L7WA05 B91 Schematic.pdf
PDF 7 MB Posted
- Attached to
- FY26 L6WA18_B2390 Fall Protection
- Solicitation number
- FA857126Q0084
About this file
This document is a set of structural design drawings for a Fall Protection System at Robins Air Force Base. The project involves designing overhead fall protection equipment to protect workers during aircraft maintenance operations.
The design includes two primary system options: a mounted frame system with rigid posts and an overhead mobile anchor point system. The mounted frame option features structural steel columns (HSS 18.00x0.500) anchored to foundation footings, with horizontal bracing and support beams connecting to existing building structure. The system incorporates multiple platforms at different elevations to provide comprehensive fall protection coverage across the facility. The alternative mobile system utilizes an overhead swing arm track (28' or 30' diameter jib) mounted on a mobile base with a 492-foot reach capacity, providing flexibility for different work zones. Design loads include 100-125 PSF live loads, 90 MPH wind speed (115 MPH ultimate), and seismic design per ASCE 7-22 with a Seismic Design Category B classification. All structural steel conforms to AISC 360-10 specifications using ASTM A992 wide flange shapes and ASTM A500 hollow structural sections. Foundation details specify reinforced concrete with 4,500 PSI compressive strength, mechanical and adhesive anchors per ACI standards, and hot-dipped galvanized connections. The drawings include comprehensive foundation plans, framing elevation plans, connection details, and attachment specifications for both rigid post harness systems and jib arm alternatives, with capacity ratings up to 500 pounds on designated platforms.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
D R A F T
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
7/3 0/2
5 1
0:3 6:5
1 A M
FALL PROTECTION
SYSTEM
OVERVIEW PROPOSED
FALL PROTECTION
COMPONENTS
TAL-22010239-00
ADH
ROBINS AFB
JH
SS
10-24-25
SCHEMATIC
I:\P ro jec ts\
TA
L-
Ro bin s A
FB
\08
_G
EO
\11
_D ra wi ng s\0 1 D es ign
\01 E ng ine er ing
\S 2.d wg
S2.dwg
OVERHEAD SWING ARM TRACK
FALL PROTECTION
MOBILE RAINBOW
FITTING STAND
OVERHEAD MOBILE ANCHOR POINT
FOR WINGS S2 4Scale: N.T.S.
2" DIAMETER X 0.154"
THICK STEEL, SCHED 40
3"X0.5"
2 BOLTS E.A.
SWIVEL
LOCKING
8"Hx2"W
SWIVEL
LOCKING
8"Hx2"W
26"x9"
STEPS 9"
APART
3"x0.5" 2
BOLTS
E.A.
18.4° FROM
HORIZONTAL
PROPOSED COLUMN
BRACING FROM
EXISTING WING STAND
MEDIUM DUTY PLATE OR GRATE
WITH RATED 500 LB CAPACITY
DESIGN PER THE 2024 INTERNATIONAL BUILDING CODE AND UFC 03-301-01
1. LIVE LOADS (PER ASCE 7-22):
SLAB ON GRADE 125 PSF
TYPICAL FLOOR (ELEVATED LEVELS) 100 PSF
MECHANICAL AND LIGHT STORAGE 125 PSF
STAIRS AND EGRESS 100 PSF
2. WIND LOADS (PER ASCE 7-22):
INTERNAL WIND PRESSURE ______ 5 PSF
Vasd = 90 MPH/Vult = 115 MPH
ENCLOSURE CATEGORY: OPEN
EXPOSURE CATEGORY: C
3. EARTHQUAKE DESIGN DATA (PER ASCE 7-22):
SEISMIC IMPORTANCE FACTOR le = 1.25
MAPPED SPECTRAL RESPONSE ACCELERATIONS SS = 0.23
MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.084
SPECTRAL RESPONSE COEFFICIENT SDS = 0.19
SPECTRAL RESPONSE COEFFICIENT SD1 = 0.12
SITE CLASS D
SEISMIC DESIGN CATEGORY B
BASIC SEISMIC FORCE-RESISTING SYSTEMS: STEEL FRAMES NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE
RESPONSE MODIFICATION COEFFICIENT: R = 3
SEISMIC RESPONSE COEFFICIENT: Cs = 0.107
DESIGN BASE SHEAR V = 290 KIP
ANALYSIS DESIGN PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE
DESIGN CRITERIA:
1. CONCRETE (PER ACI 318-14):
ALL CONCRETE f ' c = 4,500 PSI (UON)
2. REINFORCING STEEL ASTM A615 GRADE 60
3. WELDED WIRE FABRIC ASTM A1064
4. STRUCTURAL STEEL (PER AISC 360-10):
WIDE FLANGE SHAPES ASTM A992
HSS RECTANGULAR ASTM A500, GR B, Fy = 46 KSI HSS ROUND ASTM A1085, GR A, Fy = 50 KSI
STEEL PIPES ASTM A53, GRADE B, TYPE S
CHANNELS ASTM A36
PLATES ASTM A36, UON
ANGLES ASTM A36
BOLTS ASTM A325 (3/4"Ø UON)
ANCHOR BOLTS ASTM F1554 (GRADE 36 UON)
ALL OTHER STEEL ASTM A36
5. WELDS (PER AWS D1.1) E70XX
6. HEADED SHEAR CONNECTORS 3/4" DIA. HSA
IN CONFORMANCE WITH AWS D1.1
MATERIAL PROPERTIES:
1. THE STRUCTURAL NOTES SHALL GOVERN IN MATTERS COVERED ON THE
STRUCTURAL DRAWINGS. SEE PROJECT SPECIFICATION AND OTHER
DRAWINGS FOR FURTHER REQUIREMENTS. TOTAL PROJECT DEFINITION
WILL BE PROVIDED BY COMBINING PROJECT SPECIFICATIONS,
ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL
DRAWING PACKAGES.
2. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE, UNLESS
OTHERWISE INDICATED. THEY DO NOT REPRESENT THE METHOD OF
CONSTRUCTION.
3. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT
THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. SUCH
MEASURES SHOULD INCLUDE, BUT NOT BE LIMITED TO TEMPORARY
BRACING AND SHORING OF DEAD LOADS, CONSTRUCTION LOADS, WIND
LOADS, ETC.
4. FOR TYPICAL DETAILS SHOWN BUT NOT BE REFERRED TO EXCEPT
HEREIN, CONFORM TO ALL OF THE REQUIREMENTS OF THESE DETAILS TO
THE SAME EXTENT AS IF REFERRED TO BY DETAIL NUMBER.
5. IF FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED, UNSTABLE OR
UNSUITABLE SOIL THE ENGINEER SHALL BE NOTIFIED.
6. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS OF EXISTING
SITE THAT ARE AFFECTED BY NEW WORK BEFORE PROCEEDING WITH
FABRICATION AND CONSTRUCTION.
7. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY ARCHITECTURAL,
MECHANICAL, ELECTRICAL, AND PLUMBING EQUIPMENT SHALL BE VERIFIED
WITH EQUIPMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL
WORK AFFECTED. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING DRAWINGS FOR OPENINGS, SLEEVES, ETC. NOT SHOWN ON THE
STRUCTURAL DRAWINGS.
GENERAL NOTES
1. STRUCTURAL STEEL SHALL CONFORM TO THE CURRENT EDITION OF THE AISC
STEEL CONSTRUCTION MANUAL (FOURTEENTH EDITION) INCLUDING AISC 360-10
(SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS) AND AISC 303-10 (CODE OF
STANDARD PRACTICE FOR STRUCTURAL STEEL BUILDINGS AND BRIDGES).
2. ALL WELDS SHALL BE PERFORMED IN ACCORDANCE WITH AWS D1.1 (LATEST
EDITION). ALL WELDS SHALL BE 3/16" MINIMUM FILLET WELDS UON OR AS
REQUIRED BY AISC.
3. FABRICATOR SHALL SUBMIT SHOP DRAWINGS TO STRUCTURAL ENGINEER FOR
REVIEW AND APPROVAL PRIOR TO THE START OF FABRICATION. ALL
STRUCTURAL STEEL SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED
SHOP DRAWINGS.
4. ALL SHOP CONNECTIONS SHALL BE WELDED. ALL FIELD WELDING SHALL BE
SHOWN ON THE SHOP DRAWINGS.
5. BOLTS AND BOLTED CONNECTIONS SHALL CONFORM TO THE REQUIREMENTS
OF THE LATEST EDITION OF THE SPECIFICATION FOR STRUCTURAL JOINTS USING
HIGH-STRENGTH BOLTS, AS APPROVED BY THE RESEARCH COUNCIL ON
STRUCTURAL CONNECTIONS (RCSC).
6. ALL BOLTS SHALL BE ASTM A325 .
7. WHERE CONNECTION DESIGN IS NOT PROVIDED IN THE DRAWINGS AND SHEAR
FORCES ARE GIVEN ON THE DRAWINGS. PLATE SIZES, ANGLE SIZES, NUMBER
AND SIZE OF BOLTS AND WELDS FOR CONNECTIONS SHALL BE DESIGNED BY THE
CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS OF PART 10 OF THE
FOURTEENTH EDITION OF THE AISC MANUAL FOR THE SHEAR FORCES SHOWN
ON THE DRAWINGS.
8. ALL STRUCTURAL STEEL MEMBERS, ANGLES, BARS, ANCHORS, ANCHOR BOLTS,
ETC. EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED AFTER
FABRICATION.
STRUCTURAL STEEL:
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
GENERAL NOTES
TAL-22010239-00
S000
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1. STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE ONCE IN
SERVICE. NO CONSIDERATION FOR STABILITY AND SHORING IS ASSUMED BY
THE STRUCTURAL ENGINEER DURING THE BUILDING PROCESS. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO ENSURE THE STABILITY AND SAFETY
OF THE STRUCTURE AND ITS COMPONENTS BY DETERMINING AND
IMPLEMENTING ERECTION PROCEDURES AND SEQUENCE OF CONSTRUCTION.
THIS INCLUDES TEMPORARY BRACING AND SHORING AS WELL AS SOIL
STABILIZATION AND PROTECTIVE MEASURES FOR ADJACENT EXISTING
CONSTRUCTION.
2. STRUCTURAL DRAWINGS AND SPECIFICATIONS SHALL BE UTILIZED
CONCURRENTLY WITH ARCHITECTURAL, SITE, AND ENGINEERING DRAWINGS
OF OTHER DISCIPLINES TO CONSULT INFORMATION NOT EXPLICITLY
INDICATED ON STRUCTURAL DRAWINGS.
