N4008520B0071 Dwgs.pdf
PDF 15 MB Posted
- Attached to
- Construct AARF Fire Trainer Pad, SAS3455
- Solicitation number
- N4008521R0119
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0007 200071.pdf | ||
| Amend 0006 200071.pdf | ||
| AMND 0005 200071.pdf | ||
| 60033564_REV 001_Flat.pdf | ||
| 60033565_REV 001_Flat.pdf | ||
| 26 42 14.00 10.pdf | ||
| S-401 REV 001.pdf | ||
| 60033567_REV 001_Flat.pdf | ||
| S-501 REV 001.pdf | ||
| AMND 0004.pdf | ||
| S-101 REV 001.pdf | ||
| Amend 0003 200071.pdf | ||
| 26 42 14.00 10.pdf | ||
| Amend 0001 200071.pdf | ||
| N4008520B0071 Specs.pdf | ||
| RFP 200071.pdf |
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033559
COVER SHEET
SHEET DESIG. TITLE
G-001 COVER SHEET
INDEX OF DRAWINGS
SHEET NUMBER
of 29 of 29 of 294 of 29 of 29 of 29 of 29 of 29
CS101 SITE LAYOUT PLAN
60033559
60033563 60033562
60033564 60033565 60033566 60033567 60033568 60033569
NAVFAC NUMBER
CD101 SITE PLAN-EXISTING CONDITIONS AND DEMOLITION
60033560 of 2960033561
RIVER
New Bern
Dover
Tuscarora KinstonGoldsboro US 70
NEUSE
CHERRY POINT
Pollocksville
Trenton Seven Springs
OAK GROVE
US 7
Otway
Beaufort
US
Morehead City
N
E O
C A
MaysvilleComfort
US
Verona
Folkstone
Dixon
Holly Ridge
NEW
RIVER
Pink
Beulaville
Hill
Mt. Olive
Warsaw
Rosehill
US
US 421
Wallace
Jacksonville
Richlands
I
T C
A N
US
Hampstead
T L
Scott Hill
A
Burgaw
Acme Delco
Leland Wilmington
CAMP LEJEUNE
Havelock
Swansboro
4 & Bolton
Words Corner
Magnolia
Swam p
RADIO
TOWER
Bell
ST7
FIRE TOWER
SB72
N.C
RT.
172RNGF3
ROAD
LYMAN
R N
G F4
RN
G
F2
R
NG
F5
BEAR
INLET
Creek
Bear
Saunders Island
RNG N1
BROWNS INLET
OUTPOST
R O
AD
STARLING
CREEK
FERRY
R O
AD
ST21
Free man
DUCK
Cr.
E C
O
A N
BEACH
AREA
OCEAN DR.
W
ATERWAY
Cr.
BEACH
G illets
C r.
RD.
Cr. TRIANGLE
BAY
T I C
N
SBA137
ST20
O
O W
N S
L
L T
A
A
Hilo ve r
INTERCOASTAL
HWY
head
Jumping
HOPE
AREA
RD.
Run
ROAD
SNEADS
PARK
MIDWAY
NC
NAVAL
US
S T.
I
TERRACE
TA
RA
W A
BL
VD
K
NO
X
KNOX
TRW. PARK II
TARAWA
BLVD.
OFFICER
Northeast
PARADISE
BREWSTER
Creek
HOSPITAL
R ail
STORAGE
AREA
OPEN
roadH O
L C O
M B
Cr.
WATKINS
VILLAGE
Walla ce
RD.
LOUIS
RE
M
AIN
VICE
SER
RD.
INDUSTRIAL
AREA
B
LVD
QUARTERS
BLVD.
AREAN
W
Holmes Pt.
E
Hadros Pt.
ST
ON
E
HADNOT
POINT
AREA
RIV
POINT
W
ILLIAM
S
C am p Lejeune
CEM.
N G
LAND
I
R D.
M O
NTFO
RD
BayWilson
POINT
MONTFORD
Pt.
Pt.
Mumford
Brinson
Creek
A S
T.17
CURTISU
.S
. GEIGER
AREA-B
RT
MARINE CORPS
AIR STATION
ROAD
Pt.
Ragged
So ut hw es t
Cr.
isLew
Run Mill
CEM.
R ai lro ad
FIRE TOWER
VERONA
Cr ee k
Paradise
CREEK
AREA
Creek
FRENCH
French
C r.
Duck
I R
V
Pt.
Rhodes
Cr.
rshu t
White
Cr.
AREA
POINT
R E
MARINES
FERRY
Traps Bay
SNEADS
Hings Pt.
FIRE
BASE
AMPHIBIAN
AREA
C ou rth ou se
Jarrelts
R I V
Pt.
TOWER
Ferry
Pollocks Pt.
ENPt.
W
Snead's Cr. Bay
ENGINEER
ROAD
M ill
C r.
Cr.
ROADPOINT
Li ne
C oa st
Cr.
FIRE TOWER
Millstone
S ea bo ar d
M uddy
Store Bay
Everett Cr.
Cr.
Stone
R D
RAN
GE
R T.
U .S
. R T.
RHODES
RAG K2
Town
ROAD
ROAD
Cow
BA300
BA301
Mile Hammock Bay
Handpick Bay
RT.
N.C.
E R
P
IN
EY
G
R E
EN
R
D
MAGAZINE
COMBAT
TOWN
Camp Lejeune - Cherry Point Railroad
C H
U R
C H
ST.
7TH
6TH
NC 24
17/24
WILSON BLVD
AREA
GSRA
NEW RIVER
DOUGLASS RD
WALLACE CR RD
BIRCH ST
CG101 SITE GRADING PLAN
CU101 SITE UTILITY PLAN
CS501 DETAILS
CG501 DETAILS
DETAILSCU501
SITE
C-100 CIVIL NOTES, LEGEND AND ABBREVIATIONS
of 2911
S-001 GENERAL NOTES
S-101 FOUNDATION PLAN
S-401 ENLARGED PARTIAL FOUNDATION AND CONTROL CABIN FOUNDATION PLANS
SECTIONS AND DETAILSS-501
60033576 60033577 60033578 60033579 of 29 of 29 of 29 of 2921
CS102 ENLARGED SITE LAYOUT PLAN
CG102 ENLARGED SITE GRADING PLAN
CG502 DETAILS
of 291260033570
60033571 of 2913 of 291660033574 60033575 of 2917 of 291460033572 60033573 of 2915
MECHANICAL GENERAL NOTES, LEGEND, AND ABBREVIATIONSM-001
MECHANICAL SITE PLAN - DEMOLITIONMD101
MECHANICAL ENLARGED PLANS - DEMOLITIONMD401
MECHANICAL SITE PLAN - NEW WORKM-101
MECHANICAL ENLARGED PLANS - NEW WORKM-401
60033580 of 2922 MECHANICAL DETAILSM-501 60033581 of 2923 GENERAL NOTES, LEGEND AND ABBREVIATIONSE-001 60033582 of 2924 SITE PLAN - DEMOLITIONED101 60033583 of 2925 SITE PLAN - NEW WORKE-101 60033584 of 2926 SITE PLAN - NEW WORKE-102 60033585 of 2927 ELECTRICAL ENLARGED PLANS - NEW WORKE-401 60033586 of 2928 DETAILSE-501 60033587 of 2929 DETAILSE-502
