MD SP NASA 2(1)_Bridge_Insp_Rpt_2022.pdf

PDF 1 MB Posted

Attached to
NASA Goddard Space Flight Center Federal contract opportunity
Solicitation number
693C73-24-B-000003
Issued by
Department of Transportation Federal Highway Administration

About this file

This bridge inspection report details the condition of the NASA Access Bridge located at the Goddard Space Flight Center in Maryland. The 381-foot long steel girder bridge carries the NASA access road over the Baltimore-Washington Parkway and connects to the employee entrance. The biennial routine inspection found damage to the south exterior beam in span 2 after an impact, requiring the bridge's closure. Maintenance and rehabilitation needs are identified over the next five years, including replacement of expansion bearings, cleaning and painting structural steel, replacing deck joints, and removing unsound concrete from piers. Estimated costs total over $4 million. The related federal contract opportunity is a solicitation from the Department of Transportation Federal Highway Administration seeking bridge inspection and rehabilitation services for the damaged NASA Access Bridge.

View the file

Other files for this federal contract opportunity

Other files attached to NASA Goddard Space Flight Center, newest first.
File Type Posted
Results of Bid Opening - MD SP NASA 2(1).pdf PDF
Amendment 0001 - MD SP NASA 2(1).pdf PDF
IFB Solicitation - MD SP NASA 2(1).pdf PDF
Plans - MD SP NASA 2(1).pdf PDF
FP14_Eng.pdf PDF
Categorical Exclusion Form (NEPA).pdf PDF
MD SP NASA 2(1)_Bridge_Insp_Rpt_2021.pdf PDF
VETS-4212 Form.pdf PDF
ADV_Bidders Qualifications Form.doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

NASA ACCESS BRIDGE

NASA ACCESS ROAD OVER BALTIMORE-WASHINGTON PARKWAY

GODDARD SPACE FLIGHT CENTER

LOOKING EAST

STRUCTURE NO. 2170-001P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 4/26/2022

DAMAGE TO SOUTH EXTERIOR BEAM IN SPAN #2

Report prepared by:

Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 2170-001P

NASA ACCESS BRIDGE INSPECTION DATE : 04/26/2022

226 PRIORITY OF IMPROVEMENT E

A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

Item No.

Maintenance Recommendations

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT UNIT

COST

PRELIM.

COST

ESTIMATE

60.11

SEAL JOINTS ALONG SLOPE PROTECTION AT ABUTMENTS

AND ALONG PAVED WATERWAYS AT WINGWALLS TO HELP

PREVENT WATER INTRUSION.

1 LS 10000 10000

59.11

REMOVE VEGETATION GROWTH FROM PAVED

WATERWAYS AND TREES ENCROACHING ON GIRDERS. 1 LS 3000 3000

58.2,58.7, 222.9

PERIODICALLY REMOVE DEBRIS AND VEGETATION

GROWTH FROM DECK EXPANSION JOINTS, ALONG

CURBLINES AND APPROACH PARAPETS.

1 LS 2000 2000

PRELIM. MAINTENANCE TOTAL : 15000

Item No.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST

PRELIM. COST ESTIMATES

REHAB RECONSTR

59.1 REPLACE EXPANSION BEARINGS AND REPAIR

BEARING SEATS AND BOLSTERS AS

NECESSARY.

1 LS 1800000 1800000

59.1 CLEAN, PAINT, AND LUBRICATE FIXED

BEARINGS AND REPAIR BEARING SEATS AND

BOLSTERS AS REQUIRED.

1 LS 320000 320000

59.2 CLEAN AND SPOT PAINT STRUCTURAL STEEL

AS NEEDED. 1 LS 15000 15000

58.2 REPLACE COMPRESSION SEALS IN DECK

JOINTS OVER PIERS #1 AND #2. 1 LS 15000 15000

58.2 REPAIR BROKEN ANCHOR STUD TO DECK

ARMORING WELDS. 1 LS 3000 3000

60.13 REMOVE UNSOUND CONCRETE FROM PIERS

AS NECESSARY AND PLACE NEW CONCRETE

TO ORIGINAL DIMENSIONS.

1 LS 150000 150000

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 2170-001P

NASA ACCESS BRIDGE INSPECTION DATE : 04/26/2022

PRIORITY OF IMPROVEMENT226

A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

E

222.3 REPLACE APPROACH GUARDRAIL.

1 LS 50000 50000

222.4 MILL AND OVERLAY APPROACHES AND INSTALL

ROADWAY STRIPING ALONG DECK SURFACE

AND APPROACHES.

1 LS 35000 35000

CONTRACT COSTS FOR MOBILIZATION,

TRAFFIC CONTROL, DESIGN, AND

CONSTRUCTION ENGINEERING.

1 LS 1700000 1700000

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : 4088000

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL :

PRELIM. REHABILITATION TOTAL :

PRELIM. RECONSTRUCTION TOTAL : ..

