This is an Asbestos Survey Report prepared by Terracon Consultants, Inc. for the Kent Intermediate School District regarding the former Dutton Elementary School located at 3820 68th Street, Caledonia, Michigan. The survey was conducted on April 1, 2, 3, and 8, 2026, by two Board for Global EHS Credentialing Certified Industrial Hygienists in accordance with USEPA 40 CFR Part 763, Subpart E (AHERA) protocols. The survey was performed in anticipation of future demolition of the approximately 60,000 square-foot building, which consists of a gymnasium, cafeteria, kitchen, library, restrooms, offices, and classrooms. Terracon collected a total of 339 bulk samples from 112 homogeneous areas of suspect asbestos-containing materials (ACMs) and submitted them to Scientific Analytical Institute for analysis by polarized light microscopy (PLM) using EPA Method 600/R-93/116.
The survey identified six homogeneous areas containing asbestos-containing materials: gray mortar associated with ceramic floor tiles in restrooms (0.25% chrysotile, Category II non-friable); gray mortar associated with red ceramic tile in Room 4109 (0.75% chrysotile, Category II non-friable); white interior wall expansion joint caulk in multiple rooms (2% chrysotile, Category II non-friable); gray exterior window frame caulk (2% chrysotile, Category II non-friable); and dark gray exterior wall expansion joint caulk at EIFS (2% chrysotile, Category II non-friable). Additionally, a tan and brown vinyl tile with yellow mastic in the corridor tested positive for asbestos (6% chrysotile tile, 2% chrysotile mastic). Estimated quantities of identified materials range from 2 square feet for caulk to 600 square feet for mortar. The report notes that contractor estimates regarding actual quantities present may vary significantly, particularly if ACMs exist in hidden or inaccessible areas not evaluated during the survey. Per Michigan regulations, notification to the Michigan Department of Licensing and Regulatory Affairs (LARA) must be provided at least 10 days prior to any abatement project exceeding 10 linear feet or 10 square feet.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey Report Former Dutton Elementary School
3820 68th Street | Caledonia, Michigan 49316
May 11, 2026 | Terracon Project Number: LD267060
Prepared for:
Kent Intermediate School District Grand Rapids, Michigan
Prepared by:
Terracon Consultants, Inc.
Grand Rapids, Michigan
400 Ann Street NW Suite 204
Grand Rapids, Michigan 49504 P (616) 226-8180
Terracon.com
Facilities | Environmental | Geotechnical | Materials
May 11, 2026
Kent Intermediate School District 2930 Knapp Street NE Grand Rapids, Michigan 49525
Attn: Mr. Russell Bray P: (616) 447-2444 E: russellbray@kentisd.org
Re: Asbestos Survey Report Former Dutton Elementary School 3820 68th Street Caledonia, Michigan 49316 Terracon Proposal No. LD267060
Dear Mr. Bray:
Terracon Consultants, Inc. (Terracon) is pleased to submit the attached asbestos survey report to Kent Intermediate School District (Client) regarding the former Dutton Elementary School at the above-referenced address. The purpose of this report is to present the results of an asbestos survey, which was performed on April 1, 2, 3, and 8, 2026. The asbestos survey was conducted in general accordance with our proposal number PLD267060, dated March 18, 2026. We understand that this survey was requested for the purpose of future demolition of the former elementary school located at 3820 68th Street, Caledonia, Michigan.
Asbestos-containing materials (ACMs) were identified as a result of this survey. Please refer to the attached report for details. Terracon appreciates the opportunity to provide this service to the Kent Intermediate School District. If you have any questions regarding this report or require additional services, please give us a call.
Sincerely, Terracon Consultants, Inc.
Jeff Fusee, CIH, CSP Joseph A. Tussey, CHMM Project Industrial Hygienist Principal
Former Dutton Elementary School | 3820 68th St., Caledonia, MI May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
1.2 Reliance
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 REGULATORY OVERVIEW
5.0 FINDINGS AND RECOMMENDATIONS
6.0 LIMITATIONS/GENERAL COMMENTS
APPENDIX A IDENTIFIED AND ASSUMED ASBESTOS-CONTAINING MATERIALS BY
HOMOGENEOUS AREA (HA)
APPENDIX B ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA
APPENDIX D FLOOR PLAN
APPENDIX E PHOTOGRAPHS
APPENDIX F CIH CREDENTIALS
Facilities | Environmental | Geotechnical | Materials 1
ASBESTOS SURVEY REPORT
Former Dutton Elementary School
3820 68th Street Caledonia, Michigan 49316
Terracon Project No. LD267060 May 11, 2026
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey of the former Dutton Elementary School located at 3820 68th Street in Caledonia, Michigan. The asbestos survey was conducted on April 1, 2, 3, and 8, 2026, by two (2) Board for Global EHS Credentialing Certified Industrial Hygienists (CIH) in general accordance with Terracon’s proposal number PLD267060, dated March 18, 2026. Safely accessible building components were surveyed, and homogeneous areas of suspect accessible asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to inspect accessible suspect materials, additional suspect but un-sampled materials could be located in walls, in voids, or in other concealed areas. Bulk samples from suspect ACM were collected in general accordance with the sampling protocols outlined in United States Environmental Protection Agency (USEPA) 40 Code of Federal Regulations (CFR) Part 763, Subpart E, known as the Asbestos Hazard Emergency Response Act (AHERA). Collected bulk samples were delivered to an accredited laboratory for analysis of asbestos content by polarized light microscopy (PLM).
1.1 Project Objective
We understand that this survey was requested for planned demolition of the former Dutton Elementary School building. Asbestos inspections/surveys are required prior to renovation and demolition activities to satisfy requirements of the USEPA 40 CFR Part 61, Subpart M, the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation and Michigan asbestos regulations.
1.2 Reliance
This report is for the exclusive use of Kent Intermediate School District (Client) for the project being discussed. Reliance by any other party on this report is prohibited without written authorization of Terracon and the Client. Reliance on this report by the Client and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal, this report, and the agreement between Terracon and the Client. The limitations of liability defined in the agreement is the aggregate limit of Terracon’s liability to the Client.
