J&A USNS MERCY N3220520R6500 Redacted.pdf
PDF 187 KB Posted
- Attached to
- USNS MERCY ROH/DD Federal contract opportunity
- Solicitation number
- N3220520R6500
About this file
This justification and approval document outlines thirty-three sole source work items for the regular overhaul and drydocking of the USNS Mercy. The work items require original equipment manufacturers or authorized vendors to provide technical representatives and proprietary parts for critical ship systems and equipment. Products and services include inspection and maintenance of main propulsion components, generators, medical systems, lifesaving equipment, and more. The total value of the sole source work items is TBD. The justification cites factors such as safety, technical requirements, warranties, and the lack of equivalent alternatives to support restricting competition. The Navy intends to post a solicitation for the overhaul project, requiring any awardees to use the specified sole source vendors for the work items.
View the file
Other files for this federal contract opportunity
Show all 50
USNS MERCY ROH/DD has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J & A No. N3220520R6500
JUSTIFICATION AND APPROVAL (J&A) FOR USE OTHER THAN FULL AND OPEN
COMPETITION
1. Contracting Activity: Department of the Navy, Military Sealift Command (MSC) Norfolk
2. Description of the Action Being Approved: This is a sole source justification for work to be provided under Work Items (WIs): 0252, 0254, 0286, 0287, 0292, 0301, 0451, 0452, 0453, 0455, 0456, 0459, 0490, 0491, 0501, 0502, 0509, 0518, 0562, 0563, 0601, 0602, 0603, 0604, 0605, 0650, 0653, 0701, 0702, 0705, 0802, 0909 and 0912 of the Statement of Work (SOW) for the Regular Overhaul and
Drydocking (ROH) of the USS MERCY (T-AH 19) under RFP N3220520R6500. This Justification is covering only the portion of the acquisition, which is brand-name, or otherwise sole source and the approval level requirements will then only apply to the portion.
3. Description of Supply Services: MSC Norfolk requires Original Equipment Manufacturer (OEM) authorized technical field representatives and OEM parts to accomplish requirements of WIs listed below. The estimated combined dollar value of the thirty-three (33) Work Items is that will be funded utilizing FY 20 Operation / Maintenance and ESLP funds.
Work Items Requiring Service Representative(s):
0252: Main Reduction Gear Inspection (5 YR)
0254: Thrust and Line Shaft Bearing Inspection (5 YR)
0286: HP and LP Steam Turbine Open and Inspect (5 YR)
0287: Automation and Propulsion Control Inspect and Test
0292: Main Feed Pump Overhaul
0301: ENCON-HEAT Balance Instrumentation Install
0451: Annual Radar Service (1 YR)
0452: Annual ECDIS Service (1 YR)
0453: Annual Gyro Service (1 YR)
0455: Annual Radio Communications Equipment Recertification (1 YR)
0456: Magnetic Compass Service (2YR)
0459: ECHO Sounder Service (1 YR)
0490: Speed Log (5 YR)
0491: Annual SVDR Recertification (1 YR)
0501: ESLP- TLI Sensor Installation Phase 2
0502: ESLP- TLI Sensor Installation Phase 2
0509: ESLP- ADG Overhaul
0518: ESLP- SSTG Overhaul
0562: SCBA annual Inspection
0563: SCBA Air Compressor and Fill Station Inspection
0601: Tender Boat Davit Service (1 YR)
0602: Tender Boat Service (1 YR)
0603: Rescue Boat Davit Repairs
0604: Deck Crane Inspection (5 YR)
0605: Life Raft Davit Service (1 YR)
0650: ESLP-Life Boat Replacement
0653: Annual Rescue Boat and Davit Inspection (1 YR)
0701: O2N2 System Inspection and Groom (2 YR)
0702: O2N2 LPAC Compressor Inspect and Groom (1 YR)
0705: Paitent Litter Hoist Inspection (2.5 YR)
0802: No 1 A/C Condenser Retube
0909: Cathodic Protection System Inspection
0912: Shaft Seal Inspection and Replace
4. Statutory Authority Permitting Other Than Full and Open Competition: 10 U.S.C 2304 (c) (1):
Only one responsible source and no other supplies or services will satisfy agency requirements (as implemented by FAR 6.302-1(a)).
