N4008524B0044 Dwgs.pdf
PDF 31 MB Posted
- Attached to
- Roof Repairs Building 1445
- Solicitation number
- N4008525R9005
About this file
This document is a comprehensive set of architectural drawings for roof repairs at Building 1445, Marine Corps Base Camp Lejeune, North Carolina. The project involves a complete roof replacement, including removing the existing modified bitumen roofing system, installing a new roof deck air and moisture barrier, rigid insulation, and modified bitumen roofing system. The drawings specify detailed requirements for demolition, construction sequencing, and specific installation methods, with particular attention to maintaining building functionality during the project.
Key technical specifications include installing new roof components with a total R-value of 34.0, replacing roof drains, mechanical equipment curbs, and expanding joint flashings, and ensuring minimal disruption to the operational building. The construction sequence mandates careful planning, with work to be completed in phases, rooftop equipment downtime limited to 24 hours, and strict requirements for daily work progress, including only removing as much roofing as can be dried-in each day. The project is being conducted by the Department of the Navy Naval Facilities Engineering Command, with solicitation number N4008525R9005, and is limited to roofing MACC Contractors listed in the general requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 01 30 00.pdf | ||
| 07 52 00.pdf | ||
| Amend 0003 259005.pdf | ||
| Submittal Register.pdf | ||
| Amend 0002 240044.pdf | ||
| Amend 0001 24-0044.pdf | ||
| 240044 Basis of Design.pdf | ||
| RFP pdf.pdf | ||
| N4008524B0044 Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MCB Camp Lejeune and MCAS New River
BUILDING 1445
NEW RIVER
F ile
P ri n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :2
P
M
G-001
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
TITLE SHEET AND INDEX OF DRAWINGS
60041989 N40085-24-B-0044
05-24-0044 1 OF 9
23 MAY 2025
ROOF REPAIRS BUILDING 1445
MARINE CORPS BASE CAMP LEJUENE
REGIONAL MAP
VICINITY MAP
DISTRICT MAP
PROJECT LOCATION
BUILDING LOCATION GENERAL PROJECT NOTES GOVERNING REGULATIONS
BUILDING CODE:
UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 (01 SEP 2022, W/ CHANGE 3, 26 FEB 2024) UNIFIED FACILITIES CRITERIA (UFC) 1-200-02 (01 DEC. 2020, W/CHANGE 02, 01 JUN 2022) UNIFIED FACILITIES CRITERIA (UFC) 3-110-03 (01 MAY 2012, W/CHANGE 5, 12 JUN 2020)
ACCESSIBILITY CODE:
UNIFORM ACCESSIBILITY STANDARDS (UFAS)
AMERICANS WITH DISABILITIES ACT (ADA)
ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAAG)
MECHANICAL CODE:
INTERNATIONAL MECHANICAL CODE (IMC) 2021
ELECTRICAL CODE:
NFPA 70, NATIONAL ELECTRIC CODE (2023)
PLUMBING CODE:
INTERNATIONAL PLUMBING CODE (IPC) 2021
FIRE PREVENTION & LIFE SAFETY CODE:
UNIFIED FACILITIES CRITERIA (UFC) 3-600-01 (15 DEC. 2016, W/CHANGE 6, 06 MAY 2021)
NFPA 101, LIFE SAFETY CODE (2024)
1. WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION ACTIVITIES, PATCH
AND REPAIR DAMAGED ITEMS USING MATERIALS MATCHING EXISTING CONSTRUCTION.
REPAIRS ARE TO MATCH EXISTING MATERIAL, TEXTURE, AND COLOR TO PROVIDE
SEAMLESS TRANSITION IN APPEARANCE.
2. FIELD VERIFY EXISTING DIMENSIONS AND CONDITIONS, PRIOR TO PREPARING
SUBMITTALS, ORDERING MATERIALS AND BEGINNING WORK.
3. ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND INSTALLED UNDER THE
REQUIREMENTS OF THIS CONTRACT.
4. COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO THE
PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE ESTABLISHED BY
THE CONTRACTING OFFICER.
5. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY.
PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH
THE COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND
MEET THE TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS.
6. OBSERVE AND MAINTAIN BUILDING AND COMPOUND SECURITY REQUIREMENTS AS
DIRECTED BY THE CONTRACTING OFFICER.
7. CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH WILL REMAIN
OPERATIONAL. AVOID INTERFERENCE WITH THE OPERATIONAL WORK ROUTINE.
8. SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS MUST BE SUBMITTED
TO THE CONTRACTING OFFICER FOR APPROVAL PRIOR TO COMMENCEMENT OF
RELATED WORK.
ARCHITECT
MBF ARCHITECTS, P.A.
317-C POLLOCK STREET
NEW BERN, NC 28560
NO CONSULTANTS ARE ENGAGED FOR
THIS ROOF REPLACEMENT PROJECT.
DESIGN TEAM
N
N
N
N
PROJECT NO. 24-0044
BUILDING 1445
LOUIS ROAD
DOGWOOD STREET
PRIOR TO MOBILIZATION
1. PRECONSTRUCTION CONFERENCE
2. APPROVAL OF PRECONSTRUCTION SUBMITTALS
3. APPROVAL OF MATERIAL SUBMITTALS
4. APPROVAL OF CONSTRUCTION SEQUENCE PLAN
MOBILIZE
1. INSTALL TEMPORARY FACILITIES
2. DELIVER MATERIALS
3. CONFIRM NEW EQUIPMENT CURBS ARE CORRECT
4. CONTRACTING OFFICER WILL VERIFY ALL MATERIALS ARE ONSITE PRIOR
TO AUTHORIZING THE START OF WORK
5. WATER TEST EACH ROOF DRAIN AND CONFIRM PROPER FUNCTION PRIOR
TO START OF WORK. REPORT FINDINGS TO CONSTRUCTION MANAGER.
