CLIN_0002_Attachments.pdf

PDF 1 MB Posted

Attached to
Shielding Federal contract opportunity
Solicitation number
N3904019Q0086
Issued by
Department of the Navy Naval Sea Systems Command

About this file

ALL ATTACHMENTS HAVE BEEN REPLACED

View the file

Other files for this federal contract opportunity

Other files attached to Shielding, newest first.
File Type Posted
CLIN_0003_Attachments.pdf PDF
CLIN_0004_Attachments.pdf PDF
CLIN_0001_Attachments.pdf PDF
Urgency_Statement_Redacted.pdf PDF
CLIN_0005_Attachments.pdf PDF
CLIN_0002_Attachments.pdf PDF
N3904019Q0086_RFQ.pdf PDF
CLIN_0001_Attachments.pdf PDF
CLIN_0003_Attachments.pdf PDF
CLIN_0005_Attachments.pdf PDF
CLIN_0004_Attachments.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQ DOC NO. - 8313V044 REV 1 ATTACHMENT AMD

CONTINUATION SHEET CONTRACT NO. - PAGE

OF

NAME OF OFFER OR/CONTRACTOR

ITEM # SUPPLIES/SERVICES QTY U/I

XY SHIELD 2 EACH

C. DESCRIPTION/SPECIFICATIONS.

C.1 PIECE 2 OF FINAL CLOSURE COVER, STAINLESS STEEL, XY SHIELD

(RF-6600, LIN 0001) MANUFACTURED IAW PNS 2370B0000095 REV A.

SEE ATTACHMETS FOR ADDITIONAL REQUIREMENTS AND

INFORMATION.

C.2 PNSY PLANS TO INSPECT THE COVER AT AN APPROXIMATE HALF

WAY POINT OF CONSTRUCTION.

C.2.1 CONTRACTOR SHALL NOTIFY PNSY WITH PROJECTED

WORK SCHEDULE. HALFWAY POINT OF CONSTRUCTION SHALL

BE DETERMINED BY THE CONTRACTOR AND PNSY AFTER

AWARD OF CONTRACT.

C.3 PERFORM A TORQUE BASED LOAD TEST OF THE SPECIFIED

THREADED HOLES PER THE INSTRUCTIONS ABD REQUIREMENTS

OF THE ATTACHED DRAWINGS.

C.4 PERFORM LIQUID PENETRANT (PT) INSPECTIONS PER NAVSEA

TECHNICAL PUBLICATION T9074-AS-GIB-010/271 2014 EDITON, 11

SEPTEMBER 2018.

C.4.1 USE MIL-STD-2035A 15 MAY 1995, FOR ALL NON-

DESTUCTIVE INSPECTION ACCEPTANCE CRITERIA.

C.4.2 VISUAL INSPECTIONS (5X MINIMUM) MAYBE PERFORMED

IN CASES WHERE LIQUID PENETRANT INSPECTIONS ARE

IMPRACTICAL.

C.6 NAVSEA HQ C-2-0023 MERCURY CONTROL

C.7 DATA REQUIREMENTS PER EXHIBIT A (DD-1423) & ATTACH #1.

C.7.1 CERTIFICATE OF COMPLIANCE; EXHIBIT A SEQUENCE A001.

C.7.2 LIQUID PENETRANT TEST CERTIFICATION, EXHIBIT A

SEQUENCE A002.

C.7.3 LOAD TEST CERIFICATION, EXHIBIT A SEQUENCE A003.

C.7.4 VISUAL TEST CERTIFICATION (IF APPLICABLE), EXHIBIT A

SEQUENCE A004.

D. PRESERVATION/PACKAGING/PACKING.

D.1 D4 PREPARATION FOR DELIVERY (COMMERCIALLY PACKAGED).