5. Rationale Justifying Use of Cited Authority:
a. WI 0252: Main Reduction Gear Inspection (5 YR)
This work requires the services of a MSC N7 Recognized Repair Facility from the following recognized list: Curtiss-Wright, MI-Tech Inc., PJ Schwalbenberg & Associates Inc. for parts and servicing of the vessels Main Reduction Gear (MRG). The MRG is critical equipment per Safety
Management System (SMS) #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. A loss of the MRG will result in the ship being dead in the water putting the crew and vessel safety at risk. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the OEM service and replacement parts.
b. WI 0254: Thrust and Line Shaft Bearing Inspection (5 YR)
This work requires a Waukesha Bearing Technical Representative to service the vessels Main
Propulsion Shaft Thrust and Line Shaft Bearings. The Main Propulsion Shaft is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide
OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the OEM service and replacement parts.
c. WI 0286: HP and LP Steam Turbine Open and Inspection (5 YR) recognized list: Curtiss-Wright, MI-Tech Inc., PJ Schwalbenberg & Associates Inc. for parts and servicing of the vessels HP and LP TurbCOines. The HP and LP Turbines are critical equipment per Safety Management System (SMS) #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. A loss of the HP and
LP Turbines will result in the ship being dead in the water putting the crew and vessel safety at risk. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company.
Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the OEM service and replacement parts.
d. WI 0287: Automation and Propulsion Control Inspect and Test
This work requires a Technical Marines Services Technical Representative to service the ship’s
Automation and Propulsion and Control system. The Automation and Propulsion and Control system is critical equipment per SMS #10.6-002-01-AH.
Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the
OEM service and replacement parts.
e. WI 0292: Main Feed Pump Overhaul
This work requires a Coffin Turbo Pump Technical Representative to overhaul the ship’s Main
Feed Pumps. The Main Feed Pumps are critical equipment per SMS #10.6-002-01-AH. Only
OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company.
Notwithstanding the rationale above, MSC further does not have the manufacturing and technical
f. WI 0301: ENCON-HEAT Balance Instrumentation Install
This work requires a Technical Marine Services Technical Representative to install and commission the new Heat Balance Instrumentation for the Propulsion Plant. The Propulsion Plant is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all
OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-
OEM service and replacement parts are equivalent to the OEM service and replacement parts.
g. WI 0451: Annual Radar Service (1 YR)
This work requires a Furuno Technical Representative to service the ship’s Furuno model FAR
2827S/12 and FAR 2837 radars, and radar uninterrupted power supplies (UPS). The radars are critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of navigation at sea. OEM-authorized
Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
h. WI 0452: Annual ECDIS Service (1 YR)
This work requires a Transas Technical Representative to service the ship’s Navi-Salor 4000
EDCIS. The ECDIS is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services.
Incorrectly, installed or deficient parts could cause system failure and loss of navigation at sea.
OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company.
Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non- OEM service and replacement parts
i. WI 0453: Annual GYRO Service (1 YR)
This work requires the supply of a Sperry Marine Technical Representative to service the ship’s main gyrocompass, model WSN-7B, and auxiliary gyrocompass, model MK23. The gyrocompasses are critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of navigation at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
j. WI 0455: Annual Radio Communication Equipment Cert (1 YR)
This work requires a Manufacturer’s Authorized Technical Representative IAW ABS recognized external specialists to service the ship’s radio communication equipment. The radio equipment is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of communication at sea. OEM-authorized
Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
k. WI 0456: Magnetic Compass Service (2 YR)
This work requires a Manufacturer’s Authorized Technical Representative to inspect and service the ship’s Baker Lyman Magnetic Compass. The Magnetic Compass is critical equipment per SMS
#10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of depth detection at sea. OEM-authorized Representatives will only install genuine
OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not
l. WI 0459: Echo Sounder Service (1 YR)
This work requires a Manufacturer’s Authorized Technical Representative to inspect and service the ship’s Echo Sounder systems, FURUNO models: FE8020, 50B-6B, 200B-8B, FE8010, and
RD-50. The Echo Sounder is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services.
Incorrectly, installed or deficient parts could cause system failure and loss of depth detection at sea.
OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company.
Notwithstanding the rationale above, MSC further does not have the manufacturing and technical
m. WI 0490: Speed Log Servicing (5 YR) the ship’s Speed Log system, FURUNO model: DS-80. The Speed Log is critical equipment per
SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide
OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of depth detection at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all
OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not
n. WI 0491: Annual SVDR Recertification (1 YR) the ship’s Simplified Voyage Data Recorder (S-VDR), JRC model: JCY-1850. The S-VDR is critical equipment per SMS #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure and loss of log data for accident investigation in event of casualty at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the OEM service and replacement parts.