CORRECT PLUGGED DRAINS PRIOR TO THE START
IMPLEMENTATION OF WORK
1. BEGIN WORK AT THE WEST END OF THE LOW ROOF AREA - 'START HERE'
2. DEMOLISH ONLY THE AN AMOUNT OF ROOFING EACH DAY THAT CAN BE
DRIED-IN BY THE END OF THAT DAY. DRIED-IN IS CONSIDERED TO BE ROOF
DECK AIR AND MOISTURE BARRIER INSTALLED AND SEALED AT
PERIMETERS AT A MINIMUM
3. CAREFULLY PLAN WORK AT ROOFTOP EQUIPMENT TO SEQUENCE CRANE
PICKS, NEW CURB INSTALLATION AND RE-INSTALLATION OF ROOFTOP
EQUIPMENT TO MINIMIZE EQUIPMENT DOWN TIME. EQUIPMENT OPERATION
MUST BE RESTORED AND VERIFIED PRIOR TO MOVING TO THE NEXT
SECTION OF ROOFING
4. EQUIPMENT WORK SEQUENCE
A. DISCONNECT DUCTS, PIPING, ELECTRICAL, CONTROLS, ETC.
B. LIFT EQUIPMENT FROM ROOF WITH CRANE
C. REMOVE EXISTING CURB
D. SET NEW CURB
E. REINSTALL EQUIPMENT
F. RECONNECT DUCTS, PIPING, ELECTRICAL, CONTROLS, ETC.
G. START EQUIPMENT AND TEST FUNCTIONALITY
H. DOWNTIME FOR EACH PIECE OF ROOFTOP EQUIPMENT MUST NOT
EXCEED 24 HOURS
5. DO NOT MOVE TO THE NEXT SECTION OF ROOFING WITHOUT APPROVAL
FROM THE CONTRACTING OFFICER
6. ROOF DECK AIR AND MOISTURE BARRIER CANNOT BE EXPOSED BEYOND
MANUFACTURER LIMITATIONS. SEQUENCE INSULATION AND ROOFING
SYSTEM INSTALLATION TO CLOSELY FOLLOW COMPLETION OF DRIED-IN
ROOF AREAS
INSPECTION
1. WATER TEST EACH ROOF DRAIN AND CONFIRM PROPER FUNCTION
FOLLOWING THE COMPLETION OF WORK. REPORT FINDINGS TO
CONSTRUCTION MANAGER. CORRECT ANY PLUGGED DRAINS
2. COORDINATE INSPECTION SCHEDULES WITH THE CONTRACTING OFFICER
TO AVOID DELAYS
1. THE CONSTRUCTION SEQUENCE ITEMS IDENTIFIED HERE ARE NOT
INTENDED TO BE AN INCLUSIVE OF ALL WORK REQUIRED
2. COORDINATION OF CONSTRUCTION SEQUENCING AND DAILY ACTIVITIES IS
SOLELY THE RESPONSIBILITY OF THE CONTRACTOR (KTR)
3. PROTECT BUILDING INTERIORS FROM DEBRIS AND INCLEMENT WEATHER
4. THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION AND THE
ENTIRE BUILDING MUST REMAIN CONTINUOUSLY OPERATIONAL
5. SEQUENCE WORK TO LIMIT DOWNTIME OF ROOFTOP EQUIPMENT TO A
MAXIMUM OF 24 HOURS
PHASE 1 ROOF AREA
PHASE 2 ROOF AREA
WORK FLOW DIRECTION
START
HERE
V
V
V V
V
V
V
V
V
V
V V
VV
V
V
V
V
V
RC-A
RC-A
RC-A
RC-A
RC-C RC-C
RC-A
RC-A RC-A
RC-A RC-A
RC-A
RC-C RC-C
RC-B
RC-A
RC-A
RC-E
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-D
RC-A
PV-C
PV-B
PV-C
PV-D
PV-D PV-D
PV-D
PV-C PV-C
PV-D
PV-D
PV-D
PV-D
PV-C
PV-D
PV-C
PV-F
PV-E
PV-D
PV-C
PV-A
PV-A PV-A PV-A PV-A
PV-E
PV-F
EP
EPEP
EP
CRU-1
RIDGERIDGE
E J
E J
RH
RD
SC
RD RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
TYP
PV-C
GN
SC
GN GN GN GN
GNGN
HS
PV-C
PV-G
V
DH
PV-D
HSANT
V n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :2
P
M
GI101
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
CONSTRUCTION SEQUENCE
60041990 N40085-24-B-0044
05-24-0044 2 OF 9
23 MAY 2025
N
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 8' 16' 24'
CONSTRUCTION SEQUENCE CONSTRUCTION SEQUENCE NOTES CONSTRUCTION SEQUENCE LEGEND
SCALE: 3/32" = 1'-0"
D3
ROOF PLAN - CONSTRUCTION SEQUENCE
N
DRAWING TAG
NORTH ARROW
EXTERIOR ELEVATION TAG
INTERIOR ELEVATION TAG
SECTION TAG
BUILDING SECTION TAG
DETAIL TAG
COLUMN GRID
DEMOLITION KEYNOTE TAG
CONSTRUCTION KEYNOTE TAG
ELEVATION BENCHMARK
WALL TYPE TAG
WINDOW TAG
DOOR TAG
ROOM NAME TAG
DIMENSIONS
XX
DETAIL/SECTION/ELEVATION TITLE
SCALE: X" = 1'-0"
A
Room Name
A-101
XX
XX
XXXX
101A
0 '- 0"
ELEV
LOCATION COORDINATE
DETAIL TITLE
SCALE
PROJECT NORTH
TRUE NORTH
LOCATION COORDINATE
SHEET IDENTIFICATIONA-101
SHEET IDENTIFICATION
LOCATION COORDINATE
TYPICAL
LOCATION COORDINATE
SHEET IDENTIFICATIONA-101
A-101
A-101
LOCATION COORDINATE
TYPICAL
SHEET IDENTIFICATION
TYPICAL
LOCATION COORDINATE
SHEET IDENTIFICATION
COLUMN GRID NUMBER IDENTIFICATION
COLUMN GRID LETTER IDENTIFICATION
X
KEYNOTE NUMBER
KEYNOTE NUMBER
ELEVATION DIMENSION
ELEVATION DESCRIPTION
WALL TYPE IDENTIFIER
WINDOW TYPE IDENTIFIER
DOOR NUMBER
ROOM NAME
ROOM NUMBER
DIMENSIONED (WALL, FRAME, ETC.)
FACE OF ELEMENT BEING
DIMENSIONED (WALL, FRAME, ETC.)
