UNCLASSIFIED
DRAFT: D400.12663.04.RUC_VS – May 2021 i
UNCLASSIFIED
Regional Unified Capabilities (R-UC)
Voice Services Solution
Architecture and Concept of Operations
USMC Release:
D400.12663.04.MCEN_RUC-VS
Version 1.1
17 May 2021
Marine Corps Systems Command
Network Communications Infrastructure
United States Marine Corps Portfolio Manager
DISTRIBUTION STATEMENT D: Distribution authorized to the Department of Defense (DoD) and U.S.
20 August 2020. Other requests shall be referred to Portfolio Manager, Network and Infrastructure, Marine Corps
Systems Command (MCSC), 2200 Lester Street, Quantico, VA 22134-6050.
WARNING: This document contains technical data whose export is restricted by the Arms Export Control Act
(Title 22, U.S.C., Sec 2751, et seq.) or the Export Administration Act of 1979 (Title 50, U.S.C., App. 2401 et seq.), as amended. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive (DoDD) 5230.25.
DESTRUCTION NOTICE: For Unclassified destroy by any method that will prevent disclosure of contents or reconstruction of the document.
ISTC Unified Capabilities Architecture and CONOPS
DRAFT: N65236-USMC-BTI-SEP-0001 V4.00 – 24 June 2019 ii
Unclassified / For Official Use Only
Program Executive Office Digital & Enterprise Services (PEO Digital)
Infrastructure Services, Transport and Communications (ISTC)
Marine Corps
Regional Unified Capabilities, Voice Services Solution –
Architecture and Concept of Operations (CONOPS)
Approved By:
Andrew Mittura
USMC APM-E
Infrastructure Services, Transport & Communications
PEO Digital Enterprise Services
Regional UC – Voice Services Solution Architecture and CONOPS
DRAFT: D400.12663.04.RUC_VS – May 2021 ii
Change History
The Change History identifies all changes incorporated into the updated version of this document after initial approval. The Regional Unified Capabilities (UC) – Voice Services (VS) Solution
Architecture and Concept of Operations (CONOPS) document is a configuration item and will be managed in accordance with the Network Communications Infrastructure (NCI)
Configuration Management Plan (CMP). Updates to this document that are related to any significant changes in the project will go through the Configuration Management (CM) process for approval.
The following table contains a record of changes made to this document. The NCI Lead Systems
Engineer (LSE) and supporting personnel are responsible for providing additional updates between versions to include risk status updates, new reviews accomplished, schedule updates, and any other activities as they are completed. The approval process is the same for all version updates.
Change History Log
Date
Published /
Revised
Version
No.
Author
Section / Description of Change
20 Aug 2020 1.0 Andy Mittura Initial Release
17 May 2021 1.1 Andy Mittura Updated per the EPR feedback
Refer questions concerning this Regional Unified Capabilities (UC) – VS Solution Architecture and CONOPS document to Andy Mittura, NCI Engineering Lead, 170.4 NCI, Marine Corps
System Command, 2200 Lester Street, Quantico, VA 22134-6050, commercial 703-784-4935, andrew.mittura@usmc.mil
Document Properties
Responsible Organization: Marine Corps Systems Command (MCSC) Solution Architect: Various (Site Contractors)
Cyber Lead: Jeffrey Miller, PEO-D, MCSES
Engineering Lead: Andy Mittura, PEO-D, MCSES
Operational Engineering Lead: Michael Caruso, MCCOG
Project Number: N/A (various site projects) mailto:andrew.mittura@usmc.mil
DRAFT: D400.12663.04.RUC_VS – May 2021 iii
Contents
1 Introduction
1.1 Purpose and Solution Overview
1.2 Background
1.3 Audience
1.4 Solution Goals and Objectives
1.5 Threats
1.5.1 Human Unintentional Threats
1.5.2 Human Intentional Threats
2 Capabilities and Requirements
2.1 Key Performance Parameters (KPP)
2.1.1 Regional Unified Capabilities
2.2 Key System Attributes
2.3 Major Functional Requirements
3 Architecture Context
3.1 Regional Construct
3.2 Relationship to Other Program Documentation
3.3 Operational Context
3.3.1 Business Voice
3.3.2 Voice Conferencing
3.3.3 Commercial Voice Access
3.3.4 Voice Mail
3.3.5 Unified Messaging
3.4 Exclusions
4 Solution Description
4.1 Solution Context
4.1.1 Tier A – Regional Hub Site
4.1.2 Tier B – Regional ISN Site
4.1.3 Tier C – Regional GSU Site
4.2 Voice Network
4.3 Components
4.4 Use Cases / Modes of Operation
4.4.1 Local On-Base Call
4.4.2 Base-to-Base Call
4.4.3 Commercial Call
4.4.4 E911 Calls
4.5 Adherence to Industry Standards and Best Practices
4.6 Architecture Implementation
4.7 Architecture Guidance
4.8 Continuing Governance
5 Solution Support
5.1 Roles and Responsibilities
DRAFT: D400.12663.04.RUC_VS – May 2021 iv
5.2 Training Requirements
5.3 Personnel Requirements
5.4 Non-Labor Resource Requirements
Appendix A: Acronyms and Abbreviations
Figures Figure 1. (FOUO) Site Capabilities
Figure 2. (FOUO) UC Regions and Associated Sites
Figure 3. (FOUO) Defined Regions and Installation Capabilities
Figure 4. (FOUO) Voice Data Flow
Figure 5. (FOUO) Reference Architecture – Tier A Site
Figure 6. (FOUO) Reference Architecture – Tier B Site
Figure 7. (FOUO) Reference Architecture – Tier C Site
Tables Table 1(FOUO) Traffic Conditioning Specification
Table 2 (FOUO) UC Architecture Components
Table 3 (FOUO) Roles and Responsibilities
Table 4 (FOUO) UC Architecture Training Requirements
Table 5 (FOUO) Appendix A: Acronyms and Abbreviations
DRAFT: D400.12663.04.RUC_VS – May 2021 1
1 Introduction
This document describes the architecture of the Regional Unified Capabilities (UC) of Voice
Services (VS) in the Marine Corps Network Communications Infrastructure (NCI) program.
