ME Cooler.freezer - floorplans .pdf
PDF 564 KB Posted
- Attached to
- RFQ- HVAC Service Agreement- Central Point
- Solicitation number
- S-25700-00016910
- Issued by
- Jackson County, Cheshire CDP, Oregon
About this file
This is a floor plan document for the Oregon State Police Central Point Area Command facility, specifically depicting the cooler and freezer areas. The document provides architectural layouts and spatial configurations for the refrigeration units located within the facility, which is the subject of a five-year HVAC service agreement request for ongoing support and maintenance of the building's heating, ventilation, and air conditioning systems.
The floor plans serve as supporting documentation for the RFQ by illustrating the physical layout and dimensions of specialized climate-controlled spaces that require integration with the facility's HVAC system. This technical reference material would be essential for HVAC vendors to understand the facility's infrastructure, assess maintenance requirements, and develop accurate service proposals that account for the cooler and freezer specifications and their relationship to the broader building systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ASSET INVENTORY- MFR recommended PM schedule.pdf | ||
| Mechanical Systems - floorplans .pdf | ||
| Sample ContractForServices .pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
P T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
XE
X9
X9
X10
X10
X11
X11
X12
X12
XD
XC
X-RAY ROOM
M118
LAB
M115
ADMIN/COPY/FILE
ROOM
M113
ADMIN OFC
M112
TECH OFFICE
POD
M111
CONFERENCE
ROOM
M106
PATHOLOGIST
OFC
M105
PATHOLOGIST
OFC
M104
RECEIVING
VESTIBULE
M100
JAN/SUPPLY
M107
TOILET
M108
TOILET
M109
AUTOPSY
SUPPLIES /
CHEMICAL
STORAGE
M116
LAUNDRY/DRYING
M117
AUTOPSY
RECEPTION
M101
COOLER
M102
ISO-FREEZER
M102.1
ISO-AUTOPSY
M103.2
AUTOPSY
SUITE
M103
OFFICE
M103.1
STORAGE /
FLEX OFFICE
S122
UNISEX
LOCKER ROOM
M120
UNISEX
LOCKER ROOM
M119
AS-01
AS-01
AS-01
AS-01
SL-01
SL-01
SL-01
SL-01
AS-01
AS-01
AS-01
AS-01
HAC-01
HAC-01
HAC-01
XR-01
XRC-01
ATC-01
ATC-01
ABC-01
ABC-01
ABC-01
ATC-01
ATC-01
ABC-01
HAC-01
ESEW-01
FS-01
BCC-01
ME OPEN
CIRCULATION
M114
VESTIBULE
M110
VESTIBULE
M121
VESTIBULE
S120
5A 4A 3A 2A
BA
CA
DA
EA
E. 6. 26 A14.3
2A
1A
AA
LKR-3
LKR-3
LKR-3
LKR-3
LKR-3
LKR-3
SALLY PORT
M100.1
A14.3
4C
BL-01
FRSS-01
FRSS-01
FRSS-01
FRSS-01
FRSS-01
FRSS-01
FRSS-01
FRSS-01
BCC-01
HCL-01
D L R
G ro u p
REVISIONS
A B C D E F
/1
/2
:1
:5
A
M
A u to d e s k D o c s /7
-2
-0
O
S P
C e n tr a l P o in t/
-2
-0
O
S P
C e n tr a l P o in t_ A
R
.r v t
74-22115-00
06-16-2023
C E
N T
R A
L P
O
IN
T O
F F
IC
E
R E
N O
V A
T
IO
N
A D
D
IT
IO
N
100%
CONSTRUCTION
DOCUMENTS
ENLARGED
FLOOR PLANS -
MEDICAL
EXAMINER
EQUIPMENT PLAN
A2.5-P2
R o g u e V a lle y H w y C e n tr a l P o in t, O
R
O R
E G
O N
S T
A T
E P
O L
IC
E
C
O N
T R
A C
T
P O
-2
-0
SCALE: 1/4" = 1'-0"A2.5-P2
1 ENLARGED PLAN - MEDICAL EXAMINER EQUIPMENT
RFI 386 1-28-25
PR-03 4-14-25
PR-03
noahpr Navigation Buttons
INDEX PAGE
noahpr Navigation Buttons next > noahpr Text Box < back
GageEk
RFI
GageEk Group
RFI 0537
GageEk Rectangle
GageEk Rectangle
File details come from the government source that posted it. Updated .