3. CONTRACTOR SHALL VERIFY DIMENSIONS AND SITE CONDITIONS PRIOR TO
PROCEEDING WITH PROCUREMENT OF MATERIALS AND LABOR, FABRICATION,
AND CONSTRUCTION WORK. WHERE DISCREPANCIES EXIST, NOTIFY
ARCHITECT / ENGINEER OF SUCH DISCREPANCIES IN WRITING VIA A REQUEST
FOR INFORMATION / INTERPRETATION (RFI) BEFORE PROCEEDING WITH THE
WORK IN THE AFFECTED AREA IN QUESTION.
4. NO STRUCTURAL MEMBER OR COMPONENT SHALL BE CUT, NOTCHED, OR
OTHERWISE ALTERED UNLESS APPROVED IN WRITING BY STRUCTURAL
ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL
COSTS INCURRED BY STRUCTURAL ENGINEER FOR REVIEW OF SUCH
DEVIATIONS AND IMPLEMENTATION OF APPROPRIATE SOLUTIONS.
5. PRIOR TO COMMENCING WORK, THE GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR REVIEWING AND COORDINATING WITH THE SUB-
CONTRACTOR'S WORK INDICATED ON STRUCTURAL DRAWINGS WITH
ARCHITECTURE, SITE WORK, DELEATED COMPONENTS, AND THE WORK OF
OTHER ENGINEERING DISCIPLINES.
6. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS ARE REPRESENTATIVE
OF THE FINISHED STRUCTURE. THE STRUCTURAL ENGINEER SHALL NOT BE
IN RESPONSIBLE CHARGE AND CONTROL OF CONSTRUCTION MEANS,
METHODS, PROCEDURES AND CONSTRUCTION TECHNIQUES, AND JOBSITE
SAFETY. THIS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
7. THE STRUCTURAL ENGINEER SHALL NOT BE CONSTRUED AS HAVING
CONTROL, CHARGE, AND RESPONSIBILITY FOR THE ACTS AND OMISSIONS
AND FOR FAILURE OF THE CONTRACTOR, SUB- CONTRACTOR, AND OTHER
PERSONS PERFORMING THE WORK TO CARRY OUT SUCH WORK IN
ACCORDANCE WITH THE STRUCTURAL DRAWINGS AND COLLECTIVE
CONTRACT DOCUMENTS.
8. THE USE OF REPRODUCTIONS OF THESE STRUCTURAL DRAWINGS AND
SPECIFICATIONS AND USE OF ELECTRONIC FILES AND MODELS BY ANY
CONTRACTOR, SUBCONTRACTOR, ERECTOR, FABRICATOR OR MATERIAL
SUPPLIER IN LIEU OF PREPARATION OF SHOP DRAWINGS IS PROHIBITED
UNLESS PRIOR WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL
ENGINEER.
9. IN THE EVENT THERE IS CONFLICTING INFORMATION BETWEEN THE
DRAWINGS, SPECIFICATIONS AND LOCAL CODE APPLICATIONS OR ANY
OTHER CONTROLLING AUTHORITY, THE MOST STRINGENT CONDITION SHALL
APPLY.
1. DEFLECTION CRITERIA SHALL BE IN ACCORDANCE WITH DEFLECTION
AND DRIFT LIMITS SET HEREIN.
2. THE DEFLECTION LIMITS SHALL BE COORDINATED WITH THE
ARCHITECTURAL DRAWINGS BASED ON THE MATERIALS SPECIFIED BY
THE ARCHITECT. MATERIALS THAT REQUIRE DEFLECTION CRITERIA
THAT EXCEED THE LIMITS INDICATED HEREIN PER THE
MANUFACTURER'S AND/OR ARCHITECT'S RECOMMENDATIONS SHALL
MEET THE CRITERIA RECOMMENDED BY THE MANUFACTURER AND/OR
THE ARCHITECT.
3. DEFLECTION AND DRIFT LIMITS SHALL BE THE MORE STRINGENT OF
THE RATIO OR ABSOLUTE VALUES INDICATED HEREIN.
4. THE CONSTRUCTION OF THE BUILDING AND ITS COMPONENTS SHALL
BE CONFIGURED TO ACCOMMODATE THESE MOVEMENTS.
LIVE LOAD/WIND LOAD
TOTAL DEAD & LIVE LOAD
DEFLECTION LIMITS
ROOF STRUCTURE
EXTERIOR WALLS
WALLS RECEIVING STUCCO FINISH
OTHER WALLS NOT OTHERWISE SPECIFIED
PARAPETS
EXPOSED MASONRY
L/360
L/240
L/360
L/240
L/300
L/600
RATIO
ABSOLUTE
L/360 ---
FLOOR STRUCTURE & MEMBERS
SUPPORTING PARTITIONS
1. CHANGES AND/OR SUBSTITUTIONS BY THE CONTRACTOR TO THE STRUCTURAL
PLANS, DETAILS, MATERIALS, AND OTHER INFORMATION IN THE STRUCTURAL
DRAWINGS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW
AND APPROVAL.
2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO SUBMIT TO THE STRUCTURAL
ENGINEER THE APPROPRIATE DOCUMENTATION AND INFORMATION FOR REVIEW
INCLUDING BUT NOT LIMITED TO PRODUCT APPROVALS, SKETCHES, SIGNED AND
SEALED CALCULATIONS AS APPLICABLE, AND SPECIFIC PRODUCT MATERIAL
INFORMATION AS IT COMPARES TO THE PRODUCTS / MATERIALS SPECIFIED ON
THE STRUCTURAL DRAWINGS.