1.1 Purpose and Solution Overview
(FOUO) The objective of this document is to define requirements and architecture for the provision of voice services at the regional enterprise. The Marine Corps NCI voice services are a regional design that aligns to the Wide Area Network (WAN) Transport Implementation Plan.
Voice Services include:
Business Voice
Voice Conferencing
Commercial Voice Access
Voicemail
Unified Messaging
Precedence-Based Voice.
The UC solution includes:
Session Border Controllers (SBCs)
Local Session Controllers (LSCs)
Media Gateways
Teleconferencing bridges
Voice mail
Telecommunications Management System (TMS).
1.2 Background
(FOUO) This architecture will replace existing non-Internet Protocol (IP) Private Branch
Exchanges (PBXs) used to provide telephone service at Base/Post/Camp/Stations (B/P/C/S).
Existing non-IP PBXs are beyond End-of-Life (EoL) and are nearing (or in some cases beyond)
End-of-Support (EoS). Additionally, it will replace/upgrade existing LSCs that have been installed in a stand-alone manner.
1.3 Audience
This document is intended as an architecture document for network architects and engineers.
It also has value for non-technical administrators and other senior staff.
DRAFT: D400.12663.04.RUC_VS – May 2021 2
1.4 Solution Goals and Objectives
(FOUO) This solution architecture is constructed to achieve the following goals with supporting objectives:
Enhance operational effectiveness
Enable continuity of operations, high availability and failover
Fully leverage enterprise services for telephony
Empower individual users to schedule and execute voice and video conferences directly, and give them the tools to effectively manage conferences in progress.
Reduce total cost of ownership of garrison communications systems
Consolidate disparate telephone, data, and video networks
Consolidate maintenance staffs and supply chains
Makes use of the voice Internet Services Provider (ISP) service provided by the
Defense Information Systems Agency (DISA)
Reduce work load on existing installations
Eliminates need for installation billing
Eliminates need for costly Integrated Services Digital Network (ISDN) circuits.
Remove EoS vulnerability of existing PBXs.
1.5 Threats
(FOUO) The solution is affected by threats in relation to its location on the network. These threats include denial of service both intentional and unintentional and unauthorized remote access attack.
1.5.1 Human Unintentional Threats
(FOUO) Human unintentional threats tend to be the result of accidents, lack of configuration management, failure to adhere to policy and/or procedural failures. Human unintentional threats for the UC segment include:
Misconfiguration: (FOUO) Improper configuration can cause systems to operate incorrectly or incompletely, or failure. This can in turn lead to communications failure, leading to mission / operations failure.
Lack of Configuration Management (CM): (FOUO) Lack of proper configuration management can lead to misconfiguration with the results described above. It can also lead to creating vulnerabilities that can be exploited by bad actors.
DRAFT: D400.12663.04.RUC_VS – May 2021 3
1.5.2 Human Intentional Threats
(FOUO) Specific human intentional threats for the UC architecture include:
Willful misconfiguration to create “taps” on data flows or to cause theft of services.
Willful extraction of configuration data and transmission to unauthorized users.
Malicious attacks to create Distributed Denial of Service (DDoS), data manipulation, data destruction and Malware.
DRAFT: D400.12663.04.RUC_VS – May 2021 4
2 Capabilities and Requirements
(FOUO) Increasingly, UC systems have evolved into powerful and comprehensive platforms to provide UC services for voice, video, instant messaging, collaboration, etc. They provide communications capabilities for enterprise users virtually anywhere, anytime, and on any platform.
(FOUO) At a high level, the United States Marine Corps (USMC) UC system must support robust UC capabilities and meet relevant requirements of the Department of Defense (DoD)
Unified Capabilities Requirements 2013 (UCR 2013, Change 2). The UCR specifies the functional requirements, performance objectives, and technical specifications for DoD networks that support UC, and shall be used to support test, certification, acquisition, connection, and operation of these devices.
2.1 Key Performance Parameters (KPP)
(FOUO) This section defines the Key Performance Parameters (KPPs) required to achieve the required UC capabilities delivered by the regional UC system. KPPs are the most essential benchmarks for the UC system to provide robust UC services within USMC installations, and reflect the USMC’s mission and operational requirements that must be met. All KPPs include
Threshold (T) and Objective (O) values that must be able to be validated through testing and/or analysis.
