POWER-UP, NEEDS TO BE REPLACED | 08-Mar-10 | |
| Fleet | 22-Feb-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES RT STATION POWER UP FAULTS. No output. | 03-Mar-10 | |
| Fleet | 22-Mar-10 | 3841AS1610-02 | 100 VDC Power Supply | ATI CARD LOCKED UP, CAUSES RT STATION TO FAIL SMAT | 22-Mar-10 | |
| Fleet | 22-Feb-10 | 3841AS1620-01 | High Watt Power Load | ACTIVE LOAD CAUSES POWER UP FAULTS ON RT STATION. No output. | 03-Mar-10 | |
| Fleet | 20-Nov-09 | 3841AS1610-01 | 32VDC Power Supply | FAILS TO APPLY POWER | 20-Nov-09 | |
| Fleet | 20-Nov-09 | 3841AS1610-02 | 100 VDC Power Supply | Fails diagnostics test | 20-Nov-09 | |
| Fleet | 22-Feb-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | CAUSES POWER UP FAULTS | 03-Mar-10 | |
| Fleet | 08-Feb-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES BENCH TO FAIL SMAT | 08-Feb-10 | |
| Fleet | 22-Feb-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES RT STATION POWER UP FAULTS. No output. | 03-Mar-10 | |
| Fleet | 22-Feb-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES RT STATION POWER UP FAULTS | 03-Mar-10 | |
| Fleet | 22-Feb-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES RTCASS BENCH TO FAIL ON POWER-UP. No output. | 03-Mar-10 | |
| Fleet | 05-Mar-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | POWER SUPPLY IS CAUSING STATION UAA056 TO FAIL | 05-Mar-10 | |
| Non-Fleet | 05-Apr-10 | 3841AS2115-02 | Down Converter | Does not communicate properly with RTCASS station - does not report S/N and has wrong Firmware Version on report. Replacing Ethernet Cable 2W9 to Downconverter did not help. | 07-Apr-10 | |
| Non-Fleet | 06-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | Unit consistantly fails Instrument Self Test (IST). Firmware upgrade to Rev J did not fix the problem. |
| Note: This unit should be in warranty - UAA091 | 07-Apr-10 | |||||
| Fleet | 08-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | 2A1A3 FAILS CALIBRATION TEST 6102.002 | 08-Apr-10 | |
| Fleet | 02-Apr-10 | 3841AS1231-01 | CASS to M9 CRB | 1A1A10A1 VICD CAUSES TG2 TO FAIL RTSMAT. CONSUMABLE ITEM. | 02-Apr-10 | |
| Fleet | 02-Apr-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CARD FAILS INSTRUMENT SELF TEST IAW 16-30USM702-2-2 | 02-Apr-10 | |
| Fleet | 02-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS TO PASS CALIBRATION IN ACCORDANCE WITH RTCASS | 02-Apr-10 | |
| Fleet | 30-Mar-10 | 3841AS1880-01 | Rubidium | RUBIDIUM STANDARD FAILS TO SENSE INPUTS. NO PBL | 31-Mar-10 | |
| Fleet | 30-Mar-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI HAS STRING BUFFER OVERFLOW ERROR. NO PBL | 31-Mar-10 | |
| Fleet | 24-Mar-10 | 3841AS1830-01 | Pulse Generator | 2A5A10 PGEN FAILS TO INITIALIZE | 24-Mar-10 | |
| Fleet | 24-Mar-10 | 3841AS1314-01 | VT-6000-RT Switch Module | CCA CAUSES RTCASS BENCH TO SPIKE VOLTAGE DURING TESTING | 25-Mar-10 | |
| Fleet | 25-Mar-10 | 3841AS1850-01 | Counter/Timer, VXI | FTIC WAS NOT RECOGNIZED BY CPU UPON POWER UP | 25-Mar-10 | |
| Fleet | 24-Mar-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS TO PASS SELF TEST IN ACCORDANCE WITH RTCASS | 25-Mar-10 | |
| Non-Fleet | 12-Apr-10 | 3841AS1230-01 | Digital CRB (DTI) | With this card installed (slot 3), DTI Alignment fails and DTI # 01 - DTI # 07 fail IST. With this card removed or a different card in the slot, IST and diagnostic self test pass on all cards. | 13-Apr-10 | |