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033560
CIVIL NOTES, LEGEND AND ABBREVIATIONS
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033561
SITE PLAN-EXISTING CONDITIONS AND DEMOLITION
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033562
SITE LAYOUT PLAN
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033563
ENLARGED SITE LAYOUT PLAN
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033564
SITE GRADING PLAN
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033565
ENLARGED SITE GRADING PLAN
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033566
SITE UTILITY PLAN
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033567
DETAILS
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033568
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033569
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
J. K. AVOLIS, P.E.
J. C. AVOLIS, P.E.
MSP / WFF
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
SPEC. 05-20-0071 29
NEW BERN, NC 28561
PH.(252) 633-0068
P.O. BOX 15564
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033570
GENERAL NOTES LEGEND AND ABBREVIATIONS
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
60033575
M-001
MECHANICAL GENERAL NOTES, LEGEND, AND
ABBREVIATIONS
T. HAHN
J. KULENGUSKI
C. LAMBERT
PUMP SCHEDULE
LIQUID PROPANE PUMP CONTROL SEQUENCE
MANUFACTURER'S RECOMMENDATIONS:
FUNCTIONAL PERFORMANCE TEST
04/30/2021
B
A
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033576
TN
PN
MECHANICAL SITE PLAN - DEMOLITION
MD101
MECHANICAL SITE PLAN - DEMOLITION
T. HAHN
J. KULENGUSKI
C. LAMBERT
NOTES THIS SHEET
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033577
TN
PN
MECHANICAL ENLARGED PLAN - DEMOLITIONA
MD401
MECHANICAL ENLARGED PLANS - DEMOLITION
TN
PN
MECHANICAL ENLARGED PLAN - DEMOLITIONB
T. HAHN
J. KULENGUSKI
B
A
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033578
TN
PN
MECHANICAL SITE PLAN - NEW WORK
M-101
MECHANICAL SITE PLAN - NEW WORK
CONDUIT NOTE:
T. HAHN
J. KULENGUSKI
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033579
TN
PN
MECHANICAL ENLARGED PLAN - NEW WORKA
M-401
MECHANICAL ENLARGED PLANS - NEW WORK
TNPN
MECHANICAL ENLARGED PLAN - NEW WORKB
T. HAHN
J. KULENGUSKI
C. LAMBERT
CONDUIT NOTE:
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033580
M-501
MECHANICAL DETAILS
PROPANE TANK SCHEMATIC FLOW DIAGRAMA
T. HAHN
J. KULENGUSKI
TYPICAL PIPE TRENCH DETAILDCONDUIT CONNECTION DETAILCPUMP PAD DETAILB
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033581
GENERAL NOTES, LEGEND AND ABBREVIATIONS
J. BARKLEY
M. LAPOINT
EQUIPMENT CONNECTION
JUNCTION BOX
MOTOR CONNECTION
ELECTRICAL PANELBOARD
ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TO
PANELBOARD (PANEL AND CIRCUIT DESIGNATION AS INDICATED). AS A
MINIMUM CONDITION, EACH SINGLE PHASE CIRCUIT SHALL HAVE 1 #12 PHASE
CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR AND 1 #12 GROUNDING
CONDUCTOR IN 1/2" CONDUIT. PROVIDE ADDITIONAL PHASE CONDUCTORS AS
REQUIRED FOR "MULTIPLE PHASED" ELECTRICAL LOADS. CONDUIT LARGER
THAN 1/2" AND CONDUCTORS LARGER THAN #12 SHALL BE AS INDICATED.
POWER
PAD MOUNTED TRANSFORMER
INDICATES FRONT
GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK
SHOWN ON ELECTRICAL DRAWINGS IS NEW WORK TO BE PROVIDED
UNDER THIS CONTRACT.
COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES ON
THE PROJECT. THE CONTRACTOR MUST REVIEW ALL CONTRACT
DOCUMENTS INCLUDING CIVIL AND STRUCTURAL DRAWINGS AND
SPECIFICATIONS. CONTRACTOR SHALL COORDINATE AND ADJUST
ACCORDINGLY AS DIRECTED BY THE CONTRACTING OFFICER.
AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL DRAWINGS
TO BE KEPT ON SITE AND MARK, DAILY, THE DRAWINGS IN RED AS THE
PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF
ALL DEVIATIONS BETWEEN THE WORK SHOWN ON THE DRAWINGS AND
THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKED DRAWINGS
SHALL REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE ORIGINAL
DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER THE MARKED
DRAWINGS TO THE ENGINEER AT PROJECT CLOSE-OUT.
INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL
REQUIRED INSPECTION CERTIFICATES TO THE CONTRACTING OFFICER.
J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT
MARKER IDENTIFYING CIRCUIT NUMBER AND PANELBOARD OF CIRCUITS
WITHIN.
WIRING DEVICES: LABEL ALL WIRING DEVICES WITH PANELBOARD AND
CIRCUIT DESIGNATION PERMANENTLY ATTACHED WITH BLACK TYPED
DESIGNATION ON CLEAR TAPE.
MOTOR COORDINATION: MOTORS, MOTOR STARTERS, CONTROLLERS,
INTEGRAL DISCONNECT SWITCHES, AND CONTACTORS SHALL BE
PROVIDED WITH THEIR RESPECTIVE PIECES OF EQUIPMENT BY THE
EQUIPMENT SUPPLIER. COMMUNICATE WITH THE TRADES PROVIDING THE
EQUIPMENT, VERIFYING ALL REQUIREMENTS, PROVIDE ALL ELECTRICAL
CONNECTIONS REQUIRED THEREIN, AND INSTALL MOTOR STARTERS.
MOTOR DISCONNECTS: ALL MOTORS SHALL HAVE DISCONNECTING
MEANS.
MOTOR CONTROLLERS: ALL 3-PHASE MOTORS SHALL HAVE MAGNETIC
MOTOR CONTROLLERS WITH SOLID STATE OVERLOAD RELAY
PROTECTION. THE SOLID STATE OVERLOAD RELAY SHALL HAVE PHASE
LOSS AND PHASE OVERCURRENT PROTECTION WITH AUTOMATIC RESET
UPON RETURN OF NORMAL POWER.
MOTOR FUSE PROTECTION: WHERE FUSE PROTECTION IS SPECIFICALLY
REQUIRED BY THE EQUIPMENT MANUFACTURER, PROVIDE FUSED
SWITCHES IN LIEU OF NON-FUSED SWITCHES OR IN LIEU OF ENCLOSED
CIRCUIT BREAKERS, OR OTHER DEVICES INDICATED.
CONNECTION DETAILS: SECURE APPROVED SHOP DRAWINGS SHOWING
WIRING DIAGRAMS, ROUGH-IN AND HOOK UP DETAILS FROM OTHER
INVOLVED CONTRACTORS FOR EQUIPMENT WHICH MUST BE CONNECTED
ELECTRICALLY.
COORDINATION DETAILS: MECHANICAL EQUIPMENT WILL BE FURNISHED
AND INSTALLED BY THE MECHANICAL CONTRACTOR. THE LOCATIONS
SHOWN ON THE ELECTRICAL DRAWINGS ARE APPROXIMATE. COORDINATE
WITH THE MECHANICAL CONTRACTOR TO DETERMINE THE EXACT
LOCATION OF EACH PIECE OF EQUIPMENT AND DETERMINE THE EXACT
ROUGH-IN AND CONNECTION REQUIREMENTS.
WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF ELECTRICAL
EQUIPMENT WITH MECHANICAL PIPING ETC. AND ASSURE WORKING
CLEARANCE REQUIRED BY NEC WILL BE MET. SUFFICIENT ACCESS AND
WORKING SPACE SHALL BE PROVIDED AND MAINTAINED AROUND
ELECTRICAL EQUIPMENT AS REQUIRED BY THE NATIONAL ELECTRICAL
CODE. CONTRACTOR SHALL COORDINATE FINAL LOCATION OF EQUIPMENT
PROVIDED AND INSTALLED BY OTHER TRADES.