E. INSPECTION AND ACCEPTANCE.

E.1 FAR 52.246-2 INSPECTION OF SUPPLIES. FIXED PRICE

E.2 FAR 52.212-4 CONTRACT TERMS & CONDITONS (COMMERCIAL)

E.3 NAVSEA HQ E-1-0003 INSPECTION & ACCEPTANCE OF F.O.B.

SESTINATION DELIVERIES.

CONTRACT

PRINTED 12/13/2018 PAGE

EXHIBIT A

(ADP DD FORM 1423 (MECHANIZED EQUIVALENT) PER DAR CLAUSE 16-815)

CONTRACT DATA REQUIREMENTS LIST

SYSTEM/ITEM XY SHIELD, FINAL

CLOSURE

CATEGORY

ITEM NO 001 CONTRACTOR

01 SEQ NO A001

02 DATA DESC CERTIFICATE OF COMPLIANCE

03 SUBTITLE

04 DID NUMBER PER ATTACHMENT 1 TO EXHIBIT A

05 CONTRACT

REF

PARA. C.7.1

06 TECH OFFICE 2370.1

07 DD 250 REQ DD

08 APP CODE

09 IAC INPUT

10 FREQUENCY O-TIME

11 AS OF DATE

12 DATE 1ST

SUBM

WITH MATERIAL

13 DATE SUB

SUBM

14 DISTRIBUTION 410/2370 1/ 0 VIA MAIL (N0 DD 250 REQD)

15 TOTAL 1

16 REMARKS

SEQ. NO. A001

PREPARED BY DATE

APPROVED BY DATE

DD FORM 1423

EXHIBIT A

(ADP DD FORM 1423 (MECHANIZED EQUIVALENT) PER DAR CLAUSE 16-815)

CONTRACT DATA REQUIREMENTS LIST

SYSTEM/ITEM XY SHIELD, FINAL

CLOSURE

CATEGORY

ITEM NO 002 CONTRACTOR

01 SEQ NO A002

02 DATA DESC LIQUID PENETRANT CERTIFICATION

03 SUBTITLE

04 DID NUMBER PER ATTACHMENT 1 TO EXHIBIT A

05 CONTRACT REF PARA. C.7.2

06 TECH OFFICE 2370.1

07 DD 250 REQ DD

08 APP CODE

09 IAC INPUT

10 FREQUENCY O-TIME

11 AS OF DATE

12 DATE 1ST SUBM WITH MATERIAL

13 DATE SUB SUBM

14 DISTRIBUTION 410 1/ 0 VIA MAIL (N0 DD 250 REQD)

15 TOTAL 1

16 REMARKS

SEQ. NO. A002

PREPARED BY DATE

ATTACHMENT 1 TO EXHIBIT A (DD FORM 1423)

SYSTEM/ITEM XY SHIELD, FINAL

CLOSURE

CATEGORY

ITEM NO 003 CONTRACTOR

01 SEQ NO A003

02 DATA DESC LOAD TEST CERTIFICATION

03 SUBTITLE

04 DID NUMBER PER ATTACHMENT 1 TO EXHIBIT A

05 CONTRACT REF PARA. C.7.3

06 TECH OFFICE 2370.1

07 DD 250 REQ DD

08 APP CODE

09 IAC INPUT

10 FREQUENCY O-TIME

11 AS OF DATE

12 DATE 1ST SUBM WITH MATERIAL

13 DATE SUB SUBM

14 DISTRIBUTION 410 1/ 0 VIA MAIL (N0 DD 250 REQD)

15 TOTAL 1

16 REMARKS

SEQ. NO. A003

PREPARED BY DATE

SYSTEM/ITEM XY SHEILD, FINAL

CLOSURE

CATEGORY

ITEM NO 004 CONTRACTOR

01 SEQ NO A004

02 DATA DESC VISUAL TEST CERTIFICATION (IF APPLICABLE)

03 SUBTITLE

04 DID NUMBER PER ATTACHMENT 1 TO EXHIBIT A

05 CONTRACT REF PARA. C.7.4

06 TECH OFFICE 2370.1

07 DD 250 REQ DD

08 APP CODE

09 IAC INPUT

10 FREQUENCY O-TIME

11 AS OF DATE

12 DATE 1ST SUBM WITH MATERIAL

13 DATE SUB SUBM

14 DISTRIBUTION 410 1/ 0 VIA MAIL (N0 DD 250 REQD)

15 TOTAL 1

16 REMARKS

SEQ. NO. A004

PREPARED BY DATE

CONTRACT/SOLICITATION __________________________

ITEM _____________ (DATA FOR ITEM __________________________)