| Non-Fleet | 16-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | Fault light is ON. Unit consistantly fails Instrument Self Test (IST). Firmware upgrade to Rev J and field alignment did not fix the problem. NOTE: This unit should be in warranty - UAA092. | 22-Apr-10 | |
| Non-Fleet | 16-Apr-10 | 3841AS1580-01 | Waveform Digitizer | FAILS CAL TEST #5575-007, FAILED TWICE IN 2 DIFFERENT SLOTS | 28-Apr-10 | |
| Non-Fleet | 19-Apr-10 | 3841AS2115-02 | Down Converter | HPSA fails SMAT and CAL, if alignment fail (Status BIT 4). | 04-May-10 | |
| Non-Fleet | 21-Apr-10 | 3841AS2115-02 | Down Converter | Fails internal self-cal & alignment. | 21-Apr-10 | |
| Non-Fleet | 23-Apr-10 | 3841AS2010-01 | Signal Generator | Will not inialize on power up. | 23-Apr-10 | |
| Non-Fleet | 23-Apr-10 | 3841AS1520-01 | Chassis Assembly, VXI, Low Pwr, Opt B | TEMP Sensor 1A3IN gives intermittent readings, power supply is also showing faults during power up initiation. | 23-Apr-10 | |
| Fleet | 14-Apr-10 | 3841AS1610-01 | 32VDC Power Supply | POWER SUPPLY CAUSES RTCASS TO NOT BE ABLE TO FULLY POWER UP | 14-Apr-10 | |
| Non-Fleet | 26-Apr-10 | 3841AS1231-01 | CASS to M9 CRB | RTSMAT fails test number 2484 custom interface board (1A1A10A) PCOF. Researched through Publication 16-30USM702-2-1 and applicable ATI for RTSMAT and throubleshot accordingly. Traced all wire paths wire paths checked good. R/R 1A1A10A with known assembly | 27-Apr-10 | |
| Fleet | 23-Apr-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA CAUSES DTI SMAT TO FAIL | 23-Apr-10 | |
| Fleet | 22-Apr-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA #02 FAILS SELF TEST | 22-Apr-10 | |
| Fleet | 22-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA PASSES CALIBRATION BUT FAILS IST AND ALIGNMENT | 22-Apr-10 | |
| Fleet | 19-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | FAILS IST, WILL NOT RESET AND FAILS TN 6102 DURING STATION CAL. | 19-Apr-10 | |
| Fleet | 15-Apr-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA CAUSES CASE TO FAIL IST FOR STRG AND GPI | 15-Apr-10 | |
| Fleet | 14-Apr-10 | 3841AS1580-01 | Waveform Digitizer | WFRD FAILS SMAT | 14-Apr-10 | |
| Non-Fleet | 27-Apr-10 | 3841AS1880-01 | Rubidium | ESD (2A1A12) Reported as "PASS" but the measurement on the external counter indicated an Out-of-Tolerance reading. T# 1030 MV 100.0000000010, UL 100.000000010, LL 99.999999990. This ESD needs to be replaced. | 06-May-10 | |
| USAF | 29-Apr-10 | 3841AS1231-01 | CASS to M9 CRB | 1A1A10A1 causes RTSMAT to fail @ step number 2484. | 29-Apr-10 | |
| Fleet | 29-Apr-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA FAILS SELF TEST | 29-Apr-10 | |
| Fleet | 26-Apr-10 | 3841AS2010-01 | Signal Generator | SIGNAL GENERATOR FAILS SELFTESTING IN ACCORDANCE WITH RTCASS | 26-Apr-10 | |
| Fleet | 22-Apr-10 | 3841AS1610-03 | 450VDC Power Supply | CAUSES IEH_DCPS FAULTS UPON POWER UP | 22-Apr-10 | |
| Fleet | 22-Apr-10 | 3841AS1610-01 | 32VDC Power Supply | CAUSES IEH_DCPS FAULTS UPON POWERING UP | 22-Apr-10 | |
| Non-Fleet | 04-May-10 | 3841AS1860-01 | SGMA (Black Fin) | Unit has Rev J Firmware. Fails the following SMAT Test: 6150.003, MV 44.9874 - UL 45.1, LL 44.99 |
6154.003, MV 135.0381, UL 135.0104, LL 134.8904
6158.003, MV 224.9677, UL 225.0103, LL 224.9903
| NOTE: This unit rec'd from CLS on 4/21/2010 on voucher # I100 | 17-May-10 | |||||
| Non-Fleet | 04-May-10 | 3841AS1840-01 | Digital Multimeter (DMM) | Fails DMM CAL Test # 2415 & 2570. | 11-May-10 | |
| Non-Fleet | 12-May-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | Unit failing calibration test T1310, is 21.9 mVRMS at 45Hz, Also has excessive AC content during DC output. |