3. THE INCORPORATION OF CHANGES AND/OR SUBSTITUTIONS INCLUDING BUT
NOT LIMITED TO REVIEW, RE-DESIGN, RE-ANALYSIS, AND RE-DRAFTING INTO THE
STRUCTURAL DRAWINGS IS CONSIDERED AN ADDITIONAL SERVICE FOR THE
STRUCTURAL ENGINEER.
4. UNLESS OTHERWISE AGREED UPON BETWEEN THE CONTRACTOR AND
OWNER, THE CONTRACTOR SHALL PROVIDE AN APPLICABLE CREDIT TO THE
OWNER WHERE PROPOSED SUBSTITUTED MATERIALS AND LABOR ARE A
REDUCTION IN COST TO THE ORIGINALLY SPECIFIED ITEM.
GENERAL STRUCTURAL CRITERIA
DEFLECTION CRITERIA
SUBSTITUTIONS
1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS.
2. BASIS OF DESIGN ANCHOR PRODUCTS ARE THOSE INDICATED ON THE CONSTRUCTION
DOCUMENTS. SUBSTITUTION REQUESTS FOR ANCHORS OTHER THAN BOD ANCHORS
SHALL BE SUBMITTED TO THE EOR FOR WRITTEN APPROVAL. PROVIDE CALCULATIONS
SIGNED AND SEALED BY A PROFESSIONAL ENGINEER DEMONSTRATING THAT THE
SUBSTITUTED ANCHOR PRODUCT MEETS THE SPECIFIC PERFORMANCE REQUIREMENTS
OF THE BOD ANCHOR PRODUCT.
3. CONTRACTOR SHALL CONTACT EOR FOR WRITTEN APPROVAL PRIOR TO INSTALLING
POST-INSTALLED ANCHORS FOR MISSING OR MISPLACED CAST-IN-PLACE ANCHORS.
4. ANCHORS SHALL BE INSTALLED PER MANUFACTURER's WRITTEN INSTRUCTIONS.
CONTACT MANUFACTURER FOR TRAINING FOR PROPER ANCHOR INSTALLATION. SUBMIT
TRAINING CERTIFICATE DOCUMENTATION FOR WORKERS INSTALLING POST-INSTALLED
ANCHORS.
5. NO REINFORCEMENT SHALL BE CUT TO INSTALL POST-INSTALLED ANCHORS.
DEFECTIVE HOLES SHALL BE GROUTED WITH CEMENTITIOUS GROUT. CONTRACTOR
SHALL LOCATE EXISTING REINFORCEMENT BY NON-DESTRUCTIVE TESTING AND MARK
LOCATION ON SURFACE OF CONCRETE WITH NON-PERMANENT METHOD PRIOR TO
DRILLING.
6. PROVIDE CONTINUOUS SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE
ANCHORS, AS REQUIRED BY THE APPLICABLE EVALUATION REPORT.
7. ANCHORS SHALL BE HOT-DIPPED GALVANIZED OR STAINLESS STEEL.
CONCRETE MECHANICAL ANCHORS
1. MECHANICAL ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193 FOR CRACKED AND UNCRACKED
CONCRETE.
2. MECHANICAL ANCHORS SHALL NOT BE INSTALLED INTO CONCRETE THAT IS LESS THAN
7 DAYS OLD.
3. SCREW ANCHORS SHALL BE FOR INTERIOR USE ONLY.
4. BASIS OF DESIGN (BOD) IS HILTI KWIK HUS-EZ (ICC-ES ESR-3027).
CONCRETE ADHESIVE ANCHORS
1. ADHESIVE ANCHORS SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.4 AND ICC-ES AC308 FOR CRACKED AND UNCRACKED
CONCRETE.
2. ADHESIVE ANCHORS SHALL NOT BE INSTALLED INTO CONCRETE UNTIL IT HAS
REACHED 21 DAYS OR CONCRETE COMPRESSIVE STRENGTH HAS REACHED 75% OF THE
DESIGNED COMPRESSIVE STRENGTH.
3. INSTALLATION OF ADHESIVE ANCHORS INSTALLED HORIZONTALLY OR UPWARDLY
INCLINED SUPPORTING SUSTAINED TENSION LOADS SHALL BE PERFORMED BY
PERSONNEL HAVING PASSED A PERFORMANCE TEST IN ACCORDANCE WITH THE
ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM, OR EQUIVALENT.
4. BASIS OF DESIGN (BOD) IS HILTI HIT-HY 200 (ICC-ES ESR-3187) WITH ASTM A193 GR B7
OR ASTM F593 (AISI 316) ANCHORS.
