MBP Facility Buildings Overview.pdf

PDF 383 KB Posted

Attached to
472/23133. JBB; Marquette Brnch Prisn- Kitchen Cooler/Freezer
Solicitation number
RFP - 171 - 230000003071
Issued by
Delta County, Menominee City, Michigan

About this file

The document is a site plan for the Marquette Branch Prison, a correctional facility operated by the Michigan Department of Corrections. The site plan provides an overview of the facility's various buildings and yard areas, including an I.C. Store Addition, Central Tower, Steel Water Tank, Sallyport Checkstation, Greenhouse Cylinder Storage Shed, Guard Posts, Carport, Administration Buildings, Powerhouse, Food Service, Chapel, Dormitories, and Warehouses. The document includes a key plan and notes regarding the electrical work required for the facility.

The related state and local contract opportunity is for the Marquette Branch Prison Kitchen Cooler/Freezer project, which is located in Delta County and the city of Menominee, Michigan. The contract details are not provided in the document, but it is likely that the state of Michigan and the local jurisdictions are seeking bids for the construction or renovation of the kitchen cooler and freezer systems at the prison.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(ERT) BLDG. 12

I.C. STORE ADDITION

BLDG. 99

CENTRAL TOWER POST 9

BLDG. 32

STEEL WATER TANK

BLDG. 39

SALLYPORT CHECKSTATION

BLDG. 48

GREENHOUSE

CYLINDER STORAGE SHED

BLDG. 100

GUARD POST

# 3

SALLYPORT

BLDG.

GUARD POST

# 8

CARPORT

BLDG. 106

GUARD POST # 4

GUARD POST# 2

ORCHARD GUARD POST

BLDG. 36

TD

ANNEX

ADMINISTRATION

BROOKS CENTER

BLOCK B

BLOCK C

BLOCK D

BLOCK G

BLOCK F

BLOCK E

CENTRAL

KITCHEN

LEVEL V

CHAPEL

PROGRAMS

BUILDING

POWERHOUSE

FOOD

SERVICE

TD CHAPEL

N DORM

O DORM

TD PROPERTY

TD SCHOOL

MSI

QUARTERMASTER

P DORM

A-UNIT

WAREHOUSE

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

R O

B E

R T

C

H A

L L

R A

N

C A

R B

D

IR

E

C T

O R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

E a s t

K a la m a z o o A v e n u e

S u it e

K a la m a z o o

M ic h ig a n

-5

.3

.6

P H

O N

E

.3

.6

F A

X

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

E a s t

F u lt o n S tr e e t, S u it e

G ra n d R a p id s

M ic h ig a n

.4

.9

P H

O N

E

.4

.5

F A

X

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

M A

R Q

U E

T T

E F

A C

IL

IT

Y S

IT

E

P L A

N

-1

.9

E S

A U

G U

S T

P e rs o n a l E m e rg e n c y L o c a ti o n

S y s te m

M A

R Q

U E

T T

E B

R A

N C

H P

R

IS

O N

M a rq u e tt e

M I

F ile

N o

/2

.G A

G

S T

A T

E O

F M

IC

H

IG

A

N D

E P

A R

T M

E N

T O

F C

O R

R E

C T

IO

N

S

/2

.G

A G

/0

/2

MDOC - MARQUETTE

KEY PLAN

SCALE: NO SCALE

1/64" = 1'-0"

MARQUETTE FACILITY SITE PLAN

ISSUED FOR DATE

GENERAL ELECTRICAL NOTES

EXTERIOR ZONES

1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND

PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE REMOVED AND

NOT REPLACED.

2 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED

EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH EQUIPMENT,

ADJUST CIRCUIT SIZE AS REQUIRED.

3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.

4 ALL CONDUITS SHALL RUN AS NEAR TO DECK AS PERMITTED BY CODE. MOST

CONDUITS WILL BE EXPOSED AND SHALL BE RUN IN A NEAT MANNER.

MAINTAIN THE SAME SPACING WHEN CONDUITS ARE RUN TOGETHER.

5 WHEN CEILINGS ARE REMOVED ELECTRICAL CONTRACTOR SHALL PROPERLY

SUPPORT ALL CONDUIT AND LOW VOLTAGE WIRING AS REQUIRED PER NEC.

6 REMOVE CEILINGS AND GRID AS REQUIRED. REPLACE ANY DAMAGED

CEILINGS.

7 ALL CONDUITS SHALL BE EMT, COMPRESSION FITTING TYPE, WITH 2-HOLE

STRAPS 3" ON CENTER AND WITHIN 12" OF A JOINT OR JUNCTION BOX. ALL

JUNCTION BOXES SHALL HAVE NO KNOCK OUTS WHERE INDICATED IN

SPECIFICATIONS AND ALL FASTENERS AND BOLTS SHALL BE SECURITY TYPE

WITH A 2-HOLE STRAP.

8 CONTRACTOR IS RESPONSIBLE FOR PROVIDING SWITCHES AS NECESSARY,

LEVERAGING EXISTING FIBER INFRASTRUCTURE. CONTRACTOR IS

RESPONSIBLE FOR PROGRAMMING SYSTEM ON A NEW DEDICATED NETWORK.

1 B/C YARD

2 E/F YARD

3 D YARD

4 PROGRAMS YARD

5 SOUTH YARD

6 BROOKS CENTER YARD

7 CHAPEL YARD

8 CHAPEL BACK YARD (OB)

9 CENTRAL KITCHEN

10 PROGRAMS BACK YARD (OB)

11 NORTH YARD

12 MSI OB

13 PROPERTY OB

14 SCHOOL OB

15 FOOD SERVICE OB

16 MIDDLE YARD

17 O DORM

18 N DORM OB

19 SOUTH YARD

20 P DORM OB

21 WAREHOUSE OB

22 A-UNIT OB

SYMBOLS