REQUIRED CERTIFICATION

A. CERTIFICATION SHALL BE SUPPLIED WITH EACH SHIPMENT OF MATERIAL.

CERTIFICATION (CERTIFICATE OF COMPLIANCE) SHALL BE SUPPLIED AS OUTLINED IN

PARAGRAPH B. THE VENDOR IS LIABLE FOR CONDUCTING ALL TESTS, ANALYSES,

INSPECTIONS, AND EXAMINATIONS, ETC., AS SPECIFIED BY THE CONTRACT AND

SPECIFICATIONS WHETHER CERTIFICATIONS ARE REQUIRED OR NOT.

CERTIFICATE OF COMPLIANCE (PROVIDE THE FOLLOWING VERBATIM STATEMENT OR

COMPLETE THE OPTIONAL FORM AT THE END OF THIS PART):

"I ATTEST ALL ITEMS FURNISHED ON THIS CONTRACT ARE IN FULL COMPLIANCE WITH

ALL CONTRACT REQUIREMENTS. THE INSPECTION AND TEST REPORTS PROVIDED

REPRESENT THE ACTUAL ATTRIBUTES OF THE ITEMS FURISHED ON THIS CONTRACT AND

INDICATE FULL COMPLIANCE WITH ALL APPLICABLE SPECIFICATION AND CONTRACT

REQUIREMENTS.”

B. CERTIFICATION SHALL BE SUPPLIED PER THE FOLLOWING INSTRUCTIONS:

1. THE CERTIFICATION OF COMPLIANCE SHALL CONTAIN THE SIGNATURE AND TITLE OF

THE VENDOR OFFICIAL DESIGNATED RESPONSIBLE FOR QUALITY ASSURANCE.

2. THE MATERIAL IDENTIFICATION (E.G. LOT, BATCH, PART #, ETC.) SHALL BE INCLUDED

ON THE CERTIFICATE OF COMPLIANCE AND ASSOCIATED TEST CERTIFICATIONS.

CERTIFICATE OF COMPLIANCE

COMPANY NAME

MATERIAL IDENTIFICATION (COMPLETE APPLICABLE ITEMS)

CONTRACT NO. -___________________ ORDER NO. _________________

ITEM NO. _______________

LOCAL STOCK NUMBER: ______________________

MANUFACTURER'S PART NUMBER ______________

I ATTEST ALL ITEMS FURNISHED ON THIS CONTRACT ARE IN FULL COMPLIANCE WITH ALL

CONTRACT REQUIREMENTS. THE INSPECTION AND TEST REPORTS PROVIDED REPRESENT

THE ACTUAL ATTRIBUTES OF THE ITEMS FURISHED ON THIS CONTRACT AND INDICATE

FULL COMPLIANCE WITH ALL APPLICABLE SPECIFICATION AND CONTRACT

REQUIREMENTS.

SIGNATURE _______________________________ DATE ________

QUALITY ASSURANCE OFFICIAL

4 3

1. MANUFACTURING REQUIREMENTS

1.1. WHERE MIL-SPECS, STANDARDS, TECHNICAL PUBLICATIONS AND/OR REFERENCE

DRAWINGS ARE NOTED, THE LATEST REVISION SHALL BE IN EFFECT UNLESS OTHERWISE

SPECIFIED.

