This document is a construction drawing for plumbing work at Fleet Readiness Center East, Building 4035 basement. The drawing is identified as Plumbing Plan - Construction (P-101), dated 31 AUG 2026, issued for bid, with drawing number 12939831. The project involves two primary tasks: replacing mechanical seals per Detail A1 and repairing pipe penetration seals per Detail A3.
The work requires installation of a new modular pipe sealing system for 4-inch ductile iron and gray PVC pipes that penetrate the sump concrete wall. The mechanical seal replacement specifies removal of existing sealing elements, cleaning of sleeve and pipe surfaces, and installation of a new system with nitrile green rubber seal elements, reinforced nylon polymer pressure plates, and 316 stainless steel hardware, installed per manufacturer's instructions. The pipe penetration seal repair requires removal of existing sealing materials, enlargement of clearance around pipes, surface preparation including filing concrete to a smooth finish, and application of a chemical resistant fluoroelastomeric sealant suitable for chromate and cyanide waste compatibility. A 3/4-inch diameter backer rod is specified for the cavity around pipes. The plumbing floor plan identifies three waste tanks (Acid Waste T-401, Chromate Waste T-402, and Cyanide Waste T-403) with corresponding pipe runs requiring seal work. All dimensions shown are approximate, and field verification is required prior to ordering materials and commencing work. This drawing forms part of Work Order #7516334.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 7516334 Amendment 0002.pdf | ||
| 7516334 Amendment 0001.pdf | ||
| 7516334 STREAMLINE SOW.pdf | ||
| FRCE Access Letter Format Example.docx | DOCX document | |
| 7516334 Master PPI Form.xlsx | XLSX spreadsheet | |
| 7516334 RFP.pdf | ||
| 7516334 MACC.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACID WASTE
T-401
CHROMATE
WASTE
T-402
CYANIDE
WASTE
T-403
A
A3
P-101
A3 P-101
A1 P-101
(ETR) PIPE - 4" DUCTILE IRON
PROVIDE NEW MODULAR PIPE SEALING SYSTEM.
NITRILE GREEN RUBBER SEAL ELEMENT, REINFORCED
NYLON POLYMER PRESSURE PLATES, 316 STAINLESS
STEEL HARDWARE. INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
SUMP CONCRETE WALL
RE-USE EXISTING NON METALLIC, HIGH
DENSITY POLYETHYLENE WALL SLEEVE
A1 DETAIL - MECHANICAL SEAL
NOT TO SCALE
REMOVE EXISTING SEALING ELEMENT. CLEAN SLEEVE
AND PIPE SURFACES TO A SMOOTH FINISH FOLLOWING
MANUFACTURER'S RECOMMENDATIONS.
(ETR) PIPE - 4" GRAY PVC
A3 DETAIL - PIPE PENTRATION SEAL REPAIR
NOT TO SCALE
EXISTING TO REMAIN
NEW
1. THIS DRAWING FORM PART OF WORK ORDER #7516334 AND SHALL NOT BE
INTERPRETED AS A STAND ALONE DOCUMENT.
2. DIMENSIONS SHOWN ARE AN APPROXIMATE. FIELD VERIFY ALL DIMENSIONS
PRIOR TO ORDERING MATERIALS AND COMMENCING WORK .
3. REMOVAL OF ITEMS MUST INCLUDE ASSOCIATED SUPPORTS, ANCHOR
BOLTS AND OTHER APPURTENANCES.
REPAIR PIPE PENETRATION SEAL PER DETAIL A3 ON THIS
DRAWING.
REPLACE MECHANICAL SEAL PER DETAIL A1 ON THIS
DRAWING.
N
B4035 WORK LOCATION
SCALE: NOT TO SCALE
WORK LOCATION
(BASEMENT)
N
PLUMBING FLOOR PLAN - CONSTRUCTION
SCALE: 1/2" = 1' - 0"
0 1' 1/2" = 1'-0"
4'
O .D
O .D
" M
IN
REMOVE EXISTING SEALING MATERIALS COMPLETEY.
ENLARGE CLEARANCE AROUND PIPE AS INDICATED.
WIPE CLEAN PIPE USING MINERAL SPIRITS.
FILE CONCRETE SURFACE TO SMOOTH FINISH
SURFACE PREPERATION
FULLY FILL CAVITY AROUND PIPE USING A CHEMICAL RESISTANT
FLUOROELASTOMERIC SEALANT SUITABLE FOR CHROMATE AND CYANIDE.
3/4 Ø BACKER ROD
SUMP CONCRETE WALL
(TYP. FOR 3)
GENERAL NOTES
LEGEND AND ABBREVIATIONS
KEY NOTES
FL
E
E T
R E
A D
IN
E
S S
C E
N
TE
R E
A S
T
R E
P
LA
C E
P
IP
E S
E A
LS
B
A S
E M
E N
T B
U
IL
D
IN
G
31 AUG 2026
FINAL
ISSUED FOR BID
P-101
PL
U
M
BI
N G
P
LA
N
C O
N
ST
R U
C
TI
O N
12939831
AS NOTED
J. PADRO
J. PADRO
J. PADRO
AutoCAD SHX Text
DEPARTMENT OF THE NAVY
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
CONSTR. CONTR. NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
DES
AutoCAD SHX Text
DRW
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPR
AutoCAD SHX Text
DRAWFORM REVISION: 16 MAY 2024
AutoCAD SHX Text
CHK
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
OF
AutoCAD SHX Text
CP FEAD WO:
AutoCAD SHX Text
FRCE WO:
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FAC PLAN PROJ NO:
AutoCAD SHX Text
SHOP:
AutoCAD SHX Text
CAGE CODE:
AutoCAD SHX Text
FACILITIES AND PLANT PLANNING DIVISION
AutoCAD SHX Text
MCAS CHERRY POINT, NC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
J. LUPTON
AutoCAD SHX Text
J. PADRO
AutoCAD SHX Text
PE-21323
AutoCAD SHX Text 7516334
AutoCAD SHX Text
XF29135
AutoCAD SHX Text 31330
AutoCAD SHX Text 96916
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .