J-7 MSC Ship Repair Facility Survey USNS BIG HORN ROH.doc

DOC document 100 KB Posted

Attached to
USNS BIG HORN (T-AO 198) ROH/DD
Solicitation number
N32205-16-R-4010
Issued by

About this file

J-7 MSC Ship Repair Facility Survey

View the file

Other files

File Type Posted
Copy_of_J-3_Category_B_Items_USNS_BIG_HORN_ROH.XLSX XLSX spreadsheet
Amendment_0006.pdf PDF
USNS_Big_Horn_2016_ROH_JA_Revised_Redacted.pdf PDF
Amendment_0005.pdf PDF
Amendment_0004_USNS_BIG_HORN_ROH.docx DOCX document
Question_0022.doc DOC document
Question_0021.doc DOC document
Question_0020.doc DOC document
Amendment_0003.docx DOCX document
Question_0019-_Big_Horn.docx DOCX document
Question_0018-_Big_Horn.doc DOC document
Question_0017-_Big_Horn.doc DOC document
Question_0016-_Big_Horn.doc DOC document
Question_0014_-_Big_Horn.doc DOC document
Question_0013-_Big_Horn.doc DOC document
Amendment_0002.docx DOCX document
Question_0012-_Big_Horn.doc DOC document
Question_0011-_Big_Horn.doc DOC document
Question_0010-_Big_Horn.doc DOC document
Question_0009_-_Big_Horn.doc DOC document
Question_0008_-_Big_Horn.doc DOC document
USNS_BIG_HORN_J A_Revised_Redacted.pdf PDF
Question_0007.docx DOCX document
Question_0006_-_Big_Horn.docx DOCX document
Question_0005_-_Big_Horn.doc DOC document
Question_0004_-_Big_Horn.doc DOC document
Question_0003_-_Big_Horn.docx DOCX document
Question_0002_-_Big_Horn.docx DOCX document
Amendment_0001_USNS_BIG_HORN_ROH.docx DOCX document
Question_0001_-_Big_Horn.docx DOCX document
J-9 Disclosure of Lobbying Activities SF-LLL USNS BIG HORN ROH.doc DOC document
J-3 Category B Items USNS BIG HORN ROH.xlsx XLSX spreadsheet
J-14 NON DISCLOSRE AGREEMENT FOR GOVN'T TECHNICAL DATA —
J-8 Request for Spec Clarification USNS BIG HORN ROH.doc DOC document
J-13 PAST PERFORMANCE QUESTIONNAIRE USNS BIG HORN ROH.docx DOCX document
USNS BIG HORN 2016 J A Signed Redacted.pdf PDF
J-4 USNS BIG HORN ROH.xls XLS spreadsheet
J-11 Dry Dock Evaluation Form USNS BIG HORN ROH.docx DOCX document
J-12 Past Performance Data USNS BIG HORN ROH.docx DOCX document
J-5 Subcontracting Plan USNS BIG HORN ROH.docx DOCX document
J-2 Category A Items USNS BIG HORN ROH.xlsx XLSX spreadsheet
J-10 Interport Differential USNS BIG HORN ROH.doc DOC document
J-6 CDRLS USNS BIG HORN ROH.pdf PDF
USNS BIG HORN DRAFT SOLICITATION.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N32205-16-R-4010

USNS BIG HORN (T-AO 198)

SHEET 1 OF 5

MSC SHIP REPAIR FACILITY SURVEY

NOTE: If survey form has been previously submitted, then enter changes only.

DATE:

SHIPYARD AND ADDRESS

Commander (Code M-4E3)

Military Sealift Command

Norfolk, VA 23511

SHIPYARD DATA

Telephone No:

Telex No:

Date Found:

BUILDING WAYS (M. I. W.)

NO. LAUNCHING DIMENSIONS MAXIMUM SHIP SIZE

OF (check one) (ton 2,240 lbs)

WAY

[ ] END LENGTH: LENGTH:

[ ] SIDE

[ ] BASIN WIDTH: WIDTH:

[ ] SLAB

DEPTH: DEPTH:

DEPTH OF WATER

CRANES SERVING WAY

CERTIFICATION DATE &

CERTIFIED BY WHOM

LIFT CAPACITY

(std. tons)

TYPE

NO.

AT DROP

OFF

OVER

WAY END

[ ] BASIN WIDTH: WIDTH:

[ ] BASIN WIDTH: WIDTH:

[ ] BASIN WIDTH: WIDTH:

[ ] BASIN WIDTH: WIDTH:

[ ] BASIN WIDTH: WIDTH:

LENGTH OF LAUNCHING RUN DEPTH OF RUN AT M.L.W.

TIDAL RANGE (DIFF. OF M.L. M.H)

IS SNUBBING NECESSARY?

YES NO

IS FIRE PROTECTION AVAILABLE

ON BUILDING WAY?

YES NO

DOCK

MAXIMUM SHIP SIZE

ACCOMMODATED

LENGTH OA-BEAM

LENGTH

at coping (GD), at keel blocks

OVERALL on cradle (MR), on PONTOON

(FD)

CLEAR WIDTH

at top cradle (MR), at keel at top inboard block wing wall (FD, GD) height

DEPTH/DRAFT

OVER OVER OVER

SILL FLOOR KEEL

(GD) BLOCKS

LIFTING CAPACITY

(ton 2,240)

DATE CERTIFIED, CERTIFIED BY WHOM, &

DATE CERTIFICATION EXPIRES

DRY DOCKS (continued)

MATERIAL TYPE

Floating--(FD)

Graving--(GD) Marine Railway (MR)

SERVICES AVAILABLE

(use abbreviation of service below)

USE

REPAIR/

OUTFIT-

ING

HEIGHT

OF

(M.L.W.)

OUT-

BOARD

IN-

BOARD

TYPE

LENGTH

(actual & usable)

ACT:

USE:

WATER DEPTH

(M. L. W.)

BERTHS OF SHIPS (Piers, Wharves, Bulkheads, etc.) DRY DOCKS (means high water)

MSC SHIP REPAIR FACILITY SURVEY (continued) SHIPYARD:

LEGEND (abbreviation of services)

Fresh Water --- F.W. - G.P.M. - P.S.I. Steam --- S - P/HR - P.S.I. Electric Power --- E - V - AC - AMP Fire Protection --- FP - G.P.M. - P.S.I.

Salt Water ----- S.W. - G.P.M. - P.S.I Air ------ A - C.F.M. - P.S.I. Electric Power --- E - V- DC - AMP Sanitary Sewer --SS - YES - NO

MSC SHIP REPAIR FACILITY SURVEY (continued) SHIPYARD:

BERTHING, SHOP OR YARD CRANES; STATIONARY, RAIL, MOBILE, OR BRIDGE (3 tons or over)

MAX REACH HEIGHT OF HOOK

NO TYPE CAPACITY MAX SPAN CAPACITY BOOM HEIGHT ABOVE BASE HEIGHT OF HOOK AREA SERVICE DATE CERTIFIED, CERTIFIED BY WHOM &

(STD TONS) (BRIDGE) AT REACH LENGTH HINGE ABOUT REACH (BRIDGE) DATE CERTIFICATION EXPIRES

DISTANCE TO NEAREST DISTANCE TO NEAREST AIRPORT

RAILROAD CONNECTION (identify)

NAVIGATIONAL RESTRICTIONS (indicate at M.L.W.)

MINIMUM CHANNEL (depth width) MINIMUM HORIZONTAL AND VERTICAL BRIDGE CLEARANCES

LIST ANY OTHER RESTRICTIONS (include projects under construction which will after navigational restrictions)

SHIPYARD:

MSC SHIP FACILITY SURVEY (continued)

STORAGE SPACE FOR COMPONENTS AND MATERIALS

(LIST DIMENSIONS FOR EACH AREA, PLUS TYPE MATERIAL STORED)

PRINCIPAL SHOPS AND BUILDINGS

ALL OTHER SHOPS

(LIST NAMES AND DIMENSIONS)

LARGEST EXIT

WIDTH HEIGHT

DIMENSIONS OF

SHOP OR BUILDING

NAME OF SHOP

OR BUILDING

FABRICATING

PLATE

SHEET METAL

SUBASSEMBLY

WOOD WORKING

BOAT ASSEMBLY

OR MOLDING

BOILER

MACHINE

ELECTRICAL

ELECTRONIC

PIPE

FOUNDRY

RIGGER

RAW STEEL STORAGE (SQ. FT.) ___________________________________________________________

WELDING AND ASSEMBLY (SQ. FT.) _______________________________________________________

ACREAGE LEGALLY CONTROLLED

IN USE DEVELOPED TOTAL

LIST TYPES OF WORK NORMALLY SUBCONTRACTED

SHIPYARD:

MSC SHIP REPAIR FACILITY SURVEY (continued)

LIST ANY EQUIPMENT OR CAPABILITY NOT OTHERWISE DESCRIBED IN THIS FORM

REQUIRED SUBMITTALS TO ACCOMPANY THIS FORM:

1. PLOT PLAN OF YARD.

2. CERTIFIED DEPTH OF WATER PLOT

3. FOR EACH SHOP LISTED ON SHEET 4, A LIST OF MACHINE TOOLS AND

EQUIPMENT WHICH INDICATES THE CAPACITIES OF THE SHOP.

4. A GENERAL STATEMENT (INCLUE, NAME OF SHIP, DATES, AND

DOLLAR AMONT OF JOB) OF SHIP REPAPIR WORK WHICH HAS BEEN

ACCOMPLISHED BY THE APPLICANT.

5. LISTING OF OFFICIALS AND THE QUALIFICATIONS OF EACH FOR SHIP

REPAIR (INCLUDE AS A MINIMUM JOBS HELD, YEARS, HELD, ONE LINE

6. IF FACILITIES ARE LOCATED AT MORE THAN ONE LOCATION THEN

LIST EACH FACILITY AND ITS LOCATION.

7. POINT OF CONTACT FOR INFORMATION SUBMITTED IN THIS FORM

(NAME/TITLE/PHONE NUMBER).

NORMAL

SHIFTS

NORMAL

MAXIMUM

POTENTIAL MAXIMUM

CURRENT

CURRENT

EMPLOYMENT

MANAGEMENT, ADMINISTRATION

PROFESSIONAL ENGINEERING

PRODUCTION SKILLED

PRODUCTION UNSKILLED

NONPRODUCTION

TOTAL:

ARE YOU CERTIFIED AS A SMALL BUSINESS ? YES NO

NAME AND TITLE OF SENIOR SURVEYOR SIGNATURE DATE SIGNED