1599959 _Design Revision A.pdf
PDF 301 KB Posted
- Solicitation number
- N40085-20-R-8011
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N40085-20-R-8011 Amendment 0001.pdf | ||
| ATTACHMENT D - Pre-Proposal_Inquiry_Form.xls | XLS spreadsheet | |
| N4008520R8011 General Requirements.pdf | ||
| ATTACHMENT C - VA20200160.pdf | ||
| ATTACHMENT A - 1599959_B-30 EOC_DWGS.pdf | ||
| ATTACHMENT B - 1599959_B-30 EOC_SPECS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PWD Norfolk, Facilities Engineering and Acquisition Division Page 1 of 1
Design Revision 01 eProjects Work Order Number: 1599959
Construction Contract Number:
Building: B-30
Project Title: EOC Renovation
Date: July 01, 2020
Design Revision Purpose
1. To address PPI questions.
Drawing Revisions
The following drawings are revised as of July 1, 2020 and accompany this Design Revision:
NAVFAC Dwg. No. Title
Electrical
12,812,467 (EP601) POWER RISER, SCHEDULES, AND DETAILS
On NAVFAC Drawing No. 12,812,467 (EP601)
ADDED NOTE #6: Added note #6 which reads: “DEMOLISH EXISTING MDP. PRESERVE ALL EXISTING CIRCUITS FED FROM EXISTING 800A MDP TO BE REPLACED. PROVIDE NEW 800A RATED MDP. ENSURE NEW MDP HAS ADEQUATE SPACE FOR NEW 400A BREAKER FOR PANEL LD1 AND ALL EXISTING BRANCH CIRCUITS PRESERVED FROM DEMOLITION OF EXISTING MDP. RECONNECT ALL EXISTING CIRCUITS PRESERVED FROM
DEMOLITION TO NEW MDP.”
ADDED NOTE #6 TO POWER RISER DIAGRAM: Included annotation to MDP for note #6 on the Power Riser Diagram
Specification Revisions
DIVISION 01 – GENERAL REQUIREMENTS
SECTION 01 11 00 SUMMARY OF WORK
1.5 Government-Furnished Material and Equipment
ADD “GFE IDS Panel” and “CCTV Head End unit” to the Description column and “1” quantity of both to the quantity column.
150A 3P
150A 3P
125A 3P
150A 3P
125A 3P
125A 3P
125A 3P
125A 3P
250A 3P
400A
3P SP
AC
E
SP
AC
E
SP
AC
E
PNL
PB
PNL
PC
PNL
LA2
PNL
LA3
PNL
LB2
PNL
LB3
PNL
LC2
PNL
LC3
MDP PNL
LD1
800A 3P
TO 800A ATS MDPA 120/208V, 3PHASE, 4 WIRE, 800A, 50KAIC ON THIRD FLOOR
PNL
LD1A
AF-1APRIL 2015
GENERAL ARC FLASH WARNING LABEL
SKETCH DATE STYLE
NOTES:
1. PROVIDE SELF-ADHESIVE VINYL LABEL TO AFFIX TO ELECTRICAL EQUIPMENT TO WARN OF ARC
FLASH HAZARDS.
2. THE LABEL FORMAT AND TEXT SHALL BE IN ACCORDANCE WITH THE FIGURE.
3. THE LABEL SHALL BE LOCATED ON THE EQUIPMENT TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS
BEFORE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE OF THE EQUIPMENT.
4. THE SIZE OF THE LABEL SHALL BE MINIMUM:
EQUIPMENT TYPE HEIGHT WIDTH
INDOOR 2" 3"
OUTDOOR 3" 4.5"
5. A DOWNLOADABLE WINDOWS METAFILE IS AVAILABLE ON THE WHOLE BUILDING DESIGN GUIDE
WEBSITE (WWW.WDBG.ORG) FOR USE IN A LABEL MAKING MACHINE.
A. THE FILE IS LOCATED ON THE "NAVFAC CADD DETAILS" PAGE. TO NAVIGATE TO THIS LOCATION, FOLLOW: HOME > DOCUMENTS & REFERENCES > CCB > CADD LIBRARY > NAVFAC CADD
RESOURCES > NAVFAC CADD DETAILS.
B. ALTERNATIVELY, TYPE IN THE FOLLOWING ADDRESS IN INTERNET EXPLORER:
HTTP://WWW.WBDG.ORG/CCB/BROWSE_CAT.PHP?C=23
WIDTH
HEIGHT
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D
M
ID
-A
TL
A N
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
UNCLASSIFIED
UNCLASSIFIED
UN
CL
AS
S I
FI
ED
PW
D
NO
RF
OL
K
EP601
B U
IL
D
IN
G
B -3
PO
W
ER
R
IS
ER
, S
CH
ED
UL
ES
, A
ND
D
ET
AI
LS
KJF
12,812,467
MPH MPH
3/13/2020
GENE LAMBERT, EOC
EO
C
RE
NO
VA
TI
O N
LACIE A. BEEMER, R.A.
1599959
NA
VA
L S
TA
TI
O N
NO
RF
OL
K , V
A
NA
V A L S
TA
TI
ON
N
OR
FO
R K
SEAN SEENEY, P.E.