The regional UC system shall meet the following KPPs:
NGEN CPD (Version 1.5.7): Net-Ready KPP (Section 6.1.3)
DoD UCR-2013 (Change 2): Product Availability (Section 2.8.2.1)
2.1.1 Regional Unified Capabilities
(FOUO) A regional UC system shall consist of several installations connected in a cluster. One of the installations, normally the Component Enterprise Data Center (CEDC) or Tier A site, will serve as the main node and host the enterprise equipment. The regional UC system shall provide voice services to each user on each installation within the region. Each installation shall have a
SBC and a LSC to provide self-sustaining capabilities should it become separated from the region. The system shall have a TMS, along with a Voice Mail and Voice Conferencing system that supports the Region. The management, maintenance and operations of the UC system will be primarily performed from the regional site with each site responsible for Moves, Adds, Changes (MAC), and day-to-day operations.
DRAFT: D400.12663.04.RUC_VS – May 2021 5
Figure 1 depicts each Tier’s Site capabilities.
Figure 1. (FOUO) Site Capabilities
2.2 Key System Attributes
(FOUO) This section defines the Key System Attributes (KSAs) required to achieve the required
UC capabilities delivered by the UC system. They are considered essential to achieve a balanced solution/approach for the UC system, but not critical enough to be designated as KPPs.
All KSAs include Threshold and Objective values that must be able to be validated through testing and/or analysis. The regional UC system shall meet the following KSAs:
DoD UCR-2013 (Change 2): Service Class Performance Objective (Section 6.3.1)
The system shall be listed on the UC Approved Product List (APL.)
The system shall be capable of being installed in an incremental fashion one campus at a time.
The system shall provide Business voice, voice conferencing, commercial voice access, voice mail, and unified messaging as defined in the Functional Requirements
Document for Defense Enterprise Office Solutions.
Calls between Marine-to-Marine users shall be made without using the DISA soft switch backbone.
DISA Voice Internet Service Provider (VISP) shall be used as the primary interface for commercial voice access.
Transmitting and receiving (i.e., Direct Inward Dial) of point-to-point voice sessions from commercial voice networks via the VISP shall be provided to each installation.
DRAFT: D400.12663.04.RUC_VS – May 2021 6
Support the Differentiated Services Code Points (DSCP) markings to implement
Quality of Service (QoS)/ Class of Service (CoS).
Provide native audio Mean Opinion Score (MOS) of 3.8, at a minimum.
In accordance with (IAW) the Telecommunications Industry Association (TIA)
Telecommunications – IP Telephony Equipment – Voice Quality Recommendations for IP Telephony (TSB-116-A).
2.3 Major Functional Requirements
(FOUO) A regional UC system shall:
Consist of a LSC at each designated B/P/C/S.
Each LSC shall integrate with the other LSCs in its region in a coordinated cluster that provides full failover capability to other installations.
Each LSC shall provide a media gateway to accommodate the necessary analog services on the installation.
The regional UC shall provide the assignment of both a Defense Switched
Network (DSN) and commercial phone number to each end instrument.
Each LSC shall provide local survivability in the event it is severed from the Defense
Information Systems Network (DISN).
Support local session management when in a disconnected state.
Support local Enhanced 911 (E911) routing to the Public Safety Answering
Point (PSAP) or Emergency Response Center (ERC).
Remote users can utilize softphones through secure Virtual Private Networks (VPNs) from any location.
Automatic Call Distribution (ACD) shall be provided at the region.
Customer Service Support Applications (CSSAs) shall be provided at the region.
CSSAs shall provide call routing via Interactive Voice Recognition (IVR) for management, administration features.
CSSA shall support 400 agents.
CSSAs shall have a built in “heat map” to allow scheduling during peak usage vice time of day.
DRAFT: D400.12663.04.RUC_VS – May 2021 7
3 Architecture Context
(FOUO) The Marine Corps is implementing a network that has the ability to integrate voice, video, and data services delivered ubiquitously across an interoperable, secure, and highly available network infrastructure in accordance with the Joint Information Environment (JIE).
This environment calls for designated B/P/C/S to host core services in a regional construct and subordinate installations to reach into the designated sites for services.
The Unified Communications capabilities shall be designed as a regional enterprise solution.
There are six (6) regions: East, West, Pacific (PAC), Middle Pacific (MID PAC), National
Capital Region (NCR), and Enterprise. Figure 3 shows the sites in each region.
Figure 2. (FOUO) UC Regions and Associated Sites
DRAFT: D400.12663.04.RUC_VS – May 2021 8
Figure 3 displays the defined regions and installation capabilities.
Figure 3. (FOUO) Defined Regions and Installation Capabilities
3.1 Regional Construct
The regional construct applies a regional enterprise in order to minimize equipment and workload. It provides continuity of operations within the region by providing each Tier A and
Tier B installation with an SBC and a LSC to provide individual installations with dial tone and phone service. It consolidates at the Tier A location enterprise services including telecommunication management systems and voice mail.
Emergency call capability is maintained with PSAPs on designated installations and connection to Emergency services where applicable. Analog services are supported to support emergency phones, internal communications systems, alarms, monitoring stations and others.