Former Dutton Elementary School | | 3820 68th St., Caledonia, MI May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials 2
2.0 BUILDING DESCRIPTION
The abandoned, former Dutton Elementary School is approximately 60,000 square feet consisting of a gymnasium, cafeteria, kitchen, library, restrooms, offices, and classrooms.
The original date of construction was unknown to Terracon. The building was reported to have a library/office addition and a gym addition added later after the original construction (construction dates of the additions were also unknown to Terracon). As reference, Appendix D includes a general floor plan diagram (not to scale) of the building.
3.0 FIELD ACTIVITIES
The asbestos survey was conducted by Mr. Jeff Fusee, CIH, CSP (CIH Credential No. 10961 CP) and Mr. Joshua Schroedter, CIH (CIH Credential No. 12641 CP). A copy of their CIH credential is included in Appendix F.
The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763, Subpart E, Section 763.86 - AHERA. A summary of survey activities is provided below.
3.1 Visual Assessment
Survey activities were initiated with visual observation of the safely accessible interior and exterior areas of the building to identify homogeneous areas of accessible suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.
3.2 Physical Assessment
A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observation, bulk samples from suspect ACM were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release.
Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials 3
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.
Terracon collected a total of 339 bulk samples from 112 homogeneous areas of suspect ACM. A summary table of samples collected from homogenous areas of suspect ACM is included in Appendix B.
3.4 Sample Analysis
Bulk samples were submitted under chain of custody to Scientific Analytical Institute (SAI) of Greensboro, North Carolina for analysis by PLM via the USEPA Methods 600/R-93/116.
The percentage of asbestos, where applicable, was determined by microscopic visual estimation using PLM. When applicable, the additional point count method (400 points) was utilized for samples identified to contain asbestos by PLM at low concentrations. SAI is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), accreditation number 200664-0.
A summary of results is included with the summary of collected samples in Appendix B.
The laboratory analytical reports are included in Appendix C.
4.0 REGULATORY OVERVIEW
The asbestos National Emission Standards for Hazardous Air Pollutants (NESHAP) regulation (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. All friable ACM is considered regulated asbestos-containing material (RACM).
The asbestos NESHAP regulation classifies ACM as either RACM, Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable ACM; Category I non-friable ACM that has become friable or will be or has been subjected to sanding, grinding, cutting, or abrading; and Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar, and grouts.
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials 4
The Michigan Department of Environment, Great Lakes, and Energy (EGLE), Air Quality Division (AQD), enforces the asbestos NESHAP as adopted by 10 CSR 10-6.080. The owner or operator must provide EGLE with written notification at least ten working days prior to the commencement of asbestos abatement activities that will disturb RACM in amounts greater than or equal to 160 square feet, 250 linear feet, or 35 cubic feet.
In Michigan, asbestos regulations are also enforced by the Michigan Department of Licensing and Regulatory Affairs (LARA), Michigan Occupational Safety and Health Administration (MIOSHA). The LARA/MIOSHA Asbestos Program is responsible for the enforcement of most Michigan asbestos regulations. This program has the following six major areas of responsibility: 1) approval of asbestos training courses, 2) accreditation of workers, 3) licensing of asbestos abatement contractors, 4) processing of asbestos abatement project notifications (requires project notification at least 10 days prior to any non-emergency abatement project exceeding 10 linear feet or 10 square feet or both), 5) compliance investigations, and 6) EPA AHERA management plan review.
The U.S. Occupational Safety and Health Administration (OSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard classifies construction and maintenance activities that could disturb ACM and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for handling materials containing asbestos in concentrations less than or equal to one percent.
5.0 FINDINGS AND RECOMMENDATIONS
Based on the laboratory analytical report, the presence of asbestos was identified in samples collected from the former Dutton Elementary. A summary of identified asbestos-containing materials is included in Appendix A.
An asbestos survey sample summary is included in Appendix B. The laboratory analytical report are included in Appendix C. Photos of identified ACMs are included in Appendix E.
Please note that suspect materials other than those identified during the survey (e.g., materials concealed/hidden in walls; materials not listed in Appendix A and Appendix B) may exist. Should suspect materials other than those which were identified during this survey be uncovered prior to or during demolition activities, those materials should be assumed asbestos-containing until sampling and analysis can confirm or refute their asbestos content.
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials 5
6.0 LIMITATIONS/GENERAL COMMENTS
The asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the subject building. The information contained in this report is relevant to the dates on which this survey was performed and may not be representative of conditions at a later date. This report has been prepared on behalf of and exclusively for use by Kent Intermediate School District. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding quantities of ACM and any further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
Facilities | Environmental | Geotechnical | Materials
APPENDIX A
Former Dutton Elementary School
3820 68th Street Caledonia, Michigan 49316
Terracon Project No. LD267060
IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)
HA No. ACM Description Material Location
Percent and Type Asbestos
EPA NESHAP
Classification
Condition Estimated Quantity*
260401-22 Gray Mortar Associated with Blue and White 1”x1” Ceramic Floor Tile
Restroom 3 0.25% Chrysotile by Point
Count
Not Regulated by
EPA NESHAP (<1%
Asbestos by Point Count); However, Regulated by MIOSHA and Federal
OSHA
Good 180 square feet (sf)
260401-24 Gray Mortar Associated with Tan and Yellow 1”x1” Ceramic Floor Tile
Restroom 4 0.50% Chrysotile by Point
Count Good 100 sf
260401-41
Tan with Brown Streaks 9”x9” Vinyl Floor Tile and
Black Mastic (Under Carpet)
Room 4101 Room 4102 Room 4103 Room 4104
6% Chrysotile (Tile) 2% Chrysotile (Mastic)
Category I Non-Friable ACM
Good 4,000 total sf
260401-46 Joint Compound within the Drywall System – Ceiling
Restroom 7 Restroom 8
Mechanical Room (Concealed Above
Non-ACM Acoustical Drop Ceiling Tile in Restrooms)_
0.75% Chrysotile by Point Count (1 Sample Result);
However, Only 1 Sample was Identified with a Joint
Compound Layer;
Therefore, Assumed >1% in the Absence of a 2nd
Joint Compound Layer Sample Result Reported)
RACM Good 600 total sf
260401-53 Gray Mortar Associated with Red 6”x6” Ceramic Tile Floor Tile
Room 4109 0.75% Chrysotile by Point
Count Category II
Non-Friable ACM Good 425 sf
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials 7
*Estimated quantities listed above are based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACMs are present in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document; contractors would be responsible for drawing their own conclusions regarding quantities present. See the appendix documents for a summary of samples collected, laboratory analytical reports and photo examples of the above identified materials.