CENTERLINE OF ELEMENT BEING
A-101
SYMBOL LEGEND
ACAIR CONDITIONING
AB ANCHOR BOLT
ADA AMERICANS WITH DISABILITIES ACT
ABA ARCHITECTURAL BARRIERS ACT
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
ALUM ALUMINUM
ALT ALTERNATE
ATC ACOUSTICAL TILE CEILING
AUX AUXILIARY
BD BOARD
BLDG BUILDING
BL BUILDING LINE
BRG BEARING
CFM CUBIC FEET PER MINUTE
CI CURB INLET / CAST IRON
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CM CENTIMETER
COL COLUMN
CONC CONCRETE
CPT CARPET
CY CUBIC YARD
DF DRINKING FOUNTAIN
DH PIPING DOGHOUSE
DIA DIAMETER
DIAG DIAGONAL
DL DEAD LOAD
DN DOWN
DS DOWNSPOUT
DWG DRAWING
EA EACH / EXHAUST AIR
EJ EXPANSION JOINT
EJ/CJ EXPANSION JOINT & CONTROL JOINT
ELEV ELEVATION, ELEVATOR
ELEC ELECTRIC(AL)
EQ EQUAL
EQUP EQUIPMENT
ERD EMERGENCY OVERFLOW ROOF DRAIN
EP EQUIPMENT POST
EW EACH WAY
EX EXHAUST
EXTG EXISTING
EXT EXTERIOR
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
FCU FAN COIL UNIT
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
FIN FINISH
FIXT FIXTURE
FLR FLOOR
FHB FREEZE-PROOF HOSE BIBB
FT FEET
GA GAGE
GALV GALVANIZED
GPM GALLONS PER MINUTE
GWB GYPSUM WALLBOARD
GYP GYPSUM
HB HOSE BIBB
HM HOLLOW METAL
HS HOT STACK
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
JT JOINT
LAV LAVATORY
LF LINEAR FEET
LL LIVE LOAD
LVT LUXURY VINYL TILE
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MO MASONRY OPENING
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OPG OPENING
PWD PLYWOOD
PP PITCH POCKET
PR PAIR
PS PIPE STAND
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PV ROOFTOP POWER EXHAUST FAN
QT QUARRY TILE
RB RESILIENT BASE
RC ROOFTOP EXHAUST/INTAKE CAP
RD ROOF DRAIN
REQ REQUIRED
REV REVERSE READ
READ
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
SC SCUPPER
SD SMOKE DETECTOR
SECT BUILDING SECTION
SHT SHEET
SIM SIMILAR
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TLT TOILET
TOS TOP OF STEEL
TYP TYPICAL
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V VENT THROUGH ROOF
VAV VARIABLE AIR VOLUME
VCT VINYL COMPOSITION TILE
W/ WITH
WD WOOD
WH WATER HEATER
ABBREVIATIONS
n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :2
P
M
A-001
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
SYMBOL LEGEND AND ABBREVIATIONS
60041991 N40085-24-B-0044
05-24-0044 3 OF 9
23 MAY 2025
V
V
V V
V
V
V
V
V
V
V V
VV
V
V
V
V
V
RC-A
RC-A
RC-A
RC-A
RC-C RC-C
RC-A
RC-A RC-A
RC-A RC-A
RC-A
RC-C RC-C
RC-B
RC-A
RC-A
RC-E
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-D
RC-A
.6
:1
.6
:1
.6
:1
.8
:1
.8
:1
.8
:1
.8
:1
PV-C
PV-B
PV-C
PV-D
PV-D PV-D
PV-D
PV-C PV-C
PV-D
PV-D
PV-D
PV-D
PV-C
PV-D
PV-C
PV-F
PV-E
PV-D
PV-C
PV-A
PV-A PV-A PV-A PV-A
PV-E
PV-F
EP
EPEP
EP
CRU-1
RIDGERIDGE
E J
E J
RH
RD
SC
RD RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
RD
SC
±23'-4" ±94'-0" ±253'-10"
±371'-2"
±5 3'
-2
±6 6'
-1 0"
0' -0
1 1
2 2 2
2 2 2 2 2
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
PV-C
GN
SC
GN GN GN GN
GNGN
HS
PV-C
PV-G
V
DH
PV-D
HSANT8 9
7 7
P H
O T
O
E1
AD901
P H
O T O
E2
AD901
P H O
TO
E3
AD901
P H O
TO
D4
AD901
PHO
TO
D4
AD901
PH
O
TO
D6
AD901
P H
O T O
D1
AD901
V
PHOTO
D2
AD901
P H
O T
O
D3
AD901
P H
O
TO
B1
AD901
PHOTO
B3
AD901
PHOTO
B4
AD901
PHOTO
C5
AD901
PHOTO
C5
AD901
PHOTO
A2
AD901
PHOTO
A3
AD901
P H
O T O
A1
AD901
PHOTO
B5
AD901
PHOTO
B6
AD901
1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND AND
ABBREVIATIONS LEGEND
2. DIMENSIONS ARE SHOWN FOR GENERAL INFORMATION AND
THE CONVENIENCE OF CONTRACTOR. CONFIRM
DIMENSIONS IN THE FIELD PRIOR TO BEGINNING WORK.
DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF
THE ARCHITECT VIA A REQUEST FOR INFORMATION
3. DEMOLISH ONLY AS MUCH ROOFING AS CAN BE REPLACED
OR DRIED IN EACH DAY
4. ROOFTOP EQUIPMENT AND APPURTENANCES THAT MUST
BE TEMPORARILY REMOVED TO COMPLETE NEW ROOFING
WORK MUST PROTECTED, REINSTALLED AND RESTORED TO
FULL FUNCTIONALITY WITHIN 24 HOURS OR REMOVAL
5. REFERENCE THE HAZARDOUS MATERIALS ASSESSMENT
REPORT FOR LOCATIONS AND TYPES OF ASBESTOS
CONTAINING MATERIALS (ACM) AND LEAD
6. MANAGE CONSTRUCTION WASTE, MATERIAL RECYCLING,
AND DISPOSAL OF DEMOLITION DEBRIS/WASTE IN
ACCORDANCE WITH THE APPROVED CONSTRUCTION
WASTE MANAGEMENT PROGRAM FOR THE PROJECT
REMOVE MODIFIED BITUMEN ROOFING SYSTEM ASSEMBLY INCLUDING BUT NOT
LIMITED INSULATION, CRICKETS, CANT STRIPS, BASE FLASHINGS, ETC. DOWN TO
STEEL ROOF DECK
REMOVE SHEET METAL COPING
REMOVE ROOF HATCH. MAINTAIN EXISTING HATCH FOR WEATHER TIGHTNESS
UNTIL READY FOR REPLACEMENT
REMOVE LADDER TO FACILITATE ROOFING WORK. PROTECT LADDER FOR
REINSTALLATION
PROTECT ROOFTOP EQUIPMENT. EQUIPMENT MUST REMAIN OPERATIONAL UNTIL
REMOVED DISCONNECTION/RECONNECTION WORK RELATED TO NEW ROOFING
WORK
REMOVE ROOF EXPANSION JOINT FLASHING. MAINTAIN BUILDING WEATHER
TIGHTNESS. SEE DETAILS AND
REMOVE RETROFIT ROOF DRAIN AND PARENT ROOF DRAIN
WALL MOUNTED ANTENNA. DO NOT DISTURB
BOILER STACKS. DO NOT DISTURB
/A1 A-501 /C1 A-501
ROOFTOP APPURTENANCES AND EQUIPMENT TO REMAIN
ROOFTOP APPURTENANCES AND EQUIPMENT TO BE
REMOVED
RD
ROOF DRAIN AND INSULATION SUMP
EMERGENCY OVERFLOW SCUPPER
ROOF ACCESS LADDER
ROOF ACCESS HATCH
SLOPE DIRECTION
ROOF SYSTEM WALKPAD
ROOFTOP POWER EXHAUST FAN
ROOFTOP EXHAUST/INTAKE CAP
PIPING DOGHOUSE
HOT STACK
PLUMBING VENT THROUGH ROOF (VTR)
GOOSENECK EXHAUST/INTAKE CAP
EQUIPMENT STAND POST
WP
SC
RH
V
RC
PV
DH
GN
HS
EP
n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :3
P
M
AD101
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
ROOF PLAN - EXISTING/DEMOLITION
60041992 N40085-24-B-0044
05-24-0044 4 OF 9
23 MAY 2025
N
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 8' 16' 24'
SCALE: 3/32" = 1'-0"
D3
ROOF PLAN - EXISTING/DEMOLITION
GENERAL DEMOLITION NOTES DEMOLITION KEYNOTES
DEMOLITION LEGEND
ROOF PLAN LEGEND
n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :4
P
M
AD901
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
PHOTOGRAPHIC DOCUMENTATION
60041993 N40085-24-B-0044
05-24-0044 5 OF 9
23 MAY 2025
SCALE: 12" = 1'-0"
E1
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
E2
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
E3
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
C5
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
D4
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
D1
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B4
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
D2
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
D6
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
D3
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B1
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B2
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B3
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
A1
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
A4
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
A2
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
A3
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B5
PHOTOGRAPHIC DOCUMENTATION
SCALE: 12" = 1'-0"
B6
PHOTOGRAPHIC DOCUMENTATION
.6
:1
.6
:1
.6
:1
.8
:1
.8
:1
.8
:1
.8
:1
11 1 1 1
11111
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP 3
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
WP
WPWP
WP
V
V
V V
V
V
V
V
V
V
V V
VV
V
V
V
V
V
RC-A
RC-A
RC-A
RC-A
RC-C RC-C
RC-A
RC-A RC-A
RC-A RC-A
RC-A
RC-C RC-C
RC-B
RC-A
RC-A
RC-E
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-A
RC-D
RC-A
PV-C
PV-B
PV-C
PV-D
PV-D PV-D
PV-D
PV-C PV-C
PV-D
PV-D
PV-D
PV-D
PV-C
PV-D
PV-C
PV-F
PV-E
PV-D
PV-C
PV-A
PV-A PV-A PV-A PV-A
PV-E
PV-F
EP
EPEP
EP
CRU-1
RIDGERIDGE
E J
E J
RH
SC SC SC SC SC SC SC SC SC SC
RD
SC SC SC SC SC SC SC SC SC SC SC SC SC
PV-C
GN
SC
GN GN GN GN
GNGN
HS
PV-C
PV-G
V
DH
PV-D
HSANT
TYP
18 19
RD RD RD RD RD RD RD RD RD RD RD RD
RDRDRDRDRDRDRDRDRDRDRD
TYP
13 13
V
TYP
TYP
E5
A-501
E5
A-501
E5
A-501
E5
A-501
E5
A-501
E5
A-501
E5
A-501
C5
A-501
C5
A-501 C5
A-501
C5
A-501
C5
A-501
C5
A-501
B5
A-501
E1
A-501
E1
A-501
C1
A-501
A1
A-501
A1
A-501
1. REFERENCE SHEET A-001 FOR SYMBOL LEGEND
2. REFERENCE SERIES A-5XX SHEETS FOR ROOFING DETAILS
3. PROTECT MATERIALS AND SYSTEMS THAT ARE SCHEDULED TO
REMAIN
4. MANAGE CONSTRUCTION WASTE, MATERIAL RECYCLING, AND
DISPOSAL OF DEMOLITION DEBRIS/WASTE IN ACCORDANCE WITH
THE APPROVED CONSTRUCTION WASTE MANAGEMENT PROGRAM
FOR THE PROJECT
PROVIDE ROOF DECK AIR AND MOISTURE BARRIER,
MECHANICALLY FASTENED RIGID ROOF INSULATION AND
MODIFIED BITUMEN ROOFING SYSTEM. SEE DETAIL
RIGID INSULATION CRICKET. PROVIDE 1/2" FINISHED SLOPE.
SYSTEM COVER BOARD MUST BE CONTINUOUS OVER CRICKETS
TEMPORARILY DISCONNECT AND LIFT ROOFTOP MECHANICAL
EQUIPMENT FOR ROOFING SYSTEM INSTALLATION. EXTEND
CURBS TO MAINTAIN CLEARANCE ABOVE ROOFING SURFACE.
RECONNECT UNITS AND CONFIRM PROPER FUNCTION. SEE
DETAIL . PROVIDE INSULATION CRICKET AT UPSLOPE
SIDE TO DIRECT WATER AROUND CURB
PROVIDE NEW MODIFIED BITUMEN ROOFING SYSTEM WALKPADS
AT SELECT ROOFTOP MECHANICAL EQUIPMENT, ROOF HATCH
AND ROOF LADDERS
PROVIDE ROOF HATCH AND SAFETY RAILS. MATCH OPENING
DIMENSIONS OF EXISTING HATCH. SEE DETAIL .
