N3220518R4013
USNS JOSHUA HUMPHREYS (T-AO 188)
ATTACHMENT J - 8
REQUEST FOR SPECIFICATION CLARIFICATION
RFC _0013__
NAME OF CONTRACTOR: _______________________________________________
SPECIFICATION ITEM NO.: ___0114______________
PARAGRAPH / SECTION NO: ___7.2.10-7.3.3_________________
TITLE: ___FLIGHT DECK PRESERVATION AND NON-SKID__________
QUESTION:
Paragraph 7.2.10 calls for UHP WJ-2 all areas and paragraphs 7.3 -7.3.3 specify SP-
10 and Power Tool Clean SP-11. Are we to perform both or is it our option to choose which method of surface preparation?
ANSWER: Water or shot blast is acceptable for flat surfaces power tool cleaning is for tie downs and inaccessible areas.