This document describes a federal contract solicitation for repair and renovation services. The solicitation seeks a firm fixed-price contract to repair and renovate an existing weapons facility building at Dannelly Field Air National Guard Base in Montgomery, Alabama. The scope of work includes removal and replacement of mechanical, electrical, and plumbing systems, installation of a new sprinkler system and roof, and interior renovations. There are also four bid options related to additional renovations and systems. The solicitation identifies sole source items that are required, such as controls and security systems. The contract period of performance is 425 days after notice to proceed. The solicitation targets small businesses and has a NAICS code of 236210 with a size standard of $39.5 million. The estimated value is between $5-10 million. The response due date is not provided. The soliciting agency is the Department of the Army Alabama Army National Guard.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Justification and Approval for Other Than Full and Open Competition
Sole Source Items within a Construction Project AFARS 5153.303-5
Contracting Activity: USPFO Alabama
Description of Action
Type of Action: Contract Type: Funding Type:
Description of Supplies/Service
Name and describe the required supplies/services
Authority Cited:
Reason for Authority Cited:
Estimated Value of Sole Source Components:
Efforts to Obtain Competition:
Actions to Increase Competition:
Market Research:
Interested Sources:
Other Facts:
Technical Certification:
I certify that the supporting data under my cognizance, which are included in the justification are accurate and complete to the best of my knowledge and belief.
Date:
Requirements Certification:
I certify that the supporting data under my cognizance, which are included in the justification are accurate and complete to the best of my knowledge and belief.
Date:
Contracting Officer Certification:
I certify that this justification is accurate and complete to the best of my knowledge and belief.
Date:
Approval:
Based on the foregoing justification, I hereby approve the procurement of on an other than full and open competition basis pursuant to the authority of:
subject to availability of funds, and provided that the services and property herein described have otherwise been authorized for acquisition.
| Dropdown1: [New Contract] |
| Dropdown2: [Firm Fixed Price] |
| Dropdown3: [SRM] |
| Text5: FAKZ172004 – Renovate Weapons Release, B1312 |
- Johnson Controls - The project will consist of installation of new heating, ventilating, and air conditioning systems throughout the facility. This will include new Direct Digital Controls.
- Monaco - The project includes the installing a fire suppression system to include a new fire alarm system.
- Stanley Best Access Systems-Locks - There will be a replacement of a majority of the interior and exterior doors that will require new cores/locks.
- Advantar - The project will be upgrading security measures to meet new requirements.
Text6: United States Code 3304(a)(1) as implemented in Federal Acquisition Regulation 6.302-1(a)(2)(ii)(B), Only one responsible source and no other supplies or services will satisfy agency requirements.
Text7: The 187th exclusively utilizes Johnson Controls for HVAC system's Direct Digital Controls. This is the only manufacturer that is utilized to allow for standardization and guaranteed interoperability. To build a structure that did not utilize this system would compromise the ability to control and monitor base utilities to reduce energy consumption to the maximum extent possible. Utilizing other manufacturers would necessitate the purchase of additional centralized monitoring systems for the the Weapons Release B1312 and Civil Engineering B1801.
The 187th currently uses the Monaco fire alarm system base wide. No other fire alarm transceiver will integrate with the Monaco system. Therefore the use of any other fire alarm transceiver would result in a substantial duplication of cost that will not be recovered through competition.
Stanley Best Access Systems-Locks: Master-keyed interchangeable lock cores manufactured by Stanley Best Access Systems are the standard for securing buildings at the 187FW. Lock handles and other devices aren't required to be Stanley Best Access Systems but all other devices must be fully compatible with MX-8 Best Access cores. Without Stanley Best Access System-Locks, the integrity of the security for our base would be compromised.
Advantor Security System – Air Force/NGB certified security system. Advantor is the only security system used on the 187FW facilities based on NGB selection process.
| Text8: A pre-solicitation notice was placed in beta.sam.gov in order to give contractors an early notification of this project. However, due to the proprietary nature of the Johnson Controls system, Monaco Fire alert system, Stanley Best Access Systems-Locks and Advantor Security System, no effort to compete with these band name requirements will be made. | |
| Text9: N/A | |
| Text10: A sources sought notice was placed in beta.sam.gov and 5 contractors expressed interest in this project. All contractors will include the Johnson Controls system, Monaco Fire alert system, Stanley Best Access Systems-Locks and Advantor Security System in their bid. | |
| Text11: | |
| Text12: The Johnson Controls system, Monaco Fire alert system, Stanley Best Access Systems - Locks and Advantor Security System are the only fire alarm transmitter that is compatible with the every occupied facility at the 187th. | |
| 2021-01-08T17:48:28-0600 | |
| SANDERS.ADAM.WAYNE.1110351549 |
| Text13: 08-Jan-2021 | |
| name 1: Maj Adam Sanders, BCE | |
| Position 1: | |
| 2021-01-08T17:49:11-0600 | |
| SANDERS.ADAM.WAYNE.1110351549 |
| 2021-01-12T15:53:21-0600 | |
| KAST.WILLIAM.CRAIG.1110182933 |
| Text19: Johnson Controls system, Monaco Fire alert system, Stanley Best Access Systems - Locks and Advantor Security System |
| Text20: United States Code 3304(a)(1) FAR 6.302-1(a)(2)(ii)(B), Only one responsible source and no |
other supplies or services will satisfy agency
| Text14: 12-Jan-2021 | |
| name 2: William Craig Kast | |
| Position 2: Contracting Officer | |
| Text15: 12-Jan-2021 | |
| name 3: William Craig Kast | |
| Position 3: Contracting Officer | |
| 2021-01-12T15:57:37-0600 | |
| KAST.WILLIAM.CRAIG.1110182933 |
| Text5000: 235000 |
| Dropdown999: [] |
File details come from the government source that posted it. Updated .