HA No. ACM Description Material Location
Percent and Type Asbestos
EPA NESHAP
Classification
Condition Estimated Quantity*
260401-55 White Interior Wall
Expansion Joint Caulk
Room 4108 Room 4110A Room 4106
2% Chrysotile Category II
Non-Friable ACM Good 2 sf
260401-61 Gray Exterior Window
Frame Caulk Exterior (At Windows)
2% Chrysotile Category II
Non-Friable ACM Good 25 sf
260401-67 Dark Gray Exterior Wall Expansion Joint Caulk at
EIFS
Exterior (At EFIS) 2% Chrysotile
Category II Non-Friable ACM
Good 50 sf
Facilities | Environmental | Geotechnical | Materials
APPENDIX B
Former Dutton Elementary School
3820 68th Street, Caledonia, Michigan 49316 Terracon Project No. LD267060
ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
Original Building (260401)
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
2’x4” Ceiling Tile
Room 4121
Room 4121
Restroom 1 Restroom 2
4117A 4123B Office 1
Corridor
Ceiling Tile: None Detected
(ND)
02 Room 4117A Ceiling Tile: ND
03 Room 4102 Ceiling Tile: ND
Tan 8”x8” Ceramic Tile with Tan
Grout and Tan Mortar
Room 4121 Room 4121
4117A
Ceramic Tile: ND Grout: ND
02 Room 4118 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Room 4117A Ceramic Tile: ND
Grout: ND Mortar: ND
Gray Undersink Coating
Room 4121 Room 4121
4117A
Undersink Coating: ND
02 Room 4119 Undersink Coating: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
03 Room 4123
Undersink Coating: ND
Gray 4” Cove Base and Yellow Mastic
Room 4121
Room 4121 4117A 4108A
Corridor
Cove Base: ND Mastic: ND
02 Room 4119 Cove Base: ND
Mastic: ND
Corridor Outside
Room 4116 Cove Base: ND
Mastic: ND
Yellow Carpet Glue
Room 4121
Room 4121 4117A
Office 1 Office 2 Office 5
Corridor
Carpet Glue: ND
02 Room 4119 Carpet Glue: ND
Corridor Outside
Room 4116 Carpet Glue: ND
01 White Wall Board Room 4121
Room 4121
Wall Board: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
02 Room 4123
Wall Board: ND
03 Room 4116 Wall Board: ND
Wall Board Brown Glue Pod
Room 4121
Room 4121
Glue Pod: ND
02 Room 4123 Glue Pod: ND
03 Room 4116 Glue Pod: ND
Brown 4” Cove Base and yellow mastic (1) and brown mastic (2)
Room 4120
Room 4120 Room 4110C
Cove Base: ND Mastic 1: ND Mastic 2: ND
02 Room 4120 Cove Base: ND
Mastic: ND
03 Room 4120 Cove Base: ND Mastic 1: ND Mastic 2: ND
2’x4’ Pinholes and Craters Ceiling Tile
Room 4120 Room 4120
Office 1 Corridor
Ceiling Tile: ND
02 Room 4116 Ceiling Tile: ND
03 Office 1 Ceiling Tile: ND
Tan, Brown, and
White 1”x1” Ceramic Tile and tan grout, yellow adhesive, and beige paper
Restroom 2
Restroom 1 Restroom 2
Ceramic Tile: ND Grout: ND
Adhesive: ND Paper: ND
02 Restroom 1
Ceramic Tile: ND Grout: ND
Adhesive: ND Paper: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
03 Restroom 2
Ceramic Tile: ND Grout: ND
Adhesive: ND Paper: ND
Brown 1”x1” Ceramic Tile with tan grout, white adhesive, and gray mortar
Restroom 2
Restroom 1 Restroom 2
Ceramic Tile: ND Grout: ND
Adhesive: ND Mortar: ND
02 Restroom 1
Ceramic Tile: ND Grout: ND
Adhesive: ND Mortar: ND
03 Restroom 2
Ceramic Tile: ND Grout: ND
Adhesive: ND
2’x2’ Rough
Texture Ceiling Tile
Room 4119 Room 4119
Ceiling Tile: ND
02 Room 4117 Ceiling Tile: ND
03 Room 4123 Ceiling Tile: ND
Gray Duct Sealant
Room 4118 Room 4118 4110B
Duct Sealant: ND
02 Room 4117 Duct Sealant: ND
03 Room 4117 Duct Sealant: ND
Black Vibration Dampener
Room 4113 Room 4118
Room 4110B
Vibration Dampener: ND 02 Room 4110B Vibration Dampener: ND 03 Room 4110B Vibration Dampener: ND
Red Fire Caulk
Room 4118 Room 4118
Office 1 Office 2 Office 5 Corridor
Fire Caulk: ND
02 Room 4117 Fire Caulk: ND
03 Office 2 Fire Caulk: ND
16 01 Room 4117B Room 4177B Room 4113J
Cove Base: ND Mastic: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Black 4” Cove
Base and Yellow Mastic
Room 4123A Room 4123A Room 4123B Room 4109B Room 4109C Room 4110B
Corridor
Cove Base: ND Mastic: ND
Corridor Near Main
Entrance Cove Base: ND
Mastic: ND
01 Gray with White and Gray Feather Pattern 12”x12” Vinyl Tile and Yellow Mastic
Room 4117B Room 4177B Room 4113J Room 4123A Room 4123B
4108A 4110B
Tile: ND Mastic: ND
02 Room 4123A Tile: ND
Mastic: ND
03 Room 4108 Tile: ND
Mastic: ND
01 Gray/Blue 4” Cove
Base and Yellow Mastic
Room 4116 Room 4116
Office 1
Cove Base: ND Mastic: ND
02 Room 4114 Cove Base: ND
Mastic: ND
2’x4’ Pinholes
Ceiling Tile
Room 4113 Room 4113
Room 4109B
Ceiling Tile: ND
02 Room 4108 Ceiling Tile: ND
03 Room 4109 Ceiling Tile: ND
2’x4’ Pinholes and
Small Fissures Ceiling Tile
Room 4113 Room 4113
Corridor
Ceiling Tile: ND
Corridor Outside