Figure 4 shows the data flow for the different types of communications. Standard commercial communications and DSN communications utilize the SBC and DISA Voice over Internet
Protocol (VoIP) Virtual Routing and Forwarding (VRF). Additionally, the installation can have a second Local Exchange Carrier (LEC) ordered through Defense Information Technology
Contracting Organization (DITCO) and routed via the SBC. Marine-to-Marine calls between
DRAFT: D400.12663.04.RUC_VS – May 2021 9 installations are router without the SBC and over the closed Layer 3 Virtual Private
Network (L3VPN). Communications to and from a Geographically Separated Units (GSUs) are routed via a L3VPN to its host site.
ESINET
TMS
Server
Voicemail Server
Primary
LSC
Secondary
LSC
CEDC
ISN
GSU
DISA
SBC
DISA
SBC
Remote Survivable
LSC
Voice Conferencing Server
Voice Conferencing Server
Primary
LSC
Secondary
LSC
Marine
Marine to
NG 911
IPSEC
Tunnel
Closed USMC Transport
L3VPN
Closed USMC Traffic L3VPN
Commercial
Exchange
Carriers
VISP
SBC
LEC SIP Trunk
LEC SIP
Trunk
Voice Conferencing
Server
Voice Conferencing
Server
, DSN VISP
Commerical
DISA
USMC-VOIP-VRF
Figure 4. (FOUO) Voice Data Flow
3.2 Relationship to Other Program Documentation
(FOUO) This specification document is the first step in engineering level requirements and provides clarification and specificity to the requirements document. It provides the Concept of
Operations (CONOPS) for the system as it will be deployed or used in production. UC services ride on the transport system for the installations as defined in the Base Area Network (BAN)
DEV 400. The SBC architecture is further defined in the SBC DEV 400.
3.3 Operational Context
(FOUO) The UC solution will be used by installation users to obtain voice services, including voicemail and voice conferencing. Voice services include:
Business voice
Voice Conferencing
Commercial voice access
Voice mail
Unified messaging.
DRAFT: D400.12663.04.RUC_VS – May 2021 10
3.3.1 Business Voice
(FOUO) Non-Command and Control (C2) users who require voice (single-line and multi-line), access to E911, local, and long-distance dialing.
3.3.2 Voice Conferencing
(FOUO) The ability to link together multiple voice sessions in a multi-party conference, using a voice conference bridge or started from a telephony End Instrument (EI). Conferences can be ad hoc or pre-scheduled using persistent phone numbers and unique access codes. Individual point-to-point calls within a voice conference can have C2 features.
3.3.3 Commercial Voice Access
(FOUO) External voice connections for Sensitive but Unclassified (SBU) calls via a centralized, enterprise wide subscription based access point to the public telephone network.
Locally provided Internet Protocol (IP) circuits are by exception only and must comply with applicable DoD policies.
3.3.4 Voice Mail
(FOUO) An electronic communication system in which spoken messages are recorded or digitized and stored for later playback to the intended recipient.
3.3.5 Unified Messaging
(FOUO) The ability to retrieve voice, fax, and email messages that a user can access either with an email client or by telephone. Voice messages can be transcribed into email, and emails can be digitized into voicemail.
3.4 Exclusions
Not applicable.
DRAFT: D400.12663.04.RUC_VS – May 2021 11
4 Solution Description
(FOUO) The UC architecture provides session management for session-based information exchanges. It also provides firewall protection for voice traffic, and interfaces to non-IP transmission systems as required for voice traffic.
4.1 Solution Context
(FOUO) Not every B/P/C/S receives a full suite of hardware. Tier A sites host voicemail, voice conferencing, and a centralized TMS. Tier A and Tier B sites receive SBCs and LSCs.
Since they have direct access to the Joint Base Provider Edge (JB-PE) device, they will have direct DSN access. Tier C sites or GSUs will have a remote survivable unit, which will only provide local communications in the event of a loss of connection to the host installation.
Figures 5, 6, and 7 provide the individual capabilities at each B/P/C/S depending on the designated tier level.
4.1.1 Tier A – Regional Hub Site
(FOUO) UC Regional Hubs (Tier A sites) shall contain the basic system capabilities including but not limited to SBCs, a Session Manager, and Voice Conferencing. This type of site shall host consolidated equipment to support the region by providing a Telecommunications
Management System, Voice Mail, license management, and a subscriber database. Tier A Sites shall provide patch management for region as well as provide regional operations support to
Tier B and C sites. Dual Points of Presence (PoPs) shall provide high availability for all external communications. DSN and Commercial carriers shall be accessible via DISA. There shall be a separate LEC interface for local commercial connections. Emergency Services IP
Network (ESInet) shall interface to support local PSAP for Next Generation 911 (NG911).
Marine-to-Marine communications shall traverse over the L3VPN, which saves on Session
Initiation Protocol (SIP) trunking.
DRAFT: D400.12663.04.RUC_VS – May 2021 12
Figure 5 depicts a UC Architecture for a Regional Hub Site.
