Amendment 01.pdf
PDF 539 KB Posted
- Attached to
- FIRE SUPPRESSION SUPPORT
- Solicitation number
- N40085-26-R-0052
About this file
This is Amendment 0001 to Solicitation N40085-26-R-0052, an Indefinite Delivery Indefinite Quantity (IDIQ) contract amendment issued by NAVFACSYSCOM Mid-Atlantic on April 27, 2026, with an effective date of April 27, 2026. The amendment adds Attachment J-0200000-06 Proposal Pricing to Section J (List of Attachments) and does not extend the offer receipt date. The solicitation number is N40085-26-R-0052, dated April 25, 2026. The contractor must acknowledge receipt of this amendment by completing items 8 and 15, acknowledging receipt on each copy of the offer submitted, or submitting a separate letter or electronic communication referencing the solicitation and amendment numbers prior to the hour and date specified for offer receipt.
The contract pertains to fire suppression and pump services maintenance across multiple naval facilities. Services include annual testing and routine integrated maintenance programs for monitored fire detection and alarm systems, wet pipe sprinkler systems, pre-action automatic sprinkler systems, clean agent systems, carbon dioxide systems, and fire and smoke barrier opening protection. The contract covers 26 base buildings and 9 Department of Defense (DoD) school facilities. Pricing is structured in two categories: recurring firm fixed-price items (Spec Item 3) for annual maintenance services, and non-recurring unit-priced labor and materials items (Spec Item 4) with an annual IDIQ not to exceed $165,000. Contractors must provide labor rates for unit-priced labor measured in labor hours (LH), with estimated material costs provided on a lump-sum (LS) basis. The contract includes optional extension periods at 1-month, 3-month, and 6-month intervals, with extended service pricing calculated as proportional costs of the base option services.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0003.pdf | ||
| Amend 0002.pdf | ||
| Revised J-02000000-06 ELINS Pricing.pdf | ||
| Solicitation N4008526R0052 1.pdf | ||
| SOL N4008526R0052.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
16C. DATE SIGNED
Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBE
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
Created On:
27 Apr 2026, 10:57 AM Greenwich Mean Time
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
Section J - List of Attachments
The following attachments were added:
J-0200000-06 Proposal Pricing
N4008526R00520001
Provide Pricing to Maintain Fire Suppression and Pump Services for the Firm Fixed Price for recurring Spec Items in accordance with Section C, Spec Item 3.
ELIN /
Sub ELIN
Description Quantity Freq Unit of Issue
Unit Price Total
Building - AS256 (BASE)
A00101 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00102 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00103 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00104 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00105 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
A00106 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
A00107 Develop and Implement a Routine Intergrated Maintenace Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00108 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - AS320 Simulator (BASE)
A00109 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00110 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00111 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00112 Implement Annual Testing on Carbon Dioxide Systems.
1 A EA
A00113 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00114 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A00115 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00116 Develop and Implement a Routine Integrated Maintenance Program on a Carbon Dioxide Systems.
1 A EA
Building - TC755 (BASE)
A00117 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00118 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00119 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A00120 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00121 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
A00122
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
Building - 895 (BASE)
A00123 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00124 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00125 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00126 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00127 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A00128 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - BB248 (BASE)
A00129 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
A00130 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00131 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00132 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00133 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00134 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building- FC307 (BASE)
A00135 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00136 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00137 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00138 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
Building - H1 (BASE)
A00139 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
A00140 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00141 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
A00142 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00143 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00144 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00145 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A00146 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
A00147 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00148 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
Building - HP5 (BASE)
A00149 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00150 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00151 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00152 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00153 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00154 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - M165 (BASE)
A00155 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00156 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00157 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00158 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - PP5 (BASE)
A00159 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
A00160 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00161 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00162 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00163 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00164 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
Building - RR134 (BASE)
A00165 and Alarm Systems.