NOT TO SCALE
POWER RISER DIAGRAM
TOTAL CONNECTED AMPS: A: 302.4 B: 298.2 C: 274.9
41 30 A 56 A 42 39 46 A 56 A 40
LD1A 1-1/2" 1 100
26 A 56 A
60 6 1" AHU-3
35 56 A 53 A 36 33 56 A 53 A 34
AHU-1 1" 6 60
56 A 53 A
60 6 1" AHU-2
29 LIGHTING 3/4" 12 20 8 A 9 A 20 12 3/4" LIGHTING 30
27 28
25 ISAC WORKSTATION 1/2" 12 20 10 A 0 A 20 -- -- SPARE 26
23 ISAC WORKSTATION 1/2" 12 20 8 A 0 A 20 -- -- SPARE 24
21 ISAC WORKSTATION 1/2" 12 20 10 A 0 A 20 -- -- SPARE 22
19 GIANT VOICE 1/2" 12 20 10 A 0 A 20 -- -- SPARE 20
17 PRINTER 1/2" 12 20 10 A 0 A 20 -- -- SPARE 18
15 EOC REC. 1/2" 12 20 12 A 10 A 20 12 1/2" SIPR RACK 16
13 EMO OFFICE REC. 1/2" 12 20 18 A 19 A 20 12 1/2" SIPR. OFFICE REC. & LTS 14
11 EOC WORKSTATIONS 1/2" 12 20 15 A 5 A 20 12 1/2" ITO RADIO CHARGER 12
9 EOC WORKSTATIONS 1/2" 12 20 15 A 18 A 20 12 1/2" ITO REC. 10
7 EOC WORKSTATIONS 1/2" 12 20 15 A 12 A 8
5 EOC WORKSTATIONS 1/2" 12 20 15 A 12 A
30 10 1" NMCI RACK
3 EOC TELEVISIONS 1/2" 12 20 9 A 10 A 20 12 1/2" SPECIAL SYSTEM REC. 4
1 EOC MANAGER REC. 1/2" 12 20 16 A 10 A 20 12 1/2" TELECOM REC. 2
CKT
NO. LOAD DESCRIPTION
COND
SIZE
WIRE
SIZE
BKR
TRIP A B C A B C BKR
TRIP
WIRE
SIZE
COND
SIZE LOAD DESCRIPTION
CKT
NO.
AMP BUS 400 A MCB 120/208 Wye VOLTS 3PH, 4W, SN, 60HZ MIN. KAIC SURFACE
PANEL LD1 SCHEDULE
GENERAL NOTES
NOTES#
1 PROVIDE 400A RATED BREAKER IN MAIN DISTRIBUTION PANELBOARD.
2 PROVIDE FOUR 400KCMIL THHN/THWN COPPER CONDUCTORS AND ONE
#4 AWG COPPER GROUND IN 3" EMT CONDUIT FROM NEW 400A RATED
PANELBOARD TO EXISTING MAIN DISTRIBUTION PANELBOARD LOCATED
ON THIRD FLOOR. ASSUME APPROX. 250' OF CONDUIT BETWEEN MDP
AND PROVIDED PANELBOARD.
3 PROVIDE 400A RATED MAIN CIRCUIT BREAKER 208/120V, 3 PHASE, 4
WIRE FLUSH MOUNTED NEMA 1 PANELBOARD. SEE SHEET EP101 FOR
LOCATION.
4 PROVIDE FOUR #1AWG THHN/THWN COPPER CONDUCTORS AND ONE #8
AWG COPPER GROUND IN 1-1/2" EMT CONDUIT FROM 400A RATED
PANELBOARD LD1 TO LD1A.
5 PROVIDE 100A RATED MAIN LUG ONLY, 30 SPACE, 208/120V, 3 PHASE, 4
WIRE FLUSH MOUNTED NEMA 1 PANELBOARD. SEE SHEET EP101 FOR
LOCATION.
6 DEMOLISH EXISTING MDP. PRESERVE ALL EXISTING CIRCUITS FED
FROM EXISTING 800A MDP TO BE REPLACED. PROVIDE NEW 800A
RATED MDP. ENSURE NEW MDP HAS ADEQUATE SPACE FOR NEW 400A
BREAKER FOR PANEL LD1 AND ALL EXISTING BRANCH CIRCUITS
PRESERVED FROM DEMOLITION OF EXISTING MDP. RECONNECT ALL
EXISTING CIRCUITS PRESERVED FROM DEMOLITION TO NEW MDP.
3 4
TOTAL CONNECTED AMPS: A: 26.5 B: 47.1 C: 31.1
29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16
13 SPARE -- -- 20 0 A 0 A 20 -- -- SPARE 14
11 SPARE -- -- 20 0 A 0 A 20 -- -- SPARE 12
9 CONF. AV AND... 1/2" 12 20 10 A 20 A 30 10 1/2" VENDING MACHINES 10
7 CONF REC. 1/2" 12 20 8 A 3 A 20 12 1/2" BREAK ROOM REC. 8
5 BREAK RM, BUNK & HALL... 1/2" 12 20 11 A 20 A 30 10 3/4" COFFEE MAKER 6
3 STORAGE RECEPT. 1/2" 12 20 5 A 12 A 20 12 1/2" FRIDGE 4
1 TRAINING REC. 1/2" 12 20 12 A 4 A 20 12 1/2" ICE MACHINE 2
CKT
NO. LOAD DESCRIPTION
COND
SIZE
WIRE
SIZE
BKR
TRIP A B C A B C BKR
TRIP
WIRE
SIZE
COND
SIZE LOAD DESCRIPTION
CKT
NO.
AMP BUS 100 A MLO 120/208 Wye VOLTS 3PH, 4W, SN, 60HZ MIN. KAIC SURFACE
PANEL LD1A SCHEDULE
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
De sig n R ev isi on
-0
1-
MP
H
| 2018_1599959_EP601.pdf |
| Sheets |
| EP601 - POWER RISER, SCHEDULES, AND DETAILS |
2020-07-01T14:38:07-0400
2020-07-01T14:43:05-0400
2020-07-01T14:43:25-0400
2020-07-01T14:46:08-0400
File details come from the government source that posted it. Updated .