STARTER MOUNTING: WHERE AN INDIVIDUALLY MOUNTED SAFETY
SWITCH, STARTER OR CIRCUIT BREAKER IS SHOWN ADJACENT TO ITS
RESPECTIVE LOAD AND NOT MOUNTED ON A WALL, PROVIDE ALL
SUPPORTS, BRACKETS, ANCHORING, ETC. NECESSARY TO PROPERLY
SUPPORT THE DEVICE.
MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE
FINISHED GRADE TO THE CENTERLINE OF THE WIRING DEVICE UNLESS
OTHERWISE NOTED.
CLEAN UP: ON PROJECT CLOSE-OUT CLEAN ALL ELECTRICAL DEVICES
AND REMOVE ALL PAINT SPATTERS FROM DEVICES, FIXTURES AND
PLATES.
GENERAL ELECTRICAL NOTES ELECTRICAL LEGEND
AND
T
E
J
DUPLEX CONVENIENCE RECEPTACLE 20A, 120V, 18" AFF, UON
· GFI: GROUND FAULT INTERRUPTING TYPE RECEPTACLE
· WP: WEATHER RESISTANT GFI RECEPTACLE WITH WEATHERPROOF
WHILE-IN-USE COVER.
ABBREVIATIONS
A AMPERE
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
BFG BELOW FINISHED GRADE
C CONDUIT
EC EMPTY CONDUIT
ETR EXISTING TO REMAIN
FLA FULL LOAD AMPS
GFI GROUND FAULT INTERRUPTER
GND GROUND
HP HORSE POWER/HEAT PUMP
KAIC THOUSAND AMPERE
INTERRUPTING CAPACITY
KVA KILO-VOLT-AMPERES
KW KILO-WATTS
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MLO MAIN LUGS ONLY
NEC NATIONAL ELECTRICAL CODE
NF NON-FUSED
NIC NOT IN CONTRACT
NTS NOT TO SCALE
P POLE
PF POWER FACTOR
Ø PHASE
PRI PRIMARY
SE SERVICE ENTRANCE
SEC SECONDARY
SPD SURGE PROTECTION DEVICE
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VOLT
W WATTS/WIRE
WP WEATHERPROOF
THE FOLLOWING SUBSCRIPTS SHALL APPLY TO RECEPTACLES WHERE USED:
EUP EXISTING UNDERGROUND PRIMARY CIRCUIT, 7.4KV
EUS EXISTING UNDERGROUND CIRCUIT
ELECTRICAL SERVICE RACK
CONTROLS CABINET
MANHOLE. REFER TO DETAIL THIS SHEET.
CC
MH
ESR-X
EOH EXISTING OVERHEAD PRIMARY CIRCUIT
OHE OVERHEAD PRIMARY CIRCUIT
A
TOP, SIDES & BOTTOM
#5 REINF. AT 6" EW
AND FIG. 12, SIZE 28 RESPECTIVELY
FED. SPEC. A-A-60005 FIG. 4, SIZE 28
FOR MANHOLE FRAME & COVER, SEE
SECTION A-A
BC 6"
WITH CEMENT MORTAR
BRICK COLLAR LINED UP
GROUND ROD & CLAMP
10"
SLOPE 1:40
7/8" Ø PULLING-IN IRON
DUCT ENTRANCE
6"
A
7/8" Ø PULLING-IN IRON
DUCT ENTRANCE
DEEP SUMP
12" x 12" x 10"
PLAN
MANHOLE DIMENSIONS
TYPE
A B C (AT HIGH PT.)
6"
6" 1'-0"
6"
6"
6"
6'-0" 6'-0" 6'-6"
A
B
TO SUMP
LAP REINF. 24" (TYP.)
WATERSTOP AT ALL
CONSTR. JTS. (TYP.)
NOTES:
FOR DETAILS OF CABLE RACKS,
DUCT ENTRANCE AND PULLING-IN
IRONS, SEE PLATE UG-7.
MINIMUM CONCRETE COMPRESSIVE
STRENGTH SHALL BE 3000 PSI.
1.
2.
UG-1JUNE 2002
TYPES 1 & 2
STANDARD ELECTRICAL MANHOLE (NONTRAFFIC)
SKETCH DATE STYLE
6'-6"8'-0"6'-0"
WALL OF MANHOLE
TYPICAL CABLE RACK
TYPICAL DUCT ENTRANCE
DUCT
INSIDE FACE
OF MANHOLE
45°
3"
DETAIL OF PULLING-IN IRON
7" MIN.
7" MIN.
8 3/8"
7/8"Ø
9"
CAST IN PLACE
3"
1 1/2"
CONCRETE WALL
LOCKWASHER
FILLET WELD
2 1/2"Ø WASHER
6 1/2" X 2 1/2" X 3/16" PLATE
ALTERNATE METHOD
CL
(MIN)
2 1/2" RAD
1"Ø U-BOLT
1"Ø NUT
1 1/4"Ø SLEEVE
13/16"
3/16" 4"
NOTE
ALL METAL PARTS SHALL
BE HOT DIP GALVANIZED
UG-7JUNE 2002
(PULLING-IN IRONS, CABLE RACK AND DUCT ENTRANCE)
DETAILS
SKETCH DATE STYLE
FINISHED GRADE
30" MINIMUM
3000 PSI CONCRETE
5"C, PVC, TYPE
"EB" (POWER)
BASE AND INTERMEDIATE
SPACERS 48" ON CENTER
MASONRY LEVELING BLOCKS AT
BASE SPACERS AS NEEDED
DUCTBANK
MARKING TAPE
TYPICAL
#4 REBAR (TYPICAL)
#4 REBAR (TYPICAL) 18" ON
CENTER
3" MINIMUM (TYPICAL)
3" MINIMUM SEPARATION (TYPICAL)
1-1/2" MINIMUM (TYPICAL)
EQUAL
EQUAL
COMPACTED BACKFILL. SEE
SPECIFICATION 31 23 00.00 20
FOR REQUIREMENTS.
