CDRL A002 DI-QCIC-81891 ATR.pdf
Data Item Description PDF 22 KB Posted
- Attached to
- Repair of a Ross Model LDM/DS-4 Mixer System
- Solicitation number
- N0016724Q0094
About this file
This document is a Data Item Description (DID) titled "ACCEPTANCE TEST REPORT (ATR)" that specifies the format and content requirements for a report documenting the results of qualification tests performed by a contractor to demonstrate that a system conforms to performance specifications, work authorization documents, or contract requirements.
The related federal contract opportunity is a combined synopsis/solicitation for the repair of a Ross Model LDM/DS-4 Mixer System. The solicitation is being issued under the authority of FAR 6.302-1(a)(2)(ii)(A) as the equipment is highly specialized, and it is likely that award to any other source would result in substantial duplication of cost to the Government. The Government intends to solicit and negotiate with Charles Ross and Son Company for this repair requirement. Interested parties may identify their interest by submitting a capabilities statement by March 29, 2024. This is not a request for competitive proposals, but the Government will consider all responses received by the due date when determining whether to conduct a competitive procurement.
View the file
Other versions and copies of DI-QCIC-81891
| File | Revision | Posted | Attached to |
|---|---|---|---|
| TAIILORED DID - A002 DI-QCIC-81891.pdf | Revision not stated | HEPA FILTER | |
| F1 26Q4003_DID-A002 DI-QCIC-81891.pdf | Revision not stated | 1500 CFM HEPA Filters | |
| F1 26Q4003_DID-A003 DI-QCIC-81891.pdf | Revision not stated | 1500 CFM HEPA Filters | |
| DI-QCIC-81891 Acceptance Test Report.pdf Same revision and size as this file | Revision not stated | Refurbishment and Factory Acceptance Testing of SEAMAC Winch | |
| A04. A003 DI-QCIC-81891 (Acceptance Test Report (ATR)).pdf | Revision not stated | IP Security Cameras | |
| CDRL A002 DI-QCIC-81891.pdf | Revision not stated | Underwater Motion Tracking System | |
| CDRL A002_DID DI-QCIC-81891.pdf Same revision and size as this file | Revision not stated | Submerged Acoustic Navigation System (SANS) Portable Beacon Support | |
| DI-QCIC-81891.pdf | Revision not stated | MAGTF Common Handheld - M67854-18-R-2023 | |
| DI-QCIC-81891.pdf | Revision not stated | MAGTF Common Handheld (MCH) |
Who attaches DI-QCIC-81891
Other files
| File | Type | Posted |
|---|---|---|
| Sole Source Justification_Redacted.pdf | ||
| N0016724Q0094 Mixer Repair Solicitation.pdf | ||
| CDRL A002 ATR.pdf | ||
| CDRL A001 DI-MGMT-80441D Property Report.pdf | ||
| CDRL A001 GFP Tracking Template.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATA ITEM DESCRIPTION
Title: ACCEPTANCE TEST REPORT (ATR) Number: DI-QCIC-81891 Approval Date: 20130118 AMSC Number: N9313 Limitation: N/A DTIC Applicable: N/A GIDEP Applicable: N/A Office of Primary Responsibility: AS/PMA251 Applicable Forms: N/A
Use/relationship:
The ATR contains the results of the qualification tests performed by the contractor to demonstrate that the system conforms to the performance specifications, work authorization document, or contract requirements.
This Data Item Description (DID) contains format, content, and intended use information for the data product resulting from the work task described in the Statement of Work (SOW).
Requirements:
1. Format. Contractor’s format is acceptable.
2. Content. The ATR shall contain the following:
a. Test article identification and full description of test specimens utilized, including any deviations for the configuration specified in the applicable test plan.
b. Date and location of test or evaluation.
c. The operator who conducted the test.
d. Results obtained, including specific identification and discussion of objectives demonstrated satisfactorily and those not demonstrated satisfactorily.
e. Contractor’s conclusions, corrective action anticipated, recommendation to correct. deficiencies, and suggested improvements based on evaluation of the test.
f. All analysis and supporting data.
g. All data sheets.
3. End of DI-QCIC-81891.