| NOTE: This unit should be in warranty - UAA093. | 19-May-10 | |||||
| Non-Fleet | 11-May-10 | 3841AS1250-01 | Serial Bus Interface (BTI) | BTI Instrument VXI card fails to register and be recognized by Test executive Software. | ||
| Non-Fleet | 14-May-10 | 3841AS1231-01 | CASS to M9 CRB | Measures -1.2V out of J11 32A on GPI. Verified incorrect voltage by Gregory Berry. | 19-May-10 | |
| Non-Fleet | 17-May-10 | 3841AS1230-01 | Digital CRB (DTI) | Fails power up, DTI # 07 Initialize. | 18-May-10 | |
| Non-Fleet | 18-May-10 | 3841AS2010-01 | Signal Generator | Unit has bad center conductor on RF out, fails SMAT. | 21-May-10 | |
| Non-Fleet | 27-May-10 | 3841AS1850-01 | Counter/Timer, VXI | Unit Fails to Initialize. Error IMH-FTIC Code: BFFF015. |
| NOTE: This Unit should be in warranty - UAA095. | 04-Jun-10 | |||||
| Non-Fleet | 28-May-10 | 3841AS1840-01 | Digital Multimeter (DMM) | DMM failed calibration test 2160 MV: 0.010187 VRMS UL: 0.010046 LL: 0.009954. | 01-Jun-10 | |
| Non-Fleet | 03-Jun-10 | 3841AS2010-01 | Signal Generator | Unit Continuously Fails Instrument Self Test (IST). | 17-Jun-10 | |
| Non-Fleet | 03-Jun-10 | 3841AS2010-01 | Signal Generator | Unit Continuously Fails Instrument Self Test (IST). | 17-Jun-10 | |
| Non-Fleet | 04-Jun-10 | 3841AS2010-01 | Signal Generator | RFSG # 00 Attempted IST and RTSMAT. SMAT FTN: 1080.048. Moved RFSG # 02 to RT Station UAA012, Still failed same. | 09-Jul-10 | |
| Non-Fleet | 07-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | Unit fail diagnostic self test run during DTI calibration. | 18-Jun-10 | |
| Non-Fleet | 08-Jun-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | Unit failing Zero Calibration. | 11-Jun-10 | |
| Fleet | 07-May-10 | 3841AS1610-01 | 32VDC Power Supply | POWER SUPPLY HAS NO OUTPUT AND PREVENTS STATION FROM POWERING UP | 07-May-10 | |
| Fleet | 13-May-10 | 3841AS2010-01 | Signal Generator | RFSG FAILS TEST 7810 WITH READING OF -72.2449 | 13-May-10 | |
| Fleet | 18-May-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS INITIALIZATION ON POWER UP | 18-May-10 | |
| Fleet | 18-May-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS INITIALIZATION ON POWER UP | 18-May-10 | |
| Fleet | 20-May-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS BUILT IN TEST. NO PBL | 20-May-10 | |
| Fleet | 21-May-10 | 3841AS2115-02 | Down Converter | SPECAN FAILS SMAT IAW RTCASS TESTING AND TPI 1909AS999 | 21-May-10 | |
| Fleet | 20-May-10 | 3841AS1610-01 | 32VDC Power Supply | POWER SUPPLY SHOWS UNHEALTHY IN TOI. VERIFIED BAD WITH KNOWN GOOD POWER SUPPLY. | 20-May-10 | |
| Fleet | 24-May-10 | 3841AS1315-01 | VT-5000-RT Switch Module | GPI J9 CAUSES OTPS 4 TO FAIL SELF TEST T/N 3080 | 24-May-10 | |
| Fleet | 24-May-10 | 3841AS1230-01 | Digital CRB (DTI) | CAUSES INITIALIZATION FAILURES DURING BENCH POWER UP | 24-May-10 | |
| Fleet | 08-Jun-10 | 3841AS2115-02 | Down Converter | CAUSES RTCAL TO FAIL SPECAN CAL T/N 6364.004 | 08-Jun-10 | |
| Fleet | 03-Jun-10 | 3841AS1610-01 | 32VDC Power Supply | FAILS TEST NUMBER 4258 DURING CALIBRATION | 03-Jun-10 | |
| Fleet | 04-Jun-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | FAILS CALIBRATION TEST # 1354 | 04-Jun-10 | |
| Fleet | 04-Jun-10 | 3841AS1315-01 | VT-5000-RT Switch Module | CAUSES FAILURE DURING SAFE TO TURN ON FOR CAL ID | 04-Jun-10 | |
| Fleet | 04-Jun-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Fails during calibration | 04-Jun-10 | |
