L-VT04 Additional Ind Questions-Gov Response 22-24.docx
DOCX document 14 KB Posted
- Solicitation number
- N61331-22-T-VT04
About this file
This document contains an industry questions and government response sheet as well as a federal contract opportunity solicitation. The Naval Surface Warfare Center Panama City Division requires contractor services to design, assemble, and install an advanced video surveillance system for the Ocean Simulation Facility located at the Navy Experimental Dive Unit. The system must offer operator control, functionality, viewing capacity, and ease of future expansion. It will include replacement of existing cameras, displays, control systems, routing and processing technology, recording devices, cabling, and chamber penetrations. All equipment must be NDAA and TAA compliant. The response deadline is 14 February 2022. The opportunity is set aside for small businesses only with a North American Industry Classification System code of 334310 and size standard of 750 employees.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| L-VT04 Additional Ind Questions-Gov Response 18-21.docx | DOCX document | |
| C-CDRL VideoSurveillanceSystem.docx | DOCX document | |
| Site Visit Questions.pdf | ||
| L- VT04 Ind Questions-Gov Response.docx | DOCX document | |
| CLAUSES.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N61331-22-T-VT04
Industry Questions and Government Response
Continuation Sheet 1/25/2022
22. Will the Wet Pot Chamber ever be pressurized without water? Ie; will any of our underwater equipment be in a pressurized without being submerged in water?
Gov Response: The only time the Wet Pot is pressurized without water is for off-gas testing (e.g. after painting the Wet Pot every 5 years or various large equipment). The off-gas testing doesn’t go below 200 fsw, ~ 90 psi.
0. Follow up question if the answer is yes: Is NEDU willing to remove our underwater equipment during this situation?
Gov Response: If the system is NOT capable of being pressurized without water, NEDU would be willing to remove equipment if necessary.
23. Will the Dry Chambers ever be a pure oxygen environment?
Gov Response: No, maximum theoretical O2 content will never exceed 23%.
24. Have we extended the due date past February 4th?
Gov Response: Due to requests, the due date will be extended to 14 Feb 2022.