Room 4108 Ceiling Tile: ND
Corridor Outside
Room 4102 Ceiling Tile: ND
01 Warnock Hersey Metal Fire Door –
Brown Core Material
Room 4123A Room 4113J Room 4123A Room 4108A
Fire Door: ND 02 Room 4113 Fire Door: ND
03 Room 4113 Fire Door: ND
Blue and White 1”x1” Ceramic Floor Tile with Gray Grout and
Gray Mortar
Restroom 3
Restroom 3
Ceramic Tile: ND Grout: ND
Mortar: 0.25% Chrysotile by Point
Count
02 Restroom 3
Ceramic Tile: ND Grout: ND
Mortar: 0.0% by Point Count
03 Restroom 3
Ceramic Tile: ND Grout: ND
Mortar: 0.0% by Point Count
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Light Blue 6”x4” Ceramic Tile with Gray Grout and
Gray Mortar
Restroom 3
Restroom 3
Ceramic Tile: ND Grout: ND Mortar: ND
02 Restroom 3 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Restroom 3 Ceramic Tile: ND
Grout: ND Mortar: ND
Tan and Yellow 1”x1” Ceramic Floor Tile with Gray Grout and
Gray Mortar
Restroom 4
Restroom 4
Ceramic Tile: ND Grout: ND
02 Restroom 4
Ceramic Tile: ND Grout: ND
Mortar: 0.25% Chrysotile by Point
Count
03 Restroom 4
Ceramic Tile: ND Grout: ND
Mortar: 0.50% Chrysotile by Point
Count
Light Tan 6”x4” Ceramic Tile with Gray Grout and
Gray Mortar
Restroom 4
Restroom 4
Ceramic Tile: ND Grout: ND Mortar: ND
02 Restroom 4 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Restroom 4 Ceramic Tile: ND
Grout: ND Mortar: ND
Blue 1”x1” Ceramic Tile with Gray Grout and White Mortar
Restroom 4
Restroom 4
Ceramic Tile: ND Grout: ND Mortar: ND
02 Restroom 4 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Restroom 4 Ceramic Tile: ND
Grout: ND Mortar: ND
01 Gray Mudded Pipe Insulation Fitting
Joints on Fiberglass
Insulated Lines
Restroom 1 Restroom 1 Restroom 2 Room 4108A Room 4108
Office 7 Room 4109
Corridor
Mudded Fitting: ND
02 Room 4108 Mudded Fitting: ND
03 Room 4109 Mudded Fitting: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Drywall (Unfinished, no joint compound)
Office 5 Room 4108
Office 5 Office 7
Room 4105 4109B 4109C
Drywall: ND
02 Room 4105 Drywall: ND
03 Room 4106 Drywall: ND
2’x2’ Pinholes and Crates Ceiling Tile
Office 2 Office 2 Office 5
Ceiling Tile: ND
02 Office 5 Ceiling Tile: ND
03 Office 5 Ceiling Tile: ND
Navy Blue 4” Cove Base with Yellow
Mastic
Office 2 Office 2
Restroom 7 Corridor
Cove Base: ND Mastic: ND
Corridor Outside
Office 1 Cove Base: ND
Mastic: ND
03 Restroom 7 Cove Base: ND
Mastic: ND
Black Window Sill
– 3 Layers (1 – black, 2 - gray, and 3 – brown/white)
Room 4108
Room 4108
Layer 1: ND Layer 2: ND Layer 3: ND
02 Room 4105 Layer 1: ND Layer 2: ND Layer 3: ND
03 Room 4107 Layer 1: ND Layer 2: ND
Dark Gray 4” Cove Base and Yellow
Mastic
Room 4108 Room 4108
Office 5 Room 4101
Cove Base: ND Mastic: ND
02 Room 4106 Cove Base: ND
Mastic: ND
03 Room 4101 Cove Base: ND
Mastic: ND
01 Gray with Green, Red, and Blue Specs 12”x12” Vinyl Tile and Black Mastic
Room 4108
Room 4108
Tile: ND Mastic: ND
02 Room 4108 Tile: ND
Mastic: ND
03 Room 4108 Tile: ND
34 01 Room 4108 Room 4108 Drywall: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Drywall and White Joint Compound
Corridor Joint Compound: ND
02 Room 4108 Drywall: ND
Joint Compound: ND
03 Corridor Drywall: ND
Joint Compound: ND
White 6”x4” Ceramic Tile with
Tan Grout and Whtie Adhesive
Room 4108
Room 4108
Ceramic Tile: ND Grout: ND
Adhesive: ND
02 Room 4108 Ceramic Tile: ND
Grout: ND Adhesive: ND
03 Room 4108 Ceramic Tile: ND
Grout: ND Adhesive: ND
Black Undersink
Coating
Room 4108 Room 4108
Undersink Coating: ND
02 Room 4101 Undersink Coating: ND
03 Room 4105 Undersink Coating: ND
Black 4” Cove
Base and Brown Mastic
Corridor Outside Restroom `
Office 7 Corridor
Cove Base: ND Mastic: ND
Corridor Outside
Room 4110 Cove Base: ND
Mastic: ND
Corridor Outside
Room 4108 Cove Base: ND
Mastic: ND
1’x1’ Paper Ceiling Tile
Room 4101 Room 4101
Ceiling Tile: ND 02 Room 4102 Ceiling Tile: ND 03 Room 4102 Ceiling Tile: ND
1’x1’ Holes Ceiling Tile
Room 4101 Room 4101
Ceiling Tile: ND 02 Room 4102 Ceiling Tile: ND 03 Room 4102 Ceiling Tile: ND
White 4”x4” Ceramic Tile with White Grout and White Adhesive
Room 4101 Room 4101
Ceramic Tile: ND Grout: ND
Adhesive: ND
02 Room 4102 Ceramic Tile: ND
Grout: ND Adhesive: ND
03 Room 4105 Ceramic Tile: ND
Grout: ND Adhesive: ND
01 Yellow Carpet Mastic (top layer), Tan with Brown Streaks 9”x9” Vinyl Tile
Corridor Outside Room 4103 Room 4101
Mastic 1: ND Tile: 6% Chrysotile
Mastic: 2% Chrysotile
02 Room 4101 Mastic 1: ND
Tile: Not Analyzed – 1st
Sample Positive
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
and Black Tile Mastic