2. WELDING & NON-DESTRUCTIVE TESTING {NOT) REQUIREMENTS

2.1. NONE.

3. LOAD TEST & NON-DESTRUCTIVE TESTING {NOT) REQUIREMENTS c I 3.1. PERFORM A TORQUE BASED LOAD TEST OF THE SPECIFIED THREADED HOLES.

3.1.1. SEE DWG 5D13993 (CAGE 94259) FOR CERTIFICATION PROCEDURES.

B

A

3.2. PERFORM NON-DESTRUCTIVE TESTING ON EACH OF THE SPECIFIED THREADED HOLES

AFTER THE TORQUE BASED LOAD TEST.

3.2.1. PERFORM LIQUID PENETRANT (PT) INSPECTIONS PER NAVSEA TECHNICAL

PUBLICATION T9074-AS-GIB-010/271 .

3.2.2. VISUAL INSPECTIONS (5X MINIMUM) MAY BE PERFORMED IN CASES WHERE LIQUID

PENETRANT INSPECTIONS ARE IMPRACTICAL.

3.2.3. USE MIL-STD-2035 FOR ALL NON-DESTRUCTIVE INSPECTION ACCEPTANCE CRITERIA.

3.3. CHECK THE THREADS OF EACH OF THE SPECIFIED THREADED HOLES, USING A GO/NO-GO

GAUGE, AFTER THE TORQUE BASED LOAD TEST.

3.4. THE WORKING LOAD LIMIT (WLL) OF EACH SPECIFIED THREADED HOLE IS 2500 LB.

3.5. DOCUMENT & CERTIFY RESULTS ON SHEET 4.

4. CLEANLINESS REQUIREMENTS

4.1. ALL ACCESSIBLE SURFACES SHALL BE VISIBLY FREE OF CUTTING FLUID, TAPE RESIDUE, MACHINE CHIPS, GREASE, OIL, FLUX, DIRT, GRIT, SCALE, RUST, SMEARED METAL OR

OTHER FOREIGN MATERIAL. THIN FILMS OF TIGHTLY ADHERENT RUST OR OXIDE ARE

ACCEPTABLE. IF EQUIPMENT COMPONENTS REQUIRE ASSEMBLY, ALL ACCESSIBLE

SURFACES SHOULD BE INSPECTED AND CLEANED AS NECESSARY PRIOR TO ASSEMBLY.

5. MARKING REQUIREMENTS

5.1 . MARK PER MIL-STD-792, TYPE I (VIBRATING TOOL), TYPE II (ELECTROCHEMICAL) OR TYPE

VII (ENGRAVING) A 2.5" DIAMETER CIRCULAR SCRIBE LINE ABOUT EACH OF THE SPECIFIED

HOLES LOCATION SHOWN ON SHEET 4.

5.1.1. USE APPROXIMATELY .1" THICK LINES. DO NOT EXCEED .02" DEPTH.

5.2. MARK PER MIL-STD-792, TYPE I (VIBRATING TOOL), TYPE II (ELECTROCHEMICAL} OR TYPE

VII (ENGRAVING) THE FOLLOWING ON THE SPECIFIED SURFACES:

"RF-6600, LIN 0001 WT: [XXX] LB"

5.2.1. USE -1" TALL X -.5" WIDE CHARACTERS. DO NOT EXCEED .02" DEPTH.

5.2.2. [XXX] IS THE ACTUAL WEIGHT OF ASSEMBLY.

5.3. MARK PER MIL-STD-792, TYPE I (VIBRATING TOOL), TYPE II (ELECTROCHEMICAL) OR TYPE

VII (ENGRAVING) THE FOLLOWING OUTSIDE EACH OF THE MARKED 0 2" SCRIBE LINES:

"WLL 2500 LB, INSPECTION DATE [MM/DD/YYY] , PERIODIC INSPECTION [MM/DD-1/YYYY+3]"

5.3.1. (MM/DD/YYYY] IS THE DATE THE LOAD TEST WAS PERFORMED.

