4) AL-1977-2097A_TS.pdf
PDF 1 MB Posted
- Solicitation number
- MG-11192026
- Issued by
-
Department of Energy
About this file
This is a Technical Specification document for the production of BENDB and BENDC dipole bending electromagnets for the ALS-U (Advanced Light Source Upgrade) storage ring at Lawrence Berkeley National Laboratory (LBNL). The specification establishes build-to-print subcontract requirements for manufacturing two types of gradient dipole magnets that bend and focus the electron beam. Document number AL-1977-2097, Revision A, was released on October 16, 2026, and applies to production activities conducted under the referenced subcontract.
The specification details technical requirements across three major assemblies: coils, yoke components, and final magnet assembly. For coils, the subcontractor must produce layer-wound hollow conductor main coils and trim coils using copper C10100-C10500 material, with vacuum epoxy impregnation and no internal splices. Material certificates with traceability and individual coil test reports documenting insulation resistance, inter-turn insulation, resistance, inductance, and cooling water flow are required. For yoke components, the subcontractor must machine AISI 1006 low carbon steel yoke halves and mirror poles, perform magnetic anneal heat treatment per LBNL-specified cycles in dry reducing atmosphere, and provide heat treatment logs with temperature profiles and serial number traceability. CoFe poles (ASTM A801 alloy 1) require magnetic anneal in dry argon atmosphere with ring samples produced from each material batch for testing. All yoke components require indelible marking with drawing numbers and serial numbers, plus CMM inspection reports documenting measured dimensions. Final magnet assemblies must undergo Factory Acceptance Testing including insulation resistance measurements at specified voltages, resistance measurements, hydrostatic leak testing at 1900 kPa, cooling water flow verification, and a two-hour power/temperature test with logging of voltages, temperatures, and water flow. Nominal design parameters for BENDB include 0.5135 m effective dipole length, 3.6457° bend angle, and -0.8266 T dipole field; BENDC specifications are similar with slightly different bend angle and field values, as listed in Tables 4-1 and 4-2.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 9) Rep Cert BENDB and BENDC.docx | DOCX document | |
| 2) Sample SubK Rev. 1- RFP MG-11182026.pdf | ||
| AL-1977-2102A.pdf | ||
| 1) RFP-BVSS BENDB and BENDC Rev. 1.pdf | ||
| AL-1925-6318A.pdf | ||
| 7) Past Performance Reference Form B.docx | DOCX document | |
| 5) GP-Commercial Supplies and Services.pdf | ||
| AL-1925-6317A.pdf | ||
| 8) AL-1208-0209C.pdf | ||
| 3) AL-1977-2101B_SOW.pdf | ||
| 6) GP-Commercial Foreign.pdf | ||
| AL-1477-4120N.pdf | ||
| AL-1479-9548N.pdf | ||
| 10) Price Proposal Schedule A RFP MG-11182026.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL SPECIFICATION FOR THE ALS-U STORAGE RING BENDB AND
BENDC MAGNETS
RELEASE DATE : 2026-10-16
AUTHOR:
DOCUMENT NUMBER: AL-1977-2097 REVISION: A
DOCUMENT STATUS: RELEASED
DOCUMENT TYPE: SPECIFICATION
CATEGORY CODE: AL0511
O ffi ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
Downloaded by: Martha Gamarano Grausz at October 22, 2026 09:31:03
AL-1977-2097 REV.A Doc.Status:RELEASED Page 2 of 12
TABLE OF CONTENTS
1 Revision History 2 2 Approvals 3 3 Abbreviations and Acronyms 3 4 Introduction 3 5 Coils 6
5.1 Materials 6
5.2 Manufacturing Procedures 6
5.3 Test Reports 7
6 Yoke 8
6.1 Low carbon steel parts 8
6.2 CoFe Poles 10
6.3 Inspection 11
7 Magnet Assembly 11
7.1 Factory Acceptance Test Reports 11
8 Applicable Documents 13
1 REVISION HISTORY
Rev. CM Number Description of Change
A Original Release
2 APPROVALS
The following individual(s) shall review this document:
Reviewer Project Role
Advanced Light Source
Lawrence Berkeley National Laboratory
All officially released LBNL documents are watermarked and contain LBNL Document Control
Center release information in the lower-left corner of the document's pages
Printed hard copies of this document are for reference only.
ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 3 of 12
The following individual(s) reviewed this document:
Reviewed by: MAJOHANSSON,MLERCHE,MVICKERS
The following individual(s) shall approve this document:
Approver Project Role
The following individual(s) approved this document:
Approved by: MLEITNER,SOPRESTEMON,OOMOLAYO,CASWENSON
3 ABBREVIATIONS AND ACRONYMS
ALS Advanced Light Source
ALS-U Advanced Light Source Upgrade
BENDB Configuration “B” Dipole Bending Electromagnet
BENDC Configuration “C” Dipole Bending Electromagnet
CMM Coordinate Measurement Machine
COTS Commercial off-the-shelf
CoFe Cobalt Iron
FAT Factory Acceptance Test
ID Identification
LBNL Lawrence Berkeley National Laboratory
4 INTRODUCTION
This specification document provides the technical requirements for the production of the
BENDB and BENDC dipole magnets for the ALS-U storage ring under a build-to-print
Subcontract.
The BENDB and BENDC magnet types are gradient dipoles. Both magnet types bend, and focus the electron beam with a high quadrupole/dipole field ratio implemented through a design using mirror pole pieces (see Figure 4-1). These magnets can also be described as asymmetric quadrupole bending magnets. The two types are mechanically identical except for their poles
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 4 of 12 having different curvature, due to their nominal bend angles being slightly different. Key design parameters for the magnet types are listed for reference in Table 4-1 and Table 4-2.
The BENDB and BENDC magnets are to be produced according to this technical specification and the applicable drawings and documents listed in section 8.
Figure 4-1 3D CAD views of the BENDB and BENDC dipole magnet types.
Table 4-1 BENDB magnet design parameters.
ID # (S09-02-) Parameter Value Unit
001002 Effective Dipole Length 0.5135 m
001003 Effective Gradient Length 0.5000 m
001007 Bend Angle 3.6457 °
001017 Dipole Field -0.8266 T
001018 Gradient 47.09 T/m
Table 4-2 BENDC magnet design parameters.
002002 Effective Dipole Length 0.5133 m
002003 Effective Gradient Length 0.5000 m
002007 Bend Angle 3.7627 °
002017 Dipole Field -0.8535 T
002018 Gradient 47.07 T/m
5 COILS
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 5 of 12
The BENDB and BENDC magnets have main coils located on the upper and lower poles, and a trim coil located on the return yoke.
The main coils are layer-wound hollow conductor coils of tapered shape with different exit lead routings for the upper and lower coils.
The trim coil is a layer-wound coil of rectangular shape, consisting of two middle layers of hollow cooled conductor, and two inner winding, and outer winding layers of solid enameled conductor, with all six layers series connected.
The BENDB/C coil production drawings are identified in the drawing list (see section 8), with additional specifications listed in sections 5.1-5.3, below.
5.1 Materials
1. Materials and COTS parts to be used are specified in the coil drawings listed in section 5.
2. The coil hollow conductor material is indicated as copper C10100 in the drawings but grades C10100 through C10500 are acceptable. The material grade must be the same for all BENDB/C coils.
3. Material certificates must be provided for the full quantity of conductor material, and traceability to individual coils must be maintained.
4. The coil potting epoxy formula must be proposed by the Subcontractor, subject to
LBNL approval.
5.2 Manufacturing Procedures
1. The coil winding must be done without internal splices.
2. The coils must be potted in epoxy by vacuum impregnation.
3. Large volumes of pure un-reinforced epoxy in the finished coil are not allowed.
4. Each coil must be indelibly marked with the LBNL drawing number and serial number.
5.3 Test Reports
Test reports for each individual coil must be provided as part of the FAT report package for each magnet, containing the info and test results listed below. All results must be for tests performed on the finished coils.
1. LBNL drawing number, serial number and Subcontract number.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 6 of 12
2. Conductor material certificate ID
3. Epoxy product information
4. Inspection and Test Results:
a. Conductor size
b. Number of coil turns
c. Coil mechanical dimensions: interior length and width, exterior length and width, and cross section height.
d. Ground insulation resistance, DC 1 min at specified voltage
e. Inter-turn insulation
f. Resistance between coil terminals, corrected to 20°C.
g. Coil inductance
h. Cooling water flow for each circuit at the coil level
i. Visual inspection after all other testing is completed.
5. Subcontractor’s acceptance of all info and results, with signature and date.
Parameter specifications corresponding to the tests listed above are given in the coil drawings or in Table 5-1 and Table 5-2. Tests/measurements with no tolerances specified in the Table 5-1 and Table 5-2 result parameters are informative. LBNL may reject outlier results at their discretion.
Table 5-1 Functional parameter specifications for the BENDB/C main coils.
ID # (S09-02-) Parameter Value Unit
001325/002325 Insulation Resistance Testing Voltage 1200 V
001326/002326 Minimum Insulation Resistance 2 GΩ
001328/002328 Minimum Inter-Turn Insulation Testing Voltage 10 V/turn
001304/002304 Resistance per Coil 36.7 mΩ
001400/002400 Number of Water Circuits per Coil 2 -
001405/002405 Design Cooling Circuit Pressure Drop 448 kPa
001406/002406 Cooling Water Flow per Circuit 0.75 l/min
001329/002329 Main Coil Inductance 1117.7 µH
Table 5-2 Functional parameter specifications for the BENDB/C trim coils.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 7 of 12
001374/002374 Insulation Resistance Testing Voltage 1200 V
001375/002375 Minimum Insulation Resistance 2 GΩ
001377/002377 Minimum Inter-Turn Insulation Testing Voltage 10 V/turn
001354/002354 Resistance per Coil 137.8 mΩ
001420/002420 Number of Water Circuits per Coil 1 -
001425/002425 Design Cooling Circuit Pressure Drop 448 kPa
001426/002426 Cooling Water Flow per Circuit 0.84 l/min
001379/002379 Trim Coil Inductance 2861.5 µH
6 YOKE
Each of the BENDB and BENDC yokes consists of upper and lower yoke halves, two CoFe pole pieces, and upper and lower mirror pole pieces. The CoFe pole piece and mirror pole piece geometries are slightly different for BENDB and BENDC while the yoke halves (and all other parts) are mechanically the same for BENDB and BENDC. The applicable production drawings are identified in the drawing list (see section 8), with additional requirements listed in sections
6.1 –6.3 below.
6.1 Low carbon steel parts
6.1.1Material
1. The specified material for the upper and lower yoke halves and the mirror poles is solid AISI 1006 low carbon steel.
2. Material certificates incl. chemistry reports must be provided and traceability to individual yoke parts must be maintained.
6.1.2Heat Treatment
1. To ensure good magnetic properties, the upper and lower yoke half subassemblies and the mirror poles must undergo a magnetic anneal after rough machining. For the yoke halves, the magnetic anneal must be done after welding.
2. All final machining operations, the installation of inserts, etc., must occur after magnetic anneal.
3. The threaded rods are to be removed from the yoke halves after positioning in the heat treatment furnace, and replaced and torqued after annealing.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 8 of 12
4. The anneal cycle listed in Table 6-1 is specified by LBNL for AISI 1006 steel to achieve acceptable magnetic properties. Note that this heat treatment process must be performed in a dry reducing atmosphere.
5. Heat treatment logs (the standard process traveler), must be provided containing the following info and results:
a. The atmosphere used.
b. The heat treatment time-temperature profile used in the furnace (by zone if applicable).
c. Logged temperature vs time (plot preferred), with sensor locations identified.
d. Serial numbers of individual yoke parts per heat treatment run.
Table 6-1 LBNL specified heat treatment for AISI 1006 steel yoke components
Activity Time [h]
Place yoke components in an oven which is at any temperature below 50 °C n/a
Heat oven at ≤ 220°C/hour up to 660°C 3
Hold at 660°C ±10°C 4
Heat oven from 660⁰C to 770°C at ≤55°C/hour 2
Hold at 770°C ±10°C to reach soak temperature 4
Hold at 770°C ±10°C for one more hour 1
Leave yoke components in oven; cool oven at ≤90°C /hour down to ≤500 ⁰C 3
Leave yoke components in oven, cool oven at ≤120°C /hour down to a maximum temperature 260⁰C
Remove yoke components from oven and air cool down to room temp n/a
6.2 CoFe Poles
6.2.1Material
1. The specified material for the poles is solid ASTM A801 alloy 1 (UNS R30005)
CoFe.