| Non-Fleet | 10-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | FAILED IST AND RTSMAT. SMAT FTN: 1080.023, PCOF: 1A1A9. MOVED 1A1A9 TO SLOT 1A1A8 FAILED, FTN: 1080.024, PCOF: 1A1A8. RAN M9 SELFTEST, FAILS NUMEROUS ALIGNMENT TEST. | 16-Jun-10 | |
| Non-Fleet | 14-Jun-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | Fails calibration adjust test # 1630. | 17-Jun-10 | |
| USAF | 14-Jun-10 | 3841AS1860-01 | SGMA | SGMA (2A1A3) won't reset or align, Sta: UAA019 fails IST, Swapped SGMA's between UAA0019 and UAA0085, without calibration, UAA0019 passes with known good SGMA from Sta: UAA0085. | 16-Jun-10 | |
| Non-Fleet | 15-Jun-10 | 3841AS1830-01 | Pulse Generator | Failure on power up. | 17-Jun-10 | |
| FLEET | 11-Jun-10 | 3841AS1610-01 | 32VDC Power Supply | VERIFIED BAD. CAUSES BENCH TO FAIL POWER UP. SMOKED AND WOULD NOT TURN ON | 11-Jun-10 | |
| Non-Fleet | 16-Jun-10 | 3841AS1535-01 | RF Switch, SMP6101 | Fails WFRD CAL. Test # 3335.02. | 24-Jun-10 | |
| Non-Fleet | 16-Jun-10 | 3841AS1231-01 | CASS to M9 CRB | Fails RT SMAT TG02 # 2484.00. | 17-Jun-10 | |
| Non-Fleet | 21-Jun-10 | 3841AS2115-02 | Down Converter | SPECAN # 00 passes alignment and can intermittently fail 1ST reporting a SPECAN # 00 selftest error EC: -79991000, selftest failed. -340: callibration failed: Align_2ND_LO_PWR, -89983009: Instrument calibration has failed with the following conditions RF | 05-Aug-10 | |
| Non-Fleet | 21-Jun-10 | 3841AS1730-01 | DCPS Isolation Assy | Unit Fails SMAT. |
Note - No replacement required. Utilized 1A5A1 from station UAA003 which was excess after ECP5 Modification.
| USAF | 22-Jun-10 | 3841AS1860-01 | SGMA (Black Fin) | Fails SMAT and CAL intermittently. | 24-Jun-10 |
| Non-Fleet | 22-Jun-10 | 3841AS1240-01 | Digital CRB (DTI) | Error 39 while loading a large Digital pattern. | 01-Jul-10 |
| Non-Fleet | 22-Jun-10 | 3841AS1880-01 | Rubidium | Bad 10MHZ out of J18 causing multiple instruments to fail IST. | 22-Jun-10 |
| Non-Fleet | 23-Jun-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | J2 Connector on Power Supply has broken piece. | 28-Jun-10 |
| Non-Fleet | 23-Jun-10 | 3841AS1211-01 | Chassis Assembly, VXI, Hi Pwr | Chassis Backplane had Catastrophic Failure - Burned & Charred near C135. | 02-Jul-10 |
| Non-Fleet | 23-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | Damage to lower rear VXI connector caused by 1A1 backplane failure. | 30-Jun-10 |
| Non-Fleet | 25-Jun-10 | 3841AS2115-02 | Down Converter | Fails to communicate, verified bad by Gregory Berry. | 02-Jul-10 |
| Non-Fleet | 28-Jun-10 | 3841AS1536-01 | Relay Driver, SMP7500 | BAD/BROKEN PIN, RECEIVED BAD IN STATION | 30-Jun-10 |
| Non-Fleet | 30-Jun-10 | 3841AS1231-01 | CASS to M9 CRB | RTSMAT FAILS TEST # 2484. PCOF: 1A1A10A1, 1A1A10. SWAPPED |
1A1A10A1 FROM STATION UAA011 AND RAN RTSMAT TG-2, PASS. REINSTALLED
| ORIGINAL 1A1A10A1 AND RAN RTSMAT TG-2, FAIL TEST #2454. | 30-Jun-10 | |||||
| Non-Fleet | 30-Jun-10 | 3841AS2115-02 | Down Converter | Unit Initializes OK, but FAILS instrument self test. | 13-Jul-10 | |
| Non-Fleet | 30-Jun-10 | 3841AS1240-01 | Central Resource Board (CRB) | FAILS SMAT TEST # 2494 2495 AND 2496 | 12-Jul-10 | |
| Non-Fleet | 30-Jun-10 | 3841AS1880-01 | Rubidium | POWER UP FAILURE | 02-Jul-10 | |
| Non-Fleet | 07-Jul-10 | 3841AS1220-01 | Slot 0 Controller | 1A1A0 Slot Zero Controller | ||
| Controller Card apparently damaged by 1A1 Chassis Backplane Catastrophic Failure - prevents some DTI cards from initializing | 15-Jul-10 | |||||