1 A EA
A00166 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00167 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00168 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - 1043 (BASE)
A00169 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00170 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00171 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00172
Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
A00173 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
A00174 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
Building - WC99 (BASE)
A00175 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00176 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00177
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00178 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - WC507 (BASE)
A00179 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00180 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00181 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00182 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
A00183 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
A00184 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - 24 (BASE)
A00185 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00186 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00187 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
A00188 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
A00189 Implement Annual Testing on Clean Agent Systems. 1 A EA
A00190
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00191 Develop and Implement a Routine Integrated
A00192
Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
A00193 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
A00194 Develop and Implement a Routine Integrated
Building - 835 (DoD Schools)
A00195 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A00196 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A00197 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A00198
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A00199 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001AA
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 855 (DoD Schools)
A001AB
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A001AC
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001AD
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
Building - 883 (DoD Schools)
A001AE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A001AF
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001AG
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A001AH
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001AJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001AK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
Building- 2027 (DoD Schools)
A001AL
and Alarm Systems.
1 A EA
A001AM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001AN
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A001AP
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001AQ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001AR
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier
Building - 2028 (DoD Schools)
A001AS Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A001AT
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001AU
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A001AV
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001AW Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001AX
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - PP201 (DoD Schools)
A001AY
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A001AZ
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001BA
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
A001BB
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001BC
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001BD
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - TT84 (DoD Schools)
A001BE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
A001BF
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001BG
Implement Annual Testing on Fire and Smoke Barrier
A001BH
Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001BJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
A001BK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - AS990 (DoD Schools)
A001BL
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
A001BM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
A001BN
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
A001BP
Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
DoD School Totals
Contract Annual Total
PROPOSAL PRICING
SOLICITATION/CONTRACT N40085-26-R-0052
Provide Pricing to Maintain Fire Suppression and Pump Services for the Firm Fixed Price non-recurring Spec Items in accordance with Section C, Spec Item 4.
(The total-yearly IDIQ for each year will Not Exceed $165,000.00, contractors must provide their Labor Rate)
ELIN Product Name Description Extended Estimated Quantity
Unit of
Issue
Unit Price Extended Price
A00201 Unit Priced Labor Provide labor - Contractor Must provide Labor Rate
LH
A00202 Material Costs Provide all materials and equipment to perform Unit Priced Labor.Per each Task Order. (NTE extended price per year)
LS
TOTAL AMOUNT OF TASK ORDERS WILL NOT
EXCEED INDEFINITE QUANTITY PER YEAR
Firm Fixed Price for recurring Spec Items in accordance with Section C, Spec Item 3.
ELIN /
Sub ELIN
Description Quantity Freq Unit of Issue
Unit Price Total
Building - AS256 (BASE)
B00301 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00302 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00303 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00304 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00305 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
B00306 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
B00307 Develop and Implement a Routine Intergrated Maintenace Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00308 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - AS320 Simulator (BASE)
B00309 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00310 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00311 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00312 Implement Annual Testing on Carbon Dioxide Systems.
1 A EA
B00313 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00314 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B00315 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00316 Develop and Implement a Routine Integrated Maintenance Program on a Carbon Dioxide Systems.