2. Traceability from CoFe blank material batch and serial numbers to finished pole piece serial numbers must be maintained.
3. Ring samples from the same material batches as the blanks must be produced
4. All ring samples must undergo heat treatment (see below) together with pole pieces of the same material batch.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 9 of 12
5. One ring sample per heat treatment run and material batch must be delivered to a testing laboratory of LBNL’s choosing. The remainder of ring samples must be delivered to LBNL.
6. Traceability of ring sample ID’s through heat treatment to delivery must be maintained.
6.2.2Heat Treatment
1. To ensure good magnetic properties, the CoFe pole pieces must undergo a magnetic anneal after rough machining.
2. Installation of bushings on the pole pieces must occur after magnetic anneal.
3. The anneal cycle listed in Table 6-2 is specified by LBNL for the CoFe material to achieve acceptable magnetic properties. Note that this heat treatment process must be performed in a dry Argon atmosphere of purity 0.9999 or greater.
4. Each heat treatment run must include ≥ 1 ring sample of same material batch(es) as the pole pieces.
5. Heat treatment logs (the standard process traveler), must be provided containing the following info and results:
a. The atmosphere used.
b. The heat treatment time-temperature profile used in the furnace (by zone if applicable).
c. Logged workpiece temperature vs time (plot preferred), with sensor locations identified.
d. Serial numbers of individual pole parts and ring sample(s) per heat treatment run.
e. Photo documentation of loaded oven before and after run.
Table 6-2 LBNL specified heat treatment for CoFe pole pieces
Activity Time [h]
Place pole pieces in an oven which is at any temperature below 100 °C n/a
Heat oven at 4-10 °C/min to a set point of 865°C. Oven temperature must never exceed
875°C.
≤ 3
Subcontracted directly by LBNL for measurement of ring sample magnetic properties.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 10 of 12
Activity Time [h]
Hold at soak temperature for 10 h. The soak temperature is the stable asymptotic temperature that the pole pieces reach ±2°C. The magnetic anneal/soak time clock starts when work piece temperature reaches 863°C.
Leave pole pieces in oven; cool oven at 85-100°C /hour down to ≤500 ⁰C ≤ 4
Leave pole pieces in oven, cool oven down to a maximum temperature 150⁰C ~3
Remove pole pieces from oven and air cool down to room temp n/a
6.3 Inspection
1. Each of the upper and lower yoke half subassemblies and mirror poles must be indelibly marked with the LBNL drawing number and serial number.
2. CMM inspection reports for each individual upper and lower yoke, mirror pole and upper and lower yoke assembly must be must be provided as part of the FAT report package for each magnet, containing measured results for dimensions noted as “to be measured and recorded” in the LBNL drawings.
7 MAGNET ASSEMBLY
The BENDB and BENDC magnets must be fully assembled according to the section 8 drawings, and tested/inspected as indicated in section 7.1 below.
7.1 Factory Acceptance Test Reports
A test report must be provided for each magnet assembly, containing results of tests performed on the assembled magnet, and references to documentation of constituent parts as listed below.
1. LBNL drawing number, serial number, and Subcontract number.
2. Yoke part serial numbers for each assembly location with corresponding inspection reports, material certificates, and heat treatment logs identified.
3. Coil serial numbers for each assembly location with corresponding test reports identified.
4. Mechanical dimensions, fully assembled:
a. Pole flat gaps between closest points on pole profiles
5. Insulation resistance:
Nom. 18 mm and 12.68 mm, see AL-1477-4120 and AL-1479-9548.
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 11 of 12
a. Between main coil terminals, and yoke
b. Between trim coil terminals, and yoke
c. Between main coil, and trim coil terminals
d. Between main coil terminals, and all thermal switch terminals
e. Between trim coil terminals, and all thermal switch terminals
f. Between all thermal switch terminals, and yoke
6. Resistance, corrected to 20°C:
a. Between main coil terminals
b. Between trim coil terminals
7. Cooling circuit hydrostatic leak test
8. Cooling water flow
9. Power/Temperature Test: Magnet powered with main coils at nominal current, and with the trim coil circuit at max current with a nominal cooling water pressure drop for 2 h, with magnet main coil and trim coil voltages, water inlet, water outlets, coil surfaces, pole and ambient temperatures logged.