| Non-Fleet | 07-Jul-10 | 3841AS1230-01 | Digital CRB (DTI) | 1A1A3, | ||
| Card indicates that it is in the 1A1A3 position no matter where the card is actually located. Possibly damaged by 1A1 Chassis Failure. | 16-Jul-10 | |||||
| Non-Fleet | 07-Jul-10 | 3841AS1880-01 | Rubidium | DOES NOT PROVIDE 10MZ, ASSET FAILS SMAT | 12-Jul-10 | |
| Non-Fleet | 08-Jul-10 | 3841AS1840-01 | Digital Multimeter (DMM) | FAILS ID TEST, SMAT TEST # 0400 & 0406, CAL TEST # 0405 | 12-Jul-10 | |
| Fleet | 16-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI FAILS INITIAL SELF TEST. NO PBL | 16-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1830-01 | Pulse Generator | PGEN FAILS TO INITIALIZE | 17-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1830-01 | Pulse Generator | FAILS TO INITIALIZE IN RTCASS UAA022 | 17-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1830-01 | Pulse Generator | PGEN FAILS TO INITIALIZE IN RTCASS | 17-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | CCA CAUSES BENCH TO FAIL DTI SMAT | 17-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | CCA CAUSES ALL DTI CARDS TO FAIL IST. | 17-Jun-10 | |
| Fleet | 17-Jun-10 | 3841AS1860-01 | SGMA (Black Fin) | SYNCRO CAUSES SGMA TO FAIL IST | 23-Jun-10 | |
| Fleet | 22-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI FAILS SMAT. FAILS T/N 2426 | 22-Jun-10 | |
| Fleet | 25-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA FAILS SMAT ON RTCASS | 25-Jun-10 | |
| Fleet | 25-Jun-10 | 3841AS1850-01 | Counter/Timer, VXI | FTIC FAILS CALIBRATION | 25-Jun-10 | |
| Fleet | 28-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CCA FAILS SMAT | 28-Jun-10 | |
| Fleet | 04-Jun-10 | 3841AS2360-01 | System Monitor CCA | CCA CAUSES UUT TO FAIL HEARTBEAT MONITOR CHECK. | 04-Jun-10 | |
| Fleet | 09-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | FAILS INSTRUMENT SELF TEST (IST) | 09-Jun-10 | |
| 20-Jul-10 | 3841AS1231-01 | CASS to M9 CRB | Unknown | 21-Jul-10 | ||
| 3841AS1231-01 | CASS to M9 CRB | Unknown | ||||
| Fleet | 22-Jun-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | LFC FAILS | 22-Jun-10 | |
| 3841AS1231-01 | CASS to M9 CRB | Unknown | ||||
| Non-Fleet | 13-Jul-10 | 3841AS1315-01 | VT-5000-RT Switch Module | K26 has 3.1 ohms of resistance | 16-Jul-10 | |
| Non-Fleet | 14-Jul-10 | 3841AS1620-01 | 32VDC Power Supply | Unit Has Vibration Sound when programming output voltage. | 20-Jul-10 | |
| USAF | 19-Jul-10 | 3841AS1850-01 | Counter/Timer, VXI | Fails in Calibration | 30-Jul-10 | |
| USAF | 19-Jul-10 | 3841AS1620-01 | 32VDC Power Supply | Run time error during calibration | 02-Aug-10 | |
| Non-Fleet | 20-Jul-10 | 3841AS2010-01 | Signal Generator | RFSG#02 ATTEMPTED IST AND RTSMAT, BOTH FAILED. ASSET DOES PASS RTCAL. IST ERROR, EC: -79991000 IST FAILED, -10002. SEE ATTACHED IST ERROR LOG. NOTE: HAVE HAD SEVERAL POWER OUTAGES DURING THE PASS TWO WEEKS. | 23-Jul-10 | |
| Non-Fleet | 22-Jul-10 | 3841AS1860-01 | SGMA (Black Fin) | Unit Fails IST and Alignment. Updated Firmware using another station (UAA098). Unit still fails. | 27-Jul-10 | |
| Non-Fleet | 22-Jul-10 | 3841AS1211-01 | Chassis Assembly, VXI, Hi Pwr | Chassis backplane failure at 1A1A8 | 27-Jul-10 | |
| Non-Fleet | 22-Jul-10 | 3841AS1230-01 | Digital CRB (DTI) | Damage to rear connector related to 1A1 backplane failure. | 26-Jul-10 | |
| Non-Fleet | 28-Jul-10 | 3841AS2010-01 | Signal Generator | IST fails for 2A3A2 RFSG#01 "SELF TEST ERROR EC: 79991000 SELF |
TEST FAILED -10002 RF SIGNAL GEN IVI SELFTEST FAILED.
