This is a specification document for prefabricated casework and lavatory fixtures for a project at Keller Elementary School, issued for bid on December 10, 2020, under project number TMP17103C. The document outlines detailed technical specifications for prefabricated casework installation, including requirements for cabinet assembly, component thicknesses, finishes, and work surfaces. Specific casework finishes are identified, including Wilsonart "Pewter Mesh" 4878-38 for cabinet exteriors and Wilsonart "Steel Mesh" 4879-38 for work surfaces, with PVC edge banding in colors to be selected by the architect from manufacturer standard lines. The specification also includes requirements for two-handle widespread lavatory faucets complying with ASME A112.18.1 and CSA B125.1 standards, with specific performance requirements of 1.20 gpm at 60 psi and features including solid brass construction, vandal-resistant handles, and interchangeable hot and cold stems.
The casework specifications require 3/4-inch thick core material for structural components, tops, sides, bottoms, doors, and drawer faces, with 1/2-inch material for drawer sides and bottoms. Work surface specifications call for 1 1/8-inch thick moisture-resistant particle board core with high-pressure decorative laminate surfaces and 3mm PVC edge banding. Installation requirements mandate that casework be installed plumb, level, true, and straight according to manufacturer instructions, with all items adjusted to operate smoothly and without warping or binding prior to owner use. The document specifies that the Delta lavatory faucet model includes a lifetime limited warranty on parts and finishes for residential applications or five years for commercial users, with specific dimensional requirements for deck thickness and center spacing of 6 to 16 inches.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Keller ROHS Casework Bid_Part4.pdf | ||
| Keller ROHS Casework Bid_Part5.pdf | ||
| Keller ROHS Casework Bid_Part2.pdf | ||
| Keller ROHS Casework Bid_Part1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION 123204
PREFABRICATED
CASEWORK
12/10/2020 ISSUED FOR BIDS TMP17103C
123204-6
2. Assemble components with clamps under controlled conditions in order to maintain cabinet squareness and properly set joints.
3. All joints shall be tight fitting and shall not rupture or loosen due to the following:
a. Dimensional changes in core materials.
b. Racking of casework during installation and shipping.
c. Normal use.
4. Base and tall cabinets shall have one piece side panels continuous to floor.
C. Back panels: Secure by one of the following methods:
1. Set securely in grooved channel along entire prerimeter and glued or screwed.
2. Securely screwed or doweled in place and captured and supported by mounting rails.
D. Mounting rails (stretchers) shall be fully concealed behind backs and sides. Rails shall be doweled into cabinet sides, sub-tops and/or bottoms.
1. Wall and tall cabinets shall incorporate two mounting rails.
a. Wall cabinets shall have rails positioned at top and bottom.
b. Tall cabinets shall have rails positioned at top and intermediate location.
2. Base units shall have rail positioned in the upper back area.
E. Base units, except sink base units, shall have a full sub-top. Sink base units shall be manufacturer’s standard reinforced open top with a removable split back panel.
F. Side panels and vertical dividers shall be bored to receive adjustable shelf supports at 32mm on center.
G. Drawers shall be full box design with a separate front, glued and doweled.
1. Four sides shall be glued and doweled together.
2. Bottom shall be screwed directly to bottom edges of the sides or set in grooves along all four sides and glued and screwed.
3. Front face shall be screwed to subface of full box.
H. Component minimum thicknesses shall be as follows:
1. Structural components shall be 3/4 inch thick core material.
2. Tops, sides and bottoms shall be 3/4 inch thick core material.
3. Back panels shall be 1/4 thick core material.
4. Mounting rails (stretchers) shall be 3/4 inch thick structural components.
5. Exposed cabinet backs shall be 3/4 inch decorative laminated backs in lieu of mounting stretchers.
6. Doors and drawer faces shall be 3/4 inch thick core material.
123204-7
7. Drawer sides and bottom shall be 1/2 inch thick core material.
8. Shelves shall be 3/4 inch thick up to 30 inches wide, 1 inch thick over 30 inches wide.
I. Component finishes shall be as follows:
1. Decorative Laminates:
a. Exposed Surfaces: High-pressure decorative laminate VGS (.028)
b. Sink Base Bottoms: High-pressure decorative laminate VGS (.028)
c. Semi-Exposed Surfaces: Thermally fused melamine laminate.
2. All laminated panels shall have balanced construction. Unfinished core stock surfaces, even on concealed surfaces (excluding edges), shall not be permitted.
a. Concealed Surfaces: High-pressure cabinet liner CLS (.020).
3. PVC Banding: Exposed and semi-exposed edges shall be PVC banding applied with hot melt adhesive. Thicknesses shall be as follows:
a. Door and drawer fronts shall be edged with 3mm PVC.
b. All other edges including exposed exterior cabinet members, top edges of drawer boxes, adjustable shelves, and interior panels shall be edged with 1 mm PVC.
2.6 WORK SURFACES
A. Countertop design shall be with separate rectangular backsplash
1. Continuous tops shall be joined with minimum number of splice joints and aligned with tight joint fasteners as required to provide a uniform and gapless joint.
