AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

RFP N62742-18-R-1314, WON# 1396553, FY17 MCAF PROJECT PAF150400 APR EXPAND AIRCRAFT PARKING APRON, ROYAL

AUSTRALIAN AIR FORCE (RAAF) BASE DARWIN, AUSTRALIA

Amendment No. 0003 is continued on page 2.

1. CONTRACT ID CODE PAGE OF PAGES

1 6

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6274218R1314

X 9B. DATED (SEE ITEM 11)

21-Nov-2017

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer Xis extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-Jan-2018

CODE

NAVFAC PACIFIC

A-E/CONSTR CONTRACTS BRANCH (CODE ACQ31)

258 MAKALAPA DR STE 100

JBPHH HI 96860-3134

N62742 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

N6274218R1314 Amendment No. 0003

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

DOCUMENT 00100 INSTRUCTIONS TO PROPOSERS

Paragraph 1.7(c), 1st line – delete “subcontractors/”.

DOCUMENT 00800 LABOR REQUIREMENTS

Insert the following paragraph:

1.2 NORTHERN TERRITORY OF AUSTRALIA CONSTRUCTION INDUSTRY LONG SERVICE LEAVE

AND BENEFITS ACT AS IN FORCE AT 23 APRIL 2015

(a) Without limiting the Contractor's obligations under the Contract or otherwise at law or in equity, the Contractor shall comply with its obligations under the Long Service Leave Legislation.

(b) If required by the Long Service Leave Legislation, the Contractor must pay any levy, charge, contribution or associated amount in respect of the work performed under this Contract.

(c) Any amount paid by the Contractor under paragraph (b) is deemed to be included in the Contract Price and the Contractor will have no Claim against the United States arising out of or in connection with its obligations under this paragraph or the Long Service Leave Legislation.

DOCUMENT 00 01 15 LIST OF DRAWINGS

1.2 CONTRACT DRAWINGS

The following drawings are revised as of January 02, 2018:

NAVFAC DWG NO. TITLE

17210320 Existing Site Conditions and Boring and Test Pit Location Plan, Revised January 02, 2018

17210364 Storm Drain “C” and “D” Profiles, Revised January 02, 2018

17210367 Water Line “A” - Profile, Revised January 02, 2018

17210368 Water Line “B” - Profile, Revised January 02, 2018

These revised Drawings accompany this Amendment.

The following sketches dated January 02, 2018, are added to the list of drawings:

SK-001 BORING LOG – BH02

SK-002 BORING LOG – BH04

SK-003 BORING LOG – BH06

SK-004 BORING LOG – BH07

SK-005 BORING LOG – BH09

SK-006 BORING LOG – BH10

SK-007 BORING LOG – BH17

SK-008 TEST PIT LOG – TP 2

SK-009 TEST PIT LOG – TP 3

SK-010 TEST PIT LOG – TP 5

SK-011 TEST PIT LOG – TP 7

These Sketches accompany this Amendment.

On NAVFAC Drawing No. 17210309 (G-004)

Under “GENERAL NOTES”, add “25. AN AREA WITHIN 3.2 KILOMETERS FROM THE PROJECT SITE

WILL BE AVAILABLE FOR A CONSTRUCTION SITE OFFICE AND LAYDOWN AREA.”

On NAVFAC Drawing No. 17210320 (CW002)

Add boring locations for “BH02”, “BH04”, “BH06”, “BH07”, “BH09”, “BH10”, and “BH17”. See attached SK-001 through SK-007 for borehole logs.

Add test pit locations for “TP 2”, “TP 3”, “TP 5”, and “TP 7”. See attached SK-008 through SK-011 for test pit logs.

Under the “EXST ABANDONED BUILDING” callout, add “, SEE NOTE 3”.

Under “NOTES”, add “3. THE EXISTING ABANDONED BUILDING HAS ASBESTOS CONTAINING

MATERIALS. IF OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, NOTIFY CONTRACTING

OFFICER. ”

On NAVFAC Drawing No. 17210321 (CW101)

Under the “DEMOLISH EXST ABANDONED BUILDING” callout, add “, SEE NOTE 4”.

Under “NOTES”, add “4. THE EXISTING ABANDONED BUILDING HAS ASBESTOS CONTAINING

MATERIALS. IF OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, NOTIFY CONTRACTING

OFFICER. ”

On NAVFAC Drawing No. 17210323 (CW103)

Under “GENERAL CONSTRUCTION PHASING NOTES”, add “11. PHASE 1 AND PHASE 2 SHALL NOT BE

CONSTRUCTED SIMULTANEOUSLY.”

On NAVFAC Drawing No. 17210364 (CW438)

STORM DRAIN “D” – PROFILE, add Water Line “A” crossing.

STORM DRAIN “D” – PROFILE, replace “SD “D” STA 0+034.382 INV = 28.980±” with “SD “D”

STA 0+034.382± INV=29.030±”.

On NAVFAC Drawing No. 17210366 (CW451)

WATER PLAN, under “NOTES”, add “9. PROVIDE A MINIMUM OF ONE METER HORIZONTAL

CLEARANCE BETWEEN WATER LINE “A” AND ELECTRICAL DUCTLINE AND LIGHTING CONTROL

PANEL, SEE SHEET EL-201.”

WATER PLAN, under “NOTES” “10. PROVIDE A MINIMUM OF ONE METER HORIZONTAL CLEARANCE BETWEEN WATER LINE “B” AND FLOODLIGHT POLE FOOTING, SEE SHEETS S-501 AND EL-201.”

On NAVFAC Drawing No. 17210367 (CW452)

WATER LINE “A” – PROFILE, remove existing communication ductline and existing electric ductline crossings.

WATER LINE “A” – PROFILE, revise Water Line “A” profile from WL “A” STA 0+138.617 to WL “A”

STA 0+166.823.

WATER LINE “A” – PROFILE, add Storm Drain “D” crossing.

WATER LINE “A” – PROFILE, add electrical ductline and spare conduit ductline crossings.

WATER LINE “A” – PROFILE, delete “= WL “B” STA 0+000.000” callout at WL “A” STA 0+312.685.

WATER LINE “A” – PROFILE, revise the tee symbol to 300 mm.

On NAVFAC Drawing No. 17210368 (CW453)

WATER LINE “B” – PROFILE, revise Water Line “B” profile from STA 0+000.000 to STA 0+147.762±.

On NAVFAC Drawing No. 17210431 (EL-201)

NEW APRON EXPANSION FLOODLIGHTING PLAN, under “NOTES”, add “2. PROVIDE A MINIMUM OF

ONE METER HORIZONTAL CLEARANCE BETWEEN FLOODLIGHTING CONTROL PANEL AND WORK

SHOWN ON THIS DRAWING AND THE WATER LINES AND APPURTENANCES SHOWN ON SHEET

CW451.”

NEW APRON EXPANSION FLOODLIGHTING PLAN, add “, SEE NOTE 2” after “LIGHTING PANEL, SEE

C3/EL-502”.

On NAVFAC Drawing No. 17210434 (EL-503)

DETAIL C2, LIGHT POLE CROSS ARM DETAIL, add "LOW INTENSITY" before "DUAL HEAD

OBSTRUCTION LIGHT".

DETAIL C2, LIGHT POLE CROSS ARM DETAIL, add Note 4 "CONNECT FIXTURES AT 240V, PHASE TO

NEUTRAL, ALTERNATING BETWEEN BOTH PHASES. PROVIDE IN-LINE FUSING FOR EACH PHASE

CONDUCTOR IN BASE OF POLE SIZED FOR THE LOAD OF THE FIXTURES CONNECTED".

On NAVFAC Drawing No. 17210436 (EL-601)

DETAIL A1, ONE LINE DIAGRAM-BRA APRON LIGHTING, move “4 1/C 50mm2 Cu PVC/NY/PVC/PVC AND 50 MM2 ANNEALED EARTH CONDUCTOR” from 3P100A breaker in Non-Essential Panel to the existing 3P100A breaker in the Essential Panel within Substation 10.

DETAIL A1, ONE LINE DIAGRAM-BRA APRON LIGHTING, delete Note 3 below detail title as well as next to “3P100A” breaker in the Non-Essential Panel. Delete “3P100A” breaker in the Non-Essential Panel with replace with “3P50A” which is the existing condition.

SECTION 26 56 20.00 10 AIRFIELD LIGHTING AND VISUAL NAVIGATION AIDS

Paragraph 2.5 OBSTRUCTION LIGHTING AND MARKING

At the end of the paragraph, insert “The obstruction lights shall be dual head, incandescent, steady red low intensity light, E27 socket lamps of 55 Watts, lamp life of equal or greater than 8,000 hours, 230Vac, ICAO Annex 14 photometry, IP34 rated, body made of aviation yellow full colored polyamide reinforced with fiber glass, switching box made of aviation yellow painted cast aluminum, and stainless steel hardware.

Low intensity obstacle lights, for general applications, are to have the following characteristics:

(a) fixed lights showing red;

(b) a horizontal beam spread that results in 360° coverage around obstacle;

(c) a peak intensity of 100 cd minimum;

(d) a vertical beam spread (to 50% of peak intensity) of 10°;

(e) a vertical distribution with 100 cd minimum at +6° and +10° above the horizontal; and

(f) not less than 10 cd at all elevation angles between –3° and +90° above the horizontal."

SECTION 33 52 43.13 AVIATION FUEL PIPING

Paragraph 2.1.1 Steel Piping

Delete title “Steel Piping” and replace with “Stainless Steel Piping”

Paragraph 2.1.1(a)

At two locations in first sentence, delete “304L” and replace with “316L”.

Paragraph 2.1.2.2(a)

In first sentence, delete “304L” and replace with “316L”.

Paragraph 2.1.2.2(b)

In first sentence, delete “304 or 304L” and replace with “316 or 316L”.

Paragraph 2.1.2.2(c)

Delete “304 or”.

Paragraph 2.1.2.2(d)

In first sentence, delete “304 or 304L” and replace with “316 or 316L”.

Paragraph 2.2 MANUAL VALVES

Delete “Type 304 or”.

Paragraph 2.2.1 Ball Valves

Delete fifth sentence “Except as otherwise specified, reduced port or full port valves may be provided at the Contractor's option.” and replace with “Valves shall be full port.”

(End Summary of Changes)