4" DETECTABLE WARNING
TAPE, YELLOW
SIZE AND QUANTITY AS
INDICATED
#12AWG COPPER SOLID THW
TRACER WIRE
12" MINIMUM
FINISH GRADETRENCH WIDTH
6"
MI
NI
MU
M
LIDDED BELOW GROUND PILOT
CONNECTION BOX BY CIVIL
TYPICAL 4" UNDERGROUND SERVICE CONDUIT
MIN 36" CONDUIT RADIUS REQUIRED
FOR PULL THROUGH OF SERVICES
CONDUIT CONNECTION DETAIL
NO SCALEC
DUCTBANK DETAIL
NO SCALEA
TRENCH DETAIL (GRASS AREA)
NO SCALEB
PANELBOARD FT SCHEDULE
SEE POWER RISER DIAGRAM FOR RATINGS
LOAD (AMPS) BKR CKT PHASE CKT BKR LOAD (AMPS)
LOAD SERVED A B C TRIP NO. A B C NO. TRIP A B C LOAD SERVED
SPARE 20/1P 1 2 20/1P SPARE
SPARE 20/1P 3 4 20/1P SPARE
SPARE 20/1P 5 6 20/1P SPARE
SPARE 20/1P 7 8 20/1P SPARE
SPARE 20/1P 9 10 20/1P SPARE
SPARE 20/1P 11 12 20/1P SPARE
SPARE 20/1P 13 14 20/1P SPARE
SPARE 20/1P 15 16 20/1P SPARE
SPARE 20/1P 17 18 20/1P SPARE
SPARE 20/1P 19 20 20/1P SPARE
SPARE 20/1P 21 22 20/1P SPARE
SPARE 20/1P 23 24 20/1P SPARE
SPARE 20/1P 25 26 20/1P SPARE
SPARE 20/1P 27 28 20/1P SPARE
SPARE 20/1P 29 30 20/1P SPARE
SPARE 20/1P 31 32 20/1P SPARE
SPARE 20/1P 33 34 20/1P SPARE
SPARE 20/1P 35 36 20/1P SPARE
SPARE 20/1P 37 38 20/1P SPARE
SPARE 20/1P 39 40 20/1P SPARE
SPARE 20/1P 41 42 20/1P SPARE
TOTAL 0.0 0.0 0.0 0.0 0.0 0.0 TOTAL
TOTAL CONNECTED AMPS A: 0.0 B: 0.0 C: 0.0
PANELBOARD A SCHEDULE
SEE POWER RISER DIAGRAM FOR RATINGS
LOAD (AMPS) BKR CKT PHASE CKT BKR LOAD (AMPS)
LOAD SERVED A B C TRIP NO. A B C NO. TRIP A B C LOAD SERVED
RECEPTACLE 1.5 20/1P 1 2 20/1P SPARE
RECEPTACLE 1.5 20/1P 3 4 20/1P SPARE
SPARE 20/1P 5 6 20/1P SPARE
SPARE 20/1P 7 8 20/1P SPARE
SPARE 20/1P 9 10 20/1P SPARE
SPARE 20/1P 11 12 20/1P SPARE
SPARE 20/1P 13 14 20/1P SPARE
SPARE 20/1P 15 16 20/1P SPARE
SPARE 20/1P 17 18 20/1P SPARE
TOTAL 1.5 1.5 0.0 0.0 0.0 0.0 TOTAL
TOTAL CONNECTED AMPS A: 1.5 B: 1.5 C: 0.0
PANELBOARD MDP SCHEDULE
SEE POWER RISER DIAGRAM FOR RATINGS
LOAD (AMPS) BKR CKT PHASE CKT BKR LOAD (AMPS)
LOAD SERVED A B C TRIP NO. A B C NO. TRIP A B C LOAD SERVED
SPARE 20/1P 1 2 70/3P 40.0 P-1
SPARE 20/1P 3 40.0
SPARE 20/1P 5 40.0
SPARE 20/1P 7 8 20/1P SPARE
SPARE 20/1P 9 10 20/1P SPARE
SPARE 20/1P 11 12 100/1P SPARE
PANEL A 0.7 30/3P 13 14 100/3P 0.0 PANEL FT
0.7 0.0
0.0 0.0
TOTAL 0.7 0.7 0.0 40.0 40.0 40.0 TOTAL
TOTAL CONNECTED AMPS A: 40.7 B: 40.7 C: 40.0
E-001
K. MEARS
ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS FOR THE INTENDED PURPOSE. USE THE
MORE STRINGENT METHODS WHEN MANUFACTURER'S RECOMMENDATIONS, AND
PLANS & SPECIFICATION REQUIREMENTS DIFFER. BRING ANY CONFLICTS
BETWEEN MANUFACTURER'S RECOMMENDATIONS AND PLANS & SPECIFICATION
REQUIREMENTS TO THE GOVERNMENT'S ATTENTION.
MANUFACTURER'S RECOMMENDATIONS:
DEMONSTRATE THAT ALL SYSTEM COMPONENTS HAVE BEEN INSTALLED, THAT
EACH CONTROL DEVICE AND ITEM OF EQUIPMENT OPERATES, AND THAT THE
SYSTEMS OPERATE AND PERFORM, INCLUDING INTERACTIVE OPERATION
BETWEEN SYSTEMS, IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
PROVIDE ALL MATERIALS, SERVICES, AND LABOR REQUIRED TO PERFORM THE
FUNCTIONAL PERFORMANCE TESTS. PROVIDE A FUNCTIONAL PERFORMANCE
TESTING REPRESENTATIVE FOR EACH SUB-CONTRACTOR ASSOCIATED WITH THE
SYSTEMS TO BE TESTED. EACH REPRESENTATIVE IS RESPONSIBLE FOR
COORDINATION OF THEIR RESPECTIVE SUB-CONTRACTOR'S EXECUTION OF THE
PERFORMANCE TESTING ACTIVITIES.
CONDUCT INITIAL FUNCTIONAL PERFORMANCE TESTS AS SOON AS ALL
CONTRACT WORK IS COMPLETED. CORRECT ALL DEFICIENCIES IDENTIFIED
THROUGH ANY PRIOR REVIEW, INSPECTION, OR TEST ACTIVITY BEFORE THE
START OF FUNCTIONAL PERFORMANCE TESTS. FUNCTIONAL PERFORMANCE
TESTS MUST BE PERFORMED WITH THE SIMULATOR EQUIPMENT PROVIDER
PRESENT AND FULLY COORDINATED TO ENSURE A COMPLETE AND OPERABLE
SYSTEM. THE GOVERNMENT RESERVES THE RIGHT TO WITNESS ALL TESTS.
COORDINATE TEST SCHEDULE WITH GOVERNMENT REPRESENTATIVES AND
SIMULATOR EQUIPMENT PROVIDER.
FUNCTIONAL PERFORMANCE TEST
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SYM
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text DISCLOSURE OF INFORMATION THE CONTRACTOR SHALL COMPLY AS FOLLOWS: A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF THE MEDIUM (E.G. FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS 1. THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR 2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE. B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE OF RELEASE. C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
AutoCAD SHX Text 748 Lord Dunmore Dr., #101, Virginia Beach, VA 23464
AutoCAD SHX Text tel 757-474-0612 fax 757-474-0919
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
JAMES E. BARKLEY, JR.
AutoCAD SHX Text Lic. No. 043854
AutoCAD SHX Text
AE PROJECT # 20041
T ESR
CC
WPREMOVE EXISTING 25KVA,
12.47KV - 120/240V PAD
MOUNTED TRANSFORMER.
REMOVE EXISTING UNDERGROUND
PRIMARY BACK TO EXISTING
HANDHOLE.
EUS
EUP
EUS
REMOVE EXISTING CIRCUIT COMPLETE.
MH
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033582
TN
PN
SITE PLAN - DEMOLITION
SITE PLAN - DEMOLITION
REMOVE EXISTING ELECTRICAL SERVICE RACK, PANELBOARD,
ON/OFF SWITCH, AND RECEPTACLE COMPLETE BACK TO SOURCE.
REMOVE EXISTING FIRE TRAINER CONTROLS CABINET AND
ASSOCIATED CONDUIT AND WIRE COMPLETE BACK TO SOURCE.
REMOVE EXISTING FUEL PUMP AND ASSOCIATED STARTER AND
DISCONNECT COMPLETE. REMOVE WEATHERPROOF RECEPTACLE
AND UTILITY RACK COMPLETE.
NOTES THIS SHEET
1" = 30'-0" 30' 15' 0' 60'30' 90'
ED101
ELECTRICAL DEMOLITION NOTES
GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND FIELD INVESTIGATION
PRIOR TO DEMOLITION. VISIT THE EXISTING BUILDING PRIOR TO BID IN ORDER TO BECOME
FAMILIAR WITH THE EXISTING CONDITIONS AND IN ORDER TO AVOID CONFLICTS.
DASHED ITEMS: ALL ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE EXISTING AND SHALL BE
REMOVED.
SOLID ITEMS: ALL ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING TO REMAIN.