TOTAL ITEMIZED COSTS:

15000

4088000

PRELIMINARY ESTIMATE TOTAL * :

4103000

4103000

(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)

Remarks : Cost estimates are based on data from similar projects.

STRUCTURE LOAD RATING STRUCTURE NO. 2170-001P

NASA ACCESS BRIDGE INSPECTION DATE: 04/26/2022

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 26 24 44 40

HS 40 36 67 61

TYPE 3 35 32 58 53

TYPE 3S2 52 47 87 79

TYPE 3-3 68 62 114 103

DESIGN LOADING: 5 - HS 20

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

X ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION: 08/01/2017

LOAD RATING CONTROLLED BY: SPAN #1 INTERIOR GIRDER MOMENT

REMARKS: SEE BRIDGE FILE FOR LOAD RATING CALCULATIONS.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 2170-001P

STRUCTURE IDENTIFICATION

(201) PARK: GODDARD SPACE FLIGHT CENTER

(202) STRUCTURE NAME:..............NASA ACCESS BRIDGE

(203) STRUCTURE KIND:............... 1 - BRIDGE

(204) STRUCTURE NUMBER:.........2170-001 P

(205) NPS REGION:

(206) ROUTE CODE NUMBER:

(207) ROAD SECTION NO:

(208) NPS ROAD CLASS:............... 1 - PRINCIPAL PARK ROAD

(209) WITHIN NPS BNDRY?:.......... Yes

(210) OPERATING UNIT:.................NASA

(211) PROJECT NO(S):................... 1D16,E13

(212) DRAWING NUMBERS:...........NONE

(21) MAINTAINED BY:......................75 - NASA

(22) OWNER:................................... 75 - NASA

(1) STATE:

(2) STATE HWY. AGENCY DIST:

(3) COUNTY CODE:

(4) CITY / PLACE CODE:

(5) INVENTORY ROUTE:

(6) FEATURES INTERSECTED:

(7) FACILITY CARRIED:

(8) STATE STRUCTURE NO:

(9) LOCATION:

(10) INV. RTE. - MIN. VERT. CLR:

(11) MILE POINT:

(27) YEAR BUILT:

(106) YEAR RECONSTRUCTED:

(20) TOLL:

(37) HISTORIC DESIGNATION:

243 - MARYLAND

24033 PRINCE GEORGE'S

40435

1 6 6 00000 0

BALT MORE-WASHINGTON

PARKWAY

NASA ACCESS ROAD

2170001P0000000

Beltway to Exit 22 - Route 295 (B-W Parkway) North. 3nd exit (employee entrance) for NASA Goddard Space Flight Center. U-Turn to bridge.

99.99 FT ( 99.99 M)

.00 (KM PT: 0 )

3 - ON FREE ROAD

5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL:..........3 - STEEL (44A) APPR. STR. MATERIAL:............ 0 - Other

(43B) MAIN STR. TYPE:.................. 02 - STRINGER/MULTI-BEAM OR (44B) APPR. STR. TYPE:.................... 00 - OTHER

GIRDER

(45) NO. OF MAIN SPANS:..............006 (46) NO OF APPROACH SPANS:

(48) MAX. SPAN LENGTH:..............86.3 FT ( 26.3 M)

(49) STRUCTURE LENGTH:........... 381. FT ( 116.1 M) (108) WEAR SURFACE/PROTECT SYSTEM:

(216A) ABUTMENT #1 FDN:........... 3 - SPREAD FOOTING ON PILES A) TYPE WEARING SURFACE:.. 0 - NONE

(216B) ABUTMENT #2 FDN:........... 3 - SPREAD FOOTING ON PILES B) TYPE MEMBRANE:................. 0 - NONE

(217A) PREDOM. PIER FDN:.......... 3 - SPREAD FOOTING ON PILES C) TYPE PROTECTION:.............. 0 - NONE

(217B) SECOND. PIER FDN:.......... 3 - SPREAD FOOTING ON PILES (218) IS SALT USED?.......................... YES

(107) DECK TYPE:.......................... 1 - CONCRETE CAST-IN-PLACE

LOAD RATING AND POSTING

(31) DESIGN LOAD:.........................5 - HS 20 (41) LOAD RESTRICTION:.................. K - CLOSED

(66) INVENTORY RATING:..............0 TONS ( 0 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGAL

LOADS

(64) OPERATING RATING:..............0 TONS ( 0 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 04/26/2022 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N

(220) SPECIAL STUDY TYPE: 1 - DECK SURVEY INSP. EVERY MONTHS - LAST INSP:

(221) SPECIAL STUDY DATE: 06/01/1992 (B) UNDERWATER:..................... N

INSP. EVERY MONTHS - LAST INSP:

(C) SPECIAL INSPECTION:........ N

INSP. EVERY MONTHS - LAST INSP:

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 2170-001P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(16) LATITUDE:................................ 39° 00'20 50 " (51) CURB TO CURB WIDTH:............ 38.0 FT ( 11.6 M)

(17) LONGITUDE:............................ 76 51° '45 00 " (52) DECK WIDTH:.......................... 41.7 FT ( 12.7 M)

(19) DETOUR LENGTH:.................. 0 MI ( 0 KM) (32) APPR. ROADWAY WIDTH:...... 38.0 FT ( 11.6 M)

(28A) LANES ON STRUCT:.............02 (213) APPR. PAVEMENT WIDTH:... 38.0 FT ( 11.6 M)

(28B) LANES UNDER STRUCT:......04 LEFT SHOULDER:............... 0 0 FT ( 0 M)

(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 0 0 FT ( 0 M)

(42B) SERVICE UNDER:................. 6 - HIGHWAY - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN

(29) AVG DAILY TRAFFIC:..............10000 (34) SKEW ANGLE:......................... 16 °

(30) YEAR OF ADT:......................... 2020 (35) STRUCTURE FLARED:............ 0 - NO FLARE

(114) FUTURE ADT:.........................11000 (47) TOTAL HORIZ. CLEARANCE:.. 38 FT ( 11.6 M)

(115) YEAR OF FUTURE ADT:........2040 (50) SIDEWALKS

(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0 0 FT ( 0 M)

(38) NAVIGATION CONTROL:.........0 - NO NAVIGATION CONTROL ON RIGHT:.................................. 0 0 FT ( 0 M)

WATERWAY (BRIDGE PERMIT NOT

REQUIRED)

(39) VERTICAL CLEARANCE:.........0 FT ( 0 M) (214) BRIDGE RAIL TYPE

(40) HORIZ. CLEARANCE:..............0 FT ( 0 M) RAIL CONFIGURATION:...... 2 - MOUNTED ON PARAPET

(111) ABUT OR PIER PROT:........... MATERIAL:........................... 4 - STEEL

LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 1 - CONTINUOUS RAIL

(55) RIGHT:..............................9.80 FT ( 2.99 M) (215) BRIDGE RAIL HEIGHT:.......... 4 25 FT ( 1.3 M)

(56) LEFT:................................ 5.4 FT ( 1.6 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)

(54) MIN. VRT. UNDRCLRANCE:... 14.17 FT ( 4.32 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL:

(62) CULVERT:.................................N

(222) APPROACHES:

(223) RETAINING WALL:.................N

(36) TRAFFIC SAFETY FEAT: 1 1 1 1

(75A) TYPE OF WORK:................... 35 - REHABILITATION - DETERIORATION

(75B) WORK DONE BY:.................. 1 - WORK TO BE DONE BY CONTRACT

(76) IMPROVEMENT LENGTH:.......381.0 FT ( 116.1 M)

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:.................... 5 - SCOUR WITHIN LIMITS OF

FOOTING OR PILES

(225) PURPOSE OF IMPROVEMENT: 2 - REHAB/RECONSTRUCTION

(226) PRIORITY OF IMPROVEMENT: E - SPECIAL

(227) MAINTENANCE COST:

(228) REHAB / RECNSTR COST:

(229) CONSTRUCTION COST:

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

PREVIOUSLY INSPECTED AS STRUCTURE NO. 3230-012P. 2004 REHABILITATION INCLUDED DECK REPLACEMENT, REPAINTING OF STEEL SUPERSTRUCTURE, AND CONCRETE REPAIRS TO SUBSTRUCTURE. 2021-IMPACT DAMAGE TO SPAN #2. BRIDGE CLOSED BY NASA.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIGURATION INFORMATION:

Inspector: Zane Bailey Structure Number: 2170001P0000000

Inspection Date: 04/26/2022 Facility Carried: NASA ACCESS ROAD

Bridge Inspection Report

Pictures

PHOTO 3

Description CLOSED RAMP TO ACCESS NASA GODDARD FROM NORTHBOUND BW PARKWAY

PHOTO 4

Description CLOSED RAMP TO ACCESS NASA GODDARD FROM SOUTHBOUND BW PARKWAY

Bridge Inspection Report

Pictures

PHOTO 5

Description CLOSURE OF EAST ACCESS TO BRIDGE

PHOTO 6

Description PREVIOUSLY USED NASA EMPLOYEE ENTRANCE; NOTE CLOSED WITH DOUBLE GATES

Bridge Inspection Report

Pictures

PHOTO 7

Description GENERAL TOPSIDE VIEW OF SPAN #2

PHOTO 8

Description INTERIOR VIEW OF SOUTH EXTERIOR BEAM IN SPAN #2; NOTE BOTTOM FLANGE IS

UPWARDS APPROXIMATELY 8"

Bridge Inspection Report

Pictures

PHOTO 9

Description DAMAGE TO NORTH EXTERIOR GIRDER IN SPAN #2

File details come from the government source that posted it. Updated .