5.3.2. [MM/DD-1/YYYY+3] IS 3 YEARS, MINUS 1 DAY, FROM THE DATE OF THE LOAD TEST.

5.3.3. USE - .25" TALL X - .12" WIDE CHARACTERS. DO NOT EXCEED 0.02" DEPTH.

6. DOCUMENTATION REQUIREMENTS

6.1 . PROVIDE A COMPLETED COPY OF SHEET 4 TO THE REQUESTING AGENCY.

NIA

NEXT ASSY I USED ON

APPLICATION

4 3

2 1

REVISION HISTORY

REVI DESCRIPTION DATE APPROVED

CHANGES MADE TO PC #1 (XY SHIELD BASE - £.f

~1/7~1'( A I 2370B0000097, REV-A), CHANGES MADE TO PC #2

SEATING PLATE - 2370B0000099, REV-A

12/12-/18 1· f{~ lf71J8 ll)z;fg

0 0 0

5 SOCKET HEAD SCREW I ALLOY STEEL 4

4 FLAT HEAD SCREW I ALLOY STEEL 6

3 SHIELD BAR I UNS S30400 1

2 SEATING PLATE

1 XY SHIELD BASE

PC# I DESCRIPTION

DECIMAL TOLERENCES:

X.X = ± 0 .1 x.xx = ± 0.0 1 x.xxx = ± 0.005 x.xxxx = ± 0.0005

UNLESS OTHERWISE SPECIFIED,

DIMENSIONS ARE IN INCHES.

UNS S30400 3

UNS S30400 1

MATERIAL I QTY

APPROVAL/CONCURRENCE

I SIGNATURE I DATE

SUPV. IS/ JEFF WILSON 10/25/18

3/8-16 UNC 3A, 1.25" LG, ASTM A57 4, ZINC PL

1/2-13 UNC 3A, 3.50" LG, ASTM B18.3, ZINC PL

MFG PER 2370B0000100

MFG PER 2370B0000099

MFG PER 2370B0000097

REMARKS

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITIERY, ME

FRACTIONS: ± 1/32

ANGLES: ± 0.5°

DRAWING DIMENSIONAL &

GEOMETRIC TOLERENCES

PER ASME Y14.5-2009

PEER. /SI RYAN KNIGHT 10122118 •TITLE

THIRD ANGLE PROJECTION

I

ORIG. IS/ AKHILA WIJAYARATNE I 10/17/18

CODEI SIGNATURE IDATE

2370.2 l/S/ MIKE CASTELLON 10/25/1 8

2370.4 l/S/ ZACH WISE

NNSY

101221 18 1

SIZE

B

XY SHIELD

(RF-6600, LIN 0001)

DRAWING NO.

2370B0000095 A -$--E3- 1 :6 'WEIGHT -526 LB HEET SHEET 1OF4

2 1 c

B

A c

B_

A

ASSEMBLY

TORQUE 10-12 FT-LB_/

u I

I

Of:

l

~-TORQUE 26-28 FT-LB

l :

l 0

I &

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

SIZE ICAGE CODE DRAWIN REV

B 81316 2370B0000095 A

. - 1 :6 WEIGHT -526 LB HEET SHEET 2 OF 4

c

A

MARKING

(Q) 0

0 0

(Q) ~)

MARKING SPECIFICATION 1 & 3

(NOTE 5.1 & 5.3)

(J . 0 )

MARKING SPECIFICATION 1 & 3

(NOTE 5.1 & 5.3)

0 (Q) 0 0 0 0 r· . 0

~MARKING SPECIFICATION 2

(NOTE 5.2)

RF-6600, LIN. 0001, XXX LB

0 0

0 0

MARKING SPECIFICATION 1 & 3

(NOTE 5.1 & 5.3)

SIZE

B

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

DRAWING NO.