1 A EA
Building - TC755 (BASE)
B00317 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00318 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00319 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B00320 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00321 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
B00322
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier
B00323 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00324 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00325 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00326 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00327 Develop and Implement a Routine Integrated
B00328 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - BB248 (BASE)
B00329 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
B00330 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00331 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00332 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00333 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00334 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building- FC307 (BASE)
B00335 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00336 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00337 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00338 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - H1 (BASE)
B00339 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
B00340 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00341 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
B00342 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
B00343 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00344 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00345 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B00346 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
B00347 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00348 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - HP5 (BASE)
B00349 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00350 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00351 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00352 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00353 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00354 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - M165 (BASE)
B00355 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00356 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00357 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00358 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - PP5 (BASE)
B00359 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
B00360 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00361 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00362 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00363 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00364 Develop and Implement a Routine Integrated
B00365 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00366 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00367 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00368 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - 1043 (BASE)
B00369 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00370 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00371 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00372
Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
B00373 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
B00374 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - WC99 (BASE)
B00375 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00376 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00377
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00378 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - WC507 (BASE)
B00379 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00380 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00381 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00382 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
B00383 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
B00384 Develop and Implement a Routine Intergrated
Building - 24 (BASE)
B00385 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00386 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00387 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
B00388 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
B00389 Implement Annual Testing on Clean Agent Systems. 1 A EA
B00390
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00391 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B00392 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
B00393 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
B00394 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - 835 (DoD Schools)
B00395 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B00396 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B00397 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B00398
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B00399 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003AA
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 855 (DoD Schools)
B003AB
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003AC
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003AD
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
Building - 883 (DoD Schools)
B003AE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003AF
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003AG
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B003AH
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003AJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003AK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier
B003AL
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003AM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003AN
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B003AP
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003AQ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003AR
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 2028 (DoD Schools)
B003AS Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003AT
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003AU
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B003AV
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003AW Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003AX
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - PP201 (DoD Schools)
B003AY
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003AZ
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003BA
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B003BB
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003BC
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003BD
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - TT84 (DoD Schools)
B003BE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
B003BF
Implement Annual Testing on Wet Pipe Sprinkler Systems.
B003BG
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
B003BH
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003BJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
B003BK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - AS990 (DoD Schools)
B003BL
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
B003BM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
B003BN
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
B003BP
Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
DoD School Totals
Provide Pricing to Maintain Fire Suppression and Pump Services for the Firm Fixed Price non-recurring Spec Items in accordance with Section C, Spec Item 4.
(The total-yearly IDIQ for each year will Not Exceed $165,000.00, contractors must provide their Labor Rate)
ELIN Product Name Description Extended Estimated Quantity
Unit of Issue
Unit Price Extended Price
B00401 Unit Priced Labor Provide labor - Contractor Must provide Labor Rate
1,000 LH
B00402 Material Costs Provide all materials and equipment to perform Unit Priced Labor.Per each Task Order. (NTE extended price per year)
100,000 LS
Firm Fixed Price for recurring Spec Items in accordance with Section C, Spec Item 3.
ELIN /
Sub ELIN
Description Quantity Freq Unit of Issue
Unit Price Total
Building - AS256 (BASE)
C00501 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00502 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00503 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00504 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00505 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
C00506 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
C00507 Develop and Implement a Routine Intergrated Maintenace Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00508 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - AS320 Simulator (BASE)
C00509 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00510 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00511 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00512 Implement Annual Testing on Carbon Dioxide Systems.
1 A EA
C00513 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00514 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C00515 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00516 Develop and Implement a Routine Integrated Maintenance Program on a Carbon Dioxide Systems.
1 A EA
Building - TC755 (BASE)
C00517 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00518 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00519 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C00520 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00521 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
C00522
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier
C00523 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00524 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00525 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00526 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00527 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C00528 Develop and Implement a Routine Integrated
Building - BB248 (BASE)
C00529 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
C00530 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00531 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00532 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00533 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00534 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building- FC307 (BASE)
C00535 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00536 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00537 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00538 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - H1 (BASE)
C00539 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
C00540 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00541 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
C00542 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
C00543 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00544 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00545 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C00546 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
C00547 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00548 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - HP5 (BASE)
C00549 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00550 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00551 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00552 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00553 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00554 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - M165 (BASE)
C00555 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00556 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00557 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00558 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - PP5 (BASE)
C00559 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
C00560 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00561 Implement Annual Testing on Clean Agent Systems. 1 A EA
C00562 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00563 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00564 Develop and Implement a Routine Integrated
C00565 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00566 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00567 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00568 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - 1043 (BASE)
C00569 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00570 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00571 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00572
Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
C00573 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
C00574 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - WC99 (BASE)
C00575 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00576 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00577 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00578 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
Building - WC507 (BASE)
C00579 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00580 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00581 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00582 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
C00583 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
C00584 Develop and Implement a Routine Intergrated
C00585 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00586 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00587 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
C00588 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
C00589 Implement Annual Testing on Clean Agent Systems.