Corridor (Outside 4101, 4102, 4103)
Mastic: Not Analyzed – 1st Sample Positive
03 Room 4104
Mastic 1: ND Tile: Not Analyzed – 1st
Sample Positive Mastic: Not Analyzed –
1st Sample Positive
Blue 7”x7” Ceramic Tile with Gray Grout and
Gray Mortar
Restroom 7
Restroom 7
Ceramic Tile: ND Grout: ND Mortar: ND
02 Restroom 7 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Restroom 7 Ceramic Tile: ND
Grout: ND Mortar: ND
2’x2’ Pinholes Ceiling Tile
Restroom 7 Restroom 7 Restroom 8
Ceiling Tile: ND 02 Restroom 8 Ceiling Tile: ND 03 Restroom 8 Ceiling Tile: ND
Maroon 7”x7” Ceramic Tile with Gray Grout and
Gray Mortar
Restroom 8
Restroom 8
Ceramic Tile: ND Grout: ND Mortar: ND
02 Restroom 8 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Restroom 8 Ceramic Tile: ND
Grout: ND Mortar: ND
Maroon 4” Cove Base and Yellow
Mastic
Restroom 8
Restroom 8
Cove Base: ND Mastic: ND
02 Restroom 8 Cove Base: ND
Mastic: ND
03 Restroom 8 Cove Base: ND
Mastic: ND
Painted Drywall
Ceiling and White Joint Compound
Restroom 7 Restroom 7 Restroom 8 Mechanical
Room (Above
Acoustical Drop Ceiling Tile in Restrooms)
Drywall: ND Joint Compound:
0.75%% Chrysotile 02 Restroom 8 Drywall: ND
03 Restroom 8 Drywall: ND
01 Drywall (No Joint Compound)
Between Wood Sheeting
Mechanical Room
Mechanical Room
Drywall: ND 02 Mechanical Room Drywall: ND
03 Mechanical Room Drywall: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Light Gray with Gray Feathering
12”x12” Vinyl Tile and Yellow Mastic
Room 4110
Room 4110 Room 4110B
Tile: ND Mastic: ND
02 Room 4110 Tile: ND
Mastic: ND
03 Room 4110 Tile: ND
Mastic: ND
Yellow, Orange, Purple 12” x 12” Vinyl Tile System and Yellow Mastic
Room 4110
Room 4110
Tile: ND Mastic: ND
02 Room 4110 Tile: ND
Mastic: ND
03 Room 4110 Tile: ND
Mastic: ND
Ceiling Tile Brown Glue Pod
Room 4110
Room 4110
Ceiling Tile: ND Glue Pod: ND
02 Room 4110 Ceiling Tile: ND Glue Pod: ND
03 Room 4110 Ceiling Tile: ND Glue Pod: ND
Tan/White 2’x2’ Fiber Board
Room 4110 Room 4110
Fiberboard: ND 02 Room 4110 Fiberboard: ND 03 Room 4110 Fiberboard: ND
Red 6”x6” Ceramic Floor Tile with Gray
Grout and White Mortar
Room 4109
Room 4109
Ceramic Tile: ND Grout: ND
Mortar: 0.75% Chrysotile by Point
Count
02 Room 4109
Ceramic Tile: ND Grout: ND
Mortar: 0.25% Chrysotile
03 Room 4109
Ceramic Tile: ND Grout: ND
Mortar: 0.25% Chrysotile
Hard Layered Plaster (White Skim Coat and Gray Plaster)
Room 4109
Room 4109
Skim Coat: ND Plaster: ND
02 Room 4109 Skim Coat: ND
Plaster: ND
03 Room 4109 Skim Coat: ND
Plaster: ND
01 White Building Caulk (Interior Wall Expansion
Joint Caulk)
Room 4108 Room 4108
Room 4110A Room 4106
Caulk: ND 02 Room 4110A Caulk: ND
03 Room 4106 Caulk: 2% Chrysotile
01 Wood Panel
Warnock Hersey Office 4
Office 4 Fire Door: ND
02 Office 4 Fire Door: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Fire Door – White
Core Material Office 4 Fire Door: ND
Brown 1”x1” Ceramic Tile with Gray Grout and Tan Adhesive
Corridor by Main Entry
Corridor
Ceramic Tile: ND Grout: ND
Adhesive: ND
Corridor by Main
Entry
Ceramic Tile: ND Grout: ND
Adhesive: ND
Corridor by Main
Entry
Ceramic Tile: ND Grout: ND
Adhesive: ND
Tan 2”x2” Ceramic Tile with Tan
Grout and Gray Mortar
Corridor by Main Entry
Corridor by Main Entry Corridor by
Main Entry
Ceramic Tile: ND Grout: ND
Adhesive: ND
Corridor by Main
Entry
Ceramic Tile: ND Grout: ND Mortar: ND
Corridor by Main
Entry
Ceramic Tile: ND Grout: ND Mortar: ND
Floor Leveling Compound (2
Layers: 1 – White and 2 – Gray)
Corridor Outside Room 4119
Corridor
Leveling 1: ND Leveling 2: ND
Corridor Outside
Room 4119 Leveling 1: ND Leveling 2: ND
Corridor Outside
Room 4119 Leveling 1: ND Leveling 2: ND
Gray/Red EFIS
Exterior, Outside Room 4108
Exterior
EFIS: ND
Exterior, Outside
Room 4103
EFIS: ND
Exterior, Outside
Room 4107
EFIS: ND
Gray Window Frame Caulk
(Exterior)
Exterior, Outside Room 4108
Exterior (On Windows)
Caulk: ND
Exterior, Outside
Room 4116 Caulk: 2%
Exterior, Outside
Room 4117
Caulk: Not Analyzed – Previous Sample
Positive
Roofing System (2
Felt on Foam Layers: 1 –
Brown/Yellow and 2 – Yellow/Gray)
North Roof, Middle
Exterior
Felt on Foam 1: ND Felt on Foam 2: ND
North Roof, North
Side Felt on Foam 1: ND Felt on Foam 2: ND
North Roof, West
Side Felt on Foam 1: ND Felt on Foam 2: ND
04 North Roof, East Felt on Foam 1: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Felt on Foam 2: ND
Gray/Yellow Roofing System
South Roof, Middle
Exterior
Roof: ND
02 South Roof, West Roof: ND
South Roof, Northwest
Roof: ND
04 Gym Roof Roof: ND
Black Roof Tar Patch