81316 237080000095 A CALE 1 :5'WEIGHT -526 LB rHEET SHEET 3 oF 4 c

A

4 3

LOAD TEST

CERTIFICATION

RESULTS OF TORQUE BASED LOAD TEST ON THE SPECIFIED HOLES

REQUIREMENT HOLE 1 HOLE2 HOLE3

PRE-TEST VISUAL

INSPECTION (1X)

APPLIED TORQUE

(FT-LB)

HOLD TIME

(MINUTES, SECONDS)

POST-TEST VISUAL

INSPECTION (1X)

INSTRUCTIONS

1. PRE-TEST VISUAL: INITIAL & DATE EACH BLOCK UPON SATISFACTORY COMPLETION

OF THE ACTION.

2. RECORD APPLIED TORQUE IN FT-LBF IN THE BLOCK.

3. RECORD HOLD TIME IN MINUTES IN THE BLOCK.

4. POST-TEST VISUAL: INITIAL & DATE EACH BLOCK UPON SATISFACTORY

COMPLETION OF THE ACTION.

5. RECORD DEFICIENCIES AND COMMENTS BELOW:

INSPECTOR SIGNATURE: DATE:

RESULTS OF POST-LOAD TEST INSPECTIONS ON THE SPECIFIED HOLES

REQUIREMENT HOLE 1 HOLE2 HOLE3

NOT (PT/5X)

INSPECTION

GO/NO-GO

THREADS

INSTRUCTIONS

1. INITIAL & DATE EACH BLOCK UPON SATISFACTORY COMPLETION OF THE ACTION.

2. RECORD DEFICIENCIES AND/OR COMMENTS BELOW:

INSPECTOR SIGNATURE: DATE:

4 3

HOLE2

(NOTE 3)

0 0

HOLE 3

(NOTE 3)

SIZE

B

HOLE 1

(NOTE 3)

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

ORA'

81316 237080000095 I A

1 :6 'WEIGHT -526 LB FHEET SHEET 4 OF 4

c

A

4 3

1. MANUFACTURING REQUIREMENTS

1.1. WHERE MIL-SPECS, STANDARDS, TECHNICAL PUBLICATIONS AND/OR

REFERENCE DRAWINGS ARE NOTED, THE LATEST REVISION SHALL BE

IN EFFECT UNLESS OTHERWISE SPECIFIED.

1.2. BREAK ALL SHARP EDGES TO A 1/64" CHAMFER (OR SMALLER).

1.3.ALL SURFACES MUST HAVE A 125 RA FINISH (OR BETTER).

2. WELDING & NON-DESTRUCTIVE TESTING (NOT) REQUIREMENTS

2.1 .NONE.

3. LOAD TEST & NON-DESTRUCTIVE TESTING (NOT) REQUIREMENTS

3.1 . COMPONENT WILL BE LOAD TESTED PER ASSEMBLY DRAWING.

4. CLEANLINESS REQUIREMENTS

4.1. ALL ACCESSIBLE SURFACES SHALL BE VISIBLY FREE OF CUTTING

FLUID, TAPE RESIDUE, MACHINE CHIPS, GREASE, OIL, FLUX, DIRT, GRIT,

SCALE, RUST, SMEARED METAL OR OTHER FOREIGN MATERIAL. THIN

FILMS OF TIGHTLY ADHERENT RUST OR OXIDE ARE ACCEPTABLE. IF

EQUIPMENT COMPONENTS REQUIRE ASSEMBLY, ALL ACCESSIBLE

SURFACES SHOULD BE INSPECTED AND CLEANED AS NECESSARY

PRIOR TO ASSEMBLY.

5. MARKING REQUIREMENTS

5.1. MARKINGS WILL BE APPLIED PER ASSEMBLY DRAWING.

6. HEAT TREAT REQUIREMENTS

6.1 .NONE.