ANCHORS
A
BCDEFG
H
/4
/2
8'
1/ 2"
8'
/2
/4
8'
/4
9' - 4 1/2"
21' - 6 1/2"
6' - 3 3/4"
4' - 8 1/2"
10' - 0 3/4"
2' - 8"
12' - 0"
66' - 8"
3' - 2 1/4"
3'
/2
6' - 2 1/4"
4'
/2
9"
5' - 4 3/4"
5' - 10 3/4"
1'
1'
3/
4"
3'
/4
14' - 9 1/4"
1'
/4
2' - 3 1/4"
PRODUCT MANUFACTURER
MOBILE
PLATFORM
AT WORK
PLATFORM
LEVEL
REACH LENGTH REQUIRED
EXOSPHERE ALL TERRAIN
4X4 FALL PROTECTION
ANCHOR SYSTEM
TUFF BUILT 7.5'
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
BAY T-6 KEY PLAN
TAL-22010239-00
S100
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/8" = 1'-0"
1 BAY T-6 FOUNDATION PLAN - KEY PLAN
B C
D E
F G
2 3 4
5 6 7 8 9 10 11
12 13
21 22
H
T A
IL
C
LE
A
R A
N C
E L
IN
E
8'
6' - 3"
7'
7'
8'
6' - 3"
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
FALL PROTECTION
REACH PLAN
TAL-22010239-00
S101
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
DASHED LINES REPRESENT RANGE
OF MOTION FOR 28' AND 30' Ø JIB
SYSTEM
SINGLE PONIT MOBILE
ANCHOR SYSTEM. SYSTEM TO
BE ON SLAB ON GRADE
SINGLE PONIT MOBILE
ANCHOR SYSTEM. SYSTEM
TO BE ON SLAB ON GRADE
BCDEFG
H 9' - 4 1/2" 21' - 6 1/2" 6' - 3 3/4"
4' - 8 1/2" 10' - 0 3/4"
2' - 8" 12' - 0"
8'
/2
/4
EXISITNG POST - TYP
PLANE OUTLINE - TYP
COL #2
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #4 OR MIRROR
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #3 OR MIRROR
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #1
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
4'
14' - 9 1/4"
2' - 3 1/4"
2'
4'
/2
6' - 2 1/4"
3'
/2
3' - 2 1/4"
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
MOUNTED FRAME
SYSTEM FOUNDATION
PLANS
TAL-22010239-00
S102
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/4" = 1'-0"
1 FOUNDATION PLAN - PLATFORM NORTH - MOUNTED FRAME
Hopgoodj Rectangle
Hopgoodj Rectangle
BCDEFG
H
9' - 4 1/2" 21' - 6 1/2" 6' - 3 3/4" 4' - 8 1/2"
10' - 0 3/4" 2' - 8"
12' - 0"
/4
/2
8'
(E) HSS5X5X1/2 COL - TYP
COL #6
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #8 OR MIRROR
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #7 OR MIRROR
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
COL #5
HSS18.00X0.500 COL
BOT OF COL EL: 0'-0"
1'
15' - 0" 3' - 11"
1'
1' - 2 1/4"
5/
8"
9"
5' - 4 3/4"
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
MOUNTED FRAME
SYSTEM FOUNDATION
PLANS
TAL-22010239-00
S103
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/4" = 1'-0"
1 FOUNDATION PLAN - PLATFORM SOUTH - MOUNTED FRAME
Hopgoodj Rectangle
BCDEFG
H
TAIL CLEARANCE LINE
HSS8X8X1/2
HSS8X8X1/2
H S
S 8X
8X 1/
H S
S 8X
8X 1/
HSS8X8X1/2
H S
S 8X
8X 1/2
COL #3 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 25'-9 5/8"
COL #4 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 28'-5"
9' - 4 1/2" 21' - 6 1/2" 6' - 3 3/4" 4' - 8 1/2" 10' - 0 3/4" 2' - 8" 12' - 0"
/2
/4
(E) 8" W SECTION
(E) 8" W SECTION
BM EL: [10'-0"]
(E
8" W
S E
C T
IO
N
B M
E L:
[1 0'
-0
(E) 8" W SECTION
BM EL: 10'-0"
(E) 8" W SECTION
BM EL: 10'-0"
(E
8" W
S E
C T
IO
N
B M
E L:
0'
-0
(E
8" W
S E
C T
IO
N
B M
E L:
0'
-0
(E) 8" W SECTION
BM EL: 10'-0"
(E
8" W
S E
C T
IO
N
B M
E L:
0'
-0
(E
8" W
S E
C T
IO
N
B M
E L:
0'
-0
BM EL: [10'-0"]
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
W 8X
COL #1
HSS18.00X0.500 COL
TOC EL: 28'-5"
COL #2
HSS18.00X0.500 COL
TOC EL: 28'-5"
HSS8X8X1/2
AT EXISTING COLUMNS
WITH NEW PROTECTION
SYSTEM COLUMNS,
REINFORCE CONNECTION
AT COLUMN WITH DETAIL /7 S302
3' - 10"
3/
4"
8 3/4"
2'
3/ 4"
4'
/4
1' - 1" 2' - 5 1/4"
2'
/2
1/
4"
HSS8x 8x
1/ 2 HSS8x8x1/2
H S
S 8x
8x 1/
HSS8x8x1/2
14' - 9 1/4"
5'
/2
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
MOUNTED FRAME
SYSTEM FRAMING PLAN
TAL-22010239-00
S201P
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/4" = 1'-0"
1 FRAMING PLAN - PLATFORM NORTH - MOUNTED FRAME