CIRCUITING TO REMAIN: EXISTING CIRCUITING TO REMAIN SHALL BE REROUTED OR
RECONNECTED, AS REQUIRED, WHERE AFFECTED BY NEW WORK IN ORDER TO MAINTAIN
CONTINUITY OF THE CIRCUIT.
REUSE OF EXISTING CIRCUITRY: EXISTING CIRCUITRY SERVING LIGHTING FIXTURES AND/OR
RECEPTACLES FOR A GIVEN AREA SHALL BE REUSED WHERE INDICATED TO SERVE THE NEW
LAYOUT. PROVIDE CIRCUIT MODIFICATIONS INDICATED OR AS OTHERWISE REQUIRED TO
MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS THAT REMAIN.
EXISTING CONDUIT: ALL EXISTING CONDUITS AND WIRING THAT WILL NOT BE REUSED SHALL BE
REMOVED WHERE THEY WILL BE EXPOSED UPON COMPLETION OF NEW WORK. EXISTING
CONDUIT TO REMAIN BELOW FLOOR SLAB SHALL BE CUT OFF ONE INCH BELOW ROUGH FLOOR
AND GROUTED FLUSH. ALL EXISTING WIRING IN CONDUITS TO BE ABANDONED SHALL BE
DISCONNECTED FROM POWER SOURCE AND REMOVED.
REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS. REPAIR, AT NO
ADDITIONAL COST TO THE OWNER, ANY DAMAGE CAUSED TO EXISTING CONSTRUCTION AND/OR
EQUIPMENT TO REMAIN.
ASSOCIATED APPURTENANCES: REMOVE ALL ELECTRICAL APPURTENANCES (DISCONNECTS,
STARTERS, WIRING, CONDUIT, ETC.) ASSOCIATED WITH ITEMS TO BE REMOVED INCLUDING
EQUIPMENT TO BE REMOVED BY OTHERS.
KNOCKOUT PLUGS AND COVERS: ALL CONDUIT REMOVED SHALL BE REMOVED IN ITS ENTIRETY,
INCLUDING FITTINGS, MOUNTING DEVICES, MOUNTING HARDWARE, ETC. PROVIDE CONDUIT
PLUGS AND BLANKS FOR ALL OPENINGS CREATED BY THE REMOVAL OF CONDUIT. PROVIDE
BLANK COVER PLATES FOR ALL OPENED OUTLET BOXES CREATED BY THE REMOVAL OF
EQUIPMENT AND/OR DEVICES
DEMOLISHED MATERIALS: ALL MATERIALS REMOVED UNDER DEMOLITION, NOT TO BE RELOCATED
OR DESIGNATED TO BE TURNED OVER TO THE OWNER, SHALL BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE REMOVED COMPLETELY FROM THE SITE.
SCHEDULE OUTAGES: ALL WORK AND ALL POWER OUTAGES IN THE EXISTING BUILDING SHALL BE
SCHEDULED AT TIMES CONVENIENT TO THE OWNER.
NOTIFICATION: NOTIFY THE OWNER PRIOR TO TURNING OFF ANY CIRCUITS.
J. BARKLEY
M. LAPOINT
K. MEARS
T
150KVA, 12.47-208/120V, PAD
MOUNTED TRANSFORMER
PANEL "FT"
MATCHLINE E-102
1 2
ESR-2
SEE CONTINUATION
ON SHEET E-401
P-1; 30HP, 480V, 3Ø
WP
A-1
MDP-2 ; 3 #4, 1
#8 GND, 1 1/2"C 1
A E-401
WP
A-3
(3) 4" EC WITH PULL STRING FROM
CONTROL BUILDING TO FIRE
TRAINER. COORDINATE EXACT
STUB UP LOCATIONS WITH
TRAINER VENDOR DRAWINGS. ESR-1
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033583
TN
PN
SITE PLAN - NEW WORK
SCALE: 1" =30'
E-101
SITE PLAN - NEW WORK
RUN CIRCUIT VIA MOTOR DISCONNECT AND STARTER.
SEE RISER DIAGRAM ON SHEET E-501 FOR SIZES AND QUANTITY.
NOTES THIS SHEET
1" = 30'-0" 30' 15' 0' 60'30' 90'
ELECTRICAL SERVICE RACK "FL1" ELEVATION VIEW
FINISH GRADE
CONCRETE
ENCASEMENT
24", TYP.
3" DIAMETER
GALVANIZED
STEEL PIPE
SCHEDULE 40
WITH CAP, TYP.
1-5/8" X 1-5/8" X 12 GAUGE
GALVANIZED FRAMING
CHANNEL. MOUNT WITH
U-BOLTS (TYP)
PANEL
A
60A MCB
208/120V 3Ø, 4W
4X
3500 lb
CONCRETE
T1
15KVA
480-208/120V 3Ø 4X
PANEL
MDP
225A MCB
480/277V 3Ø, 4W
4X
ESR-1
ELECTRICAL SERVICE RACK "FL1" ELEVATION VIEW
FINISH GRADE
CONCRETE
ENCASEMENT
24", TYP.
3" DIAMETER
GALVANIZED
STEEL PIPE
SCHEDULE 40
WITH CAP, TYP.
1-5/8" X 1-5/8" X 12 GAUGE
GALVANIZED FRAMING
CHANNEL. MOUNT WITH
U-BOLTS (TYP)
3500 lb
CONCRETE
DISCONNECT
100A-3P
FU@70A
4X
ESR-2
MOTOR
STARTER
WEATHERPROOF GFI
RECEPTACLE WITH
IN-USE COVER
WEATHERPROOF
GFI RECEPTACLE
WITH IN-USE COVER
PROVIDE A CATHODIC PROTECTION SYSTEM IN ACCORDANCE WITH
SPECIFICATION SECTION 26 42 14.00 10
CATHODIC PROTECTION NOTE:
DUCTBANK CABLE SCHEDULE
DESIGNATION DUCT SIZE (IN.) CONDUCTORS/ DESCRIPTION
1 5" 4 #2 - 15KV
2 5" 1/4" NYLON PULL ROPE
J. BARKLEY
MATCHLINE E-101
OHE
EXISTING POLE 70297-43951 (3-45)
EXISTING X-AB, 15FDE3-N AND 15VDE1-N
PROVIDE 15FDDE3-N
EXISTING U.G. TERMINAL 3 PHASE
EXISTING RISER (4" GRS)
EXISTING GUY AND ANCHOR
EXISTING POLE 70296843931 (3-45)
EXISTING 15VDE1-N
PROVIDE X-AB
PROVIDE 15FDDE3-N
EXISTING U.G. TERMINAL SINGLE PHASE
EXISTING RISER (4" GRS)
EXISTING GUY AND ANCHOR
PROVIDE POLE 70296843932 (3-45)
PROVIDE X-AB, 15VDE3-N
PROVIDE U.G. TERMINAL 3 PHASE
PROVIDE RISER (TYPE B, 4" GRS)
PROVIDE GUY AND ANCHOR
EOH
EOH
1 2
MH
SEE E-101 FOR
CONTINUATION
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033584
TN
PN
SITE PLAN - NEW WORK
E-102
SITE PLAN - NEW WORK
NOTES THIS SHEET
1" = 30'-0" 30' 15' 0' 60'30' 90'
DUCTBANK CABLE SCHEDULE
DESIGNATION DUCT SIZE (IN.) CONDUCTORS/ DESCRIPTION
1 5" 4 #2 - 15KV
2 5" 1/4" NYLON PULL ROPE
J. BARKLEY
SEE CONTINUATION ON
SHEET E-101
2 2
SHEET
CODE IDENT. NOSIZE
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033585
TNPN
ELECTRICAL ENLARGED PLAN - NEW WORKA
E-401
ELECTRICAL ENLARGED PLAN - NEW WORK
(3) 4" EC WITH PULL STRING FROM CONTROL BUILDING TO FIRE
TRAINER 24" BFG MINIMUM. COORDINATE EXACT STUB UP LOCATIONS
WITH TRAINER VENDOR DRAWINGS.
