MILPORT INSPECTION 2024_Device List - Amendment 1.pdf
PDF 42 KB Posted
- Attached to
- OLCC Alarm Monitoring
- Solicitation number
- S-84500-00014073
- Issued by
- Multnomah County, Oregon
About this file
This document is a Device List for the Oregon Liquor and Cannabis Commission (OLCC) Milport warehouse location, detailing the fire and security system components across multiple zones and areas. The list comprehensively catalogs 36 devices including pull stations (5), smoke detectors (10), tamper switches (3), waterflow switches (3), heat detectors (2), and beam detectors (8), located in various areas such as warehouse man doors, office spaces, mezzanine, conference rooms, risers, and restrooms. Each device is assigned a specific address/zone number and precise location within the facility.
The device list appears to be part of a broader alarm monitoring and access control services contract, supporting the OLCC's comprehensive security infrastructure. The document provides a granular inventory of safety and security equipment, which will be critical for potential vendors bidding on the monitoring services contract to understand the existing system's configuration and complexity. The detailed breakdown allows for precise assessment of monitoring requirements across different building sections, including warehouse, office, and administrative areas, which will be essential for vendors preparing technical proposals and pricing strategies for the comprehensive security monitoring service.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| OLCC Milport Alarm Points.xlsx | XLSX spreadsheet | |
| OLCC Main Location Report~1.pdf | ||
| RFP Addendum 2~1.pdf | ||
| OLCC Milport Location Report~1.pdf | ||
| 06.25.19 Basic McLoughlin As-built Studio 3.pdf | ||
| HQ INSPECTION_Device List - Amendment 1.pdf | ||
| RFQ HQ-Warehouse Alarm Monitoring and Access Control Final.pdf | ||
| _Milport floor plans.pdf | ||
| OLCC Main Alarm Points.xlsx | XLSX spreadsheet | |
| ContractForServices ~2.docx | DOCX document | |
| RFP Addendum 1 Final.docx | DOCX document | |
| HQ Building Floor Plan Excluding Warehouse - Original.pdf | ||
| OLCC Fire Alarm Devices_Amendment 1.pdf | ||
| Mandatory Site Walk Vendor List 6-24-25.pdf |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Device Type address/ zone Location Obscuration Test
DEVICE LIST
5 SW Warehouse Man Door
5 Main Office Entry
6 NW Warehouse Man Door
6 North Center Warehouse Man Door
6 NE Watehouse Man Door
1 2nd Floor Mezzanine FACP
4 2nd Floor Mezzanine
4 2nd Floor Conference Room
2 1st Floor Bottom of Stairs
2 1st Floor Lobby
2 1st Floor Warehouse Breakroom by Lobby
2 1st Floor Office Server Room
2 1st Floor Office Area
2 1st Floor Office Area
2 1st Floor Office Area
2 1st Floor Office Area
10 North PIV
10 Center PIV
10 South PIV
9 North Riser
9 Center Riser
9 South Riser
3 1st Floor Restroom
3 1st Floor Restroom
7 South Side on East Wall
7 South Side on East Wall
7 South Side on East Wall
7 South Side on East Wall
8 North Side on East Wall
8 North Side on East Wall
8 North Side on East Wall
8 North Side on East Wall
Pull Station
Pull Station
Pull Station
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Smoke Detector
Tamper
Tamper
Tamper
Waterflow Switch
Waterflow Switch
Waterflow Switch
Heat Detector
Heat Detector
Beam Detector
Beam Detector
Beam Detector
Beam Detector
Beam Detector
Beam Detector
Beam Detector
Beam Detector