PREPARE, PRIME AND PAINT EXISTING LADDER SAFETY YELLOW
PREPARE, PRIME AND PAINT LADDER PRIOR TO REINSTALLATION.
MATCH EXISTING COLOR. PROVIDE STAINLESS STEEL EXPANSION
BOLTS
PROVIDE SHEET METAL COPING AND UNDERLAYMENT. PROVIDE
CONCEALED SPLICE PLATES. SEE DETAIL
ROOF DRAIN. SEE DETAIL
EMERGENCY OVERFLOW SCUPPERS. SEE DETAIL
BUILDING EXPANSION JOINT. SEE DETAIL
/E1 A-502
/E4 A-502
/D6 A-502
/E1 A-503
/A3 A-502
/B3 A-503
/A1 A-501
PLUMBING VENT THROUGH ROOF. SEE DETAIL
BASE FLASHING. SEE DETAIL
ENGAGE PROPERLY LICENSED PLUMBING CONTRACTOR TO
REPLACE THE EXISTING ROOF DRAIN WITH NEW 4" DRAIN
ASSEMBLY. SEE DETAIL . PROVIDE ROOF DRAIN
ACCESSORIES FOR A COMPLETE INSTALLATION INCLUDING BUT
NOT LIMITED TO ROOF DECK CLAMPS, CAST IRON DRAIN BODY,
PIPE CONNECTION ADAPTER, CAST ALUMINUM STRAINER, ETC.
INSULATE DRAIN BODY AND ELBOW
PREPARE, PRIME AND PAINT ENTIRE EQUIPMENT STAND
INCLUDING POSTS PRIOR TO REINSTALLATION OF CONDENSING
UNIT
PIPING DOGHOUSE. SEE DETAIL
±4" DIA EQUIPMENT STAND POST. SEE DETAIL .
HOT STACK. SEE DETAIL
ANTENNA. DO NOT DAMAGE OR DISTURB
BOILER STACKS. DO NOT DAMAGE OR DISTURB
BUILDING EXPANSION JOINT AT BASE FLASHING.
SEE DETAIL
/A3 A-502
/A1 A-502
/E1 A-501
15 /B6 A-502
/C3 A-502
/C1 A-502
/C1 A-501
RD
ROOF DRAIN AND INSULATION SUMP
EMERGENCY OVERFLOW SCUPPER
ROOF ACCESS LADDER
ROOF ACCESS HATCH
SLOPE DIRECTION
ROOF SYSTEM WALKPAD
ROOFTOP POWER EXHAUST FAN
ROOFTOP EXHAUST/INTAKE CAP
PIPING DOGHOUSE
HOT STACK
PLUMBING VENT THROUGH ROOF (VTR)
GOOSENECK EXHAUST/INTAKE CAP
EQUIPMENT STAND POST
WP
SC
RH
V
RC
PV
DH
GN
HS
EP
n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :4
P
M
A-101
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
ROOF PLAN - CONSTRUCTION
60041994 N40085-24-B-0044
05-24-0044 6 OF 9
23 MAY 2025
SCALE: 3/32" = 1'-0"
D3
ROOF PLAN - CONSTRUCTION
N
GRAPHIC SCALE: 3/32"=1'-0"
8' 0 8' 16' 24'
GENERAL CONSTRUCTION NOTES CONSTRUCTION KEYNOTES ROOF PLAN LEGEND
EXISTING MASONRY
PARAPET TO REMAIN
REMOVE SHEET METAL
COPING INCLUDING CLEATS
AND SPLICE PLATES
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
EXISTING WOOD NAILER
TO REMAIN
3/4" CDX PLYWOOD PREFINISHED SHEET METAL
ALUMINUM COPING WITH
CONCEALED SPLICE PLATES.
MATCH EXISTING COLOR
WRAP TOP OF PARAPET
WITH PEEL & STICK
UNDERLAYMENT
ROOFING SYSTEM BASE
FLASHING - EXTEND TO TOP OF
PARAPET
CONTINUOUS
FIBERBOARD CANT
CONTINUOUS TREATED WOOD
CANT. 1 1/2" TO 0"
SLOPE
ROOF DECK AIR AND MOISTURE
BARRIER. CONTINUE OVER
PARAPET
9"±
4"
1/
2"
± 1'-0"
REMOVE FIBERBOARD
CANT
EXISTING SLOPED
STEEL ROOF DECK AND
FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
9"4"
ALIGN BOTTOM EDGE OF
COPING WITH LINE OF
EXISTINGMODIFIED BITUMEN
ROOFING SYSTEM
RIGID INSULATION
CRICKET. 0.5:12
FINISHED SLOPE
2'
-2
EXISTING MASONRY
PARAPET TO REMAIN
REMOVE SHEET METAL
COPING INCLUDING CLEATS
AND SPLICE PLATES
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
EXISTING WOOD NAILER
TO REMAIN
3/4" CDX PLYWOOD
PREFINISHED SHEET METAL
ALUMINUM COPING WITH
CONCEALED SPLICE PLATES.
MATCH EXISTING COLOR
WRAP TOP OF PARAPET
WITH PEEL & STICK
UNDERLAYMENT
ROOFING SYSTEM BASE
FLASHING - EXTEND TO
TOP OF PARAPET
CONTINUOUS
FIBERBOARD CANT
CONTINUOUS TREATED WOOD
CANT. 1 1/2" TO 0"
SLOPE
ROOF DECK AIR AND MOISTURE
BARRIER. CONTINUE OVER
PARAPET
9"±
4"
1/
2" REMOVE FIBERBOARD
CANT
EXISTING SLOPED
STEEL ROOF DECK AND
FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
9"4"
ALIGN BOTTOM EDGE OF
COPING WITH LINE OF
EXISTING
MODIFIED BITUMEN
ROOFING SYSTEM
V A
R
IE
S
" M
IN
EXISTING MASONRY
PARAPET TO REMAIN
REMOVE SHEET METAL
COPING INCLUDING CLEATS
AND SPLICE PLATES
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
EXISTING WOOD NAILER
TO REMAIN
3/4" CDX PLYWOOD
WRAP TOP OF PARAPET
WITH PEEL & STICK
UNDERLAYMENT
ROOFING SYSTEM BASE
FLASHING - EXTEND TO TOP OF
PARAPET
CONTINUOUS
FIBERBOARD CANT
ROOF DECK AIR AND MOISTURE
BARRIER. CONTINUE OVER
PARAPET
9"±
4"
1/
2"
± 1'-0"
REMOVE FIBERBOARD
CANT
EXISTING SLOPED
STEEL ROOF DECK AND
FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
MODIFIED BITUMEN
ROOFING SYSTEM
±1 '-2
PREFINISHED SHEET METAL
ALUMINUM COPING WITH
CONCEALED SPLICE PLATES.