ATTEMPTED TO RUN RTSMAT, FAILED, THEN RTCAL RF TEST GROUP,
OPTION 3 FOR RFSG3/RFSG#01/HPSG3 AND FAILED TEST 6256.015
| WITH A MEASURED VALU | 05-Aug-10 | |||||
| Non-Fleet | 29-Jul-10 | 3841AS2010-02 | Signal Generator | No output at 10 MHz Reference Output. 10 MHz Ref Input OK | 04-Aug-10 | |
| Fleet | 28-Jun-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI CARD FAILS TO INITIALIZE-CAUSES BENCH TO FAIL AUTOMATIC DIAGNOSTICS TESTS IAW RTCASS TESTING. | 28-Jun-10 | |
| Fleet | 02-Jul-10 | 3841AS1860-01 | SGMA | SGMA FAILS TO PASS CALIBRATION IN ACCORDANCE WITH RTCASS | 02-Jul-10 | |
| Fleet | 08-Jul-10 | 3841AS1860-01 | SGMA (Black Fin) | SGMA FAILS CAL T/N 6150.003 | 08-Jul-10 | |
| Fleet | 09-Jul-10 | 3841AS1315-01 | VT-5000-RT Switch Module | CCA CAUSES RTCASS BENCH TO FAIL RTSMAT T/N 2815 | 09-Jul-10 | |
| Fleet | 15-Jul-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | ACPS FAILS INTERMENTLY DURING UUT TESTING | 15-Jul-10 | |
| Fleet | 15-Jul-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | ACPS FAILS INTERMENTLY DURING UTT TESTING | 15-Jul-10 | |
| Fleet | 15-Jul-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | ACPS FAILS INTERMINTENTLY DURING UUT TESTING | 15-Jul-10 | |
| Fleet | 16-Jul-10 | 3841AS2010-01 | Signal Generator | FAILS CALIBRATION AND SMAT IN ACCORDANCE WITH RTCASS | 16-Jul-10 | |
| Fleet | 28-Jul-10 | 3841AS1610-02 | 100 VDC Power Supply | POWER SUPPLY FAILS TO TALK WITH STATION | 28-Jul-10 | |
| Fleet | 29-Jul-10 | 3841AS2010-02 | Signal Generator | WILL NOT INITIALIZE. CAUSES BENCH TO FAIL SELF TEST. | 29-Jul-10 | |
| Fleet | 29-Jul-10 | 3841AS1315-01 | VT-5000-RT Switch Module | CAUSES GPI SMAT TO FAIL T/N 1112. VERIFIED BAD | 29-Jul-10 | |
| Fleet | 03-Aug-10 | 3841AS2010-01 | Signal Generator | RFSG02 FAILS RTCASS CAL T/N 6220.001 | 03-Aug-10 | |
| Fleet | 04-Aug-10 | 3841AS2010-02 | Signal Generator | CAUSES RTCASS BENCH TO FAIL IST | 04-Aug-10 | |
| Fleet | 04-Aug-10 | 3841AS2010-01 | Signal Generator | POWER METER FAILS SELF MAINTENANCE AUTOMATED TESTING | 04-Aug-10 | |
| Fleet | 12-Aug-10 | 3841AS2115-03 | Spectrum Analyzer / RF Pwr Meter | POWER METER FAILS SELF MAINTENANCE AUTOMATED TESTING | 12-Aug-10 | |
| Non-Fleet | 10-Aug-10 | 3841AS1250-01 | Serial Bus Interface (BTI) | While attempting to verify/regression test a TPS (H1 AWIRT) |
using B75.1/R46.1 Station software, The TPS failed during its' Comm. interface section of testing. I then ran SMAT on BTI and got the following repeatable failure,
| BTI SMAT Fails @ TN 5775 R | 18-Aug-10 | |||||
| Non-Fleet | 12-Aug-10 | 3841AS1590-01 | Analog Test Instrument (ATI) | BROKEN PIN ON J1A | 16-Aug-10 | |
| Non-Fleet | 12-Aug-10 | 3841AS1590-01 | Analog Test Instrument (ATI) | WILL NOT INITIALIZE ON POWER UP | 16-Aug-10 | |