South Roof, West Roof Systems
(Exterior)
Roof Tar: ND 02 Middle, East Roof Tar: ND 03 North Roof, West Roof Tar: ND
Black Roof Caulk South Roof, West
Roof Systems (Exterior)
Roof Caulk: ND 02 Cafeteria Roof Roof Caulk: ND 03 North Roof, West Roof Caulk: ND
Gray Roof Caulk
North Roof, East
Roof Systems (Exterior)
Roof Caulk: ND
North Roof, Skylight Roof Caulk: ND
Cafeteria Roof, North Roof Caulk: ND
Dark Gray Wall Expansion Joint Caulk (Exterior) at EIFS
Exterior, SW Side
Exterior (at EFIS)
Caulk: ND
Exterior, South
Side Caulk: ND
Exterior, North
Side Caulk: 2% Chrysotile
White Building Caulk (Exterior)
Exterior, Outside Room 4322
Exterior
Caulk: ND
Exterior, Outside
Room 4323 Caulk: ND
Exterior, Outside
Room 4323 Caulk: ND
HA = Homogeneous Area ND = None Detected Bold indicates ACM
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
Library/Office Addition (260402)
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Drywall and White Joint Compound
Room 4111
Room 4111 Room 4322
Drywall: None Detected
(ND)
Joint Compound: ND
02 Room 4111 Drywall: ND
Joint Compound: ND
03 Room 4322 Drywall: ND
Joint Compound: ND
Fiberglass Panel Beige Glue Pod
Room 4111 Room 4111
Glue Pod: ND 02 Room 4111 Glue Pod: ND 03 Room 4111 Glue Pod: ND
Blue 4” Cove Base and Beige Mastic
Room 4111 Room 4111 Room 4111A Room 4111B Room 4111C
Cove Base: ND Mastic: ND
02 Room 4111 Cove Base: ND
Mastic: ND
03 Room 4111 Cove Base: ND
Mastic: ND
Clear Carpet Glue
Room 4111 Room 4111 Room 4111A Room 4111C Room 4320 Room 4322 Room 4323
Office Corridor
Carpet Glue: ND
02 Room 4320 Carpet Glue: ND
03 Room 4322 Carpet Padding: ND
Black Vibration Dampener
Room 4111A Room 4111A Room 4111B
Vibration Dampener: ND 02 Room 4111B Vibration Dampener: ND 03 Room 4111B Vibration Dampener: ND
Red Fire Caulk
Room 4111B Room 4111A Room 4111B Room 4320 Room 4320A Room 4322 Room 4323
Office Corridor Restroom 5 Restroom 6
Office 6
Fire Caulk: ND
02 Room 4111A Fire Caulk: ND
03 Office Corridor Fire Caulk: ND
Gray Undersink Coating
Room 4111C Room 4111C
Undersink Coating: ND 02 Room 4111C Undersink Coating: ND 03 Room 4111C Undersink Coating: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Large and Small Pinholes 2’x2’
Ceiling Tile
Room 4111 Room 4111 Room 4111C Room 4320 Room 4320A Room 4322 Room 4323
Office Corridor Restroom 5 Restroom 6
Office 6
Ceiling Tile: ND
02 Room 4320 Ceiling Tile: ND
03 Office 6 Ceiling Tile: ND
01 Gray with red, White, and Blue Specs 12”x12” Vinyl Tile and
Tan/Yellow Mastic
Room 4320A Room 4320A Office Corridor
Restroom 5 Restroom 6
Office 6
Vinyl Tile: ND Mastic: ND
02 Office 6 Vinyl Tile: ND
Mastic: ND
03 Office Corridor Vinyl Tile: ND
Mastic: ND
Gray 4” Cove Base and Beige Mastic
Room 4320A Room 4320 Room 4320A Room 4322 Room 4323
Office Corridor Restroom 5 Restroom 6
Office 6
Cove Base: ND Mastic: ND
02 Restroom 6 Cove Base: ND
Mastic: ND
03 Room 4322 Cove Base: ND
Mastic: ND
01 Beige/Gray Mudded Pipe
Fitting Insulation on Fiberglass
Insulated Water Lines
Room 4320 Room 4320 Room 4320A Restroom 5 Restroom 6
Fitting: ND
02 Room 4320A Fitting: ND
03 Restroom 6 Fitting: ND
White Marble Window Sill
Room 4320 Room 4320 Room 4322 Room 4323
Sill: ND 02 Room 4322 Sill: ND 03 Room 4323 Sill: ND
01 Beige/Gray
Mudded Roof Drain Insulation
Room 4320 Room 4320
Fitting: ND 02 Room 4320 Fitting: ND 03 Room 4320 Fitting: ND
01 Roof Deck Drywall
Board (No Joint Compound)
Room 4320 Room 4320 Room 4320A
Office Corridor
Drywall: ND 02 Office 6 Drywall: ND 03 Office Corridor Drywall: ND
01 Warnock Hersey Wood Panel Fire
Door – White/Gold Core Material
Room 4320A Room 4320 Room 4320A Room 4322 Room 4323
Fire Door: ND
02 Room 4322 Fire Door: ND
03 Room 4320 Fire Door: ND
01 Gray Hard Duct
Sealant Room 4111C Room 4111C
Restroom 5 Duct Sealant: ND
02 Room 4111C Duct Sealant: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
03 Room 4111C Restroom 6 Duct Sealant: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
Gym Addition (260408)
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
2’x2’ Rough Texture Ceiling
Tile
Room 4126
Room 4126 Room 4127 Room 4136
Ceiling Tile: None Detected
(ND)
02 Room 4127 Ceiling Tile: ND
03 Room 4135 Ceiling Tile: ND
Gray 4” Cove Base and Beige Mastic
Room 4126
Room 4126 Room 4127 Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133
South Corridor Room 4134 Room 4135 Room 4136
Locker Room Custodial Closet 2
North Corridor
Cove Base: ND Mastic: ND
02 Room 4131 Cove Base: ND
Mastic: ND
Corridor Outside
Room 4135 Cove Base: ND
Mastic: ND