MATCH EXISTING COLOR
CONTINUOUS TREATED WOOD
CANT. 1 1/2" TO 0"
SLOPE
9"4"
ALIGN BOTTOM EDGE OF
COPING WITH LINE OF
EXISTING
EXISTING MASONRY
PARAPET TO REMAIN
REMOVE SHEET METAL
COPING INCLUDING CLEATS
AND CONCEALED SPLICE
PLATES
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
3/4" CDX PLYWOOD
ROOFING SYSTEM BASE
FLASHING - EXTEND TO TOP OF
PARAPET
CONTINUOUS
FIBERBOARD CANT
ROOF DECK AIR AND MOISTURE
BARRIER. EXTEND OVER
PLYWOOD, UP ONTO WALL AND
SEAL
EXISTING SLOPED
STEEL ROOF DECK AND
FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
MODIFIED BITUMEN
ROOFING SYSTEM
A-503 E5
V A
R
IE
S
WRAP AIR AND MOISTURE
BARRIER MEMBRANE UP ONTO
BRICK AND SEAL
EXISTING MASONRY
PARAPET TO REMAIN
REMOVE MODIFIED BITUMEN
FLASHING
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
3/4" CDX PLYWOOD
ROOFING SYSTEM WALL
FLASHING. LAP ONTO
FLASHING
CONTINUOUS
FIBERBOARD CANT
ROOF DECK AIR AND MOISTURE
BARRIER. EXTEND OVER
WOOD NAILERS, UP ONTO
WALL AND SEAL. ALLOW FOR
EXPANSION/CONTRACTION
EXISTING SLOPED
STEEL ROOF DECK AND
FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
MODIFIED BITUMEN
ROOFING SYSTEM
A-503 E5
± 1"
REUSE EXISTING
REGLET AND FLASHING
RECEIVER
SHEET METAL
COUNTERFLASHING
REMOVE SHEET METAL
COUNTERFLASHING
REMOVE WOOD
NAILERS
REMOVE SHEET METAL
EXPANSION JOINT FLASHING ±4"SHEET METAL EXPANSION JOINT
FLASHING. SECURE TO WALL
WITH EXPANSION ANCHORS
2 6 2 6
CONTINUOUS TREATED NAILER.
ANCHOR TO DECK ANGLE WITH
1/4" DIA GALVANIZED BOLTS
CONTINUOUS TREATED
NAILERS. ANCHOR TO ROOF
DECK WITH NO. 12 TEK
SCREWS. STAGGER JOINTS
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
EXISTING SLOPED STEEL ROOF
DECK AND FRAMING TO REMAIN
EXISTING/DEMOLITION CONSTRUCTION
REMOVE WOOD
NAILERS
REMOVE SHEET METAL
EXPANSION JOINT FLASHING CONTINUOUS TREATED NAILER.
ANCHOR TO DECK ANGLE WITH
1/4" DIA GALVANIZED BOLTS
± 1"
REMOVE MODIFIED BITUMEN
ROOFING SYSTEM ASSEMBLY
INCLUDING BUT NOT LIMITED
INSULATION, CRICKETS, CANT
STRIPS, BASE FLASHINGS, ETC.
DOWN TO STEEL ROOF DECK
EXISTING SLOPED STEEL ROOF
DECK AND FRAMING TO REMAIN
± 1"
CONTINUOUS FIBERBOARD
CANT EACH SIDE
MODIFIED BITUMEN
ROOFING SYSTEM
EACH SIDE
SHEET METAL EXPANSION JOINT
FLASHING. CONTINUOUS
CLEATS EACH SIDE
2 6
CONTINUOUS TREATED
NAILERS. ANCHOR TO ROOF
DECK WITH NO. 12 TEK
SCREWS. STAGGER JOINTS
ROOF DECK AIR AND MOISTURE
BARRIER. EXTEND OVER
WOOD NAILERS. ALLOW FOR
EXPANSION/CONTRACTION
ROOF DECK AIR AND
MOISTURE BARRIER.
CONTINUE OVER WOOD
NAILERS
n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :4
P
M
A-501
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
DETAILS
60041995 N40085-24-B-0044
05-24-0044 7 OF 9
23 MAY 2025
GRAPHIC SCALE: 1 1/2"=1'-0"
1' 6" 3" 0 1'
SCALE: 1 1/2" = 1'-0"
E5
TYPICAL PARAPET DETAIL AT DRAINS
SCALE: 1 1/2" = 1'-0"
C5
TYPICAL PARAPET DETAIL PARALLEL TO SLOPE
SCALE: 1 1/2" = 1'-0"
B5
TYPICAL PARAPET DETAIL AT HIGH BAY TOP OF SLOPE
SCALE: 1 1/2" = 1'-0"
E1
TYPICAL BASE FLASHING DETAIL AT HIGH WALL
SCALE: 1 1/2" = 1'-0"
C1
BUILDING EXPANSION JOINT DETAIL AT HIGH WALL
SCALE: 1 1/2" = 1'-0"
A1
EXPANSION JOINT DETAIL
PREFABRICATED ALUMINUM
PIPING DOGHOUSE
EXIT SEAL, TYPICAL
INSULATED REFRIGERANT
LINE SETS OR CONDUITS
SEAL PIPE PENETRATIONS
IN DECK WITH SELF
ADHERING AIR AND
MOISTURE BARRIER
NOTES:
1. FILL VOID INSIDE CURB WITH MINERAL FIBER INSULATION
A-502
E4SIM
INSULATED CURB
PIPE, CONDUIT, LIGHTNING
PROTECTION CONDUCTOR
PENETRATION, ETC.
