N4523A18R1054_RFC_005.pdf

PDF 34 KB Posted

Attached to
Maintenance, Preservation, and Repair SWOB-8
Solicitation number
N4523A18R1054
Issued by

About this file

N4523A18R1054 RFC 005

View the file

Other files

File Type Posted
N4523A18R1054_RFC_008.pdf PDF
N4523A18R1054_Amendment_4_SWOB-8.pdf PDF
N4523A18R1054_SWOB-8__Updated_Attachment_J-2__5-Way_breakout_24MAY2018.xls XLS spreadsheet
N4523A18R1054_RFC_004.pdf PDF
N4523A18R1054_Amendment_3_SWOB-8.pdf PDF
N4523A18R1054_RFC_006.pdf PDF
N4523A18R1054_RFC_007.pdf PDF
N4523A18R1054_RFC_003.pdf PDF
N4523A18R1054_SWOB-8__Updated_Attachment_J-2__5-Way_breakout_21MAY2018.xls XLS spreadsheet
N4523A18R1054_RFC_002.pdf PDF
N4523A18R1054_Updated_Attachment_J-1_SWOB-8_SOW_Errata_One.pdf PDF
N4523A18R10540002_SWOB-8_Amendment_0002.pdf PDF
N4523A18R1054_RFC_001.docx DOCX document
N4523A18R1054_Exhibit_A_CDRLS_&_DIDs_SWOB-8_30APR2018.zip ZIP file
N4523A18R10540001_SWOB-8_Amendment_0001.pdf PDF
N4523A18R1054_Attachment_J-6_References_SWOB-8_.zip ZIP file
N4523A18R1054_Attachment_J-4_Contract_Performance_Data_Sheet.docx DOCX document
N4523A18R1054_Attachment_J-3_Request_for_Clarification_(RFC)_Form.docx DOCX document
N4523A18R1054_Attachment_J-5_Corporate_Experience_Data_Sheet.docx DOCX document
N4523A18R1054_Exhibit_A_CDRLS_&_DIDs_SWOB-8.zip ZIP file
N4523A18R1054_Attachment_J-1_Statement_of_Work__SWOB-8_4APR18.pdf PDF
N4523A18R1054_SWOB-8_Solicitation_26APR2018.pdf PDF
N4523A18R1054_Attachment_J-2_SWOB-8_5-way_Breakdown.xls XLS spreadsheet
N4523A18R1054_DRAFT_SOW_SWOB-8_updated_4APR18.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR SPECIFICATION CLARIFICATION

DATE OF REQUEST: 21MAY2018 QUESTION NO: 005

REQUIREMENT: N/A REQUISITION NO.: N4523A18R1054

ITEM NO: N/A

TITLE: RUBBER FENDERS

ISSUING OFFICE POC (CODE 440.22):

Brittany Chartier: (360) 476-5708 Brittany.chartier@navy.mil

PARA. NO: 3.2.2 PAGE NO: 23, SOW CONTRACTOR:

PLANNER’S NAME: ATTACH. NO: CONTRACTOR POC & PHONE:

CONTRACTOR QUESTION:

1. If the contractor is to replace the mounting hardware for the rubber fenders, what is the size and quantity required?

DO NOT WRITE BELOW THIS LINE

SPEC CHG: Y/N DWG/REF CHG. Y/N RQMTS CHG: Y/N MAT'L CHG: Y/N

TECHNICAL REVIEW: E. Baxter SERIAL NO: 005

Please see Paragraph 3.2.2.4 in the updated Statement of Work Errata one (Attachment J-1). It is included in Amendment 0003 of the solicitation posted to FBO.GOV.

ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING OFFICE POC NO

LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST FOR PROPOSAL.