2" CONDUIT WITH 1/4" NYLON PULL ROPE.
PILOT CONNECTION BOX.
NOTES THIS SHEET
3/16" = 1'-0" 0' 5' 10' 20'M-101
CONDUIT ROUTING NOTE:
J. BARKLEY
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033586
DETAILS
E-501
X0
SECTION B-B
10"
SECTION A-A
78" 58"10" 10"
3"
2"
5/8" 5"
9" 6"
5/8" LIFTING
INSET (4)
5 5/8" 18"23 5/8"
4"
78"
4"
A
A
B
B
58"
TRANSFORMER BOX PAD BASIS OF
DESIGN: PARKER BUMPER COMPANY.
ITEM NO. 7624-24
GRADE
GRADE
CONTRACTOR SHALL COORDINATE OPENING
DIMENSION FOR TRANSFORMER PURCHASED
WITH PARKER BUMPER COMPANY PRIOR TO
ORDERING PRE-CAST PAD
(AB
OV
E G
RA
DE
MI
N.
SURGE
ARRESTERS
CURRENT TRANSFORMERS (1200/5)
3-POLE FUSE BLOCK
WATTHOUR DEMAND METER: TO
CONFORM TO BASE STANDARDS.
ITRON V&I CS3 SERIES METER.
SECONDARY
COMPARTMENT
LOW VOLTAGE CABLE
TERMINATIONS
GROUND PAD (TYP OF 2)
TRANSFORMER BOX PAD
GRADE
SECONDARY CIRCUIT
GROUND ROD, TYP
OF 4, 1 AT EACH
CORNER OF PAD.
600V INSULATION
#4/0 BARE COPPER GROUND LOOP
ENCIRCLING ENTIRE CONCRETE
PAD. MIN 18" BELOW FINISHED
GRADE.
2'-0"
MIN
PRIMARY CIRCUIT
CABLE WELL
LOOP FEED
CONNECTOR
LOAD BREAK
CONNECTOR
PRIMARY NEUTRAL
BUSHING INSERT
TRANSFORMER
BUSHING WELL
OIL-IMMERSED
CURRENT-LIMITING
FUSES
2 POSITION LOAD
BREAK OIL SWITCH
PRIMARY COMPARTMENT
BAYONET OIL-IMMERSED
EXPULSION FUSES
#4/0 BARE
#4/0, 600V
INSULATION
WHD
2 1 /2"
6 1 /2"
1 1 /2"2 5/8"
5 5/8" 18"
9"
REMOVE EXISTING 25KVA
7.2KV-120/240V, 1Ø, 3W
PAD MOUNTED TRANSFORMER
REMOVE
PANEL
FT
100A MCB
120/240V 1Ø, 3W
REMOVE EXISTING PRIMARY
FEEDER BACK TO SOURCE
REMOVE EXISTING FEEDER,
COMPLETE
150KVA 12.47KV-208/120V, 3Ø, 4W PAD
MOUNTED TRANSFORMER
PANEL
FT
100A MCB
480/277V 3Ø, 4W
4X
22KAIC
PANEL
MDP
225A MCB
480/277V 3Ø, 4W
4X
22KAIC
15KVA
480-208/120V
3Ø 4X
PANEL
A
60A MCB
208/120V 3Ø, 4W
4X
10KAIC
POWER RISER DIAGRAM - DEMOLITION
NO SCALEB
POWER RISER DIAGRAM - NEW WORK
NO SCALEC
PAD MOUNTED TRANSFORMER DETAIL
NO SCALEA
TRANSFORMER PAD DETAIL
NO SCALED
N
#2 GND
4 #4/0 - 4"C 4 #2, 1 #8 GND -
1 1/4"C
3 #10, 1 #10 GND -
1/2"C
4 #6, 1 #8 GND -
1"C
G
NOTES THIS SHEET
EXISTING 12.47KV OVERHEAD PRIMARY UTILITY
EXISTING UTILITY POLE
TO REMAIN
EXISTING UTILITY POLE
TO REMAIN
PROVIDE UTILITY POLE
PROVIDE (3) 15KV, 100A
FUSED CUTOUT
DUCTBANK CABLE SCHEDULE
DESIGNATION DUCT SIZE (IN.) CONDUCTORS/ DESCRIPTION
1 5" 4 #2 - 15KV
2 5" 1/4" NYLON PULL ROPE
EXISTING 7.2KV SINGLE PHASE OVERHEAD PRIMARY UTILITY. EXTEND PRIMARY
OVERHEAD BASE UTILITY DISTRIBUTION PHASE CONDUCTORS FROM POLE 70297-43951
TO POLE 70296843931 IN ORDER TO PROVIDE 12.47KV, THREE PHASE. CONDUCTORS
SHALL MATCH EXISTING.
EXTEND 12.47KV, THREE PHASE OVERHEAD UTILITY TO POLE 70296843932. CONDUCTORS
SHALL MATCH EXISTING. COORDINATE FINAL POLE NUMBER WITH BASE.
13.2 34.5
S N
13.2
N 34.5
PLAN VIEW
POLE # (45'-3)
X-FB, 35FR3
X-FB, 15F3
TF (25KVA, 13.2 GRD. Y/7.6 KV - 120/240 V.)
S1, SDE2
GUY (5/16")
ANCHOR (10" SCREW) (12' GUY LEAD)
GROUND
NOTES
THE SYMBOLS LISTED ABOVE
INCLUDE MATERIALS (DESCRIBED
BY OVERHEAD SKETCHES) WHICH
ARE GRAPHICALLY ILLUSTRATED
BY THIS PICTURE. SEE
SKETCH OH-1.3A FOR
EXPLANATORY NOTES.
EACH SKETCH CONTAINS
MATERIAL ITEMS WHICH COMPRISE
A PART OF EACH INDIVIDUAL
SYMBOL REFERENCED BY THAT
SKETCH, THESE ITEMS ARE
INDICATED BY CIRCLED
NUMERALS WHICH ARE IDENTIFIED
BY SKETCHES OH-1.5
AND OH-1.5A.
SPACING REQUIREMENTS RELATED
TO INDIVIDUAL COMPONENTS OF
A SYMBOL ARE INDICATED ON
THE APPROPRIATE SKETCH.
VERTICAL SPACING
REQUIREMENTS BETWEEN
CIRCUITS AND/OR SYSTEMS
ARE INDICATED ON SKETCH
OH-1.4. ALL OTHER
SEPARATIONS BETWEEN
CIRCUITS, EQUIPMENT, ETC.,
SHALL CONFORM TO THE
NATIONAL ELECTRICAL
SAFETY CODE, IEEE C2.
1.
2.
3.
OH-1.3JUNE 2002SKETCH DATE STYLE
METHOD OF SHOWING SYMBOLS
UNDERBUILD CIRCUIT
POSITION OF COMMON NEUTRAL
OR MULTIPLEX SECONDARY
CONDUCTOR
CIRCUITCOMM.
PROVIDE 60" CLEARANCE WHEN OPERATING VOLTAGE OF UNDERBUILD
CIRCUIT IS GREATER THAN 15KV.
NOTE
FOR HORIZONTAL SPACING REQUIREMENTS FOR CONDUCTORS ON SAME SUPPORT,
REFER TO THE NATIONAL ELECTRICAL SAFETY CODE, IEEE C2.
