Material List~1.pdf

PDF 99 KB Posted

Attached to
Construction & Abandon Deep Well CP Groundbeds
Solicitation number
UD-24-210
Issued by
California

About this file

This is a materials list and construction specification document for the City of Long Beach related to cathodic protection (CP) system upgrades. The project requires five primary upgrade components: installation of a new anode groundbed, relocation of an existing rectifier and cabinet, installation of an anode panel, extension of structure connections, and provision of new AC power infrastructure. The new anode groundbed requires 10 high-silicon cast iron anodes with HALAR cable, 10 anode centralizers, 180 bags of SC-3 backfill, 10 lengths of 2-inch PVC vent pipe, 8 lengths of 2-inch PVC solid pipe, and one flush traffic box with cast iron lid labeled "ANODE." The anode panel installation requires one 10-inch by 12-inch panel board with 10 circuits and 0.001 ohm shunts, plus 5 feet of #4 AWG THHN positive cable. The structure connection extension requires one flush traffic box labeled "CP TEST," 100 feet of #4 AWG HMWPE negative cable, one 3M splice kit with resin, and 4 lengths of 2-inch PVC solid pipe. New AC power installation requires 100 feet of AC power cable per city requirements and 6 lengths of 2-inch PVC solid pipe.

Prior to commencing work, contractors must obtain a City of Long Beach encroachment permit, well permit, temporary water hydrant permit, city electrical build permit, and must mark and call dig alerts at least 48 hours in advance. The rectifier and cabinet relocation requires materials as needed based on site-specific conditions. AC power cable specifications are to be determined by the electrical engineer and approved by both the City of Long Beach and the applicable power company, indicating that final power infrastructure requirements are subject to regulatory and utility approval.

View the file

Other files

File Type Posted
07.02.24 RFP Authorization Certification~1.pdf PDF
NOI CP12.pdf PDF
Mandatory Attachment B Equal Benefits Ordinance Form_Fillable~1.pdf PDF
CP Deep Well RFP~1.docx DOCX document
CP12 Maps~1.pdf PDF
CP12 TEST POINTS.pdf PDF
Addendum 1 UD24-210 DR KV.pdf PDF
Certification of Site Examination~1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CP 12 (SHEET 006)

MATERIALS LIST AND ITEMS NEEDED FOR CONSTRUCTION

The following permits will be required as a minimum to perform work:

City of Long Beach Encroachment Permit

Well Permit

Temporary Water Hydrant Permit

City of Long Beach Electrical Build Permit

Dig Alerts marked and called at least 48 hours in advance

The following provides a summary of materials needed for each upgrade step outlined in the previous section:

1. New Anode Groundbed

Quantity Item Notes

10 High-Silicon Cast Iron Anodes with #8 or #6 AWG HALAR Cable to be appropriate length

10 Anode Centralizer For 3-4” anodes

180 Bags of 50# SC-3 Backfill Loresco

10 2” PVC Vent Pipe 20-ft lengths each

8 2” PVC Solid Pipe 20-ft lengths each

1 Flush Traffic Box with Cast Iron Lid Lid labeled “ANODE”

2. Relocate Existing Rectifier and Cabinet

As needed

3. Anode Panel

1 10” x 12” panel board with (10) circuits 0.001 ohm shunts

5 Feet of #4 AWG THHN Positive Cable Colored Red

4. Extending Structure Connection

1 Flush Traffic Box with Cast Iron Lid Lid labeled “CP TEST”

100 Feet of #4 AWG HMWPE Negative Cable Colored Black

1 3M Splice Kit with Resin

4 2” PVC Solid Pipe 20-ft lengths each

5. New AC Power

100 AC Power Cable Per City Requirements for load*

6 2” PVC Solid Pipe 20-ft lengths each

*As specified by the electrical engineer, approved by the City and Power Company