This is a continuation sheet for federal contract N39040Q5333V266 detailing the manufacture of three types of steel disposal containers for the Philadelphia Naval Shipyard (PNSY). The contract requires 2 Small Shear Block Disposal Containers (RF-2203), 16 Large Shear Block Disposal Containers (RF-2202), and 1 Lead Screw Disposal Container (RF-2100), all manufactured from ASTM A36-19 steel according to specified drawing numbers and revisions. The containers must include safety hoist rings and lifting lugs that require load/proof testing.

The contractor must perform visual testing per AWS D1.1/D1.1M:2020, magnetic particle testing per NAVSEA Technical Publication T9074-AS-GIB-010/271 REV 1 and MIL-STD-2035A, and load/proof testing on all lifting components. PNSY will conduct government inspections at approximately the halfway point of construction, during magnetic particle testing, and upon completion. The contractor must coordinate inspection scheduling with PNSY and provide extensive data requirements via DD-1423 exhibits, including certificates of compliance, pre- and post-test certifications for visual and magnetic particle testing, load/proof test certifications, and material safety data sheets. All items must be permanently marked after successful load/proof testing per drawing specifications.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQ DOC NO. - 5333V266, 5333V267, 5340V284 ATTACHMENT ___1___

CONTINUATION SHEET CONTRACT NO. - N39040Q5333V266

NAME OF OFFER OR/CONTRACTOR

1 SMALL SHEAR BLOCK DISPOSAL CONTAINER 2 EA

2 LARGE SHEAR BLOCK DISPOSAL CONTAINER 16 EA

3 LEAD SCREW DISPOSAL CONTAINER 1 EA

C. DESCRIPTION/SPECIFICATIONS

C.1. ALL DISPOSAL CONTAINERS STEEL PER ASTM–A36-19:

C.1.1. SMALL SHEAR BLOCK DISPOSAL CONTAINER (RF-2203):

C.1.1.1. QTY (2) COMPLETE UNITS

C.1.1.2. MANUFACTURE IN ACCORDANCE WITH PNS

2370A0000389 REV A. DRAWING IS ATTACHED.

C.1.2. LARGE SHEAR BLOCK DISPOSAL CONTAINER (RF-2202):

C.1.2.2. QTY (16) COMPLETE UNITS

C.1.2.3. MANUFACTURE IN ACCORDANCE WITH PNS

2370A0000388 REV A. DRAWING IS ATTACHED.

C.1.3. LEAD SCREW DISPOSAL CONTAINERS (RF-2100):

C.1.3.1. QTY (1) COMPLETE UNIT

C.1.3.2. MANUFACTURE IN ACCORDANCE WITH PNS

2370A0000137 REV C. DRAWING IS ATTACHED.

C.2 PNSY PLANS TO INSPECT THE CONTAINERS AT AN APPROXIMATE

HALF-WAY POINT OF CONSTRUCTION, DURING THE MAGNETIC

PARTICLE TESTING AND AT COMPLETION OF CONSTRUCTION.

ITEM # SUPPLIES/SERVICES QTY U/I

C.2.1 CONTRACTOR SHALL NOTIFY PNSY WITH PROJECTED WORK

SCHEDULE. HALFWAY POINT OF CONSTRUCTION SHALL BE

DETERMINED BY THE CONTRACTOR AND PNSY AFTER AWARD OF

CONTRACT.

C.3 PERFORM A VISUAL TEST ON ALL UNITS PER AWS D1.1/D.1.1M:2020;

STRUCTURAL WELDING CODE – STEEL; 24TH EDITION, APPROVED 9

DECEMBER 2019.

C.4 PERFORM MAGNETIC PARTICLE TESTING ON ALL UNITS PER

NAVSEA TECHNICAL PUBLICATION T9074-AS-GIB-010/271 REV 1;

REQUIREMENTS FOR NONDESTUCTIVE TESTING METHODS AND MIL-

STD-2035A; NONDESTRUCTIVE TESTING ACCEPTANCE CRITERIA.

C.5 PERFORM LOAD/PROOF TEST ON SAFETY HOIST RING AND LIFTING

LUGS ON ALL UNITS PER THE INSTRUCTIONS AND REQUIREMENTS

OF THE STATEMENT OF TESTS AND DRAWING. BOTH ARE

ATTACHED.

C.6 GOVERNMENT INSPECTION IS REQUIRED DURING MANUFACTURE

AND PRIORTO SHIPMENT FROM THIS FACILITY. UPON RECEIPT OF

THIS ORDER, PROMPLTLY NOTIFY THE REPRESENTATIVE OF THE

GOVERNMENT OFFICE WHO NORMALLY SERVES YOUR FACILITY SO

THAT APPROPRIATE PLANNING FOR GOVERNMENT INSPECTION CAN

BE ACCOMPLISHED. IN THE EVENT A REPRESENTATIVE OF THE

GOVERNMENT OFFICE CANNOT BE LOCATED, THE PURCHASING

AGENT SHOULD BE NOTIFIED PROMPLTLY.

C.7 DATA REQUIREMENTS PER EXHIBIT A (DD-1423) & ATTCHMENT #1,

FOR SAFETY HOIST RING

C.7.1 CERTIFICATE OF COMPLIANCE; EXHIBIT A SEQUENCE A002AA,

A004AA, AND A006AA.

C.7.2 BEFORE VISUAL TEST CERTIFICATION, EXHIBIT A SEQUENCE

A002AB, A004AB, AND A006AB.

C.7.3 AFTER VISUAL TEST CERTIFICATION, EXHIBIT A SEQUENCE

A002AC, A004AC, AND A006AC.

C.7.4 BEFORE MAGNETIC PARTICLE TEST CERIFICATION, EXHIBIT A

SEQUENCE A002AD, A004AD, AND A006AD.

C.7.5 AFTER MAGNETIC PARTICLE TEST CERIFICATION, EXHIBIT A

SEQUENCE A002AE, A004AE, AND A006AE.

C.7.6 LOAD/PROOF TEST CERIFICATION, EXHIBIT A SEQUENCE

A002AF, A004AF, AND A006AF.

C.8 DATA REQUIREMENTS PER EXHIBIT A (DD-1423) & ATTCHEMT #1,

FOR LIFTING LUGS.

C.8.1 CERTIFICATE OF COMPLIANCE; EXHIBIT A SEQUENCE A002AG,

A004AG, AND A006AG.

C.8.2 BEFORE VISUAL TEST CERTIFICATION, EXHIBIT A SEQUENCE

A002AH, A004AH, AND A006AH.

C.8.3 AFTER VISUAL TEST CERTIFICATION, EXHIBIT A SEQUENCE

A002AI, A004AI, AND A006AI.

C.8.4 BEFORE MAGNETIC PARTICLE TEST CERTIFICATION, EXHIBIT

A SEQUENCE A002AJ, A004AJ, AND A006AJ.

C.8.5 AFTER MAGNETIC PARTICLE TEST CERTIFICATION, EXHIBIT A

SEQUENCE A002AK, A004AK, AND A006AK.

C.8.6 LOAD/PROOF TEST CERIFICATION, EXHIBIT A SEQUENCE

A002AL, A004AL, AND A006AL.

C.9 MATERIAL SAFETY DATA SHEETS, EXHIBIT A SEQUENCE A007.

D. PACKING/PACKAGING/MARKINGS:

D.1 FOLLOWING SATISFACTORY COMPLETION OF LOAD/PROOF

TEST, PERMANENTLY MARK ITEMS AS REQUIRED PER DRAWING

AND STATEMENT OF REQUIRED TESTS.