1.
Ø-Ø VOLTAGE 0-15KV 15-50KV
SPACING A"
SPACING B"
40" 40"
48" 40"
OH-1.4JUNE 2002SKETCH DATE STYLE
BASIC VERTICAL SPACING REQUIREMENTS
"B"
"A"
40" MIN.
DEDICATED
CLEAR SPACE
POSITION OF LOWEST POWER (SUPPLY)
ATTACHMENT SHALL BE NO LESS THAN
24'-4" ABOVE GRADE.
DEDICATED CLEAR SPACE BETWEEN
POWER (SUPPLY) AND COMMUNICATION
CIRCUITS.
POSITION OF HIGHEST
COMMUNICATION ATTACHMENT
SHALL BE NO HIGHER THAN
21'-0" ABOVE GRADE.
POLE LINE MATERIAL LIST
FLAT STEEL BRACE (TWO PIECES)
MACHINE BOLT, 3/8" X LENGTH NEEDED WITH WASHER, NUT AND LOCKWASHER
8' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 3 1/2" X 4 1/2"
MACHINE BOLT, 5/8" X LENGTH NEEDED WITH WASHER, NUT AND LOCKWASHER
TIMBER CONNECTOR
LAGSCREW, 1/2" X 4"
ANGLE STEEL BRACE (TWO PIECES)
MACHINE BOLT, 1/2" X LENGTH NEEDED, WITH WASHER, NUT & LOCKWASHER
DEADEND BOX
STEEL PIN
PIN INSULATOR
GRID GAIN, USED ONLY WHEN THERE IS NO POLE GAIN
ANGLE STEEL BRACE (ONE PIECE)
10' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 3 1/2" X 4 1/2"
5/8" EYE NUT
5/8" EYE BOLT, LENGTH AS NEEDED, WITH WASHER, NUT & LOCKWASHER
EXTENSION LINK
BELL TYPE SUSPENSION INSULATOR WITH CONNECTING HARDWARE
STRAIN CLAMP
STEEL ANGLE PIN
CLUSTER MOUNTING BRACKET, STEEL
TRANSFORMER GROUNDING CONNECTION
STIRRUP
SECONDARY LEAD SUPPORT BRACKET
ADAPTER PLATE FOR CLUSTER MOUNTING
CLEVIS BRACKET FOR SPOOL INSULATOR
SPOOL INSULATOR
U BOLT CLAMP
PREFORMED GUY GRIP
GUY HOOK
GUY STRAIN INSULATOR
GUY WIRE, SIZE AS SPECIFIED
#4 WP CU. SOFT DRAWN GROUND WIRE
GROUND CLAMP
CONDUIT COUPLING
CONDUIT BEND
INSULATED BUSHING
PERFORATED STRAPPING, 1-1/2" WIDE
HOT LINE CLAMP
FUSED CUTOUT, AS SPECIFIED
SURGE ARRESTER, AS SPECIFIED
POLE TOP PIN (RIDGE PIN) - 24 INCHES LONG
CROSSARM ANGLE PIN
ANGLE POLE TOP PIN
WEATHERPROOF SOFT DRAWN WIRE-SIZE
T0 MATCH OR EXCEED AMPACITY OF CONNECTING
CABLE, OR
AT 125% OF TRANSFORMER FULL LOAD
CURRENT, BUT NOT LESS THAN NO. 4 AWG
(a)
(b)
OH-1.5JUNE 2002SKETCH DATE STYLE
POLE LINE MATERIAL LIST
POLE LINE MATERIAL LIST
TRI-MOUNT BRACKET
TERMINATOR
MOUNTING BRACKET
CABLE GRIP HANGER
HOSE CLAMP
STUD, 3/4" X 1-3/4"
LINE POST INSULATOR
TRIPLE INSULATOR BRACKET
ANGLE CLAMP
INSULATOR, LINE POST CLAMP
4' CROSSARM
CROSSARM GAIN BRACKET
PULLEY BRACKET
WEDGE CLAMP
MIDSPAN SERVICE CLAMP
STUD, 7"
SADDLE, ANGLE
SADDLE CROSSARM
FITTING, POLE TOP
CONNECTOR
SUSPENSION CLAMP
TIE, SERVICE CABLE
54" FIBERGLASS STRAIN INSULATOR
69 PVC RISER SHIELD
PVC EXTENSION SHIELD
PVC BACK PLATE
72 8' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 4 3/4" X 5 3/4"
73 10' WOOD CROSSARM WITH CROSS SECTION DIMENSIONS OF 4 3/4" X 5 3/4"
OH-1.5AJUNE 2002SKETCH DATE STYLE
POLE LINE MATERIAL LIST
BACK-UP CURRENT LIMITING FUSE74
J. BARKLEY
SCALE: NOTED
80091F
DES.
CHK.
DESIGN DIR.
DR.
APPROVED: PWO OR OICC
SATISFACTORY TO:
SUBMITTED BY:
CAMP LEJEUNE, NORTH CAROLINA
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
MARINE CORPS BASE
NAVFAC DRAWING NO.DATE
DATE
OF
T. H. BURTON, P.E.
CONSTR. CONTR. NO. N40085-20-B-0071
SPEC. 05-20-0071 29
NRW ENGINEERING, P.C.
Consulting Structural Engineers
CONSTRUCT ARFF FIRE TRAINER PAD, SAS3455,
MCAS NEW RIVER
04/30/2021 60033587
DETAILS
E-502
ELEVATIONS
PLAN VIEW
NOTE
DRAWING INDICATES SYMBOL DX-AB. SUBSTITUTE 1
FOR 7 ON SYMBOL DX-FB.
OH-4JUNE 2002
DX-FB
DX-AB
SKETCH DATE STYLE
3'-2" 88
6 1/2" 6 1/2"
8'-0"
1'-6"
1'-0"
SEE NOTES 4 & 5
PLAN VIEW
ELEVATION
Ø-Ø VOLTAGE 0-15KV 15-50KV
SPACING "A" 40" 48"
NOTES
DRAWING REPRESENTS SYMBOL FDE3-N. ELIMINATE INSULATOR
ASSEMBLY FOR MIDDLE PHASE ON SYMBOLS FDE2 AND FDE2-N.
OMIT ITEMS 4 , 26 27 AND 28 FOR NEUTRAL ON FDE2
AND FDE3.
FOR NEUTRAL CONDUCTOR LARGER THAN #2 AWG,
SUBSTITUTE 19 FOR 26 , 27 AND 28 .
MODIFY THE NEUTRAL SPACING "A" AS INDICATED ON OTHER
SKETCHES FOR TRANSFORMER AND U.G. TERMINAL INSTALLATIONS.
NEUTRAL POSITION
1.
2.
3.
4.
5.
DRAWING REPRESENTS DEADEND ASSEMBLY FOR CIRCUIT VOLTAGES >5KV
AND <15KV. REFER TO SPECIFICATIONS SECTION 16301 FOR NUMBER
AND CLASS OF INSULATORS REQUIRED FOR EACH VOLTAGE LEVEL.
OH-15JUNE 2002
(0-50KV)
FDE3-N, FDE3, FDE2-N, FDE2
SKETCH DATE STYLE
2827264 "A"
6 1/2"6 1/2" PLAN VIEW
ELEVATIONS
NOTE
DRAWING INDICATES SYMBOL X-FB.
SUBSTITUTE 7 FOR 1 ON SYMBOL
X-AB.