MCEN-N
Core
Router
(B)
QFP
DISA
SBC
VoIP
EUDs
MCEN-N
Core
Router
(A)
QFP
MCEN
CORE
SWITCH
(A)
UC Architecture Tier A Site
BAN Core
Router (B)BAN Core
Router (A)
MCEN
CORE
SWITCH
(B)AS-LAN
Primary
SBC
V
TMS
Server
Voicemail Server
Primary
LSC
Secondary
LSC
Voice Conferencing
Server
Voice
Switches
Voice Conferencing
Server
DISA
SBC
ESINET
DISA
JB PE
QFP QFP
DISA
JB PE
BCF
V
Closed USMC Transport
L3VPN
LEC SIP Trunk
SIP
SIP
Commercial
Exchange
Carriers
VISP
SBC DISA
USMC-VoIP-VRF
Figure 5. (FOUO) Reference Architecture – Tier A Site
4.1.2 Tier B – Regional ISN Site
(FOUO) UC Regional ISN (Tier B sites) shall contain the basic system capabilities, including, but not limited to, SBCs, a Session Manager, and Voice Conferencing. This type of site shall maintain access to consolidated equipment to provide the installation support (Moves, Adds, Changes). In addition, Tier B sites shall provide failover capability to Tier A sites. Dual PoPs shall provide high availability for all external communications. DSN and Commercial carriers shall be accessible via DISA. There shall be a separate LEC interface for local commercial connections. ESInet shall interface to support local PSAP for NG911. Marine-to-Marine communications shall traverse over the L3VPN, which saves on SIP trunking. The Tier B sites
DRAFT: D400.12663.04.RUC_VS – May 2021 13 shall leverage enterprise services, including, but not limited to, TMSs and Voice Mail from a regional hub.
Figure 6 depicts a UC Architecture for a Regional ISN Site.
MCEN-N
Core
Router
(B)
QFP
DISA
SBC
VoIP
EUDs
Commercial
Exchange
Carriers
MCEN-N
Core
Router
(A)
QFP
MCEN
CORE
SWITCH
(A)
UC Architecture Tier B Site
BAN Core
Router (B)BAN Core
Router (A)
MCEN
CORE
SWITCH
(B)AS-LAN
Primary
SBC
V
Primary
LSC
Secondary
LSC
Voice Conferencing
Server
Voice
Switches
Centralized Telecom Mgmt
System
DISA
SBC
ESINET
LEC SIP Trunk
SBC
BCF
V
SIP
Commercial
Exchange
Carriers
VISP
SBC
DISA
Figure 6. (FOUO) Reference Architecture – Tier B Site
DRAFT: D400.12663.04.RUC_VS – May 2021 14
4.1.3 Tier C – Regional GSU Site
(FOUO) UC Regional GSUs (Tier C sites) contain local survivable capability to support the enclave in the event it is severed from its host. A Tier 3 site shall have a survivable session controller to provide enclave communications in the event it becomes disconnected. This site shall utilize a L3VPN connection to a Tier A or B site for voice service.
Figure 7. (FOUO) Reference Architecture – Tier C Site
TIER A
Core
Router
QFP
VOIP
EUDs
Commercial
Exchange
Carriers
MCEN-N
Core
Router QFP
MCEN CORE
SWITCH
UC Architecture Tier C Site
Boundary
Router
AS-LAN
V
Remote Survivable
LSC
Voice
Switches
DISA
JB-PE
DISA
JB-PE
V
QFP
QFP QFP
Commercial
DITCO
Lease
IPSEC Tunnel
JIE
JB-CE
Tier A Site
Closed USMC Transport
L3VPN
DRAFT: D400.12663.04.RUC_VS – May 2021 15
4.2 Voice Network
(FOUO) The voice network consists of an Assured Services-Local Area Network (AS-LAN) and the user distribution. The AS-LAN consists of the Local Session Controller, Telecommunications Management System (TMS). The AS-LAN is protected and interfaced to the BAN via a pair of Layer 3 switches executing ACLs. These ACLs allow the LSC and TMS to take advantage of enterprise services to include PKI, AAA, DNS, DHCP, HBSS, NTP and syslog.
(FOUO) The Marine Corps has implemented a private IP scheme for the voice traffic. An allocation of the 10.X.X.X network has been defined for each B/P/C/S. Each region and each installation in that region has been allocated a block of private IPs.
(FOUO) Separate Virtual Local Area Networks (VLANs) are used to segregate voice traffic. In conjunction with the BAN architecture scheme, voice will utilize extended VLANS and indicate zones on each installation associated with the distribution nodes. The tens digit in the extended
VLAN Identification (ID) will indicate the zone.
(FOUO) Extended VLANs in the range of 1200-1399 are reserved for IP Phones.
Voice VLANs 1210-1219 are in Zone 1.
Voice VLANs 1220-1229 are in Zone 2.
Voice VLANs 1370-1379 are in zone 17.
VLANs 1380 – 1397 are reserved for voice servers.
VLANs 1398 and 1399 are reserved for maintenance.
DRAFT: D400.12663.04.RUC_VS – May 2021 16
The USMC VoIP VPN shall implement QoS. The DSCP plan to be used is described in Table 1.