| Non-Fleet | 13-Aug-10 | 3841AS2115-03 | Spectrum Analyzer / RF Pwr Meter | PWRMTR#00 FAILED RTCAL TEST # 2916.005 (PCOF 2A4A2), PASS RTSMAT. POWERED DOWN STATION / PWRMTR#00 TIMED OUT DURING STATION POWER-UP. PWRMTR#00 FAILED IST DURING POWER UP. TRIED TO RESET PWRMTR#00, FAILED. | 24-Aug-10 | |
| Non-Fleet | 13-Aug-10 | 3841AS1533-01 | Power Switch | Transistor Q1 has blown its top! | 20-Aug-10 | |
| Non-Fleet | 13-Aug-10 | 3841AS1532-01 | Base Unit | Double Wide Slot Carrier Failure - This item NOT on CLS list of repairables | 20-Aug-10 | |
| Non-Fleet | 18-Aug-10 | 3841AS1860-01 | SGMA (Black Fin) | Unit Fails Instrument Self Test (IST) and Alignment. Installed new software V 09.06.21.12.21.12 and aligned ofter warmup. New Software did not help. | 19-Aug-10 | |
| Non-Fleet | 18-Aug-10 | 3841AS2115-02 | Down Converter | Unit Fails to Initialize. | 18-Aug-10 | |
| Non-Fleet | 19-Aug-10 | 3841AS1580-01 | Waveform Digitizer | Unit Fails SMAT Test 4300 and beyond. Replaced with another unit - working OK. | ||
| NOTE: This should be a Warranty Item | 25-Aug-10 | |||||
| Non-Fleet | 27-Aug-10 | 3841AS1590-01 | Analog Test Instrument (ATI) | FAILS RT SMAT TEST # 1204 & 1294 | 31-Aug-10 | |
| Non-Fleet | 25-Mar-09 | 3841AS1620-01 | 32VDC Power Supply | Unknown | 17-May-09 | |
| Non-Fleet | 25-Mar-09 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Unknown | 17-May-09 | |
| Non-Fleet | 27-Jan-10 | 3841AS2304-01 | ACPS | Unknown | 27-Jan-09 | |
| Fleet | 20-Aug-10 | 3841AS2360-01 | System Monitor CCA | CCA FAILS TO COMMUNICATE WITH TEMP SENSORS. | 20-Aug-10 | |
| Non-Fleet | 21-Jul-10 | 3841AS1590-01 | Analog Test Instrument (ATI) | FAILED CAL TEST 5575.002 MV=2.0, UL=6.0 UNITS TESTCNT. CCA STARTED GIVING AN INITIALIZATION WARNING "ENTERNAL CALIBRATION REQUIRED". THE CARD ALSO STARTED FAILING IST "ALIGN FAIL-CARD 1" | 21-Jul-10 | |
| Non-Fleet | 09-Sep-10 | 3841AS1860-01 | SGMA | SGMA goes into IST and hangs up the station. Powered down and back up, SGMA passed power up IST (hand shack) but locks up during Self Test IST. R&Red with SGMA out of UAA008, ran IST and Cal, both pass, running SMAT. Systeme SW 1.0.75, Cal SW R46 | 13-Sep-10 | |
| Non-Fleet | 13-Sep-10 | 3841AS1580-01 | Waveform Digitizer | FAILS CALIBRATION TEST # 3066 and 3326 | 13-Sep-10 | |
| Non-Fleet | 13-Sep-10 | 3841AS1580-01 | Waveform Digitizer | FAILS CALIBRATION TEST # 3016, INPUT 1, 50 OHMS, MEASURES 53.14 OHMS | 20-Sep-10 | |
| Non-Fleet | 14-Sep-10 | 3841AS1534-01 | LF SWITCH, SMP5003 | BROKEN PIN ON CONNECTOR | 05-Oct-10 | |
| USAF | 21-Sep-10 | 3841AS1230-01 | Digital CRB (DTI) | Causes RTCASS to fail SMAT @ 2592 | 23-Sep-10 | |
| Non-Fleet | 21-Sep-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | DURING RTSMAT OUTPUT DID NOT REACH SPECIFIED VOLTAGE LEVEL WITHIN 530mSEC ON CHANNEL 1, ERROR CODE DEADOBEE | 28-Sep-10 | |