OH-2JUNE 2002
X-AB
X-FB
SKETCH DATE STYLE
8'-0"
3'-2"
4"
1'-6"
ELEVATIONS
PLAN VIEW
TENSION AT "A" - 1200 LBS
MAXIMUM ALLOWABLE CONDUCTOR
NOTE
DRAWING INDICATES SYMBOL X-DE-FB. SUBSTITUTE 7
FOR 1 ON SYMBOL X-DE-AB.
OH-3JUNE 2002
X-DE-AB
X-DE-FB
SKETCH DATE STYLE
3 1515
424 2 3'-2"
6 1/2" 6 1/2"
8'-0"
1'-6"
4"
"A""A"
AT
TA
CH
ME
NT
PO
SIT
ION
OF
GU
Y
SE
E N
OT
E 3
SI
DE
VI
EW
FR
ON
T V
IEW
TH
IS
PO
LE
CO
NT
INU
ES
ON
BE
YO
ND
NE
UT
RA
L L
EV
EL
, IF
PO
LE
DE
AD
EN
DS
ON
TH
E
NE
UT
RA
L L
EV
EL
, IF
NO
TE
S
1.
2.
3.
OH-31JUNE 2002
(0-25KV)
U.G. TERMINAL
SKETCH DATE STYLE
45 40
49 65
2"
4" 40
MO
DIF
Y P
OS
ITI
ON
OF
TE
RM
INA
L O N D
EA
DE
ND
S T
O B E U
ND
ER
TH
E C
ON
DU
CT
OR
S
AN
D T
HE
CU
TO
UT
S O
N T
HE
BA
CK
SID
E O
F C
RO
SS
AR
M.
P
OL
E R
ISE
R M
US
T B
E
OF
FS
ET
TO
CL
EA
R N
EU
TR
AL
CL
EV
IS
BR
AC
KE
T.
CO
NN
EC
T B
OT
TO
M
LE
AD
OF
AR
RE
ST
ER
DI
RE
CT
LY
TO
PO
LE
GR
OU
ND
. I
NT
ER
CO
NN
EC
T
CA
BL
E I
NS
UL
AT
ION
SH
IEL
D D
RA
IN
WI
RE
S A
ND
CO
ND
UIT
RI
SE
R G
RO
UN
D T
O M
UL
TI-
GR
OU
ND
ED
NE
UT
RA
L (
IF
EX
IST
ING
) A
ND
PO
LE
GR
OU
ND
CU
TO
UT
PR
OV
IDE
S A
FU
SE
OR
A
SO
LID
BL
AD
E (
NO
N-F
US
ED
) O
PT
ION
CO
OR
DIN
AT
E W
ITH
SP
EC
IFI
C D
ES
IGN
RE
QU
IRE
ME
NT
S P
RO
VID
ED
GROUND LINE
SEE NOTE 3
SEE NOTES 1 & 2
OH-32JUNE 2002
GUY
GUY-I
SKETCH DATE STYLE
328'
MIN.
6'-0"
NOTES
DRAWING REPRESENTS SYMBOL FOR "GUY-I". OMIT ITEM 31 FOR THE "GUY"
SYMBOL.
ON CIRCUIT OPERATING VOLTAGES GREATER THAN 15KV, SUBSTITUTE 68 FOR 31 .
COORDINATE INSTALLATION WITH ANCHOR AS SPECIFIED.
UTILIZE ITEM 68 WHEN GUYING ATTACHMENT IS LOCATED IN THE PRIMARY AREA OF
THE POLE AS INDICATED BY SPECIFIC DESIGN REQUIREMENTS PROVIDED.
BOND ALL GUYS (SUPPLY & COMMUNICATION) AND CONNECT TO POLE GROUND AND
SYSTEM NEUTRAL (IF EXISTING).
1.
2.
3.
4.
5.
(SEE NOTE 1)
SERVICE CAP
CLAMP TYPE
SE
CO
ND
AR
Y C
ON
DU
CT
OR
NE
UT
RA
L O R T
OP
GRADE
FINISHED
GALVANIZED STEEL CONDUIT-SIZE AS INDICATED
SEE NOTE 3
SEE NOTE 2
CONDUIT LOCATION
OF TRAFFIC
DIRECTION
ROAD SIDE
POSITION
RISER
ALTERNATEPOSITION
RISER
POLE
1.
2.
3.
DIRECT BURIED
CABLE
DIRECT BURIED
CONDUIT
TYPE C
OH-35JUNE 2002
(SIZE & TYPE AS INDICATED)
CONDUIT RISER
SKETCH DATE STYLE
TYPE A
CONCRETE ENCASED
CONDUIT
TYPE B
18" MIN.
NOTES
ON CONDUIT RISER FOR PRIMARY CIRCUITS, ELIMINATE SERVICE CAP
AND PROVIDE GROUNDING TYPE INSULATING BUSHING.
BOND CONDUIT TO POLE GROUND AND SYSTEM NEUTRAL (IF EXISTING).
SEE GROUNDING NOTES ON SKETCH OH-41.
SPACE STRAPS AT MAXIMUM OF 4' INTERVALS.
ROAD SIDE
DIRECTION
OF TRAFFIC
ADDITIONAL
GROUND RODS
(WHEN REQUIRED)
PLAN
ALWAYS CONNECT THE POLE GROUND
LEAD(S) DIRECTLY TO THE NEUTRAL-
ENSURE THAT THE COPPER CONDUCTOR
WILL ALWAYS BE BELOW THE ALUMINUM.
CONNECTOR
NEUTRAL COPPERWELD STAPLES (TYP.)
GROUND
WIRE
POLE
ELEVATION
GROUND ROD
PLASTIC OR FIBER MOLDING
GALVANIZED STAPLES (TYPICAL)
FINISHED
GRADE
#4 BARE
COPPER
POLE
OH-41JUNE 2002SKETCH DATE STYLE
GROUND
24"
12"
ALTERNATE GROUND WIRE
POSITION. (USE WHEN
MULTIPLE GROUNDING
SYSTEMS ARE REQUIRED.)
(SEE NOTE 4)
1.
2.
3.
NOTES
USE ADDITIONAL GROUND RODS, WHEN REQUIRED,
TO OBTAIN RESISTANCE VALUE, AS REQUIRED BY
IEEE C2.
MAKE GROUNDING CONNECTIONS TO ALL EQUIPMENT
ON POLE AS REQUIRED BY IEEE C2.
FOR SYSTEMS OTHER THAN 4 WIRE, MULTI-
GROUNDED, USE SEPARATE GROUNDING
CONDUCTORS AND ELECTRODES FOR PRIMARY
AND SECONDARY SYSTEM DEVICE CONNECTIONS.
#4 600V INSULATED COPPER GROUNDING
CONDUCTOR REQUIRED ON PRIMARY SYSTEM
WHEN SEPARATE SYSTEMS ARE REQUIRED.
4.
K. MEARS
J. BARKLEY
M. LAPOINT
8'-0 MIN.
(FROM 24'-4"
TO 16'-4"
ABOVE GRADE)
18"
MAX
8'-0"
MIN.
10'-0"
MIN.
24"
MIN.
10'-0"
MIN.
2"
MIN.
| 60033559 |
| 60033560 |
| 60033561 |
| 60033562 |
| 60033563 |
| 60033564 |
| 60033565 |
| 60033566 |
| 60033567 |
| 60033568 |
| 60033569 |
| 60033570 |
| 60033571 |
| 60033572 |
| 60033573 |
| 60033574 |
| 60033575 |
| 60033576 |
| 60033577 |
| 60033578 |
| 60033579 |
| 60033580 |
| 60033581 |
| 60033582 |
| 60033583 |
| 60033584 |
| 60033585 |
| 60033586 |
| 60033587 |
File details come from the government source that posted it. Updated .