STAINLESS STEEL CAP FLASHING.
SECURE TO STACK WITH A HEAVY
DUTY STAINLESS STEEL BAND CLAMP
SET PITCH POCKET PAN
FLASHING IN A FULL BED OF
ROOFING SYSTEM MASTIC
MODIFIED BITUMEN
ROOFING SYSTEM
SEAL DECK OPENING ALL
AROUND TO PREVENT
POURABLE SEALER FROM
ENTERING BUILDING
SEALANT
1/
2"
3"
8" M
IN
FILL PITCH POCKET FULL WITH
ROOFING SYSTEM POURABLE SEALER.
CROWN TOP TO SHED WATER
WRAP WITH ROOF
DECK AIR AND
MOISTURE BARRIER
EQUIPMENT POST
STAINLESS STEEL CAP FLASHING.
SECURE TO PIPE WITH A HEAVY DUTY
STAINLESS STEEL BAND CLAMP
MODIFIED BITUMEN
ROOFING SYSTEM
PIPE FLASHING AND
STRIPPING
MODIFIED BITUMEN
ROOFING SYSTEM
SEALANT
8" M
IN
WRAP WITH ROOF DECK
AIR AND MOISTURE
BARRIER
EXHAUST/INTAKE STACK
STAINLESS STEEL CAP FLASHING.
SECURE TO STACK WITH A HEAVY
DUTY STAINLESS STEEL BAND CLAMP
SET HOT STACK COLLAR FLASHING
IN A FULL BED OF ROOFING
SYSTEM MASTIC
MODIFIED BITUMEN
ROOFING SYSTEM
MINERAL WOOL INSULATION
HIGH TEMPERATURE
SEALANT
CLEAR
1 1/2" MINIMUM
1/
2"
3"
8" M
IN
WRAP WITH ROOF DECK
AIR AND MOISTURE
BARRIER
ROOF HATCH
ASSEMBLY
SECURE ROOFING SYSTEM
FLASHING UNDER HATCH
FLASHING
SECTION
B
RAILINGROOF HATCH
2'-6" x 3'-0"
1' -0
" T Y
P
SWING GATE
WITH SPRING
HINGES AND
SAFETY LATCH
PLAN
A
A
.1
-1
H E
IG
H
T A
S R
E Q
U
IR
E D
B Y
O S
H A
S
TA
N D
A R
D #1
0.
A
N D
A N
S I
ROOF DECK AIR AND
MOISTURE BARRIER
MODIFIED BITUMEN
ROOFING SYSTEM
ROOF STRUCTURE
8" M
IN
3" 6"
1/
2"
LEAD VENT STACK FLASHING
ELASTOMERIC CEMENT
SET FLANGE IN A BED OF
ROOFING CEMENT
MODIFIED BITUMEN
ROOFING SYSTEM
SYSTEM COVER BOARD
POLYISOCYANURATE
INSULATION
NOTES:
1. TWO PLY STRIPPING IS TO BE UTILIZED AT ALL SIMILAR FLASHING CONDITIONS
2. VENT PIPE SIZES VARY. CONFIRM IN THE FIELD
3. METAL SURFACES THAT ARE TO RECEIVE BITUMEN MUST BE COATED WITH ASPHALT PRIMER
4. EXTEND PIPES WITH SCHEDULE 40 CAST IRON PIPE AND NO-HUB CONNECTORS TO ACHIEVE
THE 8" MINIMUM DIMENSION
ROOF DECK AIR AND
MOISTURE BARRIER
8" M
IN
DISCONNECT/RECONNECT
ELECTRICAL TO
COMPLETE CURB
REPLACEMENT
DUCT WALL INSIDE
CURB
FILL VOIDS BETWEEN
THE DUCT AND CURB
WITH BATT
INSULATION
MECHANICAL EQUIPMENT
24 GAUGE STAINLESS STEEL
COUNTER FLASHING
STAINLESS STEEL HEX
WASHER SCREWS WITH
INTEGRAL GASKETS
REPLACE EXISTING CURBS WITH
PREFABRICATED INSULATED
CURBS. MECHANICALLY
FASTEN TO STEEL ROOF DECK
AND FRAMING
ROOF DECK AIR AND
MOISTURE BARRIER
GRANULAR SURFACED
MODIFIED CAP SHEET
MODIFIED BASE SHEET
(1) 1/2" LAYER CEMENT BOARD
SHEATHING COVER BOARD
(1) 1" LAYER AND (2) 2" LAYERS
RIGID POLYISOCYANURATE
INSULATION. STAGGER
INSULATION JOINTS
ROOF DECK AIR
AND MOISTURE
BARRIER
NOTES:
1. COVER BOARD AND INSULATION ASSEMBLY IS MECHANICALLY
FASTENED TO STEEL ROOF DECK
2. ASSEMBLY ACHIEVES A TOTAL R VALUE OF 34.0 (U 0.029)
(1) 1/2" LAYER GYPSUM BOARD
SHEATHING COVER BOARD ON
STEEL ROOF DECK
ROOF DRAIN
ASSEMBLY
A-502
E1 MODIFIED BITUMEN
ROOFING SYSTEM
SOFT METAL PAN
MODIFIED
BITUMEN BASE
SHEET
ROOF DECK AIR
AND MOISTURE
BARRIER
MODIFIED BITUMEN
ROOFING SYSTEM
RIGID INSULATION
EXISTING SLOPED STEEL
ROOF DECK AND
FRAMING TO REMAIN
ROOF DECK AIR AND
MOISTURE BARRIER
COVER BOARD
A-502 E1 n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :4
P
M
A-502
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
DETAILS
60041996 N40085-24-B-0044
05-24-0044 8 OF 9
23 MAY 2025
GRAPHIC SCALE: 3"=1'-0"
0 3" 6" 1"
GRAPHIC SCALE: 1 1/2"=1'-0"
1' 6" 3" 0 1'
GRAPHIC SCALE: 3/4"=1'-0"
1' 0 1' 2' 3'
SCALE: 1 1/2" = 1'-0"
B6
PIPING DOGHOUSE DETAIL
SCALE: 1 1/2" = 1'-0"
C4
PITCH POCKET DETAIL
SCALE: 1 1/2" = 1'-0"
C1
EQUIPMENT POST DETAIL
SCALE: 1 1/2" = 1'-0"
C3
HOT STACK DETAIL