o. WI 0501: ESLP-TLI Sensor Install Phase 2
This work requires a NAG Marine Technical Representative to install and commission Phase 2 of the new Remote Tank Level Indication System. NAG Marine is the OEM for the Remote Tank
Level Indicating System, has access to proprietary drawings/technical data, and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine
p. WI 0502: ESLP-TLI Sensor Install Phase 3
This work requires a NAG Marine Technical Representative to install and commission Phase 3 of the new Remote Tank Level Indication System. NAG Marine is the OEM for the Remote Tank
Level Indicating System, has access to proprietary drawings/technical data, and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause system failure at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine
q. WI 0509: ESLP- ADG Overhaul recognized list: MAN Diesel North America or Motor Service Hugo Stamp for parts and servicing of the vessels Auxiliary Diesel Generator Engines Model: 12V25/30. The Auxiliary Diesel
Generator Engines are critical equipment per Safety Management System (SMS) #10.6-002-01-
AH. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. A loss of Auxiliary Diesel Generator Engine results in loss of mission critical electrical generation which when at sea affects crew, medical services, and vessel safety. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
r. WI 0518: SSTG Open and Inspect (5 YR) recognized list: Curtiss-Wright, MI-Tech Inc., PJ Schwalbenberg & Associates Inc. for parts and servicing of the USNS Mercy’s SSTG Turbine. The SSTG Turbine is critical equipment per Safety
Management System (SMS) #10.6-002-01-AH. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. A loss of the SSTG Turbine will result in a loss of the critical electrical generation which when at sea affects crew, medical services, and vessel safety. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and
s. WI 0562: SCBA Annual Inspection (1 YR)
This work requires Manufacturers authorized service facility and Technical Representative IAW
ABS recognized external specialists to service the ship’s Self-Contained Breathing Apparatus
(SCBA) equipment. Only OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause SCBA equipment failure and loss of firefighting capability at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine
t. WI 0563: SCBA Compressor and Fill Station Inspect and Maint (1 YR)
This work requires a Manufacturer authorized service facility and Technical Representative to service the ship’s Self-Contained Breathing Apparatus (SCBA) compressor and refill station. Only
OEM-authorized service and parts providers have access to proprietary drawings/technical data and have the expertise and knowledge to identify and provide OEM parts, components, and qualified services. Incorrectly, installed or deficient parts could cause SCBA equipment failure and loss of firefighting capability at sea. OEM-authorized Representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the
u. WI 0601: Annual Tender Boat Davit Service (1 YR)
The work item requires a FASSMER Service America Technical Representative for the annual requirement to inspect, service, and test the ship’s Tender Boat launching appliances, and releasing gear. The Tender Boat davits are critical safety equipment per SMS #10.6-002-01-AH in the event of emergency escape or similar situation. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide
OEM parts, components, and qualified services. The loss of the Tender Boat Davits can result in the inability safely evacuate personnel in an emergency escape situation. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
v. WI 0602: Annual Tender Boat Service (1 YR)
The work item requires a FASSMER Service America Technical Representative for the annual requirement to inspect, service, and test the ship’s Tender Boats. The Tender Boats are critical safety equipment per SMS #10.6-002-01-AH in the event of emergency escape or similar situation.
Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the Tender Boats can result in the inability safely evacuate personnel in an emergency escape situation. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the
w. WI 0603: Rescue Boat Davit Repairs
The work item requires an Allied Systems Company Technical Representative to accomplish the repairs to the two (2) Rescue Boat Davits. The Rescue Boat Davits are critical safety equipment per
SMS #10.6-002-01-AH in the event of man overboard or similar situation. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of rescue boat can result in the inability safely retrieve personnel in the water-awaiting rescue. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
x. WI 0604: Deck Crane Inspection (5 YR)
The work item requires an Allied Systems Company Technical Representative for the requirement to inspect, service, and test the ship’s five (5) Deck Cranes. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the Deck Cranes can result in the inability safely launch the Utility Boats, Force Protection Boats and load/unload material from the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the
y. WI 0605: Life Raft Davit Annual Servicing (1 YR)
The work item requires a Manufacturer’s Authorized Technical Representative for the annual requirement to inspect, service, and test the ship’s life raft launching appliances. The life rafts and davits are critical safety equipment per SMS #10.6-002-01-AH in the event of emergency escape or similar situation. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of lifeboats can result in the inability safely evacuate personnel in an emergency escape situation. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all
OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not
z. WI 0650: ESLP-Life Boat Replacement
The work item requires a Manufacturer’s Authorized Technical Representative for the installation, testing and commissioning of the new lifeboats, launching appliances, and releasing gear. The lifeboats, launching appliances, and releasing gear are critical safety equipment per SMS #10.6-
