PWD Norfolk, Facilities Engineering and Acquisition Division Page 1 of 1

Design Revision 01 eProjects Work Order Number: 1599959

Construction Contract Number:

Building: B-30

Project Title: EOC Renovation

Date: July 01, 2020

Design Revision Purpose

1. To address PPI questions.

Drawing Revisions

The following drawings are revised as of July 1, 2020 and accompany this Design Revision:

NAVFAC Dwg. No. Title

Electrical

12,812,467 (EP601) POWER RISER, SCHEDULES, AND DETAILS

On NAVFAC Drawing No. 12,812,467 (EP601)

ADDED NOTE #6: Added note #6 which reads: “DEMOLISH EXISTING MDP. PRESERVE ALL EXISTING CIRCUITS FED FROM EXISTING 800A MDP TO BE REPLACED. PROVIDE NEW 800A RATED MDP. ENSURE NEW MDP HAS ADEQUATE SPACE FOR NEW 400A BREAKER FOR PANEL LD1 AND ALL EXISTING BRANCH CIRCUITS PRESERVED FROM DEMOLITION OF EXISTING MDP. RECONNECT ALL EXISTING CIRCUITS PRESERVED FROM

DEMOLITION TO NEW MDP.”

ADDED NOTE #6 TO POWER RISER DIAGRAM: Included annotation to MDP for note #6 on the Power Riser Diagram

Specification Revisions

DIVISION 01 – GENERAL REQUIREMENTS

SECTION 01 11 00 SUMMARY OF WORK

1.5 Government-Furnished Material and Equipment

ADD “GFE IDS Panel” and “CCTV Head End unit” to the Description column and “1” quantity of both to the quantity column.

150A 3P

150A 3P

125A 3P

150A 3P

125A 3P

125A 3P

125A 3P

125A 3P

250A 3P

400A

3P SP

AC

E

SP

AC

E

SP

AC

E

PNL

PB

PNL

PC

PNL

LA2

PNL

LA3

PNL

LB2

PNL

LB3

PNL

LC2

PNL

LC3

MDP PNL

LD1

800A 3P

TO 800A ATS MDPA 120/208V, 3PHASE, 4 WIRE, 800A, 50KAIC ON THIRD FLOOR

PNL

LD1A

AF-1APRIL 2015

GENERAL ARC FLASH WARNING LABEL

SKETCH DATE STYLE

NOTES:

1. PROVIDE SELF-ADHESIVE VINYL LABEL TO AFFIX TO ELECTRICAL EQUIPMENT TO WARN OF ARC

FLASH HAZARDS.

2. THE LABEL FORMAT AND TEXT SHALL BE IN ACCORDANCE WITH THE FIGURE.

3. THE LABEL SHALL BE LOCATED ON THE EQUIPMENT TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS

BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT.

4. THE SIZE OF THE LABEL SHALL BE MINIMUM:

EQUIPMENT TYPE HEIGHT WIDTH

INDOOR 2" 3"

OUTDOOR 3" 4.5"

5. A DOWNLOADABLE WINDOWS METAFILE IS AVAILABLE ON THE WHOLE BUILDING DESIGN GUIDE

WEBSITE (WWW.WDBG.ORG) FOR USE IN A LABEL MAKING MACHINE.

A. THE FILE IS LOCATED ON THE "NAVFAC CADD DETAILS" PAGE. TO NAVIGATE TO THIS LOCATION, FOLLOW: HOME > DOCUMENTS & REFERENCES > CCB > CADD LIBRARY > NAVFAC CADD

RESOURCES > NAVFAC CADD DETAILS.

B. ALTERNATIVELY, TYPE IN THE FOLLOWING ADDRESS IN INTERNET EXPLORER:

HTTP://WWW.WBDG.ORG/CCB/BROWSE_CAT.PHP?C=23

WIDTH

HEIGHT

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G C

O M

M

AN

D

DRAWFORM REVISION: 7 FEBRUARY 2019

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

M

ID

-A

TL

A N

TI

C

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

UNCLASSIFIED

UNCLASSIFIED

UN

CL

AS

S I

FI

ED

PW

D

NO

RF

OL

K

EP601

B U

IL

D

IN

G

B -3

PO

W

ER

R

IS

ER

, S

CH

ED

UL

ES

, A

ND

D

ET

AI

LS

KJF

12,812,467

MPH MPH

3/13/2020

GENE LAMBERT, EOC

EO

C

RE

NO

VA

TI

O N

LACIE A. BEEMER, R.A.

1599959

NA

VA

L S

TA

TI

O N

NO

RF

OL

K , V

A

NA

V A L S

TA

TI

ON

N

OR

FO

R K

SEAN SEENEY, P.E.

