CLASS "B" CONCRETE CONSTRUCTION
1/2" RADIUS
i--------
----r�-----��-�--<1----�-�
3/4" RADIUS
ROADWAY WIDTH TO THIS POINT
PAVEMENT
12"
<I
Ll
Ll
Ll
<I
Ll L'.l <I
Ll <I
Ll
Ll <I
Ll
<I
<I
Ll
<I
Ll
5:1 BATTER
3/4" RADIUS
Ll
<I
Ll
Ll <I
<I L'.l Ll
Ll
<I
Ll
PAVEMENT SHALL BE PLACED
3/8" ABOVE LIP OF GUTTER
<I
L'.l Ll
<ILl L'.l
<I
Ll Ll <I
L'.l
Ll
<I i-- -- - - - - - - - - - - - --24" -----------------
A.B.C. COMPACTED _/
TO 95% (MINIMUM) MINIMUM LONGITUDINAL GRADE = 0.20%
NOTES
1"
1. Vertical curb & gutter may be constructed by the use of forms or the concrete may be machine extruded.
2. When the pavement slopes away from the gutter, the slope of the gutter will match the pavement's cross slope. Gutter depression and 3/8" pavement above lip of gutter will not be needed.
3. Contraction joint spacing shall be either hand tooled and/or saw cut and shall be placed no further than ten feet (10') apart. Contraction joint shall have a minimum depth of two inches (2").
4. Expansion joints shall be located at tangent points, in curb returns, at structures and at a maximum of twenty foot (20') intervals. The one-half inch (1/2") joint filler material shall be the bituminous type meeting the A.A.S.H.T.O. M-33 or the A.S.T.M. D-1751 specifications and shall extend the full depth of the concrete.
5. Curb & gutter shall be finished with steel trowel followed by a longitudinal brush broom finish. All exposed edges and hand tooled joints shall have a one-quarter inch (1/4") radius unless a larger radius is called for in the construction plans.
6. City of Yuma vertical curb & gutter shall be used on ---------------------1 all city streets unless otherwise approved by the Issued: February 2009 City Engineer.
---------------------1
7. Additional information regarding joint construction can be seen in Standard Detail 3-270.
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-120
VERTICAL CURB AND GUTTER
________ _...,,__ ____ DRIVEWAY_.,.__-,..,__ __
WIDTH
�4.5' DRIVEWAY WINGS
SEE STANDARD 3-250
INSTALL EXPANSION JOINT WHEN CONNECTING TO
EXISTING OR NEW CONCRETE DRIVEWAY (ONLY) "A"
� i!: t�·5' M l
. tti; DRIVEWAY WIDTH AS PE� TABLE "A" rt 5' MIN. j
�o w H I I w H N � �
MAX. GRADE 12:1 (RUN:RISE) THROUGH WINGS
z
...I LO
ISL;:::PE
12 1 rn.J .
--i---r---
., · 4 • . .. . io l ;-. ,; .·· *�J r DEPRESSED CURB o, 1/2" EXPAN
NTS ··
.'! 4 .. . ·. ,:."
J /
WHEN DRIVEWAY WIDTH EXCEEDS 22' PROVIDE_/
EXPANSION JOINT ON DRIVEWAY CENTER LINE
I
BACK OF CURB _/
SECTION "A • A" TABLE "A"
CLASS "B" CONCRETE CONSTRUCTION
NOTES
1. Expansion joints shall be located at tangent points in curb returns, at structures and placed at 20' intervals (maximum). The one-half inch (1/2") joint filler shall be the bituminous type meeting A.A.S.H.T.O. M-33 or ASTM D-1751 specifications and shall extend the the full depth of the concrete.
2. Approved driveway locations can be found in Standard Detail 3-250.
DRIVEWAY WIDTHS MIN. MAX.
COMMERCIAL 16' 40'
INDUSTRIAL 16' 40'
RESIDENTIAL 16' 30'
Issued: February 2009
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-210
DRIVEWAY ENTRANCE WITH
SIDEWALK ADJACENT TO CURB
1/4" RADIUS
EACH SIDE
EXISTING CURB
6' - 10' MIN. WIDTH (MAJOR STREETS)
I r 5-0" MIN. WIDTH (LOCAL STREETS) T, VARIES --+------I
SLOPE 50:1
I
2"
AND GUTTER 7 j ,.- :-"�,r • .. �·- "�-· • · .