Table 1(FOUO) Traffic Conditioning Specification
AGGREGATED
SERVICE CLASS
GRANULAR SERVICE CLASS
PRIORITY/
PRECEDENCE
DSCP
BASE10
DSCP
BINARY
DSCP
BASE8
Network Control Network Signaling (OSPF, BGP, etc.) N/A 48 110 000 60
User Signaling (AS-SIP or SIP) N/A 40 101 000 50
Short Message FO 32 100 000 40
FO 41 101 001 51
F 43 101 011 53
I 45 101 101 55
P 47 101 111 57
R 49 110 001 61
SIP Voice ** N/A 46 101 110 56
Assured Multimedia FO 33 100 001 41
F 35 100 011 43
I 37 100 101 45
P 39 100 111 47
Broadcast Video N/A 24 011 000 30
FO 25 011 001 31
F 27 011 011 33
I 29 011 101 35
P 31 011 111 37
R 26 011 010 32
FO 17 010 001 21
F 19 010 011 23
I 21 010 101 25
P 23 010 111 27
R 18 [20,22]*** 010 010 22
FO 9 001 001 11
F 11 001 011 13
I 13 001 101 15
P 15 001 111 17
R 10 [12,14]*** 001 010 12
OA&M N/A 16 010 000 20
Best Effort N/A 0 000 000 0
Elastic Low Priority Data N/A 8 001 000 10
** For a definition, see UC Framework 2013, Appendix C, Definitions, Abbreviations and Acronyms, and References.
*** Code points in brackets are reserved for nonconformance marking.
AS-SIP Voice * (Includes SRTCP)Inelastic Real-Time
Conferencing (voice, video, and data)
(code points 28, 30, 34, 36, and 38 are for Non-Assured Multimedia
Conferencing) R 51 [28, 30, 34,36,38]*** 110 011 63
AS-SIP: Assured Services Session Initiation Protocol N/A: Not Applicable
BGP: Border Gateway Protocol OA&M: Operations, Administration, and Maintenance DSCP: Differentiated Services Code
Point OSPF: Open Shortest Path First
F: FLASH P: PRIORITY
FO: FLASH OVERRIDE R: ROUTINE
IM: Instant Messaging SRTCP: Secure Real-Time Transport Control Protocol I: INTERMEDIATE
* Priority precedence applies to AS-SIP only.
LEGEND:
Multimedia Streaming
Preferred Elastic Low-Latency Data: (IM, Chat, Presence)
High Throughput Data (Real-Time Data
Backup, Web Hosting)
DRAFT: D400.12663.04.RUC_VS – May 2021 17
4.3 Components
Error! Reference source not found. lists the components of the UC architecture, describes their function, and indicates where they are used.
Table 2 (FOUO) UC Architecture Components
Item Description Where Used
Local Session
Controller
Hardware and software to set up, tear down, and manage session-based information exchanges, including all switched voice and video calls.
Also addresses data sharing and collaboration activities if they are session-based.
All installations
Session Border
Controller
A network element that exerts control over the signaling and the media streams involved in setting up, conducting, and tearing down calls. The SBC enforces security, quality of service and admission control mechanism over the VoIP sessions.
All Installations
TMS Application
Server that enables Marine Corps telecom maintenance
/ administration personnel to access the TMS databases to update configuration records and create work tickets for moves, adds, changes, and repairs.
CEDC only
TMS Database Server that houses master configuration databases for all telecom assets CEDC only
TMS Management
Server that houses user accounts, permissions, and other information required to operate the TMS as a single entity for all B/P/C/S served by the region in question
CEDC only
Conference Bridge
Hardware and software that manages and provides voice conferences for all B/P/C/S served by the region in question
CEDC only
Voicemail Server that provides voicemail services for all
B/P/C/S served by the region in question CEDC only
Telephony gateways
Media gateways that translate IP-based telephony capabilities into non-IP (e.g., TDM, analog) telephony services. Gateways are used both to connect to analog telephone sets and to non-IP trunk circuits to access
DSN and the PSTN.
All installations
L3 switch
A physical or virtual Layer 3 switching device that connects all UC Architecture components to the
BAN Distribution Routers.
All installations
Administrative workstation
Workstation (e.g., PC) that is used to access the
UC Architecture components for local configuration.
DRAFT: D400.12663.04.RUC_VS – May 2021 18
4.4 Use Cases / Modes of Operation
Error! Reference source not found. lists some significant use cases for the UC Architecture.
This list is by no means exhaustive.
4.4.1 Local On-Base Call
All 7- or 10-digit dialing, call is routed on base.
4.4.2 Base-to-Base Call
(FOUO) All 10-digit dialing, call is routed to destination base without SBC involvement.
If 99 or 991 is dialed, call is routed as shown in Section 4.4.1.
4.4.3 Commercial Call
(FOUO) Calls originating on base shall be 10-digit dialing and be routed to the SBC for transmission to VISP SBC
Calls originating off base shall be routed to the SBC for transmission to the LSC.
4.4.4 E911 Calls
4.4.4.1 Installations with a PSAP
(FOUO) E911 calls originating from an on-base phone shall be routed directly to the PSAP.
Commercial calls shall route to the PSAP via ESInet from the commercial carrier.
4.4.4.2 Installations without a PSAP
(FOUO) E911 calls originating from an on-base phone shall be routed to ESInet via the DSN interface.
4.5 Adherence to Industry Standards and Best Practices
The UC Architecture uses open-standard protocols and Commercial Off-the-Shelf (COTS) products.