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
ABCDEFG
H
TAIL CLEARANCE LINE
H S
S 8X
8X 1/2
H
SS
8X 8X
1/
COL #4 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 28'-5"
COL #2
HSS18.00X0.500 COL
TOC EL: 28'-5"
COL #6
HSS18.00X0.500 COL
TOC EL: 28'-5"
COL #8 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 28'-5"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 5"x5" TUBE COL
TOC EL: 10'-0"
(E) 8" W SECTION
BM EL: [10'-0"]
(E
8" W
S E
C T
IO
N
B M
E L:
[1 0'
-0
(E
8" W
S E
C T
IO
N
B M
E L:
[1 0'
-0
(E) 8" W SECTION
BM EL: [10'-0"]
(E
8" W
S E
C T
IO
N
B M
E L:
[1 0'
-0
7'
COL #3 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 25'-9 5/8"
COL #7 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 25'-9 5/8"
AT EXISTING
COLUMNS WITH NEW
PROTECTION SYSTEM
COLUMNS,
REINFORCE
CONNECTION AT
COLUMN WITH DETAIL /7 S302
S302
S302
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
MOUNTED FRAME
SYSTEM FRAMING PLAN
TAL-22010239-00
S202P
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/4" = 1'-0"
1 FRAMING PLAN - PLATFORM CENTRAL - MOUNTED FRAME
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
ABCDEFG
H
/4
/2
HSS8X8X1/2
COL #8 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 28'-5"
COL #6
HSS18.00X0.500 COL
TOC EL: 28'-5"H
SS
8X
8X 1/
H S
S 8X
8X 1/2
COL #7 OR MIRROR
HSS18.00X0.500 COL
TOC EL: 25'-9 5/8"
COL #5
HSS18.00X0.500 COL
TOC EL: 28'-5"
H
SS8X8X1/2
AT EXISTING
COLUMNS WITH NEW
PROTECTION SYSTEM
COLUMNS,
REINFORCE
CONNECTION AT
COLUMN WITH DETAIL /7 S302
AT EXISTING
COLUMNS WITH NEW
PROTECTION SYSTEM
COLUMNS,
REINFORCE
CONNECTION AT
COLUMN WITH DETAIL /7 S302
4' - 2 1/2"
1/
4"
/4
1' - 1 3/4"
2'
5' - 1 3/4"
1'
/4
5' - 1 1/2"
7'
HSS8X8X1/2
S302
S302
S302
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
MOUNTED FRAME
SYSTEM FRAMING PLAN
TAL-22010239-00
S203P
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
1/4" = 1'-0"
1 FRAMING PLAN - PLATFORM SOUTH - MOUNTED FRAME
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
Hopgoodj Rectangle
1 8" TUBE SECTION BRACE PER PLAN
(E) HSS 5X5 COL
(E) W8 BEAM
ON SIDE
FACE OF
COL 6"X6"X1/2" THK BENT
PLATE. WIDTH OF
PLATE TO MATCH
FACE OF COLUMN
1/4
SECOND FLOOR PLAN
10' - 0"
6"X6"X1/2" THK BENT
PLATE. WIDTH OF
PLATE TO MATCH
FACE OF COLUMN
8" TUBE SECTION BRACE
1/4
(E) DECK OR
GRATING TO BE
REMOVED. PROVIDE
OPENING FOR RIGID
POST CLEARANCE
1/4
TYP BOTH
BMS
NOTE: POST EXTENDS TO SLAB ON GRADE.
FOR BASE PLATE AND ATTACHMENT INFO SEE
DETAIL
/3 S302
M A
X
SECOND FLOOR PLAN
10' - 0"
(E) FACE OF
W8 BEAM
(E) 7"
CHANNEL
BELOW
8" TUBE
SECTION
BRACE
1/2" THK BENT PLATE.
WIDTH OF PLATE TO
MATCH FACE OF
COLUMN
1/4
C
EXISITNG 11" W-SHAPE BEAM
10" LONG 1/2"
THK
STIFFENER
PLATE
SPACED 2'-0"
OC BOTH
SIDES
EXISITING 3" ANGLE
EXISITING 7" CHANNEL
1/4
6" LONG 1/2"
THK
STIFFENER
PLATE
SPACED 2'-0"
OC
1/2" THICK PLATE
CONT ALONG
CHANNEL
2 1/4" 3/8" STIFFENER
PLATE UNO AT
CONNECTIONS
EXTEND PLATE
AS REQUIRED AT
CONNECTIONS
COPE
CORNERS
3/16
3/16
WELD SIZE
EQUAL TO
ONE HALF
SHEAR PLATE
THICKNESS
3/16 MIN.
1/4
FIRST FLOOR PLAN
0' - 0"
SECOND FLOOR PLAN
10' - 0"
ABC
RIGID POST
HARNESS
ATTACHMENT BY
MANUFACTURER
RIGID POST
SUPPORT BEAM
TYPICAL SHEAR
CONNECTION - SEE
ADDITIONAL
DETAILS ON S303
1/2" THK
STIFFENER PLATE.
LENGTH TO MATCH
DEPTH OF
COLUMN. TOP AND
BOTTOM OF
ADJACENT BEAM
1/4
RIGID FRAME
POST - SEE PLAN
FOR SIZE
RIGID FRAME POST
SUPPORT BEAM -
SEE PLAN FOR
SIZE
PLANE WING
OUTLINE
RIGID POST FRAME
BRACE - SEE PLAN
25 FT MAX CANTILEVER SPAN
TOP OF FRAME PER PLAN
TOP OF WING ASSUMED
TO BE AT 16'-4" V.I.F.
FIRST FLOOR PLAN
0' - 0"
SECOND FLOOR PLAN
10' - 0"
ABC
RIGID POST
HARNESS
ATTACHMENT BY
MANUFACTURER
RIGID POST JIB
ARM BY
MANUFACTURER
TYPICAL SHEAR
CONNECTION - SEE
ADDITIONAL
DETAILS ON S303
1/2" THK
STIFFENER PLATE.