1 A EA
C00590
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00591 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C00592 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
C00593 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
C00594 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - 835 (DoD Schools)
C00595 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C00596 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C00597 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C00598
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C00599 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005AA
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 855 (DoD Schools)
C005AB
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005AC
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005AD
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
Building - 883 (DoD Schools)
C005AE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005AF
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005AG
Implement Annual Testing on Fire and Smoke Barrier
C005AH
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005AJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005AK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier
C005AL
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005AM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005AN
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C005AP
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005AQ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005AR
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 2028 (DoD Schools)
C005AS Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005AT
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005AU
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C005AV
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005AW Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005AX
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - PP201 (DoD Schools)
C005AY
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005AZ
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005BA
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C005BB
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005BC
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005BD
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - TT84 (DoD Schools)
C005BE
Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
C005BF
Implement Annual Testing on Wet Pipe Sprinkler
C005BG
Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
C005BH
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005BJ
Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
C005BK
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - AS990 (DoD Schools)
C005BL
Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
C005BM
Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
C005BN
Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
C005BP
Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
DoD School Totals
Provide Pricing to Maintain Fire Suppression and Pump Services for the Firm Fixed Price non-recurring Spec Items in accordance with Section C, Spec Item 4.
(The total-yearly IDIQ for each year will Not Exceed $165,000.00, contractors must provide their Labor Rate)
ELIN Product Name Description Extended Estimated Quantity
Unit of Issue
Unit Price Extended Price
C00601 Unit Priced Labor Provide labor - Contractor Must provide Labor Rate
1,000 LH
C00602 Material Costs Provide all materials and equipment to perform Unit Priced Labor.Per each Task Order. (NTE extended price per year)
100,000 LS
Firm Fixed Price for recurring Spec Items in accordance with Section C, Spec Item 3.
ELIN /
Sub ELIN
Description Quantity Freq Unit of Issue
Unit Price Total
Building - AS256 (BASE)
D00701 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00702 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
D00703 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
D00704 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00705 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems.
1 A EA
D00706 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems.
1 A EA
D00707 Develop and Implement a Routine Intergrated Maintenace Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
D00708 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems.
1 A EA
Building - AS320 Simulator (BASE)
D00709 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00710 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
D00711 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
D00712 Implement Annual Testing on Carbon Dioxide Systems.
1 A EA
D00713 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00714 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
D00715 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
D00716 Develop and Implement a Routine Integrated Maintenance Program on a Carbon Dioxide Systems.
1 A EA
Building - TC755 (BASE)
D00717 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00718 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00719 Implement Annual Testing on Fire and Smoke Barrier Opening Protection.
1 A EA
D00720 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm
D00721 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
D00722
Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection.
1 A EA
Building - 895 (BASE)
D00723 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00724 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
D00725 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00726 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00727 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
D00728 Develop and Implement a Routine Integrated
Building - BB248 (BASE)
D00729 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA
D00730 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
D00731 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00732 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00733 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
D00734 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building- FC307 (BASE)
D00735 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00736 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00737 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00738 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - H1 (BASE)
D00739 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
A EA
D00740 Implement Annual Testing on Wet Pipe Sprinkler Systems.
1 A EA
D00741 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems.
1 A EA
D00742 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
D00743 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00744 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00745 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems.
1 A EA
D00746 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems.
1 A EA
D00747 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
D00748 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - HP5 (BASE)
D00749 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00750 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems.
1 A EA
D00751 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00752 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00753 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems.
1 A EA
D00754 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems.
1 A EA
Building - M165 (BASE)
D00755 Implement Annual Testing on Monitored Fire Detection and Alarm Systems.
1 A EA
D00756 Implement Annual Testing on Clean Agent Systems. 1 A EA
D00757 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems.
1 A EA
D00758 Develop…