Att 01 PWS Class B Uniforms OM.pdf
PDF 126 KB Posted
- Solicitation number
- N6264926QH009
About this file
This is a Performance Work Statement for Fire & Emergency Services, Joint Region Marianas, detailing requirements for the procurement of NFPA 1975-compliant flame-resistant uniforms. The contractor must provide 300 NOMEX IIIA Industrial Pants and 300 Short Sleeve Shirts (4.5 oz. NOMEX IIIA) in specified sizes for both men and women. The shirts are available in sizes 36 through 54 (regular) and women's sizes 30, 38, 44, 50, and 54, with quantities ranging from 3 to 80 units per size. The pants are available in waist-by-inseam combinations ranging from 30x30 to 50x32 for regular sizes and women's sizes 8x30, 10x31, and 16x28, with quantities between 3 and 36 units per size specification.
All garments must be manufactured to specific technical standards including 7.5 oz. NOMEX IIIA fabric for pants and durable flame-resistant NOMEX IIIA fabric for shirts, with features such as autoclaved permanent creases, brass hardware, double-stitched construction, and military creases. All items must be Navy Blue and certified to NFPA 1975 standards. Delivery is required within 120 calendar days after award to Building 1300, Joint Region Marianas Fire & Emergency Services, Camp Blaz, Forager Road, Dededo, Guam 96915. Items must be individually folded, packaged by garment type and size, and protected against moisture and damage, with exterior cartons clearly labeled with contract number, item description, size, and quantity. Inspection occurs at destination and acceptance is based on quantity, material compliance, correct sizing, overall workmanship, and packaging, with rejected items to be replaced at no additional cost. The technical point of contact is Tony T Borja, 671-355-9078, tony.t.borja.civ@us.navy.mil.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation - N6264926QH009.pdf | ||
| Addendum 01 52.212-1 Instructions OM.pdf | ||
| Addendum 02 52.212-2 Evaluation OM.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire & Emergency Services Joint Region Marianas
Performance Work Statement
1. Background
The National Fire Protection Association (NFPA) technical committee on Protective Equipment for
Firefighters began work on NFPA 1975 in response to requests from the fire service to establish requirements for flame-resistant station uniform clothing. NFPA 1975 is the standard that sets requirements for flame-resistant work apparel for emergency services personnel. Fire & Emergency
Services Joint Region Marianas has adopted the NFPA 1975 standard and established a Standard
Operating Procedure for station wear. Purchase of NFPA compliant uniforms is required for compliance.
2. Requirement
Provide for NOMEX IIIA Uniform Short Sleeve Shirt and NOMEX IIIA Industrial Pant
Quantity: 300 each NOMEX IIIA Industrial Pant
Quantity: 300 each Short Sleeve Shirt - 4.5 oz. NOMEX IIIA
SHIRT Quantity
36 4
38 12
40 26
42 60
44 80
46 30
48 52
50 12
52 3
54 3
30 Women 3
38 Women 3
44 Women 6
50 Women 3
54 Women 3
PANTS waist x inseam
Quantity
30x30 6
32x30 28
32x32 8
33x34 6
34x29 6
34x30 36
34x32 10
34x34 12
35x32 6
35x34 6
36x30 13
36x32 18
36x34 10
36x36 6
38x28 6
38x29 6
38x30 9
38x30 18
38x32 24
40x30 12
40x32 15
42x29 6
42x32 6
42x34 6
44x30 6
50x32 6
8x30 Women 3
10x31 Women 3
16x28 Women 3
3. Technical Specifications
NOMEX IIIA Industrial Pant
Made from 7.5 oz. Nomex IIIA Fabric.
Autoclaved for permanent creases
Solid brass nail button and zipper
Triple-felled stitching on outer and rear seams for durability
Fully finished waistband
Pockets include two front slash pockets and two rear welt pockets
Features a looser fit through the thighs and seat
Meets NFPA 1975 Standard
Navy Blue color
Short Sleeve Shirt - 4.5 oz. Nomex IIIA
Made with durable, flame-resistant Nomex IIIA fabric
Autoclaved for permanent creases
Two breast pockets with hook-and-loop flaps
Left pocket features a pencil slot and above it, a badge tab
Shoulder epaulets secured with Melamine buttons
Five sewn-in military creases
Collar band
Double-stitched to NFPA 1975 station uniform standard
Pressed and autoclaved
Certified to NFPA 1975 station uniform standard
Navy Blue color
4. Delivery Address:
Fire & Emergency Services
Building 1300
Dededo, Guam 96915
5. Required Delivery Date: 120 days after award
6. Quality Assurance The contractor shall maintain a quality control system that ensures all delivered items conform to contract requirements.
The Government reserves the right to inspect any shipment.
Items may be rejected for:
• Incorrect sizing
• Color variation
• Fabric defects
• Damage during shipment
Rejected items shall be replaced at no additional cost.
7. Packaging Items shall be:
• Individually folded
• Packaged by garment type
• Packaged by size
• Protected against moisture and damage
Exterior cartons shall clearly identify:
• Contract Number
• Item Description
• Size
• Quantity
8. Delivery Within 120 calendar days after award Delivery Location:
Fire & Emergency Services Joint Region Marianas Building 1300 Camp Blaz Forager Road, Dededo, Guam 96915
9. Inspection and Acceptance Inspection shall occur at destination.
Acceptance will be based upon:
• Quantity
• Material compliance
• Correct sizing
• Overall workmanship
• Packaging
Acceptance is subject to FAR 52.212-4.
10. Technical Point of Contact Tony T Borja.
PH: 671-355-9078
Email: tony.t.borja.civ@us.navy.mil
File details come from the government source that posted it. Updated .