Tan 4”x4” Ceramic Tile with Gray
Grout and Gray Mortar
Room 4126
Room 4126 Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133 Room 4134 Room 4135 Room 4136
Ceramic Tile: ND Grout: ND
02 Room 4130 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Room 4134 Ceramic Tile: ND
Grout: ND Mortar: ND
04 01 Yellow Carpet Glue Room 4126
Room 4126 Room 4127 Room 4128 Room 4129
Carpet Glue: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
02 Room 4131
Room 4130 Room 4131 Room 4132 Room 4133
South Corridor Room 4134 Room 4135 Room 4136
Custodial Closet 2 Room 4138
North Corridor
Carpet Glue: ND
03 Room 4135 Carpet Glue: ND
Large and Small Pinholes 2’x4’
Ceiling Tile
Corridor Outside Room 4126
Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133 Room 4134
Custodial Closet 2 North Corridor
Ceiling Tile: ND
02 Room 4131 Ceiling Tile: ND
Corridor Outside
Room 4134 Ceiling Tile: ND
White/Gray Wallboard and
Yellow Glue Pod (Mastic)
Room 4128 Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133 Room 4134 Room 4135 Room 4136
Wall Board: ND Mastic: ND
02 Room 4131 Wall Board: ND
Mastic: ND
03 Room 4134 Wall Board: ND
Mastic: ND
Black Undersink Coating
Room 4128 Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133 Room 4134 Room 4135 Room 4136
Undersink Coating: ND
02 Room 4130 Undersink Coating: ND
03 Room 4136 Undersink Coating: ND
Tan 4”x4” Ceramic
Tile with Gray Grout and Gray
Mortar
South Corridor Vestibule
South Corridor North Corridor
Coat Room
Ceramic Tile: ND Grout: ND Mortar: ND
North Corridor
Vestibule Ceramic Tile: ND
Grout: ND
Coat Room between Rooms 4135 and 4136
Ceramic Tile: ND Grout: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
Maroon 4” Cove Base and Tan
Mastic
Staff Restroom Staff Restroom
Girls Restroom 1 Girls Restroom 2
Cove Base: ND Mastic: ND
02 Girls Restroom 1 Cove Base: ND
Mastic: ND
03 Girls Restroom 2 Cove Base: ND
Mastic: ND
01 Maroon 6”x6” Ceramic Tile with Gray Grout (Same Gray Mortar as HA
13)
Staff Restroom Staff Restroom
Girls Restroom 1 Girls Restroom 2
Ceramic Tile: ND Grout: ND
02 Girls Restroom 1 Ceramic Tile: ND
Grout: ND
03 Girls Restroom 2 Ceramic Tile: ND
Grout: ND
Blue 4” Cove Base and Tan Mastic
Boys Restroom 1
Boys Restroom 1 Boys Restroom 2
Cove Base: ND Mastic: ND
02 Boys Restroom 1 Cove Base: ND
Mastic: ND
03 Boys Restroom 2 Cove Base: ND
Mastic: ND
Blue 6”x6” Ceramic Tile with Gray Grout and
Gray Mortar
Boys Restroom 1
Boys Restroom 1 Boys Restroom 2
Ceramic Tile: ND Grout: ND Mortar: ND
02 Boys Restroom 1 Ceramic Tile: ND
Grout: ND Mortar: ND
03 Boys Restroom 2 Ceramic Tile: ND
Grout: ND Mortar: ND
01 2’x4’ Large and Small Pinholes, Smooth Surface
Ceiling Tile
Girls Restroom 1 Girls Restroom 1 Girls Restroom 2 Boys Restroom 1
Ceiling Tile: ND
02 Boys Restroom 1 Ceiling Tile: ND
03 Girls Restroom 2 Ceiling Tile: ND
Tan Feathered
Pattern 12”x12” Vinyl Tile and Black Mastic
Custodial Closet 1 Custodial Closet 1
Room 4135 Room 4136 Room 4139
Floor Tile: ND Mastic: ND
02 Room 4135 Floor Tile: ND
Mastic: ND
03 Room 4136 Floor Tile: ND
Mastic: ND
Brown 4” Cove Base and Beige
Mastic
Custodial Closet 1 Custodial Closet 1
Room 4135 Room 4136 Room 4139
Cove Base: ND Mastic: ND
02 Room 4135 Cove Base: ND
Mastic: ND
03 Room 4136 Cove Base: ND
Mastic: ND
18 01 Red Fire Caulk Custodial Closet 1 Custodial Closet 1
South Corridor Fire Caulk: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
South Corridor Outside Room
Fire Caulk: ND
South Corridor
Outside Custodial Closet 1
Fire Caulk: ND
Dark Brown 4” Cove Base and Yellow Mastic
Room 4136A Room 4135 Room 4135A Room 4136A Room 4136
Cove Base: ND Mastic: ND
02 Room 4136A Cove Base: ND
Mastic: ND
03 Room 4136 Cove Base: ND
Mastic: ND
Tan 12”x12” Ceramic Tile with
Brown Grout, Gray Mortar, and Black
Mastic
Room 4136A
Room 4135 Room 4135A Room 4136A Room 4136
Ceramic Tile: ND Grout: ND Mortar: ND Mastic: ND
02 Room 4136A
Ceramic Tile: ND Grout: ND Mortar: ND Mastic: ND
03 Room 4135A
Ceramic Tile: ND Grout: ND Mortar: ND Mastic: ND
Gray 6”x6”
Ceramic Tile with Gray Grout and
Gray Mortar (Same Gray
Mortar as HA 2, 9, 11, 13, and 20)
Locker Room
Locker Room
Ceramic Tile: ND Grout: ND
Gray Mortar: ND
02 Locker Room Ceramic Tile: ND
Grout: ND
03 Locker Room Ceramic Tile: ND
Grout: ND
Black Angled Cove Base and Yellow
Mastic
Room 4139
Room 4139
Cove Base: ND Mastic: ND
02 Room 4139 Cove Base: ND
Mastic: ND
03 Room 4139 Cove Base: ND
23 01 Room 4138 Room 4138 Vibration Dampener: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% / Type of Asbestos)HA #
SEQ.