• ,!·:.: (� "6i.>�/ ·-�··:.-f I-,--------'Jr--...,...-'
' ._-,:,·,:·:\ FINISHED GRADE I r- - - - - -
I I L _______ _
·���v _/ 4" CLEAN SAND I A.B.C. COM- '«('<(w' RIGHT-OF WAY
PACTED TO 95% (MINIMUM) '(/"
� SUBGRADE COMPACTED
PREFERRED SIDEWALK LOCATION TO 95% (MINIMUM)
FINISHED PARKWAY
VARIES
5'-0" MIN. WIDTH (LOCAL STREETS) 1
,, -I
GRADE " 6'- 1 O' MIN. WIDTH (MAJOR STREETS)
I " 1/4" RADIUS
EXISTING CURB � EACH SIDE SLOPE 50.1 I AND GUTTER
j "" ·
/1 I 2" MAX.
f-=-=--�./ I I I
CONTRACTION JOINT
">' .;:, .,:·_,, ···:��;�:«Y«Y/,<Y«/;
CLEAN SAND / AB.C. coJ j</'0�>,:::<""'-<,.;'::<.
PACTED TO 95% (MIN.)
/ RIGHT-OF WAY
SUBGRADE COMPACTED
TO 95% (MINIMUM)
ALTERNATE SIDEWALK LOCATION
SHALL BE FINISHED � 1 1/2" (MIN.) DEPTH 111/2"
2"
TO A WIDTH OF 1/4" MAX� j_ _ju
-1/-4'-'R-/�I' 1/4"R
1/4"R TYPICAL T EXPANSION JOINT
___ 20' (MAX.) BETWEEN EXPANSION JOINTS --------
---· 1
5' LOCAL STREETS
TROWEL AND LIGHT BROOM 6'-10' MAJOR STREETS FINISH TRANSVERSE TO TRAFFIC
5' LOCAL STREETS
6'-10' MAJOR STREETS
ALL SIDEWALKS: 4" (MIN.) CLASS "B" CONCRETE CONSTRUCTION
NOTES
1. Expansion joints shall be located at tangent points, in curb returns, at structures and placed at 20' intervals (maximum). The one-half inch (1/2") joint filler shall be the bituminous type meeting A.A.S.H.T.O. D-1751 specifications and shall extend the full depth of the concrete.
2. Expansion joint material shall be placed between curb & gutter and sidewalk when the back of the sidewalk abuts concrete driveways, other concrete paving or structures.
Issued: February 2009
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-270
SIDEWALKS
SIDEWALK WHERE SHOWN ON PLANS
� 45° UNLESS DIRECTED OTHERWISE
I "' "' BY THE CITY ENGINEER
SEE NOTE NO. 3 FOR
RADIUS DIMENSIONS
(MEASURED TO FACE OF CURB)
1/4" DEEP GROOVES AT 1"
O.C.; FULL FACE OF RAMP
TOP OF CURB LEVEL
ROUGH
BROOM
FINISH
l WITH BACK OF ADJA
CENT SIDEWALK
DETECT BLE WARNING STRIP
(SEE STD. NO. 3-291) --y-�����.;::,.;_�'A
� LIP OF GUTTER
DEPRESSED CURB
FLOWLINE OF GUTTER
SIDEWALK
WHERE
SHOWN
ON PLANS T.0.C.= TOP OF CURB HEIGHT
ABOVE GUTTER FLOWLINE
VERTICAL CURB & GUTTER
I
CONSTRUCTION JOINT
DETECTABLE WARNING STRIP
(SEE STD. NO. 3-291 Sheet 2)
EXPANSION
JOINT (TYP.) TOP OF CURB LEVEL r (5'-6" MIN. WIDTH
::i
WITH BACK OF ADJA- \
CENT SIDEWALK L \_ 4" CONCRETE SIDEWALK
-50:1MAX
f
� . '1 .• <I� .to .q
NOTES J
� .. 4 •
�-. ·· ,i_ .il. � _..to:: .. �-· ·. ·..to. �- .: :-" �- ... 4'Y:z' ·,.,> .'"i';•· ... "·>:·.:.::.:<,.·. • ....... "·•· ··,,·· :,-
···· .... ·LI·
. 4
1. FOR COLLECTORS, ARTERIALS AND AREA
<�)0y���)», ,;_y' ·7
SERVICE HIGHWAYS PLACE RAMP AT EACH , <"<<'-'</•' //,'< CROSSWALK LOCATION, IN ACCORDANCE SUBGRADE COMPACTED WITH A.DA REQUIREMENTS. TO 95% (MIM.) 2 .. TO 10" A.B.C. UNDER 2. CONSTRUCT WITH CLASS "B" CONCRETE. 4,, (MIN.) CLEAN SAND / A.B.C. CURB & GUTTER DEPEND-3. RADIUS REQUIREMENTS (FACE OF CURB): COMPACTED TO 95% (MIN.) ING ON TYPE OF STREET A. LOCAL STREET: 25' MINIMUM
B. COLLECTOR STREETS: 40' MINIMUM SECTION 11A•A11
C. ARTERIAL STREETS: 50' MINIMUM
D. SERVICE HIGHWAYS: 50' MINIMUM
4. EXPANSION JOINTS SHALL BE LOCATED AT TAN
GENT POINTS IN CURB RETURNS, AT STRUCTURES
AND AT A MAXIMUM 20 FOOT INTERVAL. THE ONE
HALF INCH JOINT FILLER SHALL BE THE BITUMINUS
TYPE MEETING A.A.S.H.T.O. M-33 OR THE A.S.T.M.