SCALE: 3/4" = 1'-0"
D6
ROOF HATCH DETAIL WITH SWING GATE
SCALE: 3" = 1'-0"
A1
VENT THROUGH ROOF DETAIL
SCALE: 1 1/2" = 1'-0"
E4
MECHANICAL CURB DETAIL
SCALE: 1 1/2" = 1'-0"
E1
MODIFIED BITUMEN ROOFING SYSTEM DETAIL
SCALE: 1 1/2" = 1'-0"
A3
ROOF DRAIN DETAIL
SCALE: 1 1/2" = 1'-0"
E3
TYPICAL ROOFING SYSTEM DETAIL
SILICONE SEALANT,
CONTINUOUS AT
TOP AND SIDES
HEMMED EDGE,
CONTINUOUS AT
FLANGE
SCUPPER FLANGE
COUNTERFLASHING
HEMMED EDGE,
CONTINUOUS AT
FLANGE
3"
EXISTING
±7" 3"
3"
E X
IS
TI
N G
±3
3"
CONTINUOUS FLANGE
WITH A HEMMED EDGE
SECTION
ELEVATION
COUNTERFLASHING
FLASH SCUPPER FLANGE
INTO ROOFING SYSTEM
BASE FLASHING AT THE
INSIDE OF THE PARAPET
REGLET AND
SEALANT
BRICK
EMERGENCY
OVERFLOW
SCUPPER
NOTES:
1. INSTALL INTEGRAL CLOSURE AT EXPOSED ENDS
2. FIELD VERIFY A BREAK PROFILE THAT IS SUITABLE FOR
SPECIFIC DETAIL CONDITIONS PRIOR TO FABRICATION
3. PROVIDE 4" SPLICE JOINTS
4. DIM A = 4"
EXISTING REGLET
MASONRY WALL
MORTAR JOINT
HEMMED DRIP
D
IM
A V
A R
IE
S
REMOVE AND
REPLACE SEALANT
REUSE EXISTING
REGLET AND FLASHING
RECEIVER
SHEET METAL
COUNTERFLASHING
SHEET METAL
COUNTERFLASHING
SEALANT
PARAPET WALL
CONTINUOUS CLEAT
SHEET METAL
PARAPET COPING
TURN PARAPET COPING
FLANGE UP WALL BEHIND
COUNTERFLASHING AND SET IN
A FULL BED OF MASTIC
ABUTTING WALL
3"
E X
IS
TI
N G
A-503 E6
A-503 E5
D
IM
A
1/2"
REFERENCE SECTIONS FOR
NOMINAL COPING WIDTH
PITCH COPING TO DRAIN
TOWARD THE ROOF
1/4" JOINT TO ACCOMMODATE EXPANSION
AND CONTRACTION
DIM A = ±9" FRONT, MATCH EXISTING
±4" BACK
6" WIDE CONCEALED SPLICE
PLATE WITH (3) CONTINUOUS
BEADS OF SILICONE SEALANT AT
BOTH SIDES OF THE JOINT
CONTINUOUS PREFABRICATED
TRACK OR TREATED NAILERS TO
PITCH FOR DRAINAGE
CONTINUOUS CLEAT SECURED TO
BLOCKING, PROVIDE AT ALL
VERTICAL FACES
3/4" CDX PLYWOOD
TERMINATION BAR
MODIFIED BITUMEN
ROOFING SYSTEM
8" M
IN
E X
IS
TI
N G
REUSE EXISTING
REGLET AND
FLASHING RECEIVER
CONTINUOUS SHEET METAL
COUNTERFLASHING. 4" SPLICES
4"
A-503 E6
3/8"
D E
P
TH
3/ 8"
TOOL A CONCAVE
JOINT PROFILE
SILICONE
SEALANT
BACKER ROD
3/8"
TOOL A CONCAVE
JOINT PROFILE
SILICONE
SEALANT
BACKER ROD
D E
P
TH
3/ 8"
CORNER
A
WALL
B n t
SYM. DESCRIPTION DATE APP.
REVISIONS
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERETSI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
DR.
DES.
CHK.
SUBMITTED BY:
DESIGN DIR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
DATE
DATE
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
CAMP LEJEUNE, NORTH CAROLINA
MARINE CORPS BASE
SIZE CODE IDENT. NO. NAVFAC DRAWING NO.
E1 80091
CONSTR. CONTR. NO.
AS NOTEDSCALE SHEET
M B
F A
N O
SPEC.
S p ro je c ts
\2
\2
C
L R o o f R e p a ir s B ld g
\2
D e s ig n \2
D w g
\2
A
R C
H
.r v t
/3
/2
:0 :4
P
M
A-503
REL
DJE,III
REL
ROOF REPAIRS
BUILDING 1445
DETAILS
60041997 N40085-24-B-0044
05-24-0044 9 OF 9
23 MAY 2025
GRAPHIC SCALE: 1"=1"
0 1" 2"
GRAPHIC SCALE: 3"=1'-0"
0 3" 6" 1"
GRAPHIC SCALE: 1 1/2"=1'-0"
1' 6" 3" 0 1'
SCALE: 3" = 1'-0"
B3
SCUPPER DETAIL
SCALE: 3" = 1'-0"
E6
COUNTERFLASHING DETAIL
SCALE: 1 1/2" = 1'-0"
E3
PARAPET COPING TERMINATION DETAIL
SCALE: 3" = 1'-0"
E1
COPING DETAIL
SCALE: 1 1/2" = 1'-0"
E5
BASE FLASHING DETAIL
SCALE: 1" = 1"
B4
SEALANT POCKET DETAILS
| GENERAL |
| G-001 - TITLE SHEET AND INDEX OF DRAWINGS |
| GI101 - CONSTRUCTION SEQUENCE |
| ARCHITECTURAL |
| A-001 - SYMBOL LEGEND AND ABBREVIATIONS |
| AD101 - ROOF PLAN - EXISTING/DEMOLITION |
| AD901 - PHOTOGRAPHIC DOCUMENTATION |
| A-101 - ROOF PLAN - CONSTRUCTION |
| A-501 - DETAILS |
| A-502 - DETAILS |
| A-503 - DETAILS |
File details come from the government source that posted it. Updated .