This document is an Acceptance Criteria List (ACL) for the SR PTL vacuum chambers as part of the Advanced Light Source Upgrade (ALS-U) project at the Lawrence Berkeley National Laboratory (LBNL).

The ACL outlines the detailed acceptance criteria and inspection procedures for the SR PTL vacuum chambers, including visual, mechanical, magnetic permeability, vacuum, and shipping inspections. It specifies requirements such as surface finish, dimensional tolerances, leak rates, pressure testing, and documentation to be provided. The ACL must be completed for each vacuum chamber before acceptance. This ACL is the authorizing document referenced in the LBNL ALS-U Quality Assurance Plan.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Advanced Light Source Upgrade Project Lawrence Berkeley National Laboratory

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

Printed hard copies of this document are for reference only.

SR PTL Vacuum Chamber ACL

Release Date: May 14 2024 10:44:54 AM PDT

Document Number: AL-1708-1515 Revision: A

Document Status: Released

Document Type: ACCEPTANCE CRITERIA LIST (ACL)

Category Code: AL7426

O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15

AL-1708-1515 Rev. A Doc. Status: Released Page 2 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

TABLE OF CONTENTS

1 Revision History

2 Approvals

3 Abbreviations and Acronyms

4 Authorizing Document

5 Scope

6 Acceptance Criteria Listing Form

6.1 Visual Inspection

6.1 Mechanical Inspection

6.2 Magnetic permeability Inspection

6.3 Vacuum Inspection

6.4 Mechanical Inspection

6.5 Shipping inspection

6.6 Documentation

6.7 Observations / Comments

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 3 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

1 REVISION HISTORY

Rev. CM Number Description of Change A Baseline

2 APPROVALS

The following individual(s) shall approve this document:

Approver Project Role Jiani Niu Project QA manager Olusola Omolayo Vacuum CAM Windchill Approved / Concurred By jianiniu,oomolayo

3 ABBREVIATIONS AND ACRONYMS

ALS-U Advanced Light Source Upgrade SR Storage Ring HE Helium HPN2 High purity Nitrogen PTL Photon Transfer Line QA Quality Assurance

4 AUTHORIZING DOCUMENT

LBNL QA Plan PUB 3111: https://commons.lbl.gov/display/rpm2/Quality+Assurance+Policy

LBNL ALS-U Quality Assurance Plan, AL-1024-3173, https://dcc.lbl.gov/download.php?filename=AL-

1024-3173A.pdf

5 SCOPE

This document describes the acceptance criteria for SR PTL vacuum chambers. This document must be filled out for each SR PTL vacuum chamber.

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P https://commons.lbl.gov/display/rpm2/Quality+Assurance+Policy

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6 ACCEPTANCE CRITERIA LISTING FORM

Level of Care : ☐ Very High ☐ High ☐ Medium ☐ Low

Prepared by: Group:

Email: Location:

Phone: Date:

Part Name: Quantity:

Part Number: S/N (if applicable)

NCR Reviewers

Additional Remarks:

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 5 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.1 Visual Inspection

Verification and Testing Requirements

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

1.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

No visual damage on the outside of the vacuum chamber

NCR #: PASS ☐ FAIL ☐

N/A ☐

INITIALS DATE

2.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

LBNL Part and serial number are inscribed on chamber

3.

3155_SR PTL

Vacuum

Chamber ESD

Flange knife-edges are completely smooth and interruption-free when examined by lightly running an ethanol-wetted rubber cleanroom gloved finger around them.

4.

3155_SR PTL

Vacuum

Chamber ESD

Cleanroom wipes wetted with electronic grade ethanol do not yield debris or particles, or discoloration of the wipes

5.

3155_SR PTL

Vacuum

Chamber ESD

Presence of all fitting for cooling channel on the vacuum chamber ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 6 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

6.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

Threaded holes inspected with an electronic grade alcohol-soaked cleanroom swab do not yield particles or discoloration.

7.

3155_SR PTL

Vacuum

Chamber ESD

Presence of Pin (Round and Diamond) when required

8.

3155_SR PTL

Vacuum

Chamber ESD

No deformed or punched heater groove all around the vacuum chamber

9.

3155_SR PTL

Vacuum

Chamber ESD

Presence of fiducial nests on the chamber ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 7 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.1 Mechanical Inspection

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

11.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

CMM measurement verification before bakeout:

Tolerancing of agreed dimension are verified.

6.2 Magnetic permeability Inspection

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

10.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

Magnetic permeability:

Base material < 1.01

Weld joint < 1.04 ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 8 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.3 Vacuum Inspection

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

12.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

RGA scan:

Check all RGA scans reach the required criteria:

o With the chamber baked and at room temperature, the Sum of all peaks higher than Mass

44 shall be lower than

1/1,000th of total pressure o Partial pressure of Mass 18 shall be less than Mass 2 o Partial pressure of Mass 69 shall be less than 1/2,000th of total pressure o Partial pressure of Mass 14 shall be less than Mass 18.

NCR #:

PASS ☐ FAIL ☐

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

13.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

Final He Leak Test:

The chamber was pumped down below 1.0x10-4 Torr before leak checking

Verify that the maximum leak rate is below 1x10-10 torr-liters/sec

NCR #:

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 9 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.4 Mechanical Inspection

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

16.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

CMM measurement verification

After bakeout:

Tolerancing of agreed dimension are verified.

NCR #:

17.

3155_SR PTL

Vacuum

Chamber ESD

Pressure test:

Pressure: 120 Psi

Duration: 10 min

NCR #:

6.5 Shipping inspection

ITEM

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

18.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

HPN2 backfill:

The chamber shall be filled with HPN2 at or near atmospheric pressure

The chamber is shipped in sealed condition

NCR #:

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 10 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.6 Documentation

ITE

M

NO.

REQ ID /

DCC doc #

CHARACTERISTIC OR TEST TO BE

CONDUCTED, VERIFIED or

WITNESSED

VERIFYING

VENDOR

ENTITY

NonConformance

Report # if NCR exists

PASS / FAIL

DATE

VERIFICATION REPORT/

INSPECTION DATA

19.

AL-1705-

3155_SR PTL

Vacuum

Chamber ESD

Documentations:

All documentation related to the vacuum chamber are provided such as :

He leak test report

CMM measurement report

Certification of conformance

Etc…

NCR #:

ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

AL-1708-1515 Rev. A Doc. Status: Released Page 11 of 11

All officially released LBNL documents are watermarked and contain LBNL Document Control Center release information in the lower-left corner of the document's pages.

6.7 Observations / Comments

Use the following table to make observations on the previous tests conducted if needed.

ITEM NO. Observation / Comments ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

Downloaded by: Mouda Tung at May 14, 2024 13:01:15O ffi ci al ly R el ea se d to th e

LB

N L

D oc um en t C on tr ol

C en te r

Re le as ed

: M ay

4t h, D C

C A ut h

K ey

: C

C

4P

File details come from the government source that posted it. Updated .