Jennings Elementary HL1224 Quincy MI C.pdf

PDF 283 KB Posted

Attached to
Quincy Jennings Elementary Outdoor Walk-in Cooler & Freezer
Solicitation number
RFP QCS 200000001780 1
Issued by
Michigan

About this file

This is a technical drawing and equipment approval document for Jennings Elementary School in Quincy, Michigan, prepared by Polar King, a refrigeration equipment manufacturer based in Fort Wayne, Indiana. The document presents design specifications for two refrigerated units: a walk-in cooler with an interior area of 171 square feet maintaining a temperature of 35°F and a walk-in freezer with an interior area of 82 square feet maintaining a temperature of -10°F. Both units feature 5-inch walls with 6-inch crowned roofs, keg duty floors, spring hinges, kick plates, shelving packages, exterior ramps, and anchors. The cooler operates on a 1.5 horsepower system with 20.6 MCA amperage, while the freezer operates on a 2.25 horsepower system with 27.2 MCA amperage. Both units utilize R-404A refrigerant and require 115/208-230 volt, 60 Hz, single-phase electrical supply.

The document is a design approval form dated May 5, 2020, drawn at a scale of 3/16 inch equals 1 foot, and requires signature approval from Jennings Elementary confirming acceptance of the design specifications, door locations and swing configurations, electrical requirements, and equipment placement. The cooler model is designated as FFAL-022Z-CFV, and both units include LED lighting and shelving configurations consisting of either 4-tier or 3-tier systems with dimensions of 36 inches by 79 inches by 79 inches. No pricing, contract terms, bid deadlines, or procurement-specific information is contained in this technical document.

View the file

Other files

File Type Posted
Hurricane Anchor Info with 1 Pic.pdf PDF
proposal form_5-18-20.pdf PDF
EFB documentation 1-17-19.pdf PDF
quincy specification_5-18-20.pdf PDF
SHEET 1 OF 1_5-18-20 (1).pdf PDF
Advertise for Bid_5-18-20.pdf PDF
instructions for bidding_5-18-20.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEVATION VIEW

PLAN VIEW

DRAWING APPROVAL

Jennings Elementary

Quincy, Michigan

R L E

F

R E

A

F

AutoCAD SHX Text THE REFRIGERATION SYSTEM SHOWN IS DESIGNED TO MAINTAIN INDICATED TEMPERATURE IF PRODUCT ENTERS WITHIN 10°F OF FINAL HOLDING TEMPERATURE. PLEASE CONTACT YOUR SALES REP IF INCOMING PRODUCT WILL BE ENTERING AT HIGHER TEMPERATURES. REFRIGERATION DESIGN IS SUBJECT TO CHANGE FOR IMPROVEMENTS.

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

BY:

AutoCAD SHX Text PLEASE INDICATE YOUR APPROVAL OF THIS DESIGN, THE DIMENSIONS, DOOR LOCATION/SWING, ELECTRICAL REQUIREMENTS, AND EQUIPMENT LOCATIONS BY SIGNING BELOW AND RETURNING TO POLAR KING.

AutoCAD SHX Text 5" WALLS / 4" NOTED 6" CROWNED ROOF 34" KEG DUTY FLOOR (2) SPRING HINGES (2) KICK PLATES SHELVING PACKAGE EXTERIOR RAMP (4) ANCHORS

AutoCAD SHX Text

HORSEPOWER:

AutoCAD SHX Text

REFRIGERANT:

AutoCAD SHX Text

ELEC. SUPPLY

AutoCAD SHX Text

AMPERAGE:

AutoCAD SHX Text

CYCLE:

AutoCAD SHX Text

PHASE:

AutoCAD SHX Text

ROOM TEMP.:

AutoCAD SHX Text

INTERIOR AREA:

AutoCAD SHX Text Single

AutoCAD SHX Text 35%%dF

AutoCAD SHX Text 171 sq. ft.

AutoCAD SHX Text

1.5 hp.

AutoCAD SHX Text R-404A

AutoCAD SHX Text 115/208-230

AutoCAD SHX Text 60 hz.

AutoCAD SHX Text

20.6 MCA

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

MODEL NO.:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DRAWING NAME:

AutoCAD SHX Text

FORT WAYNE, INDIANA

AutoCAD SHX Text 1-800-752-7178

AutoCAD SHX Text Jennings Elementary HL1224 Quincy MI C

AutoCAD SHX Text

RLM

AutoCAD SHX Text

HL1224

AutoCAD SHX Text 3/16"=1'-0"

AutoCAD SHX Text 5-5-20

AutoCAD SHX Text

HORSEPOWER:

AutoCAD SHX Text

REFRIGERANT:

AutoCAD SHX Text

ELEC. SUPPLY

AutoCAD SHX Text

AMPERAGE:

AutoCAD SHX Text

CYCLE:

AutoCAD SHX Text

PHASE:

AutoCAD SHX Text

ROOM TEMP.:

AutoCAD SHX Text

INTERIOR AREA:

AutoCAD SHX Text Single

AutoCAD SHX Text -10%%dF

AutoCAD SHX Text 82 sq. ft.

AutoCAD SHX Text

2.25 hp.

AutoCAD SHX Text R-404A

AutoCAD SHX Text 115/208-230

AutoCAD SHX Text 60 hz.

AutoCAD SHX Text

27.2 MCA

AutoCAD SHX Text L

AutoCAD SHX Text C

AutoCAD SHX Text 36" x 79" x 79"

AutoCAD SHX Text L

AutoCAD SHX Text C

AutoCAD SHX Text 36" x 79" x 79"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 4-Tier

AutoCAD SHX Text 3-Tier

AutoCAD SHX Text 3-Tier

AutoCAD SHX Text

FFAL-022Z-CFV

AutoCAD SHX Text

DOOR RAMP

AutoCAD SHX Text

LED LIGHT

AutoCAD SHX Text

LED LIGHT

AutoCAD SHX Text

LED LIGHT

Sheets and Views
Model

File details come from the government source that posted it. Updated .