02 Black Vibration
Dampener Room 4138 Room 4139 Vibration Dampener: ND
03 Room 4138 Vibration Dampener: ND
White/Gray Duct Sealant
Room 4138 Room 4138 Room 4139
Duct Sealant: ND 02 Room 4138 Duct Sealant: ND 03 Room 4138 Duct Sealant: ND
Gray Tectum Board
Room 4138 Room 4138 Room 4139
Tectum Board: ND 02 Room 4138 Tectum Board: ND 03 Room 4138 Tectum Board: ND
Yellow Backsplash Adhesive
Room 4130 Room 4128 Room 4129 Room 4130 Room 4131 Room 4132 Room 4133 Room 4134 Room 4135 Room 4136
Adhesive: ND
02 Room 4132 Adhesive: ND
03 Room 4134 Adhesive: ND
Hard Layered Plaster (White Finish Coat and Gray Base Coat)
South Corridor Near Room 4127
South Corridor Exterior
Finish: ND Base: ND
South Corridor
Near Room 4127 Finish: ND Base: ND
South Corridor
Near Room 4127 Finish: ND Base: ND
Exterior
(Outside Room 4108)
Finish: ND Base: ND
White Perlite Block Filler Insulation
Room 4114 Girls Restroom 1
Room 4133 Room 4132 Room 4131 Room 4130 Room 4129 Room 4128 Room 4126 Room 4139
Perlite: ND
02 Room 4118 Perlite: ND
03 Room 4126 Perlite: ND
04 Room 4139 Perlite: ND
May 11, 2026 | Terracon Project No. LD267060
Facilities | Environmental | Geotechnical | Materials
APPENDIX C
ASBESTOS ANALYTICAL LABORATORY DATA
Bulk Asbestos Analysis By Polarized Light Microscopy EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10106268Customer: Terracon 400 Ann St. NW Suite 204 Grand Rapids, MI 49504
Analysis:
Date Received:
Jeff Fusee
PLM
04/16/2026
Project: LD267060 Date Reported: 04/23/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
260401-01-01
10106268_0001
2'x4' Ceiling tile
None Detected 35% 35%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
260401-01-02
10106268_0002
2'x4' Ceiling tile
None Detected 35% 35%
Cellulose Mineral Wool
30% Other
Fibrous
Teased
White
Homogeneous
260401-01-03
10106268_0003
2'x4' Ceiling tile
None Detected 35% 35%
Mineral Wool Cellulose
30% Other
Fibrous
Teased
White
Homogeneous
260401-02-01 - A
10106268_0004
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Beige
Homogeneous ceramic tile
260401-02-01 - B
10106268_0208
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Tan
Homogeneous grout, no mortar
260401-02-02 - A
10106268_0005
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Beige
Homogeneous ceramic tile
260401-02-02 - B
10106268_0209
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Tan
Homogeneous grout
260401-02-02 - C
10106268_0210
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Tan
Homogeneous mortar
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (360)
Analyst Approved Signatory
Page 1 of 46P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10106268Customer: Terracon 400 Ann St. NW Suite 204 Grand Rapids, MI 49504
Analysis:
Date Received:
Jeff Fusee
PLM
04/16/2026
Project: LD267060 Date Reported: 04/23/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
260401-02-03 - A
10106268_0006
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Beige
Homogeneous ceramic tile
260401-02-03 - B
10106268_0211
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Tan
Homogeneous grout
260401-02-03 - C
10106268_0212
8"x8" Ceramic tile
None Detected 100% Other
Non-Fibrous
Crushed
Tan
Homogeneous mortar
260401-03-01
10106268_0007
Undersink coating
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
White
Homogeneous
260401-03-02
10106268_0008
Undersink coating
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous
260401-03-03
10106268_0009
Undersink coating
None Detected 5% Cellulose 95% Other
Non-Fibrous
Dissolved
White
Homogeneous
260401-04-01 - A
10106268_0010
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous cove base
260401-04-01 - B
10106268_0213
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (360)
Page 2 of 46P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10106268Customer: Terracon 400 Ann St. NW Suite 204 Grand Rapids, MI 49504
Analysis:
Date Received:
Jeff Fusee
PLM
04/16/2026
Project: LD267060 Date Reported: 04/23/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
260401-04-02 - A
10106268_0011
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous cove base
260401-04-02 - B
10106268_0214
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
260401-04-03 - A
10106268_0012
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Gray
Homogeneous cove base
260401-04-03 - B
10106268_0215
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic
260401-05-01
10106268_0013
Carpet glue
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous
260401-05-02
10106268_0014
Carpet glue
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous
260401-05-03
10106268_0015
Carpet glue
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous
260401-06-01
10106268_0016
Wall board
None Detected 50% 25%
Mineral Wool Cellulose
25% Other
Fibrous
Teased
White
Homogeneous
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.
Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.
Charmel Dozier (360)
Page 3 of 46P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888
EPA Method: 600/R-93/116 and
40 CFR, Part 763, Subpart E, App.E
Lab Order ID:Attn: 10106268Customer: Terracon 400 Ann St. NW Suite 204 Grand Rapids, MI 49504
Analysis:
Date Received:
Jeff Fusee
PLM
04/16/2026
Project: LD267060 Date Reported: 04/23/2026
Sample ID
Lab Sample ID
Description
Lab Notes Asbestos
Fibrous Components
Non-Fibrous Components Treatment
Attributes
260401-06-02
10106268_0017
Wall board
None Detected 50% 25%
Mineral Wool Cellulose
25% Other
Fibrous
Teased
White
Homogeneous
260401-06-03
10106268_0018
Wall board
None Detected 50% 25%
Mineral Wool Cellulose
25% Other
Fibrous
Teased
White
Homogeneous
260401-07-01
10106268_0019
Glue pod
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous
260401-07-02
10106268_0020
Glue pod
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous
260401-07-03
10106268_0021
Glue pod
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous
260401-08-01 - A
10106268_0022
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous cove base
260401-08-01 - B
10106268_0216
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Yellow
Homogeneous mastic 1
260401-08-01 - C
10106268_0217
4" Cove base
None Detected 100% Other
Non-Fibrous
Dissolved
Brown
Homogeneous mastic 2
Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request.