| Non-Fleet | 23-Sep-10 | 3841AS1860-01 | SGMA | SGMA fails IST and calibration at test 6100.001 out of tolerance, it also failed "Field Cal". | 23-Sep-10 | |
| Non-Fleet | 24-Sep-10 | 3841AS1890-01 | Waveform Generator | Failed RTSMAT Test 5020. No output on AWFG | 28-Sep-10 | |
| Non-Fleet | 28-Sep-10 | 3841AS2304-01 | 135VAC Power Supply (ACPS) | Cooling Fan Failure | 04-Oct-10 | |
| Non-Fleet | 28-Sep-10 | 3841AS1315-01 | VT-5000-RT Switch Module | ON 9/24/10 AT 13:25 AN RTCASS STATION/TPS EVENT OCCURRED WHILE USING BOEING STATION SOFTWARE DEVELOPMENTAL BUILD 76, WITH 4 BOEING PATCHES, AND ULAS DEVELOPMENTAL DLL, DATED 09/22/10. DURING TPS DEVELOPMENT EXECUTION OF EA6B OTPS 5, UUT 451, RTCASS STATI | 22-Oct-10 | |
| Non-Fleet | 30-Sep-10 | 3841AS2010-01 | Signal Generator | HPSG#02 fails true IST, passes initial hand shake IST. | 01-Oct-10 | |
| Non-Fleet | 01-Oct-10 | 3841AS2210-01 | Low Freq. Callibrator (LFC) | Will not Initialize | 07-Oct-10 | |
| Non-Fleet | 04-Oct-10 | 3841AS1580-01 | Waveform Digitizer | WFRD fails cal test 3331 MV: 1E+38 UL: .118 LL: .082 DBM | 05-Oct-10 | |
| Non-Fleet | 06-Oct-10 | 3841AS1532-01 | Base Unit | ON 10/04/10 THE VXI BASE UNIT 1A3A7 FAILED RTSMAT TEST 1304 WITH A MEASURED VALUE OF 2.1111 VDC, UPPER LIMIT=0.732, LOWER LIMIT=0.545. RTSMAT DIAGNOSTIC TEST REPORTED THE 1A3A1 Ai7 CARD AS THE PROBABLE CAUSE OF FAILURE. THE Ai7 CARD WAS VERIFIED TO BE GO | 06-Oct-10 | |
| Fleet | 20-Aug-10 | 3841AS1860-01 | SGMA (Black Fin) | CAUSE BENCH TO FAIL FOR CAL/SMAT/SELF TEST | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS2115-03 | Spectrum Analyzer / RF Pwr Meter | POWER METER FAILS CAL T/N 2916.002, VERIFIED IN TWO BENCHES | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1230-01 | Digital CRB (DTI) | Cause DTI #04 to fail self test and SMAT | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1620-01 | 32VDC Power Supply | POWER SUPPLY DOES NOT COMMUNICATE WITH STATION | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1230-01 | Digital CRB (DTI) | DTI#4 FAILS SMAT | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1230-01 | Digital CRB (DTI) | causes bench to fail self test | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1830-01 | Pulse Generator | FAILS SMAT | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1830-01 | Pulse Generator | TALKS THROUGH MIX/VIX BUS BUT FAILS TO INITIALIZE THROUGH RTCASS SOFTWARE | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1830-01 | Pulse Generator | TALKS THROUGH MIX/VIX BUS BUT FAILS TO INITIALIZE THROUGH RTCASS SOFTWARE | 20-Aug-10 | |
| Fleet | 20-Aug-10 | 3841AS1830-01 | Pulse Generator | STRG FAILS SELF TEST IAW RTCASS | 20-Aug-10 |