4.6 Architecture Implementation
(FOUO) The UC Architecture will be implemented in a phased manner. To the extent possible, Installation Processing Node (IPN) capabilities will be deployed prior to deployment of ISN capabilities. Because the phasing will extend across several years, continued interoperability of
IP and non-IP voice systems must be planned for and designed into the architecture from the beginning. This may, in some cases, result in a greater amount of hardware (e.g., telephony gateways) being deployed than would be required in a greenfield deployment.
4.7 Architecture Guidance
(FOUO) The UC Architecture will be managed by the NCI Program Office.
4.8 Continuing Governance
TBD
DRAFT: D400.12663.04.RUC_VS – May 2021 19
5 Solution Support
5.1 Roles and Responsibilities
Error! Reference source not found. lists the Roles and the Responsibilities for UC
Architecture.
Table 3 (FOUO) Roles and Responsibilities
Legend:
Responsible (R)
Accountable (A)
Support (S)
Consulted (C)
Informed (I)
M C
S C
H Q
M C
C
M F
C C
/M C
C O
G
M
IC
O
D
I
R eg io n al G
F A
Define Technical Requirements AR SC C R C C C
Conduct In-Service Engineering and Update
Solution Design Documentation
AR I S C C
Conduct FCA AR C S S
Conduct Applied Engineering and Create
Site Configuration Design Documentation –
Initial Solution Deployment
AR I S I S C
Conduct Applied Engineering and Update
Site Configuration Design Documentation –
Post Initial Solution Deployment
AR I C C C C
Conduct PCA AR C
Establish and Sustain Development Lab
Equipment (Includes Facility Dependencies)
AR S
Operate (Manage and Administer)
Development Lab
AR S
Establish and Sustain Production Equipment
(Includes Facility Dependencies)
AR C S S
Operate (Manage and Administer)
Production
C C AR
Maintain Type Accreditation R A S
Maintain Site Accreditations S A S R
R = Responsible - Those responsible for the task, who ensure that it is done as per the approver. There is at least one role with a participation type of responsible, although others can be delegated to assist in the work required
(see Support role).
A = Accountable - The one ultimately answerable for the correct and thorough completion of the deliverable or task, and the one who delegates the work to those responsible. In other words, an accountable must sign off (approve) work that responsible provides. There must be only one accountable specified for each task or deliverable.
S = Support - Resources allocated to Responsible. Unlike consulted, who may provide input to the task, support help complete the task.
C = Consulted - Those whose opinions are sought, typically subject matter experts; and with whom there is two-way communication. (Implies I-Informed)
I = Informed - Those who are kept up-to-date on progress, often only on completion of the task or deliverable; and with whom there is just one-way communication. Those who are assigned the “Informed” level of responsibility have no required work to support a task or deliverable, but are kept up-to-date on work progress or notified once the work or deliverable is completed. Typically, communications with those in an “Informed” role are purely one-way from those who are Accountable or Responsible.
DRAFT: D400.12663.04.RUC_VS – May 2021 20
5.2 Training Requirements
Error! Reference source not found. describes the training requirements for the UC
Architecture.
Table 4 (FOUO) UC Architecture Training Requirements
Area Item Users Maint
Personnel
Local
Admin
Enterprise
Admin
Local Session
Controller (LSC) End-user operations X X X X
Local Session
Controller (LSC)
Hardware / software maintenance X
Local Session
Controller (LSC) Administration X X X
Voice Firewalls Configuration X X
Voice Firewalls Maintenance X
ETM Database /
ETM Management Configuration X X X
ETM Database /
ETM Management Maintenance X
TMS Application Local administration X X X
TMS Application Ticket creation / annotation / resolution X X
TMS Application Report generation X X
TMS Application Configuration records X X
TMS Database Database administration X
TMS Database Hardware / software maintenance X
TMS Management Enterprise management X X
TMS Management Hardware / software maintenance X
Conference Bridge End-user operations X X X X
Conference Bridge Account management X X
Conference Bridge Hardware / software maintenance X
Voicemail End-user operations X X X X
Voicemail Account management X X
Voicemail Hardware / software maintenance X
Telephony gateways Configuration X X
DRAFT: D400.12663.04.RUC_VS – May 2021 21
Area Item Users Maint
Personnel
Local
Admin
Enterprise
Admin
Telephony gateways
Hardware / software maintenance X
L3 switch Configuration X X
L3 switch Hardware / software maintenance X
Administrative workstation Configuration X X
Administrative workstation
Hardware / software maintenance X
5.3 Personnel Requirements
(FOUO) The total number of personnel and their types required to maintain the UC Architecture, as well as their job classifications, are to be determined.
5.4 Non-Labor Resource Requirements
(FOUO) The UC Architecture will require at least the following non-labor resources. This is not a complete list:
A complete set of on-site spares at each B/C/P/S, or a regional depot of spares and a way to move them quickly (i.e., within 1 day) from the regional depot to any installation.
Test equipment for analyzing network performance.
Manufacturer’s recommended test assets (to be determined).
Electricity.
Heating, Ventilation, and Air Conditioning (HVAC) that operates independently of building HVAC, or which is otherwise configured to be continuously available.
Suitable space for installation.