002-01-AH in the event of emergency escape or similar situation. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the
Lifeboats and Launching Appliances, and Releasing Gear can result in the inability safely evacuate personnel in an emergency escape situation. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all
OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not
aa. WI 0653: Annual Rescue Boat and Davit Inspection (1 YR)
The work item requires an Allied Systems Company Technical Representative for the annual requirement to inspect, service, and test the ship’s rescue boats, launching appliances, and releasing gear. The rescue boats are critical safety equipment per SMS #10.6-002-01-AH in the event of man overboard or similar situation. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of rescue boat can result in the inability safely retrieve personnel in the water-awaiting rescue. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all
OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not
bb. WI 0701: O2N2 System Inspection and Groom (2 YR)
The work item requires a Cold LLC Technical Representative for the annual requirement to inspect, and recertify the O2N2 System onboard. The O2N2 System generates and provides
Oxygen and Nitrogen to support medical treatment of patients the Medical Treatment Facility onboard. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the O2N2 System will severely reduce the ability of the Medical
Treatment Facility to treat patients, the primary mission of the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
cc. WI 0702: O2N2 LPAC Inspection and Groom (1 YR)
The work item requires an Ingersoll Rand Technical Representative for the annual requirement to inspect, and recertify the O2N2 System onboard. The O2N2 System generates and provides
Oxygen and Nitrogen to support medical treatment of patients the Medical Treatment Facility onboard. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the O2N2 System will severely reduce the ability of the Medical
Treatment Facility to treat patients, the primary mission of the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required
dd. WI 0705: Patient Litter Hoist Inspect (2.5 YR)
The work item requires a Manufacturer’s Technical Representative for the annual requirement to inspect, and test the Patient Litter Hoist’s onboard. The Patient Litter Hoist’s provides the means to lift immobile Patients in the Medical Treatment Facility on/off the vessel. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the
Patient Litter Hoist’s will severely reduce the ability of the vessel to lift Patients on/off vessel for medical treatment, the primary mission of the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the OEM service and replacement parts.
ee. WI 0802: N0 1 A/C Condenser Retube
Retube the No 1 A/C condenser. The No 1 A/C Plant provides air condition to the Medical
Treatment Facility onboard. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the No 1 A/C Plant will severely reduce the ability of the vessel to provide A/C to the Patients in the Medical Treatment Facility onboard, the primary mission of the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the
ff. WI 0909: Cathodic Protection System Inspection inspect, and test the Cathodic Protection System onboard. The Cathodic Protection system provides
Corrosion Control for the underwater Hull of the vessel. Only OEM-authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. The loss of the Cathodic
Protection System will severely increase the chances for steel wastage on the underwater Hull of the vessel. OEM-authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and
gg. WI 0912, Shaft Seal Inspection and Replacement
This work requires a Wartsila Defense Inc. Technical Representative as the sole-source OEM for parts and servicing of the vessels Propulsion Shaft Seal. The Propulsion Shaft Seal is critical equipment per Safety Management System (SMS) #10.6-002-01-AH. Only OEM- authorized service and parts providers have access to proprietary drawings and technical data, and have the expertise and knowledge to provide OEM parts, components, and qualified services. A loss of the
Propulsion Shaft Seal results in loss of main propulsion of the vessel and possible flooding of the
Main Machinery Space, which will put the crew and vessel safety at risk. OEM- authorized representatives will only install genuine OEM parts supplied from within the authorized distributor network. This maintains all OEM warranties and ensures equipment reliability, therefore precluding consideration of a product manufactured by another company. Notwithstanding the rationale above, MSC further does not have the manufacturing and technical information required to evaluate and determine whether non-OEM service and replacement parts are equivalent to the
4. Description of Efforts Made to Solicit Offers from as Many Offerors as Practicable: The requirement has been synopsized at the Government Point of Entry (GPE), FedBizOps website, and the
Government intends to post a Request for Proposal (RFP) along with this justification at the GPE with the intent of awarding a firm-fixed price contract to the lowest price offeror. Any prospective contractor will be required to use the OEM or OEM Authorized vendor as a subcontractor to perform the work in the related WIs.
5. Determination of Fair and Reasonable Cost: The Contracting Officer will determine the anticipated cost to the Government of the supplies/services covered by this J&A will be fair and reasonable.
6. Actions to Removed Barriers to Future Competition: For reasons set forth in Paragraph 5, MSC has no plans at this time to allow prime contractors to solicit these requirements competitively, other than synopsizing the requirements. If another potential source emerges, MSC Norfolk will assess whether competition for future requirements is feasible. .
File details come from the government source that posted it. Updated .