D-1751 SPECIFICATIONS AND SHALL EXTEND THE
FULL DEPTH OF THE CONCRETE.
5. BACK OF CURB AND GUTTER SHALL BE
DEPRESSED (NO LIP)
Issued: February 2009 Sheet 1 of2
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-280
SIDEWALK RAMP
4.0'-5.0'
:.i N I-
0 ENLARGED DETAIL
DETECTABLE WARNING
STRIP PLAN VIEW (TRUNCATED)
DETECTABLE WARNING STRIP
(SEE STD. NO. 3-292)
SIDEWALK
WHERE
SHOWN
ON PLANS
TEXTURE PATTERN DETAIL
_L_j \0.45"
@ l 0.2" l"-..._-___/I
TRUNCATED DOME
DETAIL
I-- 6'MIN. 2.5' 2.5'
MIN. i MIN.
6' MIN. --I
SIDEWALK RAMP
STRAIGHT SECTION
NOTES:
TOP OF CURB LEVEL
WITH BACK OF ADJA
CENT SIDEWALK
1. SEE STD. DETAIL NO. 3-291 Sh. 2 of 2 FOR
ADDITIONAL DETAILS ON DETECTABLE
WARNING STRIP
LIP OF GUTTER
DEPRESSED CURB
DETECTABLE WARNING STRIP
(SEE STD. NO. 3-291 Sh. 2 of 2)
SIDEWALK RAMP
CURB SECTION
Issued: February 2009 Sheet 1 of 2
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-291
DETECTABLE WARNING STRIP
48.000" 14 SPACES OUT TO
1.050" 28 DOMES @ 1.670" 0/C 1.050" 3 OO" OUT @ 3.00" 0/C 3 OO"
..._,.........-DETAIL-1
\ A 11 · 0.625" TYP.
• 1 r .................... -...... _______ .,.... ...... _....., @@@@@@@@@@@@@@@@@@@@@@@@@@@@ N
@@@@@@@@@@@@@@@@@@@@@@@@@@@@ ID
N
A@@@@@@@@@@@@@@@@@@@@@@@@@@@@ A
A
PLAN
0.625" DIA. HOLES
THROUGH EMBEDMENT
FLANGES
0.1875" DIA. x 0.0625"
HIGH MICRO-TEXTURE
UNDER-SIDE OF TILE
REFLECTED PLAN
1.2625" 0.625" HOLE THROUGH EMBEDMENT 1.2625" =
0.625"
INTERNAL EMBEDMENT
FLANGE 15 PER TILE
= n 1.670" n
FLANGES AS SHOWN IN REFLECTED 1 6�0" TYP
� I �
LL_
np· PLAN CENTERED TYP.
·l i l_j � o,�m��NT L HOLE (ONE PER
J L CELL EACH SIDE)
0·1875,, SECTION A-A
io N (0
90° POINTS
0.045" HIGH
0.625" DIA. HOLE
EMBEDMENT FLANGES
AS SHOWN IN
REFLECTED PLAN
INTERNAL EMBEDMENT
FLANGE @2 3" 0/C (SEE
PLAN FO�ORIENTATION)
\_ NOTE: OPTIONAL
SOUND AMPLIFYING
PLATE ADDED BY
MANUFACTURER
SECTION B-B
1.050" 1.670" TYP.
00000 000000000 000 00000 000000000 000
00 ggg
O
00 0
NOTE:
c::i D
'SI"
c::i D
0.09375" _Wj FIELD LEVEL
MICRO-TEXTURE
DETAIL 1
41 POINTS PER
SQUARE INCH
NOTES
1. ADA Solutions, lnc.,Trekway Dome Tiles and Rampdome systems are approved commercial products.
2. The approved items are not necessarily exclusive. If a similar product of comparable and equal quality and performance is desired, a request supported by appropriate information and data may be submitted to the City Engineer for review.
3. Embedments shall be as per manufacturers recommendations.
Issued: February 2009 Sheet 2 of 2
CITY OF YUMA
CONSTRUCTION STANDARD DETAIL DRAWINGS
STANDARD NO. 3-291
DETECTABLE WARNING STRIP