NOT TO SCALE

POWER RISER DIAGRAM

TOTAL CONNECTED AMPS: A: 302.4 B: 298.2 C: 274.9

41 30 A 56 A 42 39 46 A 56 A 40

LD1A 1-1/2" 1 100

26 A 56 A

60 6 1" AHU-3

35 56 A 53 A 36 33 56 A 53 A 34

AHU-1 1" 6 60

56 A 53 A

60 6 1" AHU-2

29 LIGHTING 3/4" 12 20 8 A 9 A 20 12 3/4" LIGHTING 30

27 28

25 ISAC WORKSTATION 1/2" 12 20 10 A 0 A 20 -- -- SPARE 26

23 ISAC WORKSTATION 1/2" 12 20 8 A 0 A 20 -- -- SPARE 24

21 ISAC WORKSTATION 1/2" 12 20 10 A 0 A 20 -- -- SPARE 22

19 GIANT VOICE 1/2" 12 20 10 A 0 A 20 -- -- SPARE 20

17 PRINTER 1/2" 12 20 10 A 0 A 20 -- -- SPARE 18

15 EOC REC. 1/2" 12 20 12 A 10 A 20 12 1/2" SIPR RACK 16

13 EMO OFFICE REC. 1/2" 12 20 18 A 19 A 20 12 1/2" SIPR. OFFICE REC. & LTS 14

11 EOC WORKSTATIONS 1/2" 12 20 15 A 5 A 20 12 1/2" ITO RADIO CHARGER 12

9 EOC WORKSTATIONS 1/2" 12 20 15 A 18 A 20 12 1/2" ITO REC. 10

7 EOC WORKSTATIONS 1/2" 12 20 15 A 12 A 8

5 EOC WORKSTATIONS 1/2" 12 20 15 A 12 A

30 10 1" NMCI RACK

3 EOC TELEVISIONS 1/2" 12 20 9 A 10 A 20 12 1/2" SPECIAL SYSTEM REC. 4

1 EOC MANAGER REC. 1/2" 12 20 16 A 10 A 20 12 1/2" TELECOM REC. 2

CKT

NO. LOAD DESCRIPTION

COND

SIZE

WIRE

SIZE

BKR

TRIP A B C A B C BKR

TRIP

WIRE

SIZE

COND

SIZE LOAD DESCRIPTION

CKT

NO.

AMP BUS 400 A MCB 120/208 Wye VOLTS 3PH, 4W, SN, 60HZ MIN. KAIC SURFACE

PANEL LD1 SCHEDULE

GENERAL NOTES

NOTES#

1 PROVIDE 400A RATED BREAKER IN MAIN DISTRIBUTION PANELBOARD.

2 PROVIDE FOUR 400KCMIL THHN/THWN COPPER CONDUCTORS AND ONE

#4 AWG COPPER GROUND IN 3" EMT CONDUIT FROM NEW 400A RATED

PANELBOARD TO EXISTING MAIN DISTRIBUTION PANELBOARD LOCATED

ON THIRD FLOOR. ASSUME APPROX. 250' OF CONDUIT BETWEEN MDP

AND PROVIDED PANELBOARD.

3 PROVIDE 400A RATED MAIN CIRCUIT BREAKER 208/120V, 3 PHASE, 4

WIRE FLUSH MOUNTED NEMA 1 PANELBOARD. SEE SHEET EP101 FOR

LOCATION.

4 PROVIDE FOUR #1AWG THHN/THWN COPPER CONDUCTORS AND ONE #8

AWG COPPER GROUND IN 1-1/2" EMT CONDUIT FROM 400A RATED

PANELBOARD LD1 TO LD1A.

5 PROVIDE 100A RATED MAIN LUG ONLY, 30 SPACE, 208/120V, 3 PHASE, 4

WIRE FLUSH MOUNTED NEMA 1 PANELBOARD. SEE SHEET EP101 FOR

LOCATION.

6 DEMOLISH EXISTING MDP. PRESERVE ALL EXISTING CIRCUITS FED

FROM EXISTING 800A MDP TO BE REPLACED. PROVIDE NEW 800A

RATED MDP. ENSURE NEW MDP HAS ADEQUATE SPACE FOR NEW 400A

BREAKER FOR PANEL LD1 AND ALL EXISTING BRANCH CIRCUITS

PRESERVED FROM DEMOLITION OF EXISTING MDP. RECONNECT ALL

EXISTING CIRCUITS PRESERVED FROM DEMOLITION TO NEW MDP.

3 4

TOTAL CONNECTED AMPS: A: 26.5 B: 47.1 C: 31.1

29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16

13 SPARE -- -- 20 0 A 0 A 20 -- -- SPARE 14

11 SPARE -- -- 20 0 A 0 A 20 -- -- SPARE 12

9 CONF. AV AND... 1/2" 12 20 10 A 20 A 30 10 1/2" VENDING MACHINES 10

7 CONF REC. 1/2" 12 20 8 A 3 A 20 12 1/2" BREAK ROOM REC. 8

5 BREAK RM, BUNK & HALL... 1/2" 12 20 11 A 20 A 30 10 3/4" COFFEE MAKER 6

3 STORAGE RECEPT. 1/2" 12 20 5 A 12 A 20 12 1/2" FRIDGE 4

1 TRAINING REC. 1/2" 12 20 12 A 4 A 20 12 1/2" ICE MACHINE 2

CKT

NO. LOAD DESCRIPTION

COND

SIZE

WIRE

SIZE

BKR

TRIP A B C A B C BKR

TRIP

WIRE

SIZE

COND

SIZE LOAD DESCRIPTION

CKT

NO.

AMP BUS 100 A MLO 120/208 Wye VOLTS 3PH, 4W, SN, 60HZ MIN. KAIC SURFACE

PANEL LD1A SCHEDULE

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

De sig n R ev isi on

-0

1-

MP

H

2018_1599959_EP601.pdf
Sheets
EP601 - POWER RISER, SCHEDULES, AND DETAILS

2020-07-01T14:38:07-0400

2020-07-01T14:43:05-0400

2020-07-01T14:43:25-0400

2020-07-01T14:46:08-0400

File details come from the government source that posted it. Updated .