LENGTH TO MATCH
DEPTH OF
COLUMN. TOP AND
BOTTOM OF
ADJACENT BEAM
1/4
RIGID FRAME
POST - SEE PLAN
FOR SIZE
RIGID FRAME POST
SUPPORT BEAM -
SEE PLAN FOR
SIZE
PLANE WING
OUTLINE
RIGID POST FRAME
BRACE - SEE PLAN
TOP OF FRAME PER PLAN
TOP OF WING ASSUMED
TO BE AT 16'-4" V.I.F.
FIRST FLOOR PLAN
0' - 0"
SECOND FLOOR PLAN
10' - 0"
BASE PLATE WITH EPOXY
BOLTS - SEE ADDITIONAL
DETAILS
RIGID POST FRAME
BRACE - SEE 'RIGID
POST BRACE
ATTACHMENT' FOR
DETAILS
RIGID POST
SUPPORT BEAM
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
DETAILS
TAL-22010239-00
S301
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
3/4" = 1'-0"
1 POST BRACE TO EXISTING FRAME CONNECTION
3/4" = 1'-0"
2 RIGID POST BRACE ATTACHMENT 1" = 1'-0"
3 RIGID POST BRACE TO MAIN FRAME CONNNECTION
3/4" = 1'-0"
4 TYPICAL W-SECTION REINFORCEMENT
1" = 1'-0"
5 TYPICAL CHANNEL REINFORCEMENT
3/4" = 1'-0"
6 TYPICAL WEB STIFFENER PLATES
1/4" = 1'-0"
7 RIGID POST FRAME - ALT #1
1/4" = 1'-0"
8 RIGID POST FRAME - ALT #2
1/4" = 1'-0"
9 RIGID POST FRAME - ALT #3
0'-6"
0'-9"
1'-0"
1'-3"
"L"
SHEAR
PLATE LENGTH
1/4"
1/4"
1/4"
5/16"
SHEAR PLATE
THICKNESS
"N" No OF
7/8" DIA. A325
BOLTS
W8, W10
W12, W14
W16, W18
W21
NOMINAL
BEAM
DEPTH
BEAM CONNECTION SCHEDULE
FILLET
WELD SIZE
(E7OXX)
3/16"
3/16"
3/16"
1/4"
MAX.
ALLOWABLE END
REACTION (KIPS)
11.1
22.1
35.4
49.1
STL BEAM
SEE PLAN
"N
R O
W S
O
.C
. 1
/2
/2
"L
/2
COPE AS REQ'D AT BEAM FLANGES,
TOP & BOTTOM (REINF. WHERE
REQ'D TO SUSTAIN SPECIFIED
CAPACITY) T/STEEL
SEE PLAN
STL BEAM SEE PLAN
8"
5"
4"
2 1/2"
THRU BOLT
(SEE SCHED.)
SHEAR
PLATE (SEE
SCHED.) SEE SCHED.
0'-6"
0'-9"
1'-0"
1'-3"
1'-6"
1'-9"
2'-6"
"L"
PLATE LENGTH
0'-5"
0'-5"
0'-5"
0'-5"
0'-5"
0'-5"
0'-8"
"W"
PLATE WIDTH
PLATE
THICKNESS
W8, W10
W12, W14
W16
W18
W21
W24, W27
W36
NOMINAL
BEAM
DEPTH
CONNECTION PLATE
BEAM CONNECTION SCHEDULE
NOTE:
THESE SCHEDULES
REPRESENT THE
MINIMUM REQUIRED
CONNECTIONS PER
ENGINEER OF
RECORD. STEEL
FABRICATOR IS
RESPONSIBLE FOR
THE FINAL
CONNECTION
DESIGN AND
DETAILS BASED ON
REACTIONS SHOWN
ON FRAMING PLAN
"N"
# BOLT ROWS
1/4"
3/8"
3/8"
3/8"
1/2"
1/2"
1/2"
"C"
# BOLT COLUMNS
WELD
SIZE
3/16"
5/16"
5/16"
5/16"
3/8"
3/8"
3/8"
TUBE STEEL
COLUMN
3/8" CAP PL
SEE NOTE 1
*DOUBLE SHEAR
PLATE FOR W36
STEEL BEAM PER PLAN
NOTES:
1. PROVIDE STANDARD AISC
SHEAR CONNECTION FOR MAX.
UNIFORM LOAD TYP.
2. 3" BOLT SPACING DIMENSION IS
TYP. EXCEPT AS RECOMMENED
BY AISC FOR LARGER MEMBERS.
3. ALL BOLTS ARE TO BE 3/4" DIA.
A325 (U.N.O.) IN LONG SLOTTED
HOLES.
4. * INDICATES SPECIAL
PROVISIONS FOR W36
CONNECTIONS WHERE 3/4" DIA.
A325 THRU BOLTS ARE SUBJECT
TO DOUBLE SHEAR.
USE THRU PLATE
AT STEEL TUBE
OR PIPE COLS.
SEE NOTE 2"W"
6" "C" 2".
"L
/2
"N
R O
W S
O .C
/2
1/4"
TYP.