Systems Integration Laboratory (SIL) support.
DRAFT: D400.12663.04.RUC_VS – Aug 2020 A-1
Appendix A: Acronyms and Abbreviations
Table 5 (FOUO) Appendix A: Acronyms and Abbreviations
Acronym or
Abbreviation
Definition
ACD Automatic Call Distribution
APL Approved Product List
AS-SIP Assured Services Session Initiation Protocol
B/P/C/S Base/Post/Camp/Station
BAN Base Area Network
BGP Border Gateway Protocol
C2 Command and Control
CEDC Component Enterprise Data Center
CM Configuration Management
CMP Configuration Management Plan
CONOPS Concept of Operations
CoS Class of Service
COTS Commercial Off-the-Shelf
CSSA Customer Service Support Application
DEVDOC Development Documentation
DISA Defense Information Systems Agency
DISN Defense Information Systems Network
DITCO Defense Information Technology Contracting Organization
DoD Department of Defense
DoDD Department of Defense Directive
DDoS Distributed Denial of Service
DSCP Differentiated Services Code Point
DSN Defense Switched Network
E911 Enhanced 911
EI End Instrument
EoL End-of-Life
EoS End-of-Support
ERC Emergency Response Center
ESInet Emergency Services IP Network
F Flash
FO Flash Override
FOUO For Official Use Only
DRAFT: D400.12663.04.RUC_VS – Aug 2020 A-2
Acronym or
Abbreviation
Definition
GSU Geographically Separated Unit
HQMC Headquarters Marine Corps
HVAC Heating, Ventilation, and Air Conditioning
I Intermediate
IAW In Accordance With
ID Identification
IM Instant Messaging
IP Internet Protocol
IPN Installation Processing Node
ISDN Integrated Services Digital Network
ISN Installation Services Node
ISP Internet Service Provider
IT Information Technology
IVR Interactive Voice Recognition
JB-PE Joint Base Provider Edge
JIE Joint Information Environment
KPP Key Performance Parameter
KSA Key System Attribute
L3VPN Layer 3 Virtual Private Network
LAN Local Area Network
LEC Local Exchange Carrier
LSC Local Session Controller
LSE Lead Systems Engineer
MAC Moves, Adds, Changes
MAGTF Marine Air-Ground Task Force
MARFORCOM U.S. Marine Corps Forces Command
MARFOREUR-AF U.S. Marine Corps Forces Europe – Africa
MARFORK U.S. Marine Corps Forces Korea
MARFORRES Marine Forces Reserve
MCAGCC Marine Corps Air Ground Combat Center
MCAS Marine Corps Air Station
MCB Marine Corps Base
MCBH Marine Corps Base Hawaii
MCEN Marine Corps Enterprise Network
MCEN-N Marine Corps Enterprise Network – Non-Classified Internet
Protocol Router Network
DRAFT: D400.12663.04.RUC_VS – Aug 2020 A-3
Acronym or
Abbreviation
Definition
MCICOM Marine Corps Installations Command
MCITC Marine Corps Information Technology Center
MCLB Marine Corps Logistics Base
MCMWTC Marine Corps Mountain Warfare Training Center
MCNOSC Marine Corps Network Operations and Security Command
MCRD Marine Corps Recruit Depot
MCSC Marine Corps Systems Command
MID PAC Middle Pacific
MITSC MAGTF Information Technology Support Center
MOS Mean Opinion Score
N&I Network and Infrastructure
N/A Not Applicable
NAS Naval Air Station
NCI Network Communications Infrastructure
NCR National Capital Region
NG911 Next Generation 911
NIPRNet Non-Classified Internet Protocol Router Network
NIWC Naval Information Warfare Center
NOLA New Orleans, Louisiana
O Objective
OA&M Operations, Administration, and Maintenance
OPNAVINST Office of the Chief of Naval Operations
OSP Outside Plant
OSPF Open Shortest Path First
P Priority
PAC Pacific
PC Personal Computer
PCA Physical Configuration Audit
PBX Private Branch Exchange
PC Personal Computer
PoP Point of Presence
PSAP Public Safety Answering Point
PSTN Public Switched Telephone Network
QoS Quality of Service
R Routine
RTM Requirements Traceability Matrix
DRAFT: D400.12663.04.RUC_VS – Aug 2020 A-4
Acronym or
Abbreviation
Definition
RUC Regional Unified Capabilities
SBC Session Border Controller
SBU Sensitive but Unclassified
SC Session Controller
SE Systems Engineering
SI System Integrator
SIL Systems Integration Laboratory
SIP Session Initiation Protocol
SME Subject Matter Expert
SRTCP Secure Real-Time Transport Control Protocol
T Threshold
TDM Time Division Multiplexing
TIA Telecommunications Industry Association
TCP Transmission Control Protocol
TMS Telecommunications Management System
TSB Technical Service Bulletins
UC Unified Capabilities
UCR Unified Capabilities Requirements
USMC United States Marine Corps
VDI Video Device Interface
VISP Voice Internet Service Provider
VLAN Virtual Local Area Network
VoIP Voice over Internet Protocol
VPN Virtual Private Network
VRF Virtual Routing and Forwarding
VS Voice Services
WAN Wide Area Network
WLAN Wireless Local Area Network