10.Visual inspection after all other testing is completed.
11. Subcontractor’s acceptance of all info and results, with signature and date.
Parameter specifications corresponding to the tests listed above for the assembled magnets are given in Table 7-1. Tests/measurements with no tolerances specified in the Table 7-1 result parameters are informative. LBNL may reject outlier results at their discretion.
Table 7-1 Functional parameter specifications for the BENDB/C magnets.
ID # (S09-02-) Parameter Value Unit
001325/002325 Insulation Resist. Test Voltage – Main Coil Circuit 1200 V
001378/002378 Insulation Resist. Test Voltage – Trim Coil Circuit 600 V
001463/002463 Insulation Resist. Test Voltage - Thermal Switches 300 V
001326/002326 Minimum Insulation Resistance 2 GΩ
001304/002304 Main Coil Circuit Resistance 73.5 mΩ
001354/002354 Trim Coil Resistance 137.8 mΩ
001412, 001432, 002412, 002432 Cooling Circuit Hydrostatic Leak Test Pressure 1900 kPa
001405/002405 Design Cooling Circuit Pressure Drop 448 kPa
001409, 001426, 002409, 002426 Cooling Water Flow 3.84 l/min
001301 BENDB Main Coil Nominal Operating Current 182.8 A
001302 BENDB Main Coil Voltage at Nom. Current 13.43 V
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
AL-1977-2097 REV.A Doc.Status:RELEASED Page 12 of 12
001355 BENDB Trim Coil Maximum Operating Current ±26.93 A
001356 BENDB Trim Coil Voltage at Max. Current ±3.71 V
001408 BENDB Main Coils Water Temp. Rise at Nom. Current 11.8 °C
001428 BENDB Trim Coils Water Temp. Rise at Max. Current 0.4 °C
002301 BENDC Main Coil Nominal Operating Current 184.44 A
002302 BENDC Main Coil Voltage at Nom. Current 13.55 V
002355 BENDC Trim Coil Maximum Operating Current ±28.91 A
002356 BENDC Trim Coil Voltage at Max. Current ±3.98 V
002408 BENDC Main Coils Water Temp. Rise at Nom. Current 12.0 °C
002428 BENDC Trim Coils Water Temp. Rise at Max. Current 0.5 °C
8 APPLICABLE DOCUMENTS
This section identifies applicable documents that are considered to be a part of this document.
All information contained in an applicable document must be valid to the full extent, unless specifically noted within this document. Applicable documents shall be obtained from the LBNL
Document Control Center (DCC) by LBNL and provided as needed.
Document Number Title
AL-1977-2101
Statement of Work for the ALS-U Storage Ring BENDB and BENDC Magnets
AL-1477-4120 BENDB-DIPOLE MAGNET-SR (top level ass’y drawing)
AL-1479-9548 BENDC, DIPOLE MAGNET-SR (top level ass’y drawing)
AL-1977-2102
Drawing List for the SR BENDB and BENDC Dipole
Magnets
All officially released LBNL documents are watermarked and contain LBNL Document Control ci al ly R el ea se d
To th e
LB
N L
D oc um en t C on tr ol
C en te r
Re le as ed
: O ct ob er
6t h, D C
C A ut h
K ey
: X
SM
ZL
4K
| 1REVISION HISTORY |
| 2APPROVALS |
| 3ABBREVIATIONS AND ACRONYMS |
| 4INTRODUCTION |
| 5COILS |
| 5.1Materials |
| 5.2Manufacturing Procedures |
| 5.3Test Reports |
| 6YOKE |
| 6.1Low carbon steel parts |
| 6.1.1Material |
| 6.1.2Heat Treatment |
| 6.2CoFe Poles |
| 6.2.1Material |
| 6.2.2Heat Treatment |
6.3Inspection
| 7MAGNET ASSEMBLY |
| 7.1Factory Acceptance Test Reports |
8APPLICABLE DOCUMENTS
File details come from the government source that posted it. Updated .