2370B0000098 I RF-6600

237080000095 I RF-6600

NEXT ASSY I USED ON

APPLICATION

REV

A

1 PLATE

PC# DESCRIPTION

DECIMAL TOLERENCES:

x.x = ± 0.1 x.xx = ± 0.01 x.xxx = ± 0.005 x.xxxx = ± 0.0005

FRACTIONS:± 1/32

ANGLES: ± 0.5°

UNLESS OTHERWISE SPECIFIED,

DIMENSIONS ARE IN INCHES.

DRAWING DIMENSIONAL &

GEOMETRIC TOLERENCES

PER ASME Y14.5-2009

THIRD ANGLE PROJECTION

I

-@-B

REVISION HISTORY

DESCRIPTION

CHG. 12.41 DIM (SHT 2, 81),

CHG. HOLE LOC. (SHT 2 , A3

0 0

G

G 0

G

G

DATE APPROVED

I z/ 12/1<t

G

UNS S30400 1

MATERIAL QTY

APPROVAL/CONCURRENCE

SIGNATURE DATE

SUPV. /SI JEFF W ILSON 10125118

PEER. /SI RYAN KN IGHT 10122118 !TITLE

ORIG. /SI AKHILA WIJAYARATNE 10117118

CODEI SIGNATURE DATE

SIZ

SCALE

REMARKS

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

CAGE CODE

XY SHIELD, BASE

(RF-6600)

REV

81316 237080000097 I A 1 :6 'WEIGHT -400 LB fHEET SHEET 1 OF 3 c

Cl I

2X 11.907 1 I

2X 17.596

B

A

4 3 2 1

40.86 ·r L§J @] I Ji 1- 4X I 18.888 I J 14781 :-1 ~2xl9.s62I ·1

2X I 13.410 I I 781 H & I I I I I .. I & I .. ·I 3.000 :1°g~

I I I

-e- -e- ..,., I ~J

1 -r 1 BX 15.705 _r ti ti

LL __ _ _1.J __

- - - - _I_ - - - -

__ LL ___ _ __ .1.J __

ff_& l-__---i 9.5621------l

,.. .., 2X [2.020 I i-------+---2X 14.040 I

.____---------------6X 0.531 THRU

'-----------------2X 0 3.50 THRU

V 0 3.75 X82°

V 0 .97 X82° l-$-10 .010 @I BI A I

~------5X 1/2-13 UNC l-$-10 .01o®J s 1Aic1

4X 0 1.625 :gdl THRU

LJ 0 2.375 T 1.510

l-$-10 .0051 BI A I c I

T 1.125 MAX TAP DRILL

T .875 MIN FULL THREAD

l-$-10 .010 @ 4.00 ®I BI A I

3 2 r--

1 u:::--

L--

12.4~

J:~ I _r., _l ti

I I

11.00IJ

1.00 :gd A A

L_ _J

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

2370800000971 A 1 :4 IWEIGHT -400 LB fHEET SHEET 2 OF 3 le

IB

I sl · I

A

4 3 2

---------2X 111 .000 2X 17.000 f--------r- I I

L1--1

I

4x1.600 I

1.00 +.01 -.00

1A

~J-------lJ ]---(

L.. _.I IL..__.

I

I

I

I

4X 3/8-16 UNC 2B

T 1.000 MAX TAP DRILL

T .688 MIN FULL THREAD

l-t11-l 0 .0101 BI A I c I

I I I I I I

I I I r- -r I I I I I I

I I

VIEW A-A

ROTATED 90°

111 ii h-il L.. __.

I r . r- --( I I I I

I I I I L111- -1 _J

I I

I -EB- -9-1

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

IZE I CAGE CODE DRAWING NO.

B 81316 237080000097 c

Is

A

REV

A 1 :21WEIGHT -400 Ls rHEET sHEET 3 oF 3

4 I 3

1. MANUFACTURING REQUIREMENTS

1.1. WHERE MIL-SPECS, STANDARDS, TECHNICAL PUBLICATIONS AND/OR

REFERENCE DRAWINGS ARE NOTED, THE LATEST REVISION SHALL BE

IN EFFECT UNLESS OTHERWISE SPECIFIED.

