AMND 0005 200071.pdf
PDF 527 KB Posted
- Attached to
- Construct AARF Fire Trainer Pad, SAS3455
- Solicitation number
- N4008521R0119
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0007 200071.pdf | ||
| Amend 0006 200071.pdf | ||
| 60033564_REV 001_Flat.pdf | ||
| 60033565_REV 001_Flat.pdf | ||
| 26 42 14.00 10.pdf | ||
| S-401 REV 001.pdf | ||
| 60033567_REV 001_Flat.pdf | ||
| S-501 REV 001.pdf | ||
| AMND 0004.pdf | ||
| S-101 REV 001.pdf | ||
| Amend 0003 200071.pdf | ||
| 26 42 14.00 10.pdf | ||
| Amend 0001 200071.pdf | ||
| N4008520B0071 Specs.pdf | ||
| N4008520B0071 Dwgs.pdf | ||
| RFP 200071.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicble)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 11)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a)By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPIRATION DATA (If required)
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
N40085-21-R-0119 Amendment 0005
CONTINUATION SHEET
1. QUESTION: Can the number of days to perform the work be changed to 180 days?
ANSWER: No. The following revised schedule shall be followed for this project:
The new fire trainer system is slated to arrive on 10/1/21. The concrete pad must be poured, cured, and ready for the trainer to be installed by 10/1/21. This also includes any necessary utilities and conduits. All other aspects of the project that are not necessary to be completed by the installation date may be completed afterwards. The Contractor is to confirm with the installation contractor and/or manufacturer what work must be completed for installation.
Overall CCD is 150 days.
2. All other terms and conditions remain unchanged.
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033580
M-501
MECHANICAL DETAILS
PROPANE TANK SCHEMATIC FLOW DIAGRAMA
T. HAHN
J. KULENGUSKI
C. LAMBERT
TYPICAL PIPE TRENCH DETAILDCONDUIT CONNECTION DETAILCPUMP PAD DETAILB
04/30/2021
| Amend 0005 |
| Untitled |
| Untitled |
| 0005 SF30 Continuation Sheet |
| 60033580 |
| Sheets and Views |
| M-501 MECHANICAL DETAILS |
| IDCode: |
| Page: 1 |
| Pages: 3 |
| AmendNo: AMENDMENT NO. 0005 |
| EffDate: 06/03/21 |
| ReqNo: |
| ProjNo: 20-0071 |
| IssCode: N40085 |
| IssuedBy: NAVFAC Mid-Atlantic |
Resident Officer in Charge of Construction 1005 Michael Road Camp Lejeune, NC 28547-2521
| AdmCode: |
| AdminBy: See Item 6 |
| ContName: |
| ContStrt: |
| ContCnty: |
| ContSt: |
| ContZIP: |
| Code: |
| FacCode: |
| SolChgYs: Yes |
| SolChgNo: Off |
| SolAmdNo: N40085-21-R-0119 |
| AmendDate: 5/11/21 |
| ModNo: |
| ModDate: |
| NoCopies: 1 |
| Amended: Yes |
| OffrExt: Yes |
| OffrNoEx: Off |
| ApprData: |
| ChgeOrd: Off |
| ChgeOrder: |
| Modify: Off |
| SuppAgre: Off |
| SuppAuth: |
| ModOthr: Off |
| OthrSpec: |
| NoReq: Off |
| Require: Off |
| Copies: |
| Descript: 20-0071, Construct AARF Fire Trainer Pad, SAS3455 |
Amendment 0005, Answer Requests for Information
The time and date for receipt of proposals remains 1400, 07 June 2021.
This amendment should be acknowledged when your proposal is submitted. Failure to acknowledge the amendment may constitute grounds for rejection of a proposal.
See Continuation Page(s)
| SignName: |
| SignTitl: |
| ContDate: |
| CoName: |
| CoTitle: |
| CODate: |