HSS COLUMN
PER PLAN
(8) 7/8" DIA. HAS-V
RODS W/ HILTI HIT-RE
500 V3 & 6" MIN EMBED
OR SIMPSON TITEN HD
ANCHORS W/ 6" EMBED
0.75" THICK
PL
(P
P R
O J E
C T
IO
N
E M
B E
D M
E N
T
IN
T O
C O
N C
R E
T E
T
O V
E R
A L
L L
E N
G T
H
D HEAVY HEX NUT
PLAIN WASHER
LEVELING NUT
L
H
K
W
ASTM F1554 GR55
THREADED ROD
SQUARE PLATE
NUT WELDED TO
SQUARE PLATE AND
THREADED ROD
3"
G R
IP 1
/2
D M
IN
P
BOLT PROJECTION
BOLT PROJECTION
LETTERED
DIMENSIONS
SQUARE
PLATE
W
T
HOLE. DIA
L
H
K
P (MINIMUM)
PLAIN WASHER
1/2" 5/8" 3/4" 7/8"
BOLT DIAMETER
1" 1 1/4" 1 1/2" 1 3/4"
3"
1/2" 1/2"
1"
1" 1"
5/8"
5/8"
3"2"2"2"
3/4"
3/4" 3/4"
LIGHT MEDIUM
5" 7"
3 1/2" 3 1/2"
3 1/2"
3/8"
7/8"
6"
4" 4 1/2" 5 1/2"
5 1/2"
6" 7"
7"
1 1/2" 1 1/2"
9"
7 1/2" 7 1/2" 7 1/2"
1 1/8" 1 3/8" 1 5/8" 1 7/8"
11" 11" 1'-4" 1'-4"
9 1/2" 9 1/2" 1'-1" 1'-1 1/2" 1'-7" 1'-7 1/2"
2 1/2"
1' - 2" 1' - 2"
11 3/4"
5/16"
BEVEL PERIMETER
OF PLATE WITH 45
DEGREE AND PAINT
YELLOW
EXISTING STEEL
COLUMN & CONNECTION
PER PLAN
1/2" STIFFENER PLATE
EACH SIDE
W-BEAM PER
PLAN
1/4
EXISTING WF PER PLAN
HSS BRACE PER PLAN
3/8" COLLAR PLATE
3' - 4"
1'
3/ 4"
P E
R P
LA
N 3/16" FILLET WELD
ALL AROUND AT
HSS KNIFE PLATE
3/8" THICK COLLAR TIE PLATE
HSS POST PER PLAN
HSS BRACE PER PLAN
PLATFORM
SIDE
AA
SECTION A-A
3/16"
L3X3X1/4 ANGLE AT
TOP AND BOTTOM OF
BRACE
3/16"
EXISTING WF CONNECTION TO HSS
COLUMNS
PL 1/2x8x6
(2) PL 1/2x8x3 AT EACH SIDE OF BEAM WEB
8" 3/16" 5"
3/16" 6"
3/16" 6"
3/16" 5"
4 3/4" 8 1/2" 4 3/4"
1'
/8
/8
1/
4"
3/ 4"
8"
1 1/2" 5" 1 1/2"
4 3/4" 8 1/2" 4 3/4"
/8
/8
1/
4"
8"
1 1/2" 5" 1 1/2"
3/4" THICK PLATES
FOR ATTACHMENT
BRACKET
(4) 15/16" Ø BOLT HOLES (TYP)
ATTACHMENT
BRACKET BY JIB
ARM MFR
HSS COLUMN
PER PLAN
/2
/8
/8
/8
/8
/8
/8
/8
/4
PJP
PJP
FRONT VIEW SIDE VIEW
1/
2"
/8
3 1/2"
(2) 11/16" Ø HOLES
2" 3/4"
6'
CAUTION: DO NOT SCALE DRAWINGS.
THIS REPRODUCTION MAY BE AT A SIZE DIFFERENT THAN ORIGINALLY DRAWN. EXP
ASSUMES NO RESPONSIBILITY FOR INCORRECT SCALING. UNAUTHORIZED REPRODUCTION
OR REUSE IS STRICTLY PROHIBITED. NOT PUBLISHED - ALL RIGHTS RESERVED. EXP
EXPRESSLY DISCLAIMS RESPONSIBILITY ARISING FROM UNAUTHORIZED USE OF THESE
DRAWINGS AND NOTES. AUTHORIZATION MUST BE IN WRITING.
© exp, 2023 www.exp.com exp
File Name:
Project Title
Dwg. Title
Project No.
Dwg. No. Rev. No.
No. Date
Professional Seal(s)
Date Printed:
Checked By:
Drawn By:
Approved By:
Revision t: +1.305.631.2208 201 Alhambra Circle, Suite 800 Coral Gables, FL 33134 t: +1.305.631.2208
U.S. Services Inc.
/2
4/
:0 4:
P
M
FALL PROTECTION
SYSTEM OPTIONS
DETAILS 2
TAL-22010239-00
S302
WS
ROBINS AFB
GR
MJR
10/24/2025
100% CD
\\X :\S pe ci fy F ile P at h in P ro je ct In fo rm at io n In st an ce P ro pe rt ie s
3/4" = 1'-0"
1 TYPICAL BEAM TO BEAM CONNECTION
3/4" = 1'-0"
2 TYPICAL BEAM TO COLUMN CONNECTION
3/4" = 1'-0"
3 TYPICAL BASE PLATE DETAILS
3/4" = 1'-0"
4 TYPICAL STIFFENER PLATE
3/4" = 1'-0"
5 OFF PLATFORM CONNECTION
1" = 1'-0"
7 EXISTING CONNECTION REINFORCEMENT
3/4" = 1'-0"
6 SWING ARM ATTACHMENT
File details come from the government source that posted it. Updated .