1.2. BREAK ALL SHARP EDGES TO A 1/64" CHAMFER (OR SMALLER).

1.3.ALL SURFACES MUST HAVE A 125 RA FINISH (OR BETTER).

2. WELDING & NON-DESTRUCTIVE TESTING (NOT) REQUIREMENTS c I 2.1.NONE.

3. LOAD TEST & NON-DESTRUCTIVE TESTING (NOT) REQUIREMENTS

3.1.NONE.

4. CLEANLINESS REQUIREMENTS

4.1. ALL ACCESSIBLE SURFACES SHALL BE VISIBLY FREE OF CUTTING

FLUID, TAPE RESIDUE, MACHINE CHIPS, GREASE, OIL, FLUX, DIRT, GRIT,

SCALE, RUST, SMEARED METAL OR OTHER FOREIGN MATERIAL. THIN

FILMS OF TIGHTLY ADHERENT RUST OR OXIDE ARE ACCEPTABLE. IF

- EQUIPMENT COMPONENTS REQUIRE ASSEMBLY, ALL ACCESSIBLE

SURFACES SHOULD BE INSPECTED AND CLEANED AS NECESSARY

PRIOR TO ASSEMBLY.

B

A

5. MARKING REQUIREMENTS

5.1. NONE.

6. HEAT TREAT REQUIREMENTS

6.1.NONE.

237080000096 I RF-6600

237080000095 I RF-6600

2370B0000094 I RF-6600

NEXT ASSY I USED ON

APPLICATION

I 2 I 1

REVISION HISTORY

REV DESCRIPTION DATE APPROVED

A IOD CHG., ID CHG. (SHT 2, A3), HOLE LOC. (SHT 2, B2)1 12/iz/i~ ~. ~JJQ((Jq 11 If'~ tz/tz/IB

'f,V4nl'1

1 TUBE

PC# DESCRIPTION

DECIMAL TOLERENCES:

x.x = ± 0.1

X.XX = ± 0.01

x.xxx = ± 0.005 x.xxxx = ± 0.0005

FRACTIONS: ± 1/32

ANGLES: ± 0.5°

UNLESS OTHERWISE SPECIFIED,

DIMENSIONS ARE IN INCHES.

DRAWING DIMENSIONAL &

GEOMETRIC TOLERENCES

PER ASME Y14.5-2009

THIRD ANGLE PROJECTION

I

*--Et I

UNS S30400 1

MATERIAL QTY

APPROVAL/CONCURRENCE

I SIGNATURE I DATE

SUPV. IS/ JEFF WILSON 10/25/ 18

REMARKS

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

PEER. /SI RYAN KNIGHT 10122118 ·TITLE

ORIG. l/S/ AKHILA WIJAYARATNE I 10/ 17/18

CODE SIGNATURE I DATE

SEATING PLATE

(RF-6600)

SIZE CAGE CODE DRAWING NO. REV

B 81316 2370B0000099 A SCALE 1 :2 IWEIGHT 40 LB fHEET SHEET 1 OF 2

I 1 c

B

4 I 3 I

9.562

4.781 cl I I L.___

B

--- ¢ 8.75 ±.010 & A --- ¢ 10.38 ±.010 & -----'

4 3

2.740 ±.005

2X 1/2-13 UNC 28

T 1.000 MAX TAP DRILL

T .750 MIN FULL THREAD

l-$-10 .010 @I BI A I

1~ ·1 L--- - ---b d-J.

L -- ----

PORTSMOUTH NAVAL SHIPYARD

NUCLEAR REFUELING ENGINEERING DIVISION

CODE 2370 - KITTERY, ME

0 .

237080000099 A SCALE 1 :2'WEIGHT 40 LB rHEET SHEET 2 oF 2 c

File details come from the government source that posted it.