B. Core: 1 1/8 inch thick moisture resistant partical board core.
C. Surface: High-pressure decorative laminate HGS (.048) and HGP (.039).
1. Front edges and exposed ends of work surfaces shall be edged with 3mm PVC
2. Backing sheet on underside shall be high-pressure backer BKL (.020).
123204-8
2.7 FINISHES
A. Cabinet exteriors:
1. Decorative laminate colors at cabinet exteriors, including door and drawer fronts, shall be selected by the Architect from any of the standard or premium solid color or pattern lines of Nevamar, WilsonArt, Formica and Pionite.
2. Provide the following:
a. Keller Elementary
Wilsonart “Pewter Mesh” 4878-38
3. PVC edges shall be selected by Architect from manufacturer’s full line of colors.
4. Exposed cabinet body edges shall be color matched to cabinet sides.
B. The underside of wall cabinets and the interior of open and glass door cabinets shall match the exterior cabinet colors. Cabinet interiors
1. The interior of closed-door cabinets and drawer boxes shall be manufacturer’s standard almond or white color.
2. PVC edges on adjustable shelves, drawer boxes and interior panel components shall match the color of the interior cabinet.
C. Cabinet hardware: Cabinet hardware finishes, including those for drawer pulls, drawer slides and hinges, shall be selected by Architect from manufacturer’s full lines.
D. Work surfaces: Colors shall be selected by Architect from any of the standard or premium solid color or pattern lines of Nevamar, WilsonArt, Formica and Pionite.
1. Provide the following:
a. Keller Elementary
Wilsonart “Steel Mesh” 4879-38
123204-9
PART 3 - INSTALLATION
3.1 EXAMINATION
A. Examine walls and floors with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work.
1. For the record, prepare written report, endorsed by Installer, listing conditions detrimental to performance of work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. Install according to manufacturer’s written instructions.
B. Erect casework, plumb, level, true and straight with no distortions. Shim as required. Where laminate clad casework abuts other finished work, scribe and cut to accurate fit.
3.3 ADJUSTING, CLEANING, AND PROTECTION
A. Adjust casework and hardware so that doors and drawers operate smoothly without warping or binding.
1. Verify that all locking devices operate properly.
B. Repair minor damage per manufacturer’s recommendations. Replace damaged items that cannot be restored to their original condition.
C. Protect prefabricated casework from damage, abuse, dust, dirt, stain, or paint. Do not permit use of casework during construction.
D. Clean Up: Remove all cartons, debris, sawdust, scraps, etc., and leave spaces clean and all prefabricated cabinets and countertops ready for Owner's use.
**END OF SECTION**
LAVATORY FAUCETS
■ Two Handle Widespread
Submitted Model No.:________________________________________________ Specific Features:___________________________________________________
STANDARD SPECIFICATIONS:
• 1.20 gpm @ 60 psi, 4.54 L/min @ 414 kPa laminar flow outlet
• Three hole mount
• Solid brass fabricated end valves and spout body
• Vandal resistant metal wrist blade handles. Red/blue colored graphics indicate hot/cold temperature
• Control mechanism shall be of the rotating cylinder type with stainless steel plate and 1/4 turn stops.
Replaceable non-metallic seats operate in stainless steel lined sockets
• Hot and cold stems are interchangeable
DSP-L-3579LF-WFHDF Rev. D
1 1/8" (29 mm)
Max. Deck Thickness
1 5/8" (42 mm) to 2 3/8"
(61 mm)
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.deltafaucet.com for finish options and product availability.
6"-16" (152 mm- 406 mm) centers
6 1/8" (156 mm)
11" (279 mm)
55 E. 111th Street, Indianapolis, Indiana 46280 350 South Edgeware Road, St. Thomas, ON N5P 4L1 © 2016 Masco Corporation of Indiana
1 3/8" (35 mm)
Dia.
3579LF-WFHDF
1/2"-14 NPSM
3579LF-WFLGHDF
7 5/16" (186 mm)
5 3/4" (146 mm)
2 1/8" (54 mm)
Dia.
1 1/4" (32 mm)
Dia.
8" (203 mm)
COMPLIES WITH:
• ASME A112.18.1 / CSA B125.1
| Indicates compliance to |
| ICC/ANSI A117.1 |
• Verified compliant with .25% weighted average Pb content regulations.
7 5/8" (194 mm)
3/8" O.D.
Copper Tubing Flexible Hose Connection
1 1/8" (29 mm)
Dia.
1"
(25 mm) Dia.
2" (51 mm)
Dia.
2" (51 mm)
Dia.
3 1/8" 79 mm) WARRANTY
• Lifetime limited warranty on parts (other than electronic parts and batteries) and finishes:
or, for commercial users, for 5 years from date of purchase.
• 5 year limited warranty on electronic parts (other than batteries); or, for commercial users, for 1 year from the date of purchase.
No warranty is provided on batteries.
lecol Cloud
File details come from the government source that posted it. Updated .