This document contains answers to questions from potential offerors regarding solicitation number N3220520R4088 for post-shakedown availability and drydocking of the USNS Puerto Rico with the Military Sealift Command. The questions pertained to specification items for work involving an e-console interface, greywater three-way valve, CHT washdown modification, CHT transfer pump, waste oil pump strainer, and stern ramp piping. The answers clarified that the relevant references would be resent via DOD SAFE. Additionally, a question regarding heat trace installation referenced an existing system, and electrical drawings would be required upon job completion.

View the file

Other files

File Type Posted
USNS PUERTO RICO N3220520R4088 solicitation(updated).pdf PDF
USNS PUERTO RICO N3220520R4088 Solicitation(updated).pdf PDF
Q AND A Responses 6.pdf PDF
N3220520R4088 Amendment 0006.pdf PDF
J - 2 CAT A ITEMS USNS PUERTO RICO 20R4088.xlsx XLSX spreadsheet
J - 1 Work Item Index USNS PUERTO RICO 20R4088.docx DOCX document
N3220520R4088 Amendment 0005.pdf PDF
Q AND A Responses 5.pdf PDF
N3220520R4088 Amendment 0004.pdf PDF
Q AND A Responses 4.docx DOCX document
N3220520R4088 Amendment 0003.pdf PDF
N3220520R4088 Amendment 0002.pdf PDF
Q AND A Responses 3.docx DOCX document
N3220520R4088 Amendment 0001.pdf PDF
Q AND A Responses 1.pdf PDF
J - 7 MSC Ship Repair Facility Survey - PUERTO RICO 20R4088.docx DOCX document
J - 12 Past Performance Data - PUERTO RICO 20R4088.doc DOC document
J - 11 Dry Dock Evaluation Form - PUERTO RICO 20R4088.docx DOCX document
J - 14 Technical Data Non-Disclosure - PUERTO RICO 20R4088.docx DOCX document
J - 1 Work Item Index USNS PUERTO RICO 20R4088.docx DOCX document
J - 9 Disclosure of Lobbying Activities - PUERTO RICO 20R4088.doc DOC document
J - 8 Request for Spec Clarification - PUERTO RICO 20R4088.doc DOC document
J - 6 CDRLs USNS PUERTO RICO PSA.zip ZIP file
J - 2 CAT A ITEMS USNS PUERTO RICO 20R4088.xlsx XLSX spreadsheet
J - 3 CAT B ITEMS USNS PUERTO RICO 20R4088.xls XLS spreadsheet
USNS PUERTO RICO PSADD N3220520R4088 Solicitation.pdf PDF
J - 10 Interport Differential - PUERTO RICO 20R4088.doc DOC document
J - 4 GFP Listing.xlsx XLSX spreadsheet
J - 13 Past Performance Questionnaire - PUERTO RICO 20R4088.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MILITARY SEALIFT COMMAND

N3220520R4088

QUESTIONS AND ANSWERS 2

The following are answers to questions received from potential offerors. The answers provide clarification only and DO

NOT constitute an amendment to the solicitation.

QUESTION #1:

SPECIFICATION ITEM NO.: 406

PARAGRAPH / SECTION NO: 2.1.02

TITLE: E- Console Interface

Reference 2.1.2 was not provided with the solicitation. Please provide.

ANSWER:

Reference 2.1.2 will be resent via DOD SAFE.

QUESTION #2:

SPECIFICATION ITEM NO.: 504

PARAGRAPH / SECTION NO: 2.1.1

TITLE: Greywater 3 Way Valve

Reference 2.1.1 was not provided with the original solicitation. Please provide.

Reference 2.1.2 will be resent via DOD SAFE.

QUESTION #3:

SPECIFICATION ITEM NO.: 505

PARAGRAPH / SECTION NO: 2.1

TITLE: CHT Washdown Mod

Reference 2.1 was not provided with the original solicitation. Please provide the reference.

Reference 2.1 will be resent via DOD Safe.

QUESTION #4:

SPECIFICATION ITEM NO.: 506

PARAGRAPH / SECTION NO: 2.0

TITLE: CHT Transfer Pump

None of the references were provided for this work item. Please provide.

References will be resent via DOD Safe.

QUESTION #5:

SPECIFICATION ITEM NO.: 507

PARAGRAPH / SECTION NO: 2.2

TITLE: Waste Oil Pump Strainer

Reference 2.2 was not provided with the solicitation. Please provide.

Reference 2.2 will be resent via DOD Safe.

QUESTION #6:

SPECIFICATION ITEM NO.: 518

PARAGRAPH / SECTION NO: 2.0

TITLE: Stern Ramp Piping

None of the references were provided for this work item. Please provide.

References will be resent via DOD Safe.

QUESTION #7:

SPECIFICATION ITEM NO.: 524

PARAGRAPH / SECTION NO: 7.8.1

TITLE: Heat Trace

Paragraph 7.8.1 references other items installing heat trace. What other item is the specification referencing for heat trace installation?

A heat trace system was previously installed. Heat trace cabling should be installed on the new hot and cold potable water piping and tied into the existing heat trace system. Electrical load calulations will be required prior to install. Revised electrical drawings for the heat trace system will be required upon completion. Austal USA drawing 430-324-01-714 provided as reference.